Table Of Contents
CHG Commands
This chapter provides change (CHG) commands for the Cisco ONS 15454, Cisco ONS 15310-MA, and Cisco ONS 15600.
5.1 CHG-ACCMD-<MOD_TACC>
(Cisco ONS 15454, ONS 15310-MA, ONS 15600) The Change Test Access Mode for the DS1, DS3I, E1, E3, STS1, STS12C, STS192C, STS24C, STS3C, STS48C, STS6C, STS9C, T1, T3, VT1, or VT2 (CHG-ACCMD-<MOD_TACC>) command changes the test access (TACC) mode for the circuit being tested. This can be a change from monitoring the data to inserting data into the synchronous transport signal (STS). For more information about TACC, refer to the Cisco ONS SONET TL1 Reference Guide. See Table 27-1 for supported modifiers by platform.
Usage Guidelines
This command can only be applied to an existing test access point (TAP) connection.
Caution For this command to be applicable, first create the TAP using the ED-<MOD_PATH> command. Intrusive test access modes are traffic-affecting. If a facility/path is connected to a TAP in an intrusive test access mode, it is forced to go into the Out of Service, Maintenance (OOS-MT) state. The forced transition could be traffic-affecting. The present state of the facility/path is stored by the network element (NE) and is restored when the TAP connection is terminated. Test access connections are dropped automatically if the TL1 session is terminated or is timed out.
Note•If there is no TAP connection, a DENY error message is returned.
•If a requested condition already exists, a SRCN error message is returned.
•If a requested access configuration is invalid, a SRAC error message is returned.
•If a requested TAP does not exist, a RTEN error message is returned.
CategoryTroubleshooting and Test Access
SecurityMaintenance
Input FormatCHG-ACCMD-<MOD_TACC>:[<TID>]:<TAP>: <CTAG>::<MD>;
Input ExampleCHG-ACCMD-STS1:CISCO:8:123::MONE;
Input Parameters
5.2 CHG-EQPT
(Cisco ONS 15454) The Change Equipment (CHG-EQPT) command performs an in-service upgrade from low density (LD) electrical cards (DS1 [DS1-14, DS1N-14], DS3 [DS3-12, DS3N-12, DS3NE-12], EC1, and DS3XM-6) to high density (HD) electrical cards (DS1/E1-56, DS3/EC1-48, and DS3XM-12).
Usage Guidelines
•For Software Release 6.0 and later, only limited upgrades are supported, such as upgrading one LD DS3-12 card to one HD DS3/EC1-48 card.
•Optical (OC-N) card upgrades and downgrades are supported with the limitations of the MRC-12 card.
•Compatible equipment types for card upgrade:
–DS3XM-6 to DS3XM-12
–DS-3/DS3-N/DS3-E/DS3N-E to DS3/EC1-48
–DS-1/DS1-N to DS1/E1-56
•Provisioning rules for card upgrade:
–DS1-14 and DS1N-14 cards that are provisioned in Slot 1, 2, 3, 15, 16, or 17 should be upgraded to DS1/E1-56.
–DS1-14 and DSN-14 cards that are provisioned in Slot 4, 5, 6, 12, 13, or 14 will fail when upgrading to DS1/E1-56.
–DS3-12, DS3N-12, DS3E-12, and DS3N-12E cards that are provisioned in Slot 1, 2, 3, 15, 16, or 17 can be upgraded to DS3/EC1-48.
–DS3-12, DS3N-12, DS3E-12, and DS3N-12E cards that are provisioned in Slot 4, 5, 6, 12, 13, or 14 will fail when upgrading to DS3/EC1-48.
–Two upgradable cards provisioned in a 1:1 protection group cannot be upgraded.
CategoryEquipment
SecurityMaintenance
Input FormatCHG-EQPT:[<TID>]:<AID>:<CTAG>::<EQPTTYPE>:[PPMTYPE=PPMTYPE>],
[PPMNUM=<PPMNUM>],[PORTNUM=<PORTNUM>],[PORTRATE=<PORTRATE>];Input ExampleCHG-EQPT::SLOT-14:1::MRC-2.5G-4:PPMTYPE=PPM-1,PPMNUM=1,PORTNUM=1,
PORTRATE=OC48;Input Parameters
<SRC>
The source access identifier from the "EQPT" section.
<EQPTTYPE>
The equipment type to be upgraded. The parameter type is EQUIPMENT_TYPE.
•10DME-C
10DME-C card
•10DME-L
10DME-L card
•32DMX
(ONS 15454) 32 channel demultiplexer
•32DMX-L
(ONS 15454) 32 channel demultiplexer unit for L-band
•32DMX-O
(ONS 15454) 32 channel unidirectional optical demultiplexer
•32MUX-O
(ONS 15454) 32 channel unidirectional optical multiplexer
•32WSS
(ONS 15454) 32 channel optical wavelength selective switch
•32WSS-L
(ONS 15454) 32 channel wavelength switch selector unit for L-band
•4MD-xx.x
(ONS 15454) Optical multiplexer/demultiplexer with 4 channels
•AD-1B-xx.x
(ONS 15454) Optical add/drop multiplexed (OADM) 1 band filter
•AD-1C-xx.x
(ONS 15454) Optical add/drop multiplexed (OADM) 1 channel filter
•AD-2C-xx.x
(ONS 15454) Optical add/drop multiplexed (OADM) 2 channel filter
•AD-4B-xx.x
(ONS 15454) Optical add/drop multiplexed (OADM) 4 band filter
•AD-4C-xx.x
(ONS 15454) Optical add/drop multiplexed (OADM) 4 channel filter
•AIC-I
(ONS 15454) AIC-I card
•ASAP
(ONS 15600) Any service any port carrier card with 4 PIM slots
•CE-1000-4
(ONS 15454) CE-1000-4 card
•CE-100T-8
(ONS 15454, ONS 15310-CL, ONS 15310-MA) Eight port 100T card
•CTX2500
(ONS 15310-MA) CTX2500 card
•DS1
(ONS 15454) DS1 card
•DS1-28/DS3-EC1-3
(ONS 15310-MA) DS1-28/DS3-EC1-3 card
•DS1-84/DS3-EC1-3
(ONS 15310-MA) DS1-84/DS3-3 card
•DS1/E1-56
(ONS 15454) DS1/E1-56 card
•DS1N
(ONS 15454) DS1N card
•DS3
(ONS 15454) DS3 card
•DS3/EC1-48
(ONS 15454) DS3/EC1-48 card
•DS3i-N-12
(ONS 15454) DS3i-N-12 card
•DS3N
(ONS 15454) DS3N card
•DS3NE
(ONS 15454) DS3NE card
•DS3XM-6
(ONS 15454) DS3XM-6 card
•DS3XM-12
(ONS 15454) DS3XM-12 card
•E1000-2
(ONS 15454) E1000-2 card
•E1000-2-G
(ONS 15454) E1000-2-G card
•E100T
(ONS 15454) E100T card
•EC1
(ONS 15454) EC1 card
•FC_MR-4
(ONS 15454) FC_MR-4 card
•FILLER-CARD
Blank Filler card
•G1K-4
(ONS 15454) Four port G1000 card
•ML100T-8
(ONS 15310-CL, ONS 15310-MA) Mapper card
•ML1000-2
(ONS 15454) ML-Series two port gigabit Ethernet card
•ML100T-12
(ONS 15454) ML-Series 12 port FSTE card
•ML100X-8
(ONS 15454) Eight port 100T card with optical interface
•MMU
(ONS 15454) Multiring/mesh upgrade unit
•MRC-12
(ONS 15454) 12 port multirate optical card
•MRC-2.5G-4
(ONS 15454) 4-port MRC 2.5G card
•MRC-2.5G-12
(ONS 15454) 12-port MRC 2.5G card
•OC3
(ONS 15454) OC-3 card
•OC3-8
(ONS 15454) Eight port OC-3 card
•OC12
(ONS 15454) OC-12 card
•OC12-4
(ONS 15454) Four port OC-12 card
•OC48
(ONS 15454, ONS 15600) OC-48 card
•OC48-16
(ONS 15454) 16 port OC-48 card
•OC192
(ONS 15454, ONS 15600) OC-192 card
•OC192-4
(ONS 15454) Four port OC-192 card
•OC192-XFP
(ONS 15454) One port OC-192 XFP
•OPT-AMP-L
(ONS 15454) Optical preamplifier unit for L-Band
•OPT-BST
(ONS 15454) Optical booster amplifier
•OPT-BST-L
(ONS 15454) Optical booster unit for L-Band
•OPT-PRE
(ONS 15454) Optical preamplifier
•OSC-CSM
(ONS 15454) Optical service channel (OSC) with combiner/separator Module (SCM)
•OSCM
(ONS 15454) Optical service channel module
•PIM-1
(ONS 15600) One port pluggable interface module
•PIM-4
(ONS 15600) Four port pluggable interface module
•PPM-1
(ONS 15454, ONS 15600, ONS 15310-CL, ONS 15310-MA) Pluggable port module with one SFP port
•SHELF
Shelf entity
•SSXC
(ONS 15600) Cross-connect card
•TCC
(ONS 15454) TCC card
•TXP_MR_10E
(ONS 15454) 10-Gbps multirate transponder-100-GHz-tunable xx.xx-xx.xx card
•TXP_MR_10E_C
(ONS 15454) 10-Gbps multirate transponder-100-GHz-tunable xx.xx-xx.xx card for C-band
•TXP_MR_10E-L
(ONS 15454) 10-Gbps multirate transponder-100-GHz-tunable xx.xx-xx.xx card for L-band
•TXP_MR_10G
(ONS 15454) 10-Gbps multirate transponder-100-GHz-tunable xx.xx-xx.xx card
•TXP_MR_2.5G
(ONS 15454) 2.5-Gbps multirate transponder-100-GHz-tunable xx.xx-xx.xx card
•TXPP_MR_2.5G
(ONS 15454) 2.5-Gbps multirate transponder-protected-100-GHz-tunable xx.xx-xx.xx card
•UNKNOWN
Unknown equipment type
•UNPROVISIONED
Unprovisioned type
•XC10G
(ONS 15454) XC10G card
•XCVT
(ONS 15454) XCVT card
•XC-VXC-10G
(ONS 15454) XC-VXC-10G card
<PPMTYPE>
Identifies the pluggable port module type.
•PPM-1
Single-port PPM
<PPMNUM>
Identifies the pluggable port module number.
•1
PPM No. 1
•2
PPM No. 2
•3
PPM No. 3
•4
PPM No. 4
•5
PPM No. 5
•6
PPM No. 6
•7
PPM No. 7
•8
PPM No. 8
•9
PPM No. 9
•10
PPM No. 10
•11
PPM No. 11
•12
PPM No. 12
<PORTNUM>
Identifies the port number, which is used on the entity port with PPM.
•1
Port No. 1
<PORTRATE>
Identifies the port rate, which is used to specify the port rate of the multi-rate card.
•OC3
OC-3 rate
•OC12
OC-12 rate
•OC48
OC- 48 rate