Table Of Contents
EX Commands
This chapter provides EX (exercise) commands for the Cisco ONS 15454, ONS 15327, ONS 15600 and ONS 15310-CL.
13.1 EX-SW-<OCN_BLSR>
Exercise Protection Switch (OC12, OC48, OC192)
See Table 27-1 for supported modifiers by platform.
Usage Guidelines
Cisco ONS 15454, ONS 15327, ONS 15600, ONS 15310-CL
This command exercises the algorithm for switching from a working facility to a protection facility without actually performing a switch. It is assumed that the facility being exercised is the working unit. The exercise switching success or failure result will be indicated by an automatic alarm.
Exercise switch for the SONET protection line is not supported in this release. If sending this command to the protection unit, an error message will be returned. In addition to all normal INPUT, EQUIPAGE, PRIVILEGE error codes, the following error codes are also included in this command:
SNVS (Status, Not in Valid State)
SROF (Status, Requested Operation Failed)
SSRD (Status, Switch Request Denied)
Note•If you send the EX-SW-<OCN_BLSR> command to both east and west sides/spans of a two-fiber or four-fiber ring within a short time period (less than 30-45 seconds) the system will only execute one (WEST) side EXER-RING query, and preempt the other (EAST) side query. There will be no event messages reported for the preempted side, and it will be in APS-CLEAR switching state.
Examples of sending the EX-SW-<OCN_BLSR> command to both east and west sides/spans of a two-fiber or four-fiber ring within a short time period (less than 30-45 seconds) are: (a) A single command with both side/span AIDs (in the list AID format) of the same two-fiber or four-fiber ring or (b) Separate queries (through TL1 or CTC, or TL1 and CTC) on both sides/spans of the same two-fiber or four-fiber ring
•DIRN is an optional parameter. A NULL value of this parameter defaults to BTH for a two-fiber or four-fiber BLSR protection group.
DIRN follows these rules:
–TRMT will always fail for any kind of protection groups
–For two-fiber and four-fiber BLSR protection groups both the RCV and TRMT direction will fail.
–Only BTH is a valid parameter. EX-SW-<OCN_TYPE> can be operated only on BLSR protection groups.
CategoryBLSR
SecurityMaintenance
Related Commands
Input FormatEX-SW-<OCN_BLSR>:[<TID>]:<AID>:<CTAG>::,[<SWITCHTYPE>],[<DIRECTION>];
Input ExampleEX-SW-OC48:CISCO:FAC-12-1:123::,SPAN,BTH;
Input Parameters
Table 13-1 EX-SW-<OCN_BLSR> Input Parameters
Parameter and Values DescriptionAID
Access identifier from the "FACILITY" section. Identifies the facility in the NE to which the switch request is directed
SWITCHTYPE
Switch type. Must not be null
Parameter type is SWITCH_TYPE—BLSR switch type. MANWKSWBK, MANWKSWPR, FRCDWKSWBK, FRCDWKSWPR, LOCKOUTOFPR, and LOCKOUTOFWK are retrieve-only values for RTRV-PROTNSW-OCn commands. They are not applicable for the OPR-PROTNSW-OCn commands. RING and SPAN are the only allowed values for BLSR protection
•FRCDWKSWBK
Working unit is forced to switch back to working
•FRCDWKSWPR
Working unit is forced to switch to the protection unit
•LOCKOUTOFPR
Lockout of protection
•LOCKOUTOFWK
Lockout of working
•MANWKSWBK
Manual switch of working unit back to working
•MANWKSWPR
Manual switch of working unit back to the protection unit
•RING
BLSR ring switch type
•SPAN
BLSR span switch type
DIRECTION
Direction. A null value defaults to RCV
Parameter type is DIRECTION—transmit and receive direction
•BTH
Both transmit and receive directions
•RCV
Receive direction only
•TRMT
Transmit direction only
Posted: Mon Sep 3 11:17:59 PDT 2007
All contents are Copyright © 1992--2007 Cisco Systems, Inc. All rights reserved.
Important Notices and Privacy Statement.