The communication card group contains objects for the bus repeater card (BRC) and the network bus controller (NBC).
The system maintains a listing of BRC hardware connections. When the system is equipped with redundant BRCs, the BRC listing indicates which BRC pair is active and which is standby. All BRCs in the system must be entered in the system database before you configure them. A BRC is identified by its Rack, Level, and Slot (R,L,S) hardware address.
A BRC pair consists of a master BRC (MBRC) and a secondary BRC (SBRC). The MBRC must reside in the Master Port Subrack usually in Rack 1, Level 1. The SBRC resides in either Slot 1 or 2 of an Expansion Port Subrack. The system uses this BRC pair to extend the communications bus from the Master Port Subrack to the Expansion Port Subrack. A BRC pair is required for each Expansion Port Subrack in the system. BRC redundancy requires a second pair for each subrack.
The MBRC and SBRC are physically connected by a cable (refer to the Cisco VCO/4K Hardware Installation Guide) and logically connected (in the software) using the objects in the BRC table. Both the physical and logical connections must be made for the system to establish communications to an Expansion Port Subrack.
Consider the following when configuring BRCs:
{comm 1}
Description
The BRC configuration table.
Object Identifier
1.3.6.1.4.1.886.1.6.1
Data Type
Sequence of BrcEntry
Access Policy
Not accessible
Status
Mandatory
{brcTable 1}
Description
An object in the BRC configuration table.
Object Identifier
1.3.6.1.4.1.886.1.6.1.1
Data Type
BrcEntry
Access Policy
Not accessible
Status
Mandatory
Index
{brcIndex}
Sequence
brcIndex | CardIndex |
brcRack | Integer |
brcLevel | Integer |
brcSlot | Integer |
brcStatus | Integer |
brcType | Integer |
brcRevVer | Display String |
brcPhyAdd | Integer |
brcConn | Integer |
brcDisConn | Integer |
brcMode | Integer |
brcRedMasterIndex | CardIndex |
brcAlarm | Integer |
brcErrorStatus | Integer |
brcOwnerString | OwnerString |
brcEntryStatus | EntryStatus |
{brcEntry 1}
Description
Identifies an object in the BRC table. This object contains the physical location (hardware address) of the card to which this port is attached. The index object lists the rack (R), the level (L), and the slot (S) where the card resides.
Object Identifier
1.3.6.1.4.1.886.1.6.1.1.1
Data Type
CardIndex
Access Policy
Read only
Status
Mandatory
{brcEntry 2}
Description
The rack (R) where the card resides.
Object Identifier
1.3.6.1.4.1.886.1.6.1.1.2
Data Type
Integer
Access Policy
Read only
Status
Mandatory
{brcEntry 3}
Description
The level (L) where the card resides.
Object Identifier
1.3.6.1.4.1.886.1.6.1.1.3
Data Type
Integer
Access Policy
Read only
Status
Mandatory
{brcEntry 4}
Description
The slot (S) where the card resides.
Object Identifier
1.3.6.1.4.1.886.1.6.1.1.4
Data Type
Integer
Access Policy
Read only
Status
Mandatory
{brcEntry 5}
Description
Indicates the current status of the card.
Object Identifier
1.3.6.1.4.1.886.1.6.1.1.5
Data Type
Integer. The valid numerical and string values are shown in the following table:
Value | String | Meaning |
---|---|---|
1 | active1 | Ports on this card can be involved in active calls and can be allocated to new calls. |
4 | outOfService | No ports on this card can be involved in active calls. No ports are allocated to new calls. |
5 | standby | Valid for one of the two NBC cards in redundant systems only. Also valid for one or more DTG cards in either a redundant or nonredundant system or BRCs. |
6 | campedOn | (diagnostic state) |
7 | payloadLoopback | (diagnostic state) |
8 | remoteLoopback | (diagnostic state) |
1The agent might take as long as 10 seconds to put a card into the Active state. |
Access Policy
Read-write
Status
Mandatory
{brcEntry 6}
Description
Indicates the type of card. In this table the type is a BRC card (the value is always 14).
Object Identifier
1.3.6.1.4.1.886.1.6.1.1.6
Data Type
Integer
Access Policy
Read only
Status
Mandatory
{brcEntry 7}
Description
Indicates the version and the revision level numbers of the firmware installed on the card. Use this object to verify the firmware revisions for all network interface and service circuit cards are at the current level.
Object Identifier
1.3.6.1.4.1.886.1.6.1.1.7
Data Type
DisplayString. Length of the display string is from 1 to 5 characters.
Access Policy
Read only
Status
Mandatory
{brcEntry 8}
Description
The physical address of this card. The address is assigned by the system. You cannot assign or modify this address.
Object Identifier
1.3.6.1.4.1.886.1.6.1.1.8
Data Type
Integer
Access Policy
Read only
Status
Mandatory
{brcEntry 9}
Description
Connects two BRCs that are in a master/slave mode. If either of the two cards is already connected, the connect BRC operation fails and the management station disconnects the cards using the brcDisConn object. An SNMP GetRequest on this object when no BRCs are connected returns a 0 value.
Object Identifier
1.3.6.1.4.1.886.1.6.1.1.9
Data Type
Integer
Access Policy
Read-write
Status
Mandatory
{brcEntry 10}
Description
Disconnects an already existing BRC pair. To disconnect a pair, you need to set this object to the same value set in the brcConn object. An SNMP GetRequest on this object returns a NoSuchName error message.
Object Identifier
1.3.6.1.4.1.886.1.6.1.1.10
Data Type
Integer
Access Policy
Read-write
Status
Mandatory
{brcEntry 11}
Description
Indicates whether the card is in the master (1) or slave (2) mode.
Object Identifier
1.3.6.1.4.1.886.1.6.1.1.11
Data Type
Integer. The two values are 1 (master) and 2 (slave).
Access Policy
Read only
Status
Mandatory
{brcEntry 12}
Description
Contains the location of the Master BRC that is associated with the same expansion port subrack as the Master BRC for this BRC pair for systems with redundant BRCs. If there is no redundant BRC, this object contains a zero (0).
Object Identifier
1.3.6.1.4.1.886.1.6.1.1.12
Data Type
CardIndex
Access Policy
Read only
Status
Mandatory
{brcEntry 13}
Description
Tracks which alarms are active on this card.
Object Identifier
1.3.6.1.4.1.886.1.6.1.1.13
Data Type
Integer. The valid values and their meanings are shown in the following table:
Value | String |
---|---|
1 | cardFailureMinor |
2 | portFailureMinor |
3 | cardAndPortFailureMinor |
Access Policy
Read only
Status
Mandatory
{brcEntry 14}
Description
Registers the last error that occurred on this card. For further information on card error messages, see "Card Error Messages".
Object Identifier
1.3.6.1.4.1.886.1.6.1.1.14
Data Type
Integer. The possible values and their meanings are shown in the following table:
Value | String |
---|---|
1536 | cannotConnectBRCsOnSameSubrack |
1537 | oneBrcMustBeInMasterSubrack |
1538 | brcNotDefinedInThisSlot |
1545 | invalidRackLevelCombination |
1546 | invalidCardAddress |
1547 | masterBrcAlreadyConnected |
1548 | destinationBrcAlreadyConnected |
Access Policy
Read only
Status
Mandatory
{brcEntry 15}
Description
The entity that configured this object and is therefore using the assigned resources.
Object Identifier
1.3.6.1.4.1.886.1.6.1.1.15
Data Type
OwnerString
Access Policy
Read-write
Status
Mandatory
{brcEntry 16}
Description
The status of this BRC object.
Object Identifier
1.3.6.1.4.1.886.1.6.1.1.16
Data Type
EntryStatus
Access Policy
Read-write
Status
Mandatory
{brcEntry 17}
Description
Version/revision of the card download file
Object Identifier
1.3.6.1.4.1.886.1.6.1.1.17
Data Type
DisplayString (SIZE (1..4))
Access Policy
Read only
Status
Mandatory
{brcEntry 18}
Description
The upgrade state of this bus repeater card entry.
Object Identifier
1.3.6.1.4.1.886.1.6.1.1.18
Data Type
UpgradeState
Access Policy
Read only
Status
Mandatory
{comm 2}
Description
The time, displayed in hundredths of a second, since the brcTable was last modified. Helps NMS application developers determine the polling of the agent parameters.
Object Identifier
1.3.6.1.4.1.886.1.6.2
Data Type
TimeTicks
Access Policy
Read only
Status
Mandatory
The Network Bus Controller (NBC) is a special control circuit card that resides only in Slot 1 or 2 of the Master port subrack. The NBC drives the communication bus and time slot address bus, and generates the system clocks. The NBC also provides the data communication path between the System Controller and the circuit cards in the master and expansion port subracks.
{comm 4}
Description
The NBC configuration table.
Object Identifier
1.3.6.1.4.1.886.1.6.4
Data Type
Sequence of NbcEntry
Access Policy
Not accessible
Status
Mandatory
{nbcTable 1}
Description
An entry in the NBC configuration table.
Object Identifier
1.3.6.1.4.1.886.1.6.4.1
Data Type
NbcEntry
Access Policy
Not accessible
Status
Mandatory
Index
{nbcIndex}
Sequence
nbcIndex | CardIndex |
nbcRack | Integer |
nbcLevel | Integer |
nbcSlot | Integer |
nbcStatus | Integer |
nbcType | Integer |
nbcRevVer | Display String |
nbcPhyAdd | Integer |
nbcAlarm | Integer |
nbcErrorStatus | Integer |
nbcOwnerString | OwnerString |
nbcEntryStatus | EntryStatus |
{nbcEntry 1}
Description
Identifies an object in the NBC card table. It corresponds to the physical location of the card and is a function of the rack (R), the level (L), and the slot (S) where the card resides.
Object Identifier
1.3.6.1.4.1.886.1.6.4.1.1
Data Type
CardIndex
Access Policy
Read only
Status
Mandatory
{nbcEntry 2}
Description
The rack (R) where the card resides.
Object Identifier
1.3.6.1.4.1.886.1.6.4.1.2
Data Type
Integer
Access Policy
Read only
Status
Mandatory
{nbcEntry 3}
Description
The level (L) where the card resides.
Object Identifier
1.3.6.1.4.1.886.1.6.4.1.3
Data Type
Integer
Access Policy
Read only
Status
Mandatory
{nbcEntry 4}
Description
The slot (S) where the card resides.
Object Identifier
1.3.6.1.4.1.886.1.6.4.1.4
Data Type
Integer
Access Policy
Read only
Status
Mandatory
{nbcEntry 5}
Description
Indicates the current status of the card. You cannot change the status of the NBC card.
Object Identifier
1.3.6.1.4.1.886.1.6.4.1.5
Data Type
Integer. The valid numerical and string values are shown in the following table:
Value | String | Meaning |
---|---|---|
1 | active | Indicates the card is active. |
4 | outOfService | Indicates the card is out of service. |
5 | standby | Valid for one of the two NBC cards in redundant systems only. Also valid for one or more DTG cards in either a redundant or nonredundant system or BRCs. |
Access Policy
Read only
Status
Mandatory
{nbcEntry 6}
Description
Indicates the type of card. In this table the card is an NBC card. For an NBC card, this value is always 13.
Object Identifier
1.3.6.1.4.1.886.1.6.4.1.6
Data Type
Integer
Access Policy
Read only
Status
Mandatory
{nbcEntry 7}
Description
Indicates the version number and the revision level numbers for the firmware installed on this card. Use these numbers to verify that firmware revisions for all network interface and service circuit cards are at the current level.
Object Identifier
1.3.6.1.4.1.886.1.6.4.1.7
Data Type
DisplayString. Length of the display string is from 1 to 5 characters.
Access Policy
Read only
Status
Mandatory
{nbcEntry 8}
Description
The physical address of this card. The address is assigned by the VCO system. You cannot assign the address and you cannot modify it.
Object Identifier
1.3.6.1.4.1.886.1.6.4.1.8
Data Type
Integer
Access Policy
Read only
Status
Mandatory
{nbcEntry 9}
Description
Tracks which alarms are active on this card.
Object Identifier
1.3.6.1.4.1.886.1.6.4.1.9
Data Type
Integer. The valid values and their meanings are shown in the following table:
Value | String |
---|---|
1 | cardFailureMinor |
2 | portFailureMinor |
3 | cardAndPortFailureMinor |
Access Policy
Read only
Status
Mandatory
{nbcEntry 10}
Description
Registers the last error that occurred on this card. For a list of the card error messages, see "Card Error Messages".
Object Identifier
1.3.6.1.4.1.886.1.6.4.1.10
Data Type
Integer
Access Policy
Read only
Status
Mandatory
{nbcEntry 11}
Description
The entity that configured this object and is therefore using the resources assigned to it.
Object Identifier
1.3.6.1.4.1.886.1.6.4.1.11
Data Type
OwnerString
Access Policy
Read-write
Status
Mandatory
{nbcEntry 12}
Description
The status of this NBC card entry. Adding or deleting an NBC card in location 2 also adds the DTG card. The nbcEntryStatus must be set to valid after the card is created.
To modify the attributes of the DTG card in location 1 or 2, use the dtgCardEntryStatus and dtgPortEntryStatus objects.
Object Identifier
1.3.6.1.4.1.886.1.6.4.1.12
Data Type
EntryStatus
Access Policy
Read-write
Status
Mandatory
{nbcEntry 13}
Description
Version/revision of the card download file.
Object Identifier
1.3.6.1.4.1.886.1.6.4.1.13
Data Type
DisplayString (size 1...4)
Access Policy
Read only
Status
Mandatory
{nbcEntry 14}
Description
The upgrade state of this network bus controller card entry.
Object Identifier
1.3.6.1.4.1.886.1.6.4.1.14
Data Type
UpgradeState
Access Policy
Read only
Status
Mandatory
{comm 5}
Description
The time, displayed in hundredths of a second, since the nbcTable was last modified. Helps NMS application developers determine the polling of the agent parameters.
Object Identifier
1.3.6.1.4.1.886.1.6.5
Data Type
TimeTicks
Access Policy
Read only
Status
Mandatory
Posted: Sat Sep 28 11:08:41 PDT 2002
All contents are Copyright © 1992--2002 Cisco Systems, Inc. All rights reserved.