cc/td/doc/product/ong/15400/r60docs
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table Of Contents

INIT Commands

15.1  INIT-REG-<MOD2>

15.2  INIT-SYS


INIT Commands


This chapter provides INIT (initialize) commands for the Cisco ONS 15454, ONS 15327, ONS 15600 and ONS 15310-CL.

15.1  INIT-REG-<MOD2>

Initialize Register (10GFC, 10GIGE, 1GFC, 1GFICON, 2GFC, 2GFICON, CLNT, D1VIDEO, DS1, DV6000, E1, E3, E4, EC1, ESCON, ETRCLO, FSTE, G1000, GFPOS, GIGE, HDTV, ISC1, OC12, OC192, OC3, OC48, OCH, OMS, OTS, POS, STS1, STS12C, STS18C, STS192C, STS24C, STS36C, STS3C, STS48C, STS6C, STS9C, T1, T3, VC12, VC3, VT1, VT2)

See Table 27-1 for supported modifiers by platform.

Usage Guidelines

Cisco ONS 15454, ONS 15327, ONS 15600, ONS 15310-CL

This command initializes the performance monitoring (PM) registers.


Note•The time period is always the current time period, and the previous time period counts are not cleared; therefore, both <MONDAT> and <MONTM> are not supported in this command.

•Unless otherwise stated, DS1 cards are the only cards that support the RCV and TRMT directions.

•INIT-REG-<MOD2> can also be used to initialize the RMON-managed raw data.


Category

Performance

Security

Maintenance

Related Commands

ALW-PMREPT-ALL

DLT-<MOD1PAYLOAD>

DLT-FFP-<MOD2DWDMPAYLOAD>

DLT-FFP-<OCN_TYPE>

DLT-RMONTH-<MOD2_RMON>

ED-<GIGE_TYPE>

ED-<MOD1FCPAYLOAD>

ED-<MOD1FICONPAYLOAD>

ED-<MOD2DWDMPAYLOAD>

ED-<OCN_TYPE>

ED-ALS

ED-DS1

ED-EC1

ED-FFP-<MOD2DWDMPAYLOAD>

ED-FFP-<OCN_TYPE>

ED-FSTE

ED-G1000

ED-GFP

ED-HDLC

ED-POS

ED-T1

ED-T3

ED-TRC-<MOD2DWDMPAYLOAD>

ED-TRC-<OCN_TYPE>

ENT-<MOD1PAYLOAD>

ENT-FFP-<MOD2DWDMPAYLOAD>

ENT-FFP-<OCN_TYPE>

ENT-RMONTH-<MOD2_RMON>

INH-PMREPT-ALL

OPR-ALS

OPR-LPBK-<MOD2>

OPR-PROTNSW-<MOD2DWDMPAYLOAD>

OPR-PROTNSW-<OCN_TYPE>

REPT PM <MOD2>

RLS-LPBK-<MOD2>

RLS-PROTNSW-<MOD2DWDMPAYLOAD>

RTRV-FAC

RTRV-FFP-<MOD2DWDMPAYLOAD>

RTRV-FFP-<OCN_TYPE>

RTRV-FSTE

RTRV-G1000

RTRV-GFP

RTRV-GIGE

RTRV-HDLC

RTRV-PM-<MOD2>

RTRV-PMMODE-<STS_PATH>

RTRV-PMSCHED-<MOD2>

RTRV-PMSCHED-ALL

RTRV-POS

RTRV-PROTNSW-<MOD2DWDMPAYLOAD>

RTRV-PROTNSW-<OCN_TYPE>

RTRV-RMONTH-<MOD2_RMON>

RTRV-T1

RTRV-T3

RTRV-TH-<MOD2>

RTRV-TH-ALL

RTRV-TRC-<MOD2DWDMPAYLOAD>

RTRV-TRC-<OCN_TYPE>

SCHED-PMREPT-<MOD2>

SET-ALMTH-<MOD2>

SET-PMMODE-<STS_PATH>

SET-TH-<MOD2>

RLS-PROTNSW-<OCN_TYPE>

RMV-<MOD2>

RST-<MOD2>

RTRV-<MOD1FCPAYLOAD>

RTRV-<MOD1FICONPAYLOAD>

RTRV-<MOD2DWDMPAYLOAD>

RTRV-<OCN_TYPE>

RTRV-10GIGE

RTRV-ALMTH-<MOD2>

RTRV-ALS

RTRV-DS1

RTRV-EC1


Input Format

INIT-REG-<MOD2>:[<TID>]:<AID>:<CTAG>::<MONTYPE>,,[<LOCN>],[<DIRN>],[<TMPER>]
[,,];

Input Examples

INIT-REG-OC3:CISCO:FAC-1-1:1234::CVL,,NEND,BTH,15-MIN;

Input Parameters

Table 15-1 INIT-REG-<MOD2> Input Parameters 

Parameter and Values
Description

AID

Access identifier from the "ALL" section. All of the STS, VT1, Facility and DS1 AIDS are supported

MONTYPE

Monitored type

Parameter type is ALL_MONTYPE—monitoring type list

•AISSP

Alarm Indication Signal Seconds—Path

•ALL

All possible values

•BBE-PM

OTN—Background Block Errors—Path Monitor Point

•BBE-SM

OTN—Background Block Errors—Section Monitor Point

•BBER-PM

OTN—Background Block Error Ratio—Path Monitor Point expressed as 1/10th of a percentage.

•BBER-SM

OTN—Background Block Error Ratio—Section Monitor Point expressed as 1/10th of a percentage.

•BIEC

FEC—Bit Errors Corrected

•CGV

8B10B—Code Group Violations

•CSSP

Controlled Slip Seconds—Path (DSXM-12 FDL/T1.403 PM count)

•CVCPP

Coding Violations—CP-Bit Path

•CVL

Coding Violations—Line

•CVP

Coding Violations—Path

•CVS

Coding Violations—Section

•CVV

Coding Violations—Section

•DCG

8B10B—Data Code Groups

•ESAP

Errored Second Type A-Path (DS3XM-12 DS1 PM count)

•ESBP

Errored Second Type B-Path (DS3XM-12 DS1 PM count)

•ESCPP

Errored Seconds—CP—Bit Path

•ESL

Errored Seconds—Line

•ESNPFE

Errored Second -Network Path (DS3XM-12 DS1 PM count)

•ESP

Errored Seconds—Path

•ES-PM

OTN—Errored Seconds—Path Monitor Point

•ES-SM

OTN—Errored Seconds—Section Monitor Point

•ESR

Errored Second—Ratio

•ESR-PM

Errored Seconds Ratio—Path monitor Point expressed as 1/10th of a percentage

•ESR-SM

Errored Seconds Ratio—Section monitor Point expressed as 1/10th of a percentage

•ESS

Errored Seconds—Section

•ESV

Errored Seconds—VT Path

•etherStatsBroadcastPkts

The total number of good packets received that were directed to a multicast address

•etherStatsCollisions

Number of transmit packets that are collisions

•etherStatsCRCAlignErrors

The total number of packets received that have a length (excluding framing bits, but including FCS octets) of between 64 and 1518 octets

•etherStatsDropEvents

Number of received frames dropped at the port level

•etherStatsFragments

The total number of packets received that were less than 64 octets

•etherStatsJabbers

The total number of packets received that are longer than 1518 octets

•etherStatsOctets

The total number of octets of data

•etherStatsOversizePkts

The total number of packets received that are longer than 1518 octets

•etherStatsPkts

The total number of packets (including bad packets, broadcast packets, and multicast packets) received

•etherStatsUndersizePkts

The total number of packets received that are less than 64 octets

•FCP

Failure Count—Line

•FC-PM

OTN—Failure Count—Path Monitor Point

•FC-SM

OTN—Failure Count—Section Monitor Point

•HP-AR

Availability Ratio

•HP-BBE

High-Order Path Background Block Error

•HP-BBER

High-Order Path Background Block Error Ratio

•HP-EB

High-Order Path Errored Block

•HP-ES

High-Order Path Errored Second

•HP-ESA

High-Order Path Errored Seconds - A

•HP-ESB

High-Order Path Errored Seconds - B

•HP-ESR

High-Order Path Errored Second Ratio

•HP-FC

High-Order Path Failure Count

•HP-NPJC-PDET

High Order Path Negative Pointer Justification Count

•HP-NPJC-PGEN

High Order Path, Negative Pointer Justification Count

•HP-OI

Outage Intensity

•HP-PJCDIFF

High Order Path Pointer Justification Count Difference

•HP-PJCS-PDET

High Order Path Pointer Justification Count

•HP-PJCS-PGEN

High Order Path Pointer Justification Count Seconds

•HP-PPJC-PDET

High Order Path Positive Pointer Justification Count

•HP-PPJC-PGEN

High Order Path, Positive Pointer Justification Count

•HP-SEPI

The number of SEP events in available time

•HP-SES

High-Order Path Severely Errored Seconds

•HP-SESR

High-Order Path Severely Errored Second Ratio

•HP-UAS

High-Order Path Unavailable Seconds

•ifInBroadcastPkts

Number of broadcast packets received since the last counter reset

•ifInDiscards

The number of inbound packets

•ifInErrorBytePktss

Receive Error Byte

•ifInErrors

The number of inbound packets (or transmission units) that contained errors

•ifInFramingErrorPkts

Receive Framing Error

•ifInJunkInterPkts

Receive Interpkt Junk

•ifInMulticastPkts

Number of multicast packets received since the last counter reset

•ifInOctets

Number of bytes transmitted since the last counter reset

•ifInUcastPkts

Number of unicast packets received since the last counter reset

•ifOutBroadcastPkts

Number of broadcast packets transmitted

•ifOutDiscards

The number of outbound packets

•ifOutErrors

The number of outbound packets (or transmission units) that could not be transmitted because of errors

•ifOutMulticastPkts

Number of multicast packets transmitted

•ifOutPayloadCrcErrors

Received payload CRC errors

•ifOutUcastPkts

Number of unicast packets transmitted

•IOS

8B10B- Idle Ordered Sets

•IPC

Invalid Packet Count

•LBCL-AVG

Average Laser Bias current in uA

•LBCL-MAX

Maximum Laser Bias current in uA

•LBCL-MIN

Minimum Laser Bias current in uA

•LBCN

Normalized Laser Bias Current for OC3-8

•LBCN-HWT

Laser Bias Current

•LBCN-LWT

Laser Bias Current

•LOSSL

Loss of Signal Seconds—Line

•LP-BBE

Low-Order Path Background Block Error

•LP-BBER

Low-Order Path Background Block Error Ratio

•LP-EB

Low-Order Path Errored Block

•LP-ES

Low-Order Path Errored Second

•LP-ESA

Low-Order Path Errored Seconds-A

•LP-ESB

Low-Order Path Errored Seconds-B

•LP-ESR

Low-Order Path Errored Second Ratio

•LP-FC

Low-Order Path Failure Count

•LP-NPJC-DET

Low-Order Negative Pointer Justification Count, Detected

•LP-NPJC-GEN

Low Order Negative Pointer Justification Count, Generated

•LP-PPJC-DET

Low-Order Positive Pointer Justification Count, Detected

•LP-PPJC-GEN

Low-Order positive Pointer Justification Count, Generated

•LP-SEP

Low-Order Path Severely Errored Period

•LP-SEPI

Low-Order Path Severely Errored Period Intensity

•LP-SES

Low-Order Path Severely Errored

•LP-UAS

Low-Order Path Unavailable Seconds

•MS-PSC

Protection switch count

•MS-PSD

Protection switch duration

•NIOS

8B10B—Non Idle Ordered Sets

•NPJC-PDET

PPJC-PDET:Negative Pointer Justification

•NPJC-PGEN

PPJC-PGEN:Negative Pointer Justification

•OPR-AVG

Average Receive Power in 1/10 uW

•OPR-MAX

Maximum Receive Power in 1/10 uW

•OPR-MIN

Minimum Receive Power in 1/10 uW

•OPRN

Normalized Optical Receive Power for OC3-8

•OPRN-MAX

Maximum value for OPRN

•OPRN-MIN

Minimum value for OPRN

•OPT-AVG

Average Transmit Power in 1/10 uW

•OPT-MAX

Maximum Transmit Power in 1/10 uW

•OPT-MIN

Minimum Transmit Power in 1/10uW

•OPTN

Normalized value for Optical Power Transmitted for the OC3-8 card

•OPTN-MAX

Maximum value for OPTN

•OPTN-MIN

Minimum value for OPTN

•OPWR-AVG

Optical Power—Average Interval Value in 1/10th of dBm

•OPWR-MAX

Optical Power—Maximum Interval Value in 1/10th of dBm

•OPWR-MIN

Optical Power—Minimum Interval Value in 1/10th of dBm

•PPJC-PDET

PPJC-PDET:Positive Pointer Justification

•PPJC-PGEN

PPJC-PGEN:Positive Pointer Justification

•PSC

Protection Switching Count

•PSC-R

Protection Switching Count—Ring

•PSC-S

Protection Switching Count—Span

•PSC-W

Protection Switching Count—Working

•PSD

Protection Switching Duration

•PSD-R

Protection Switching Duration—Ring

•PSD-S

Protection Switching Duration—Span

•PSD-W

Protection Switching Duration—Working

•SASCPP

Severely Errored Framing/AIS Second—CP-Bit Path

•SASP

Severely Errored Framing/AIS Seconds Path

•SEFS

Severely Errored Framing Seconds

•SEFSP

Severely Errored Framing Seconds—Path (DS3XM-12 DS1 PM count)

•SESCPP

Severely Errored Second—CP-Bit Path

•SESL

Severely Errored Second—Line

•SESNPFE

Severely Errored Second - Network Path (DS3XM-12 DS1 PM count)

•SESP

Severely Errored Second—Path

•SES-PM

OTN—Severely Errored Second—Path

•SESR-PM

OTN—Severely Errored Second Ratio—Path Monitor Point expressed as 1/10th of a percentage

•SESR-SM

OTN—Severely Errored Second Ratio—Section Monitor Point expressed as 1/10th of a percentage

•SESS

Severely Errored Second—Section

•SES-SM

OTN—Severely Errored Second—Section Monitor Point

•SESV

Severely Errored Second—VT Path

•UASCPP

Unavailable Second—CP-Bit Path

•UASL

Unavailable Second—Line

•UASNPFE

Unavailable Second - Network Path (DS3XM-12 DS1 PM count)

•UASP

Unavailable Second—Path

•UAS-PM

OTN—Unavailable Second—Path Monitor Point

•UAS-SM

OTN—Unavailable Second—Section Monitor Point

•UASV

Unavailable Second—VT Path

•UNC-WORDS

FEC—Uncorrectable Words

•VPC

Valid Packet Count

LOCN

Location associated with a particular command in reference to the entity identified by the AID

Parameter type is LOCATION—the location where the action is to take place

•FEND

Action occurs on the Far End of the facility

•NEND

Action occurs on the Near End of the facility

DIRN

Direction relative to the entity identified by the AID. Defaults to ALL which means that the command initializes all of the registers irrespective of the PM direction

Parameter type is DIRECTION—transmit and receive directions

•BTH

Both transmit and receive directions

•RCV

Receive direction only

•TRMT

Transmit direction only

TMPER

Accumulation time period for performance counters. A null value defaults to 15-MIN. Defaults to 15-MIN

Parameter type is TMPER—accumulation time period for the performance management center

•1-DAY

Performance parameter accumulation interval length; every 24-hours. For SONET PM data only one day of history data is available. For RMON managed PM data seven days of history data are available.

•1-HR

Performance parameter accumulation interval length; every 1 hour. This is only applicable to RMON managed PM data. There are 24 hours of history data available.

•1-MIN

Performance parameter accumulation interval length; every 1 minute. This is only applicable to RMON managed PM data. There are 60 minutes of history available.

•15-MIN

Performance parameter accumulation interval length; every 15 minutes. There are 32 15-MIN buckets of history data available for this accumulation interval length.

•RAW-DATA

Performance parameter accumulation interval length; starting from the last time the counters were cleared. This is only applicable to RMON managed PMs.


15.2  INIT-SYS

Initialize System

Usage Guidelines

Cisco ONS 15454, ONS 15327, ONS 15600, ONS 15310-CL

This command initializes the specified card and its associated subsystems.


Note•The SLOT-ALL AID and the list AID are not allowed in this command.

•Only one level of restart is supported in this command for the ONS 15454 and the ONS 15327.

•It is important that the standby TCC2/TCC2P should be up and running fully standby before this command is sent on the active TCC2/TCC2P for a period of time. During this time, the system is vulnerable to traffic outages caused by timing disruptions or other causes.

•The ONS 15310-CL supports the RESTART parameters for the 15310-CL-CTX, CE-100T-8 and ML-100T-8 cards only.

•The ONS 15600 does not support soft resets on pluggable IO modules (PIMs).

•If a card is hard reset it has to be in one of the following states: OOS-MA, MT; OOS-MA, DSBLD; OOS-AUMA, MT; OOS-AUMA, DSBLD.


Category

System

Security

Maintenance

Related Commands

ACT-USER

ALW-MSG-ALL

ALW-MSG-DBCHG

ALW-MSG-SECU

COPY-RFILE

DLT-TRAPTABLE

ED-DAT

ED-NE-GEN

ED-NE-PATH

ED-NE-SYNCN

ED-TRAPTABLE

ENT-TRAPTABLE

INH-MSG-ALL

INH-MSG-DBCHG

INH-MSG-SECU

REPT EVT FXFR

RTRV-HDR

RTRV-INV

RTRV-MAP-NETWORK

RTRV-NE-APC

RTRV-NE-GEN

RTRV-NE-IPMAP

RTRV-NE-PATH

RTRV-NE-SYNCN

RTRV-NE-WDMANS

RTRV-TOD

RTRV-TRAPTABLE

SET-TOD


Input Format

INIT-SYS:[<TID>]:<AID>:<CTAG>::<PH>[,<CMDMODE>];

Input Examples

INIT-SYS:HOTWATER:SLOT-8:201::1,FRCD;

Input Parameters

Table 15-2 INIT-SYS Input Parameters 

Parameter and Values
Description

AID

Access identifier from the "EQPT" section

PH

The phase. 1=soft reset; 2=hard reset. PH is a required parameter for the ONS 15600 and ONS 15310-CL. PH is not supported on the ONS 15327. PH is supported on the CE-100T-8 on the ONS 15454. Integer

CMDMDE

Command Mode. Allows the user to override safety checks. CMDMDE is optional for the ONS 15600 and defaults to NORM. CMDMDE is not supported on the ONS 15454, ONS 15327, ONS 15310-CL

Parameter type is CMDMDE—forces the system to execute a given command regardless of any standing conditions. Normal mode is the default behavior for all commands, but you can specify FRCD to force the system to override a state where the command would normally be denied

•FRCD

Force the system to override a state where the command would normally be denied

•NORM

Execute the command normally. Do not override any conditions that could make the command fail



hometocprevnextglossaryfeedbacksearchhelp

Posted: Mon Sep 3 11:18:54 PDT 2007
All contents are Copyright © 1992--2007 Cisco Systems, Inc. All rights reserved.
Important Notices and Privacy Statement.