cc/td/doc/product/ong/15400/r60docs
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table Of Contents

EX Commands

13.1  EX-SW-<OCN_BLSR>


EX Commands


This chapter provides EX (exercise) commands for the Cisco ONS 15454, ONS 15327, ONS 15600 and ONS 15310-CL.

13.1  EX-SW-<OCN_BLSR>

Exercise Protection Switch (OC12, OC48, OC192)

See Table 27-1 for supported modifiers by platform.

Usage Guidelines

Cisco ONS 15454, ONS 15327, ONS 15600, ONS 15310-CL

This command exercises the algorithm for switching from a working facility to a protection facility without actually performing a switch. It is assumed that the facility being exercised is the working unit. The exercise switching success or failure result will be indicated by an automatic alarm.

Exercise switch for the SONET protection line is not supported in this release. If sending this command to the protection unit, an error message will be returned. In addition to all normal INPUT, EQUIPAGE, PRIVILEGE error codes, the following error codes are also included in this command:

SNVS (Status, Not in Valid State)

SROF (Status, Requested Operation Failed)

SSRD (Status, Switch Request Denied)


NoteIf you send the EX-SW-<OCN_BLSR> command to both east and west sides/spans of a two-fiber or four-fiber ring within a short time period (less than 30-45 seconds) the system will only execute one (WEST) side EXER-RING query, and preempt the other (EAST) side query. There will be no event messages reported for the preempted side, and it will be in APS-CLEAR switching state.

Examples of sending the EX-SW-<OCN_BLSR> command to both east and west sides/spans of a two-fiber or four-fiber ring within a short time period (less than 30-45 seconds) are: (a) A single command with both side/span AIDs (in the list AID format) of the same two-fiber or four-fiber ring or (b) Separate queries (through TL1 or CTC, or TL1 and CTC) on both sides/spans of the same two-fiber or four-fiber ring

DIRN is an optional parameter. A NULL value of this parameter defaults to BTH for a two-fiber or four-fiber BLSR protection group.

DIRN follows these rules:

TRMT will always fail for any kind of protection groups

For two-fiber and four-fiber BLSR protection groups both the RCV and TRMT direction will fail.

Only BTH is a valid parameter. EX-SW-<OCN_TYPE> can be operated only on BLSR protection groups.


Category

BLSR

Security

Maintenance

Related Commands

ALW-SWDX-EQPT

ALW-SWTOPROTN-EQPT

ALW-SWTOWKG-EQPT

CHG-ACCMD-<MOD_TACC>

CONN-TACC-<MOD_TACC>

DISC-TACC

DLT-<MOD_RING>

DLT-FFP-<MOD2DWDMPAYLOAD>

DLT-FFP-<OCN_TYPE>

ED-<MOD_RING>

ED-FFP-<MOD2DWDMPAYLOAD>

ED-FFP-<OCN_TYPE>

ED-FFP-OCH

ENT-<MOD_RING>

ENT-FFP-<MOD2DWDMPAYLOAD>

ENT-FFP-<OCN_TYPE>

INH-SWDX-EQPT

INH-SWTOPROTN-EQPT

INH-SWTOWKG-EQPT

OPR-LPBK-<MOD2>

OPR-PROTNSW-<OCN_TYPE>

REPT SW

RLS-LPBK-<MOD2>

RLS-PROTNSW-<OCN_TYPE>

RTRV-<MOD_RING>

RTRV-FFP-<MOD2DWDMPAYLOAD>

RTRV-FFP-<OCN_TYPE>

RTRV-FFP-OCH

RTRV-PROTNSW-<OCN_TYPE>

RTRV-PTHTRC-<PATH>

RTRV-TACC

RTRV-TRC-<OCN_BLSR>

SW-DX-EQPT

SW-TOPROTN-EQPT

SW-TOWKG-EQPT


Input Format

EX-SW-<OCN_BLSR>:[<TID>]:<AID>:<CTAG>::,[<SWITCHTYPE>],[<DIRECTION>];

Input Example

EX-SW-OC48:CISCO:FAC-12-1:123::,SPAN,BTH;

Input Parameters

Table 13-1 EX-SW-<OCN_BLSR> Input Parameters 

Parameter and Values
Description

AID

Access identifier from the "FACILITY" section. Identifies the facility in the NE to which the switch request is directed

SWITCHTYPE

Switch type. Must not be null

Parameter type is SWITCH_TYPE—BLSR switch type. MANWKSWBK, MANWKSWPR, FRCDWKSWBK, FRCDWKSWPR, LOCKOUTOFPR, and LOCKOUTOFWK are retrieve-only values for RTRV-PROTNSW-OCn commands. They are not applicable for the OPR-PROTNSW-OCn commands. RING and SPAN are the only allowed values for BLSR protection

FRCDWKSWBK

Working unit is forced to switch back to working

FRCDWKSWPR

Working unit is forced to switch to the protection unit

LOCKOUTOFPR

Lockout of protection

LOCKOUTOFWK

Lockout of working

MANWKSWBK

Manual switch of working unit back to working

MANWKSWPR

Manual switch of working unit back to the protection unit

RING

BLSR ring switch type

SPAN

BLSR span switch type

DIRECTION

Direction. A null value defaults to RCV

Parameter type is DIRECTION—transmit and receive direction

BTH

Both transmit and receive directions

RCV

Receive direction only

TRMT

Transmit direction only



hometocprevnextglossaryfeedbacksearchhelp