The tables below describe the devices and software releases that QoS Policy Manager (QPM) 2.0(x) supports, and the QoS techniques you can use on the supported platforms. Please note that the information in the tables is subject to change, depending on specific devices and their QoS support.
Cisco IOS releases supported include 11.1, 11.2, 11.3, 11.1cc, 12.0, 12.1, 12.1(2)T, 12.1(5)T, and 12.1(2)E. In addition, a Cisco IOS mapping function is used to enable QPM 2.0(x) to support 12.1(5)T and 12.1(2)E QoS techniques included in later releases of IOS main (T or E train) software.
Note In QPM 2.0, 12.1(4)T appears as the mapped version for IOS version 12.1(5)T. The device and QoS support is the same as for 12.1(5)T. |
The tables below describe the QoS techniques that you can use with the devices and IOS software releases that QPM 2.0(x) supports.
Quality of Service Technique | Cisco Systems Device | IOS Software Release | |||
---|---|---|---|---|---|
11.1 | 11.2 | 11.3 | 11.1(cc) | ||
7500, 7200 | Supported | Supported | Supported | Supported | |
RSM (Catalyst 5000), 4700, 4500, 4000, 3600, 2500, 1600 | Supported | Supported | Supported | - | |
2600 | - | - | Supported | - | |
7100, RSM VIP, 7500 VIP | - | - | - | - | |
7500 VIP (uses DWRED) | - | - | - | Supported | |
7500, 7200, RSM (Catalyst 5000), 4700, 4500, 4000, 3600, 2500, 1600 | - | Supported | Supported | - | |
2600 | - | - | Supported | - | |
7100, RSM VIP | - | - | - | - | |
7500, 7200 | Supported | Supported | Supported | Supported | |
RSM (Catalyst 5000), 4700, 4500, 4000, 3600, 2500, 1600 | Supported | Supported | Supported | - | |
2600 | - | - | Supported | - | |
7100 | - | - | - | - | |
RSM VIP (uses FQ only) | - | - | - | - | |
7500 VIP (uses FQ only) | - | - | - | Supported | |
Distributed weighted fair queuing (DWFQ), fair queuing, and QoS group DWFQ | 7500 VIP | - | - | - | Supported |
7100, RSM VIP, RSM (Catalyst 5000), 4700, 4500, 3600, 4000, 2500 | - | - | - | - | |
Policy-based routing (PBR) (also called coloring or classification) | 7500, 7200, RSM (Catalyst 5000), 4700, 4500, 4000, 3600, 2500, 1600 | - | Supported | Supported | - |
2600 | - | - | Supported | - | |
7100, RSM VIP, 7500 VIP | - | - | - | - | |
7500, 7200, RSM (Catalyst 5000), 4700, 4500, 4000, 3600, 2500, 1600 | - | Supported | Supported | - | |
2600 | - | - | Supported | - | |
7100, RSM VIP, 7500 VIP | - | - | - | - | |
7500, 7200, RSM (Catalyst 5000), 4700, 4500, 4000, 3600, 2500, 1600 | - | Supported | Supported | - | |
2600 | - | - | Supported | - | |
7100, RSM VIP, 7500 VIP | - | - | - | - | |
7500, 7500 VIP, 7200 | - | - | - | Supported | |
RSM (Catalyst 5000), 4700, 4500, 4000, 3600, 2500, 1600, 2600, 7100, RSM VIP | - | - | - | - | |
7500, 7500 VIP, 7200, RSM (Catalyst 5000), 4700, 4500, 3600, 2600 | - | - | - | Supported | |
4000, 2500, 1600, 7100, RSM VIP | - | - | - | - | |
7500, 7200, 4700, 4500, 4000, 3600, 2600, 2500, 1600 | - | Supported | Supported | - | |
7100, RSM VIP, 7500 VIP | - | - | - | - | |
7500, 7200, 7100, RSM (Catalyst 5000), 4700, 4500, 4000, 3600, 2600, 2500, 1600 | - | Supported | Supported | - | |
RSM VIP, 7500 VIP | - | - | - | - | |
7500, 7200, 7100, RSM (Catalyst 5000), 4700, 4500, 4000, 3600, 2600, 2500, 1600 | - | - | Supported | - | |
RSM VIP, 7500 VIP | - | - | - | - | |
All IOS devices (except 8500) | Supported | Supported | Supported | Supported |
Quality of Service Technique | Cisco Systems Device | IOS Software Release | ||||
---|---|---|---|---|---|---|
12.0 | 12.1 | 12.1(2)E and later1 | 12.1(2)T | 12.1(5)T and later1 | ||
7500 | Supported | Supported | Supported | Supported | Supported | |
7200 | Supported | Supported | Supported | Supported | Supported | |
7100 | - | - | Supported | Supported | Supported | |
RSM (Catalyst 5000), 4700, 4500, 3600 | Supported | Supported | Supported | Supported | Supported | |
4000, 2600, 2500, 1600 | Supported | Supported | - | Supported | Supported | |
1750, 1720 | Supported | Supported | - | Supported | Supported | |
RSM VIP, 7500 VIP, MSFC FlexWAN | - | - | - | - | - | |
7500 | Supported | Supported | Supported | Supported | Supported | |
7200 | Supported | Supported | Supported | Supported | Supported | |
7100 | - | - | Supported | Supported | Supported | |
RSM (Catalyst 5000), 4700, 4500, 3600 | Supported | Supported | Supported | Supported | Supported | |
4000, 2600, 2500, 1600 | Supported | Supported | Supported | Supported | Supported | |
1750, 1720 | Supported | Supported | - | Supported | Supported | |
RSM VIP, 7500 VIP, MSFC FlexWAN | - | - | - | - | - | |
7500, 7500 VIP (uses DWRED) | Supported | Supported | Supported | Supported | Supported | |
7200 | Supported | Supported | Supported | Supported | Supported | |
7100 | - | - | Supported | Supported | Supported | |
1750, 1720 | Supported | Supported | - | Supported | Supported | |
RSM (Catalyst 5000), RSM VIP (Catalyst 5000), 4700, 4500, 4000, 3600, 2600, 2500, 1600 | Supported | Supported | - | Supported | Supported | |
MSFC FlexWAN | - | - | Supported | Supported | Supported | |
Weighted fair queuing (WFQ) (or fair queuing (FQ) where indicated) | 7500, 7500 VIP (uses FQ only) | Supported | Supported | Supported | Supported | Supported |
7200 | Supported | Supported | Supported | Supported | Supported | |
7100 | - | - | Supported | Supported | Supported | |
1750, 1720 | Supported | Supported | - | Supported | Supported | |
RSM (Catalyst 5000), RSM VIP (Catalyst 5000; uses FQ), 4700, 4500, 4000, 3600, 2600, 2500, 1600 | Supported | Supported | - | Supported | Supported | |
MSFC FlexWAN | - | - | Supported | Supported | Supported | |
Distributed weighted fair queuing (DWFQ), fair queuing, and QoS group DWFQ | 7500 VIP | - | Supported | - | - | - |
7500, RSM VIP (Catalyst 5000), 7200, 7100, RSM (Catalyst 5000), 4700, 4500, 4000, 3600, 2600, 2500, 1600, MSFC FlexWAN | - | - | - | - | - | |
Class-based weighted fair queuing (CBWFQ) using Modular CLI (MQC) with policing | 7500, 7200, 4700, 4500, 4000, 3800, 3600, 2600, 2500 | - | - | Supported | - | Supported |
1750, 1720 | - | - | - | - | - | |
7500 VIP, RSM VIP, 7100 | - | - | Supported | - | Supported | |
Class-based weighted fair queuing (CBWFQ) using Modular CLI (MQC) with LLQ | 7500, 7200, 4700, 4500, 3600, 2600, 2500, 1600 | - | Supported | Supported | Supported | Supported |
1750, 1720 | - | Supported | Supported | Supported | Supported | |
Class-based weighted fair queuing (CBWFQ) using MQC with LLQ + set/match classification | 7500, 7200, 7100 | - | - | Supported | Supported | Supported |
4700, 4500, 3600, 2600, 2500, 1600 | - | - | - | Supported | Supported | |
1750, 1720 | - | - | - | Supported | Supported | |
7500 VIP, MSFC FlexWAN | - | - | Supported | - | Supported | |
RSM VIP | - | - | - | - | Supported | |
Class-based weighted fair queuing (CBWFQ) using MQC with RTP | 7500, 7500 VIP, 7200, 4500, 3600, 2600 | - | - | - | Supported | Supported |
7100, 4700, 4000, 2500, 1600 | - | - | - | - | - | |
1750,1720 | - | - | - | - | - | |
Class-based weighted fair queuing (CBWFQ) using MQC with FRTS | 7500, 7200, 7100, 4700, 4500, 3600, 2600, 2500, 1600 | - | - | - | Supported | Supported |
1750 | - | - | - | Supported | Supported | |
1720 | - | - | - | - | Supported | |
RSM VIP, 7500 VIP, MSFC FlexWAN | - | - | - | - | - | |
Class-based weighted fair queuing (CBWFQ) using MQC with GTS | 7500, 7200, 7100, 4700, 4500, 3600, 2600, 2500, 1600 | - | - | - | Supported | Supported |
RSM VIP, 7500 VIP, MSFC FlexWAN | - | - | - | - | - | |
1750, 1720 | - | - | - | - | Supported | |
Class-based weighted fair queuing (CBWFQ) using MQC with dTS and dFRF | 7500 VIP | - | - | Supported | - | Supported |
MSFC FlexWAN | - | - | Supported (no dFRF) | - | Supported (no dFRF) | |
7500 | - | Supported | Supported | Supported | Supported | |
7200 | - | Supported | Supported | Supported | Supported | |
7100 | - | - | Supported | Supported | Supported | |
4000 | - | Supported | Supported | Supported | Supported | |
1750 | - | - | - | Supported | Supported | |
1720 | - | - | - | - | Supported | |
4700, 4500, 3600, 2600, 2500 | - | Supported | - | Supported | Supported | |
1600 | - | Supported | - | - | - | |
RSM VIP, 7500 VIP, MSFC FlexWAN | - | - | - | - | - | |
Policy-based routing (PBR) (also called coloring or classification) | 7500, 7500 VIP, 7200, 7100, RSM (Catalyst 5000), RSM VIP (Catalyst 5000), 4700, 4500, 3600, 2600 | - | - | - | - | - |
4000 | Supported | Supported | - | Supported | Supported | |
2500, 1600 | Supported | Supported | - | - | - | |
7500 | Supported | Supported | Supported | Supported | Supported | |
7200 | Supported | Supported | Supported | Supported | Supported | |
7100 | - | - | Supported | Supported | Supported | |
1750, 1720 | Supported | Supported | - | Supported | Supported | |
RSM (Catalyst 5000), 4700, 4500, 4000, 3600, 2600, 2500, 1600 | Supported | Supported | - | Supported | Supported | |
7500 VIP, RSM VIP (Catalyst 5000) | - | - | - | - | - | |
MSFC FlexWAN | - | - | - | - | - | |
7500 | Supported | Supported | Supported | Supported | Supported | |
7200 | Supported | Supported | Supported | Supported | Supported | |
7100 | - | - | Supported | Supported | Supported | |
1750, 1720 | Supported | Supported | - | Supported | Supported | |
RSM (Catalyst 5000), 4700, 4500, 4000, 3600, 2600, 2500, 1600 | Supported | Supported | - | Supported | Supported | |
7500 VIP, RSM VIP (Catalyst 5000) | - | - | - | - | - | |
MSFC FlexWAN | - | - | - | - | - | |
Enhanced FRTS with Frame Relay fragmentation (FRF.12), Frame Relay fair queue, and Frame Relay voice configuration | 7200 | - | Supported | - | Supported | Supported |
3600, 2600 | - | Supported | - | Supported | Supported | |
7500, 7100, RSM VIP | - | - | - | - | Supported | |
1750, 1720 | - | - | - | - | Supported | |
Committed access rate (CAR) classification (also called coloring) | 7500, 7500 VIP, 7200 | Supported | Supported | Supported | Supported | Supported |
7100 | - | - | Supported | Supported | Supported | |
1750, 1720 | Supported | Supported | - | Supported | Supported | |
RSM (Catalyst 5000), RSM VIP (Catalyst 5000), 4700, 4500, 3600, 2600 | Supported | Supported | - | Supported | Supported | |
2500, 1600 | - | Supported | - | Supported | Supported | |
MSFC FlexWAN | - | - | Supported | Supported | Supported | |
4000 | - | - | - | - | - | |
7500, 7500 VIP, 7200 | Supported | Supported | Supported | Supported | Supported | |
7100 | - | - | - | - | Supported | |
RSM VIP (Catalyst 5000) | Supported | Supported | - | Supported | Supported | |
1750, 1720 | Supported | Supported | - | Supported | Supported | |
RSM (Catalyst 5000), 4700, 4500, 3600, 2600 | Supported | Supported | - | - | Supported | |
2500, 1600 | - | - | - | Supported | Supported | |
MSFC FlexWAN | - | - | Supported | Supported | Supported | |
4000 | - | - | - | - | - | |
Catalyst 8510, Catalyst 8540 | Supported | Supported | - | - | - | |
Catalyst 4003 with L3, Catalyst 4006 with L3, 4908GL-3, 2948GL-3 | Supported | Supported | - | - | - | |
7500 | Supported | Supported | Supported | Supported | Supported | |
7200 | Supported | Supported | Supported | Supported | Supported | |
7100 | - | - | Supported | Supported | Supported | |
4000 | Supported | Supported | Supported | Supported | Supported | |
7500 VIP, MSFC FlexWAN | - | - | Supported | Supported | - | |
4700, 4500, 3600, 2600, 2500 | Supported | Supported | - | Supported | Supported | |
1600 | Supported | Supported | - | - | - | |
RSM VIP | - | - | - | - | - | |
7200, 7100 | - | - | Supported | - | Supported | |
7500 VIP | - | - | - | - | - | |
2600, 3600 | - | - | - | - | Supported | |
7500, 7200, 7100, RSM (Catalyst 5000), 4700, 4500, 4000, 3600, 2600, 2500 | Supported | Supported | Supported | Supported | Supported | |
1600 | Supported | Supported | - | - | - | |
1750, 1720 | Supported | Supported | - | Supported | Supported | |
7500 VIP, RSM VIP, MSFC FlexWAN | - | - | - | - | - | |
7500, 7200, 7100, RSM (Catalyst 5000), 4700, 4500, 4000, 3600, 2600, 2500 | Supported | Supported | Supported | Supported | Supported | |
1600 | Supported | Supported | - | - | - | |
1750, 1720 | Supported | Supported | - | Supported | Supported | |
7500 VIP, RSM VIP, MSFC FlexWAN | - | - | - | - | - | |
All IOS devices, except 8500 | Supported | Supported | Supported | Supported | Supported |
1A Cisco IOS mapping function is used to enable QPM 2.0(x) to support 12.1(5)T and 12.1(2)E QoS techniques included in later releases of IOS main (T or E train) software. |
Cisco CATOS releases supported include 5.4, 5.5, and 6.1. In addition, a Cisco CATOS mapping function is used to enable QPM 2.0(x) to work with the supported QoS techniques of 5.4, 5.5, and 6.1 in later releases of CATOS.
The table below describes the QoS techniques that you can use with the devices and CATOS software releases that QPM supports.
Quality of Service Technique | Cisco Systems Device | Catalyst Software Release | ||
---|---|---|---|---|
5.4 | 5.5 | 6.1 and later1 | ||
Catalyst 5000 family with NFFC-II | Supported | Supported | Supported | |
Catalyst 6000 family with PFC | Supported | Supported | Supported | |
Catalyst 6000 family with PFC | Supported | Supported | Supported | |
Catalyst 6000 family with PFC | Supported | Supported | Supported |
1A Cisco CATOS mapping function is used to enable QPM 2.0(x) to work with the supported QoS techniques of 5.4, 5.5, and 6.1 in later releases of CATOS. |
The table below describes the QoS techniques that you can use with other devices and device software releases that QPM 2.0(x) supports.
Quality of Service Technique | Cisco Systems Device | Device Software Release |
---|---|---|
Packet classification (coloring) | LocalDirector | 3.1.1 |
For more information about QPM 2.0(x) and the CiscoWorks2000 product family, please see the following URLs:
http://www.cisco.com/warp/public/cc/pd/wr2k/qoppmn/
http://www.cisco.com/warp/public/cc/pd/wr2k
Posted: Tue Oct 1 14:22:36 PDT 2002
All contents are Copyright © 1992--2002 Cisco Systems, Inc. All rights reserved.
Important Notices and Privacy Statement.