Table Of Contents
Hardware Specifications
This appendix provides detailed shelf assembly hardware specifications for the CiscoONS15600 SDH.
Appendix topics follow:
• Cards
• Environmental Specifications
Bandwidth
The ONS15600SDH has the following bandwidth specifications:
•Total bandwidth: 320 Gbps
•Optical bandwidth: 40 Gbps per slot
Slot Assignments
The ONS15600SDH has the following slot specifications:
•Total card slots: 14
•Optical cards: Slots 1 to 4, 11 to 14
•TSC (Timing and Shelf Controller): Slots 5, 10
•CXC (Core Cross Connect): Slots 6/7, 8/9
Cards
The ONS15600SDH has the following cards:
•TSC
•CXC
•OC48/STM16LR161550
•OC48/STM16SR161310
•OC192/STM64LR41550
•OC192/STM64SR41310
Configurations
The ONS15600SDH has the following possible configurations:
•1+1 automatic protection switching (APS) (point-to-point and linear)
•Two-fiber subnetwork connection protection (SNCP)
•Extended SNCP Mesh Network
•Two-fiber multiplex section-shared protection ring (MS-SPRing)
•Unprotected
Dimensions
The ONS15600SDH has the following dimensions:
•Height: 83.9 in. (2130 mm)
•Width: 23.6 in. (600 mm)
•Depth: 23.6 in. (600 mm)
•Weight: 500 lb (226.8 kg) (without cards)
Cisco Transport Controller
Cisco Transport Controller has the following specifications:
•10/100 BaseT
•TSC access: RJ-45 connector
•Backplane access: RJ-45 connector
External LAN Interface
The ONS15600SDH external LAN interface has the following specifications:
•10/100 BaseT Ethernet
•Backplane access: RJ-45 connector
TL1 Craft Interface
The ONS15600SDH TL1 craft interface has the following specifications:
•Speed: 9600 bps
•Backplane (customer access panel [CAP]) access: EIA/TIA-232 DB-9 type connector
Modem Interface
The ONS15600SDH modem interface has the following specifications:
•Hardware flow control
•Backplane (CAP) access: EIA/TIA-232 DB-9 type connector
Alarm Interface
The ONS15600SDH alarm interface has the following specifications:
•Visual: Critical, Major, Minor, Remote
•Audible: Critical, Major, Minor, Remote
•Alarm contacts: 0.045 mm, -48 VDC, 50 mA
•Backplane (CAP) access: Alarm pin fields
BITS Interface
The ONS15600SDH building integrated timing supply (BITS) interface has the following specifications:
•2 E1 BITS inputs
•2 derived STM-N outputs
Database Storage
The ONS15600SDH has the following database storage specifications:
•Nonvolatile memory: 512 MB, IDE FLASH memory
System Timing
The ONS15600SDH has the following system timing specifications:
•Holdover stability: Stratum 3E per ITU-T G.813
•Free running accuracy: ± 4.6 ppm
•Reference: External BITS, line, internal
Power Specifications
The ONS15600SDH has the following power specifications:
•Input voltage: -48 to -60 VDC (operational from -40.5 to -72 VDC)
•Input current: 100 A per feed (six feeds provided)
•Power consumption: 2200W (maximum draw with cards)
•Power terminals: Lug
TableB-1 lists the power requirements for each card.
TableB-2 lists the power requirements for an individual fan in the fan-tray assembly.
Environmental Specifications
The ONS15600SDH has the following environmental specifications:
•Operating temperature: 23 to 122 degrees Fahrenheit (-5 to +50 degrees Celsius)
•Operating humidity: 5 to 95 percent, noncondensing
Posted: Thu Feb 26 17:27:34 PST 2004
All contents are Copyright © 1992--2004 Cisco Systems, Inc. All rights reserved.
Important Notices and Privacy Statement.