cc/td/doc/product/rtrmgmt/cw2000/cw2000_b/cam_bun
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table of Contents

Read Me First—Campus Bundle for AIX, October Update

Read Me First—Campus Bundle for AIX, October Update

The Campus maintenance kit provides updates to applications.

Depending on which of the Campus Bundle applications you have previously installed, you can use different upgrade paths when installing the products in the bundle. If you are planning to install one of the Campus Bundle applications for the first time as part of this maintenance bundle, read the requirements for that component system carefully. If you are installing a previously uninstalled application, we recommend that you use the CD-ROM in this kit.

What the Bundle Contains

The Campus Bundle for AIX contains:


Note   In addition to the enclosed paper documents, PDF versions of product documentation are available on the product CDs. Refer to the installation instructions for individual products and print out the relevant documentation before proceeding with the installation.

Bundle Changes

This section highlights the major updates available for each of the components of the LMS maintenance kit. See the accompanying Release Notes for more detailed information.

The following applications are now all supported on AIX 4.3.3.

CiscoWorks2000 CD One Third Edition

CiscoView 5.2 provides increased performance and device support for the Catalyst 4908G-L3, Catalyst 4804G-L3, Catalyst 2948G-L3, Cisco VPN Concentrator, Cisco Metro 1500, Cisco 7000, Catalyst 6000, Catalyst 5500, Catalyst 5000, Catalyst 2900 series of devices with user security support for Cisco WAN Manager (release 10.4).

Resource Manager Essentials 3.2

Resource Manager Essentials 3.2 (Essentials) includes new VPN and Voice Management support. You can select VPN tasks from the desktop to provide configuration, inventory, and syslog analysis functions. Essentials also has added support for Cisco Call Managers, VPN Concentrator 3000 (VPN C3000), and PIX configuration and syslog analysis.

Campus Manager 3.0.1 Voice Update

The Campus Manager Voice Update allows you to discover or display Cisco CallManagers in Topology Services, track IP phones in User Tracking, and perform voice or data traces among Cisco CallManagers and IP phones.

The Voice Update also contains:

TrafficDirector 5.8.1a

TrafficDirector now supports the Catalyst 6000 Network Analysis Module and the Catalyst 6509.

Installation Prerequisites

Table 1 shows the minimum server requirements for each application and combinations of application.


Table 1: Minimum Server Requirements
Requirement Type CD One only CD One and Campus CD One and Essentials CD One and TD Entire LAN Bundle

Processor

RS6000 PowerPC

Model 604e

233 Mhz

RS6000 PowerPC

Model 604e

233 Mhz

RS6000 PowerPC

Model 604e

233 Mhz

RS6000 PowerPC

Model 604e

233 Mhz

RS6000 PowerPC

Model 150

375 Mhz

Memory (RAM)

256 MB

256 MB

256 MB

256 MB

512 MB

Swap space1

512 MB

512 MB

512 MB

512 MB

1 GB

Available drive space

2 GB

4 GB

4 GB and space for software management files

3 GB

6 GB and space for software management files

Additional Hardware

CD-ROM drive and 17-inch color monitor

System software

AIX 4.3.3 with patch xlc.rte 3.1.4.8, X11.Dt.lib 4.3.3.2, X11.Dt.rte 4.3.3.3, X11.adt.lib 4.3.3.0, X11.adt.motif 4.3.3.1, X11.base.lib 4.3.3.2, X11.base.rte 4.3.3.2, X11.compat.lib.X11R5 4.3.3.2, X11.motif.lib 4.3.3.2, X11.motif.mwm 4.3.3.1, bos.adt.include 4.3.3.1, bos.adt.prof 4.3.3.3, bos.net.tcp.client 4.3.3.3, bos.rte.libpthreads 4.3.3.3, bos.sysmgt.serv_aid 4.3.3.2, patch bos.mp 4.3.3.3 (multiprocessor only), patch bos.up 4.3.3.3 (uniprocessor only), or later

Browser

If used as a client, a browser is required (refer to Table 2)

1Swap space should be double the RAM. If your server has more than the minimum RAM, you must have more than the minimum swap space

Table 2 shows the minimum client requirements for a network with 950 devices or fewer.


Table 2: Minimum Client Requirements
Requirement Type Minimum Requirement

System Software and Hardware

  • Client system:

    • IBM workstation running AIX 4.3.3.

    • IBM PC-compatible computer with 300 MHz Pentium processor running Windows NT 4.0, Windows 95, or Windows 98.

    • Solaris SPARCstation or Sun Ultra 10 running Solaris 2.5.1 or Solaris 2.6.

    • HP-UX workstation running HP-UX 10.20 or 11.0.

  • Color monitor with video card set to at least 256 colors.

Memory (RAM)

256 MB

Browser

One of the following browsers:

  • Microsoft Internet Explorer 5.0 or 5.01(Windows NT, Windows 95/98).
    Java Virtual Machine (JVM) version 5.0.0.3186 or later.

  • Netscape Navigator 4.61 or 4.7

Installing the Bundle


Caution You must install CD One before installing any other applications. While it is strongly recommended that you follow the order of installation described in this section, you can install the applications in any order. However, you must have Campus Manager 3.0 already installed before you install Campus Manager Voice Patch.

Table 3 shows the recommended order in which you should install the software in this bundle.


Table 3: Order of Installation
Task For Detailed and Custom Installation, Refer To

    1. Install CiscoWorks2000 CD One Third Edition. This typically takes about 1 hour.

Installing and Setting Up CD One Third Edition on AIX.

Release Notes for CiscoWorks2000 CD One Third Edition on AIX for any last-minute updates to the installation instructions.

    2. Install Resource Manager Essentials 3.2 on the server. This typically takes about 1 hour.

Installing and Setting Up Resource Manager Essentials on AIX.

Release Notes for Resource Manager Essentials 3.2 on AIX for any last-minute updates to the installation instructions.

    3. Install Campus Manager 3.0.1 (Voice Update) on the server.1

Release Notes for Campus Manager 3.0.1 Voice Update on AIX.

    4. Install TrafficDirector 5.8.1 on the server. This typically takes about 15 minutes.

TrafficDirector Release 5.8.1a Installation Guide for HP-UX and AIX.

Release Notes for TrafficDirector Release 5.8.1a on HP-UX and AIX for any last-minute updates to the installation instructions.

1Installing Campus Manager 3.0.1 (Voice Update) is optional. Refer to the release notes for more information about the Voice Update and for installation instructions.

Getting Started

You must complete the following tasks before starting up LMS.


Table 4: Getting Started
Task Refer To

    1. Set up the CiscoWorks2000 Server

Getting Started with the CiscoWorks2000 Server

    2. Prepare to use CD One

Installing and Setting Up CD One Third Edition on AIX

    3. Prepare to use Resource Manager Essentials applications

Installing and Setting Up Resource Manager Essentials on AIX

    4. Prepare to use Campus Manager applications.

Installing and Setting Up Campus Manager on AIX

    5. Prepare to use TrafficDirector

TrafficDirector Release 5.8.1a Installation Guide for HP-UX and AIX

Related Documentation

The following paper documentation ships with LMS:

The following related documentation is also available as PDF files on the product CD-ROMs and on CCO:


Note   Adobe Acrobat Reader 4.0 is required to view PDF files.

Online help is available from within the products.

Ordering Additional Documentation

A complete set of hardcopy user guides for the products contained in the Campus Bundle can be ordered using the part number CWDOC-RWAN-LMS.

Orders for documentation can be placed through an authorized Cisco reseller or a Cisco sales representative.

Individual installation and user guides can be purchased using the Cisco MarketPlace ordering system. Cisco sales representatives, resellers, and users with direct ordering privileges can locate documentation part numbers and other ordering information by selecting the Documentation product family within MarketPlace and navigating to the CiscoWorks2000 section.


hometocprevnextglossaryfeedbacksearchhelp
Posted: Tue Dec 26 03:19:10 PST 2000
Copyright 1989-2000©Cisco Systems Inc.