cc/td/doc/product/ong/15400/r60docs
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table Of Contents

ED Commands

11.1  ED-<GIGE_TYPE>

11.2  ED-<MOD1FCPAYLOAD>

11.3  ED-<MOD1FICONPAYLOAD>

11.4  ED-<MOD2DWDMPAYLOAD>

11.5  ED-<MOD_PATH>

11.6  ED-<MOD_RING>

11.7  ED-<OCN_TYPE>

11.8  ED-ALS

11.9  ED-APC

11.10  ED-BITS

11.11  ED-BULKROLL-<OCN_TYPE>

11.12  ED-CMD-SECU

11.13  ED-CRS-<PATH>

11.14  ED-DAT

11.15  ED-DS1

11.16  ED-EC1

11.17  ED-EQPT

11.18  ED-FAC

11.19  ED-FFP-<MOD2DWDMPAYLOAD>

11.20  ED-FFP-<OCN_TYPE>

11.21  ED-FFP-OCH

11.22  ED-FSTE

11.23  ED-G1000

11.24  ED-GFP

11.25  ED-HDLC

11.26  ED-LNK-<MOD2O>

11.27  ED-LNKTERM

11.28  ED-NE-GEN

11.29  ED-NE-PATH

11.30  ED-NE-SYNCN

11.31  ED-OCH

11.32  ED-OMS

11.33  ED-OSC

11.34  ED-OTS

11.35  ED-PID

11.36  ED-POS

11.37  ED-PROTOCOL

11.38  ED-ROLL-<MOD_PATH>

11.39  ED-SLV-WDMANS

11.40  ED-SYNCN

11.41  ED-T1

11.42  ED-T3

11.43  ED-TRAPTABLE

11.44  ED-TRC-OCH

11.45  ED-USER-SECU

11.46  ED-VCG

11.47  ED-WDMANS

11.48  ED-WLEN


ED Commands



Note The terms "Unidirectional Path Switched Ring" and "UPSR" may appear in Cisco literature. These terms do not refer to using Cisco ONS 15xxx products in a unidirectional path switched ring configuration. Rather, these terms, as well as "Path Protected Mesh Network" and "PPMN," refer generally to Cisco's path protection feature, which may be used in any topological network configuration. Cisco does not recommend using its path protection feature in any particular topological network configuration.


This chapter provides ED (edit) commands for the Cisco ONS 15454, ONS 15327, ONS 15600 and ONS 15310-CL.

11.1  ED-<GIGE_TYPE>

Edit (10GIGE, GIGE)

Usage Guidelines

Cisco ONS 15454, ONS 15600

This command edits Ethernet facility attributes.

See Table 27-1 for supported modifiers by platform.

Category

Ports

Security

Provisioning

Related Commands

DLT-<MOD1PAYLOAD>

DLT-FFP-<MOD2DWDMPAYLOAD>

DLT-FFP-<OCN_TYPE>

ED-<MOD1FCPAYLOAD>

ED-<MOD1FICONPAYLOAD>

ED-<MOD2DWDMPAYLOAD>

ED-<OCN_TYPE>

ED-ALS

ED-DS1

ED-EC1

ED-FFP-<MOD2DWDMPAYLOAD>

ED-FFP-<OCN_TYPE>

ED-FSTE

ED-G1000

ED-GFP

ED-HDLC

ED-POS

ED-T1

ED-T3

ED-TRC-<MOD2DWDMPAYLOAD>

ED-TRC-<OCN_TYPE>

ENT-<MOD1PAYLOAD>

ENT-FFP-<MOD2DWDMPAYLOAD>

ENT-FFP-<OCN_TYPE>

INIT-REG-<MOD2>

OPR-ALS

OPR-LPBK-<MOD2>

OPR-PROTNSW-<MOD2DWDMPAYLOAD>

OPR-PROTNSW-<OCN_TYPE>

REPT PM <MOD2>

RLS-LPBK-<MOD2>

RLS-PROTNSW-<MOD2DWDMPAYLOAD>

RLS-PROTNSW-<OCN_TYPE>

RMV-<MOD2>

RST-<MOD2>

RTRV-<MOD1FCPAYLOAD>

RTRV-<MOD1FICONPAYLOAD>

RTRV-<MOD2DWDMPAYLOAD>

RTRV-<OCN_TYPE>

RTRV-10GIGE

RTRV-ALMTH-<MOD2>

RTRV-ALS

RTRV-DS1

RTRV-EC1

RTRV-FAC

RTRV-FFP-<MOD2DWDMPAYLOAD>

RTRV-FFP-<OCN_TYPE>

RTRV-FSTE

RTRV-G1000

RTRV-GFP

RTRV-GIGE

RTRV-HDLC

RTRV-PM-<MOD2>

RTRV-PMSCHED-<MOD2>

RTRV-POS

RTRV-PROTNSW-<MOD2DWDMPAYLOAD>

RTRV-PROTNSW-<OCN_TYPE>

RTRV-T1

RTRV-T3

RTRV-TH-<MOD2>

RTRV-TRC-<MOD2DWDMPAYLOAD>

RTRV-TRC-<OCN_TYPE>

SCHED-PMREPT-<MOD2>

SET-ALMTH-<MOD2>

SET-TH-<MOD2>


Input Format

ED-<GIGE_TYPE>:[<TID>]:<AID>:<CTAG>:::[NAME=<NAME>],[MACADDR=<MACADDR>],
[CMDMDE=<CMDMDE>],[FREQ=<FREQ>],[LOSSB=<LOSSB>]:[<PST>[,<SST>]];

Input Example

ED-GIGE:CISCO:FAC-1-1:123:::NAME="GIGE PORT",
MACADDR=00-0E-AA-BB-CC-FF,CMDMDE=CMDMDE,FREQ=1550,LOSSB=SX:IS,AINS;

Input Parameters

Table 11-1 ED-<GIGE_TYPE> Input Parameters 

Parameter and Values
Description

AID

Access identifier from the "FACILITY" section

NAME

Port name. String. Defaults to NULL. Maximum length is 32 characters

MACADDR

String. Defaults to NULL. Maximum length is 18 characters

CMDMDE

Command execution mode. NORM for normal (default) and FRCD for forced. FRCD will override any safeguards that normally reject a request to delete an in service resource

Parameter type is CMDMDE—forces the system to execute a given command regardless of any standing conditions. Normal mode is the default behavior for all commands but you can specify FRCD to force the system to override a state where the command would normally be denied

FRCD

Force the system to override a state where the command would normally be denied

NORM

Execute the command normally. Do not override any conditions that might make the command fail

FREQ

Parameter type is OPTICAL-WLEN—optical wavelength

1530.33

Wavelength 1

1531.12

Wavelength 2

1531.90

Wavelength 3

1532.68

Wavelength 4

1534.25

Wavelength 5

1535.04

Wavelength 6

1535.82

Wavelength 7

1536.61

Wavelength 8

1538.19

Wavelength 9

1538.98

Wavelength 10

1539.77

Wavelength 11

1540.56

Wavelength 12

1542.14

Wavelength 13

1542.94

Wavelength 14

1543.73

Wavelength 15

1544.53

Wavelength 16

1546.12

Wavelength 17

1546.92

Wavelength 18

1547.72

Wavelength 19

1548.51

Wavelength 20

1550.12

Wavelength 21

1550.92

Wavelength 22

1551.72

Wavelength 23

1552.52

Wavelength 24

1554.13

Wavelength 25

1554.94

Wavelength 26

1555.75

Wavelength 27

1556.55

Wavelength 28

1558.17

Wavelength 29

1558.98

Wavelength 30

1559.79

Wavelength 31

1560.61

Wavelength 32

USE-TWL1

Use Tunable Wavelength 1

LOSSB

Parameter type is REACH—reach values

AUTOPROV

Autoprovisioning

CX

Reach CX

DX

Reach DX

HX

Reach HX

I1

Reach I1

IR-1

Reach IR-1

IR-2

Reach IR-2

L1

Reach L1

L2

Reach L2

L3

Reach L3

LR-1

Reach LR-1

LR-2

Reach LR-2

LR-3

Reach LR-3

LX

Reach LX

S1

Reach S1

S2

Reach S2

SR

Reach SR

SR-1

Reach SR-1

SX

Reach SX

T

Reach T

VX

Reach VX

ZX

Reach ZX

PST

Primary state

Parameter type is PST—indicates the current overall service condition of an entity

IS

In service

OOS

Out of service

SST

Secondary state

Parameter type is SST—provides additional information pertaining to PST and PSTQ

AINS

Automatic in service

DSBLD

Disabled

LPBK

Loopback

MEA

Mismatch of equipment and attributes

MT

Maintenance mode

OOG

Out of group

SWDL

Software downloading

UAS

Unassigned

UEQ

Unequipped


11.2  ED-<MOD1FCPAYLOAD>

Edit (1GFC, 2GFC)

Usage Guidelines

Cisco ONS 15454

See Table 27-1 for supported modifiers by platform.

This command edits the attributes related to the Fibre Channel (FC) facility. The state IS,AINS is not supported on the FC port.


NoteThe port parameters: VIZ, LINKRCVRY, DISTEXTN, AUTODETECTION, LINKCREDITS and MFS can be edited only if the port state is OOS,MT or OOS,DSBLD.

The port parameters: AUTODETECTION, LINKCREDITS and MFS can be edited only if distance extension is enabled (set to B2B).

When 1GFICON and 2GFICON payloads are provisioned, distance extension=B2B is the default and only valid setting. Setting distance extension (using the ED-nGFICON command) to any other setting will be denied with an error message, for example, Provisioning Rules Failed.


Category

Ports

Security

Provisioning

Related Commands

DLT-<MOD1PAYLOAD>

DLT-FFP-<MOD2DWDMPAYLOAD>

DLT-FFP-<OCN_TYPE>

ED-<GIGE_TYPE>

ED-<MOD1FICONPAYLOAD>

ED-<MOD2DWDMPAYLOAD>

ED-<OCN_TYPE>

ED-ALS

ED-DS1

ED-EC1

ED-FFP-<MOD2DWDMPAYLOAD>

ED-FFP-<OCN_TYPE>

ED-FSTE

ED-G1000

ED-GFP

ED-HDLC

ED-POS

ED-T1

ED-T3

ED-TRC-<MOD2DWDMPAYLOAD>

ED-TRC-<OCN_TYPE>

ENT-<MOD1PAYLOAD>

ENT-FFP-<MOD2DWDMPAYLOAD>

ENT-FFP-<OCN_TYPE>

INIT-REG-<MOD2>

OPR-ALS

OPR-LPBK-<MOD2>

OPR-PROTNSW-<MOD2DWDMPAYLOAD>

OPR-PROTNSW-<OCN_TYPE>

REPT PM <MOD2>

RLS-LPBK-<MOD2>

RLS-PROTNSW-<MOD2DWDMPAYLOAD>

RLS-PROTNSW-<OCN_TYPE>

RMV-<MOD2>

RST-<MOD2>

RTRV-<MOD1FCPAYLOAD>

RTRV-<MOD1FICONPAYLOAD>

RTRV-<MOD2DWDMPAYLOAD>

RTRV-<OCN_TYPE>

RTRV-10GIGE

RTRV-ALMTH-<MOD2>

RTRV-ALS

RTRV-DS1

RTRV-EC1

RTRV-FAC

RTRV-FFP-<MOD2DWDMPAYLOAD>

RTRV-FFP-<OCN_TYPE>

RTRV-FSTE

RTRV-G1000

RTRV-GFP

RTRV-GIGE

RTRV-HDLC

RTRV-PM-<MOD2>

RTRV-PMSCHED-<MOD2>

RTRV-POS

RTRV-PROTNSW-<MOD2DWDMPAYLOAD>

RTRV-PROTNSW-<OCN_TYPE>

RTRV-T1

RTRV-T3

RTRV-TH-<MOD2>

RTRV-TRC-<MOD2DWDMPAYLOAD>

RTRV-TRC-<OCN_TYPE>

SCHED-PMREPT-<MOD2>

SET-ALMTH-<MOD2>

SET-TH-<MOD2>


Input Format

ED-<MOD1FCPAYLOAD>:[<TID>]:<AID>:<CTAG>:::[LINKRCVRY=<LINKRCVRY>],
[DISTEXTN=<DISTEXTN>],[AUTODETECTION=<AUTODETECTION>],
[LINKCREDITS=<LINKCREDITS>],[MFS=<MFS>],[NAME=<NAME>],
[CMDMDE=<CMDMDE>],[SOAK=<SOAK>],[FREQ=<FREQ>],
[LOSSB=<LOSSB>]:[<PST>[,[<SST>]];

Input Example

ED-1GFC:CISCO:FAC-6-1:1:::LINKRCVRY=Y,DISTEXTN=NONE,AUTODETECTION=Y,
LINKCREDITS=10,MFS=2148,NAME="FC PORT",CMDMDE=CMDMDE,SOAK=32,
FREQ=1550,LOSSB=LR-1:OOS,MT;

Input Parameters

Table 11-2 ED-<MOD1FCPAYLOAD> Input Parameters 

Parameter and Values
Description

AID

Access identifier from the "FACILITY" section

LINKRCVRY

Link recovery

Parameter type is ON_OFF—disable or enable an attribute

N

Disable an attribute

Y

Enable an attribute

DISTEXTN

Distance extension. It can be set to Buffer-to-Buffer (B2B) Credit Management state or None.

Note B2B and link recovery are mutually exclusive. You cannot turn on both B2B and link recovery at the same time

Parameter type is DISTANCE_EXTENSION—distance extension

B2B

Buffer to buffer flow control

NONE

No distance extension

AUTODETECTION

Autodetection. Turns autodetection on or off

Parameter type is ON_OFF—disable or enable an attribute

N

Disable an attribute

Y

Enable an attribute

LINKCREDITS

Number of link credits. If autodetection is set to off the value of the link credits will be used to configure the hardware. Integer

MFS

Maximum frame size. Integer

NAME

String

CMDMDE

Command execution mode, forced or normal. FRCD deletes all the VCG members and member cross-connects of a VCG

Parameter type is CMDMDE—forces the system to execute a given command regardless of any standing conditions. Normal mode is the default behavior for all commands but you can specify FRCD to force the system to override a state where the command would normally be denied

FRCD

Force the system to override a state where the command would normally be denied

NORM

Execute the command normally. Do not override any conditions that might make the command fail

SOAK

OOS-AINS to IS transition soak time as measured in 15-minute intervals. A value of 4 equals a soak time of 1 hour. The allowable range is 0 to 192 intervals (maximum of 48 hours). Integer

FREQ

Parameter type is OPTICAL-WLEN—optical wavelength

1530.33

Wavelength 1

1531.12

Wavelength 2

1531.90

Wavelength 3

1532.68

Wavelength 4

1534.25

Wavelength 5

1535.04

Wavelength 6

1535.82

Wavelength 7

1536.61

Wavelength 8

1538.19

Wavelength 9

1538.98

Wavelength 10

1539.77

Wavelength 11

1540.56

Wavelength 12

1542.14

Wavelength 13

1542.94

Wavelength 14

1543.73

Wavelength 15

1544.53

Wavelength 16

1546.12

Wavelength 17

1546.92

Wavelength 18

1547.72

Wavelength 19

1548.51

Wavelength 20

1550.12

Wavelength 21

1550.92

Wavelength 22

1551.72

Wavelength 23

1552.52

Wavelength 24

1554.13

Wavelength 25

1554.94

Wavelength 26

1555.75

Wavelength 27

1556.55

Wavelength 28

1558.17

Wavelength 29

1558.98

Wavelength 30

1559.79

Wavelength 31

1560.61

Wavelength 32

USE-TWL1

Use Tunable Wavelength 1

LOSSB

Parameter type is REACH—reach values

AUTOPROV

Autoprovisioning

CX

Reach CX

DX

Reach DX

HX

Reach HX

I1

Reach I1

IR-1

Reach IR-1

IR-2

Reach IR-2

L1

Reach L1

L2

Reach L2

L3

Reach L3

LR-1

Reach LR-1

LR-2

Reach LR-2

LR-3

Reach LR-3

LX

Reach LX

S1

Reach S1

S2

Reach S2

SR

Reach SR

SR-1

Reach SR-1

SX

Reach SX

T

Reach T

VX

Reach VX

ZX

Reach ZX

PST

Primary state

Parameter type is PST—indicates the current overall service condition of an entity

IS

In service

OOS

Out of service

SST

Secondary state

Parameter type is SST—provides additional information pertaining to PST and PSTQ

AINS

Automatic in service

DSBLD

Disabled

LPBK

Loopback

MEA

Mismatch of equipment and attributes

MT

Maintenance mode

OOG

Out of group

SWDL

Software downloading

UAS

Unassigned

UEQ

Unequipped


11.3  ED-<MOD1FICONPAYLOAD>

Edit (1GFICON, 2GFICON)

Usage Guidelines

Cisco ONS 15454

See Table 27-1 for supported modifiers by platform.

This command edits the attributes related with the FICON payload facility. The state IS,AINS is not supported on the FICON port.

Category

Ports

Security

Provisioning

Related Commands

DLT-<MOD1PAYLOAD>

DLT-FFP-<MOD2DWDMPAYLOAD>

DLT-FFP-<OCN_TYPE>

ED-<GIGE_TYPE>

ED-<MOD1FCPAYLOAD>

ED-<MOD2DWDMPAYLOAD>

ED-<OCN_TYPE>

ED-ALS

ED-DS1

ED-EC1

ED-FFP-<MOD2DWDMPAYLOAD>

ED-FFP-<OCN_TYPE>

ED-FSTE

ED-G1000

ED-GFP

ED-HDLC

ED-POS

ED-T1

ED-T3

ED-TRC-<MOD2DWDMPAYLOAD>

ED-TRC-<OCN_TYPE>

ENT-<MOD1PAYLOAD>

ENT-FFP-<MOD2DWDMPAYLOAD>

ENT-FFP-<OCN_TYPE>

INIT-REG-<MOD2>

OPR-ALS

OPR-LPBK-<MOD2>

OPR-PROTNSW-<MOD2DWDMPAYLOAD>

OPR-PROTNSW-<OCN_TYPE>

REPT PM <MOD2>

RLS-LPBK-<MOD2>

RLS-PROTNSW-<MOD2DWDMPAYLOAD>

RLS-PROTNSW-<OCN_TYPE>

RMV-<MOD2>

RST-<MOD2>

RTRV-<MOD1FCPAYLOAD>

RTRV-<MOD1FICONPAYLOAD>

RTRV-<MOD2DWDMPAYLOAD>

RTRV-<OCN_TYPE>

RTRV-10GIGE

RTRV-ALMTH-<MOD2>

RTRV-ALS

RTRV-DS1

RTRV-EC1

RTRV-FAC

RTRV-FFP-<MOD2DWDMPAYLOAD>

RTRV-FFP-<OCN_TYPE>

RTRV-FSTE

RTRV-G1000

RTRV-GFP

RTRV-GIGE

RTRV-HDLC

RTRV-PM-<MOD2>

RTRV-PMSCHED-<MOD2>

RTRV-POS

RTRV-PROTNSW-<MOD2DWDMPAYLOAD>

RTRV-PROTNSW-<OCN_TYPE>

RTRV-T1

RTRV-T3

RTRV-TH-<MOD2>

RTRV-TRC-<MOD2DWDMPAYLOAD>

RTRV-TRC-<OCN_TYPE>

SCHED-PMREPT-<MOD2>

SET-ALMTH-<MOD2>

SET-TH-<MOD2>


Input Format

ED-<MOD1FICONPAYLOAD>:[<TID>]:<AID>:<CTAG>:::[LINKRCVRY=<LINKRCVRY>],
[DISTEXTN=<DISTEXTN>],[AUTODETECTION=<AUTODETECTION>],
[LINKCREDITS=<LINKCREDITS>],[MFS=<MFS>],[NAME=<NAME>],
[CMDMDE=<CMDMDE>],[SOAK=<SOAK>],[FREQ=<FREQ>],
[LOSSB=<LOSSB>]:[<PST>[,<SST>]];

Input Example

ED-1GFICON:CISCO:FAC-6-1:1:::LINKRCVRY=Y,DISTEXTN=NONE,AUTODETECTION=Y,
LINKCREDITS=10,MFS=2148,NAME="FC PORT",CMDMDE=CMDMDE,SOAK=32,FREQ=1550,
LOSSB=LR-1:OOS,MT;

Input Parameters

Table 11-3 ED-<MOD1FICONPAYLOAD> Input Parameters 

Parameter and Values
Description

AID

Access identifier from the "FACILITY" section

LINKRCVRY

Link recovery

Parameter type is ON_OFF—disable or enable an attribute

N

Disable an attribute

Y

Enable an attribute

DISTEXTN

Distance extension. It can be set to Buffer-to-Buffer (B2B) Credit Management state or None.

Note B2B and link recovery are mutually exclusive. You cannot turn on both B2B and link recovery at the same time

Parameter type is DISTANCE_EXTENSION—distance extension

B2B

Buffer to buffer flow control

NONE

No distance extension

AUTODETECTION

Autodetection. Turns autodetection on or off

Parameter type is ON_OFF—disable or enable an attribute

N

Disable an attribute

Y

Enable an attribute

LINKCREDITS

Number of link credits. If autodetection is set to off the value of the link credits will be used to configure the hardware. Integer

MFS

Maximum frame size. Integer

NAME

String

CMDMDE

Command execution mode, forced or normal. FRCD deletes all the VCG members and member cross-connects of a VCG

Parameter type is CMDMDE—forces the system to execute a given command regardless of any standing conditions. Normal mode is the default behavior for all commands but you can specify FRCD to force the system to override a state where the command would normally be denied

FRCD

Force the system to override a state where the command would normally be denied

NORM

Execute the command normally. Do not override any conditions that might make the command fail

SOAK

OOS-AINS to IS transition soak time as measured in 15-minute intervals. A value of 4 equals a soak time of 1 hour. The allowable range is 0 to 192 intervals (maximum of 48 hours). Integer

FREQ

Parameter type is OPTICAL-WLEN—optical wavelength

1530.33

Wavelength 1

1531.12

Wavelength 2

1531.90

Wavelength 3

1532.68

Wavelength 4

1534.25

Wavelength 5

1535.04

Wavelength 6

1535.82

Wavelength 7

1536.61

Wavelength 8

1538.19

Wavelength 9

1538.98

Wavelength 10

1539.77

Wavelength 11

1540.56

Wavelength 12

1542.14

Wavelength 13

1542.94

Wavelength 14

1543.73

Wavelength 15

1544.53

Wavelength 16

1546.12

Wavelength 17

1546.92

Wavelength 18

1547.72

Wavelength 19

1548.51

Wavelength 20

1550.12

Wavelength 21

1550.92

Wavelength 22

1551.72

Wavelength 23

1552.52

Wavelength 24

1554.13

Wavelength 25

1554.94

Wavelength 26

1555.75

Wavelength 27

1556.55

Wavelength 28

1558.17

Wavelength 29

1558.98

Wavelength 30

1559.79

Wavelength 31

1560.61

Wavelength 32

USE-TWL1

Use Tunable Wavelength 1

LOSSB

Parameter type is REACH—reach values

AUTOPROV

Autoprovisioning

CX

Reach CX

DX

Reach DX

HX

Reach HX

I1

Reach I1

IR-1

Reach IR-1

IR-2

Reach IR-2

L1

Reach L1

L2

Reach L2

L3

Reach L3

LR-1

Reach LR-1

LR-2

Reach LR-2

LR-3

Reach LR-3

LX

Reach LX

S1

Reach S1

S2

Reach S2

SR

Reach SR

SR-1

Reach SR-1

SX

Reach SX

T

Reach T

VX

Reach VX

ZX

Reach ZX

PST

Primary state

Parameter type is PST—indicates the current overall service condition of an entity

IS

In service

OOS

Out of service

SST

Secondary state

Parameter type is SST—provides additional information pertaining to PST and PSTQ

AINS

Automatic in service

DSBLD

Disabled

LPBK

Loopback

MEA

Mismatch of equipment and attributes

MT

Maintenance mode

OOG

Out of group

SWDL

Software downloading

UAS

Unassigned

UEQ

Unequipped


11.4  ED-<MOD2DWDMPAYLOAD>

Edit (10GFC, 10GIGE, 1GFC, 1GFICON, 2GFC, 2GFICON, D1VIDEO, DV6000, ETRCLO, GIGE, HDTV, ISC1, ISC3, PASSTHRU)

Usage Guidelines

Cisco ONS 15454

See Table 27-1 for supported modifiers by platform.

This command edits the operating parameters for a DWDM client facility.

Category

DWDM

Security

Provisioning

Related Commands

DLT-<MOD1PAYLOAD>

DLT-FFP-<MOD2DWDMPAYLOAD>

DLT-FFP-<OCN_TYPE>

ED-<GIGE_TYPE>

ED-<MOD1FCPAYLOAD>

ED-<MOD1FICONPAYLOAD>

ED-<OCN_TYPE>

ED-ALS

ED-DS1

ED-EC1

ED-FFP-<MOD2DWDMPAYLOAD>

ED-FFP-<OCN_TYPE>

ED-FSTE

ED-G1000

ED-GFP

ED-HDLC

ED-POS

ED-T1

ED-T3

ED-TRC-<MOD2DWDMPAYLOAD>

ED-TRC-<OCN_TYPE>

ENT-<MOD1PAYLOAD>

ENT-FFP-<MOD2DWDMPAYLOAD>

ENT-FFP-<OCN_TYPE>

INIT-REG-<MOD2>

OPR-ALS

OPR-LPBK-<MOD2>

OPR-PROTNSW-<MOD2DWDMPAYLOAD>

OPR-PROTNSW-<OCN_TYPE>

REPT PM <MOD2>

RLS-LPBK-<MOD2>

RLS-PROTNSW-<MOD2DWDMPAYLOAD>

RLS-PROTNSW-<OCN_TYPE>

RMV-<MOD2>

RST-<MOD2>

RTRV-<MOD1FCPAYLOAD>

RTRV-<MOD1FICONPAYLOAD>

RTRV-<MOD2DWDMPAYLOAD>

RTRV-<OCN_TYPE>

RTRV-10GIGE

RTRV-ALMTH-<MOD2>

RTRV-ALS

RTRV-DS1

RTRV-EC1

RTRV-FAC

RTRV-FFP-<MOD2DWDMPAYLOAD>

RTRV-FFP-<OCN_TYPE>

RTRV-FSTE

RTRV-G1000

RTRV-GFP

RTRV-GIGE

RTRV-HDLC

RTRV-PM-<MOD2>

RTRV-PMSCHED-<MOD2>

RTRV-POS

RTRV-PROTNSW-<MOD2DWDMPAYLOAD>

RTRV-PROTNSW-<OCN_TYPE>

RTRV-T1

RTRV-T3

RTRV-TH-<MOD2>

RTRV-TRC-<MOD2DWDMPAYLOAD>

RTRV-TRC-<OCN_TYPE>

SCHED-PMREPT-<MOD2>

SET-ALMTH-<MOD2>

SET-TH-<MOD2>


Input Format

ED-<MOD2DWDMPAYLOAD>:[<TID>]:<AID>:<CTAG>:::[NAME=<NAME>],
[CMDMDE=<CMDMDE>],[FREQ=<FREQ>],[LOSSB=<LOSSB>]:[<PST>[,<SST>]];

Input Example

ED-HDTV::FAC-1-1:1:::NAME="PORTNAME",CMDMDE=CMDMDE,FREQ=1550,
LOSSB=LR-1:IS,AINS;

Input Parameters

Table 11-4 ED-<MOD2DWDMPAYLOAD> Input Parameters 

Parameter and Values
Description

AID

Access identifier from the "FACILITY" section

LINKCREDITS

Number of link credits. If autodetection is set to off the value of the link credits will be used to configure the hardware. Integer

NAME

String

CMDMDE

Command execution mode, forced or normal. FRCD deletes all the VCG members and member cross-connects of a VCG

Parameter type is CMDMDE—forces the system to execute a given command regardless of any standing conditions. Normal mode is the default behavior for all commands but you can specify FRCD to force the system to override a state where the command would normally be denied

FRCD

Force the system to override a state where the command would normally be denied

NORM

Execute the command normally. Do not override any conditions that might make the command fail

FREQ

Parameter type is OPTICAL-WLEN—optical wavelength

1530.33

Wavelength 1

1531.12

Wavelength 2

1531.90

Wavelength 3

1532.68

Wavelength 4

1534.25

Wavelength 5

1535.04

Wavelength 6

1535.82

Wavelength 7

1536.61

Wavelength 8

1538.19

Wavelength 9

1538.98

Wavelength 10

1539.77

Wavelength 11

1540.56

Wavelength 12

1542.14

Wavelength 13

1542.94

Wavelength 14

1543.73

Wavelength 15

1544.53

Wavelength 16

1546.12

Wavelength 17

1546.92

Wavelength 18

1547.72

Wavelength 19

1548.51

Wavelength 20

1550.12

Wavelength 21

1550.92

Wavelength 22

1551.72

Wavelength 23

1552.52

Wavelength 24

1554.13

Wavelength 25

1554.94

Wavelength 26

1555.75

Wavelength 27

1556.55

Wavelength 28

1558.17

Wavelength 29

1558.98

Wavelength 30

1559.79

Wavelength 31

1560.61

Wavelength 32

USE-TWL1

Use Tunable Wavelength 1

LOSSB

Parameter type is REACH—reach values

AUTOPROV

Autoprovisioning

CX

Reach CX

DX

Reach DX

HX

Reach HX

I1

Reach I1

IR-1

Reach IR-1

IR-2

Reach IR-2

L1

Reach L1

L2

Reach L2

L3

Reach L3

LR-1

Reach LR-1

LR-2

Reach LR-2

LR-3

Reach LR-3

LX

Reach LX

S1

Reach S1

S2

Reach S2

SR

Reach SR

SR-1

Reach SR-1

SX

Reach SX

T

Reach T

VX

Reach VX

ZX

Reach ZX

PST

Primary state

Parameter type is PST—indicates the current overall service condition of an entity

IS

In service

OOS

Out of service

SST

Secondary state

Parameter type is SST—provides additional information pertaining to PST and PSTQ

AINS

Automatic in service

DSBLD

Disabled

LPBK

Loopback

MEA

Mismatch of equipment and attributes

MT

Maintenance mode

OOG

Out of group

SWDL

Software downloading

UAS

Unassigned

UEQ

Unequipped


11.5  ED-<MOD_PATH>

Edit (STS1, STS12C, STS18C, STS192C, STS24C, STS36C, STS3C, STS48C, STS6C, STS9C, VC12, VC3, VT1, VT2)

This command edits the attributes associated with STS and VT paths.

Usage Guidelines

Cisco ONS 15454, ONS 15327, ONS 15600, ONS 15310-CL

The SFBER, SDBER, RVRTV, and RVTM parameters only apply to path protection at the STS path level and ONS 15310_CL and ONS 15454 VT paths.

SFBER and SDBER also apply to the VT path level on the ONS 15310-CL and ONS 15454 when the ONS 15454 has an XC-VXC-10G card.

SWPDIP does not apply to the VT path level (VT1 and VT2).

The path trace message is a 64 character string including the terminating CR (carriage return) and LF (line feed) that is transported in the J1 byte of the SONET STS Path overhead. Both the EXPTRC and TRC string can be provisioned by user with up to 62 character string.

The EXPTRC indicates the contents of the expected incoming path trace are provisioned by the user. The TRC indicates the contents of the outgoing path trace message. The INCTRC indicates the contents of the incoming path trace message.

The path trace mode has three modes: OFF, MANUAL, and AUTO. The path trace mode defaults to OFF. The MANUAL mode performs the comparison of the received string with the user-entered expected string. The AUTO mode performs the comparison of the present received string with an expected string set to a previously received string. If there is a mismatch, TIM-P alarm is raised. When the path trace is in OFF mode, there is no path trace processing, and all the alarm and state conditions are reset.

The TACC parameter edits an existing single STS or VT and changes it to a test access point. When an editing command on TACC is executed, it assigns the STS or VT for the first 2-way connection and STS+1 as the second 2-way connection. For single FAD test access only a single STS/VT is used for the TAP creation. For more information on TACC, refer to the Cisco ONS SONET TL1 Reference Guide.

J1 is implemented on the DS1/DS1N, DS3E/DS3NE, DS3XM, EC1, OC3, OC12-4, OC48AS and OC192 cards.

DS3/DS3N, OC12, OC48, E100, and E1000 cards do not support path trace.

DS1/DS1N, DS3E/DS3NE, and DS3XM support both TRC and EXPTRC in the ED-STS-PATH command.

EC1, OC3, OC48AS, and OC192 only support EXPTRC in the ED-STS-PATH command.


Note Each TL1 command must be less than or equal to 255 characters. Any command larger than 255 characters must be split into multiple commands. For example, if you use the ED-<MOD_PATH> command to edit the J1 EXPTRC/TRC message, path protection attributes, and TACC attributes and the command exceeds 255 characters the command will not be processed. You must use multiple ED-<MOD_PATH> commands instead.


The following actions will produce error messages:

1. Sending this command to edit SFBER, SDBER, RVRTV or RVTM for the non-path protection STS path.

2. Sending this command to edit the EXPTRC string with the AUTO path trace mode (TRCMODE=AUTO).

3. Sending this command to edit TRC on any card other than DS3(N)E, DS1(N), and DS3XM cards, will return the "TRC-not allowed for monitor paths. Incorrect card type" error message.

4. Sending this command to edit both TACC and any other attribute(s) will return the "Parameters Not compatible" error message.

5. Sending this command to edit TACC on an AID with cross-connections will return the "STS in Use" error message.


NoteTACC creation will be denied on the protect ports/cards for 1:1, 1:N, and 1+1.

The VFAC AID is only valid on slots containing an ML-Series card. TACC is not supported for the ML-Series cards.

After the BLSR switching, provisioning of the J1 trace string or trace mode is not allowed on the protection path.

TACC creation is allowed on PCA for two-fiber and four-fiber BLSR.

TACC is not supported on G1000, MXP_2.5_10G/TXP_MR-10G, ML1000-2 and ML100T-12 cards.

HOLDOFFTIMER is not specific to a path. It is applicable to the path protection selector. If HOLDOFFTIMER is changed on one path associated with the selector, the HOLDOFFTIMER of the other path associated with the same selector is also changed.

The test set physical connection set up through ED-T3/DS1/STS1/VT1 of the DS3XM-12 card is only allowed on the physical front ports (PORTED ports, ports 1-12), which are the monitoring ports.

The monitoring test access ports follow the common rules for the other cards. For example, ED-T3 on port 2 (FAC-6-2) with a TACC number (8), the next port, port 3 (FAC-6-3) is used as the monitoring point also. The RTRV-T3 on both port-2 and port-3 return the same TACC number (8) used to monitor the cross-connection end (A-B). The last port (port 12) is not allowed to set up a physical connection with the test set because there is no next available port to be the monitoring port.

The TACC disconnection (DISC-TACC) and the test access mode change command (CHG-TACC) follow the same requirement as in the step above, but it is applied on the ported ports of the DS3XM-12 card.

The test access connection set-up command (CONN-TACC) has monitored points, which can be portless ports. This command is applied on both ported and portless ports of the DS3XM-12 card.

If the entity has a TACC connection, the entity is not allowed to have ported or portless STS/VT cross-connection (or circuit) provisioning on the DS3XM-12 card.

Test Access is not supported on the ONS 15310-CL.

J2 path trace is not supported on the 15310-CL-CTX card of the ONS 15310-CL, however the CE-100T-8/ML-100T-8 card provisioned in mapper mode does allow J2 provisioning.

The cross-connects on the DS3I card will be STS3C width, but the individual STS 1s within the 3C will be accessible. For editing the path attributes use the ED-STS1 command with the FAC AID.

For TACC creation, use the ED-STS3C command because the TACC path width (like the cross-connect) has to be 3C on the DS3I card. In this case, you are creating a new entity (TAP) on the DS3I card that has to be of 3C width. On the DS3I card the ED0STS command can be used either with STS1 or STS3C depending on the parameter to be modified.

For the selector path on a BLSR, the SWPDIP is not editable and is always in the ON state. If you attempt to edit SWPDIP (for the selector path on a BLSR), an error message will be returned.

You can create an STS1 or VT1.5 single TAP on the DS3XM-12 card's last ported port (12) if the bandwidth is available on that port.

Optical ports do not support MAN and AUTO trace mode because they are not capable of raising AIS on TIM-P. Use AUTO-NO-AIS or MAN-NO-AIS trace mode on optical ports.

Sending the ED-VT1/VT2 commands over ONS 15454 path protection paths to edit SFBER or SDBER (when the ONS 15454 does not have an XC-VXC-10G cross-connect) will return the "Invalid Operation For The XCON" error message.

Sending the ED-VT1/VT2 commands to edit SDBER with 1E-9 will return the "Out Of Range" error message.


Category

Paths

Security

Provisioning

Related Commands

DLT-CRS-<PATH>

DLT-ROLL-<MOD_PATH>

ED-CRS-<PATH>

ED-NE-PATH

ED-ROLL-<MOD_PATH>

ENT-CRS-<PATH>

ENT-ROLL-<MOD_PATH>

OPR-PROTNSW-<PATH>

RLS-PROTNSW-<PATH>

RTRV-<PATH>

RTRV-CRS-<PATH>

RTRV-NE-PATH

RTRV-PROTNSW-<PATH>

RTRV-PTHTRC-<PATH>

RTRV-ROLL-<MOD_PATH>


Input Format

ED-<MOD_PATH>:[<TID>]:<AID>:<CTAG>:::[SFBER=<SFBER>],[SDBER=<SDBER>],
[RVRTV=<RVRTV>],[RVTM=<RVTM>],[SWPDIP=<SWPDIP>],
[HOLDOFFTIMER=<HOLDOFFTIMER>],[EXPTRC=<EXPTRC>],[TRC=<TRC>],
[TRCMODE=<TRCMODE>],[TRCFORMAT=<TRCFORMAT>][TACC=<TACC>],
[TAPTYPE=<TAPTYPE>],[CMDMDE=<CMDMDE>]:[<PST>[,<SST>]];

Input Example

ED-STS3C:FERNDALE:STS-2-1-4:115:::SFBER=1E-3,SDBER=1E-5,RVRTV=Y,RVTM=1.0,
SWPDIP=Y,HOLDOFFTIMER=2000,EXPTRC="EXPTRCSTRING",TRC="TRCSTRING",
TRCMODE=OFF,TRCFORMAT=64-BYTE,TACC=8,TAPTYPE=SINGLE,
CMDMDE=CMDMDE:IS,AINS;

Input Parameters

Table 11-5 ED-<MOD_PATH> Input Parameters 

Parameter and Values
Description

AID

Access identifier from the "CrossConnectId1" section

SFBER

Signal failure threshold. Applies only to path protection. Applies to STS-level paths in SONET (STSn) and to VT-level paths on the ONS 15310-CL with an XC-VXC-10G card. Defaults to 1E-4

Parameter type is SF_BER—the threshold for declaring signal failure on a facility or path

1E-3

SFBER is 1E-3

1E-4

SFBER is 1E-4

1E-5

SFBER is 1E-5

SDBER

Signal degrade threshold. Applies only to path protection. Applies to STS-level paths in SONET (STSn) and to VT-level paths on the ONS 15310-CL with an XC-VXC-10G card. 1E-9 is not allowed for VT-level/LO paths. Defaults to 1E-6

Parameter type is SD_BER—the threshold for declaring signal degrade on a facility or path

1E-5

SDBER is 1E-5

1E-6

SDBER is 1E-6

1E-7

SDBER is 1E-7

1E-8

SDBER is 1E-8

1E-9

SDBER is 1E-9

RVRTV

Revertive mode. The value Y indicates that the protection switching system reverts service to the original line after restoration. The value N indicates that the protection switching system does not revert service to the original line after restoration. RVRTV is applicable only for 1+1 protection switching. Null defaults to N. Only applies to path protection

Parameter type is ON_OFF—disable or enable an attribute

N

Disable an attribute

Y

Enable an attribute

RVTM

Revertive time. RVTM is not allowed to be set while "RVRTV" is N. Only applies to path protection

Parameter type is REVERTIVE_TIME—revertive time

0.5 to 12.0

Revertive time is 0.5 to 12.0 minutes

SWPDIP

On-off switch for path protection payload defect level switching. Applicable only to STS-level paths in SONET (STSn). For the selector path on a BLSR, SWPDIP is not editable and always ON. Defaults to N

Parameter type is ON_OFF—disable or enable an attribute

N

Disable an attribute

Y

Enable an attribute

HOLDOFFTIMER

Hold off timer for path protection DRI. Values must be within 0 and 10000 ms (0 - 10 seconds), with increments of 100 ms. Defaults to "existed value." Integer

EXPTRC

Expected path trace content. Indicates the expected path trace message (J1) contents. EXPTRC is any 64-character ASCII string, including the terminating CR (carriage return) and LF (line feed). Applicable to STS-level paths in SONET (STSn). Applicable to VT-level paths for the DS3XM-12 and CE-100T-8 card on the ONS 15454 and the CE-100T-8 card on ONS 15310-CL. Defaults to 64 null characters. String

TRC

The path trace message to be transmitted. The trace byte (J1) continuously transmits a 64-byte, fixed length ASCII string, one byte at a time. A null value defaults to the NE transmitting 62 null characters (hex 00) and CR and LF. Applicable to STS-level paths in SONET (STSn). Applicable to VT-level paths for the DS3XM-12 and CE-100T-8 card on the ONS 15454 and the CE-100T-8 card on ONS 15310-CL. For ONS 15310-CL, TRC is not provisionable on the EC/OC ports. Defaults to 64 null characters. String

TRCMODE

Path trace mode. Applicable only to STS-level paths in SONET (STSn). Defaults to the OFF mode. ONS 15310-CL EC/OC ports do not support MAN and AUTO, but can be configured as MAN-NO-AIS and AUTO-NO-AIS.

Note The ONS 15600 does not support MAN and AUTO

Parameter type is TRCMODE—trace mode

AUTO

Use the previously received path trace string as the expected string. Not applicable to MXP/TXP cards

AUTO-NO-AIS

Use the previously received path trace string as the expected string and do not turn on AIS and RDI if TIM-P is detected

MAN

Use the provisioned expected string as the expected string

MAN-NO-AIS

Use the provisioned expected string as the expected string and do not turn on AIS and RDI if TIM-P is detected

OFF

Turn off path trace capability. Nothing will be reported

TRCFORMAT

Path trace format. Only 64-byte is supported. Defaults to 64-byte

Parameter type is TRCFORMAT—trace format

64-BYTE

64 byte trace message

TACC

TAP number within a range of 0 to 999. Indicates whether the digroup being provisioned is to be used as a test access digroup. When TACC is 0 (zero), the TAP is deleted. Integer

TAPTYPE

TAP type. Defaults to DUAL

Parameter type is TAPTYPE—test access point type

DUAL

Dual FAD

SINGLE

Single FAD

CMDMDE

Command mode

Parameter type is CMDMDE—forces the system to execute a given command regardless of any standing conditions. Normal mode is the default behavior for all commands but you can specify FRCD to force the system to override a state where the command would normally be denied. Defaults to NORM

FRCD

Force the system to override a state where the command would normally be denied

NORM

Execute the command normally. Do not override any conditions that might make the command fail

PST

Primary state. Defaults to IS

Parameter type is PST—indicates the current overall service condition of an entity

IS

In service

OOS

Out of service

SST

Secondary state. Defaults to AINS

Parameter type is SST—provides additional information pertaining to PST and PSTQ

AINS

Automatic in service

DSBLD

Disabled

LPBK

Loopback

MEA

Mismatch of equipment and attributes

MT

Maintenance mode

OOG

Out of group

SWDL

Software downloading

UAS

Unassigned

UEQ

Unequipped


11.6  ED-<MOD_RING>

Edit Bidirectional Line Switched Ring

Usage Guidelines

Cisco ONS 15454, ONS 15327, ONS 15600

This command edits the BLSR attributes.

ONS 15327 and ONS 15600 do not support four-fiber BLSR.

The RVRTV, RVTM, SRVRTV, SRVTM, NODEID, and RINGID attributes can be edited for the four-fiber BLSR.

The RVRTV, RVTM, NODEID, and RINGID attributes can be edited for the two-Fiber BLSR.

The following actions will produce errors:

If the system fails on getting IOR, a SROF (Get IOR Failed) error message is returned

If the AID is invalid, an IIAC (Invalid AID) error message is returned.

If the BLSR does not exist, a SRQN (BLSR Does Not Exist) error message is returned.

The SROF (Facility Not Provisioned) or (Cannot Access BLSR) error message will be returned for an invalid query.

The SRQN (BLSR Edition Failed) error message is returned for an invalid edition query.

Sending this command to modify SRVRTV or SRVTM on a two-fiber BLSR will return an IDNV (Invalid Data For 2F-BLSR) error message.

Sending this command to modify the nodeid with invalid data will return an IIAC (Invalid NodeId) error message.

Sending this command to change the ringid into invalid data will return an IIAC (Invalid RingId) error message.

Changing the BLSR nodeid with a duplicated ID will return a SROF (Cannot Set NodeId) error message.

Changing the BLSR ringid with a duplicated ID will return a SROF (Cannot Set RingId) error message is returned.


NoteThe ALL AID is invalid for this command.

The list AID format has been supported since R4.6.


Category

BLSR

Security

Provisioning

Related Commands

DLT-<MOD_RING>

ENT-<MOD_RING>

EX-SW-<OCN_BLSR>

RTRV-<MOD_RING>

RTRV-TRC-<OCN_BLSR>


Input Format

ED-<MOD_RING>:[<TID>]:<AID>:<CTAG>:::[RINGID=<RINGID>],[NODEID=<NODEID>],
[RVRTV=<RVRTV>],[RVTM=<RVTM>],[SRVRTV=<SRVRTV>],[SRVTM=<SRVTM>][:];

Input Example

ED-BLSR:PETALUMA:BLSR-43:123:::RINGID=43,NODEID=3,RVRTV=Y,RVTM=2.0,
SRVRTV=Y,SRVTM=5.0;

Input Parameters

Table 11-6 ED-<MOD_RING> Input Parameters 

Parameter and Values
Description

AID

Access identifier from the "AidUnionId1" section. Identifies the BLSR of the NE. ALL or BLSR-ALL AID is not allowed for editing a BLSR

RINGID

The BLSR ID of the NE up to six characters. Valid characters are A-Z and 0-9. String

NODEID

The BLSR node ID of the NE. NODEID ranges from 0 to 31. Integer

RVRTV

Revertive mode. The value Y indicates that the protection switching system reverts service to the original line after restoration. The value N indicates that the protection switching system does not revert service to the original line after restoration. RVRTV is applicable only for 1+1 protection switching. Null defaults to N

Parameter type is ON_OFF—disable or enable an attribute

N

Disable an attribute

Y

Enable an attribute

RVTM

Revertive time. RVTM is not allowed to be set while "RVRTV" is N

Parameter type is REVERTIVE_TIME—revertive time

0.5 to 12.0

Revertive time is 0.5 to 12.0 minutes

SRVRTV

The span revertive mode for four-fiber BLSR only

Parameter type is ON_OFF—disable or enable an attribute

N

Disable an attribute

Y

Enable an attribute

SRVTM

The span revertive time for four-fiber BLSR only. SRVTM is not allowed to be set while SRVRTV is N

Parameter type is REVERTIVE_TIME—revertive time

0.5 to 12.0

Revertive time is 0.5 to 12.0 minutes


11.7  ED-<OCN_TYPE>

Edit (OC3, OC12, OC48, OC192)

Usage Guidelines

Cisco ONS 15454, ONS 15327, ONS 15600, ONS 15310-CL

See Table 27-1 for supported modifiers by platform.

This command edits the attributes (for example, service parameters) and status of an OC-N facility. Allowable states for a facility are Out Of Service (OOS), Out Of Service with Automatic In Service transitioning (OOS-AINS), Out Of Service for Maintenance (OOS-MT), and In Service (IS).

The DCC transmit is bridged to both working and protect in a 1+1 protection scheme. On the receive side, the active one is selected for DCC. The DCC is provisioned on the working port only in a 1+1 protection scheme.

All lines in a 1+1 BLSR must have the same mode. If you change the mode of a line that is in a 1+1 BLSR, an error message will be returned.

UNI-C DCC provisioning notes:

1. The attributes DCC(Y/N) and mode (SONET/SDH) remain the same in the ED/RTRV-OCN commands when the DCC is used for UNI-C, in which case the port attribute UNIC is enables (UNIC=Y).

2. UNI-C DCC termination cannot be deleted by the regular DCC deprovisioning command.

3. If the DCC is created under regular SONET provisioning, and this port is used by UNI-C, the port is converted as a UNI-C DCC automatically.

4. Deprovisioning UNI-C IF/IB IPCC will free up DCC termination automatically.

5. The parameters ALSMODE, ALSCRINT and ALSRCPW are valid only for OC3-8, OC-192, and OC48ELR cards.

6. SDCC/LDCC termination cannot be unprovisioned if a provisionable patchcord termination end point is provisioned on the port.

7. SSM selectable (admssm) and synchronization messaging for output (syncmsgout) are not applicable to ONS 15600.

8. The default values for all optional parameters are NE default values. These values might not be the current value for a parameter. In order to obtain the current value, issue the RTRV-XX command.

9. J0 Support (EXPTRC, TRC, TRCMODE and TRCFORMAT parameters) is supported only by DWDM cards with an OCn payload. J0 is not supported by OC3-8, OC12, OC48, OC192 and other optical cards.

Category

Ports

Security

Provisioning

Related Commands

DLT-FFP-<OCN_TYPE>

ED-DS1

ED-EC1

ED-FFP-<OCN_TYPE>

ED-G1000

ED-GFP

ED-HDLC

ED-T1

ED-T3

ED-TRC-<OCN_TYPE>

ENT-FFP-<OCN_TYPE>

OPR-PROTNSW-<OCN_TYPE>

RLS-PROTNSW-<OCN_TYPE>

RTRV-<OCN_TYPE>

RTRV-DS1

RTRV-EC1

RTRV-FAC

RTRV-FFP-<OCN_TYPE>

RTRV-FSTE

RTRV-G1000

RTRV-GFP

RTRV-GIGE

RTRV-HDLC

RTRV-POS

RTRV-PROTNSW-<OCN_TYPE>

RTRV-T1

RTRV-T3

RTRV-TRC-<OCN_TYPE>


Input Format

ED-<OCN_TYPE>:[<TID>]:<AID>:<CTAG>:::[DCC=<DCC>],[AREA=<AREA>],
[SYNCMSG=<SYNCMSG>],[SENDDUS=<SENDDUS>],[PJMON=<PJMON>],
[SFBER=<SFBER>],[SDBER=<SDBER>],[MODE=<MODE>],[MUX=<MUX>],
[SOAK=<SOAK>],[OSPF=<OSPF>],[LDCC=<LDCC>],[NAME=<NAME>],
[CMDMDE=<CMDMDE>],[EXPTRC=<EXPTRC>],[TRC=<TRC>],[TRCMODE=<TRCMODE>],
[TRCFORMAT=<TRCFORMAT>],[ADMSSM=<ADMSSM>],[SENDDUSFF=<SENDDUSFF>],
[AISONLPBK=<AISONLPBK>],[FREQ=<FREQ>],[LOSSB=<LOSSB>],
[FOREIGNFEND=<FOREIGNFEND>],[FOREIGNIP=<FOREIGNIP>]:[<PST>[,<SST>]];

Input Example

ED-OC48:PENNGROVE:FAC-6-1:114:::DCC=Y,AREA=10.92.63.1,SYNCMSG=N,
SENDDUS=N,PJMON=48,SFBER=1E-4,SDBER=1E-6,MODE=SONET,MUX=E2,SOAK=10,
OSPF=Y,LDCC=N,NAME="OCNPORT",CMDMDE=CMDMDE,EXPTRC="AAA",
TRC="AAA",TRCMODE=MAN,TRCFORMAT=16-BYTE,ADMSSM=PRS,SENDDUSFF=N,
AISONLPBK=AIS_ON_LPBK_ALL,FREQ=1550,LOSSB=LR-1,FOREIGNFEND=N,
FOREIGNIP="IP ADDRESS":IS,AINS;

Input Parameters

Table 11-7 ED-<OCN_TYPE> Input Parameters 

Parameter and Values
Description

AID

Access identifier from the "FACILITY" section

DCC

Indicates whether or not the section DCC is to be used. Identifies the section DCC connection of the port

Parameter type is ON_OFF—disable or enable an attribute

N

Disable an attribute

Y

Enable an attribute

AREA

The area ID and shows up only if the DCC is enabled. String

SYNCMSG

Synchronization status message

Parameter type is EXT_RING—indicates if the ring supports the extended K1/K2/K3 protocol

N

The ring does not support the extended K1/K2/K3 protocol

Y

The ring does support the extended K1/K2/K3 protocol

SENDDUS

The facility will send the DUS (Don't use for Synchronization) value as the sync status message for that facility

Parameter type is ON_OFF—disable or enable an attribute

N

Disable an attribute

Y

Enable an attribute

PJMON

Identifies an OCn port PJMON. Integer

SFBER

Signal failure threshold

Parameter type is SF_BER—the threshold for declaring signal failure on a facility or path

1E-3

SFBER is 1E-3

1E-4

SFBER is 1E-4

1E-5

SFBER is 1E-5

SDBER

Signal degrade threshold

Parameter type is SD_BER—the threshold for declaring signal degrade on a facility or path

1E-5

SDBER is 1E-5

1E-6

SDBER is 1E-6

1E-7

SDBER is 1E-7

1E-8

SDBER is 1E-8

1E-9

SDBER is 1E-9

MODE

OCn port mode

Parameter type is OPTICAL_MODE—the facility's optical mode

SDH

SDH/ETSI optical mode using European/International format

SONET

SONET/ANSI optical mode using the American format

MUX

BLSR extension byte (supported only on the OC48AS card). MUX cannot be configured if:

The card is SONET and the media type is SDHT

The card has an orderwire or UDC connection

This is a protect line and the working line has an orderwire or UDC connection

Parameter type is MUX_TYPE—BLSR extension type

E2

E2 byte (orderwire)

F1

F1 byte (user)

K3

K3 byte

Z2

Z2 byte

SOAK

OOS-AINS to IS transition soak time as measured in 15-minute intervals. A value of 4 equals a soak time of 1 hour. The allowable range is 0 to 192 intervals (maximum of 48 hours). Defaults to 32. Integer

OSFP

The open shortest path first discovery. Defaults to Y

Parameter type is ON_OFF—disable or enable an attribute

N

Disable an attribute

Y

Enable an attribute

LDCC

The line DCC connection on the port. Defaults to N

Parameter type is EXT_RING—indicates if the ring supports the extended K1/K2/K3 protocol

N

The ring does not support the extended K1/K2/K3 protocol

Y

The ring does support the extended K1/K2/K3 protocol

NAME

String. Defaults to NULL. Maximum length is 32 characters

CMDMDE

Command Mode. The FRCD mode of operation is applicable to delete a VCAT member cross-connect from IS-NR or OOS-AU,AINS service state. Defaults to NORM

Parameter type is CMDMDE—forces the system to execute a given command regardless of any standing conditions. Normal mode is the default behavior for all commands but you can specify FRCD to force the system to override a state where the command would normally be denied

FRCD

Force the system to override a state where the command would normally be denied

NORM

Execute the command normally. Do not override any conditions that might make the command fail

EXPTRC

Expected path trace content. Indicates the expected path trace message (J1) contents. EXPTRC is any 64-character ASCII string, including the terminating CR (carriage return) and LF (line feed). Applicable to STS-level paths in SONET (STSn). Applicable to VT-level paths for the DS3XM-12 card on the ONS 15454. Defaults to NULL. String

TRC

The path trace message to be transmitted. The trace byte (J1) continuously transmits a 64-byte, fixed length ASCII string, one byte at a time. A null value defaults to the NE transmitting 62 null characters (hex 00) and CR and LF. Applicable to STS-level paths in SONET (STSn). Applicable to VT-level paths for the DS3XM-12 card on the ONS 15454. String

TRCMODE

Path trace mode. Applicable only to STS-level Paths in SONET (STSn). Defaults to MAN

Parameter type is TRCMODE—trace mode

AUTO

Use the previously received path trace string as the expected string. Not applicable to MXP/TXP cards

AUTO-NO-AIS

Use the previously received path trace string as the expected string and do not turn on AIS and RDI if TIMP is detected

MAN

Use the provisioned expected string as the expected string

MAN-NO-AIS

Use the provisioned expected string as the expected string and do not turn on AIS and RDI if TIMP is detected

OFF

Turn off path trace capability. Nothing will be reported

TRCFORMAT

Trace message size

Parameter type is TRCFORMAT—trace format

1-BYTE

1 byte trace message

16-BYTE

16 byte trace message

64-BYTE

64 byte trace message

ADMSSM

SSM selectable value. It will only appear when SSM is disabled. Defaults to STU

Parameter type is SYNC_CLOCK_REF_QUALITY_LEVEL—clock source quality level for SONET

DUS

Do Not Use For Synchronization

PRS

Primary Reference Source, Stratum 1 Traceable

RES

Reserved For Network Synchronization Use

SMC

SONET Minimum Clock Traceable

ST2

Stratum 2 Traceable

ST3

Stratum 3 Traceable

ST3E

Stratum 3E Traceable

ST4

Stratum 4 Traceable

STU

Synchronized, Traceability Unknown

TNC

Transit Node Clock (2nd Generation Only)

SENDDUSFF

Parameter type is ON_OFF—disable or enable an attribute

N

Disable an attribute

Y

Enable an attribute

AISONLPBK

Parameter type is AIS_ON_LPBK—Indicates if AIS is sent on a loopback

AIS_ONLPBK_FACILITY

AIS is sent on facility loopbacks

AIS_ON_LPBK_ALL

AIS is sent on all loopbacks

AIS_ON_LPBK_OFF

AIS is not sent on loopbacks

AIS_ON_LPBK_TERMINAL

AIS is sent on terminal loopbacks

FREQ

Parameter type is OPTICAL-WLEN—optical wavelength

1530.33

Wavelength 1

1531.12

Wavelength 2

1531.90

Wavelength 3

1532.68

Wavelength 4

1534.25

Wavelength 5

1535.04

Wavelength 6

1535.82

Wavelength 7

1536.61

Wavelength 8

1538.19

Wavelength 9

1538.98

Wavelength 10

1539.77

Wavelength 11

1540.56

Wavelength 12

1542.14

Wavelength 13

1542.94

Wavelength 14

1543.73

Wavelength 15

1544.53

Wavelength 16

1546.12

Wavelength 17

1546.92

Wavelength 18

1547.72

Wavelength 19

1548.51

Wavelength 20

1550.12

Wavelength 21

1550.92

Wavelength 22

1551.72

Wavelength 23

1552.52

Wavelength 24

1554.13

Wavelength 25

1554.94

Wavelength 26

1555.75

Wavelength 27

1556.55

Wavelength 28

1558.17

Wavelength 29

1558.98

Wavelength 30

1559.79

Wavelength 31

1560.61

Wavelength 32

USE-TWL1

Use Tunable Wavelength 1

LOSSB

Parameter type is REACH—reach values

AUTOPROV

Autoprovisioning

CX

Reach CX

DX

Reach DX

HX

Reach HX

I1

Reach I1

IR-1

Reach IR-1

IR-2

Reach IR-2

L1

Reach L1

L2

Reach L2

L3

Reach L3

LR-1

Reach LR-1

LR-2

Reach LR-2

LR-3

Reach LR-3

LX

Reach LX

S1

Reach S1

S2

Reach S2

SR

Reach SR

SR-1

Reach SR-1

SX

Reach SX

T

Reach T

VX

Reach VX

ZX

Reach ZX

FOREIGNFEND

Indicates whether the far-end NE on the DCC is a foreign NE

Parameter type is ON_OFF—disable or enable an attribute

N

Disable an attribute

Y

Enable an attribute

FOREIGNIP

The IP address of the far-end NE on the DCC. Used only if FOREIGNFEND is Y. String

PST

Primary state. Defaults to IS

Parameter type is PST—indicates the current overall service condition of an entity

IS

In service

OOS

Out of service

SST

Secondary state. Defaults to AINS

Parameter type is SST—provides additional information pertaining to PST and PSTQ

AINS

Automatic in service

DSBLD

Disabled

LPBK

Loopback

MEA

Mismatch of equipment and attributes

MT

Maintenance mode

OOG

Out of group

SWDL

Software downloading

UAS

Unassigned

UEQ

Unequipped


11.8  ED-ALS

Edit Automatic Laser Shutdown

Usage Guidelines

Cisco ONS 15454, ONS 15310-CL

This command is used to modify the ALS attributes of an OC-N facility and all the facilities that support the ALS feature. For MXP_2.5G_10E, TXP_MR_10E, MXP_2.5G_10G, TXP_MR_10G, TXP_MR_2.5G, and TXPP_MR_2.5G cards this command is used to modify the ALS parameter of the OC48 and OC192 ports.

Category

Ports

Security

Provisioning

Related Commands

DLT-<MOD1PAYLOAD>

DLT-FFP-<MOD2DWDMPAYLOAD>

DLT-FFP-<OCN_TYPE>

ED-<GIGE_TYPE>

ED-<MOD1FCPAYLOAD>

ED-<MOD1FICONPAYLOAD>

ED-<MOD2DWDMPAYLOAD>

ED-<OCN_TYPE>

ED-DS1

ED-EC1

ED-FFP-<MOD2DWDMPAYLOAD>

ED-FFP-<OCN_TYPE>

ED-G1000

ED-GFP

ED-HDLC

ED-POS

ED-T1

ED-T3

ED-TRC-<MOD2DWDMPAYLOAD>

ED-TRC-<OCN_TYPE>

ENT-<MOD1PAYLOAD>

ENT-FFP-<MOD2DWDMPAYLOAD>

ENT-FFP-<OCN_TYPE>

INIT-REG-<MOD2>

OPR-ALS

OPR-LPBK-<MOD2>

OPR-PROTNSW-<MOD2DWDMPAYLOAD>

OPR-PROTNSW-<OCN_TYPE>

REPT PM <MOD2>

RLS-LPBK-<MOD2>

RLS-PROTNSW-<MOD2DWDMPAYLOAD>

RLS-PROTNSW-<OCN_TYPE>

RMV-<MOD2>

RST-<MOD2>

RTRV-<MOD1FCPAYLOAD>

RTRV-<MOD1FICONPAYLOAD>

RTRV-<MOD2DWDMPAYLOAD>

RTRV-<OCN_TYPE>

RTRV-10GIGE

RTRV-ALMTH-<MOD2>

RTRV-ALS

RTRV-DS1

RTRV-EC1

RTRV-FAC

RTRV-FFP-<MOD2DWDMPAYLOAD>

RTRV-FFP-<OCN_TYPE>

RTRV-FSTE

RTRV-G1000

RTRV-GFP

RTRV-GIGE

RTRV-HDLC

RTRV-PM-<MOD2>

RTRV-PMSCHED-<MOD2>

RTRV-POS

RTRV-PROTNSW-<MOD2DWDMPAYLOAD>

RTRV-PROTNSW-<OCN_TYPE>

RTRV-T1

RTRV-T3

RTRV-TH-<MOD2>

RTRV-TRC-<MOD2DWDMPAYLOAD>

RTRV-TRC-<OCN_TYPE>

SCHED-PMREPT-<MOD2>

SET-ALMTH-<MOD2>

SET-TH-<MOD2>


Input Format

ED-ALS:[<TID>]:<SRC>:<CTAG>:::[ALSMODE=<ALSMODE>],[ALSRCINT=<ALSRCINT>],
[ALSRCPW=<ALSRCPW>][:];

Input Example

ED-ALS:CISCO:FAC-1-1:100:::ALSMODE=AUTO,ALSRCINT=130,ALSRCPW=35.1;

Input Parameters

Table 11-8 ED-ALS Input Parameters 

Parameter and Values
Description

SRC

Access identifier from the "AidUnionId" section

ALSMODE

ALS is enabled or disabled

Parameter type is ALS_MODE—the working mode for automatic laser shutdown

AUTO

Automatic

DISABLED

Disabled

MAN

Manual

MAN-RESTART

Manual restart for test

ALSRCINT

ALS recovery interval. The range is 60 to 300 seconds. Integer

ALSRCPW

ALS recovery pulse width. The range is 2.0 to 100.00 seconds, in increments of 100 ms. Float


11.9  ED-APC

Edit Amplification Power Control

Usage Guidelines

Cisco ONS 15454

This command is used to modify the APC application attributes. The default value for an optional parameter is the NE default value. The value might not be the current value for the parameter. Use a RTRV-xx command to retrieve the current value.

Category

DWDM

Security

Provisioning

Related Commands

DLT-LNK-<MOD2O>

DLT-LNKTERM

DLT-OSC

DLT-WLEN

ED-CLNT

ED-DWDM

ED-FFP-OCH

ED-LNK-<MOD2O>

ED-LNKTERM

ED-OCH

ED-OMS

ED-OSC

ED-OTS

ED-SLV-WDMANS

ED-TRC-OCH

ED-WDMANS

ED-WLEN

ENT-LNK-<MOD2O>

ENT-LNKTERM

ENT-OSC

ENT-WLEN

OPR-APC

OPR-LASER-OTS

OPR-PROTNSW-OCH

OPR-SLV-WDMANS

OPR-WDMANS

RLS-LASER-OTS

RLS-PROTNSW-OCH

RTRV-APC

RTRV-CLNT

RTRV-DWDM

RTRV-ESCON

RTRV-FFP-OCH

RTRV-LNK-<MOD2O>

RTRV-LNKTERM

RTRV-NE-APC

RTRV-NE-WDMANS

RTRV-OCH

RTRV-OMS

RTRV-OPM

RTRV-OSC

RTRV-OTS

RTRV-PROTNSW-OCH

RTRV-SLV-WDMANS

RTRV-TRC-OCH

RTRV-WDMANS

RTRV-WLEN


Input Format

ED-APC:[<TID>]::<CTAG>[:::APCENABLE=<APCENABLE>];

Input Example

ED-APC:PENNGROVE::CTAG:::APCENABLE=N;

Input Parameters

Table 11-9 ED-APC Input Parameters 

Parameter and Values
Description

APCENABLE

The enable/disable of the APC application. Default is N

Parameter type is ON_OFF—disable or enable an attribute

N

Disable an attribute

Y

Enable an attribute


11.10  ED-BITS

Edit Building Integrated Timing Supply

Usage Guidelines

Cisco ONS 15454, ONS 15327, ONS 15600, ONS 15310-CL

This command edits the BITS reference attributes.

SYNC-BITS1 and SYNC-BITS2 AIDs can be used to set the BITS-OUT port state. For a BITS facility, 64 k and 6 MHz are only applicable to ON. SSM selectable (ADMSSM) is not applicable to ONS 15600.

The default values for all optional parameters are NE default values. These values might not be the current value for a parameter. In order to obtain the current value, issue the RTRV-XX command.

Category

Synchronization

Security

Provisioning

Related Commands

ED-NE-SYNCN

ED-SYNCN

OPR-SYNCNSW

REPT ALM BITS

REPT ALM SYNCN

REPT EVT BITS

REPT EVT SYNCN

RLS-SYNCNSW

RTRV-ALM-BITS

RTRV-ALM-SYNCN

RTRV-BITS

RTRV-COND-BITS

RTRV-COND-SYNCN

RTRV-NE-SYNCN

RTRV-SYNCN


Input Format

ED-BITS:[<TID>]:<AID>:<CTAG>:::[LINECDE=<LINECDE>],[FMT=<FMT>],[LBO=<LBO>],
[SYNCMSG=<SYNCMSG>],[AISTHRSHLD=<AISTHRSHLD>],[SABIT=<SABIT>],
[BITSFAC=<BITSFAC>],[ADMSSM=<ADMSSM>][:<PST>];

Input Example

ED-BITS:SONOMA:BITS-2:779:::LINECDE=AMI,FMT=ESF,LBO=0-133,SYNCMSG=N,
AISTHRSHLD=PRS,SABIT=BYTE-5,IMPEDANCE=120-OHM,BITSFAC=T1,ADMSSM=PRS:IS;

Input Parameters

Table 11-10 ED-BITS Input Parameters 

Parameter and Values
Description

AID

Access identifier from the "BITS" section

LINECDE

Line code

Parameter type is LINE_CODE—line code

AMI

Line code value is AMI

B8ZS

Line code value is B8ZS (bipolar with three-zero substitution)

FMT

Digital signal frame format

Parameter type is FRAME_FORMAT—frame format for a T1 port

D4

Frame format is D4

ESF

Frame format is ESF

UNFRAMED

Frame format is unframed

LBO

Line build out settings. BITS line build out. Default value is 0 to 133. Integer

Parameter type is BITS_LineBuildOut—BITS line buildout

0-133

BITS line buildout range is 0-133

134-266

BITS line buildout range is 134-266

267-399

BITS line buildout range is 267-399

400-533

BITS line buildout range is 400-533

534-655

BITS line buildout range is 534-655

SYNCMSG

Indicates if the BITS facility supports synchronization status message. Default is on (Y)

Parameter type is EXT_RING—indicates if the ring supports the extended K1/K2/K3 protocol

N

The ring does not support the extended K1/K2/K3 protocol

Y

The ring does support the extended K1/K2/K3 protocol

AISTHRSHLD

Alarm indication signal threshold

Parameter type is SYNC_CLOCK_REF_QUALITY_LEVEL—clock source quality level for SONET

DUS

Do Not Use For Synchronization

PRS

Primary Reference Source, Stratum 1 Traceable

RES

Reserved For Network Synchronization Use

SMC

SONET Minimum Clock Traceable

ST2

Stratum 2 Traceable

ST3

Stratum 3 Traceable

ST3E

Stratum 3E Traceable

ST4

Stratum 4 Traceable

STU

Synchronized, Traceability Unknown

TNC

Transit Node Clock (2nd Generation Only)

SABIT

When the frame format selection is E1, SABIT is the bit used to receive and transmit the SSM

Parameter type is SABITS—SA BITS

BYTE-4

SABIT is BYTE-4

BYTE-5

SABIT is BYTE-5

BYTE-6

SABIT is BYTE-6

BYTE-7

SABIT is BYTE-7

BYTE-8

SABIT is BYTE-8

IMPEDANCE

When the frame format selection is E1, IMPEDANCE is the terminal impedance of the BITS-IN port

Parameter type is IMPEDANCE—the terminal impedance of the BITS-IN port

120-OHM

Impedance of 120 ohm

75-OHM

Impedance of 75 ohm

BITSFAC

BITS facility settings. BITS-2 always inherits the value of BITS-1

Parameter type is BITS_FAC—BITS facility rate. 64 k and 6 MHz are only applicable to the ONS 15454

2 M

2 MHz rate

64 K

64 K rate

6 M

6 MHz rate

E1

E1 rate

T1

T1 rate

ADMSSM

SSM selectable. Only applicable to BITS-IN when SSM is disabled.

Note Not applicable for ONS 15600

Parameter type is SYNC_CLOCK_REF_QUALITY_LEVEL—clock source quality level for SONET

DUS

Do Not Use For Synchronization

PRS

Primary Reference Source, Stratum 1 Traceable

RES

Reserved For Network Synchronization Use

SMC

SONET Minimum Clock Traceable

ST2

Stratum 2 Traceable

ST3

Stratum 3 Traceable

ST3E

Stratum 3E Traceable

ST4

Stratum 4 Traceable

STU

Synchronized, Traceability Unknown

TNC

Transit Node Clock (2nd Generation Only)

PST

Primary state

Parameter type is PST—indicates the current overall service condition of an entity

IS

In service

OOS

Out of service


11.11  ED-BULKROLL-<OCN_TYPE>

Edit Bulkroll (OC12, OC192, OC3, OC48)

Usage Guidelines

Cisco ONS 15454, ONS 15327, ONS 15600

This command edits information about rolling of traffic from one end point to another without interrupting service. This command uses the FORCE option to force a valid signal. The only parameters that can be edited are RMODE and FORCE. The time slots cannot be edited. Use ED-ROLL-<MOD_PATH> for single path level rolling.

See Table 27-1 for supported modifiers by platform.

Category

Bridge and Roll

Security

Provisioning

Related Commands

DLT-<MOD1PAYLOAD>

DLT-BULKROLL-<OCN_TYPE>

DLT-FFP-<MOD2DWDMPAYLOAD>

DLT-FFP-<OCN_TYPE>

ED-<GIGE_TYPE>

ED-<MOD1FCPAYLOAD>

ED-<MOD1FICONPAYLOAD>

ED-<MOD2DWDMPAYLOAD>

ED-<OCN_TYPE>

ED-ALS

ED-DS1

ED-DS3I

ED-EC1

ED-FFP-<MOD2DWDMPAYLOAD>

ED-FFP-<OCN_TYPE>

ED-FSTE

ED-G1000

ED-GFP

ED-HDLC

ED-POS

ED-T1

ED-T3

ENT-<MOD1PAYLOAD>

ENT-FFP-<MOD2DWDMPAYLOAD>

ENT-FFP-<OCN_TYPE>

INIT-REG-<MOD2>

OPR-ALS

OPR-LPBK-<MOD2>

OPR-PROTNSW-<MOD2DWDMPAYLOAD>

OPR-PROTNSW-<OCN_TYPE>

REPT PM <MOD2>

REPT RMV <MOD2_IO>

REPT RST <MOD2_IO>

RLS-LPBK-<MOD2>

RLS-PROTNSW-<MOD2DWDMPAYLOAD>

RLS-PROTNSW-<OCN_TYPE>

RMV-<MOD2>

RST-<MOD2>

RTRV-<MOD1FCPAYLOAD>

RTRV-<MOD1FICONPAYLOAD>

RTRV-<MOD2DWDMPAYLOAD>

RTRV-<OCN_TYPE>

RTRV-10GIGE

RTRV-ALMTH-<MOD2>

RTRV-ALS

RTRV-BULKROLL-<OCN_TYPE>

RTRV-DS1

RTRV-DS3I

RTRV-EC1

RTRV-FAC

RTRV-FFP-<MOD2DWDMPAYLOAD>

RTRV-FFP-<OCN_TYPE>

RTRV-FSTE

RTRV-G1000

RTRV-GFP

RTRV-GIGE

RTRV-HDLC

RTRV-PM-<MOD2>

RTRV-PMSCHED-<MOD2>

RTRV-POS

RTRV-PROTNSW-<MOD2DWDMPAYLOAD>

RTRV-PROTNSW-<OCN_TYPE>

RTRV-T1

RTRV-T3

RTRV-TH-<MOD2>

SCHED-PMREPT-<MOD2>

SET-ALMTH-<MOD2>

SET-TH-<MOD2>


Input Format

ED-BULKROLL-<OCN_TYPE>:[<TID>]:<FROM>:<CTAG>:::
[RFROMSTART=<RFROMSTART>],[RFROMEND=<RFROMEND>],[CMDMDE=<CMDMDE>];

Input Example

ED-BULKROLL-OC48:CISCO:FAC-1-1:1:::RFROMSTART=STS-1-1-1,
RFROMEND=STS-1-1-11,CMDMDE=FRCD;

Input Parameters

Table 11-11 ED-BULKROLL-<OCN_TYPE> Input Parameters 

Parameter and Values
Description

FROM

One of the end points. Access identifier from the "FACILITY" section for line level rolling and bulk rolling

RFROMSTART

The starting time slot in the source roll port. For bulk rolling only. The AID is from the "CrossConnectId1" section (except VCM and FACILITY). Defaults to STS-<FROMSLOT>-<FROMPORT>-1, where <FROMSLOT> and <FROMPORT> are the slot and port of the <FROM> AID.

RFROMEND

The ending time slot in the source roll port. For bulk rolling only. The AID is from the "CrossConnectId1" section (except VCM and FACILITY). Defaults to STS-<FROMSLOT>-<FROMPORT>-N, where <FROMSLOT> and <FROMPORT> are the slot and port of the <FROM> AID and N is the value of OCn. (for example, OC48, n=48)

CMDMDE

Command execution mode. Defaults to NORM

Parameter type is CMDMDE—forces the system to execute a given command regardless of any standing conditions. Normal mode is the default behavior for all commands but you can specify FRCD to force the system to override a state where the command would normally be denied

FRCD

Force the system to override a state where the command would normally be denied

NORM

Execute the command normally. Do not override any conditions that might make the command fail


11.12  ED-CMD-SECU

Edit Command Security

Usage Guidelines

Cisco ONS 15454, ONS 15327, ONS 15600, ONS 15310-CL

This command edits the command security level of a particular command.

Category

Security

Security

Superuser

Related Commands

ACT-USER

ALW-MSG-SECU

ALW-USER-SECU

CANC

CANC-USER

CANC-USER-SECU

CLR-COND-SECU

REPT ALM SECU

DLT-USER-SECU

ED-PID

ED-USER-SECU

ENT-USER-SECU

INH-MSG-SECU

INH-USER-SECU

REPT EVT SECU

REPT EVT SESSION

RTRV-CMD-SECU

RTRV-DFLT-SECU

RTRV-USER-SECU

SET-ATTR-SECUDFLT


Input Format

ED-CMD-SECU:[<TID>]:<AID>:<CTAG>::<CAP>;

Input Example

ED-CMD-SECU::INIT-REG:1::SU;

Input Parameters

Table 11-12 ED-CMD-SECU Input Parameters 

Parameter and Values
Description

AID

Access identifier string. Identifies the entity in the NE to which the command pertains. It is the command verb along with verb modifier(s), as it currently exists. It can be a single command or a block of commands, where the block might include all commands. Only INIT-REG will be supported. String. Must not be null

CAP

Command access privilege. Must not be null

Parameter type is PRIVILEGE—security level

MAINT

Maintenance security level. Unlimited idle time

PROV

Provision security level. 60 minutes of idle time

RTRV

Retrieve security level. 30 minutes of idle time

SUPER

Superuser security level. 15 minutes of idle time


11.13  ED-CRS-<PATH>

Edit Cross-Connect (STS1, STS12C, STS18C, STS192C, STS24C, STS36C, STS3C, STS48C, STS6C, STS9C, VT1, VT2)

Usage Guidelines

Cisco ONS 15454, ONS 15327, ONS 15600, ONS 15310-CL

See Table 27-1 for supported modifiers by platform.

This command edits a cross-connection.


NoteADD and REMOVE cannot be used together. The example provided is for informational purposes only. ADD and REMOVE are mutually exclusive.

Add/Remove drops is possible only on ONEWAY, UPSR_DROP, UPSR_DC, and UPSR_EN type of cross-connects (one-way only).

Traditional cross-connections cannot be upgraded to DRI cross-connections using the ED_CRS command.

CKTID is a string of ASCII characters. The maximum length of CKTID is 48. If the CKTID is EMPTY or NULL this field will not appear.

You cannot add a drop onto unidrectional connections on BLSR DRI primary or secondary nodes.


Category

Cross Connections

Security

Provisioning

Related Commands

DLT-CRS-<PATH>

ENT-CRS-<PATH>

RTRV-CRS

RTRV-CRS-<PATH>


Input Format

ED-CRS-<PATH>:[<TID>]:<SRC>,<DST>:<CTAG>:::[ADD=<ADD>],[REMOVE=<REMOVE>],
[CKTID=<CKTID>],[CMDMDE=<CMDMDE>]:[<PST>[,<SST>]];

Input Example

ED-CRS-STS3C::STS-1-1-1,STS-2-1-1:1:::ADD=STS-13-1-1,REMOVE=STS-2-1-1,CKTID=CKTID
CMDMDE=CMDMDE:IS,AINS;

Input Parameters

Table 11-13 ED-CRS-<PATH> Input Parameters 

Parameter and Values
Description

SRC

Source AID from the "CrossConnectId1" section

DST

Destination AID from the "CrossConnectId1" section

ADD

AID from the "AidUnionId" section

REMOVE

AID from the "AidUnionId" section

CKTID

String

CMDMDE

Command Mode. The FRCD mode of operation is applicable only if the PST=OOS and SST=DSBLD

Parameter type is CMDMDE—forces the system to execute a given command regardless of any standing conditions. Normal mode is the default behavior for all commands but you can specify FRCD to force the system to override a state where the command would normally be denied

FRCD

Force the system to override a state where the command would normally be denied

NORM

Execute the command normally. Do not override any conditions that might make the command fail

PST

Primary state

Parameter type is PST—indicates the current overall service condition of an entity

IS

In service

OOS

Out of service

SST

Secondary state

Parameter type is SST—provides additional information pertaining to PST and PSTQ

AINS

Automatic in service

DSBLD

Disabled

LPBK

Loopback

MEA

Mismatch of equipment and attributes

MT

Maintenance mode

OOG

Out of group

SWDL

Software downloading

UAS

Unassigned

UEQ

Unequipped


11.14  ED-DAT

Edit Date and Time

Usage Guidelines

Cisco ONS 15454, ONS 15327, ONS 15600, ONS 15310-CL

This command edits the date and the time

Category

System

Security

Provisioning

Related Commands

ACT-USER

ALW-MSG-ALL

ALW-MSG-DBCHG

ALW-MSG-SECU

ED-NE-GEN

ED-NE-PATH

ED-NE-SYNCN

INH-MSG-ALL

INH-MSG-DBCHG

INH-MSG-SECU

INIT-SYS

RTRV-HDR

RTRV-INV

RTRV-NE-GEN

RTRV-NE-IPMAP

RTRV-NE-PATH

RTRV-NE-SYNCN

RTRV-NE-WDMANS

RTRV-TOD

SET-TOD


Input Format

ED-DAT:[<TID>]::<CTAG>::[<DATE>],[<TIME>];

Input Example

ED-DAT:CISCO::1234::99-12-21,14-35-15;

Input Parameters

Table 11-14 ED-DAT Input Parameters 

Parameter and Values
Description

DATE

Date. String

TIME

Time. String


11.15  ED-DS1

Edit DS1

Usage Guidelines

Cisco ONS 15454

This command edits the test access attribute for DS1 access on a DS3XM card.


NoteThis command is not allowed if the card is a protect card.

Both the MODE and FMT fields of this command apply to the DS3XM-12 card only.

For the DS3XM-12 card, the DS1 frame format NE default is AUTO_PROV_FMT for the first 30 seconds to determine the real format. After 30 seconds, the DS1 frame format will be detected as FRAMED. If the frame format is not detected, it will be in the UNFRAMED format.

For preprovisioning the DS3XM-12 card, the DS1 frame format defaults to UNFRAMED.

For the DS3XM-12 card, the DS1 configurable attributes (PM, TH, alarm, etc.) only apply on the ported ports (1-12) and the VT-mapped (odd) portless ports in xxx-xxx-DS1 commands. If you provision or retrieve DS1 attributes on the DS3-mapped (even) portless port in xxx-xxx-DS1 commands, an error message will be returned.

The test set physical connection set up through ED-T3/DS1/STS1/VT1 of the DS3XM-12 card is only allowed on the physical front ports (PORTED ports, ports 1-12), which are the monitoring ports.

The monitoring test access ports follow the common rules for the other cards. For example, ED-T3 on port 2 (FAC-6-2) with a TACC number (8), the next port, port 3 (FAC-6-3) is used as the monitoring point also. The RTRV-T3 on both port-2 and port-3 return the same TACC number (8) being used to monitor the cross-connection end (A-B). The last port (port 12) is not allowed to set up a physical connection with the test set because there is no next available port to be the monitoring port.

The TACC disconnection (DISC-TACC) and the test access mode change command (CHG-TACC) follow the same requirement as in the step above, but it is applied on the ported ports of the DS3XM-12 card.

The test access connection set-up command (CONN-TACC) has monitored points, which can be portless ports. This command is applied on both ported and portless ports of the DS3XM-12 card.

If the entity has a TACC connection, the entity is not allowed to have ported or portless STS/VT cross-connection (or circuit) provisioning on the DS3XM-12 card.


Category

Ports

Security

Provisioning

Related Commands

DLT-FFP-<OCN_TYPE>

ED-<OCN_TYPE>

ED-EC1

ED-FFP-<OCN_TYPE>

ED-G1000

ED-GFP

ED-HDLC

ED-T1

ED-T3

ED-TRC-<OCN_TYPE>

ENT-FFP-<OCN_TYPE>

OPR-PROTNSW-<OCN_TYPE>

RLS-PROTNSW-<OCN_TYPE>

RTRV-<OCN_TYPE>

RTRV-DS1

RTRV-EC1

RTRV-FAC

RTRV-FFP-<OCN_TYPE>

RTRV-FSTE

RTRV-G1000

RTRV-GFP

RTRV-GIGE

RTRV-HDLC

RTRV-POS

RTRV-PROTNSW-<OCN_TYPE>

RTRV-T1

RTRV-T3

RTRV-TRC-<OCN_TYPE>


Input Format

ED-DS1:[<TID>]:<AID>:<CTAG>:::[TACC=<TACC>],[TAPTYPE=<TAPTYPE>],
[MODE=<MODE>],[FMT=<FMT>];

Input Example

ED-DS1:PETALUMA:DS1-2-1-6-12:123:::TACC=8,TAPTYPE=DUAL,MODE=FDL,FMT=ESF;

Input Parameters

Table 11-15 ED-DS1 Input Parameters 

Parameter and Values
Description

AID

Access identifier from the "DS1" section

TACC

TAP number within a range of 0 to 999. Indicates whether the digroup being provisioned is to be used as a test access digroup. When TACC is 0 (zero), the TAP is deleted. Integer

TAPTYPE

TAP type

Parameter type is TAPTYPE—test access point type

DUAL

Dual FAD

SINGLE

Single FAD

MODE

Mode with which the command is to be implemented. DS1 path mode of the DS3XM-12 card. Defaults to FDL

Parameter type is DS1MODE—the DS1 path mode of the DS3XM-12 card

ATT

The DS1 path of the DS3XM-12 card is in AT&T 54016 mode

FDL

The DS1 path of the DS3XM-12 card is in FDL T1-403 mode

FMT

Digital signal format. The DS1 path frame format of the DS3XM-12 card. Defaults to UNFRAMED

Parameter type is FRAME_FORMAT—frame format for a T1 port

D4

Frame format is D4

ESF

Frame format is ESF

UNFRAMED

Frame format is unframed


11.16  ED-EC1

Edit Electrical Carrier

Usage Guidelines

Cisco ONS 15454, ONS 15310-CL

This command edits the attributes of an EC1.


Note This command is not allowed if the card is a protecting card.


Category

Ports

Security

Provisioning

Related Commands

DLT-FFP-<OCN_TYPE>

ED-<OCN_TYPE>

ED-DS1

ED-FFP-<OCN_TYPE>

ED-G1000

ED-GFP

ED-HDLC

ED-T1

ED-T3

ED-TRC-<OCN_TYPE>

ENT-FFP-<OCN_TYPE>

OPR-PROTNSW-<OCN_TYPE>

RLS-PROTNSW-<OCN_TYPE>

RTRV-<OCN_TYPE>

RTRV-DS1

RTRV-EC1

RTRV-FAC

RTRV-FFP-<OCN_TYPE>

RTRV-FSTE

RTRV-G1000

RTRV-GFP

RTRV-GIGE

RTRV-HDLC

RTRV-POS

RTRV-PROTNSW-<OCN_TYPE>

RTRV-T1

RTRV-T3

RTRV-TRC-<OCN_TYPE>


Input Format

ED-EC1:[<TID>]:<AID>:<CTAG>:::[PJMON=<PJMON>],[LBO=<LBO>],[SOAK=<SOAK>],
[SFBER=<SFBER>],[SDBER=<SDBER>],[NAME=<NAME>],[EXPTRC=<EXPTRC>],
[TRC=<TRC>],[TRCMODE=<TRCMODE>],[<TRCFORMAT>],[AISONLPBK=<AISONLPBK>],
[CMDMDE=<CMDMDE>]:[<PST>[,<SST>]];

Input Example

ED-EC1:CISCO:FAC-1-1:123:::PJMON=0,LBO=0-225,SOAK=10,SFBER=1E-4,SDBER=1E-6,
NAME="EC1 PORT",EXPTRC="AAA",TRC="AAA",TRCMODE=MAN,TRCFORMAT="16-BYTE,
AISONLPBK=AIS_ON_LPBK_ALL,CMDMDE=CMDMDE:IS,AINS;

Input Parameters

Table 11-16 ED-EC1 Input Parameters 

Parameter and Values
Description

AID

Access identifier from the "FACILITY" section

PJMON

A SONET pointer number (0 or 1) of an EC1 port. Integer. Defaults to 0

LBO

Line build out settings. Integer. Defaults to 0-225

Parameter type is E_LBO—electrical signal line buildout

0-225

Electrical signal line buildout range is 0-225

226-450

Electrical signal line buildout range is 226-450

SOAK

IS-AINS to IS transition soak time as measured in 15-minute intervals. A value of 4 equals a soak time of 1 hour. The allowable range is 0 to 192 intervals (maximum of 48 hours). Integer. Defaults to 32

SFBER

Signal failure threshold. Defaults to 1E-4

Parameter type is SF_BER—the threshold for declaring signal failure on a facility or path

1E-3

SFBER is 1E-3

1E-4

SFBER is 1E-4

1E-5

SFBER is 1E-5

SDBER

Signal degrade threshold. Defaults to 1E-7

Parameter type is SD_BER—the threshold for declaring signal degrade on a facility or path

1E-5

SDBER is 1E-5

1E-6

SDBER is 1E-6

1E-7

SDBER is 1E-7

1E-8

SDBER is 1E-8

1E-9

SDBER is 1E-9

NAME

String. Default value is NULL. Maximum length is 32 characters

EXPTRC

String

TRC

String

TRCMODE

Trace mode

Parameter type is TRCMODE—trace mode

AUTO

Use the previously received path trace string as the expected string. Not applicable to MXP/TXP cards

AUTO-NO-AIS

Use the previously received path trace string as the expected string and do not turn on AIS and RDI if TIMP is detected

MAN

Use the provisioned expected string as the expected string

MAN-NO-AIS

Use the provisioned expected string as the expected string and do not turn on AIS and RDI if TIMP is detected

OFF

Turn off path trace capability. Nothing will be reported

TRCFORMAT

Trace message size

Parameter type is TRCFORMAT—trace format

1-BYTE

1 byte trace message

16-BYTE

16 byte trace message

64-BYTE

64 byte trace message

Y

Enable an attribute

AISONLPBK

Defaults to AIS_ONLPBK_FACILITY

Parameter type is AIS_ON_LPBK—Indicates if AIS is sent on a loopback

AIS_ONLPBK_FACILITY

AIS is sent on facility loopbacks

AIS_ON_LPBK_ALL

AIS is sent on all loopbacks

AIS_ON_LPBK_OFF

AIS is not sent on loopbacks

AIS_ON_LPBK_TERMINAL

AIS is sent on terminal loopbacks

CMDMDE

Command Mode. Defaults to NORM

Parameter type is CMDMDE—forces the system to execute a given command regardless of any standing conditions. Normal mode is the default behavior for all commands but you can specify FRCD to force the system to override a state where the command would normally be denied

FRCD

Force the system to override a state where the command would normally be denied

NORM

Execute the command normally. Do not override any conditions that might make the command fail

PST

Primary state. Defaults to IS

Parameter type is PST—indicates the current overall service condition of an entity

IS

In service

OOS

Out of service

SST

Secondary state. Defaults to AINS

Parameter type is SST—provides additional information pertaining to PST and PSTQ

AINS

Automatic in service

DSBLD

Disabled

LPBK

Loopback

MEA

Mismatch of equipment and attributes

MT

Maintenance mode

OOG

Out of group

SWDL

Software downloading

UAS

Unassigned

UEQ

Unequipped


11.17  ED-EQPT

Edit Equipment

Usage Guidelines

Cisco ONS 15454, ONS 15327, ONS 15600, ONS 15310-CL

This command edits the attributes for a given equipment slot in the NE. If the card is in an equipment slot, this command is allowed only on the working AID.


Note The ONS 15600 only supports these parameters: TID, AID, CTAG, PST and SST.


The PROTID parameter indicates the unique identifier of the protection group (the protect card). "NULL" is a special value of the PROTID parameter and indicates absence of a protection group. For the 1:1 protection type, RVRTV and RVTM parameters can be changed. For the 1:1 protection type, if the PROTID parameter is entered as "NULL", the protection group is deleted.

ED-EQPT:[<TID>]:SLOT-2:<CTAG>:::PROTID=NULL;

For the 1:N protection type, if the PROTID is "NULL", the AIDs in the list are removed from the protection group. If all the working cards are in the AID list, the protection group is deleted.

Example: if Slot-1, Slot-2 and Slot-4 were the only working cards in the protection group. The following command will remove Slot-4 from the protection group:

ED-EQPT:[<TID>]:SLOT-4:<CTAG>:::PROTID=NULL;

The protection group still has Slot-1 and Slot-2 as working cards.

The following command will remove all the other working cards in the above example and consequently, delete the protection group itself:

ED-EQPT:[<TID>]:SLOT-2&SLOT-1:<CTAG>:::PROTID=NULL;

The ED-EQPT command can be successfully executed on an already provisioned card to add or remove a working card from a protection group. This command is not valid on a protect card. Only cards can be added to or removed from a protection group. Protection type is immutable and is determined at the time of creation of a protection group (while adding the first working card). Once provisioned, the equipment type cannot be edited either.

Examples of adding an existing card to a protection group using the ED-EQPT command:

1:1 protection group

ED-EQPT::SLOT-2:12:::PROTID=SLOT-1,RVRTV=Y,RVTM=9.0;

1:N protection group

ED-EQPT::SLOT-2:12:::PROTID=SLOT-3,PRTYPE=1-N,RVTM=6.5;

Error conditions for editing a 1:1 or 1:N protection group might be:

1. Editing the PRTYPE or PROTID (non-NULL value) parameters.

2. Editing RVRTV or RVTM when no protection group exists.

3. Editing RVRTV for 1:N protection.

4. Failed to remove, currently switched to protect.

5. The CARDMODE provisioning is allowed on the DS3XM-12 and ML-Series cards

a. The DS3XM's provisioning is based on the XCON type and DS3XM-12's location. For example:

The DS3XM-12 card in the lower speed I/O slot with the XCVT/XC10G card only allows the DS3XM-12-STS12 CARDMODE. Other cases allow the CARDMODE to be DS3XM-12-STS-48

b. There is no card reboot if the CARDMODE is changed on the DS3XM-12 card.

c. The DS3XM-12 card can be upgraded or downgraded by changing the CARDMODE with the ED-EQPT command.

6. If the command mode (CMDMDE) is set to forced (FRCD) during the creation of a 1:1 or 1:N protection group, all cards must be physically plugged in and in the service state (IS). If the cards are not physically plugged in, then the command is denied with an appropriate error message. When the command mode is set to normal (NORM) (which is the default) the cards do not have to be physically plugged in and in the service state.

7. If the command mode is set to forced (FRCD) during the removal of a card in a 1:1 or 1:N protection group, there must be no cross-connects (for example, services) present on the card. If there are cross-connects present on the card, the command is denied with an appropriate error message. If the command mode is set to normal (NORM) (which is the default), it does not require that cross-connects be deleted on the card.


Note For the FC_MR-4 card, the card mode cannot be changed to FCMR-LINERATE when the payload on any port is 1GFICON or 2GFICON. These payloads are allowed only in distance extension card mode.


Category

Equipment

Security

Provisioning

Related Commands

ALW-SWDX-EQPT

ALW-SWTOPROTN-EQPT

ALW-SWTOWKG-EQPT

DLT-EQPT

ENT-EQPT

INH-SWDX-EQPT

INH-SWTOPROTN-EQPT

INH-SWTOWKG-EQPT

REPT ALM EQPT

REPT EVT EQPT

RTRV-ALM-EQPT

RTRV-ALMTH-EQPT

RTRV-COND-EQPT

RTRV-EQPT

SET-ALMTH-EQPT

SW-DX-EQPT

SW-TOPROTN-EQPT

SW-TOWKG-EQPT


Input Format

ED-EQPT:[<TID>]:<AID>:<CTAG>:::[PROTID=<PROTID>],[PRTYPE=<PRTYPE>],
[RVRTV=<RVRTV>],[RVTM=<RVTM>],[CMDMDE=<CMDMDE>],
[CARDMODE=<CARDMODE>],[PEERID=<PEERID>],[REGENNAME=<REGENNAME>],
[PWL=<PWL>],[RETIME=<RETIME>]:[<PST>[,<SST>]];

Input Example

ED-EQPT:CISCO:SLOT-2:123:::PROTID=SLOT-1,PRTYPE=1-1,RVRTV=Y,RVTM=9.0,
CMDMDE=FRCD,CARDMODE=DS3XM12-STS48,PEERID=SLOT-2,
REGENNAME="THIS GROUP",PWL=1530.33,RETIME=Y:OOS,MT;

Input Parameters

Table 11-17 ED-EQPT Input Parameters 

Parameter and Values
Description

AID

Access identifier from the "EQPT" section

PROTID

Protecting card slot number of the protection group from the "PRSLOT" section

PRTYPE

Protection group type

Parameter type is PROTECTION_GROUP—protection group type

1-1

1 for 1 protection group

1-N

1 for N protection group

RVRTV

Revertive mode. The value Y indicates that the protection switching system reverts service to the original line after restoration. The value N indicates that the protection switching system does not revert service to the original line after restoration. RVRTV is applicable only for 1+1 protection switching. Null defaults to N

Parameter type is ON_OFF—disable or enable an attribute

N

Disable an attribute

Y

Enable an attribute

RVTM

Revertive time

Parameter type is REVERTIVE_TIME—revertive time

0.5 to 12.0

Revertive time is 0.5 to 12.0 minutes

CMDMDE

Command mode. Only applicable when creating or deleting a protection group (1:1 or 1:N) and/or adding cards to an existing protection group (1:N). Default is NORM. If creating or adding cards to a protection group, specifying FRCD requires the card to be physically plugged in and in the service state (IS). If removing cards from a protection group (1:N) or deleting the protection group (1:1, 1:N), specifying FRCD requires that there are no cross-connects (services) on the card

Parameter type is CMDMDE—forces the system to execute a given command regardless of any standing conditions. Normal mode is the default behavior for all commands but you can specify FRCD to force the system to override a state where the command would normally be denied

FRCD

Force the system to override a state where the command would normally be denied

NORM

Execute the command normally. Do not override any conditions that might make the command fail

CARDMODE

Card mode

Note The card will reboot after the mode changes so the mode change request will not go through if all the ports on the card are not in OOS mode.

TL1 will not set a default CARD_MODE value at the management interface level if no PWL value is given

Parameter type is CARDMODE—card mode. Card mode is applicable to cards that have multiple capabilities, for example, the ML card can operate in two distinct modes: Linear Mapper Mode and L2/L3 Mode

DS3XM12-STS12

The DS3XM-12 card in the STS12 back plane rate mode

DS3XM12-STS48

The DS3XM-12 card in the STS48 back plane rate mode

DWDM-LINE

Line terminating mode

DWDM-SEC

Section terminating mode

DWDM-TRANS-AIS

Transparent mode AIS

DWDM-TRANS-SQUELCH

Transparent mode SQUELCH

FCMR-DISTEXTN

FC_MR-4 card with distance extension support

FCMR-LINERATE

FC_MR-4 card without distance extension support

ML-GFP

ML-Series card in DOS FPGA using GFP framing type

ML-HDLC

ML-Series card in DOS FPGA using HDLC framing type

MXPMR25G-FCGE

Fibre channel or GIGE mode for the MXP-MR-2.5G card

PEERID

The regeneration peer slot from the "EQPT" section

REGENNAME

The name of a regeneration group. String

PWL

Provisioned wavelength. TL1 will not set a default PWL value at the management level if no PWL value is given

Parameter type is OPTICAL_WLEN—optical wavelength

1530.33

Wavelength 1

1531.12

Wavelength 2

1531.90

Wavelength 3

1532.68

Wavelength 4

1534.25

Wavelength 5

1535.04

Wavelength 6

1535.82

Wavelength 7

1536.61

Wavelength 8

1538.19

Wavelength 9

1538.98

Wavelength 10

1539.77

Wavelength 11

1540.56

Wavelength 12

1542.14

Wavelength 13

1542.94

Wavelength 14

1543.73

Wavelength 15

1544.53

Wavelength 16

1546.12

Wavelength 17

1546.92

Wavelength 18

1547.72

Wavelength 19

1548.51

Wavelength 20

1550.12

Wavelength 21

1550.92

Wavelength 22

1551.72

Wavelength 23

1552.52

Wavelength 24

1554.13

Wavelength 25

1554.94

Wavelength 26

1555.75

Wavelength 27

1556.55

Wavelength 28

1558.17

Wavelength 29

1558.98

Wavelength 30

1559.79

Wavelength 31

1560.61

Wavelength 32

USE-TWL1

Use Tunable Wavelength 1

RETIME

Indicates if retiming is needed. Applicable only to the DS1-E1-56 card (ONS 15454)

Parameter type is YES_NO—whether the user's password is about to expire, the user is logged into the NE, or the user is locked out of the NE

NO

No

YES

Yes

PST

Primary state

Parameter type is PST—indicates the current overall service condition of an entity

IS

In service

OOS

Out of service

SST

Secondary state

Parameter type is SST—provides additional information pertaining to PST and PSTQ

AINS

Automatic in service

DSBLD

Disabled

LPBK

Loopback

MEA

Mismatch of equipment and attributes

MT

Maintenance mode

OOG

Out of group

SWDL

Software downloading

UAS

Unassigned

UEQ

Unequipped


11.18  ED-FAC

Edit Facility

Usage Guidelines

Cisco ONS 15454, ONS 15327, ONS 15600, ONS 15310-CL

This command provisions the payload (or signal) type of facility. The default values for all optional parameters are NE default values. These values might not be the current value for a parameter. In order to obtain the current value, issue the RTRV-XX command to retrieve them.

Category

Ports

Security

Provisioning

Related Commands

DLT-<MOD1PAYLOAD>

DLT-BULKROLL-<OCN_TYPE>

DLT-FFP-<MOD2DWDMPAYLOAD>

DLT-FFP-<OCN_TYPE>

ED-<GIGE_TYPE>

ED-<MOD1FCPAYLOAD>

ED-<MOD1FICONPAYLOAD>

ED-<MOD2DWDMPAYLOAD>

ED-<OCN_TYPE>

ED-ALS

ED-BULKROLL-<OCN_TYPE>

ED-DS1

ED-EC1

ED-FFP-<MOD2DWDMPAYLOAD>

ED-FFP-<OCN_TYPE>

ED-FSTE

ED-G1000

ED-GFP

ED-HDLC

ED-POS

ED-T1

ED-T3

ENT-<MOD1PAYLOAD>

ENT-BULKROLL-<OCN_TYPE>

ENT-FFP-<MOD2DWDMPAYLOAD>

ENT-FFP-<OCN_TYPE>

INIT-REG-<MOD2>

OPR-ALS

OPR-LPBK-<MOD2>

OPR-PROTNSW-<MOD2DWDMPAYLOAD>

OPR-PROTNSW-<OCN_TYPE>

REPT PM <MOD2>

RLS-LPBK-<MOD2>

RLS-PROTNSW-<MOD2DWDMPAYLOAD>

RLS-PROTNSW-<OCN_TYPE>

RMV-<MOD2>

RST-<MOD2>

RTRV-<MOD1FCPAYLOAD>

RTRV-<MOD1FICONPAYLOAD>

RTRV-<MOD2DWDMPAYLOAD>

RTRV-<OCN_TYPE>

RTRV-10GIGE

RTRV-ALMTH-<MOD2>

RTRV-ALS

RTRV-BFDLPM-<MOD2>

RTRV-BULKROLL-<OCN_TYPE>

RTRV-DS1

RTRV-EC1

RTRV-FAC

RTRV-FFP-<MOD2DWDMPAYLOAD>

RTRV-FFP-<OCN_TYPE>

RTRV-FSTE

RTRV-G1000

RTRV-GFP

RTRV-GIGE

RTRV-HDLC

RTRV-PM-<MOD2>

RTRV-PMSCHED-<MOD2>

RTRV-POS

RTRV-PROTNSW-<MOD2DWDMPAYLOAD>

RTRV-PROTNSW-<OCN_TYPE>

RTRV-T1

RTRV-T3

RTRV-TH-<MOD2>

SCHED-PMREPT-<MOD2>

SET-ALMTH-<MOD2>

SET-TH-<MOD2>


Input Format

ED-FAC:[<TID>]:<SRC>:<CTAG>:::[PAYLOAD=<PAYLOAD>],
[CMDMDE=<CMDMDE>]:[<PST>[,<SST>]];

Input Example

ED-FAC:CISCO:FAC-3-9:2222:::PAYLOAD=E4-FRAMED,CMDMDE=CMDMDE:IS,AINS;

Input Parameters

Table 11-18 ED-FAC Input Parameters 

Parameter and Values
Description

SRC

Source access identifier from the "FACILITY" section

PAYLOAD

The payload for the card

Parameter type is PAYLOAD—identifies payload type

10GFC

10 Gigabit Ethernet Fibre Channel mode

10GIGE

10 Gigabit Ethernet

1GFC

1 Gigabit Fibre Channel mode

1GFICON

1 Gigabit FICON mode

2GFC

2 Gigabit Fibre Channel mode

2GFICON

2 Gigabit FICON mode

DS3

DS3 mode

DV6000

Video mode

EC1

EC1 mode

ESCON

ESCON mode

ETRCLO

ETR/CLO payload mode

GIGE

Gigabit Ethernet Payload

HDTV

HDTV mode

ISC1

ISC1 Mode

ISC3

ISC3 Mode

OC12

SONET OC-12 mode

OC3

SONET OC-3 mode

OC48

SONET OC-48 mode

PASS-THROUGH

Pass through mode

SDI-D1-VIDEO

SDI-D1-Video mode

SONET

SONET Payload Mode

CMDMDE

Command Mode. Defaults to NORM

Parameter type is CMDMDE—forces the system to execute a given command regardless of any standing conditions. Normal mode is the default behavior for all commands but you can specify FRCD to force the system to override a state where the command would normally be denied

FRCD

Force the system to override a state where the command would normally be denied

NORM

Execute the command normally. Do not override any conditions that might make the command fail

PST

Primary state. Defaults to IS

Parameter type is PST—indicates the current overall service condition of an entity

IS

In service

OOS

Out of service

SST

Secondary state. Defaults to AINS

Parameter type is SST—provides additional information pertaining to PST and PSTQ

AINS

Automatic in service

DSBLD

Disabled

LPBK

Loopback

MEA

Mismatch of equipment and attributes

MT

Maintenance mode

OOG

Out of group

SWDL

Software downloading

UAS

Unassigned

UEQ

Unequipped


11.19  ED-FFP-<MOD2DWDMPAYLOAD>

Edit Facility Protection Group (10GFC, 10GIGE, 1GFC, 1GFICON, 2GFC, 2GFICON, D1VIDEO, DV6000, ETRCLO, GIGE, HDTV, ISC1)

Usage Guidelines

Cisco ONS 15454

This command edits a Y-cable protection group on client facilities.

Category

DWDM

Security

Provisioning

Related Commands

ALW-SWDX-EQPT

ALW-SWTOPROTN-EQPT

ALW-SWTOWKG-EQPT

DLT-FFP-<MOD2DWDMPAYLOAD>

DLT-FFP-<OCN_TYPE>

ED-FFP-<OCN_TYPE>

ED-FFP-OCH

ENT-FFP-<MOD2DWDMPAYLOAD>

ENT-FFP-<OCN_TYPE>

EX-SW-<OCN_BLSR>

INH-SWDX-EQPT

INH-SWTOPROTN-EQPT

INH-SWTOWKG-EQPT

OPR-PROTNSW-<OCN_TYPE>

REPT SW

RLS-PROTNSW-<OCN_TYPE>

RTRV-FFP-<MOD2DWDMPAYLOAD>

RTRV-FFP-<OCN_TYPE>

RTRV-FFP-OCH

RTRV-PROTNSW-<OCN_TYPE>

SW-DX-EQPT

SW-TOPROTN-EQPT

SW-TOWKG-EQPT


Input Format

ED-FFP-<MOD2DWDMPAYLOAD>:[<TID>]:<AID>:<CTAG>:::[PROTID=<PROTID>],
[RVRTV=<RVRTV>],[RVTM=<RVTM>],[PSDIRN=<PSDIRN>][:];

Input Example

ED-FFP-CLNT:CISCO:FAC-1-1:100:::PROTID=DC-METRO,RVRTV=N,RVTM=1.0,PSDIRN=BI;

Input Parameters

Table 11-19 ED-FFP-<MOD2DWDMPAYLOAD> Input Parameters 

Parameter and Values
Description

AID

Access identifier from the "FACILITY" section

PROTAID

The protection group identifier (protection group name). Defaults to the protecting port AID of the protection group. PROTAID can have a maximum length of 32 characters. String

RVRTV

Revertive mode. The value Y indicates that the protection switching system reverts service to the original line after restoration. The value N indicates that the protection switching system does not revert service to the original line after restoration. RVRTV is applicable only for 1+1 protection switching. Null defaults to N. Only applies to path protection

Parameter type is ON_OFF—disable or enable an attribute

N

Disable an attribute

Y

Enable an attribute

RVTM

Revertive time. RVTM is not allowed to be set while "RVRTV" is N. Only applies to path protection

Parameter type is REVERTIVE_TIME—revertive time

0.5 to 12.0

Revertive time is 0.5 to 12.0 minutes

PSDIRN

Protection switch operation. Identifies the switching mode. Defaults to UNI.

Note The MXP_2.5G_10G and TXP_MR_10G cards do not support BI-DIRECTIONAL switching

Parameter type is UNI_BI—unidirectional switch operations

BI

Bidirectional protection switching

UNI

Unidirectional protection switching


11.20  ED-FFP-<OCN_TYPE>

Edit Facility Protection Group (OC3, OC12, OC48, OC192)

Usage Guidelines

Cisco ONS 15454, ONS 15327, ONS 15600, ONS 15310-CL

See Table 27-1 for supported modifiers by platform.

This command edits the optical facility protection.


NoteThis command can be used on both protecting and working AIDs. Optimized 1+1 and related attributes are only applicable to the ONS 15454.

Optimized 1+1 and related attributes are only applicable to ONS 15454.

The default values for all optional parameters are NE default values. These values might not be the current value for a parameter. In order to obtain the current value, issue the RTRV-XX command to retrieve them.


Category

Protection

Security

Provisioning

Related Commands

ALW-SWDX-EQPT

ALW-SWTOPROTN-EQPT

ALW-SWTOWKG-EQPT

DLT-FFP-<MOD2DWDMPAYLOAD>

DLT-FFP-<OCN_TYPE>

ED-<OCN_TYPE>

ED-DS1

ED-EC1

ED-FFP-<MOD2DWDMPAYLOAD>

ED-FFP-OCH

ED-G1000

ED-GFP

ED-HDLC

ED-T1

ED-T3

ED-TRC-<OCN_TYPE>

ENT-FFP-<MOD2DWDMPAYLOAD>

ENT-FFP-<OCN_TYPE>

EX-SW-<OCN_BLSR>

INH-SWDX-EQPT

INH-SWTOPROTN-EQPT

INH-SWTOWKG-EQPT

RTRV-FFP-<MOD2DWDMPAYLOAD>

RTRV-FFP-<OCN_TYPE>

RTRV-FFP-OCH

RTRV-FSTE

RTRV-G1000

RTRV-GFP

RTRV-GIGE

RTRV-HDLC

RTRV-POS

RTRV-PROTNSW-<OCN_TYPE>

RTRV-T1

RTRV-T3

RTRV-TRC-<OCN_TYPE>

SW-DX-EQPT

SW-TOPROTN-EQPT

SW-TOWKG-EQPT

OPR-PROTNSW-<OCN_TYPE>

REPT SW

RLS-PROTNSW-<OCN_TYPE>

RTRV-<OCN_TYPE>

RTRV-DS1

RTRV-EC1

RTRV-FAC


Input Format

ED-FFP-<OCN_TYPE>:[<TID>]:<AID>:<CTAG>:::[PROTID=<PROTID>],
[RVRTV=<RVRTV>],[RVTM=<RVTM>],[PSDIRN=<PSDIRN>],[VRGRDTM=<VRGRDTM>],
[DTGRDTM=<DTGRDTM>],[RCGRDTM=<RCGRDTM>][:];

Input Example

ED-FFP-OC3:PETALUMA:FAC-1-1:1:::PROTID=PROT_NAME,RVRTV=Y,RVTM=1.0,
PSDIRN=BI,VRGRDTM=0.5,DTGRDTM=1.0,RCGRDTM=1.0;

Input Parameters

Table 11-20 ED-FFP-<OCN_TYPE> Input Parameters 

Parameter and Values
Description

AID

Access identifier from the "FACILITY" section

PROTAID

The protection group identifier (protection group name). PROTAID can have a maximum length of 32 characters. String

RVRTV

Revertive mode. The value Y indicates that the protection switching system reverts service to the original line after restoration. The value N indicates that the protection switching system does not revert service to the original line after restoration. RVRTV is applicable only for 1+1 protection switching. Null defaults to N

Parameter type is ON_OFF—disable or enable an attribute

N

Disable an attribute

Y

Enable an attribute

RVTM

Revertive time

Parameter type is REVERTIVE_TIME—revertive time

0.5 to 12.0

Revertive time is 0.5 to 12.0 minutes

PSDIRN

Protection switch operation. Indicates the switch mode. Defaults to UNI

Parameter type is UNI_BI—unidirectional and bidirectional switch operations

BI

Bidirectional protection switching

UNI

Unidirectional protection switching

VRGRDTM

Verification guard timer. Only applicable to optimized 1+1

Parameter type is VERIFICATION_GUARD_TIMER—optimized 1+1 verification guard timer

0.5

500 ms

1.0

1 second

DTGRDTM

Detection guard timer. Only applicable to optimized 1+1

Parameter type is DETECTION _GUARD_TIMER—optimized 1+1 detection guard timer

0.0

0 seconds

0.05

50 ms

0.1

100 ms

0.5

500 ms

1.0 to 5.0

1 second to 5 seconds

RCGRDTM

Recovery guard timer. Only applicable to optimized 1+1

Parameter type is RECOVERY_GUARD_TIMER—optimized 1+1 recovery guard timer

0.0

0 seconds

0.05

50 ms

0.1

100 ms

0.5

500 ms

1.0 to 10.0

1 second to 10 seconds


11.21  ED-FFP-OCH

Edit Facility Protection Group Optical Channel

Usage Guidelines

Cisco ONS 15454

This command changes the provisioning for the default protection group on the DWDM port of a TXP_MR_2.5G and TXPP_MR_2.5G card.

Category

DWDM

Security

Provisioning

Related Commands

ALW-SWDX-EQPT

ALW-SWTOPROTN-EQPT

ALW-SWTOWKG-EQPT

DLT-FFP-<MOD2DWDMPAYLOAD>

DLT-FFP-<OCN_TYPE>

DLT-LNK-<MOD2O>

ED-DWDM

ED-FFP-<MOD2DWDMPAYLOAD>

ED-FFP-<OCN_TYPE>

ED-LNK-<MOD2O>

ED-OCH

ED-OMS

ED-OTS

ED-TRC-OCH

ENT-FFP-<MOD2DWDMPAYLOAD>

ENT-FFP-<OCN_TYPE>

ENT-LNK-<MOD2O>

EX-SW-<OCN_BLSR>

INH-SWDX-EQPT

INH-SWTOPROTN-EQPT

INH-SWTOWKG-EQPT

OPR-LASER-OTS

OPR-PROTNSW-<OCN_TYPE>

OPR-PROTNSW-OCH

REPT SW

RLS-LASER-OTS

RLS-PROTNSW-<OCN_TYPE>

RLS-PROTNSW-OCH

RTRV-DWDM

RTRV-FFP-<MOD2DWDMPAYLOAD>

RTRV-FFP-<OCN_TYPE>

RTRV-FFP-OCH

RTRV-LNK-<MOD2O>

RTRV-OCH

RTRV-OMS

RTRV-OTS

RTRV-PROTNSW-<OCN_TYPE>

RTRV-PROTNSW-OCH

RTRV-TRC-OCH

SW-DX-EQPT

SW-TOPROTN-EQPT

SW-TOWKG-EQPT


Input Format

ED-FFP-OCH:[<TID>]:<AID>:<CTAG>:::[PROTID=<PROTID>],[RVRTV=<RVRTV>],
[RVTM=<RVTM>],[PSDIRN=<PSDIRN>][:];

Input Example

ED-FFP-OCH:VA454-22:CHAN-2-2:100:::PROTID="FIXEDPROTECTION",RVRTV=N,
RVTM=1.0,PSDIRN=BI;

Input Parameters

Table 11-21 ED-FFP-OCH Input Parameters 

Parameter and Values
Description

AID

Access identifier from the "CHANNEL" section

PROTAID

The protection group identifier (protection group name). String

RVRTV

Revertive mode. The value Y indicates that the protection switching system reverts service to the original line after restoration. The value N indicates that the protection switching system does not revert service to the original line after restoration. RVRTV is applicable only for 1+1 protection switching. Null defaults to N

Parameter type is ON_OFF—disable or enable an attribute

N

Disable an attribute

Y

Enable an attribute

RVTM

Revertive time

Parameter type is REVERTIVE_TIME—revertive time

0.5 to 12.0

Revertive time is 0.5 to 12.0 minutes

PSDIRN

Protection switch operation

Parameter type is TRANS_MODE—G1000 transponder mode

BI

Bidirectional

NONE

Not in transponder mode

UNI

Unidirectional


11.22  ED-FSTE

Edit Fast Ethernet

Usage Guidelines

Cisco ONS 15454, ONS 15310-CL

This command edits the front end port information of the fast (10/100 Mbps) Ethernet card.

The default values for all optional parameters are NE default values. These values might not be the current value for a parameter. In order to obtain the current value, issue the RTRV-XX command to retrieve them.


Note For the ML-100T-8 card, only the NAME parameter can be set.


Category

Ports

Security

Provisioning

Related Commands

DLT-<MOD1PAYLOAD>

DLT-FFP-<MOD2DWDMPAYLOAD>

DLT-FFP-<OCN_TYPE>

ED-<GIGE_TYPE>

ED-<MOD1FCPAYLOAD>

ED-<MOD1FICONPAYLOAD>

ED-<MOD2DWDMPAYLOAD>

ED-<OCN_TYPE>

ED-ALS

ED-DS1

ED-EC1

ED-FFP-<MOD2DWDMPAYLOAD>

ED-FFP-<OCN_TYPE>

ED-G1000

ED-GFP

ED-HDLC

ED-POS

ED-T1

ED-T3

ED-TRC-<MOD2DWDMPAYLOAD>

ED-TRC-<OCN_TYPE>

ENT-<MOD1PAYLOAD>

ENT-FFP-<MOD2DWDMPAYLOAD>

ENT-FFP-<OCN_TYPE>

INIT-REG-<MOD2>

OPR-ALS

OPR-LPBK-<MOD2>

OPR-PROTNSW-<MOD2DWDMPAYLOAD>

OPR-PROTNSW-<OCN_TYPE>

REPT PM <MOD2>

RLS-LPBK-<MOD2>

RLS-PROTNSW-<MOD2DWDMPAYLOAD>

RLS-PROTNSW-<OCN_TYPE>

RMV-<MOD2>

RST-<MOD2>

RTRV-<MOD1FCPAYLOAD>

RTRV-<MOD1FICONPAYLOAD>

RTRV-<MOD2DWDMPAYLOAD>

RTRV-<OCN_TYPE>

RTRV-10GIGE

RTRV-ALMTH-<MOD2>

RTRV-ALS

RTRV-DS1

RTRV-EC1

RTRV-FAC

RTRV-FFP-<MOD2DWDMPAYLOAD>

RTRV-FFP-<OCN_TYPE>

RTRV-FSTE

RTRV-G1000

RTRV-GFP

RTRV-GIGE

RTRV-HDLC

RTRV-PM-<MOD2>

RTRV-PMSCHED-<MOD2>

RTRV-POS

RTRV-PROTNSW-<MOD2DWDMPAYLOAD>

RTRV-PROTNSW-<OCN_TYPE>

RTRV-T1

RTRV-T3

RTRV-TH-<MOD2>

RTRV-TRC-<MOD2DWDMPAYLOAD>

RTRV-TRC-<OCN_TYPE>

SCHED-PMREPT-<MOD2>

SET-ALMTH-<MOD2>

SET-TH-<MOD2>


Input Format

ED-FSTE:[<TID>]:<AID>:<CTAG>:::[FLOW=<FLOW>],[EXPDUPLEX=<EXPDUPLEX>],
[EXPSPEED=<EXPSPEED>],[VLANCOS=<VLANCOS>],[IPTOS=<IPTOS>],
[NAME=<NAME>],[CMDMDE=<CMDMDE>],[SOAK=<SOAK>]:[<PST>[,<SST>]];

Input Example

ED-FSTE:CISCO:FAC-1-1:123:::FLOW=FLOW,EXPDUPLEX=EXPDUPLEX,
EXPSPEED=EXPSPEED, VLANCOS=VLANCOS,IPTOS=IPTOS,
NAME="FSTE PORT",CMDMDE=CMDMDE,SOAK=32:IS,AINS;

Input Parameters

Table 11-22 ED-FSTE Input Parameters 

Parameter and Values
Description

AID

Access identifier from the "FACILITY" section

FLOW

Flow control

Parameter type is ON_OFF—disable or enable an attribute

N

Disable an attribute

Y

Enable an attribute

EXPDUPLEX

Ethernet duplex mode

Parameter type is ETHER_DUPLEX—duplex mode

AUTO

Auto mode

FULL

Full mode

HALF

Half mode

EXPSPEED

Ethernet speed

Parameter type is ETHER_SPEED—Ethernet speed

100_MBPS

100 Mbps

10_GBPS

10 Gbps

10_MBPS

10 Mbps

1_GBPS

1 Gbps

AUTO

Auto

VLANCOS

Priority queuing threshold based on VLAN class of service of incoming Ethernet packets. Default value is 1175. Integer

IPTOS

Priority queuing threshold based on IP type of service of incoming Ethernet packets. Default value is 368. Integer

NAME

Name. String

CMDMDE

Command Mode. The FRCD mode of operation is applicable to delete a VCAT member cross-connect from IS-NR or OOS-AU,AINS service state

Parameter type is CMDMDE—forces the system to execute a given command regardless of any standing conditions. Normal mode is the default behavior for all commands but you can specify FRCD to force the system to override a state where the command would normally be denied

FRCD

Force the system to override a state where the command would normally be denied

NORM

Execute the command normally. Do not override any conditions that might make the command fail

SOAK

OOS-AINS to IS transition soak time as measured in 15 minute intervals, so a value of 4 translates to a soak time of 1 hour. The allowable range is 0 to 192 intervals (maximum of 48 hours). Integer

PST

Primary state

Parameter type is PST—indicates the current overall service condition of an entity

IS

In service

OOS

Out of service

SST

Secondary state

Parameter type is SST—provides additional information pertaining to PST and PSTQ

AINS

Automatic in service

DSBLD

Disabled

LPBK

Loopback

MEA

Mismatch of equipment and attributes

MT

Maintenance mode

OOG

Out of group

SWDL

Software downloading

UAS

Unassigned

UEQ

Unequipped


11.23  ED-G1000

Edit G1000

Usage Guidelines

Cisco ONS 15454

This command edits the attributes related to a G1000 port.

The default values for all optional parameters are NE default values. These values might not be the current value for a parameter. In order to obtain the current value, issue the RTRV-XX command.

Category

Ports

Security

Provisioning

Related Commands

DLT-FFP-<OCN_TYPE>

ED-<OCN_TYPE>

ED-DS1

ED-EC1

ED-FFP-<OCN_TYPE>

ED-GFP

ED-HDLC

ED-T1

ED-T3

ED-TRC-<OCN_TYPE>

ENT-FFP-<OCN_TYPE>

OPR-PROTNSW-<OCN_TYPE>

RLS-PROTNSW-<OCN_TYPE>

RTRV-<OCN_TYPE>

RTRV-DS1

RTRV-EC1

RTRV-FAC

RTRV-FFP-<OCN_TYPE>

RTRV-FSTE

RTRV-G1000

RTRV-GFP

RTRV-GIGE

RTRV-HDLC

RTRV-POS

RTRV-PROTNSW-<OCN_TYPE>

RTRV-T1

RTRV-T3

RTRV-TRC-<OCN_TYPE>


Input Format

ED-G1000:[<TID>]:<AID>:<CTAG>:::[MFS=<MFS>],[FLOW=<FLOW>],
[LOWMRK=<LOWMRK>],[HIWMRK=<HIWMRK>],[AUTONEG=<AUTONEG>],
[NAME=<NAME>],[CMDMDE=<CMDMDE>],[SOAK=<SOAK>]:[<PST>[,<SST>]];

Input Example

ED-G1000:TID:FAC-1-1:CTAG:::MFS=1548,FLOW=Y,LOWMRK=20,HIWMRK=492,
AUTONEG=Y,NAME="G1000 PORT",CMDMDE=FRCD,SOAK=32:OOS,DSBLD;

Input Parameters

Table 11-23 ED-G1000 Input Parameters 

Parameter and Values
Description

AID

Access identifier from the "FACILITY" section

MFS

Maximum frame size

Parameter type is MFS_TYPE—maximum frame size used by an Ethernet card

1548

Normal frame size

JUMBO

Jumbo frame size

FLOW

Flow control

Parameter type is ON_OFF—disable or enable an attribute

N

Disable an attribute

Y

Enable an attribute

LOWMRK

Low watermark value. Integer. Defaults to 25. LOWMRK is available starting with Release 4.0.1

HIWMRK

High watermark value. Integer. Defaults to 485

AUTONEG

Automatic negotiation. Defaults to Y

Parameter type is ON_OFF—disable or enable an attribute

N

Disable an attribute

Y

Enable an attribute

NAME

Name. String. Default is NULL. Maximum length is 32 characters

CMDMDE

Command execution mode

Parameter type is CMDMDE—forces the system to execute a given command regardless of any standing conditions. Normal mode is the default behavior for all commands but you can specify FRCD to force the system to override a state where the command would normally be denied

FRCD

Force the system to override a state where the command would normally be denied

NORM

Execute the command normally. Do not override any conditions that might make the command fail

SOAK

OOS-AINS to IS transition soak time as measured in 15-minute intervals. A value of 4 equals a soak time of 1 hour. The allowable range is 0 to 192 intervals (maximum of 48 hours). Integer. Defaults to 32

ENCAP

Encapsulation. String

PST

Primary state. Defaults to OOS

Parameter type is PST—indicates the current overall service condition of an entity

IS

In service

OOS

Out of service

SST

Secondary state. Defaults to DSBLD

Parameter type is SST—provides additional information pertaining to PST and PSTQ

AINS

Automatic in service

DSBLD

Disabled

LPBK

Loopback

MEA

Mismatch of equipment and attributes

MT

Maintenance mode

OOG

Out of group

SWDL

Software downloading

UAS

Unassigned

UEQ

Unequipped


11.24  ED-GFP

Edit Generic Framing Protocol

Usage Guidelines

Cisco ONS 15454, ONS 15310-CL, ONS 15600

This command applies to the ONS 15454 CE-100T-8 card, the ONS 15454 FC_MR-4 card, the ONS 15310-CL CE-100T-8 card and the ONS 15600 ASAP card.


NoteThe ONS 15600 only supports these parameters: TID, AID, CTAG and FCS.

This command does not apply to ONS 15310-CL ML-100T-8 card.

For the FC_MR-4 card, the parameters AUTOTHGFPBUF, GFPBUF and FILTER can be edited only if distance extension is enabled (set to B2B).


Category

Ports

Security

Provisioning

Related Commands

DLT-FFP-<OCN_TYPE>

ED-<OCN_TYPE>

ED-DS1

ED-EC1

ED-FFP-<OCN_TYPE>

ED-G1000

ED-HDLC

ED-T1

ED-T3

ED-TRC-<OCN_TYPE>

ENT-FFP-<OCN_TYPE>

OPR-PROTNSW-<OCN_TYPE>

RLS-PROTNSW-<OCN_TYPE>

RTRV-<OCN_TYPE>

RTRV-DS1

RTRV-EC1

RTRV-FAC

RTRV-FFP-<OCN_TYPE>

RTRV-FSTE

RTRV-G1000

RTRV-GFP

RTRV-GIGE

RTRV-HDLC

RTRV-POS

RTRV-PROTNSW-<OCN_TYPE>

RTRV-T1

RTRV-T3

RTRV-TRC-<OCN_TYPE>


Input Format

ED-GFP:[<TID>]:<AID>:<CTAG>:::[FCS=<FCS>],[AUTOTHGFPBUF=<AUTOTHGFPBUF>],
[GFPBUF=<GFPBUF>],[FILTER=<FILTER>];

Input Example

ED-GFP:CISCO:VFAC-1-0:123:::FCS=N,AUTOTHGFPBUF=Y,GFPBUF=16,FILTER=EGRESS;

Input Parameters

Table 11-24 ED-GFP Input Parameters 

Parameter and Values
Description

AID

Access identifier from the "FACILITY" section.

Note VFAC AID is used for the CE-100T-8 cards on ONS 15310-CL and ONS 15454 and ASAP cards on ONS 15600. ML-100T-8 GFP management is done through the Cisco IOS CLI and not through the TL1 interface. FAC AID is used for ONS 15454 FC_MR-4

FCS

Payload frame check sequence

Parameter type is FCS—frame check sequence

FCS-16

Frame check sequencing using 16 bits

FCS-32

Frame check sequencing using 32 bits

NONE

No frame check sequence

AUTOTHGFPBUF

Parameter type is ON_OFF—disable or enable an attribute

N

Disable an attribute

Y

Enable an attribute

FILTER

Parameter type is GFP_FILTER—filter feature in GFP

EGRESS

Activate filter feature on egress port

NONE

Turn off filter feature


11.25  ED-HDLC

Edit High-Level Data Link Control

Usage Guidelines

Cisco ONS 15600

This command edits HDLC-related attributes for HDLC-encapsulated payloads.

Category

Ports

Security

Provisioning

Related Commands

DLT-FFP-<OCN_TYPE>

ED-<OCN_TYPE>

ED-DS1

ED-EC1

ED-FFP-<OCN_TYPE>

ED-G1000

ED-GFP

ED-T1

ED-T3

ED-TRC-<OCN_TYPE>

ENT-FFP-<OCN_TYPE>

OPR-PROTNSW-<OCN_TYPE>

RLS-PROTNSW-<OCN_TYPE>

RTRV-<OCN_TYPE>

RTRV-DS1

RTRV-EC1

RTRV-FAC

RTRV-FFP-<OCN_TYPE>

RTRV-FSTE

RTRV-G1000

RTRV-GFP

RTRV-GIGE

RTRV-HDLC

RTRV-POS

RTRV-PROTNSW-<OCN_TYPE>

RTRV-T1

RTRV-T3

RTRV-TRC-<OCN_TYPE>


Input Format

ED-HDLC:[<TID>]:<SRC>:<CTAG>[:::FCS=<FCS>];

Input Example

ED-HDLC:TID:VFAC-SLOT-PORT:CTAG:::FCS=FCS-16;

Input Parameters

Table 11-25 ED-HDLC Input Parameters 

Parameter and Values
Description

SRC

Access identifier from the "FACILITY" section. The ONS 15600 ASAP card uses the VFAC AID

FCS

Payload frame check sequence

Parameter type is FCS—frame check sequence

FCS-16

Frame check sequence using 16 bits

FCS-32

Frame check sequence using 32 bits

NONE

No frame check sequence


11.26  ED-LNK-<MOD2O>

Edit Link (OCH, OMS, OTS)

Usage Guidelines

Cisco ONS 15454

This command edits an optical link state.

Category

DWDM

Security

Provisioning

Related Commands

DLT-LNK-<MOD2O>

ED-DWDM

ED-FFP-OCH

ED-OCH

ED-OMS

ED-OTS

ED-TRC-OCH

ENT-LNK-<MOD2O>

OPR-LASER-OTS

OPR-PROTNSW-OCH

RLS-LASER-OTS

RLS-PROTNSW-OCH

RTRV-DWDM

RTRV-FFP-OCH

RTRV-LNK-<MOD2O>

RTRV-OCH

RTRV-OMS

RTRV-OTS

RTRV-PROTNSW-OCH

RTRV-TRC-OCH


Input Format

ED-LNK-<MOD2O>:[<TID>]:<FROM>,
<TO>:<CTAG>:::[CMDMDE=<CMDMDE>]:[<PST>[,<SST>]];

Input Example

ED-LNK-OMS:PENNGROVE:BAND-6-1-TX,BAND-13-1-RX:114:::CMDMDE=CMDMDE:IS,
AINS;

Input Parameters

Table 11-26 ED-LNK-<MODO> Input Parameters 

Parameter and Values
Description

FROM

Identifier at one end of the optical link from the "BAND" section

TO

Identifier at the other end of the optical link from the "BAND" section

CMDMDE

Command Mode. The FRCD mode of operation is applicable to delete a VCAT member cross-connect from IS-NR or OOS-AU,AINS service state

Parameter type is CMDMDE—forces the system to execute a given command regardless of any standing conditions. Normal mode is the default behavior for all commands but you can specify FRCD to force the system to override a state where the command would normally be denied

FRCD

Force the system to override a state where the command would normally be denied

NORM

Execute the command normally. Do not override any conditions that might make the command fail

PST

Primary state

Note PST is not supported for OCH provisioning

Parameter type is PST—indicates the current overall service condition of an entity

IS

In service

OOS

Out of service

SST

Secondary state

Note SST is not supported for OCH provisioning

Parameter type is SST—provides additional information pertaining to PST and PSTQ

AINS

Automatic in service

DSBLD

Disabled

LPBK

Loopback

MEA

Mismatch of equipment and attributes

MT

Maintenance mode

OOG

Out of group

SWDL

Software downloading

UAS

Unassigned

UEQ

Unequipped


11.27  ED-LNKTERM

Edit Provisionable Patchcord Termination

Usage Guidelines

Cisco ONS 15454, ONS 15327, ONS 15310-CL

This command edits the attributes of a provisionable patchcord that has already been created. Only the remote end attributes (REMOTENODE, REMOTELNKTERMID) can be edited.


NoteNo two provisionable patchcord terminations on a node can have the same remote end link termination information. An attempt to modify an existing provisionable patchcord termination while not following the above restriction will lead to an error message being responsed.

If the provisionable patchcord termination does not exist, an error message will be responsed.

This command does not accept multiple and ALL AIDs.

REMOTENODE is a string with a maximum length of 20 characters.


Category

Provisionable Patchcords

Security

Provisioning

Related Commands

DLT-LNK-<MOD2O>

DLT-LNKTERM

DLT-OSC

DLT-WLEN

ED-DWDM

ED-FFP-OCH

ED-LNK-<MOD2O>

ED-OCH

ED-OMS

ED-OSC

ED-OTS

ED-SLV-WDMANS

ED-TRC-OCH

ED-WDMANS

ED-WLEN

ENT-LNK-<MOD2O>

ENT-LNKTERM

ENT-OSC

ENT-WLEN

OPR-LASER-OTS

OPR-PROTNSW-OCH

OPR-SLV-WDMANS

OPR-WDMANS

RLS-LASER-OTS

RLS-PROTNSW-OCH

RTRV-DWDM

RTRV-FFP-OCH

RTRV-LNK-<MOD2O>

RTRV-LNKTERM

RTRV-NE-WDMANS

RTRV-OCH

RTRV-OMS

RTRV-OSC

RTRV-OTS

RTRV-PROTNSW-OCH

RTRV-SLV-WDMANS

RTRV-TRC-OCH

RTRV-WDMANS

RTRV-WLEN


Input Format

ED-LNKTERM:[<TID>]:<AID>:<CTAG>:::[REMOTENODE=<REMOTENODE>],
[REMOTELNKTERMID=<REMOTELNKTERMID>];

Input Example

ED-LNKTERM::LNKTERM-1:CTAG:::REMOTENODE=172.20.208.226,
REMOTELNKTERMID=25;

Input Parameters

Table 11-27 ED-LNKTERM Input Parameters 

Parameter and Values
Description

AID

Access identifier from the "LNKTERM" section. Indicates a link (provisionable patchcord) termination on the local node

REMOTENODE

The node where the other end of the provisionable patchcord resides. This can be an IP address or a valid TID. Defaults to the IP address of the local node/existing value. String

REMOTELNKTERMID

The corresponding provisionable patchcord termination on the remote node (as specified by the REMOTENODE parameter). Integer value within the range of 1 to 65535. Defaults to existing value


11.28  ED-NE-GEN

Edit Network Element General

Usage Guidelines

Cisco ONS 15454, ONS 15327, ONS 15600, ONS 15310-CL

This command edits the node attributes of the NE.


NoteOnly the IPADDR, IPMASK, DEFRTR, IIOP PORT and node name can be modified with this command.

The node name can be a maximum of 20 characters. If the entered name exceeds 20 characters, an IPNV (Node Name Too Long) error message is returned.

An existing NTP timing source can be removed by setting the address to 0.0.0.0.

The maximum length of IPMASK is 18 characters. The default is the mask of the local IP address.

ETHIPADDR and ETHIPMASK are disabled in this command. ETHIPADDR and ETHIPMASK are used to show the Ethernet interface address and mask. Both default to the nodes' IP address and masks.



Caution Changing the IPADDR, IPMASK, or IIOP Port will cause a reset of the controller card.

Category

System

Security

Superuser

Related Commands

ACT-USER

ALW-MSG-ALL

ALW-MSG-DBCHG

ALW-MSG-SECU

ED-DAT

ED-NE-PATH

ED-NE-SYNCN

INH-MSG-ALL

INH-MSG-DBCHG

INH-MSG-SECU

INIT-SYS

RTRV-HDR

RTRV-INV

RTRV-NE-GEN

RTRV-NE-IPMAP

RTRV-NE-PATH

RTRV-NE-SYNCN

RTRV-NE-WDMANS

RTRV-TOD

SET-TOD


Input Format

ED-NE-GEN:[<TID>]::<CTAG>:::[NAME=<NAME>],[IPADDR=<IPADDR>],
[IPMASK=<IPMASK>],[DEFRTR=<DEFRTR>],[IIOPPORT=<IIOPPORT>],[NTP=<NTP>],
[ETHIPADDR=<ETHIPADDR>],[ETHIPMASK=<ETHIPMASK>],
[SUPPRESSIP=<SUPPRESSIP>];

Input Example

ED-NE-GEN:CISCO::123:::NAME=NODENAME,IPADDR=192.168.100.52,
IPMASK=255.255.255.0,DEFRTR=192.168.100.1,IIOPPORT=57790,
NTP=192.168.100.52,ETHIPADDR=172.20.208.225,ETHIPMASK=255.255.255.0,
SUPPRESSIP=NO;

Input Parameters

Table 11-28 ED-NE-GEN Input Parameters 

Parameter and Values
Description

NAME

Node name. String. Defaults to NULL

IPADDR

Node IP address. String

IPMASK

Node IP mask. String

DEFRTR

Node default router. String

IIOPPORT

Node IIOP port. Integer. Defaults to 57790

NTP

Node NTP timing origin address. String. Defaults to 0.0.0.0

ETHIPADDR

Not supported in this release

ETHIPMASK

Not supported in this release

SUPPRESSIP

Parameter type is YES_NO—whether the user's password is about to expire, the user is logged into the NE, or the user is locked out of the NE

NO

No

YES

Yes


11.29  ED-NE-PATH

Edit Network Element Path

Usage Guidelines

Cisco ONS 15454, ONS 15327, ONS 15310-CL

This command edits the path attributes of the NE. The default value for an optional parameter is the NE default value.

Category

System

Security

Provisioning

Related Commands

ACT-USER

ALW-MSG-ALL

ALW-MSG-DBCHG

ALW-MSG-SECU

ED-DAT

ED-NE-GEN

ED-NE-SYNCN

INH-MSG-ALL

INH-MSG-DBCHG

INH-MSG-SECU

INIT-SYS

RTRV-HDR

RTRV-INV

RTRV-NE-GEN

RTRV-NE-IPMAP

RTRV-NE-PATH

RTRV-NE-SYNCN

RTRV-NE-WDMANS

RTRV-TOD

SET-TOD


Input Format

ED-NE-PATH:[<TID>]::<CTAG>:::[PDIP=<PDIP>],[XCMODE=<XCMODE>];

Input Example

ED-NE-PATH:::CTAG:::PDIP=Y,XCMODE=MIXED;

Input Parameters

Table 11-29 ED-NE-PATH Input Parameters 

Parameter and Values
Description

PDIP

Flag used to indicate whether PDI-P should be generated on the outgoing VT structured STSs

Parameter type is ON_OFF—disable or enable an attribute

N

Disable an attribute

Y

Enable an attribute

XCMODE

Cross-connect mode

Parameter type is XCMODE—applicable only to a node with cross connect cards; XC-VXC-10G, XC-VXC-2.5G for example, that support cross connect mode change

MIXED

Both VT1 and VT2 cross connects can be provisioned on the node

VT1

Only VT1 cross connects can be provisioned on the node

VT2

Only VT2 cross connects can be provisioned on the node


11.30  ED-NE-SYNCN

Edit Network Element Synchronization

Usage Guidelines

Cisco ONS 15454, ONS 15327, ONS 15600, ONS 15310-CL

This command edits the synchronization attributes of the NE.


Note Although mixed mode timing is supported in this release, it is not recommended. Refer to the Cisco ONS SONET TL1 Reference Guide for more information.



Note The existing external and line modes have the same functionality in all ONS 15454 4.x and 5.x releases:

External mode: the node derives its timing from the BITS inputs

Line mode: the node derives its timing from the SONET line(s)

Mixed mode: the node derives its timing from the BITS input or SONET lines


Category

Synchronization

Security

Provisioning

Related Commands

ACT-USER

ALW-MSG-ALL

ALW-MSG-DBCHG

ALW-MSG-SECU

ED-BITS

ED-DAT

ED-NE-GEN

ED-NE-PATH

ED-SYNCN

INH-MSG-ALL

INH-MSG-DBCHG

INH-MSG-SECU

INIT-SYS

OPR-SYNCNSW

REPT ALM BITS

REPT ALM SYNCN

REPT EVT BITS

REPT EVT SYNCN

RLS-SYNCNSW

RTRV-ALM-BITS

RTRV-ALM-SYNCN

RTRV-BITS

RTRV-COND-BITS

RTRV-COND-SYNCN

RTRV-HDR

RTRV-INV

RTRV-NE-GEN

RTRV-NE-IPMAP

RTRV-NE-PATH

RTRV-NE-SYNCN

RTRV-NE-WDMANS

RTRV-SYNCN

RTRV-TOD

SET-TOD


Input Format

ED-NE-SYNCN:[<TID>]::<CTAG>:::[TMMD=<TMMD>],[SSMGEN=<SSMGEN>],
[QRES=<QRES>],[RVRTV=<RVRTV>],[RVTM=<RVTM>];

Input Example

ED-NE-SYNCN:CISCO::123:::TMMD=LINE,SSMGEN=GEN1,QRES=ABOVE-PRS,
RVRTV=Y,RVTM=8.0;

Input Parameters

Table 11-30 ED-NE-SYNCN Input Parameters 

Parameter and Values
Description

TMMD

Timing mode. A null value is equivalent to ALL

Parameter type is TIMING_MODE—timing mode for the current node

EXTERNAL

The node derives its clock from the BITS input

LINE

The node derives its clock from the SONET lines

MIXED

The node derives its clock from the mixed timing mode

SSMGEN

Synchronization status message set. A null value is equivalent to ALL

Parameter type is SYNC_GENERATION—synchronization status message set generation

GEN1

First generation SSM set

GEN2

Second generation SSM set

QRES

Quality of the RES. A null value is equivalent to ALL

Parameter type is SYNC_QUALITY_LEVEL—network synchronization quality level

ABOVE-PRS

Better than primary reference source. Valid setting for Generation-1 and Generation-2 SSM Set

ABOVE-SMC

Between SMC and ST3. Valid setting for Generation-1 and Generation-2 SSM Set

ABOVE-ST2

Between ST2 and STU. Valid setting for Generation-1 and Generation-2 SSM Set

ABOVE-ST3

For Generation-1 SSM set, between ST3 and ST2. For Generation-2 SSM set, between ST3 and ST3E

ABOVE-ST3E

Between ST3E and TNC. Valid setting only for Generation-2 SSM set

ABOVE-ST4

Between ST4 and ST3. Valid setting for Generation-1 and Generation-2 SSM Set

ABOVE-STU

Between STU and PRS. Valid setting for Generation-1 and Generation-2 SSM Set. This is Default Setting

ABOVE-TNC

Between TNC and ST2. Valid setting only for Generation-2 SSM set

BELOW-ST4

Below ST4 but still usable. Valid setting for Generation-1 and Generation-2 SSM Set

SAME-AS-DUS

Disable the RES message by equating it to DUS. Valid setting for Generation-1 and Generation-2 SSM Set

RVRTV

Revertive mode. The value Y indicates that the protection switching system reverts service to the original line after restoration. The value N indicates that the protection switching system does not revert service to the original line after restoration. RVRTV is applicable only for 1+1 protection switching. Null defaults to N. A null value is equivalent to ALL

Parameter type is ON_OFF—disable or enable an attribute

N

Disable an attribute

Y

Enable an attribute

RVTM

Revertive time. A null value is equivalent to ALL

Parameter type is REVERTIVE_TIME—revertive time

0.5 to 12.0

Revertive time is 0.5 to 12.0 minutes


11.31  ED-OCH

Edit Optical Channel (OCH)

Usage Guidelines

Cisco ONS 15454

This command edits the attributes (service parameters) and state of an OCH facility.

Refer to the Cisco ONS SONET TL1 Reference Guide for specific card provisioning rules.


Note Primary=OOS and secondary=AINS states do not apply to Ethernet mode.


Category

DWDM

Security

Provisioning

Related Commands

DLT-LNK-<MOD2O>

ED-DWDM

ED-FFP-OCH

ED-LNK-<MOD2O>

ED-OMS

ED-OTS

ED-TRC-OCH

ENT-LNK-<MOD2O>

OPR-LASER-OTS

OPR-PROTNSW-OCH

RLS-LASER-OTS

RLS-PROTNSW-OCH

RTRV-DWDM

RTRV-FFP-OCH

RTRV-LNK-<MOD2O>

RTRV-OCH

RTRV-OMS

RTRV-OTS

RTRV-PROTNSW-OCH

RTRV-TRC-OCH


Input Format

ED-OCH:[<TID>]:<AID>:<CTAG>:::[RDIRN=<RDIRN>],[EXPWLEN=<EXPWLEN>],
[VOAATTN=<VOAATTN>],[VOAPWR=<VOAPWR>],[CALOPWR=<CALOPWR>],
[CHPOWER=<CHPOWER>],[NAME=<PORTNAME>],[SFBER=<SFBER>],[SDBER=<SDBER>],
[COMM=<COMM>],[GCCRATE=<GCCRATE>],[OSDBER=<OSDBER>],[DWRAP=<DWRAP>],
[FEC=<FEC>],[PAYLOADMAP=<PAYLOADMAP>],[MACADDR=<MACADDR>],
[SYNCMSG=<SYNCMSG>],[SENDDUS=<SENDDUS>],[SOAK=<SOAK>],[OSPF=<OSPF>],
[MFS=<MFS>],[CMDMDE=<CMDMDE>]:[<PST>[,<SST>]];

Input Example

ED-OCH:CISCO:CHAN-6-2:114:::RDIRN=W-E,EXPWLEN=1530.32,VOAATTN=2.5,
VOAPWR=7.5,CALOPWR=0,CHPOWER=2.0,NAME="NYLINE",SFBER=1E-5,
SDBER=1E-6,COMM=DCC,GCCRATE=192K,OSDBER=1E-6,DWRAP=Y,FEC=STD,
PAYLOADMAP=ASYNCH,MACADDR=00-0E-AA-BB-CC-DD,SYNCMSG=N,
SENDDUS=Y,SOAK=10,OSPF=Y,MFS=2152,CMDMDE=CMDMDE:IS,AINS;

Input Parameters

Table 11-31 ED-OCH Input Parameters 

Parameter and Values
Description

AID

Access identifier from the "CHANNEL" section

RDIRN

Ring directionality of the optical line

Parameter type is RDIRN_MODE—the optical ring directionality

E-W

The direction of the signal is from east to west (clockwise)

W-E

The direction of the signal is from west to east (counterclockwise)

EXPWLEN

Optical wavelength for this port. Applicable only to the following cards: optical service channel cards, optical amplifier cards, dispersion compensation units, multiplexer and demultiplexer cards and OADM cards

Parameter type is OPTICAL_WLEN—optical wavelength

1530.33

Wavelength 1

1531.12

Wavelength 2

1531.90

Wavelength 3

1532.68

Wavelength 4

1534.25

Wavelength 5

1535.04

Wavelength 6

1535.82

Wavelength 7

1536.61

Wavelength 8

1538.19

Wavelength 9

1538.98

Wavelength 10

1539.77

Wavelength 11

1540.56

Wavelength 12

1542.14

Wavelength 13

1542.94

Wavelength 14

1543.73

Wavelength 15

1544.53

Wavelength 16

1546.12

Wavelength 17

1546.92

Wavelength 18

1547.72

Wavelength 19

1548.51

Wavelength 20

1550.12

Wavelength 21

1550.92

Wavelength 22

1551.72

Wavelength 23

1552.52

Wavelength 24

1554.13

Wavelength 25

1554.94

Wavelength 26

1555.75

Wavelength 27

1556.55

Wavelength 28

1558.17

Wavelength 29

1558.98

Wavelength 30

1559.79

Wavelength 31

1560.61

Wavelength 32

USE-TWL1

Use Tunable Wavelength 1

VOAATTN

The value of calibrated attenuation for the VOA. It is expressed in dBm. For the following cards: optical service channel, optical amplifier, dispersion compensation units, multiplexer and demultiplexer and OADM, the range is 0.0 to +30.0. Not supported for TXP or MXP cards. Float

VOAPWR

The value of calibrated output power that the VOA is going to set as a result of its attenuation. Applicable only to the following cards: optical service channel, optical amplifier, dispersion compensation units, multiplexer and demultiplexer and OADM. Float

CALOPWR

The value of the calibrated optical power expected for the line added to the calculated value which equals the total expected output power. Expressed in dBm. Applicable only to the following cards: optical service channel, optical amplifier, dispersion compensation units, multiplexer and demultiplexer and OADM. Defaults to 0 dBm. Float

CHPOWER

The value of per channel optical power expected to the OCH drop port of an AD-4C unit. CHPOWER is a float expressed in dBm

Parameter type is REVERTIVE_TIME—revertive time

0.5 to 12.0

Revertive time is 0.5 to 12.0 minutes

PORTNAME

Port name. String

SFBER

Signal failure threshold for the SONET payload. Can only be provisioned on the working port

Parameter type is SF_BER—the threshold for declaring signal failure on a facility or path

1E-3

SFBER is 1E-3

1E-4

SFBER is 1E-4

1E-5

SFBER is 1E-5

SDBER

Signal degrade threshold for the SONET payload. Can only be provisioned on the working port

Parameter type is SD_BER—the threshold for declaring signal degrade on a facility or path

1E-5

SDBER is 1E-5

1E-6

SDBER is 1E-6

1E-7

SDBER is 1E-7

1E-8

SDBER is 1E-8

1E-9

SDBER is 1E-9

COMM

The GCC or DCC is enabled or disabled. The GCC can be enabled only if the digital wrapper has been enabled for the card. The default is NONE. Rules for an MXP_2.5G_10G/TXP_MR_10G client port are; only the DCC can be provisioned, if the termination mode is not transparent and the payload is SONET. On an MXP_2.5G_10G/TXP_MR_10G DWDM port, the DCC can be enabled only if the G.709 is not enabled and if the payload is SONET and the termination mode is not transparent. On an MXP_2.5G_10G/TXP_MR_10G DWDM port, the GCC can be enabled if there is no DCC and the G.709 flag is enabled. On a TXP/MXP DWDM port, the DCC/GCC can be disabled only if there are no provisionable patchcord terminations provisioned on the trunk port

Parameter type is COMM_TYPE—out of band communications channel termination type

DCC

Section DCC type

GCC

Generic communication channel (OTN) type

NONE

Disable DCC or GCC if enabled

GCCRATE

The data rate of the GCC traffic. The default is 192 Kbps. For MXP_2.5G_10G/TXP_MR_10G cards this applies only to the DWDM port.

Note The 576K option is not supported for this release.

Parameter type is GCCRATE—the data rate of the GCC traffic

192K

192 kbps

576K

576 kbps

OSDBER

OTN SDBER. Can only be provisioned on the working port. Defaults to 1E-7

Parameter type is SD_BER—the threshold for declaring signal degrade on a facility or path

1E-5

SDBER is 1E-5

1E-6

SDBER is 1E-6

1E-7

SDBER is 1E-7

1E-8

SDBER is 1E-8

1E-9

SDBER is 1E-9

DWRAP

The G.709 digital wrapper. It is either on or off. The system default is ON. For MXP_2.5G_10G/TXP_MR_10G cards, this applies only to the DWDM port.

To enable G.709:

there should be no GCC on the DWDM port

the payload (where the card is configured) should not be UNFRAMED

To disable G.709:

there should be no GCC on the DWDM port

the FEC should be turned to off

there should be no overhead circuit created on the DWDM port

none of the client ports on the card should be part of a Y-cable protection group (MXP only)

Parameter type is ON_OFF—disable or enable an attribute

N

Disable an attribute

Y

Enable an attribute

FEC

Forward error correction. It can be enabled only if the G.709 is turned ON. It is either off or enabled in standard or enhanced mode. The system default is standard FE enabled. The FEC level PM and thresholds apply if the FEC is turned ON

Parameter type is FEC_MODE—specifies the type of forward error correction

ENH

Enhanced FEC is enabled

OFF

FEC is disabled

STD

Standard FEC is enabled

PAYLOADMAP

The type of payload mapping. It can be enabled only if the G.709 is turned ON and FEC is enabled

Parameter type is PAYLOAD_MAPPING—payload mapping mode

ASYNCH

Asynchronous mapping mode

ODU

ODU multiplex structure mode

SYNCH

Synchronous mapping mode

MACADDR

MAC address for the 10GigE payload. String

SYNCMSG

The facility be enabled to provide the synchronization clock. This does not apply to the TXPD-10G card. This applies to an MXPD-10G card, only if the payload is SONET/SDH and the card termination mode is as follows:
TRANSPARENT - All Client ports are available for all timing selections. All Trunk ports are not available.
LINE - All ports are available for all-timing selections

Parameter type is ON_OFF—disable or enable an attribute

N

Disable an attribute

Y

Enable an attribute

SENDDUS

The facility sends out a Do not Use for Sync message. This does not apply to the TXPD-10G card. This applies to an MXPD-10G card, only if the payload is SONET/SDH and the card termination mode is as follows:
TRANSPARENT- All Client ports are available for all timing selections. All Trunk ports are not available.
LINE - All ports are available for all-timing selections

Parameter type is ON_OFF—disable or enable an attribute

N

Disable an attribute

Y

Enable an attribute

SOAK

OOS-AINS to IS transition soak time as measured in 15-minute intervals. A value of 4 equals a soak time of 1 hour. The allowable range is 0 to 192 intervals (maximum of 48 hours). Integer

OSPF

Open shortest path first

Parameter type is EXT_RING—indicates if the ring supports the extended K1/K2/K3 protocol

N

The ring does not support the extended K1/K2/K3 protocol

Y

The ring does support the extended K1/K2/K3 protocol

MFS

Integer

CMDMDE

Command mode

Parameter type is CMDMDE—forces the system to execute a given command regardless of any standing conditions. Normal mode is the default behavior for all commands but you can specify FRCD to force the system to override a state where the command would normally be denied

FRCD

Force the system to override a state where the command would normally be denied

NORM

Execute the command normally. Do not override any conditions that might make the command fail

PST

Primary state

Parameter type is PST—indicates the current overall service condition of an entity

IS

In service

OOS

Out of service

SST

Secondary state

Parameter type is SST—provides additional information pertaining to PST and PSTQ

AINS

Automatic in service

DSBLD

Disabled

LPBK

Loopback

MEA

Mismatch of equipment and attributes

MT

Maintenance mode

OOG

Out of group

SWDL

Software downloading

UAS

Unassigned

UEQ

Unequipped


11.32  ED-OMS

Edit Optical Multiplex Section (OMS)

Usage Guidelines

Cisco ONS 15454

This command edits the attributes (service parameters) and state of an OMS facility.

Category

DWDM

Security

Provisioning

Related Commands

DLT-LNK-<MOD2O>

ED-DWDM

ED-FFP-OCH

ED-LNK-<MOD2O>

ED-OCH

ED-OTS

ED-TRC-OCH

ENT-LNK-<MOD2O>

OPR-LASER-OTS

OPR-PROTNSW-OCH

RLS-LASER-OTS

RLS-PROTNSW-OCH

RTRV-DWDM

RTRV-FFP-OCH

RTRV-LNK-<MOD2O>

RTRV-OCH

RTRV-OMS

RTRV-OTS

RTRV-PROTNSW-OCH

RTRV-TRC-OCH


Input Format

ED-OMS:[<TID>]:<AID>:<CTAG>:::[RDIRN=<RDIRN>],[EXPBAND=<EXPBAND>],
[VOAATTN=<VOAATTN>],[VOAPWR=<VOAPWR>],[CALOPWR=<CALOPWR>],
[CHPOWER=<CHPOWER>],[NAME=<NAME>],[SOAK=<SOAK>],
[CMDMDE=<CMDMDE>]:[<PST>[,<SST>]];

Input Example

ED-OMS:PENNGROVE:BAND-6-1:114:::RDIRN=W-E,EXPBAND=1530.32-1532.68,
VOAATTN=2.5,VOAPWR=7.5,CALOPWR=0.0,CHPOWER=2.0,NAME="OMS PORT",
SOAK=8,CMDMDE=CMDMDE:IS,AINS;

Input Parameters

Table 11-32 ED-OMS Input Parameters 

Parameter and Values
Description

AID

Access identifier from the "BAND" section

RDIRN

Ring directionality of the optical line

Parameter type is RDIRN_MODE—the optical ring directionality

E-W

The direction of the signal is from east to west (clockwise)

W-E

The direction of the signal is from west to east (counterclockwise)

EXPBAND

The expected value of band for this port

Parameter type is OPTICAL_BAND—optical band

1530.33 to 1532.68

Band 1

1534.25 to 1536.61

Band 2

1538.19 to 1540.56

Band 3

1542.14 to 1544.53

Band 4

1546.12 to 1548.51

Band 5

1550.12 to 1552.52

Band 6

1554.13 to 1556.55

Band 7

1558.17 to 1560.61

Band 8

USE-DEFAULT

This band is not yet configured/retrieved from unit

VOAATTN

The value of calibrated attenuation for the VOA expressed in dBm. The range is 0.0 to +30.0. Float

VOAPWR

The value of calibrated output power that the VOA is going to set as a result of its attenuation. Float

CALOPWR

The value of the calibrated optical power expected for the line added to the calculated value which equals the total expected output power. Expressed in dBm. Defaults to 0 dBm. Float

CHPOWER

The value of per channel optical power. Float expressed in dBm

Parameter type is REVERTIVE_TIME—revertive time

0.5 to 12.0

Revertive time is 0.5 to 12.0 minutes

NAME

Port name. String

SOAK

Integer. Defaults to 8

CMDMDE

Command mode

Parameter type is CMDMDE—forces the system to execute a given command regardless of any standing conditions. Normal mode is the default behavior for all commands but you can specify FRCD to force the system to override a state where the command would normally be denied

FRCD

Force the system to override a state where the command would normally be denied

NORM

Execute the command normally. Do not override any conditions that might make the command fail

PST

Primary state

Parameter type is PST—indicates the current overall service condition of an entity

IS

In service

OOS

Out of service

SST

Secondary state

Parameter type is SST—provides additional information pertaining to PST and PSTQ

AINS

Automatic in service

DSBLD

Disabled

LPBK

Loopback

MEA

Mismatch of equipment and attributes

MT

Maintenance mode

OOG

Out of group

SWDL

Software downloading

UAS

Unassigned

UEQ

Unequipped


11.33  ED-OSC

Edit Optical Service Channel (OSC)

Usage Guidelines

Cisco ONS 15454

This command edits the OSC (optical service channel) group attributes.

Category

DWDM

Security

Provisioning

Related Commands

DLT-LNK-<MOD2O>

DLT-LNKTERM

DLT-OSC

DLT-WLEN

ED-DWDM

ED-FFP-OCH

ED-LNK-<MOD2O>

ED-LNKTERM

ED-OCH

ED-OMS

ED-OTS

ED-SLV-WDMANS

ED-TRC-OCH

ED-WDMANS

ED-WLEN

ENT-LNK-<MOD2O>

ENT-LNKTERM

ENT-OSC

ENT-WLEN

OPR-LASER-OTS

OPR-PROTNSW-OCH

OPR-SLV-WDMANS

OPR-WDMANS

RLS-LASER-OTS

RLS-PROTNSW-OCH

RTRV-DWDM

RTRV-FFP-OCH

RTRV-LNK-<MOD2O>

RTRV-LNKTERM

RTRV-NE-WDMANS

RTRV-OCH

RTRV-OMS

RTRV-OSC

RTRV-OTS

RTRV-PROTNSW-OCH

RTRV-SLV-WDMANS

RTRV-TRC-OCH

RTRV-WDMANS

RTRV-WLEN


Input Format

ED-OSC:[<TID>]:<AID>:<CTAG>:::[RINGID=<RINGID>],[NODEID=<NODEID>];

Input Example

ED-OSC:PENNGROVE:OSC-1:114:::RINGID=1,NODEID=10;

Input Parameters

Table 11-33 ED-OSC Input Parameters 

Parameter and Values
Description

AID

Access identifier from the "OSC" section

RINGID

The OSC ring ID of the NE, up to six characters. Valid characters are A-Z and 0-9. String. Default value is "# of AID OSC-#". Integer

NODEID

The OSC node ID of the NE. NODEID ranges from 0 to 31. Integer


11.34  ED-OTS

Edit Optical Transport Section (OTS)

Usage Guidelines

Cisco ONS 15454

This command edits the attributes (service parameters) and state of an OTS facility.

Category

DWDM

Security

Provisioning

Related Commands

DLT-LNK-<MOD2O>

ED-DWDM

ED-FFP-OCH

ED-LNK-<MOD2O>

ED-OCH

ED-OMS

ED-TRC-OCH

ENT-LNK-<MOD2O>

OPR-LASER-OTS

OPR-PROTNSW-OCH

RLS-LASER-OTS

RLS-PROTNSW-OCH

RTRV-DWDM

RTRV-FFP-OCH

RTRV-LNK-<MOD2O>

RTRV-OCH

RTRV-OMS

RTRV-OTS

RTRV-PROTNSW-OCH

RTRV-TRC-OCH


Input Format

ED-OTS:[<TID>]:<AID>:<CTAG>:::[RDIRN=<RDIRN>],[VOAATTN=<VOAATTN>],
[VOAPWR=<VOAPWR>],[OFFSET=<OFFSET>],[CALTILT=<CALTILT>],[OSRI=<OSRI>],
[AMPLMODE=<AMPLMODE>],[CHPOWER=<CHPOWER>],[EXPGAIN=<EXPGAIN>],
[NAME=<NAME>],[SOAK=<SOAK>],[CMDMDE=<CMDMDE>]:<PST>,[<SST>];

Input Example

ED-OTS:PENNGROVE:LINE-6-1:114:::RDIRN=W-E,VOAATTN=5.0,VOAPWR=10.0,OFFSET=0.0,CALTILT=0.0,OSRI=N,AMPLMODE=GAIN,CHPOWER=10.0,EXPGAIN=-5.0,
NAME="OTS PORT",SOAK=8,CMDMDE=CMDMDE:IS,AINS;

Input Parameters

Table 11-34 ED-OTS Input Parameters 

Parameter and Values
Description

AID

Access identifier from the "LINE" section

RDIRN

Ring directionality of the optical line

Parameter type is RDIRN_MODE—the optical ring directionality

E-W

The direction of the signal is from east to west (clockwise)

W-E

The direction of the signal is from west to east (counterclockwise)

VOAATTN

The value of calibrated attenuation for the VOA expressed in dBm. The range is 0.0 to +30.0. Float

VOAPWR

The value of calibrated output power that the VOA is going to set as a result of its attenuation. Float

OFFSET

The calibration value of the optical power added to the calculated reference value. Defaults to 0 dBm. Float

CALTILT

The amplifier calibration tilt offset to be added to the calculated reference value. Defaults to 0 dBm. Float. Optional

OSRI

OSRI enabled or disabled. Present only on a port where the safety is supported. Optional

Parameter type is ON_OFF—disable or enable an attribute

N

Disable an attribute

Y

Enable an attribute

AMPLMODE

The optical amplification control mode

Parameter type is AMPL_MODE—defines amplifier control mode

GAIN

The amplifier always maintains a fixed gain

POWER

The amplifier maintains the output power to a fixed value

CHPOWER

The per channel optical power. Float

EXPGAIN

The gain expected value to be reached from an amplifier when the node is part of a DWDM access network. Float

NAME

The name of the port. String

SOAK

Integer. Defaults to 8

CMDMDE

Command mode

Parameter type is CMDMDE—forces the system to execute a given command regardless of any standing conditions. Normal mode is the default behavior for all commands but you can specify FRCD to force the system to override a state where the command would normally be denied

FRCD

Force the system to override a state where the command would normally be denied

NORM

Execute the command normally. Do not override any conditions that might make the command fail

PST

Primary state

Parameter type is PST—indicates the current overall service condition of an entity

IS

In service

OOS

Out of service

SST

Secondary state

Parameter type is SST—provides additional information pertaining to PST and PSTQ

AINS

Automatic in service

DSBLD

Disabled

LPBK

Loopback

MEA

Mismatch of equipment and attributes

MT

Maintenance mode

OOG

Out of group

SWDL

Software downloading

UAS

Unassigned

UEQ

Unequipped


11.35  ED-PID

Edit Password

Usage Guidelines

Cisco ONS 15454, ONS 15327, ONS 15600, ONS 15310-CL

This command allows a user to change his or her own password.


NotePasswords are masked for the following security commands: ACT-USER, ED-PID, ENT-USER-SECU and ED-USER-SECU. Access to a TL1 session by any means will have the password masked. The CTC Request History and Message Log will also show the masked commands. When a password-masked command is reissued by double-clicking the command from CTC Request History, the password will still be masked in the CTC Request History and Message Log. The actual password that was previously issued will be sent to the NE. To use a former command as a template only, single-click the command in CTC Request History. The command will be placed in the Command Request text box, where you can edit the appropriate fields prior to reissuing it.

The password will not appear in the TL1 log on the NE.

For the ED-PID command:

ED-PID:[TID]:<UID>:[CTAG]::<OLDPID>,<NEWPID>;

The syntax of OLDPID is not checked. The NEWPID is required to follow Telcordia standards (for example, 10 characters maximum including 1 letter, 1 number, and any one of the following characters: #, %, or +). The OLDPID must match what is in the database.

You must use the ED-USER-SECU command to change the default password for the CISCO15 superuser.

The ED-PID command cannot be used to change the empty password to a valid password.


Category

Security

Security

Retrieve

Related Commands

ACT-USER

ALW-MSG-SECU

ALW-USER-SECU

CANC

CANC-USER

CANC-USER-SECU

CLR-COND-SECU

DLT-USER-SECU

ED-CMD-SECU

ED-USER-SECU

ENT-USER-SECU

INH-MSG-SECU

INH-USER-SECU

REPT ALM SECU

REPT EVT SECU

REPT EVT SESSION

RTRV-CMD-SECU

RTRV-DFLT-SECU

RTRV-USER-SECU

SET-ATTR-SECUDFLT


Input Format

ED-PID:[<TID>]:<UID>:<CTAG>::<OLDPID>,<NEWPID>;

Input Example

ED-PID:CISCO:UID:123::OLDPWD,NEWPWD;

Input Parameters

Table 11-35 ED-PID Input Parameters 

Parameter and Values
Description

UID

User identifier. Up to 10 alphanumeric characters. String

OLDPID

The user's old password. Up to 10 alphanumeric characters. Passwords are encrypted and will appear as asterisks (*). String

NEWPID

The user's new password. Up to 10 alphanumeric characters. Passwords are encrypted and will appear as asterisks (*). String


11.36  ED-POS

Edit Packet Over SONET

Usage Guidelines

Cisco ONS 15454, ONS 15310-CL, ONS 15600

This command edits the back end port information for the Ethernet card when the back end port is working in POS mode. The default values for all optional parameters are NE default values. These values might not be the current value for a parameter. In order to obtain the current value, issue the RTRV-XX command to retrieve them. ED-POS cannot set ENCAP and PST/SST.


Note This command is supported for the ONS 15454 CE-100T-8 card, the ONS 15310-CL ML-100T-8 and CE-100T-8 cards and the ONS 15600 ASAP card.


Category

Ports

Security

Provisioning

Related Commands

DLT-<MOD1PAYLOAD>

DLT-FFP-<MOD2DWDMPAYLOAD>

DLT-FFP-<OCN_TYPE>

ED-<GIGE_TYPE>

ED-<MOD1FCPAYLOAD>

ED-<MOD1FICONPAYLOAD>

ED-<MOD2DWDMPAYLOAD>

ED-<OCN_TYPE>

ED-ALS

ED-DS1

ED-EC1

ED-FFP-<MOD2DWDMPAYLOAD>

ED-FFP-<OCN_TYPE>

ED-FSTE

ED-G1000

ED-GFP

ED-HDLC

ED-T1

ED-T3

ED-TRC-<MOD2DWDMPAYLOAD>

ED-TRC-<OCN_TYPE>

ENT-<MOD1PAYLOAD>

ENT-FFP-<MOD2DWDMPAYLOAD>

ENT-FFP-<OCN_TYPE>

INIT-REG-<MOD2>

OPR-ALS

OPR-LPBK-<MOD2>

OPR-PROTNSW-<MOD2DWDMPAYLOAD>

OPR-PROTNSW-<OCN_TYPE>

REPT PM <MOD2>

RLS-LPBK-<MOD2>

RLS-PROTNSW-<MOD2DWDMPAYLOAD>

RLS-PROTNSW-<OCN_TYPE>

RMV-<MOD2>

RST-<MOD2>

RTRV-<MOD1FCPAYLOAD>

RTRV-<MOD1FICONPAYLOAD>

RTRV-<MOD2DWDMPAYLOAD>

RTRV-<OCN_TYPE>

RTRV-10GIGE

RTRV-ALMTH-<MOD2>

RTRV-ALS

RTRV-DS1

RTRV-EC1

RTRV-FAC

RTRV-FFP-<MOD2DWDMPAYLOAD>

RTRV-FFP-<OCN_TYPE>

RTRV-FSTE RTRV-G1000

RTRV-GFP

RTRV-GIGE

RTRV-HDLC

RTRV-PM-<MOD2>

RTRV-PMSCHED-<MOD2>

RTRV-POS

RTRV-PROTNSW-<MOD2DWDMPAYLOAD>

RTRV-PROTNSW-<OCN_TYPE>

RTRV-T1

RTRV-T3

RTRV-TH-<MOD2>

RTRV-TRC-<MOD2DWDMPAYLOAD>

RTRV-TRC-<OCN_TYPE>

SCHED-PMREPT-<MOD2>

SET-ALMTH-<MOD2>

SET-TH-<MOD2>


Input Format

ED-POS:[<TID>]:<AID>:<CTAG>:::[ENCAP=<ENCAP>],[NAME=<NAME>],
[CMDMDE=<CMDMDE>],[SOAK=<SOAK>]:[<PST>[,<SST>]];

Input Example

ED-POS:CISCO:VFAC-2-0:123:::ENCAP=HDLC,NAME=NAME,CMDMDE=CMDMDE,
SOAK=32:IS,AINS;

Input Parameters

Table 11-36 ED-POS Input Parameters 

Parameter and Values
Description

AID

Access identifier from the "FACILITY" section

ENCAP

Encapsulation

Parameter type is ENCAP—frame encapsulation type

GFP_F

GFP frame mode

GFP_T

GFP transparent mode

HDLC

HDLC frame mode

HDLC_LEX

HDLC LAN extension frame mode

HDLC_X86

HDLC X.86 frame mode

NAME

Port name. String

CMDMDE

Command Mode. The FRCD mode of operation is applicable to delete a VCAT member cross-connect from IS-NR or OOS-AU,AINS service state

Parameter type is CMDMDE—forces the system to execute a given command regardless of any standing conditions. Normal mode is the default behavior for all commands but you can specify FRCD to force the system to override a state where the command would normally be denied

FRCD

Force the system to override a state where the command would normally be denied

NORM

Execute the command normally. Do not override any conditions that might make the command fail

SOAK

OOS-AINS to IS transition soak time as measured in 15 minute intervals, so a value of 4 translates to a soak time of 1 hour. The allowable range is 0 to 192 intervals (maximum of 48 hours). Integer

PST

Primary state

Parameter type is PST—indicates the current overall service condition of an entity

IS

In service

OOS

Out of service

SST

Secondary state

Parameter type is SST—provides additional information pertaining to PST and PSTQ

AINS

Automatic in service

DSBLD

Disabled

LPBK

Loopback

MEA

Mismatch of equipment and attributes

MT

Maintenance mode

OOG

Out of group

SWDL

Software downloading

UAS

Unassigned

UEQ

Unequipped


11.37  ED-PROTOCOL

Edit Protocol

Usage Guidelines

Cisco ONS 15454, ONS 15327, ONS 15600, ONS 15310-CL

This command is used to enable/disable a protocol/service that is supported in the NE. Valid protocols include shell/file system access (SHELL), EMS, TL1 and SNMP.


Note If the AID is TL1 the command will be denied because TL1 users are not allowed to change the setting for TL1 protocol.



Note If the AID is SNMP the SECURE PROTOCOLSTAT is not supported. SNMP can only be enabled or disabled. To enable SNMP, set PROTOCOLSTAT to UNSECURE.


Category

Security

Security

Superuser

Related Commands

ACT-USER

ALW-CONSOLE-PORT

ALW-MSG-SECU

ALW-USER-SECU

CANC

CANC-USER

CANC-USER-SECU

CLR-COND-SECU

DLT-USER-SECU

ED-CMD-SECU

ED-PID

ED-USER-SECU

ENT-USER-SECU

INH-CONSOLE-PORT

INH-MSG-SECU

INH-USER-SECU

REPT ALM SECU

REPT EVT SECU

REPT EVT SESSION

RTRV-AUDIT-LOG

RTRV-CMD-SECU

RTRV-CONSOLE-PORT

RTRV-DFLT-SECU

RTRV-USER-SECU

SET-ATTR-SECUDFLT


Input Format

ED-PROTOCOL:[<TID>]:<PROTOCOLAID>:<CTAG>::<PROTOCOLSTAT>;

Input Example

ED-PROTOCOL:CISCONODE:EMS:123::SECURE;

Input Parameters

Table 11-37 ED-PROTOCOL Input Parameters 

Parameter and Values
Description

PROTOCOLAID

The protocol/service to which the command pertains

Parameter type is PROTOCOLAID—AID for protocol/service

EMS

CTC/CTM protocol/service

SHELL

Shell/file system access protocol

SNMP

SNMP protocol/service

TL1

TL1 protocol service

PROTOCOLSTAT

Identifies the status of the protocol/service

Parameter type is PROTOCOLSTAT—status of the protocol

DISABLED

The protocol cannot be used

SECURE

The protocol is enabled and communications using the protocol are sure, for example, through SSH. Not applicable for SNMP protocols

UNSECURE

The protocol is enabled but communication is not secure, for example, through telnet


11.38  ED-ROLL-<MOD_PATH>

Edit Roll (STS1, STS12C, STS192C, STS24C, STS3C, STS48C, STS6C, STS9C, VT1, VT2)

Usage Guidelines

Cisco ONS 15454, ONS 15327, ONS 15600

This command forces a rolling operation. Force attempts to force a valid signal to complete the rolling operation.

See Table 27-1 for supported modifiers by platform.


Note STS18C and STS36C are not supported for this command in this release.


Category

Bridge and Roll

Security

Provisioning

Related Commands

DLT-BULKROLL-<MOD_PATH>

DLT-CRS-<PATH>

DLT-ROLL-<MOD_PATH>

ED-<MOD_PATH>

ED-BULKROLL-<MOD_PATH>

ED-CRS-<PATH>

ED-NE-PATH

ENT-BULKROLL-<MOD_PATH>

ENT-CRS-<PATH>

ENT-ROLL-<MOD_PATH>

OPR-PROTNSW-<PATH>

RLS-PROTNSW-<PATH>

RTRV-<PATH>

RTRV-BULKROLL-<MOD_PATH>

RTRV-CRS-<PATH>

RTRV-NE-PATH

RTRV-PROTNSW-<PATH>

RTRV-PTHTRC-<PATH>

RTRV-ROLL-<MOD_PATH>


Input Format

ED-ROLL-<MOD_PATH>:[<TID>]:<FROM>,<TO>:<CTAG>[:::CMDMDE=<CMDMDE>];

Input Example

ED-ROLL-STS1:CISCO:STS-1-1-1,STS-2-1-1:1:::CMDMDE=FRCD;

Input Parameters

Table 11-38 ED-ROLL-<MOD_PATH> Input Parameters 

Parameter and Values
Description

FROM

Source access identifier from the "CrossConnectId1" section. It is one of the termination points (legs) of the existing cross-connection. If the existing cross-connection is one-way, then this termination point (leg) should be the FROM-AID termination point. Otherwise, FROM is non-significant. FROM and TO should be entered as they are entered in the ENT-CRS command. You can issue RTRV-CRS command, and use the response for FROM and TO parameters

TO

Destination access identifier from the "CrossConnectId1" section. It is one of the termination points (legs) of the existing cross-connection. If the existing cross-connection is one-way, then this termination point (leg) should be the TO-AID termination point. Otherwise, the TO is non-significant. FROM and TO should be entered as they are entered in the ENT-CRS command. You can issue RTRV-CRS command, and use the response for FROM and TO parameters

CMDMDE

Command execution mode. Defaults to NORM.

Note CMDMDE can only go from NORM to FRCD (cannot go from FRCD to NORM). CMDMDE cannot be set to NORM using this command

Parameter type is CMDMDE—forces the system to execute a given command regardless of any standing conditions. Normal mode is the default behavior for all commands but you can specify FRCD to force the system to override a state where the command would normally be denied

FRCD

Force the system to override a state where the command would normally be denied

NORM

Execute the command normally. Do not override any conditions that might make the command fail


11.39  ED-SLV-WDMANS

Edit Span Loss Verification Wavelength Division Multiplexing Automatic Node Set Up

Usage Guidelines

Cisco ONS 15454

This command edits the expected span loss verification.

Category

DWDM

Security

Maintenance

Related Commands

DLT-LNK-<MOD2O>

DLT-LNKTERM

DLT-OSC

DLT-WLEN

ED-DWDM

ED-FFP-OCH

ED-LNK-<MOD2O>

ED-LNKTERM

ED-OCH

ED-OMS

ED-OSC

ED-OTS

ED-TRC-OCH

ED-WDMANS

ED-WLEN

ENT-LNK-<MOD2O>

ENT-LNKTERM

ENT-OSC

ENT-WLEN

OPR-LASER-OTS

OPR-PROTNSW-OCH

OPR-SLV-WDMANS

OPR-WDMANS

RLS-LASER-OTS

RLS-PROTNSW-OCH

RTRV-DWDM

RTRV-FFP-OCH

RTRV-LNK-<MOD2O>

RTRV-LNKTERM

RTRV-NE-WDMANS

RTRV-OCH

RTRV-OMS

RTRV-OSC

RTRV-OTS

RTRV-PROTNSW-OCH

RTRV-SLV-WDMANS

RTRV-TRC-OCH

RTRV-WDMANS

RTRV-WLEN


Input Format

ED-SLV-WDMANS:[<TID>]:<AID>:<CTAG>:::[HIGHSLVEXP=<HIGHSLVEXP>],
[LOWSLVEXP=<LOWSLVEXP>];

Input Example

ED-SLV-WDMANS:VA454-22:WDMANS-E:116:::HIGHSLVEXP=10.0,LOWSLVEXP=5.0;

Input Parameters

Table 11-39 ED-SLV-WDMANS Input Parameters 

Parameter and Values
Description

AID

Access identifier from the "WDMANS" section

HIGHSLVEXP

The high range value of the expected span loss verification. Float

LOWSLVEXP

The low range value of the expected span loss verification. Float


11.40  ED-SYNCN

Edit Synchronization

Usage Guidelines

Cisco ONS 15454, ONS 15327, ONS 15600, ONS 15310-CL

This command edits the synchronization reference list used to determine the sources for the NE's reference clock and the BITS output clock. For each clock, up to three synchronization sources might be specified (for example, PRIMARY, SECOND, THIRD).To view or edit the system timing mode, use the RTRV-NE-SYNCN or ED-NE-SYNCN commands.


Note To retrieve/set the timing mode, SSM message Set or Quality of RES information, use the RTRV-NE-SYNCN and ED-NE-SYNCN commands.


Category

Synchronization

Security

Provisioning

Related Commands

ED-BITS

ED-NE-SYNCN

OPR-SYNCNSW

REPT ALM BITS

REPT ALM SYNCN

REPT EVT BITS

REPT EVT SYNCN

RLS-SYNCNSW

RTRV-ALM-BITS

RTRV-ALM-SYNCN

RTRV-BITS

RTRV-COND-BITS

RTRV-COND-SYNCN

RTRV-NE-SYNCN

RTRV-SYNCN


Input Format

ED-SYNCN:[<TID>]:<AID>:<CTAG>:::[PRI=<PRI>],[SEC=<SEC>],[THIRD=<THIRD>][:];

Input Example

ED-SYNCN:BOYES:SYNC-NE:112:::PRI=INTERNAL,SEC=INTERNAL,THIRD=INTERNAL;

Input Parameters

Table 11-40 ED-SYNCN Input Parameters 

Parameter and Values
Description

AID

Access identifier from the "SYNC_REF" section

PRI

Primary reference of the synchronization from the "SYN_SRC" section

SEC

Secondary reference of the synchronization from the "SYN_SRC" section

THIRD

Third reference of the synchronization from the "SYN_SRC" section


11.41  ED-T1

Edit Digital Signal Facility

Usage Guidelines

Cisco ONS 15454, ONS 15327, ONS 15310-CL

This command edits the attributes related to a DS1/T1 port.


NoteThe T1 facilities on the ONS 15327 and ONS 15310-CL are on the XTC/15310-CL-CTX card.

This command is not allowed if the card is a protecting card.

If sending this command to edit TACC and any other attribute(s), and the port having the cross-connection, the (Parameters Not compatible) error message will be returned.

Editing TACC using an ED-xxx command is only allowed when there is no circuit/cross-connection on this port and the port/VT does not have a test access point (TAP or TACC number). Otherwise, an error message (for example, VT in Use) will be returned.

TACC creation will also be denied on the protect ports/cards.

AUTO-PROV is not supported.

The AISONLPBK and RETIME options are applicable only to the ONS 15310-CL and the DS2-E1-56 card on the ONS 15454.

The default values for all optional parameters are NE default values. These values might not be the current value for a parameter. Use the RTRV-XX commands to retrieve the current values.

The parameters: SYNCMAP, ADMSSM, VTMAP and INHFELPBK are only supported on the DS1-E1-56 card (ONS 15454).


Category

Ports

Security

Provisioning

Related Commands

DLT-<MOD1PAYLOAD>

DLT-FFP-<MOD2DWDMPAYLOAD>

DLT-FFP-<OCN_TYPE>

ED-<GIGE_TYPE>

ED-<MOD1FCPAYLOAD>

ED-<MOD1FICONPAYLOAD>

ED-<MOD2DWDMPAYLOAD>

ED-<OCN_TYPE>

ED-ALS

ED-DS1

ED-EC1

ED-FFP-<MOD2DWDMPAYLOAD>

ED-FFP-<OCN_TYPE>

ED-FSTE

ED-G1000

ED-GFP

ED-HDLC

ED-POS

ED-T3

ED-TRC-<MOD2DWDMPAYLOAD>

ED-TRC-<OCN_TYPE>

ENT-<MOD1PAYLOAD>

ENT-FFP-<MOD2DWDMPAYLOAD>

ENT-FFP-<OCN_TYPE>

INIT-REG-<MOD2>

OPR-ALS

OPR-LPBK-<MOD2>

OPR-PROTNSW-<MOD2DWDMPAYLOAD>

OPR-PROTNSW-<OCN_TYPE>

REPT PM <MOD2>

RLS-LPBK-<MOD2>

RLS-PROTNSW-<MOD2DWDMPAYLOAD>

RLS-PROTNSW-<OCN_TYPE>

RMV-<MOD2>

RST-<MOD2>

RTRV-<MOD1FCPAYLOAD>

RTRV-<MOD1FICONPAYLOAD>

RTRV-<MOD2DWDMPAYLOAD>

RTRV-<OCN_TYPE>

RTRV-10GIGE

RTRV-ALMTH-<MOD2>

RTRV-ALS

RTRV-DS1

RTRV-EC1

RTRV-FAC

RTRV-FFP-<MOD2DWDMPAYLOAD>

RTRV-FFP-<OCN_TYPE>

RTRV-FSTE RTRV-G1000

RTRV-GFP

RTRV-GIGE

RTRV-HDLC

RTRV-PM-<MOD2>

RTRV-PMSCHED-<MOD2>

RTRV-POS

RTRV-PROTNSW-<MOD2DWDMPAYLOAD>

RTRV-PROTNSW-<OCN_TYPE>

RTRV-T1

RTRV-T3

RTRV-TH-<MOD2>

RTRV-TRC-<MOD2DWDMPAYLOAD>

RTRV-TRC-<OCN_TYPE>

SCHED-PMREPT-<MOD2>

SET-ALMTH-<MOD2>

SET-TH-<MOD2>


Input Format

ED-T1:[<TID>]:<AID>:<CTAG>:::[LINECDE=<LINECDE>],[FMT=<FMT>],[LBO=<LBO>],
[TACC=<TACC>],[TAPTYPE=<TAPTYPE>],[SOAK=<SOAK>],[SFBER=<SFBER>],
[SDBER=<SDBER>],[SYNCMSG=<SYNCMSG>],[SENDDUS=<SENDDUS>],
[RETIME=<RETIME>],[NAME=<NAME>],[MODE=<MODE>],[SYNCMAP=<SYNCMAP>],
[ADMSSM=<ADMSSM>],[VTMAP=<VTMAP>],[INHFELPBK=<INHFELPBK>],
[AISONLPBK=<AISONLPBK>],[CMDMDE=<CMDMDE>],
[AISVONAIS=<AISVONAIS>]:[<PST>[,<SST>]];

Input Example

ED-T1:CISCO:FAC-2-1:1223:::LINECDE=AMI,FMT=ESF,LBO=0-131,TACC=8,
TAPTYPE=SINGLE,SOAK=10,SFBER=1E-4,SDBER=1E-6,SYNCMSG=Y,SENDDUS=Y,
RETIME=Y,NAME="T1PORT",MODE=FDL,SYNCMAP=ASYNC,ADMSSM=STU,
VTMAP=GR253,INHFELPBK=N,AISONLPBK=AIS_ON_LPBK_ALL,CMDMDE=CMDMDE,
AISVONAIS=Y:IS,AINS;

Input Parameters

Table 11-41 ED-T1 Input Parameters 

Parameter and Values
Description

AID

Access identifier from the "FACILITY" section

LINECDE

Line code

Parameter type is LINE_CODE—line code

AMI

Line code value is AMI

B8ZS

Line code value is B8ZS (bipolar with three-zero substitution)

FMT

Digital signal frame format

Parameter type is FRAME_FORMAT—frame format for a T1 port

D4

Frame format is D4

ESF

Frame format is ESF

UNFRAMED

Frame format is unframed

LBO

Line buildout settings. Integer

Parameter type is LINE_BUILDOUT—Line buildout

0-131

Line buildout range is 0-131

132-262

Line buildout range is 132-262

263-393

Line buildout range is 263-393

394-524

Line buildout range is 394-524

525-655

Line buildout range is 525-655

TACC

TAP number within a range of 0 to 999. Indicates whether the digroup being provisioned is to be used as a test access digroup. When TACC is 0 (zero), the TAP is deleted. Default is N. Integer

TAPTYPE

TAP type. Defaults to DUAL

Parameter type is TAPTYPE—test access point type

DUAL

Dual FAD

SINGLE

Single FAD

SOAK

OOS-AINS to IS transition soak time as measured in 15-minute intervals. A value of 4 equals a soak time of 1 hour. The allowable range is 0 to 192 intervals (maximum of 48 hours). Integer

SFBER

The port signal failure threshold

Parameter type is SF_BER—the threshold for declaring signal failure on a facility or path

1E-3

SFBER is 1E-3

1E-4

SFBER is 1E-4

1E-5

SFBER is 1E-5

SDBER

Port signal degrade threshold

Parameter type is SD_BER—the threshold for declaring signal degrade on a facility or path

1E-5

SDBER is 1E-5

1E-6

SDBER is 1E-6

1E-7

SDBER is 1E-7

1E-8

SDBER is 1E-8

1E-9

SDBER is 1E-9

SYNCMSG

Synchronization status messaging is enabled or disabled on the T1 facility.

Note For ONS 15310-CL, SYNCMSG defaults to N. SYNCMSG is not supported on the ONS 15454 or ONS 15327

Parameter type is YES_NO—whether the user's password is about to expire, the user is logged into the NE, or the user is locked out of the NE

NO

No

YES

Yes

SENDDUS

The facility will send the DUS (Don't use for Synchronization) value as the sync status message for that facility

Note For ONS 15310-CL, SENDDUS is optional and defaults to N. SENDDUS is not supported on the ONS 15454 or ONS 15327

Parameter type is YES_NO—whether the user's password is about to expire, the user is logged into the NE, or the user is locked out of the NE

NO

No

YES

Yes

RETIME

Indicates if retiming is needed.

Note For ONS 15310-CL, RETIME is optional and defaults to N. RETIME is not supported on the ONS 15454 or ONS 15327

Parameter type is YES_NO—whether the user's password is about to expire, the user is logged into the NE, or the user is locked out of the NE

NO

No

YES

Yes

NAME

Name. String

MODE

Mode. Default value is FDL

Parameter type is DS1MODE—the DS1 path mode of the DS3XM-12 card

ATT

Indicates the DS1 path of the DS3XM-12 is in AT&T 54016 mode

FDL

Indicates the DS1 path of the DS3XM-12 is in FDL T1-403 mode

SYNCMAP

The synchronous mapping for the DS1 facility. Defaults to ASYNC. Only supported on ONS 15454.

Parameter type is SYNCMAP—synchronous mapping type

ASYNC

Asynchronous

BYTE

Mapping in byte

JBYTE

Mapping in jbyte

ADMSSM

The administrative synchronization status message. Only supported on the ONS 15454. Defaults to STU

Parameter type is SYNC_CLOCK_REF_QUALITY_LEVEL—clock source quality level

DUS

Do Not Use For Synchronization

PRS

Primary Reference Source, Stratum 1 Traceable

RES

Reserved For Network Synchronization Use

SMC

SONET Minimum Clock Traceable

ST2

Stratum 2 Traceable

ST3

Stratum 3 Traceable

ST3E

Stratum 3E Traceable

ST4

Stratum 4 Traceable

STU

Synchronized, Traceability Unknown

TNC

Transit Node Clock (2nd Generation Only)

VTMAP

The port to VT mapping type for that particular STS. Only supported on ONS 15454. Defaults to GR253

Parameter type is VTMAP—VT mapping

GR253

Mapping based on GR253

INDUSTRY

Mapping based on industry standard

INHFELPBK

Indicates whether far end loopbacks are inhibited on the facility. Only supported on ONS 15454. Defaults to N

Parameter type is ON_OFF—disable/enable an attribute

N

Disable an attribute

Y

Enable an attribute

AISONLPBK

Defaults to AIS_ON_LPBK_ALL

Parameter type is AIS_ON_LPBK—Indicates if AIS is sent on a loopback

AIS_ONLPBK_FACILITY

AIS is sent on facility loopbacks

AIS_ON_LPBK_ALL

AIS is sent on all loopbacks

AIS_ON_LPBK_OFF

AIS is not sent on loopbacks

AIS_ON_LPBK_TERMINAL

AIS is sent on terminal loopbacks

CMDMDE

Command mode

Parameter type is CMDMDE—forces the system to execute a given command regardless of any standing conditions. Normal mode is the default behavior for all commands but you can specify FRCD to force the system to override a state where the command would normally be denied

FRCD

Force the system to override a state where the command would normally be denied

NORM

Execute the command normally. Do not override any conditions that might make the command fail

AISVONAIS

Defaults to N

Parameter type is ON_OFF—disable/enable an attribute

N

Disable an attribute

Y

Enable an attribute

PST

Primary state

Parameter type is PST—indicates the current overall service condition of an entity

IS

In service

OOS

Out of service

SST

Secondary state

Parameter type is SST—provides additional information pertaining to PST and PSTQ

AINS

Automatic in service

DSBLD

Disabled

LPBK

Loopback

MEA

Mismatch of equipment and attributes

MT

Maintenance mode

OOG

Out of group

SWDL

Software downloading

UAS

Unassigned

UEQ

Unequipped


11.42  ED-T3

Edit Digital Signal Facility

Usage Guidelines

Cisco ONS 15454, ONS 15327, ONS 15310-CL

This command edits the attributes related to a DS3/T3 port and DS3I card.


NoteThe T3 facilities on the ONS 15327 and ONS 15310-CL are on the XTC/15310-CL-CTX card.

This command is not allowed if the card is a protecting card.

Both FMT and Line code are not supported for T3/DS3 facility. They are supported on both the DS3XM and DS3E card. The unframed value of the framing format is only supported on the DS3E facility.

If sending this command to edit TACC and any other attribute(s), and the port having the cross-connection or the port/VT has a test access point (TAP or TACC number), the (Parameters Not compatible) error message will be returned.

Editing TACC using an ED-xxx command is only allowed when there is no circuit/cross-connection on the port and the port/VT does not have a test access point (TAP or TACC number). Otherwise, an error message (VT in Use) will be returned.

TACC creation will also be denied on the protect ports/cards.

Automatic application of loopbacks originating from the far end can be initiated on the T3 ports of a DS3E, DS3NE, or DS3XM card.

CTC can set the FMT attribute of a DS3(N)E line to AUTOPROVISION to set the framing based on the framing that is coming in. The result is the FMT field being blanked out for a few seconds or blanked out indefinitely for a preprovisioned DS3(N)E card in CTC. The AUTOPROVISION is not considered a valid DS3 framing type. It is only used to trigger an autosense and subsequent auto provisioning of a valid DS3 framing type (unframed, M13, C-BIT). TL1 does not have the AUTOPROVISION mode. TL1 maps/returns the AUTOPROVISION mode to the unframed framing type.

For the DS3XM-12 card, the DS3/T3 configurable attributes (PM, TH, alarm, etc.) only apply on the ported ports (1-12) and the DS3-mapped (even) portless ports in xxx-xxx-T3 commands. If you attempt to provision or retrieve DS3/T3 attributes on the VT-mapped (odd) portless port in xxx-xxx-T3 commands, an error message will be returned.

For the DS3XM-12 card, if the admin state is already set for a portless port the state setting operation over its associated ported port is an invalid operation.

The test set physical connection set up through ED-T3/DS1/STS1/VT1 of the DS3XM-12 card is only allowed on the physical front ports (PORTED ports, ports 1-12), which are the monitoring ports.

The monitoring test access ports follow the common rules for the other cards. For example, ED-T3 on port 2 (FAC-6-2) with a TACC number (8), the next port, port 3 (FAC-6-3) is used as the monitoring point also. The RTRV-T3 on both port-2 and port-3 return the same TACC number (8) being used to monitor the cross-connection end (A-B). The last port (port 12) is not allowed to set-up a physical connection with the test set because there is no next available port to be the monitoring port.

The TACC disconnection (DISC-TACC) command and the test access mode change (CHG-TACC) command follow the same requirement as in note 11a. above, but applied on the ported ports of the DS3XM-12 card.

The test access connection set-up (CONN-TACC) command has monitored points which can be portless ports. This command is applied on both ported and portless ports of the DS3XM-12 card.

If the entity has a TACC connection, the entity is not allowed to have ported or portless STS/VT cross-connection (or circuit) provisioning on the DS3XM-12 card.

ED-T3 cannot be used to create TAPs on the DS3I card on the SONET platform because the DS3I card only supports STS3C TAPs.

You cannot use this command to change the default provisioning on Slots 3 and 15 for the DS3-EC1-48 card.

The AISONLPBK is only applicable to the ONS 15310-CL.

The default values for all optional parameters are NE default values. These values might not be the current value for a parameter. Use the RTRV-XX command to retrieve current default values.


Category

Ports

Security

Provisioning

Related Commands

DLT-<MOD1PAYLOAD>

DLT-FFP-<MOD2DWDMPAYLOAD>

DLT-FFP-<OCN_TYPE>

ED-<GIGE_TYPE>

ED-<MOD1FCPAYLOAD>

ED-<MOD1FICONPAYLOAD>

ED-<MOD2DWDMPAYLOAD>

ED-<OCN_TYPE>

ED-ALS

ED-DS1

ED-EC1

ED-FFP-<MOD2DWDMPAYLOAD>

ED-FFP-<OCN_TYPE>

ED-FSTE

ED-G1000

ED-GFP

ED-HDLC

ED-POS

ED-T1

ED-TRC-<MOD2DWDMPAYLOAD>

ED-TRC-<OCN_TYPE>

ENT-<MOD1PAYLOAD>

ENT-FFP-<MOD2DWDMPAYLOAD>

ENT-FFP-<OCN_TYPE>

INIT-REG-<MOD2>

OPR-ALS

OPR-LPBK-<MOD2>

OPR-PROTNSW-<MOD2DWDMPAYLOAD>

OPR-PROTNSW-<OCN_TYPE>

REPT PM <MOD2>

RLS-LPBK-<MOD2>

RLS-PROTNSW-<MOD2DWDMPAYLOAD>

RLS-PROTNSW-<OCN_TYPE>

RMV-<MOD2>

RST-<MOD2>

RTRV-<MOD1FCPAYLOAD>

RTRV-<MOD1FICONPAYLOAD>

RTRV-<MOD2DWDMPAYLOAD>

RTRV-<OCN_TYPE>

RTRV-10GIGE

RTRV-ALMTH-<MOD2>

RTRV-ALS

RTRV-DS1

RTRV-EC1

RTRV-FAC

RTRV-FFP-<MOD2DWDMPAYLOAD>

RTRV-FFP-<OCN_TYPE>

RTRV-FSTE

RTRV-G1000

RTRV-GFP

RTRV-GIGE

RTRV-HDLC

RTRV-PM-<MOD2>

RTRV-PMSCHED-<MOD2>

RTRV-POS

RTRV-PROTNSW-<MOD2DWDMPAYLOAD>

RTRV-PROTNSW-<OCN_TYPE>

RTRV-T1

RTRV-T3

RTRV-TH-<MOD2>

RTRV-TRC-<MOD2DWDMPAYLOAD>

RTRV-TRC-<OCN_TYPE>

SCHED-PMREPT-<MOD2>

SET-ALMTH-<MOD2>

SET-TH-<MOD2>


Input Format

ED-T3:[<TID>]:<AID>:<CTAG>:::[FMT=<FMT>],[LINECDE=<LINECDE>],[LBO=<LBO>],
[INHFELPBK=<INHFELPBK>],[TACC=<TACC>],[TAPTYPE=<TAPTYPE>],[SOAK=<SOAK>],
[SFBER=<SFBER>],[SDBER=<SDBER>],[NAME=<NAME>],[AISONLPBK=<AISONLPBK>],
[CMDMDE=<CMDMDE>]:[<PST>[,<SST>]];

Input Example

ED-T3:CISCO:FAC-1-2:123:::FMT=C-BIT,LINECDE=B3ZS,LBO=0-225,INHFELPBK=N,
TACC=8,TAPTYPE=SINGLE,SOAK=10,SFBER=1E-4,SDBER=1E-6,NAME="T3 PORT",
AISONLPBK=AIS_ON_LPBK_ALL,CMDMDE=CMDMDE:IS,AINS;

Input Parameters

Table 11-42 ED-T3 Input Parameters 

Parameter and Values
Description

AID

Access identifier from the "FACILITY" section

FMT

Digital signal frame format. The unframed value of the framing format is only supported for the DS3E card

Parameter type is DS_LINE_TYPE—DS123 line type

C-BIT

C-BIT line type applies to the DS3XM and DS3E cards

M13

M13 line type applies to the DS3XM and DS3E cards

UNFRAMED

Line type is unframed. The old DS3 (L3M) and DS3CR cards can only run in unframed mode

LINECDE

Line code

Parameter type is DS_LINE_CODE—DS123 line code

B3ZS

Bipolar with three-zero substitution

LBO

Line build out settings. Integer

Parameter type is E_LBO—electrical signal line buildout

0-225

Electrical signal line buildout range is 1-225

226-450

Electrical signal line buildout range is 226-450

INHFELPBK

Far end loopback inhibition attribute of the port. If it is Y, the automatic far end loopbacks are inhibited. It is either on or off. The system default is N. Optional

Parameter type is ON_OFF—disable or enable an attribute

N

Disable an attribute

Y

Enable an attribute

TACC

TAP number within a range of 0 to 999. Indicates whether the digroup being provisioned is to be used as a test access digroup. When TACC is 0 (zero), the TAP is deleted. Default is N. Integer

TAPTYPE

TAP type. Defaults to DUAL

Parameter type is TAPTYPE—test access point type

DUAL

Dual FAD

SINGLE

Single FAD

SOAK

OOS-AINS to IS transition soak time as measured in 15-minute intervals. A value of 4 equals a soak time of 1 hour. The allowable range is 0 to 192 intervals (maximum of 48 hours). Integer

SFBER

The port signal failure threshold

Parameter type is SF_BER—the threshold for declaring signal failure on a facility or path

1E-3

SFBER is 1E-3

1E-4

SFBER is 1E-4

1E-5

SFBER is 1E-5

SDBER

Port signal degrade threshold

Parameter type is SD_BER—the threshold for declaring signal degrade on a facility or path

1E-5

SDBER is 1E-5

1E-6

SDBER is 1E-6

1E-7

SDBER is 1E-7

1E-8

SDBER is 1E-8

1E-9

SDBER is 1E-9

NAME

Name. String

AISONLPBK

Defaults to AIS_ON_LPBK_ALL

Parameter type is AIS_ON_LPBK—Indicates if AIS is sent on a loopback

AIS_ONLPBK_FACILITY

AIS is sent on facility loopbacks

AIS_ON_LPBK_ALL

AIS is sent on all loopbacks

AIS_ON_LPBK_OFF

AIS is not sent on loopbacks

AIS_ON_LPBK_TERMINAL

AIS is sent on terminal loopbacks

CMDMDE

Command mode

Parameter type is CMDMDE—forces the system to execute a given command regardless of any standing conditions. Normal mode is the default behavior for all commands but you can specify FRCD to force the system to override a state where the command would normally be denied

FRCD

Force the system to override a state where the command would normally be denied

NORM

Execute the command normally. Do not override any conditions that might make the command fail

PST

Primary state

Parameter type is PST—indicates the current overall service condition of an entity

IS

In service

OOS

Out of service

SST

Secondary state

Parameter type is SST—provides additional information pertaining to PST and PSTQ

AINS

Automatic in service

DSBLD

Disabled

LPBK

Loopback

MEA

Mismatch of equipment and attributes

MT

Maintenance mode

OOG

Out of group

SWDL

Software downloading

UAS

Unassigned

UEQ

Unequipped


11.43  ED-TRAPTABLE

Edit Trap Table

Usage Guidelines

Cisco ONS 15454, ONS 15327, ONS 15600, ONS 15310-CL

This command edits a trap destination entry identified by a specific trap destination address.

Category

System

Security

Provisioning

Related Commands

ACT-USER

ALW-MSG-ALL

ALW-MSG-DBCHG

ALW-MSG-SECU

DLT-TRAPTABLE

ED-DAT

ED-NE-GEN

ED-NE-PATH

ED-NE-SYNCN

ENT-TRAPTABLE

INH-MSG-ALL

INH-MSG-DBCHG

INH-MSG-SECU

INIT-SYS

RTRV-HDR

RTRV-INV

RTRV-NE-GEN

RTRV-NE-IPMAP

RTRV-NE-PATH

RTRV-NE-SYNCN

RTRV-NE-WDMANS

RTRV-TOD

RTRV-TRAPTABLE

SET-TOD


Input Format

ED-TRAPTABLE:[<TID>]:<AID>:<CTAG>:::COMMUNITY=<COMMUNITY>,
[TRAPPORT=<TRAPPORT>],[TRAPVER=<TRAPVER>];

Input Example

ED-TRAPTABLE::1.2.3.4:1:::COMMUNITY="PUBLIC",TRAPPORT=162,TRAPVER=SNMPV1;

Input Parameters

Table 11-43 ED-TRAPTABLE Input Parameters 

Parameter and Values
Description

AID

Access identifier from the "IPADDR" section. IP address identifying the trap destination

COMMUNITY

Community name associated to the trap destination. Maximum of 32 characters. String

TRAPPORT

UDP port number associated with the trap destination. Default to 162. Integer

TRAPVER

SNMP version number. Defaults to SNMPv1

Parameter type is SNMP_VERSION—SNMP version

SNMPV1

SNMP version 1 (default)

SNMPV2

SNMP version 2


11.44  ED-TRC-OCH

Edit Trace Optical Channel Facility

Usage Guidelines

Cisco ONS 15454

The command edits trace-related optical channel facilities.

Refer to the Cisco ONS SONET TL1 Reference Guide for specific card provisioning rules.

Category

DWDM

Security

Provisioning

Related Commands

DLT-LNK-<MOD2O>

DLT-LNKTERM

DLT-OSC

DLT-WLEN

ED-DWDM

ED-FFP-OCH

ED-LNK-<MOD2O>

ED-LNKTERM

ED-OCH

ED-OMS

ED-OSC

ED-OTS

ED-WDMANS

ED-WLEN

ENT-LNK-<MOD2O>

ENT-LNKTERM

ENT-OSC

ENT-WLEN

OPR-LASER-OTS

OPR-PROTNSW-OCH

OPR-WDMANS

RLS-LASER-OTS

RLS-PROTNSW-OCH

RTRV-DWDM

RTRV-FFP-OCH

RTRV-LNK-<MOD2O>

RTRV-LNKTERM

RTRV-NE-WDMANS

RTRV-OCH

RTRV-OMS

RTRV-OSC

RTRV-OTS

RTRV-PROTNSW-OCH

RTRV-TRC-OCH

RTRV-WDMANS

RTRV-WLEN


Input Format

ED-TRC-OCH:[<TID>]:<SRC>:<CTAG>:::[EXPTRC=<EXPTRC>],[TRC=<TRC>],
[TRCMODE=<TRCMODE>],[TRCLEVEL=<TRCLEVEL>],[TRCFORMAT=<TRCFORMAT>][:];

Input Example

ED-TRC-OCH:CISCO:CHAN-6-2:10:::EXPTRC="AAA",TRC="AAA",TRCMODE=MAN,
TRCLEVEL=TTI-PM,TRCFORMAT=64-BYTE;

Input Parameters

Table 11-44 ED-TRC-OCH Input Parameters 

Parameter and Values
Description

SRC

Source access identifier from the "CHANNEL" section

EXPTRC

Expected path trace content. Indicates the expected path trace message (J1) contents. EXPTRC is any 64-character ASCII string, including the terminating CR (carriage return) and LF (line feed). A null value is equivalent to ALL. String

TRC

The path trace message to be transmitted. The trace byte continuously transmits a 64 byte, fixed length ASCII string, one byte at a time. A null value defaults to the NE transmitting 62 null characters (Hex 00) and CR and LF. A null value is equivalent to ALL

TRCMODE

Trace mode. Defaults to the OFF mode

Parameter type is TRCMODE—trace mode

AUTO

Use the previously received path trace string as the expected string. Not applicable to MXP/TXP cards

AUTO-NO-AIS

Use the previously received path trace string as the expected string and do not turn on AIS and RDI if TIMP is detected

MAN

Use the provisioned expected string as the expected string

MAN-NO-AIS

Use the provisioned expected string as the expected string and do not turn on AIS and RDI if TIMP is detected

OFF

Turn off path trace capability. Nothing will be reported

TRCLEVEL

The trace level to be managed. String

TRCFORMAT

Trace message size

Parameter type is TRCFORMAT—trace format

1-BYTE

1 byte trace message

16-BYTE

16 byte trace message

64-BYTE

64 byte trace message

Y

Enable an attribute


11.45  ED-USER-SECU

Edit User Security

Usage Guidelines

Cisco ONS 15454, ONS 15327, ONS 15600, ONS 15310-CL

This command edits a user's privileges, password, or ID. Only a Superuser might perform this operation. Privilege levels are described in the ENT-USER-SECU command.


NotePasswords are masked for the following security commands: ACT-USER, ED-PID, ENT-USER-SECU and ED-USER-SECU. Access to a TL1 session by any means will have the password masked. The CTC Request History and Message Log will also show the masked commands. When a password-masked command is reissued by double-clicking the command from CTC Request History, the password will still be masked in the CTC Request History and Message Log. The actual password that was previously issued will be sent to the NE. To use a former command as a template only, single-click the command in CTC Request History. The command will be placed in the Command Request text box, where you can edit the appropriate fields prior to reissuing it.

Although the CTC allows both <UID> and <PID> of up to 20 characters, the CTC-entered users (<UID>, <PID>) are not valid TL1 users (for example, if issuing an ACT-USER command and using the CTC-entered <UID> that is greater than 10 characters long, TL1 will respond with DENY.

For the ED-USER-SECU command;

ED-USER-SECU:[TID]:<UID>:[CTAG]::[<NEWUID>],[<NEWPID>],,[<UAP>]:;

If the <NEWPID> is specified, the syntax is checked.

The syntax of <UID> is not checked.

Old users can change their password without changing their userid, but the new password must meet the new requirements.

The <NEWPID> is required when changing the <USERID>.

In this release, when <NEWUID> is specified, <NEWPID> (and the <UAP>) become mandatory, but it is possible to change a USERID without changing the password by providing the same password. You cannot keep your old password if the old password does not meet the new syntax requirements. For example:

<USERID> = CISCO2345
<PASSWORD>=CISCO#234 /*PASSWORD ALREADY MEETS REQUIREMENTS*/

ED-USER-SECU::CISCO2345:1::CISCO3456,CISCO#234,,PROV;

TCCP 1970-01-02 13:15:35 M 1 COMPLD ;

<NEWUSERID> = CISCO60
<USERID> = CISCO40 <PASSWORD>=CISCO40 /*PASSWORD DOES NOT MEET REQUIREMENTS*/

ED-USER-SECU::CISCO40:1::CISCO60,CISCO40,,PROV;

BRONCOS4 1970-01-02 13:14:24 M 1 DENY IIFM /* INVALID PASSWORD */ ;

The ED-USER-SECU command should be used to change the default password for the CISCO15 default superuser.

The ED-PID command cannot be used to change the empty password to a valid password.


Category

Security

Security

Superuser

Related Commands

ACT-USER

ALW-MSG-SECU

ALW-USER-SECU

CANC

CANC-USER

CANC-USER-SECU

CLR-COND-SECU

DLT-USER-SECU

ED-CMD-SECU

ED-PID

ENT-USER-SECU

INH-MSG-SECU

INH-USER-SECU

REPT ALM SECU

REPT EVT SECU

REPT EVT SESSION

RTRV-CMD-SECU

RTRV-DFLT-SECU

RTRV-USER-SECU

SET-ATTR-SECUDFLT


Input Format

ED-USER-SECU:[<TID>]:<UID>:<CTAG>::[<NEWUID>],[<NEWPID>],,[<UAP>][:];

Input Example

ED-USER-SECU:PETALUMA:CISCO15:123::NEWUID,NEWPID,,MAINT;

Input Parameters

Table 11-45 ED-USER-SECU Input Parameters 

Parameter and Values
Description

UID

User's identifier. Minimum UID is 6 characters. Maximum UID is 10 characters. String

NEWUID

User's new identifier. Minimum UID is 6 characters. Maximum UID is 10 characters. String

NEWPID

User's new password. Minimum UID is 6 characters. Maximum UID is 10 characters. String

UAP

User's access privilege

Parameter type is PRIVILEGE—security level

MAINT

Maintenance security level. 60 minutes of idle time

PROV

Provision security level. 30 minutes of idle time

RTRV

Retrieve security level. Unlimited idle time

SUPER

Superuser security level. 15 minutes of idle time


11.46  ED-VCG

Edit Virtual Concatenated Group

Usage Guidelines

Cisco ONS 15454, ONS 15310-CL

This command edits the attributes of a VCG.

Category

VCAT

Security

Provisioning

Related Commands

DLT-VCG

ENT-VCG

RTRV-VCG


Input Format

ED-VCG:[<TID>]:<SRC>:<CTAG>:::[TXCOUNT=<TXCOUNT>],[NAME=<NAME>];

Input Example

ED-VCG:NODE1:FAC-1-1:1234:::TXCOUNT=7,NAME="VCG2";

Input Parameters

Table 11-46 ED-VCG Input Parameters 

Parameter and Values
Description

SRC

Source access identifier from the "FACILITY" section

TXCOUNT

Number of members in the Tx direction. For ML1000-2 and ML100T-12 cards the only valid value is 2. For the FC_MR-4 card the only valid value is 8. Integer

NAME

Name of the VCAT group. Maximum length is 64 characters. String.


11.47  ED-WDMANS

Edit Wavelength Division Multiplexing Automatic Node Set Up

Usage Guidelines

Cisco ONS 15454

This command edits the optical node set-up application (AONS) attributes.

Category

DWDM

Security

Maintenance

Related Commands

DLT-LNK-<MOD2O>

DLT-LNKTERM

DLT-OSC

DLT-WLEN

ED-DWDM

ED-FFP-OCH

ED-LNK-<MOD2O>

ED-LNKTERM

ED-OCH

ED-OMS

ED-OSC

ED-OTS

ED-TRC-OCH

ED-WLEN

ENT-LNK-<MOD2O>

ENT-LNKTERM

ENT-OSC

ENT-WLEN

OPR-LASER-OTS

OPR-PROTNSW-OCH

OPR-WDMANS

RLS-LASER-OTS

RLS-PROTNSW-OCH

RTRV-DWDM

RTRV-FFP-OCH

RTRV-LNK-<MOD2O>

RTRV-LNKTERM

RTRV-NE-WDMANS

RTRV-OCH

RTRV-OMS

RTRV-OSC

RTRV-OTS

RTRV-PROTNSW-OCH

RTRV-TRC-OCH

RTRV-WDMANS

RTRV-WLEN


Input Format

ED-WDMANS:[<TID>]:<AID>:<CTAG>:::[POWER-IN=<POWERIN>],
[POWER-OUT=<POWEROUT>],[POWER-EXP=<POWEREXP>],[NTWTYPE=<NTWTYPE>];

Input Example

ED-WDMANS:PENNGROVE:WDMANS-W:114:::POWERIN=10.0,POWEROUT=10.0,|
POWEREXP=10.0,NTWTYPE=METRO-CORE;

Input Parameters

Table 11-47 ED-WDMANS Input Parameters 

Parameter and Values
Description

AID

Access identifier from the "WDMANS" section

POWERIN

Input power for OADM section or Mux/Demux for terminal nodes. Float

POWEROUT

Output power for OADM section or Mux/Demux for terminal nodes. Float

POWEREXP

Express power for OADM section. Float

NTWTYPE

Network type where a DWDM node is installed

Parameter type is DWDM_RING_TYPE—network type where NE is installed

METRO-ACCESS

The network where a DWDM node is installed is a metro access network

METRO-CORE

The network where a DWDM node is installed is a metro core network

NONE

A node that does not have a standard DWDM configuration


11.48  ED-WLEN

Edit Wavelength

Usage Guidelines

Cisco ONS 15454

This command edits WLEN (wavelength) provisioning.


NoteThe fields after CTAG (trailing colons) are optional.

This command does not support multiple editing of WLEN provisioning.

The maximum length of the SIZE parameter is 48 characters.

CKTID is a string of ASCII characters. The maximum length of a CKTID can be 48. If CKTID is EMPTY or NULL this field will not appear.


Category

DWDM

Security

Provisioning

Related Commands

DLT-LNK-<MOD2O>

DLT-LNKTERM

DLT-OSC

DLT-WDMANS

ED-DWDM

ED-FFP-OCH

ED-LNK-<MOD2O>

ED-LNKTERM

ED-OCH

ED-OMS

ED-OSC

ED-OTS

ED-TRC-OCH

ED-WLEN

ENT-LNK-<MOD2O>

ENT-LNKTERM

ENT-OSC

ENT-WLEN

OPR-LASER-OTS

OPR-PROTNSW-OCH

OPR-WDMANS

RLS-LASER-OTS

RLS-PROTNSW-OCH

RTRV-DWDM

RTRV-FFP-OCH

RTRV-LNK-<MOD2O>

RTRV-LNKTERM

RTRV-NE-WDMANS

RTRV-OCH

RTRV-OMS

RTRV-OSC

RTRV-OTS

RTRV-PROTNSW-OCH

RTRV-TRC-OCH

RTRV-WDMANS

RTRV-WLEN


Input Format

ED-WLEN:[<TID>]:<AID>:<CTAG>:::[SIZE=<SIZE>],[CKTID=<CKTID>],
[CMDMDE=<CMDMDE>]:[<PST>[,<SST>]];

Input Example

ED-WLEN:PENNGROVE:WLEN-W-ADD-1530.33:1:::SIZE=NOT-SPEC,CKTID=CKTID,
CMDMDE=CMDMDE:IS,AINS;

Input Parameters

Table 11-48 ED-WLEN Input Parameters 

Parameter and Values
Description

AID

Access identifier from the "WLEN" section

SIZE

Size of the switching network. Defaults to NOT-SPEC

Parameter type is CIRCUIT_SIZE—the DWDM circuit size used on a wavelength

10G-FEC

The circuit size is 10 Gbps with FEC

10G-NO-FEC

The circuit size is10 Gbps without FEC

2G5-FEC

The circuit size is 2.5 Gbps with FEC

2G5-NO-FEC

The circuit size is 2.5 Gbps without FEC

MULTI-RATE

The circuit size is supports multirate

NOT-SPEC

The circuit size is not equipment specific

CKTID

Circuit ID. String. Defaults to " " (empty string)

CMDMDE

Command execution mode, forced or normal. FRCD is only applicable if the PST=OOS and SST=DSBLD

Parameter type is CMDMDE—forces the system to execute a given command regardless of any standing conditions. Normal mode is the default behavior for all commands but you can specify FRCD to force the system to override a state where the command would normally be denied

FRCD

Force the system to override a state where the command would normally be denied

NORM

Execute the command normally. Do not override any conditions that might make the command fail

PST

Primary state

Parameter type is PST—indicates the current overall service condition of an entity

IS

In service

OOS

Out of service

SST

Secondary state

Parameter type is SST—provides additional information pertaining to PST and PSTQ

AINS

Automatic in service

DSBLD

Disabled

LPBK

Loopback

MEA

Mismatch of equipment and attributes

MT

Maintenance mode

OOG

Out of group

SWDL

Software downloading

UAS

Unassigned

UEQ

Unequipped



hometocprevnextglossaryfeedbacksearchhelp

Posted: Mon Sep 3 11:18:29 PDT 2007
All contents are Copyright © 1992--2007 Cisco Systems, Inc. All rights reserved.
Important Notices and Privacy Statement.