December 17, 1997
This document discusses the CiscoView 4.1(1) release and contains the following information:
| Caution Before installing CiscoView or CiscoView devices, read the caveats in "Installation Notes and Caveats" on page 11 to understand any issues that might affect your platform. |
Table 1 shows supported CiscoView devices by product type.
Small to Medium Business Products | Mid-Range Enterprise Products1 | High-End Enterprise Products |
---|---|---|
Cisco and CiscoPro 761, 762, 765, 766, 771, 772, 775, 776 | Catalyst and CiscoPro switch models2 1200, 1400, 1600, 1601, 1700, 1800, 1900, 2100, 2600, 2800, 2820, 2900, 2926, 3000, 3100, 3200, 3900, 5002, and CPW2200 | Catalyst 5000, 5500, and 5505
|
Cisco or CiscoPro 1003, 1004, and 1005 | EtherSwitch Pro16,EPS2015, 1200, 1220, 1400, 1420 | Cisco 7000, 7010, 7204, 7206, 7505, 7507, 7513 routers |
Cisco and CiscoPro 1601, 1602, 1603, 1604, 1605 | EtherSwitches: Pro16 and CPW16 | LS10103
|
Cisco 2501, 2502, 2503, 2504, 2505, 2507, 2509, 2510, 2511, 2512, 2513, 2514, 2515, 2516, 2520, 2521, 2522, 2523, 2524, and 2525 | CiscoPro switch models CPW10_100, CPW500, CPW1200, CPW1220, and CPW1400 |
|
CiscoPro 2051, 2052, 2503, 2504, 2505, 2507, 2509, 2511, 2513, 2514, 2516, 2520, 2521, 2522, 2523, and 2524 | Workgroup concentrators 1400 |
|
Cisco and CiscoPro 3600 series (includes 3620 and 3640) | Fasthub 216T |
|
Cisco and CiscoPro 4000 series4 (includes 4000, 4000-M, 4500, 4500-M, 4700, and 4700-M) |
|
|
AS5200 Access Server | AS2509-RJ | AS5300 Access Server |
Cisco 1501, 1502, 1503, 1516 |
|
|
NetBeyond Fasthub 300 and Fasthub 100+ Series |
|
|
EPS-500, EPS-1500, EPS2115, CPW-500, CPW-2115, and CPW-16 |
|
|
Other supported CiscoView applications are shown in Table 2.
Application | Description | OS | Cisco IOS | Device Support |
---|---|---|---|---|
Threshold Manager | Monitors the availability and performance of Cisco devices | Solaris 2.4, with recommended patches as of 3/16/95, Solaris 2.5.1, and 2.6 | Cisco IOS 11.1 or 11.2 with RMON events and alarms group support | All devices with appropriate Cisco IOS or RMON features
|
StackMaker | Manages the device membership in a Cisco stack | Solaris 2.4, 2.5.1, and 2.6 | Cisco IOS 10.0 through 11.2 | Cisco and CiscoPro 1600, 3600, 3620, 3640, Catalyst 1900, Catalyst 2820, CPW1220, CPW1420, Fasthub 100+ and Fasthub 300 |
Flash File System | Provides file copying and editing features for the 7000 Series routers | Solaris 2.4, 2.5.1, and 2.6 | Cisco IOS 10.0 through 11.2 | Cisco 7000, 7010, 7204, 7206, 7505, 7507, 7513 routers |
Cisco TN3270 Monitor | Monitor/configures TN3270 capability embedded in Cisco devices with IBU feature set. | Solaris 2.4, 2.5.1, and 2.6 | Cisco IOS 11.0(13)BT or 11.2 with cip22-14 | Cisco 7000 and 7500 (with a CIP card) |
The CiscoView devices packages included in this release are shown in Table 3.
Device Package | Version |
---|---|
1000.pkg | 4.0(1.2) |
1500.pkg | 4.0(1.2) |
1600.pkg | 4.0(4.2) |
2500.pkg | 4.0(3.1) |
3600.pkg | 4.0(6.1) |
4000.pkg | 4.0(2.4) |
700.pkg | 4.0(1.4) |
7000.pkg | 4.0(3.0) |
AS5200.pkg | 4.0(3.1) |
AS5300.pkg | 4.0(1.1) |
CPW10_100.pkg | 4.0(1.4) |
CPW1200.pkg | 4.0(1.4) |
CPW1220.pkg | 4.0(1.5) |
CPW1400.pkg | 4.0(1.4) |
CPW1420.pkg | 4.0(1.5) |
CPW16.pkg | 4.0(1.1) |
CPW2115.pkg | 4.0(1.1) |
CPW2200.pkg | 4.0(1.5) |
CPW316.pkg | 4.0(1.4) |
CPW500.pkg | 4.0(1.1) |
Cat116.pkg | 4.0(1.4) |
Cat1200.pkg | 4.0(1.4) |
Cat1600.pkg | 4.0(1.2) |
Cat1700.pkg | 4.0(1.4) |
Cat1800.pkg | 4.0(1.1) |
Cat1900.pkg | 4.0(1.6) |
Cat2100.pkg | 4.0(1.4) |
Cat216.pkg | 4.0(1.1) |
Cat2600.pkg | 4.0(1.2) |
Cat2800.pkg | 4.0(1.4) |
Cat2820.pkg | 4.0(1.5) |
Cat2900.pkg | 4.0(1.7) |
Cat3000.pkg | 4.0(1.6) |
Cat3900.pkg | 4.0(1.1) |
Cat5000.pkg | 4.0(1.8) |
Cat5500.pkg | 4.0(1.7) |
Cisco1516.pkg | 4.0(1.1) |
EPS2015.pkg | 4.0(1.1) |
LS1010.pkg1 | 4.0(1.4) |
1Please upgrade to LS1010 device package version 4.0(1.8). This package can be downloaded from CCO. |
This section contains the latest Cisco IOS (Internetwork Operating System) software version information at the time of printing.
CiscoView supports Cisco IOS software Releases 10.0 through 11.2. Access servers require a minimum of Cisco IOS software Release 10.2. Cisco 3600 devices require Cisco IOS software Release 11.1 or later. Cisco 4000 series devices require Cisco IOS software Release 10.3 or later.
New devices and further specifics on Cisco IOS support will be updated as devices become supported. For the online release notes, refer to one of the following:
The documentation for CiscoView includes this release note, a CD-ROM booklet, an overview manual, and online help. The primary documentation for CiscoView is the online help. If you have documentation feedback, please email comments to
bug-doc@cisco.com
The documents shipped with this release include:
Customer documentation can also be found on the Cisco Enterprise Customer Documentation CD or on CCO.
There are several ways to add (or incrementally install) new devices to CiscoView 4.1. For our direct customers, refer to the section "Cisco Connection Online." For our partner-initiated customers, refer to the section "Partner Initiated Customer Accounts."
You can add new devices to CiscoView from CCO or from the Network Management Support CD. For more information, refer to the "Downloading Device Packages" chapter in Overview for CiscoView. A quick reference version exists in the CiscoView CD Installation Instructions booklet.
For Solaris:
The pkgadd command is no longer used for installation. Please use setup.sh. See the CiscoView CD Installation Instructions booklet for the most up-to-date version of install.
To get more information about the Partner Initiated Customer Accounts (PICA) program before accessing CCO for device package files, use the following URL:
http://www.cisco.com/acs/info/pica.html
You can also refer to the "Downloading Device Packages" chapter in Overview for CiscoView.
The following problems in CiscoView 4.0(1) are fixed in CiscoView 4.1(1). Table 4 lists only the most serious problems resolved in CiscoView 4.1(1).
CSCdj03079 | Upgrade from cv311 to cv40 fails |
CSCdj07135 | 10BaseT interface fails to Select |
CSCdj07195 | CiscoView install does not clean up before exit if disk full |
CSCdj07710 | Unable to configure cat 5000 port |
CSCdj09056 | CiscoWorks tools missing in CiscoView |
CSCdj12055 | CiscoView installation removes some of the symbols supported by CW 3.0 |
CSCdj12074 | CiscoView deinstallation does not remove menu entry from NetView |
CSCdj12860 | SanFran:Etna module reports error messages while getting displayed |
CSCdj14942 | CiscoView: 5111 and 5011 cards don't have link ports |
CSCdj15629 | CiscoView engine crashed due to continuously polling large table |
CSCdj15790 | 7000 symbol registered for 7010 router in oid_to_sym |
CSCdj17659 | Cannot set Token Ring segment -cat1600 |
CSCdj18660 | LS1010:LEDs on IBIS PAM not labeled |
CSCdj26323 | Fractional interfaces are displayed for one port only |
CSCdj28590 | ATM interface stats to be computed based on frames, not octets |
CSCdj30092 | HP-UX: Cannot modify VLAN Number in port config for Catalyst 5000 |
CSCdj30370 | Errors during configuration - ERROR: failed to create /C/CiscoS |
CSCdj35453 | CW + CWSI 1.3 + CV 4.0 = Failure |
CSCdj38584 | Cannot configure due to missing fonts |
CSCdj41569 | CiscoView does not have a feature to deinstall a package |
CSCdj57471 | Warnings while invoking OVW (Duplicate definitions of Cisco Router) |
If you cannot open a device in CiscoView 4.1, a message appears indicating that the device is unmanageable for one of the following reasons:
This section contains notes and restrictions that apply to the CiscoView 4.1 release.
Installation notes and caveats for CiscoView follow:
After upgrading CiscoView 3.2.1 to 4.1, some links may remain in the $SUNHOME/snm/agents directory, where SUNHOME is Solaris SunNet Manager home directory (normally, /opt/SUNWconn). [CSCdj13160]
You can remove the links that point to invalid files by running the following script:
#!/bin/sh
SUNHOME=/opt/SUNWconn
cd $SUNHOME/snm/agents
ls | while file=\Qline\Q
do
FILE=\Qls -ld $file | awk '{ print $NF }'\Q
if [ ! -f "$FILE" ]; then
rm "$FILE"
fi
done
When a device package is installed, CiscoView updates HP OpenView with the device symbols and bitmaps. If the CiscoView devices are shown as default Network Devices icons in HP OpenView Windows, perform the following:
#!/bin/sh
/opt/OV/bin/ovstart
/opt/OV/bin/ovstop netmon
cp /etc/opt/OV/share/conf/C/oid_to_sym /etc/opt/OV/share/conf
rm /etc/opt/OV/share/conf/C/oid_to_sym
ln -s /etc/opt/OV/share/conf/oid_to_sym /etc/opt/OV/share/conf/C/oid_to_sym
/opt/OV/bin/ovtopofix -a
/opt/OV/bin/ovstart netmon
Before integrating CiscoView 4.1 with Enterprise Manager 2.0, apply EM patch 104170-04 to the Enterprise Manager installation. Without this patch, the Enterprise Manager Discover utility will not discover Cisco devices. [CSCdj63240]
If CiscoView fails to come up because of missing fonts, you can choose a font by editing the cview.ini file, which is in the $NMSROOT/etc/cview directory. [CSCdj57455]
Warnings and error messages that are generated when you incrementally install device packages are logged into the log file devinstall.log in the CiscoView base directory (/opt/CSCOcv or /usr/nms/CVapp). You can use the log file for troubleshooting if a device package installation fails. The file can be cleaned up after a successful device package installation. [CSCdj47801]
If you are upgrading CiscoView 4.0(1) to CiscoView 4.1(1) and /usr/nms or /usr/nms/CVapp is a symbolic link, the link is removed by SMIT (installp utility). To overcome this, remove the link, mount the actual directory to /usr/nms/CVapp, and perform the upgrade. You can also remove the previous version of CiscoView and perform a fresh installation. [CSCdj41509]
CiscoView does not remove symbols, bitmaps, fields, and MIBs from HP OpenView/AIX NetView directories during deinstallation.
Deinstallation leaves the file ciscoview.schema in the $SUNHOME/snm/struct directory. You should remove this file after deinstalling CiscoView 4.1. [CSCdj62915]
If CiscoView does not appear in the Tools menu in Solstice Site Manager/Domain Manager, perform the following steps:
Step 1 Copy the file ciscoview.schema from the $NMSROOT/etc/cview/snm/struct directory to $SNMHOME/snm/struct, where NMSROOT is the CiscoView home directory (typically /opt/CSCOcv).
Step 2 Edit the $SNMHOME/snm/struct/ciscoview.schema file and replace the string "$NMSROOT" with your CiscoView home directory.
When CiscoView 4.1 is installed with CiscoWorks for Switched Internetworks (CWSI) 1.1, you are unable to read VlanDirector help. This error occurs when you select Help>VLAN or Help>Contents. The workaround is to log in as root and enter the following at the command prompt:
# cp /cdrom/install/.config/vlanview.hlp /opt/CSCOcv/help
CiscoView 4.1(1) does not support an upgrade from CWSI 1.1. To upgrade CWSI to CiscoView 4.1(1), first upgrade CWSI 1.1 to CWSI 1.3 (or higher) and then upgrade to CiscoView 4.1(1).
CiscoView 4.1(1) is not compatible with CiscoWorks 2.x. There are two solutions. You can upgrade to CiscoWorks 3.2.1 or later or remove it.
Even when one package is being installed incrementally, CiscoView updates HP OpenView/AIX NetView with symbols, bitmaps, and fields from all installed device packages. [CSCdj41573]
Some errors will be reported during the installation or incremental installation of device packages when MIBs are loaded into AIX NetView. For more information and workaround suggestions, refer to the following URLs:
http://www.cisco.com/public/mibs/app_notes/mib-compilers
or
ftp://ftp.cisco.com/pub/mibs/app_notes/mib-compilers
Update the path variable to include the path for the snm binaries and also set the SNMHOME environment variable.
C Shell:
setenv SNMHOME /opt/SUNWconn/snm
set path=($path /opt/SUNWconn/snm/bin)
Bourne Shell:
SNMHOME=/opt/SUNWconn/snm
export SNMHOME
PATH=$PATH:/opt/SUNWconn/snm/bin
export PATH
The /opt/SUNWconn/snm directory is the default directory for SNM in Solaris. If SNM is installed elsewhere, please change the SNMHOME and path variables accordingly.
The SNM Discover utility will not work if all the device packages are installed for CiscoView 4.1. This bug requires SNM patches for SNM 2.3. You can download the patches can be downloaded from Sun Microsystem's official patch site [CSCdj01623]:
ftp://zippy.telcom.arizona.edu/pub/snm/patches/Solaris2.x/SNM2.3/104018-02.tar.Z
The CiscoView installation on Solaris might fail if you do not install a Hewlett-Packard patch. This patch is required to install NNM 4.1 on Solaris 2.5.1 and must be installed before installing NNM 4.1. This patch is required to run a license server on Solaris 2.5.1. If your license server is on a different machine, this patch is not necessary.
Both patches consist of a tar file and a text file describing the patch. To obtain a patch
Step 1 Enter the following URL:
ftp://ovweb.external.hp.com/pub/cpe/patches/nnm/4.1x
Step 2 Click on the appropriate links to get to your software patch.
Patch numbers are not available because HP consolidates the patches periodically to contain all previous fixes. Select the one related to Network Node Manager 4.1x by viewing the patch text files. If you have difficulty installing the patch, contact HP Service and Support.
The CiscoView installation uses the Solaris pkgadd utility. When pkgadd finishes installing CiscoView, the screen shows that the installation was successful but does not quit. Type Q to exit the pkgadd utility.
The general notes and caveats follow. They are divided into six sections:
For some devices, config/monitor does not work for multiple ports. [CSCdj65066]
CiscoView does not support internationalization.
In high traffic situations, you might experience timeouts. To increase the timeout period, select Options>Properties from the CiscoView menu and change the value for the Timeout field.
You should not reduce the physical view polling interval below (retries*timeout), especially if you experience timeouts; this can exhaust resources on Windows and result in a general error.
For this release, use the middle mouse button to drag on UNIX. Only certain devices (such as the CAT1200, CAT1600, CAT5000, CPW16) have defined their ports for dragging across devices.
If a switch is configured as two or more domains, HP OpenView discovery might not work properly and might discover only one of the domains. If this occurs, use CiscoView to manage the domain directly rather than launching the switch from the map.
By default, SNMP standard traps are logged in the trapd.log file in HP OpenView 4.1. To view the standard traps in the event window, use the Option>Event Configuration menu to change the standard trap configuration. [CSCdi91796]
Traps defined in the MIB BRIDGE-MIB.my are not loaded into HP OpenView. Because of this, HP OpenView does not recognize the traps newRoot and topologyChange. [CSCdj62552]
Sometimes, because of font scaling problems, HP OpenView grapher cannot be invoked. Refer to the description provided in the following app-defaults file for HP OpenView grapher applications for more information.
/opt/OV/newconfig/OVNNM-RUN/app-defaults/C/XNm*
While some devices are being invoked, a number of MIB variables are queried and the NetView grapher is invoked. Some of the queries might time out often (three or more occurrences). If this happens, CiscoView does not exit gracefully and produces a core dump. [CSCdj04380]
When you select Monitor>Port and invoke the Grapher, the Grapher does not display the data. Currently working with Sun Microsystems to resolve this problem.[CSCdj01623]
When you use CiscoView 4.1 with Enterprise Manager 2.0, sometimes the em_discover application terminates abnormally. [CSCdj56566]
Popup menu titles are raised; users might mistake them for menu items. [CSCdi53475]
CiscoView might fail to print to a LaserJet III printer, especially in the "LaserJet" format, because of this printer's limited memory.
If the server or display workstation is running out of swap space, you see a message such as "X error: Couldn't allocate color cell," and CiscoView core dumps. If you are running other applications, you should check your swap space occasionally.
To check swap space on a Sun Solaris 2.x workstation, enter the following:
hostname% swap -l
If your system is running out of swap space (for example, only 200 KB of swap space remains), quit some of the other applications you are running or increase your swap space, if possible. [CSCdi37063]
Internal DebuggingWhen the StackMaker Debug option is set to On, debug messages print to the StackMaker Debug Log file. The default is Off. The StackMaker Debug Log file stores messages that are useful in troubleshooting problems. This log file is /tmp/.smDebugLog.
Internal DebuggingWhen the StackMaker Debug SNMP option is set to On, SNMP debug messages print to the StackMaker Debug Log file on the UNIX platform. The messages show the SNMP packets that have been sent and received. The default is Off. The StackMaker Debug Log file stores messages that are useful in troubleshooting problems. This log file is /tmp/.smDebugLog.
Log File from Apply OperationsThe StackMaker log file stores the results of a saved stack configuration (Actions>Apply Stack Configuration). The log file is /tmp/stackmkr/sm.log. When the log file exceeds 1 MB, it automatically resets to 0 bytes.
When StackMaker is invoked on Catalyst 1900 devices, some debug output is printed to the console. You can ignore this output.
Some agents, most notably the Catalyst switches, impose a limit on the number of alarm and event entries that can be created. Applying a large number of thresholds to these devices will likely fail. In this case, some alarm entries might be successfully created but their associated event entries are not. These failed creations are marked as Failed in the Current Threshold Settings pane. If you attempt to delete those settings, Threshold Manager reports that the deletion failed (because it cannot delete nonexistent event entries.) In this case, you can ignore the error message and can verify that the deletion occurred by retrieving the threshold settings after the deletion.
New policies are always added to the display list.To view the new policies, exit the Configure Thresholds window, then reopen it. [CSCdi62741]
Policy filenames do not match if the IP address is used. To correct this, use the host name instead of the IP address when saving host-specific policies. [CSCdi62739]
Duplicate global/device/host policies may be allowed, depending on which window is used. When creating a custom policy, you can save it only once, either as global, device, or host. But after saving the policy, you can use the Modify Threshold Policy window to modify the saved custom policy and save it as all three. [CSCdi68329]
When you use the Switch Zoom menu (if TrafficDirector is installed) from CiscoView to view multiple switch ports, the default configuration for the Catalyst 1200 is Statistics, Short-Term history, Long-Term history, and Host group. To see the Short-Term or Long-Term history from Traffic Monitor, use the Domain Manager to configure the Short-Term and Long-Term groups manually or use Segment Zoom to view the port first.
When using the Segment Zoom menu from CiscoView to view the port segment, the default configuration for the Catalyst 1200 is the Statistics, Short-Term history, Long-Term history and Host group. For the Catalyst 5000 it is Statistics, Short-Term history, and Long-Term history.
If you get the "Error: Entry or Group not present in Agent" message when invoking Segment Zoom, Switch Zoom, or Data Capture, the write community string might not be matched with the device. If the community string is matched and the problem still occurs, use the CiscoView Configure Device menu to see whether the RMON capability is enabled.
If you launch Switch/Port Zoom from CiscoView and then delete one of the RMON Agents using TrafficDirector, you must relaunch CiscoView before launching Switch/Port Zoom again.
If you see "IP address is not set in sysIpAddr Mib variable," it is because the Catalyst 1200 SNMP agent does not store the correct IP address in the sysIpAddr MIB variable. You must use CiscoView to correct it. Select Configure>Device, enter the correct IP address in the corresponding field, and click Modify.
TrafficDirector 3.3 cannot be launched for interfaces with ifIndex values greater than 1000.
The device agent does not update the IP address table of MIB-II properly and does not reflect the correct IP address information of all the device interfaces. You cannot view the correct IP address information of the device by selecting Device>Configure>IP Address Table.
You cannot create new static entries for IP Route Table and ARP Table through CiscoView.
In the interface configuration (Port>Config>Interface), modifying the IP parameters always displays an error message, but the modification is successful.
You cannot change the bridge type of the FDDI port to sr-only or srt.
You cannot change the bridge type of the Token Ring port to srtb or tb-only.
The system time configuration is not included as part of device configuration.
CPW1200, CPW1220, CPW1400, CPW1420, Catalyst 1900, Catalyst 2100, Catalyst 2800, and Catalyst 2820The General Bridge window shows the bridge information for VLAN1 only. Bridge information for other VLANs is not available.
CPW1220, CPW1420, Catalyst 1900, and Catalyst 2820In the CDP Configuration Dialog, changing the transmission time of one port changes the transmission time of all ports. This is a feature of the implementation of the corresponding MIB objects in the device firmware. [CSCdi83959]
CPW1200, CPW1220, CPW1400, CPW1420, Catalyst 1900, Catalyst 2100, Catalyst 2800, and Catalyst 2820The Spanning Tree Protocol Window for switched ports is available for ports in VLAN1 only. This window does not show valid information for ports not in VLAN1.
If CiscoView for Cat1900 is invoked, the following message is displayed on the console. You can ignore the message. [CSCdj62767]
Sess0 21 noSuchName 1 {{1.3.6.1.4.1.437.1.1.3.2.19.0 noSuchObject N/A}}
On the front panel display of the device, the Connect and Disabled LEDs on FDDI modules do not reflect the appropriate status.
Although a Monitor menu option is available for both FDDI and repeater ports, this feature is not supported on these modules. [CSCdj57452]
The Configure>Module option is supported only for one module type, even though it can be invoked for multiple module types.
There is a dependency between the CPW1420 and Cat2820. The CPW1420 device package will not run unless the Cat2820 package is installed. [CSCdj64496].
The Catalyst 2600 device package contains two versions of the enterprise MIBs for the Catalyst 2600 switch:
If you are using a MIB browser tool, you will see the MIB variables defined in each of the above files, under different branches, at the same time, although any particular Catalyst 2600 switch will respond to queries on only one of the MIBs, based upon the release of software in the device. Cisco recommends that you upgrade your Catalyst 2600 switches to version 2.2.1 or later.
Under a heavy load condition, SNMP responses are slow. You might see an "error, no response since...." message in the CiscoView status window. Select Options>Properties and increase the Polling Frequency and Timeout values. [CSCdi57962]
If the number of the embedded RMON agent is over 50, you cannot create any new embedded RMON agent group for the new port. Use the Domain Manager to uninstall the agent group from the unused port to free the memory resource.
If you launch Switch/Port Zoom (if TrafficDirector is installed) from CiscoView and then delete one of the RMON Agents using TrafficDirector, you must relaunch CiscoView before launching Switch/Port Zoom again.
TrafficDirector 3.3 cannot be launched for interfaces with ifIndex values greater than 1000.
When multiple ports are selected, the Port>Configure window does not display the Broadcast Suppression category. This category is available only for single port selection.
When you enable port security administration on a port, there may be timeouts. If this happens, increase the SNMP timeout value to approximately 10 seconds.
The WS-X2901 module shows the speed LED lit only when the speed is configured as 100 Mbps and the port is connected.
The Port Utilization tool has been removed from the Tools menu and is now available only on a per module basis on the Config>Module menu.
When you reinstall or perform a cvinstall -f of CiscoView 4.1 and integrate with HP OpenView 4.11, you will see an error relating to the C3_2_0.my MIB file display. This error is because of duplicate definitions in the Catalyst 3000 MIB files. To correct this problem, download a new copy of the Catalyst 3000 package from the CCO web site. This package resolves CSCdj03981.
When you access a stack with six or more devices, there might be some significant performance problems. You can improve performance by increasing the SNMP timeout settings.
The Catalyst 3000 software does not support RMON on either a stack or an ATM port.
You might notice timeout messages and SNMP Set Failed messages when using the EtherChannel Configuration tool. If this happens, increase the SNMP timeout values for better performance.
If you are running version 2.0(1) of the Catalyst 3000 software, you will not be able to drag a port to a VLAN that does not already have ports assigned to it. You can fix this problem by upgrading to a later release of Catalyst 3000 software.
If you are running version 2.0(1) of the Catalyst 3000 software, changes to Full/Half Duplex settings will not always be reported correctly. You can fix this problem by upgrading to a later release of Catalyst 3000 software.
If you are running version 2.0(1) of the Catalyst 3000 software, the SAID value entered when creating a new VLAN will be redisplayed as a different value. However, the VLAN will have been created with the SAID value you specified. You can fix this problem by upgrading to a later release of Catalyst 3000 software.
The Domain Configuration and EtherChannel Configuration tools are not supported on Windows 95.
Because of restrictions in the Catalyst 3000 software, the WS-X3006B is displayed in CiscoView as a WS-X3006A.
If you launch Switch/Port Zoom (if TrafficDirector is installed) from CiscoView and then delete one of the RMON Agents using TrafficDirector, you must relaunch CiscoView before attempting to launch Switch/Port Zoom again.
CiscoView does not show the rear view of the Catalyst 3900 box.
When you attempt to drag port(s) to drop into one of the CRFs in the VLAN table, CiscoView might exit with an error. To work around this problem, first select the ports of interest, then bring the focus back to the VLAN Table window, and then drag the selected port(s) and drop them into the desired CRF.
The Configure... option under the Bridge Configuration category allows you to view a current configuration only. It reports an error when you attempt to configure new values for any parameter.
The Threshold Manager and TrafficDirector applications have not been fully tested with the Catalyst 3900.
While integrating some device packages with HP OpenView for HP-UX/Solaris or AIX NetView, some Catalyst 5000 device-specific traps are not integrated into HP OpenView. [CSCdj63184]
After an online insertion/removal (OIR) event (also called a "hot-swap"), CiscoView does not show the correct module or port status. The only way to display the correct status is to reopen the device or relaunch CiscoView. [CSCdj39860]
ATM, FDDI, and CDDI do not support Broadcast Suppression.
In machines that do not have a /tftpboot directory (such as a PC), an error is displayed whenever the Upload/Download feature is invoked on a Catalyst 5000 module.
Do not use the Grapher in the CiscoView Monitor 10BaseT Group Switching Ethernet window. Use the Monitor or TrafficDirector tools (if TrafficDirector is installed) to see graphical views of the selected repeater ports.
When you use the Switch Zoom menu (if TrafficDirector is installed) from CiscoView to view multiple switch ports, the default configuration for the Catalyst 5000 is to configure Statistics only. To see the Short-Term or Long-Term history from Traffic Monitor, use the Domain Manager to configure the Short-Term and Long-Term groups manually or use Segment Zoom to view the port first.
When you use the Segment Zoom menu from CiscoView to view the port segment, the default configuration for the Catalyst 5000 is Statistics, Short-Term history, and Long-Term history.
If you see the message "Error: Entry or Group not present in Agent" when invoking Segment Zoom, Switch Zoom, or Data Capture, the write community string may not be matched with the device. If the community string is matched and the problem still occurs, use the CiscoView Configure Device menu to see whether the RMON capability is enabled.
When you select the repeater module port on a Catalyst 5000, it always uses the first port of the selected segment to create the RMON agent group.
If all Catalyst 5500 slots are populated with modules and you experience timeouts, increase the SNMP timeout value to 15 seconds.
The WS-X5213 and WS-X5213A modules show the 100 Mbps speed LED lit only if the speed is configured at 100 Mbps and the port is connected.
Opening the FDDI/Ethernet Bridge category under Configure>Device can display an "unknown error." This is because of a problem with the device software.
If a general error (genErr) is displayed when you change vlanPortIslStatus, the selected port might not support ISL.
The values of ifAdminStatus and ifLinkUpDownEnable cannot be changed on an ATM port.
Port duplex settings cannot be changed on ATM and FDDI ports.
The value portSpanTreeFastStart cannot be changed on ATM and FDDI ports.
Configuring ports to unsupported speeds returns a general error (genErr). This is because of a problem in the device software.
The following list details the availability of Broadcast Suppression in terms of pps (packets per second) or % (percentage) for modules on Catalyst 5000 series switches. A plus sign (+) means available, while a minus sign (-) means not. Modules not on this list do not have Broadcast Suppression. The Broadcast Suppression feature is not available on ATM and FDDI. [CSCdi90909]
Module | Packets per Second (pps) | Percentage | Note |
---|---|---|---|
|
|
|
|
WS-X5013 | + | + |
|
WS-X5011 | + | - |
|
| | | % available with newer hardware only |
WS-X5113 | + | - |
|
WS-X5111 | + | - |
|
WS-X5213 | + | - |
|
WS-X5020 | + | - |
|
WS-X5114 | + | - |
|
WS-X5223 | + | + |
|
WS-X5224 | + | + |
|
WS-X5213A | + | - |
|
For devices that have an expansion module, the port numbering is not consistent with the management console. Ports 17 through 32 are listed in CiscoView as Repeater 2: Port 1 through 16. [CSCdi77159]
After the first reset of the device, the user must set the rptrReset MIB variable to noReset (default value) before the next reset can be performed. This is because of a problem on the device software and will be fixed in a later release. [CSCdi77452]
The CPW 1200/1400 and Cat 2100/2800 devices do not support the CDP and CGMP protocols. The CiscoView dialogs for these will return errors.
When the user enters values for the read-only, write-only, and read-writeId with the Command Line Interface (CLI) commands, these values must match. A mismatch results in noSuchName or timeout errors. To avoid these error conditions, use identical community strings in CiscoView and corresponding agents.
When multiple ports of different types are selected, Port>Config may show duplicate categories.
The following firmware versions must be used in the switches:
If you configure EtherChannel or Virtual Domains in Kalpana switch models EPS2015RS, EPS2115RSM, and Pro16 while running version 9.0 firmware with STP active, the map icons become red, and you receive the following error message:
No response from the device
After restarting the system, deactivate STP before you reconfigure. This problem is fixed in version 9.1 of the device firmware. [CSCdi41317]
When launching TrafficDirector 4.1.3 from CiscoView make sure that /usr/lib is included at the start of the LD_LIBRARY_PATH environment variable. A segmentation fault may occur if it is not included.
If you launch Switch/Port Zoom from CiscoView and then delete one of the RMON Agents using TrafficDirector, you must relaunch CiscoView before attempting to launch Switch/Port Zoom again.
TrafficDirector 3.3 cannot be launched for interfaces with ifIndex values greater than 1000.
The following network processor modules are supported:
The following network processor modules are supported:
A Cisco IOS defect causes CiscoView to not display the DS1 Line Channelized info when a T1/E1 port is configured for cas-group. This is applicable when the option is selected from the global menu item Connection Info or if it is selected through the Line_ds1 config dialog box. [CSCdj44707]
In the channel_modem view, CiscoView does not properly reflect the status of the T1/E1 channel_ports (timeslots) that have been configured for channel-group. This is a Cisco IOS software problem.
The following WAN interface cards are supported:
The following WAN interface cards are supported:
The following network modules are supporrted:
For the BRI interface in 8-port BRI cards or 4-port BRI card, the configure and monitor information shown in CiscoView is not correct. The information does not correspond to the correct BRI interface. This problem is present only if you use Cisco IOS Release 11.2 and above. This is a Cisco IOS software defect, CSCdj50307.
The hot swap feature is not available for stacked Cisco 3600 series routers.
Whenever the async/sync port configuration is changed, you must reopen the stack for CiscoView to update the async/sync port status. However, the hot swap feature for the async/sync ports is supported for individual Cisco 3600 series routers.
Also, whenever the async/sync port configuration is changed in a 16/32 port asynchronous network module, you must reopen the stack to obtain the latest state. However, the hot swap feature for the async/sync ports is supported for individual Cisco 3600 series routers.
The Logical view and Channel Modem Mapping view are not available for stacked Cisco 3600 series routers. This support is scheduled for a future release. However, for individual Cisco 3600 routers, Logical View is available if a digital modem carrier card is present, and Channel Modem View is available if a CT1/CE1 card is present.
The fix for defect CSCdi69480 (PRI/E1 interfaces missing in cardIfIndex table) is integrated into Cisco IOS Release 011.001(007) and above. The Cisco 3600 4.0(6.1) device package incorporates the fix and may not work properly with Cisco 3600 series routers running Cisco IOS versions below 011.001(007).
The following network processor modules (npm) are supported:
For 4000 series routers running Cisco IOS Release 10.2 or earlier, the displayed status color is determined from the port's administrative status (ifAdminStatus) and operational status (ifOperStatus) values. This status color will be the same on each connector. For devices running Cisco IOS 10.3 through 11.x, the displayed status color is determined from the Port Connect State (fddimibPORTConnectState) for each connector. The possible values for this status and the corresponding status colors follow: [CSCdi28566]
Status | Status Color |
---|---|
disabled | brown |
standby | brown |
connecting | blue |
active | green |
The following interface processors and port adaptors are supported:
When you try to open a horizontal-chassis device such as the Cisco 7204, 7206, or 7505 with a Fast Ethernet port adapter installed, the error message "can't read 'DD(port-23.port-26.pos)': no such element in array" is displayed. To fix this, upgrade to the latest Cisco 7000 CiscoView package at http://www.cisco.com/cgi-bin/tablebuild.pl/cview40. [CSCdj16247]
No MIB object is associated with the test port on a CT3IP card. [CSCdj18638]
CiscoView 4.1 always displays the multimode fiber SC type of ATM connector on AIPs, even when the media interface is of another type. [CSCdi53420]
For pa-1e3 and pa-1t3 cards, DS3 Configuration does not appear in the config rport dialog box. Also, DS3 Current Statistics and DS3 Total Statistics do not appear in the monitor rport dialog box. [CSCdj60001]
For 7000/7500 series routers running Cisco IOS Release 10.2 or earlier, the displayed status color is determined from the port's administrative status (ifAdminStatus) and operational status (ifOperStatus) values. This status color will be the same on each connector. For devices running Cisco IOS 10.3 through 11.x, the displayed status color is determined from the Port Connect State (fddimibPORTConnectState) for each connector. The possible values for this status and the corresponding status colors follow: [CSCdi28566]
Status | Status Color |
---|---|
disabled | brown |
standby | brown |
connecting | blue |
active | green |
CiscoView displays an FEIP2-FX interface processor as an FEIP2-TX for all Cisco IOS versions before Release 11.1(11)CA. [CSCdj15831]
The feip-fx card does not appear in CiscoView. When the Cisco 7000 series device comes up, you might see the error message "no such element in array." [CSCdj61077]
For devices running Cisco IOS Release 10.2, a FIP card's PhyA and PhyB LEDs do not appear lit in CiscoView. [CSCdj23023]
When performing the Squeeze operation on a Flash card, the error message "Failed to Squeeze. Try increasing the timeout property under Options in the Main window" might be observed even though the operation succeeds. [CSCdj03172]
On 7513 and 7507 chassis, when the master RSP (Route Switch Processor) is in use, the console port changes color on the CiscoView 4.1 display. However, when a slave RSP is installed, its console port mirrors that of the master, regardless of whether it is in use. [CSCdi49049]
An invalid port level FSIP Config category will appear for devices with MIP cards running Cisco IOS software earlier than Release 11.1. The dialog box shows N/A for variables displayed in it, as these do not apply. [CSCdj23970]
CiscoView might display a 4-port FastSerial port adapter (pa-4t) as a HSSI adapter (pa-ah1t). [CSCdj17487, CSCdj17516]
After an online insertion/removal (OIR) event (also called a "hot-swap"), CiscoView does not show the correct module or port status. The only way to display the correct status is to reopen the device or relaunch CiscoView. [CSCdj39860]
In the DS1 Configuration dialog, dsx1LoopbackConfig is reported with an unknown enumeration. [CSCdj17466]
Ensure you are using the latest LS1010 device package (version 1.8). You can download this package from CCO. [CSCdj59465]
To configure an LECS address for LS1010 from CiscoView, ServiceId needs to be the following: 10.1.3.6.1.4.1.353.1.5.1.<Index>, where Index is the row differentiator for configuring multiple LECS addresses. Index is an integer.
From CiscoView for LS1010, the ATM Traffic Descriptor table does not show any rows. This is an agent bug. [CSCdj00685]
By default, CiscoView 3.1(1) displays two power supplies for a Cisco 7000 router running Cisco IOS Release 10.2 and earlier. With Cisco IOS Release 10.3 and later, power supplies are displayed based on ciscoEnvMonSupplyState values.
Because of the way a master CiscoView contents file is used by the software when multiple CiscoView device package help files are present, the list of files to include when setting up a customized find operation contains multiple items, called CiscoView. [CSCdj62089]
There is a problem with the online help viewer, HyperHelp, intermittently displaying the Help topic window when opening Help>Contents.
When you first open a help topic using Help>Contents and click the Back button, the HyperHelp viewer might display a blank window. This is a HyperHelp bug. [CSCdi04758]
Cisco Connection Online (CCO) is Cisco Systems' primary, real-time support channel. Maintenance customers and partners can self-register on CCO to obtain additional information and services.
Available 24 hours a day, 7 days a week, CCO provides a wealth of standard and value-added services to Cisco's customers and business partners. CCO services include product information, product documentation, software updates, release notes, technical tips, the Bug Navigator, configuration notes, brochures, descriptions of service offerings, and download access to public and authorized files.
CCO serves a wide variety of users through two interfaces that are updated and enhanced simultaneously: a character-based version and a multimedia version that resides on the World Wide Web (WWW). The character-based CCO supports Zmodem, Kermit, Xmodem, FTP, and Internet e-mail, and it is excellent for quick access to information over lower bandwidths. The WWW version of CCO provides richly formatted documents with photographs, figures, graphics, and video, as well as hyperlinks to related information.
You can access CCO in the following ways:
For a copy of CCO's Frequently Asked Questions (FAQ), contact cco-help@cisco.com. For additional information, contact cco-team@cisco.com.
Cisco documentation and additional literature are available in a CD-ROM package, which ships with your product. The Documentation CD-ROM, a member of the Cisco Connection Family, is updated monthly. Therefore, it might be more up to date than printed documentation. To order additional copies of the Documentation CD-ROM, contact your local sales representative or call customer service. The CD-ROM package is available as a single package or as an annual subscription. You can also access Cisco documentation on the World Wide Web at http://www.cisco.com, http://www-china.cisco.com, or http://www-europe.cisco.com.
If you are reading Cisco product documentation on the World Wide Web, you can submit comments electronically. Click Feedback in the toolbar, select Documentation, and click Enter the feedback form. After you complete the form, click Submit to send it to Cisco. We appreciate your comments.
Posted: Wed Oct 9 10:48:25 PDT 2002
All contents are Copyright © 1992--2002 Cisco Systems, Inc. All rights reserved.
Important Notices and Privacy Statement.