This chapter describes how to make adjustments to the router interfaces, and how to enable loopback tests. The tasks in this chapter include:
To adjust or test an interface, you must be in the configuration command collection mode. To enter this mode, type the EXEC command configure at the EXEC prompt. Once in the command collection mode, start configuring the interface by entering the interface command.
A summary of the interface subcommands described in this chapter is included at the end of the chapter.
The following sections describe adjustments that can be made to serial interfaces.
Since the MCI and SCI interface cards can send back-to-back data packets over serial interfaces faster than some hosts can receive them, you can specify a minimum dead-time after transmitting a packet using the following subcommand which is especially useful for serial interfaces. Use the transmitter-delay interface subcommands to do this. The full syntax of the command follows.
transmitter-delay microsecondsThe argument microseconds specifies the approximate number of microseconds of minimum delay after transmitting a packet. The default value is zero; the no transmitter-delay command restores this default.
This command specifies a delay of 300 microseconds on interface serial 0.
interface serial 0
transmitter-delay 300
For the serial interface on the IGS router and the High-Speed Serial Interface (HSSI) on the AGS+, the command is specified as follows:
transmitter-delay hdlc-flagsThe argument hdlc-flags causes a minimum number of HDLC flags to be sent between each packet. The valid range on the IGS is 2 to 62; the valid range on the HSSI is 2 to 128000. The default is zero.
The pulse-time interface subcommand enables pulsing DTR signals on the Cisco serial interfaces. The full syntax of the command follows.
pulse-time secondsThe argument seconds specifies the interval.When the serial line protocol goes down (for example, because of loss of synchronization), the interface hardware is reset and the DTR signal is held inactive for at least the specified interval. This function is useful for handling encrypting or other similar devices that use the toggling of the DTR signal to resynchronize.
This command is also used to specify the time allowed for a modem to recognize that DTR has dropped so that the modem can disconnect the call.
The default interval is zero seconds, which is restored by the no pulse-time command.
This command enables DTR pulse signals for three seconds on interface serial 2.
interface serial 2
pulse-time 3
You may configure the clock rate on the serial interface of the SCI and MCI cards to an acceptable bit rate using the clockrate interface subcommand. The full syntax is as follows:
clockrate speedThe argument speed is the desired clock rate, and may be one of any of the rates in Table 1-1.
1200 | 2400 | 4800 |
9600 | 19200 | 38400 |
56000 | 64000 | 72000 |
125000 | 148000 | 500000 |
800000 | 1000000 | 1300000 |
2000000 | 4000000 |
|
Be aware that the fastest speeds may not work if your cable is too long, and that speeds faster than 148,000 bits per second are too fast for RS-232 signaling. Cisco recommends you only use the synchronous serial RS-232 signal at speeds up to 64,000 bits per second. To permit a faster speed, use an RS-449 or V.35 applique.
Use the no clockrate command to remove the clock rate if you change the interface from a DCE to a DTE device.
These sample commands set the clock rate on the first serial interface to 64,000 bits per second.
interface serial 0
clockrate 64000
The following sections describe adjustments that apply to all interface types.
The normal operation of the network server allows the switching operations to use as much of the central processor as is required. If the network is running unusually heavy loads that do not allow the processor the time to handle the routing protocols, give priority to the system process scheduler using the scheduler-interval global configuration command. The full command syntax follows:
scheduler-interval millisecondsThe scheduler-interval command controls the maximum amount of time that may elapse without running the lowest priority system processes. The minimum interval that may be specified is 500 milliseconds; there is no maximum value. The default is to allow high-priority operations to use as much of the central processor as needed. The no scheduler-interval command restores that default.
This command changes the low-priority process schedule to an interval of 750 milliseconds.
scheduler-interval 750
Priority output queuing is a mechanism that allows the administrator to set priorities on the type of traffic passing through the network. It is a mechanism for prioritizing packets transmitted on an interface. Packets are classified according to various criteria, including protocol and subprotocol type, and then queued on one of four output queues.
When the network server is ready to transmit a packet, it scans the priority queues in order, from highest to lowest, to find the highest priority packet. After that packet is completely transmitted, the network server scans the priority queues again. If a priority output queue fills up, packets will be dropped and, for protocols such as IP and CLNS, quench indications will be sent to the original transmitter.
Although priority queuing may be enabled for any interface, the intended application was for low bandwidth, congested serial interfaces.
Cisco's priority output queuing mechanism allows traffic control based on protocol or interface type. Commands are also offered to set the size of the queue, and defaults for what happens to packets that are not defined by priority output queue rules.
The priority output queuing mechanism can be used to manage traffic from all networking protocols and from bridges. Additional fine tuning is available for IP, and for setting boundaries on the packet size.
There are four priority queues--high, medium, normal, low--listed in order from highest to lowest priority.
Keepalives sourced by the network server are always assigned to the high priority queue; all other management traffic (such as IGRP updates) must be configured. Packets that are not classified by the priority list mechanism are assigned to the normal queue.
A priority list is a set of rules that describes how packets should be assigned to priority queues. A priority list may also describe a default priority or the queue size limits of the various priority queues.
Use the priority-list global configuration command to establish queuing priorities based upon the protocol type. The full syntax of this command follows:
priority-list list protocol protocol-name queue-keyword [args]The argument list is an arbitrary integer between one and ten that identifies the priority list selected by the user.
The keyword protocol is used with the argument protocol-name to specify the protocol you are using, and is one of the following: ip, pup, chaos, xns, decnet, appletalk, clns, novell, apollo, vines, rsrb (for remote source-route bridging traffic), stun (for Serial Tunneling), or bridge (for transparent bridging traffic).
The argument queue-keyword is a priority queue name, one of high, medium, normal, or low.
Optional arguments (args) may be specified, depending on the protocol-name keyword, as follows:
Service | Port |
---|---|
Telnet | 23 |
SMTP | 25 |
Service | Port |
---|---|
TFTP | 69 |
NFS | 2049 |
SNMP | 161 |
RPC | 111 |
DNS | 53 |
Use the no priority-list global configuration command followed by the appropriate list argument and the protocol keyword to remove a priority list entry assigned by protocol type.
This command assigns one as the arbitrary priority list number, specifies DECnet as the protocol type, and assigns a high priority to the packets transmitted on this interface:
priority-list 1 protocol decnet high
When classifying a packet, the system searches the list of rules specified by priority-list commands for a matching protocol type. When a match is found, the packet is assigned to the appropriate queue. The list is searched in the order it is specified and the first matching rule terminates the search.
This command assigns a medium priority level to every DECnet packet with a size greater than 200 bytes.
priority-list 2 protocol decnet medium gt 200
This command assigns a medium priority level to every DECnet packet with a size less than 200 bytes:
priority-list 4 protocol decnet medium lt 200
This command assigns a high priority to traffic that matches IP access list 10:
priority-list 1 protocol ip high list 10
This command assigns a medium priority level to Telnet packets:
priority-list 4 protocol ip medium tcp 23
This command assigns a medium priority level to UDP Domain Name service packets:
priority-list 4 protocol ip medium udp 53
This command assigns a high priority to traffic that matches Ethernet type code access list 201:
priority-list 1 protocol bridge high list 201
When using multiple rules for a single protocol, remember that the order of the rules matters.
Use this variation of the priority-list global configuration command to establish queuing priorities on packets entering from a given interface (full syntax follows):
priority-list list interface interface-name queue-keywordThe argument list is an arbitrary integer between one and ten that identifies the priority list selected by the user.
The keyword interface applies to the priority queuing mechanism to packets arriving from an interface. The argument interface-name specifies the name of the interface.
The argument queue-keyword is a priority queue name, one of high, medium, normal, or low.
Use the no priority-list command with the appropriate arguments to remove an entry from the list.
The following sample command sets any packet type entering on interface Ethernet 2 to a medium priority:
priority-list 3 interface ethernet 2 medium
Use the following global configuration command to assign a priority queue for those packets that did not match any other rule in the priority list:
priority-list list default queue-keywordThe normal queue is assumed if you use the no form of the command, .
Use this variation of the priority-list global configuration command to specify the maximum number of packets that may be waiting in each of the priority queues (full syntax shown):
priority-list list queue-limit high-limit medium-limit normal-limit low-limitIf a priority queue overflows, excess packets are discarded and quench messages may be sent, if appropriate, for the protocol. The default queue-limit arguments are 20 packets for the high priority queue, 40 for medium, 60 for normal, and 80 for low.
The normal queue is assumed if you use the no form of the command.
The following is a sample of a priority list, including the access list referenced by one of the priority list rules.
priority-list 1 protocol bridge high list 201
priority-list 1 protocol ip medium
priority-list 1 protocol decnet medium
priority-list 1 default low
priority-list 1 queue-limit 20 20 20 10
!
access-list 201 permit 0x6004 0x0000
Bridged traffic that matches access list 201 is given high priority. Because type code 6004 is the Local Area Transport (LAT), this rule assigns LAT traffic high priority. IP and DECnet traffic are given medium priority, and everything else is given low priority. In this instance, the network administrator has assigned queue limits of 20 packets for every queue except the low priority queue, which is limited to 10 untransmitted packets.
Use the priority-group interface subcommand to assign the specified priority list to an interface.
priority-group listThe argument list is the priority list number assigned to the interface. Only one list can be assigned per interface. The no version of the command removes the specified priority-group assignment.
This example causes packets exiting interface serial 0 to be classified by priority list 1.
interface serial 0
priority-group 1
When priority queuing is enabled on an interface, the EXEC command show interfaces displays information about the input and output queues. This information is a triplet of numbers: the first is the number of packets currently in the queue, the second is the maximum number of packets permitted in the queue, and the third is the number of packets discarded because the queue is full.
Input queue: 0/75/4 (size/max/drops); Total output drops: 0
Output queue: high 0/20/0, medium 0/40/00, normal 0/60/0, low 0/80/0
The total output drops number is the sum of the discarded numbers from the output queues, plus the count of packets discarded before being prioritized, or because of fast-switching activity.
The interface subcommand tx-queue-limit controls the size of the transmit queue available to a specified interface on the MCI and SCI cards themselves. The command syntax follows:
tx-queue-limit numberThis command should be used only under the guidance of technical support representatives. Number is the number of packets that may be queued for transmission on the card for the specified interface.
tx-queue-limit 5
Each network interface in a network server has a hold-queue limit. This limit is the number of data packets that the interface can store in its hold queue before rejecting new packets. When the interface empties one or more packets from the hold queue, the interface can accept new packets again.
To specify the hold-queue limit of an interface, use the hold-queue interface subcommand. Its full syntax is as follows:
hold-queue length {in|out}The argument length is the maximum number of packets in the queue. The in keyword specifies the input queue; the out keyword specifies the output queue.
The input hold queue prevents a single interface from flooding the network server with too many input packets. Further input packets are discarded if the interface has too many input packets outstanding in the system. The default input hold queue is 75 packets. The default output hold-queue limit is 40 packets. This limit prevents a malfunctioning interface from consuming an excessive amount of memory.
The no hold-queue command with the appropriate keyword restores the default values for an interface. There is no fixed upper limit to a queue size.
If priority output queueing is being used, the length of the four output queues is set using the priority-list global configuration command. The hold-queue command cannot be used to set an output hold queue length in this situation.
For slow links, use a small output hold-queue limit. This approach prevents storing packets at a rate that exceeds the transmission capability of the link. For fast links, use a large output hold-queue limit. A fast link may be busy for a short time (and thus require the hold queue), but can empty the output hold queue quickly when capacity returns.
To display the current hold queue setting and the number of packets discarded because of hold queue overflows, use the EXEC command show interfaces.
Higher-level protocols may use bandwidth information to make operating decisions. For example, IGRP uses the minimum path bandwidth to determine a routing metric. The TCP protocol adjusts initial retransmission parameters based on the apparent bandwidth of the outgoing interface.
To set a bandwidth value for an interface, use the bandwidth interface subcommand. Its full syntax follows:
bandwidth kilobitsThe argument kilobits specifies the intended bandwidth in kilobits per second. For a full bandwidth DS3, enter the value 44736. Default bandwidth values are set during start up and can be displayed with the EXEC command show interfaces.
The bandwidth subcommand sets an informational parameter only; you cannot adjust the actual bandwidth of an interface with this subcommand. For some media, such as Ethernet, the bandwidth is fixed; for other media, such as serial lines, you can change the actual bandwidth by adjusting hardware. For both classes of media, you can use the bandwidth subcommand to communicate the current bandwidth to the higher-level protocols.
Use the no bandwidth command to restore the default values.
Higher-level protocols may use delay information to make operating decisions. For example, IGRP can use delay information to differentiate between a satellite link and a land link.
To set a delay value for an interface, use the delay interface subcommand. The full syntax of this command follows.
delay tens-of-microsecondsThe argument tens-of-microseconds specifies the delay for an interface or network segment in tens of microseconds. Default delay values may be displayed with the EXEC command show interfaces. The no delay command restores the default.
The Cisco interface software provides a mechanism for protection against packet overload and resultant recount errors on the MCI interface cards. Set this mechanism using the error-threshold interface subcommand, as follows:
error-threshold millisecondsThe argument milliseconds is the frequency at which the error recount will be set. The default value is 1000 milliseconds.
These commands set the error recount threshold on Ethernet interface 2 to 10,000
milliseconds.
interface ethernet 2
error-threshold 10000
Each interface has a default maximum packet size or maximum transmission unit (MTU) size. This number generally defaults to the largest size possible for that type interface. On serial interfaces, the MTU size varies, but cannot be set smaller than 64 bytes. You can adjust the MTU using the mtu interface subcommand:
mtu bytesThe arguments bytes is the desired size in bytes. The no mtu command restores this value to its original default value. Table 1-4 lists default MTU values according to media type.
Media Type | Default MTU |
---|---|
Ethernet | 1500 |
Serial | 1500 |
UltraNet (ULA) | 4500 |
Token Ring | 4464 |
FDDI | 4470 |
HSSI (HSA) | 4470 |
The following is an example of specifying the MTU on serial port to 300 bytes:
interface serial 1
mtu 1000
The Cisco software provides a loopback test to detect and distinguish equipment malfunctions between line and modem or CSU/DSU (Channel Service Unit/Digital Service Unit) problems on the network server. If correct data transmission is not possible when an interface is in loopback mode, the interface is the source of the problem. The DSU may have similar loopback functions you can use to isolate the problem, if the interface loopback tests passes. If the device does not support local loopback, then this function will have no effect.
You can specify hardware loopback tests on the Cisco Ethernet and serial interfaces, and all Token Ring interfaces except the CSC-R 4 megabit card that are attached to CSU/DSUs, and that support the local loopback signal. The CSU/DSU acts as a DCE device; the Cisco router as a DTE device. The local loopback test generates a CSU loop--a signal that goes through the CSU/DSU to the line, then back through the CSU/DSU to the router.
The ping command can also be useful during loopback operation; it is described in the section on "Testing Connectivity with the Ping Command" in the "Managing and Monitoring the System" chapter.
The following sections describe the various loopback tests available for the supported interfaces.
The HSSI supports the loopback test from the router to any of the following:
These concepts are illustrated in Figure 1-1.
The subcommands to enable these tests are described next. In the following subcommands, the loopback command with no argument defaults to the loopback applique command.
To start loopback operation, use the loopback interface subcommand with the appropriate keyword. To restore an interface in loopback mode to normal operation, use the no loopback interface subcommand with the appropriate keyword. Each keyword variation of the loopback subcommand is described in the following sections.
Use the following subcommand to configure an internal loop on the HSSI applique. The full syntax of this subcommand follows:
loopback appliqueOnce enabled, the subcommand loops the packets on the applique, thereby establishing a loopback inside the Cisco router. This subcommand is useful for sending pings to yourself to check functionality of the applique. The HSSI applique (HSA card) uses an internal 44.736 MHz crystal clock during the applique loopback to drive its internal circuits. See the document HSSI Specification, available from Cisco Systems, for more information.
This subcommand is functionally equivalent to entering the loopback subcommand with no arguments; however, when the HSCI card is installed, the configuration displayed after the write terminal subcommand is entered will show loopback applique set. The no version of the subcommand disables this test.
Use the loopback dte subcommand to loop packets to DTE within the CSU/DSU at the DTE interface, when the device supports this function. The full syntax of this subcommand is:
loopback dteThis subcommand is useful for testing the DTE to DCE cable. The no version of the subcommand disables this test
Use the loopback line subcommand to loop the packets completely through the
CSU/DSU to configure a CSU loop, when the device supports this feature. The full syntax of this subcommand follows:
This subcommand is used for testing the DCE device (CSU/DSU) itself. The no version of the subcommand disables this test
If you want to loop the packets through the CSU/DSU, over the DS3 link, and to the remote CSU/DSU and back, use the loopback remote subcommand. Its full syntax follows:
loopback remoteThis is applicable only when the device supports the remote function and it is used for testing the data communications channels. The loopback is usually performed at the line port, as opposed to the DTE port, of the remote CSU/DSU.
To show interfaces currently in loopback operation, use the EXEC command show interfaces. The no version of the subcommand disables this test
The HSA applique (on the HSSI), contains an LED that indicates the LA, LB, and LC signals transiting through the devices. The CSU/DSU uses the LC signal to request a loopback from the router. The CSU/DSU may want to do this so that its own network management diagnostics can independently check the integrity of the connection between the CSU/DSU and the Cisco router.
By default, this feature is enabled on the Cisco router to support those CSU/DSUs that support this function. To enable and disable a two-way, internal, and external loopback request on HSSI from the CSU/DSU, use these commands:
hssi external-loop-requestWhen the CSU/DSU asserts the LC signal and the Cisco router enables the external loopback, the connection is blocked by the loopback, and the router no longer has access to the data communication channel. Figure 1-2 illustrates the extent of the signal during an external loopback request.
Cisco provides a useful diagnostic that allows fault isolation of possible defects on the HSCI card. This diagnostic is not part of the normal system diagnostics, but is offered to help technicians test for controller defects at installation or when the system is upgraded. The diagnostic involves recabling of the HSCI card and then entering a diagnostic script. The procedures to perform this diagnostic are described in the Cisco publication Modular Products Hardware Installation and Reference.
For users with UltraNet connections, the loopback function is enabled with the loopback interface subcommand (full syntax follows):
loopbackEnabling the function places a two-way, internal, and external loopback on the ULA applique, as seen in Figure 1-3.
Data being transmitted from the router is returned to the router, and incoming data from outside is transmitted back outside.
The MCI and SCI serial interface cards support the loopback function when a CSU/DSU or equivalent device is attached to the router. Use the loopback interface subcommand to enable loopback on the interface. The full syntax of this subcommand follows:
loopbackThe loopback interface subcommand loops the packets through the CSU/DSU to configure a CSU loop, when the device supports this feature. The no loopback subcommand disables the function.
Cisco-designed Ethernet interfaces may also be placed into loopback mode. During loopback operation, the interface receives back every packet it sends. Loopback operation has the additional effect of disconnecting network server functionality from the network. Use these commands to enable or disable the loopback test:
loopbackThe Cisco network server provides an Ethernet loopback server that supports Xerox, Intel, and DEC systems specified by the "blue book," a joint specification written by Xerox, Digital Equipment Corporation, and Intel that defines the Ethernet protocol. The loopback server responds to forward data loopback messages sent either to the server's MAC address, or to the broadcast address. Currently, the Ethernet loopback server does not respond to the loopback assistance multicast address.
Use the Ethernet loopback server to test communications between Cisco internetworking products and DEC systems that do not support the IP ping command, such as DECnet-only VMS systems.
To originate a loop test on your VMS system with a Cisco server, use the DEC Network Control Program (NCP) command Loop Circuit. For more information about the Loop Circuit command, consult the DECnet VAX documentation. Cisco network servers support all options that can be specified by the VMS hosts.
The Cisco FDDI (CSC-FCI) may also be placed into loopback mode. During loopback operation, the interface receives back every packet it sends. Loopback operation has the additional effect of disconnecting network server functionality from the network. Use these commands to enable or disable the loopback test:
loopbackAll of Cisco's Token Ring interface cards (except the 4 Mbps CSC-R card) may also be placed into loopback mode. During loopback operation, the interface receives back every packet it sends. Loopback operation has the additional effect of disconnecting network server functionality from the network. Use these commands to enable or disable loopback on the interface:
loopbackThis section provides an alphabetical list of all the global configuration commands described in this chapter.
[no] priority-list list default queue-keyword
Assigns a priority queue for those packets that did not match any other rule in the priority list. If no default or the no form of the command is specified, the normal queue is assumed.
[no] priority-list list interface interface-name queue-keyword
Sets up priority queuing on the specified interface. The keyword interface applies to the priority queuing mechanism to an interface. The argument interface-name specifies the name of the interface. The arguments list and queue-keyword are described in the section "Assigning Priority by Interface Type." The no form of the command removes the item from the list.
[no] priority-list list protocol protocol-name queue-keyword [args]
Sets up priority queuing on the specified interface. The keyword protocol applies to the priority queuing mechanism to a protocol. The argument protocol-name specifies the name of the protocol. The arguments list, queue-keyword, and the optional args are described in the section "Assigning Priority by Protocol Type." The no form of the command removes the item from the list.
[no] priority-list list queue-limit high-limit medium-limit normal-limit low-limit
Specifies the maximum number of packets that may be waiting in each of the priority queues. If a priority queue overflows, excess packets are discarded and quench messages may be sent, if appropriate, for the protocol. The no form of the command resets all four queue sizes to their default values as follows: high-limit = 20; medium-limit = 40; normal-limit = 60; low-limit = 80.
[no] scheduler-interval milliseconds
Controls the maximum amount of time that may elapse without running the lowest priority system processes. The minimum interval that may be specified is 500 milliseconds; there is no maximum value. The default is to allow high priority operations to use as much of the central processor as needed. The no scheduler-interval command restores that default.
This section provides an alphabetical list of all the interface commands described in this chapter.
[no] bandwidth kilobits
Sets a bandwidth value for an interface. The argument kilobits specifies the intended bandwidth in kilobits per second. Default bandwidth values are set during start up and can be displayed with the EXEC command show interfaces. This is a routing parameter only; it does not affect the physical interface. The no form of the subcommand restores the default.
[no] clockrate speed
Configures the clock rate on the serial interface of the SCI and MCI cards to an acceptable bit rate. The argument speed is the desired clock rate in bits per second. The no form removes the subcommand from the configuration.
[no] delay tens-of-microseconds
Sets a delay value for an interface. The argument tens-of-microseconds specifies the delay for an interface or network segment in tens of microseconds. Default delay values may be displayed with the EXEC command show interfaces. The no form of the subcommand restores the default.
error-threshold milliseconds
Sets a mechanism for protection against packet overload and resultant recount errors on the MCI interface cards. The argument milliseconds is the frequency at which the error recount will be set. The default value is 1000 milliseconds.
hold-queue length {in|out}
no hold-queue {in|out}
Specifies the hold-queue limit of an interface. The argument length is the maximum number of packets in the queue. The in keyword specifies the input queue; the out keyword specifies the output queue. There is no fixed upper limit to a queue size. The default for in is 75; the default for out is 40. The no keyword restores the default values for an interface.
[no] hssi external-loopback-request
Enables and disables an external loopback request on HSSI from the CSU/DSU. When the CSU/DSU asserts the LC signal and the Cisco router enables the external loopback, the connection is blocked by the loopback, and the router no longer has access to the data communication channel.
[no] loopback
On HSSI--Configures a two-way, internal, and external loopback on the the HSA applique of the specified interface.
On UltraNet--Configures a two-way, internal, and external loopback on the ULA applique of the specified interface.
On MCI and SCI serial cards--Loops the packets through the CSU/DSU to configure a "CSU loop," when the device supports this feature. This is similar to the loopback line subcommand on the HSSI.
On MCI and MEC Ethernet cards--Loops the packets at the interface within the router.
On the CSC-R16 card--Loops the packets at the interface within the router.
The no form of the subcommand disables the loopback test.
[no] loopback applique
Configures an internal loop on the HSSI (only). This subcommand is useful for sending pings to yourself to check functionality of the applique. Equivalent to the loopback test for HSSI.
The no form of the subcommand disables this test.
[no] loopback dte
Loops packets from the router out to the CSU/DSU and back. For use with HSSI connections only to check connectivity between the router and the CSU/DSU.
The no form of the subcommand disables this test.
[no] loopback line
Loops the packets through the CSU/DSU to configure a CSU loop. Loopback occurs on the line side of the CSU/DSU to test functionality of the CSU/DSU. For use with HSSI connections only.
[no] loopback remote
Loops the packets through the CSU/DSU, over the DS3 link and to the remote CSU/DSU. This is applicable only when the device supports the remote function. For use with HSSI connections only.
The no form of the subcommand disables this test.
[no] mtu bytes
Adjusts the maximum transmission unit (MTU).The arguments bytes is the desired size in bytes. The no mtu subcommand restores this value to its original default value.
[no] priority-group list
Assigns the specified priority group to an interface. The argument list is the priority list number assigned to the interface. The no version of this subcommand removes a specific priority-group assignment if it includes a list argument. It removes all priority-group assignments if specified without the list argument.
[no] pulse-time seconds
Enables pulsing DTR signals on the Cisco serial interfaces for a minimum interval of seconds. The no version of the subcommand disables pulsing.
[no] transmitter-delay microseconds
Specifies a minimum dead-time after transmitting a packet. The argument microseconds specifies the approximate number of microseconds of minimum delay after transmitting a packet. For MCI and SCI serial cards only. The no form of the subcommand restores the default value of zero microseconds.
[no] transmitter-delay hdlc-flags
Specify this subcommand syntax for the IGS router and the High Speed Serial Interface (HSSI) connector. The argument hdlc-flags causes a minimum of HDLC flags to be sent between each packet. The valid range on IGS is 2 to 62; valid range on HSSI is 2 to 128000. The no form of the subcommand restores the default value of zero flags.
|