cc/td/doc/product/ong/600_sdh/sdh60014
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table Of Contents

Hardware Specifications

Bandwidth

Slot Assignments

Cards

Configurations

Dimensions

Cisco Transport Controller

External LAN Interface

TL1 Craft Interface

Modem Interface

Alarm Interface

BITS Interface

Database Storage

System Timing

Power Specifications

Environmental Specifications

Hardware Specifications


This appendix provides detailed shelf assembly hardware specifications for the CiscoONS15600 SDH.

Appendix topics follow:

Bandwidth

Slot Assignments

Cards

Configurations

Dimensions

Cisco Transport Controller

External LAN Interface

TL1 Craft Interface

Modem Interface

Alarm Interface

BITS Interface

Database Storage

System Timing

Power Specifications

Environmental Specifications

Bandwidth

The ONS15600SDH has the following bandwidth specifications:

Total bandwidth: 320 Gbps

Optical bandwidth: 40 Gbps per slot

Slot Assignments

The ONS15600SDH has the following slot specifications:

Total card slots: 14

Optical cards: Slots 1 to 4, 11 to 14

TSC (Timing and Shelf Controller): Slots 5, 10

CXC (Core Cross Connect): Slots 6/7, 8/9

Cards

The ONS15600SDH has the following cards:

TSC

CXC

OC48/STM16LR161550

OC48/STM16SR161310

OC192/STM64LR41550

OC192/STM64SR41310

Configurations

The ONS15600SDH has the following possible configurations:

1+1 automatic protection switching (APS) (point-to-point and linear)

Two-fiber subnetwork connection protection (SNCP)

Extended SNCP Mesh Network

Two-fiber multiplex section-shared protection ring (MS-SPRing)

Unprotected

Dimensions

The ONS15600SDH has the following dimensions:

Height: 83.9 in. (2130 mm)

Width: 23.6 in. (600 mm)

Depth: 23.6 in. (600 mm)

Weight: 500 lb (226.8 kg) (without cards)

Cisco Transport Controller

Cisco Transport Controller has the following specifications:

10/100 BaseT

TSC access: RJ-45 connector

Backplane access: RJ-45 connector

External LAN Interface

The ONS15600SDH external LAN interface has the following specifications:

10/100 BaseT Ethernet

Backplane access: RJ-45 connector

TL1 Craft Interface

The ONS15600SDH TL1 craft interface has the following specifications:

Speed: 9600 bps

Backplane (customer access panel [CAP]) access: EIA/TIA-232 DB-9 type connector

Modem Interface

The ONS15600SDH modem interface has the following specifications:

Hardware flow control

Backplane (CAP) access: EIA/TIA-232 DB-9 type connector

Alarm Interface

The ONS15600SDH alarm interface has the following specifications:

Visual: Critical, Major, Minor, Remote

Audible: Critical, Major, Minor, Remote

Alarm contacts: 0.045 mm, -48 VDC, 50 mA

Backplane (CAP) access: Alarm pin fields

BITS Interface

The ONS15600SDH building integrated timing supply (BITS) interface has the following specifications:

2 E1 BITS inputs

2 derived STM-N outputs

Database Storage

The ONS15600SDH has the following database storage specifications:

Nonvolatile memory: 512 MB, IDE FLASH memory

System Timing

The ONS15600SDH has the following system timing specifications:

Holdover stability: Stratum 3E per ITU-T G.813

Free running accuracy: ± 4.6 ppm

Reference: External BITS, line, internal

Power Specifications

The ONS15600SDH has the following power specifications:

Input voltage: -48 to -60 VDC (operational from -40.5 to -72 VDC)

Input current: 100 A per feed (six feeds provided)

Power consumption: 2200W (maximum draw with cards)

Power terminals: Lug

TableB-1 lists the power requirements for each card.

Table B-1 Power Requirements for Individual Cards 

Card Type
Card Name
Watts
Control Cards

TSC

58

CXC

165

Optical Cards

OC48/STM16 LR16 1550

170

OC48/STM16 SR16 1310

180

OC192/STM64 LR4 1550

165

OC192/STM64 SR4 1310

180


TableB-2 lists the power requirements for an individual fan in the fan-tray assembly.

Table B-2 Power Requirements for Individual Fans

Condition
Watts
Amperes
BTU/Hr.
Min. at 48 V (ambient temperature less than 25C)

12

0.25

41

Max. at 48 V (ambient temperature greater than 25C)

46

0.95

157


Environmental Specifications

The ONS15600SDH has the following environmental specifications:

Operating temperature: 23 to 122 degrees Fahrenheit (-5 to +50 degrees Celsius)

Operating humidity: 5 to 95 percent, noncondensing


hometocprevnextglossaryfeedbacksearchhelp

Posted: Thu Feb 26 17:27:34 PST 2004
All contents are Copyright © 1992--2004 Cisco Systems, Inc. All rights reserved.