Table Of Contents
Access Identifiers
This chapter describes the access identifiers (AIDs) of TL1 commands and autonomous messages for the
Cisco ONS 15454, Cisco ONS 15310-CL, Cisco ONS 15310-MA, and Cisco ONS 15600.The AID code directs an input command to its intended physical or data entity inside the network element (NE). Equipment modules and facilities are typical examples of entities addressed by the access code. The AIDs in this section apply to the SONET ONS 15454, ONS 15310-CL, ONS 15310-MA, and ONS 15600, except where noted.
25.1 ALL
25.2 AidUnionId
25.3 AidUnionId1
25.4 BAND
(Cisco ONS 15454 only) The BAND AID is used to access Optical Multiplex Section (OMS) layer of optical networking units.
25.5 BANDWL
Band wavelength. Identifies a wavelength channel included in any of the lower layer OMS facilities.
25.6 BITS
AID for building integrated timing supply (BITS).
25.7 BLSR
(ONS 15454, ONS 15600) BLSR AIDs are used to access the specific BLSR of the NE.
25.8 CHANNEL
(Cisco ONS 15454 only) Accesses the optical channels (OCH) layer of optical networking units.
25.9 COM
Common
25.10 CrossConnectId
25.11 CrossConnectId1
25.12 DS1
(Cisco ONS 15454 only) Used to access the DS-1 frame layer of the DS3XM. The format is DS1-[SLOT]-[DS3PORT]-[DS1PORT].
25.13 ENV
The environmental AID for the AIC-I cards."IN" is used for environmental alarms. "OUT" is used for environmental controls.
25.14 EQPT
Equipment AIDs are used to access specific cards.
In the ONS 15454, the OC-48/OC-192 cards are only used in Slots 5, 6, 12, and 13.
In the ONS 15600, Slots 1 through 4 and Slots 11 through 14 are used for optical cards. Slots 5 and 10 are reserved for the TSC cards. Slots 6, 7, 8, and 9 are reserved for the SSXC cards.
In the ONS 15310-CL, Slot-1 is used for I/O cards. Slot-2 is the 15310-CL-CTX card.
In the ONS 15310-MA, Slots 1, 2, 5, and 6 are used for I/O Cards. Slots 3 and 4 are reserved for the CTX2500 card.
25.15 FACILITY
(Cisco ONS 15454, ONS 15327, ONS 15310-CL, ONS 15310-MA, ONS 15600) Facility AIDs are used to access specific ports.
Note Because the ONS 15310-CL and ONS 15310-MA support more than one type of facility per slot, the FAC-AID format is not supported. The formats Tn-, EC1- , and OCn- are used instead.
ONS 15454 and ONS 15600 Facility AID format:
•Format for optical and EC1 facilities without PPM: FAC-[SLOT]-[PORT]
•Format for optical facilities with PPM: FAC-[SLOT]-[PPM]-[PORT]
•Format for optical facilities with PPM and PIM: FAC-[SLOT]-[PIM]-[PPM]-[PORT]
•Format for DS1-flavored electrical facilities: FAC-[SLOT]-[PORT]
•Format for DS3-flavored (including DS3i) electrical facilities: FAC-[SLOT]-[PORT]
•Format for packet-over-SONET (POS) ports: VFAC-[SLOT]-[PORT]
•Format for POS ports with PIMs and PPMs: VFAC-[SLOT]-[PIM]-[PPM]-[PORT]
ONS 15310-CL and ONS 15310-MA Facility AID format:
•Format for optical facilities without PPMs: OCn-[SLOT]-[PORT]
•Format for optical facilities with PPMs: OCn-[SLOT]-[PPM]-[PORT]
•Format for EC1 facilities: EC1-[SLOT]-[PORT]
•Format for DS1-flavored electrical facilities: T1-[SLOT]-[PORT]
•Format for DS3-flavored electrical facilities: T3-[SLOT]-[PORT]
•Format for POS ports: VFAC-[SLOT]-[PORT]
•Format for FSTE Ethernet facilities: FSTE-[SLOT]-[PORT]
25.16 IPADDR
IP Address
25.17 LINE
(Cisco ONS 15454 only) The LINE AID is used to access the Optical Transport Section (OTS) layer of optical network units. Applicable only to AD-1B-xx.x, AD-4B-xx.x, AD-1C-xx.x, AD-2C-xx.x, AB-4C-xx.x, OSC-CSM, OSCM, OPT-BST, OPT-PRE, 4MD-xx.x, 32MUX-O, and 32DMX-O cards. The format is LINE-[SLOT]-[PORT]-[DIRECTION].
25.18 LINEWL
Line wavelength. Identifies a wavelength channel included in any of the lower layer OTS facilities.
25.19 LNKTERM
Link termination AIDs are used to access the termination points of a provisionable patchcord.
25.20 OPM
OPM AIDs represent the single wavelength inside an optical power monitoring object.
25.21 OSC
(Cisco ONS 15454 only) OSC AIDs are used to access the OSC of the NE.
25.22 PRSLOT
(Cisco ONS 15454 only) Valid protection slots for the electrical cards.
25.23 RFILE
(ONS 15454, ONS 15310-CL, ONS 15310-MA) File transfer type.
Table 25-23 RFILE
Pattern DescriptionRFILE-DB
Transferring the system database.
RFILE-LOG
Transferring a log file.
RFILE-PKG
Transferring a software package.
25.24 SHELF
(ONS 15454, ONS 15310-CL, ONS 15310-MA) Identifies a shelf within a node. SHELF is applicable only to nodes that are set to MULTISHELF or MULTISHELFETH mode.
Table 25-24 SHELF
Pattern DescriptionSHELF-ALL
All of the shelves in the node.
SHELF-{1-8}
A specific shelf in the node (shelf 1 through 8).
25.25 STS
SONET frame-level AID set:
•STS AID format for optical and EC1 facilities without PPM: STS-[SLOT]-[PORT]-[STS]
•STS AID format for optical facilities with PPMs: STS-[SLOT]-[PPM]-[PORT]-[STS]
•STS AID format for optical facilities with PIMs and PPMs: STS-[SLOT]-[PIM]-[PPM]-[PORT]-[STS]
•STS AID format for DS1 electrical facilities: STS-[SLOT]-[STS]
•STS AID format for DS3 (except DS3i) electrical facilities: STS-[SLOT]-[PORT]-[STS]
•STS AID format for DS3i electrical facilities: STS-[SLOT]-[STS]
•STS AID format for G1K-4 card Gigabit Ethernet (GIGE) facilities: FAC-[SLOT]-[PORT]
25.26 SYN
Synchronization AIDs
25.27 SYN_SRC
Synchronization source
25.28 SYNC_REF
(Cisco ONS 15454, ONS 15327, ONS 15310-CL, ONS 15310-MA, ONS 15600) Synchronization AIDs.
25.29 SYNCSW
New synchronization reference that will be used.
Table 25-29 SYNCSW
Pattern DescriptionINT
Internal clock. The INT value is only applied for the SYNC-NE AID on the OPR-SYNCSW command.
PRI
Primary timing reference.
SEC
Secondary timing reference.
25.30 UDC
(ONS 15454, ONS 15310-CL, ONS 15310-MA) UDC AIDs for F-UDC and DCC-UDC channels on the AIC-I card.
25.31 VT
(ONS 15454, ONS 15310-CL, ONS 15310-MA) Virtual tributary.
•VT1 AID format for optical and EC1 facilities without PPM: VT1-[SLOT]-[PORT]-[STS]-[VTG]-[VTN]
•VT1 AID format for optical facilities with PPM: VT1-[SLOT]-[PPM]-[PORT]-[STS]-[VTG]-[VTN]
•VT1 AID format for DS1 electrical facilities: VT1-[SLOT]-[STS]-[VTG]-[VTN]
•VT1 AID format for DS3 electrical facilities: VT1-[SLOT]-[PORT]-[STS]-[VTG]-[VTN]
25.32 WDMANS
(Cisco ONS 15454 only) This AID is used to access the automatic optical node setup (AONS) application of the NE.
Table 25-32 WDMANS
Pattern DescriptionAONS-{E,W}
Automatic optical node setup identifier (based on ring direction)
WDMANS-{E,W}
Automatic optical node setup identifier (based on ring direction)
25.33 WLEN
(Cisco ONS 15454 only) This AID represents the single wavelength inside an external facility. If the facility is of type OTS (line), the wavelengths contained are all the available in the node (currently 32). If the facility is of type OCH (CHAN), the wavelength is just one and it is the same of the correspondent wavelength customized for that channel.
Posted: Tue Jul 10 11:16:24 PDT 2007
All contents are Copyright © 1992--2007 Cisco Systems, Inc. All rights reserved.