Note The terms "Unidirectional Path Switched Ring" and "UPSR" may appear in Cisco literature. These terms do not refer to using Cisco ONS 15xxx products in a unidirectional path switched ring configuration. Rather, these terms, as well as "Path Protected Mesh Network" and "PPMN," refer generally to Cisco's path protection feature, which may be used in any topological network configuration. Cisco does not recommend using its path protection feature in any particular topological network configuration.
This chapter provides ED (edit) commands for the Cisco ONS 15454, ONS 15327, ONS 15600 and ONS 15310-CL.
11.1 ED-<GIGE_TYPE>
Edit (10GIGE, GIGE)
Usage Guidelines
Cisco ONS 15454, ONS 15600
This command edits Ethernet facility attributes.
See Table 27-1 for supported modifiers by platform.
CategoryPorts
SecurityProvisioning
Related Commands
Input FormatED-<GIGE_TYPE>:[<TID>]:<AID>:<CTAG>:::[NAME=<NAME>],[MACADDR=<MACADDR>],
[CMDMDE=<CMDMDE>],[FREQ=<FREQ>],[LOSSB=<LOSSB>]:[<PST>[,<SST>]];Input ExampleED-GIGE:CISCO:FAC-1-1:123:::NAME="GIGE PORT",
MACADDR=00-0E-AA-BB-CC-FF,CMDMDE=CMDMDE,FREQ=1550,LOSSB=SX:IS,AINS;Input Parameters
Table 11-1 ED-<GIGE_TYPE> Input Parameters
Parameter and Values DescriptionAID
Access identifier from the "FACILITY" section
NAME
Port name. String. Defaults to NULL. Maximum length is 32 characters
MACADDR
String. Defaults to NULL. Maximum length is 18 characters
CMDMDE
Command execution mode. NORM for normal (default) and FRCD for forced. FRCD will override any safeguards that normally reject a request to delete an in service resource
Parameter type is CMDMDE—forces the system to execute a given command regardless of any standing conditions. Normal mode is the default behavior for all commands but you can specify FRCD to force the system to override a state where the command would normally be denied
•FRCD
Force the system to override a state where the command would normally be denied
•NORM
Execute the command normally. Do not override any conditions that might make the command fail
FREQ
Parameter type is OPTICAL-WLEN—optical wavelength
•1530.33
Wavelength 1
•1531.12
Wavelength 2
•1531.90
Wavelength 3
•1532.68
Wavelength 4
•1534.25
Wavelength 5
•1535.04
Wavelength 6
•1535.82
Wavelength 7
•1536.61
Wavelength 8
•1538.19
Wavelength 9
•1538.98
Wavelength 10
•1539.77
Wavelength 11
•1540.56
Wavelength 12
•1542.14
Wavelength 13
•1542.94
Wavelength 14
•1543.73
Wavelength 15
•1544.53
Wavelength 16
•1546.12
Wavelength 17
•1546.92
Wavelength 18
•1547.72
Wavelength 19
•1548.51
Wavelength 20
•1550.12
Wavelength 21
•1550.92
Wavelength 22
•1551.72
Wavelength 23
•1552.52
Wavelength 24
•1554.13
Wavelength 25
•1554.94
Wavelength 26
•1555.75
Wavelength 27
•1556.55
Wavelength 28
•1558.17
Wavelength 29
•1558.98
Wavelength 30
•1559.79
Wavelength 31
•1560.61
Wavelength 32
•USE-TWL1
Use Tunable Wavelength 1
LOSSB
Parameter type is REACH—reach values
•AUTOPROV
Autoprovisioning
•CX
Reach CX
•DX
Reach DX
•HX
Reach HX
•I1
Reach I1
•IR-1
Reach IR-1
•IR-2
Reach IR-2
•L1
Reach L1
•L2
Reach L2
•L3
Reach L3
•LR-1
Reach LR-1
•LR-2
Reach LR-2
•LR-3
Reach LR-3
•LX
Reach LX
•S1
Reach S1
•S2
Reach S2
•SR
Reach SR
•SR-1
Reach SR-1
•SX
Reach SX
•T
Reach T
•VX
Reach VX
•ZX
Reach ZX
PST
Primary state
Parameter type is PST—indicates the current overall service condition of an entity
•IS
In service
•OOS
Out of service
SST
Secondary state
Parameter type is SST—provides additional information pertaining to PST and PSTQ
•AINS
Automatic in service
•DSBLD
Disabled
•LPBK
Loopback
•MEA
Mismatch of equipment and attributes
•MT
Maintenance mode
•OOG
Out of group
•SWDL
Software downloading
•UAS
Unassigned
•UEQ
Unequipped
11.2 ED-<MOD1FCPAYLOAD>
Edit (1GFC, 2GFC)
Usage Guidelines
Cisco ONS 15454
See Table 27-1 for supported modifiers by platform.
This command edits the attributes related to the Fibre Channel (FC) facility. The state IS,AINS is not supported on the FC port.
Note•The port parameters: VIZ, LINKRCVRY, DISTEXTN, AUTODETECTION, LINKCREDITS and MFS can be edited only if the port state is OOS,MT or OOS,DSBLD.
•The port parameters: AUTODETECTION, LINKCREDITS and MFS can be edited only if distance extension is enabled (set to B2B).
•When 1GFICON and 2GFICON payloads are provisioned, distance extension=B2B is the default and only valid setting. Setting distance extension (using the ED-nGFICON command) to any other setting will be denied with an error message, for example, Provisioning Rules Failed.
CategoryPorts
SecurityProvisioning
Related Commands
Input FormatED-<MOD1FCPAYLOAD>:[<TID>]:<AID>:<CTAG>:::[LINKRCVRY=<LINKRCVRY>],
[DISTEXTN=<DISTEXTN>],[AUTODETECTION=<AUTODETECTION>],
[LINKCREDITS=<LINKCREDITS>],[MFS=<MFS>],[NAME=<NAME>],
[CMDMDE=<CMDMDE>],[SOAK=<SOAK>],[FREQ=<FREQ>],
[LOSSB=<LOSSB>]:[<PST>[,[<SST>]];Input ExampleED-1GFC:CISCO:FAC-6-1:1:::LINKRCVRY=Y,DISTEXTN=NONE,AUTODETECTION=Y,
LINKCREDITS=10,MFS=2148,NAME="FC PORT",CMDMDE=CMDMDE,SOAK=32,
FREQ=1550,LOSSB=LR-1:OOS,MT;Input Parameters
Table 11-2 ED-<MOD1FCPAYLOAD> Input Parameters
Parameter and Values DescriptionAID
Access identifier from the "FACILITY" section
LINKRCVRY
Link recovery
Parameter type is ON_OFF—disable or enable an attribute
•N
Disable an attribute
•Y
Enable an attribute
DISTEXTN
Distance extension. It can be set to Buffer-to-Buffer (B2B) Credit Management state or None.
Note B2B and link recovery are mutually exclusive. You cannot turn on both B2B and link recovery at the same time
Parameter type is DISTANCE_EXTENSION—distance extension
•B2B
Buffer to buffer flow control
•NONE
No distance extension
AUTODETECTION
Autodetection. Turns autodetection on or off
Parameter type is ON_OFF—disable or enable an attribute
•N
Disable an attribute
•Y
Enable an attribute
LINKCREDITS
Number of link credits. If autodetection is set to off the value of the link credits will be used to configure the hardware. Integer
MFS
Maximum frame size. Integer
NAME
String
CMDMDE
Command execution mode, forced or normal. FRCD deletes all the VCG members and member cross-connects of a VCG
Parameter type is CMDMDE—forces the system to execute a given command regardless of any standing conditions. Normal mode is the default behavior for all commands but you can specify FRCD to force the system to override a state where the command would normally be denied
•FRCD
Force the system to override a state where the command would normally be denied
•NORM
Execute the command normally. Do not override any conditions that might make the command fail
SOAK
OOS-AINS to IS transition soak time as measured in 15-minute intervals. A value of 4 equals a soak time of 1 hour. The allowable range is 0 to 192 intervals (maximum of 48 hours). Integer
FREQ
Parameter type is OPTICAL-WLEN—optical wavelength
•1530.33
Wavelength 1
•1531.12
Wavelength 2
•1531.90
Wavelength 3
•1532.68
Wavelength 4
•1534.25
Wavelength 5
•1535.04
Wavelength 6
•1535.82
Wavelength 7
•1536.61
Wavelength 8
•1538.19
Wavelength 9
•1538.98
Wavelength 10
•1539.77
Wavelength 11
•1540.56
Wavelength 12
•1542.14
Wavelength 13
•1542.94
Wavelength 14
•1543.73
Wavelength 15
•1544.53
Wavelength 16
•1546.12
Wavelength 17
•1546.92
Wavelength 18
•1547.72
Wavelength 19
•1548.51
Wavelength 20
•1550.12
Wavelength 21
•1550.92
Wavelength 22
•1551.72
Wavelength 23
•1552.52
Wavelength 24
•1554.13
Wavelength 25
•1554.94
Wavelength 26
•1555.75
Wavelength 27
•1556.55
Wavelength 28
•1558.17
Wavelength 29
•1558.98
Wavelength 30
•1559.79
Wavelength 31
•1560.61
Wavelength 32
•USE-TWL1
Use Tunable Wavelength 1
LOSSB
Parameter type is REACH—reach values
•AUTOPROV
Autoprovisioning
•CX
Reach CX
•DX
Reach DX
•HX
Reach HX
•I1
Reach I1
•IR-1
Reach IR-1
•IR-2
Reach IR-2
•L1
Reach L1
•L2
Reach L2
•L3
Reach L3
•LR-1
Reach LR-1
•LR-2
Reach LR-2
•LR-3
Reach LR-3
•LX
Reach LX
•S1
Reach S1
•S2
Reach S2
•SR
Reach SR
•SR-1
Reach SR-1
•SX
Reach SX
•T
Reach T
•VX
Reach VX
•ZX
Reach ZX
PST
Primary state
Parameter type is PST—indicates the current overall service condition of an entity
•IS
In service
•OOS
Out of service
SST
Secondary state
Parameter type is SST—provides additional information pertaining to PST and PSTQ
•AINS
Automatic in service
•DSBLD
Disabled
•LPBK
Loopback
•MEA
Mismatch of equipment and attributes
•MT
Maintenance mode
•OOG
Out of group
•SWDL
Software downloading
•UAS
Unassigned
•UEQ
Unequipped
11.3 ED-<MOD1FICONPAYLOAD>
Edit (1GFICON, 2GFICON)
Usage Guidelines
Cisco ONS 15454
See Table 27-1 for supported modifiers by platform.
This command edits the attributes related with the FICON payload facility. The state IS,AINS is not supported on the FICON port.
CategoryPorts
SecurityProvisioning
Related Commands
Input FormatED-<MOD1FICONPAYLOAD>:[<TID>]:<AID>:<CTAG>:::[LINKRCVRY=<LINKRCVRY>],
[DISTEXTN=<DISTEXTN>],[AUTODETECTION=<AUTODETECTION>],
[LINKCREDITS=<LINKCREDITS>],[MFS=<MFS>],[NAME=<NAME>],
[CMDMDE=<CMDMDE>],[SOAK=<SOAK>],[FREQ=<FREQ>],
[LOSSB=<LOSSB>]:[<PST>[,<SST>]];Input ExampleED-1GFICON:CISCO:FAC-6-1:1:::LINKRCVRY=Y,DISTEXTN=NONE,AUTODETECTION=Y,
LINKCREDITS=10,MFS=2148,NAME="FC PORT",CMDMDE=CMDMDE,SOAK=32,FREQ=1550,
LOSSB=LR-1:OOS,MT;Input Parameters
Table 11-3 ED-<MOD1FICONPAYLOAD> Input Parameters
Parameter and Values DescriptionAID
Access identifier from the "FACILITY" section
LINKRCVRY
Link recovery
Parameter type is ON_OFF—disable or enable an attribute
•N
Disable an attribute
•Y
Enable an attribute
DISTEXTN
Distance extension. It can be set to Buffer-to-Buffer (B2B) Credit Management state or None.
Note B2B and link recovery are mutually exclusive. You cannot turn on both B2B and link recovery at the same time
Parameter type is DISTANCE_EXTENSION—distance extension
•B2B
Buffer to buffer flow control
•NONE
No distance extension
AUTODETECTION
Autodetection. Turns autodetection on or off
Parameter type is ON_OFF—disable or enable an attribute
•N
Disable an attribute
•Y
Enable an attribute
LINKCREDITS
Number of link credits. If autodetection is set to off the value of the link credits will be used to configure the hardware. Integer
MFS
Maximum frame size. Integer
NAME
String
CMDMDE
Command execution mode, forced or normal. FRCD deletes all the VCG members and member cross-connects of a VCG
Parameter type is CMDMDE—forces the system to execute a given command regardless of any standing conditions. Normal mode is the default behavior for all commands but you can specify FRCD to force the system to override a state where the command would normally be denied
•FRCD
Force the system to override a state where the command would normally be denied
•NORM
Execute the command normally. Do not override any conditions that might make the command fail
SOAK
OOS-AINS to IS transition soak time as measured in 15-minute intervals. A value of 4 equals a soak time of 1 hour. The allowable range is 0 to 192 intervals (maximum of 48 hours). Integer
FREQ
Parameter type is OPTICAL-WLEN—optical wavelength
•1530.33
Wavelength 1
•1531.12
Wavelength 2
•1531.90
Wavelength 3
•1532.68
Wavelength 4
•1534.25
Wavelength 5
•1535.04
Wavelength 6
•1535.82
Wavelength 7
•1536.61
Wavelength 8
•1538.19
Wavelength 9
•1538.98
Wavelength 10
•1539.77
Wavelength 11
•1540.56
Wavelength 12
•1542.14
Wavelength 13
•1542.94
Wavelength 14
•1543.73
Wavelength 15
•1544.53
Wavelength 16
•1546.12
Wavelength 17
•1546.92
Wavelength 18
•1547.72
Wavelength 19
•1548.51
Wavelength 20
•1550.12
Wavelength 21
•1550.92
Wavelength 22
•1551.72
Wavelength 23
•1552.52
Wavelength 24
•1554.13
Wavelength 25
•1554.94
Wavelength 26
•1555.75
Wavelength 27
•1556.55
Wavelength 28
•1558.17
Wavelength 29
•1558.98
Wavelength 30
•1559.79
Wavelength 31
•1560.61
Wavelength 32
•USE-TWL1
Use Tunable Wavelength 1
LOSSB
Parameter type is REACH—reach values
•AUTOPROV
Autoprovisioning
•CX
Reach CX
•DX
Reach DX
•HX
Reach HX
•I1
Reach I1
•IR-1
Reach IR-1
•IR-2
Reach IR-2
•L1
Reach L1
•L2
Reach L2
•L3
Reach L3
•LR-1
Reach LR-1
•LR-2
Reach LR-2
•LR-3
Reach LR-3
•LX
Reach LX
•S1
Reach S1
•S2
Reach S2
•SR
Reach SR
•SR-1
Reach SR-1
•SX
Reach SX
•T
Reach T
•VX
Reach VX
•ZX
Reach ZX
PST
Primary state
Parameter type is PST—indicates the current overall service condition of an entity
•IS
In service
•OOS
Out of service
SST
Secondary state
Parameter type is SST—provides additional information pertaining to PST and PSTQ
•AINS
Automatic in service
•DSBLD
Disabled
•LPBK
Loopback
•MEA
Mismatch of equipment and attributes
•MT
Maintenance mode
•OOG
Out of group
•SWDL
Software downloading
•UAS
Unassigned
•UEQ
Unequipped
11.4 ED-<MOD2DWDMPAYLOAD>
Edit (10GFC, 10GIGE, 1GFC, 1GFICON, 2GFC, 2GFICON, D1VIDEO, DV6000, ETRCLO, GIGE, HDTV, ISC1, ISC3, PASSTHRU)
Usage Guidelines
Cisco ONS 15454
See Table 27-1 for supported modifiers by platform.
This command edits the operating parameters for a DWDM client facility.
CategoryDWDM
SecurityProvisioning
Related Commands
Input FormatED-<MOD2DWDMPAYLOAD>:[<TID>]:<AID>:<CTAG>:::[NAME=<NAME>],
[CMDMDE=<CMDMDE>],[FREQ=<FREQ>],[LOSSB=<LOSSB>]:[<PST>[,<SST>]];Input ExampleED-HDTV::FAC-1-1:1:::NAME="PORTNAME",CMDMDE=CMDMDE,FREQ=1550,
LOSSB=LR-1:IS,AINS;Input Parameters
Table 11-4 ED-<MOD2DWDMPAYLOAD> Input Parameters
Parameter and Values DescriptionAID
Access identifier from the "FACILITY" section
LINKCREDITS
Number of link credits. If autodetection is set to off the value of the link credits will be used to configure the hardware. Integer
NAME
String
CMDMDE
Command execution mode, forced or normal. FRCD deletes all the VCG members and member cross-connects of a VCG
Parameter type is CMDMDE—forces the system to execute a given command regardless of any standing conditions. Normal mode is the default behavior for all commands but you can specify FRCD to force the system to override a state where the command would normally be denied
•FRCD
Force the system to override a state where the command would normally be denied
•NORM
Execute the command normally. Do not override any conditions that might make the command fail
FREQ
Parameter type is OPTICAL-WLEN—optical wavelength
•1530.33
Wavelength 1
•1531.12
Wavelength 2
•1531.90
Wavelength 3
•1532.68
Wavelength 4
•1534.25
Wavelength 5
•1535.04
Wavelength 6
•1535.82
Wavelength 7
•1536.61
Wavelength 8
•1538.19
Wavelength 9
•1538.98
Wavelength 10
•1539.77
Wavelength 11
•1540.56
Wavelength 12
•1542.14
Wavelength 13
•1542.94
Wavelength 14
•1543.73
Wavelength 15
•1544.53
Wavelength 16
•1546.12
Wavelength 17
•1546.92
Wavelength 18
•1547.72
Wavelength 19
•1548.51
Wavelength 20
•1550.12
Wavelength 21
•1550.92
Wavelength 22
•1551.72
Wavelength 23
•1552.52
Wavelength 24
•1554.13
Wavelength 25
•1554.94
Wavelength 26
•1555.75
Wavelength 27
•1556.55
Wavelength 28
•1558.17
Wavelength 29
•1558.98
Wavelength 30
•1559.79
Wavelength 31
•1560.61
Wavelength 32
•USE-TWL1
Use Tunable Wavelength 1
LOSSB
Parameter type is REACH—reach values
•AUTOPROV
Autoprovisioning
•CX
Reach CX
•DX
Reach DX
•HX
Reach HX
•I1
Reach I1
•IR-1
Reach IR-1
•IR-2
Reach IR-2
•L1
Reach L1
•L2
Reach L2
•L3
Reach L3
•LR-1
Reach LR-1
•LR-2
Reach LR-2
•LR-3
Reach LR-3
•LX
Reach LX
•S1
Reach S1
•S2
Reach S2
•SR
Reach SR
•SR-1
Reach SR-1
•SX
Reach SX
•T
Reach T
•VX
Reach VX
•ZX
Reach ZX
PST
Primary state
Parameter type is PST—indicates the current overall service condition of an entity
•IS
In service
•OOS
Out of service
SST
Secondary state
Parameter type is SST—provides additional information pertaining to PST and PSTQ
•AINS
Automatic in service
•DSBLD
Disabled
•LPBK
Loopback
•MEA
Mismatch of equipment and attributes
•MT
Maintenance mode
•OOG
Out of group
•SWDL
Software downloading
•UAS
Unassigned
•UEQ
Unequipped
11.5 ED-<MOD_PATH>
Edit (STS1, STS12C, STS18C, STS192C, STS24C, STS36C, STS3C, STS48C, STS6C, STS9C, VC12, VC3, VT1, VT2)
This command edits the attributes associated with STS and VT paths.
Usage Guidelines
Cisco ONS 15454, ONS 15327, ONS 15600, ONS 15310-CL
The SFBER, SDBER, RVRTV, and RVTM parameters only apply to path protection at the STS path level and ONS 15310_CL and ONS 15454 VT paths.
SFBER and SDBER also apply to the VT path level on the ONS 15310-CL and ONS 15454 when the ONS 15454 has an XC-VXC-10G card.
SWPDIP does not apply to the VT path level (VT1 and VT2).
The path trace message is a 64 character string including the terminating CR (carriage return) and LF (line feed) that is transported in the J1 byte of the SONET STS Path overhead. Both the EXPTRC and TRC string can be provisioned by user with up to 62 character string.
The EXPTRC indicates the contents of the expected incoming path trace are provisioned by the user. The TRC indicates the contents of the outgoing path trace message. The INCTRC indicates the contents of the incoming path trace message.
The path trace mode has three modes: OFF, MANUAL, and AUTO. The path trace mode defaults to OFF. The MANUAL mode performs the comparison of the received string with the user-entered expected string. The AUTO mode performs the comparison of the present received string with an expected string set to a previously received string. If there is a mismatch, TIM-P alarm is raised. When the path trace is in OFF mode, there is no path trace processing, and all the alarm and state conditions are reset.
The TACC parameter edits an existing single STS or VT and changes it to a test access point. When an editing command on TACC is executed, it assigns the STS or VT for the first 2-way connection and STS+1 as the second 2-way connection. For single FAD test access only a single STS/VT is used for the TAP creation. For more information on TACC, refer to the Cisco ONS SONET TL1 Reference Guide.
J1 is implemented on the DS1/DS1N, DS3E/DS3NE, DS3XM, EC1, OC3, OC12-4, OC48AS and OC192 cards.
DS3/DS3N, OC12, OC48, E100, and E1000 cards do not support path trace.
DS1/DS1N, DS3E/DS3NE, and DS3XM support both TRC and EXPTRC in the ED-STS-PATH command.
EC1, OC3, OC48AS, and OC192 only support EXPTRC in the ED-STS-PATH command.
Note Each TL1 command must be less than or equal to 255 characters. Any command larger than 255 characters must be split into multiple commands. For example, if you use the ED-<MOD_PATH> command to edit the J1 EXPTRC/TRC message, path protection attributes, and TACC attributes and the command exceeds 255 characters the command will not be processed. You must use multiple ED-<MOD_PATH> commands instead.
The following actions will produce error messages:
1. Sending this command to edit SFBER, SDBER, RVRTV or RVTM for the non-path protection STS path.
2. Sending this command to edit the EXPTRC string with the AUTO path trace mode (TRCMODE=AUTO).
3. Sending this command to edit TRC on any card other than DS3(N)E, DS1(N), and DS3XM cards, will return the "TRC-not allowed for monitor paths. Incorrect card type" error message.
4. Sending this command to edit both TACC and any other attribute(s) will return the "Parameters Not compatible" error message.
5. Sending this command to edit TACC on an AID with cross-connections will return the "STS in Use" error message.
Note•TACC creation will be denied on the protect ports/cards for 1:1, 1:N, and 1+1.
•The VFAC AID is only valid on slots containing an ML-Series card. TACC is not supported for the ML-Series cards.
•After the BLSR switching, provisioning of the J1 trace string or trace mode is not allowed on the protection path.
•TACC creation is allowed on PCA for two-fiber and four-fiber BLSR.
•TACC is not supported on G1000, MXP_2.5_10G/TXP_MR-10G, ML1000-2 and ML100T-12 cards.
•HOLDOFFTIMER is not specific to a path. It is applicable to the path protection selector. If HOLDOFFTIMER is changed on one path associated with the selector, the HOLDOFFTIMER of the other path associated with the same selector is also changed.
•The test set physical connection set up through ED-T3/DS1/STS1/VT1 of the DS3XM-12 card is only allowed on the physical front ports (PORTED ports, ports 1-12), which are the monitoring ports.
–The monitoring test access ports follow the common rules for the other cards. For example, ED-T3 on port 2 (FAC-6-2) with a TACC number (8), the next port, port 3 (FAC-6-3) is used as the monitoring point also. The RTRV-T3 on both port-2 and port-3 return the same TACC number (8) used to monitor the cross-connection end (A-B). The last port (port 12) is not allowed to set up a physical connection with the test set because there is no next available port to be the monitoring port.
–The TACC disconnection (DISC-TACC) and the test access mode change command (CHG-TACC) follow the same requirement as in the step above, but it is applied on the ported ports of the DS3XM-12 card.
–The test access connection set-up command (CONN-TACC) has monitored points, which can be portless ports. This command is applied on both ported and portless ports of the DS3XM-12 card.
•If the entity has a TACC connection, the entity is not allowed to have ported or portless STS/VT cross-connection (or circuit) provisioning on the DS3XM-12 card.
•Test Access is not supported on the ONS 15310-CL.
•J2 path trace is not supported on the 15310-CL-CTX card of the ONS 15310-CL, however the CE-100T-8/ML-100T-8 card provisioned in mapper mode does allow J2 provisioning.
•The cross-connects on the DS3I card will be STS3C width, but the individual STS 1s within the 3C will be accessible. For editing the path attributes use the ED-STS1 command with the FAC AID.
For TACC creation, use the ED-STS3C command because the TACC path width (like the cross-connect) has to be 3C on the DS3I card. In this case, you are creating a new entity (TAP) on the DS3I card that has to be of 3C width. On the DS3I card the ED0STS command can be used either with STS1 or STS3C depending on the parameter to be modified.
•For the selector path on a BLSR, the SWPDIP is not editable and is always in the ON state. If you attempt to edit SWPDIP (for the selector path on a BLSR), an error message will be returned.
•You can create an STS1 or VT1.5 single TAP on the DS3XM-12 card's last ported port (12) if the bandwidth is available on that port.
•Optical ports do not support MAN and AUTO trace mode because they are not capable of raising AIS on TIM-P. Use AUTO-NO-AIS or MAN-NO-AIS trace mode on optical ports.
•Sending the ED-VT1/VT2 commands over ONS 15454 path protection paths to edit SFBER or SDBER (when the ONS 15454 does not have an XC-VXC-10G cross-connect) will return the "Invalid Operation For The XCON" error message.
•Sending the ED-VT1/VT2 commands to edit SDBER with 1E-9 will return the "Out Of Range" error message.
CategoryPaths
SecurityProvisioning
Related Commands
Input FormatED-<MOD_PATH>:[<TID>]:<AID>:<CTAG>:::[SFBER=<SFBER>],[SDBER=<SDBER>],
[RVRTV=<RVRTV>],[RVTM=<RVTM>],[SWPDIP=<SWPDIP>],
[HOLDOFFTIMER=<HOLDOFFTIMER>],[EXPTRC=<EXPTRC>],[TRC=<TRC>],
[TRCMODE=<TRCMODE>],[TRCFORMAT=<TRCFORMAT>][TACC=<TACC>],
[TAPTYPE=<TAPTYPE>],[CMDMDE=<CMDMDE>]:[<PST>[,<SST>]];Input ExampleED-STS3C:FERNDALE:STS-2-1-4:115:::SFBER=1E-3,SDBER=1E-5,RVRTV=Y,RVTM=1.0,
SWPDIP=Y,HOLDOFFTIMER=2000,EXPTRC="EXPTRCSTRING",TRC="TRCSTRING",
TRCMODE=OFF,TRCFORMAT=64-BYTE,TACC=8,TAPTYPE=SINGLE,
CMDMDE=CMDMDE:IS,AINS;Input Parameters
Table 11-5 ED-<MOD_PATH> Input Parameters
Parameter and Values DescriptionAID
Access identifier from the "CrossConnectId1" section
SFBER
Signal failure threshold. Applies only to path protection. Applies to STS-level paths in SONET (STSn) and to VT-level paths on the ONS 15310-CL with an XC-VXC-10G card. Defaults to 1E-4
Parameter type is SF_BER—the threshold for declaring signal failure on a facility or path
•1E-3
SFBER is 1E-3
•1E-4
SFBER is 1E-4
•1E-5
SFBER is 1E-5
SDBER
Signal degrade threshold. Applies only to path protection. Applies to STS-level paths in SONET (STSn) and to VT-level paths on the ONS 15310-CL with an XC-VXC-10G card. 1E-9 is not allowed for VT-level/LO paths. Defaults to 1E-6
Parameter type is SD_BER—the threshold for declaring signal degrade on a facility or path
•1E-5
SDBER is 1E-5
•1E-6
SDBER is 1E-6
•1E-7
SDBER is 1E-7
•1E-8
SDBER is 1E-8
•1E-9
SDBER is 1E-9
RVRTV
Revertive mode. The value Y indicates that the protection switching system reverts service to the original line after restoration. The value N indicates that the protection switching system does not revert service to the original line after restoration. RVRTV is applicable only for 1+1 protection switching. Null defaults to N. Only applies to path protection
Parameter type is ON_OFF—disable or enable an attribute
•N
Disable an attribute
•Y
Enable an attribute
RVTM
Revertive time. RVTM is not allowed to be set while "RVRTV" is N. Only applies to path protection
Parameter type is REVERTIVE_TIME—revertive time
•0.5 to 12.0
Revertive time is 0.5 to 12.0 minutes
SWPDIP
On-off switch for path protection payload defect level switching. Applicable only to STS-level paths in SONET (STSn). For the selector path on a BLSR, SWPDIP is not editable and always ON. Defaults to N
Parameter type is ON_OFF—disable or enable an attribute
•N
Disable an attribute
•Y
Enable an attribute
HOLDOFFTIMER
Hold off timer for path protection DRI. Values must be within 0 and 10000 ms (0 - 10 seconds), with increments of 100 ms. Defaults to "existed value." Integer
EXPTRC
Expected path trace content. Indicates the expected path trace message (J1) contents. EXPTRC is any 64-character ASCII string, including the terminating CR (carriage return) and LF (line feed). Applicable to STS-level paths in SONET (STSn). Applicable to VT-level paths for the DS3XM-12 and CE-100T-8 card on the ONS 15454 and the CE-100T-8 card on ONS 15310-CL. Defaults to 64 null characters. String
TRC
The path trace message to be transmitted. The trace byte (J1) continuously transmits a 64-byte, fixed length ASCII string, one byte at a time. A null value defaults to the NE transmitting 62 null characters (hex 00) and CR and LF. Applicable to STS-level paths in SONET (STSn). Applicable to VT-level paths for the DS3XM-12 and CE-100T-8 card on the ONS 15454 and the CE-100T-8 card on ONS 15310-CL. For ONS 15310-CL, TRC is not provisionable on the EC/OC ports. Defaults to 64 null characters. String
TRCMODE
Path trace mode. Applicable only to STS-level paths in SONET (STSn). Defaults to the OFF mode. ONS 15310-CL EC/OC ports do not support MAN and AUTO, but can be configured as MAN-NO-AIS and AUTO-NO-AIS.
Note The ONS 15600 does not support MAN and AUTO
Parameter type is TRCMODE—trace mode
•AUTO
Use the previously received path trace string as the expected string. Not applicable to MXP/TXP cards
•AUTO-NO-AIS
Use the previously received path trace string as the expected string and do not turn on AIS and RDI if TIM-P is detected
•MAN
Use the provisioned expected string as the expected string
•MAN-NO-AIS
Use the provisioned expected string as the expected string and do not turn on AIS and RDI if TIM-P is detected
•OFF
Turn off path trace capability. Nothing will be reported
TRCFORMAT
Path trace format. Only 64-byte is supported. Defaults to 64-byte
Parameter type is TRCFORMAT—trace format
•64-BYTE
64 byte trace message
TACC
TAP number within a range of 0 to 999. Indicates whether the digroup being provisioned is to be used as a test access digroup. When TACC is 0 (zero), the TAP is deleted. Integer
TAPTYPE
TAP type. Defaults to DUAL
Parameter type is TAPTYPE—test access point type
•DUAL
Dual FAD
•SINGLE
Single FAD
CMDMDE
Command mode
Parameter type is CMDMDE—forces the system to execute a given command regardless of any standing conditions. Normal mode is the default behavior for all commands but you can specify FRCD to force the system to override a state where the command would normally be denied. Defaults to NORM
•FRCD
Force the system to override a state where the command would normally be denied
•NORM
Execute the command normally. Do not override any conditions that might make the command fail
PST
Primary state. Defaults to IS
Parameter type is PST—indicates the current overall service condition of an entity
•IS
In service
•OOS
Out of service
SST
Secondary state. Defaults to AINS
Parameter type is SST—provides additional information pertaining to PST and PSTQ
•AINS
Automatic in service
•DSBLD
Disabled
•LPBK
Loopback
•MEA
Mismatch of equipment and attributes
•MT
Maintenance mode
•OOG
Out of group
•SWDL
Software downloading
•UAS
Unassigned
•UEQ
Unequipped
11.6 ED-<MOD_RING>
Edit Bidirectional Line Switched Ring
Usage Guidelines
Cisco ONS 15454, ONS 15327, ONS 15600
This command edits the BLSR attributes.
ONS 15327 and ONS 15600 do not support four-fiber BLSR.
The RVRTV, RVTM, SRVRTV, SRVTM, NODEID, and RINGID attributes can be edited for the four-fiber BLSR.
The RVRTV, RVTM, NODEID, and RINGID attributes can be edited for the two-Fiber BLSR.
The following actions will produce errors:
•If the system fails on getting IOR, a SROF (Get IOR Failed) error message is returned
•If the AID is invalid, an IIAC (Invalid AID) error message is returned.
•If the BLSR does not exist, a SRQN (BLSR Does Not Exist) error message is returned.
•The SROF (Facility Not Provisioned) or (Cannot Access BLSR) error message will be returned for an invalid query.
•The SRQN (BLSR Edition Failed) error message is returned for an invalid edition query.
•Sending this command to modify SRVRTV or SRVTM on a two-fiber BLSR will return an IDNV (Invalid Data For 2F-BLSR) error message.
•Sending this command to modify the nodeid with invalid data will return an IIAC (Invalid NodeId) error message.
•Sending this command to change the ringid into invalid data will return an IIAC (Invalid RingId) error message.
•Changing the BLSR nodeid with a duplicated ID will return a SROF (Cannot Set NodeId) error message.
•Changing the BLSR ringid with a duplicated ID will return a SROF (Cannot Set RingId) error message is returned.
Note•The ALL AID is invalid for this command.
•The list AID format has been supported since R4.6.
CategoryBLSR
SecurityProvisioning
Related Commands
Input FormatED-<MOD_RING>:[<TID>]:<AID>:<CTAG>:::[RINGID=<RINGID>],[NODEID=<NODEID>],
[RVRTV=<RVRTV>],[RVTM=<RVTM>],[SRVRTV=<SRVRTV>],[SRVTM=<SRVTM>][:];Input ExampleED-BLSR:PETALUMA:BLSR-43:123:::RINGID=43,NODEID=3,RVRTV=Y,RVTM=2.0,
SRVRTV=Y,SRVTM=5.0;Input Parameters
Table 11-6 ED-<MOD_RING> Input Parameters
Parameter and Values DescriptionAID
Access identifier from the "AidUnionId1" section. Identifies the BLSR of the NE. ALL or BLSR-ALL AID is not allowed for editing a BLSR
RINGID
The BLSR ID of the NE up to six characters. Valid characters are A-Z and 0-9. String
NODEID
The BLSR node ID of the NE. NODEID ranges from 0 to 31. Integer
RVRTV
Revertive mode. The value Y indicates that the protection switching system reverts service to the original line after restoration. The value N indicates that the protection switching system does not revert service to the original line after restoration. RVRTV is applicable only for 1+1 protection switching. Null defaults to N
Parameter type is ON_OFF—disable or enable an attribute
•N
Disable an attribute
•Y
Enable an attribute
RVTM
Revertive time. RVTM is not allowed to be set while "RVRTV" is N
Parameter type is REVERTIVE_TIME—revertive time
•0.5 to 12.0
Revertive time is 0.5 to 12.0 minutes
SRVRTV
The span revertive mode for four-fiber BLSR only
Parameter type is ON_OFF—disable or enable an attribute
•N
Disable an attribute
•Y
Enable an attribute
SRVTM
The span revertive time for four-fiber BLSR only. SRVTM is not allowed to be set while SRVRTV is N
Parameter type is REVERTIVE_TIME—revertive time
•0.5 to 12.0
Revertive time is 0.5 to 12.0 minutes
11.7 ED-<OCN_TYPE>
Edit (OC3, OC12, OC48, OC192)
Usage Guidelines
Cisco ONS 15454, ONS 15327, ONS 15600, ONS 15310-CL
See Table 27-1 for supported modifiers by platform.
This command edits the attributes (for example, service parameters) and status of an OC-N facility. Allowable states for a facility are Out Of Service (OOS), Out Of Service with Automatic In Service transitioning (OOS-AINS), Out Of Service for Maintenance (OOS-MT), and In Service (IS).
The DCC transmit is bridged to both working and protect in a 1+1 protection scheme. On the receive side, the active one is selected for DCC. The DCC is provisioned on the working port only in a 1+1 protection scheme.
All lines in a 1+1 BLSR must have the same mode. If you change the mode of a line that is in a 1+1 BLSR, an error message will be returned.
UNI-C DCC provisioning notes:
1. The attributes DCC(Y/N) and mode (SONET/SDH) remain the same in the ED/RTRV-OCN commands when the DCC is used for UNI-C, in which case the port attribute UNIC is enables (UNIC=Y).
2. UNI-C DCC termination cannot be deleted by the regular DCC deprovisioning command.
3. If the DCC is created under regular SONET provisioning, and this port is used by UNI-C, the port is converted as a UNI-C DCC automatically.
4. Deprovisioning UNI-C IF/IB IPCC will free up DCC termination automatically.
5. The parameters ALSMODE, ALSCRINT and ALSRCPW are valid only for OC3-8, OC-192, and OC48ELR cards.
6. SDCC/LDCC termination cannot be unprovisioned if a provisionable patchcord termination end point is provisioned on the port.
7. SSM selectable (admssm) and synchronization messaging for output (syncmsgout) are not applicable to ONS 15600.
8. The default values for all optional parameters are NE default values. These values might not be the current value for a parameter. In order to obtain the current value, issue the RTRV-XX command.
9. J0 Support (EXPTRC, TRC, TRCMODE and TRCFORMAT parameters) is supported only by DWDM cards with an OCn payload. J0 is not supported by OC3-8, OC12, OC48, OC192 and other optical cards.
CategoryPorts
SecurityProvisioning
Related Commands
Input FormatED-<OCN_TYPE>:[<TID>]:<AID>:<CTAG>:::[DCC=<DCC>],[AREA=<AREA>],
[SYNCMSG=<SYNCMSG>],[SENDDUS=<SENDDUS>],[PJMON=<PJMON>],
[SFBER=<SFBER>],[SDBER=<SDBER>],[MODE=<MODE>],[MUX=<MUX>],
[SOAK=<SOAK>],[OSPF=<OSPF>],[LDCC=<LDCC>],[NAME=<NAME>],
[CMDMDE=<CMDMDE>],[EXPTRC=<EXPTRC>],[TRC=<TRC>],[TRCMODE=<TRCMODE>],
[TRCFORMAT=<TRCFORMAT>],[ADMSSM=<ADMSSM>],[SENDDUSFF=<SENDDUSFF>],
[AISONLPBK=<AISONLPBK>],[FREQ=<FREQ>],[LOSSB=<LOSSB>],
[FOREIGNFEND=<FOREIGNFEND>],[FOREIGNIP=<FOREIGNIP>]:[<PST>[,<SST>]];Input ExampleED-OC48:PENNGROVE:FAC-6-1:114:::DCC=Y,AREA=10.92.63.1,SYNCMSG=N,
SENDDUS=N,PJMON=48,SFBER=1E-4,SDBER=1E-6,MODE=SONET,MUX=E2,SOAK=10,
OSPF=Y,LDCC=N,NAME="OCNPORT",CMDMDE=CMDMDE,EXPTRC="AAA",
TRC="AAA",TRCMODE=MAN,TRCFORMAT=16-BYTE,ADMSSM=PRS,SENDDUSFF=N,
AISONLPBK=AIS_ON_LPBK_ALL,FREQ=1550,LOSSB=LR-1,FOREIGNFEND=N,
FOREIGNIP="IP ADDRESS":IS,AINS;Input Parameters
Table 11-7 ED-<OCN_TYPE> Input Parameters
Parameter and Values DescriptionAID
Access identifier from the "FACILITY" section
DCC
Indicates whether or not the section DCC is to be used. Identifies the section DCC connection of the port
Parameter type is ON_OFF—disable or enable an attribute
•N
Disable an attribute
•Y
Enable an attribute
AREA
The area ID and shows up only if the DCC is enabled. String
SYNCMSG
Synchronization status message
Parameter type is EXT_RING—indicates if the ring supports the extended K1/K2/K3 protocol
•N
The ring does not support the extended K1/K2/K3 protocol
•Y
The ring does support the extended K1/K2/K3 protocol
SENDDUS
The facility will send the DUS (Don't use for Synchronization) value as the sync status message for that facility
Parameter type is ON_OFF—disable or enable an attribute
•N
Disable an attribute
•Y
Enable an attribute
PJMON
Identifies an OCn port PJMON. Integer
SFBER
Signal failure threshold
Parameter type is SF_BER—the threshold for declaring signal failure on a facility or path
•1E-3
SFBER is 1E-3
•1E-4
SFBER is 1E-4
•1E-5
SFBER is 1E-5
SDBER
Signal degrade threshold
Parameter type is SD_BER—the threshold for declaring signal degrade on a facility or path
•1E-5
SDBER is 1E-5
•1E-6
SDBER is 1E-6
•1E-7
SDBER is 1E-7
•1E-8
SDBER is 1E-8
•1E-9
SDBER is 1E-9
MODE
OCn port mode
Parameter type is OPTICAL_MODE—the facility's optical mode
•SDH
SDH/ETSI optical mode using European/International format
•SONET
SONET/ANSI optical mode using the American format
MUX
BLSR extension byte (supported only on the OC48AS card). MUX cannot be configured if:
•The card is SONET and the media type is SDHT
•The card has an orderwire or UDC connection
•This is a protect line and the working line has an orderwire or UDC connection
Parameter type is MUX_TYPE—BLSR extension type
•E2
E2 byte (orderwire)
•F1
F1 byte (user)
•K3
K3 byte
•Z2
Z2 byte
SOAK
OOS-AINS to IS transition soak time as measured in 15-minute intervals. A value of 4 equals a soak time of 1 hour. The allowable range is 0 to 192 intervals (maximum of 48 hours). Defaults to 32. Integer
OSFP
The open shortest path first discovery. Defaults to Y
Parameter type is ON_OFF—disable or enable an attribute
•N
Disable an attribute
•Y
Enable an attribute
LDCC
The line DCC connection on the port. Defaults to N
Parameter type is EXT_RING—indicates if the ring supports the extended K1/K2/K3 protocol
•N
The ring does not support the extended K1/K2/K3 protocol
•Y
The ring does support the extended K1/K2/K3 protocol
NAME
String. Defaults to NULL. Maximum length is 32 characters
CMDMDE
Command Mode. The FRCD mode of operation is applicable to delete a VCAT member cross-connect from IS-NR or OOS-AU,AINS service state. Defaults to NORM
Parameter type is CMDMDE—forces the system to execute a given command regardless of any standing conditions. Normal mode is the default behavior for all commands but you can specify FRCD to force the system to override a state where the command would normally be denied
•FRCD
Force the system to override a state where the command would normally be denied
•NORM
Execute the command normally. Do not override any conditions that might make the command fail
EXPTRC
Expected path trace content. Indicates the expected path trace message (J1) contents. EXPTRC is any 64-character ASCII string, including the terminating CR (carriage return) and LF (line feed). Applicable to STS-level paths in SONET (STSn). Applicable to VT-level paths for the DS3XM-12 card on the ONS 15454. Defaults to NULL. String
TRC
The path trace message to be transmitted. The trace byte (J1) continuously transmits a 64-byte, fixed length ASCII string, one byte at a time. A null value defaults to the NE transmitting 62 null characters (hex 00) and CR and LF. Applicable to STS-level paths in SONET (STSn). Applicable to VT-level paths for the DS3XM-12 card on the ONS 15454. String
TRCMODE
Path trace mode. Applicable only to STS-level Paths in SONET (STSn). Defaults to MAN
Parameter type is TRCMODE—trace mode
•AUTO
Use the previously received path trace string as the expected string. Not applicable to MXP/TXP cards
•AUTO-NO-AIS
Use the previously received path trace string as the expected string and do not turn on AIS and RDI if TIMP is detected
•MAN
Use the provisioned expected string as the expected string
•MAN-NO-AIS
Use the provisioned expected string as the expected string and do not turn on AIS and RDI if TIMP is detected
•OFF
Turn off path trace capability. Nothing will be reported
TRCFORMAT
Trace message size
Parameter type is TRCFORMAT—trace format
•1-BYTE
1 byte trace message
•16-BYTE
16 byte trace message
•64-BYTE
64 byte trace message
ADMSSM
SSM selectable value. It will only appear when SSM is disabled. Defaults to STU
Parameter type is SYNC_CLOCK_REF_QUALITY_LEVEL—clock source quality level for SONET
•DUS
Do Not Use For Synchronization
•PRS
Primary Reference Source, Stratum 1 Traceable
•RES
Reserved For Network Synchronization Use
•SMC
SONET Minimum Clock Traceable
•ST2
Stratum 2 Traceable
•ST3
Stratum 3 Traceable
•ST3E
Stratum 3E Traceable
•ST4
Stratum 4 Traceable
•STU
Synchronized, Traceability Unknown
•TNC
Transit Node Clock (2nd Generation Only)
SENDDUSFF
Parameter type is ON_OFF—disable or enable an attribute
•N
Disable an attribute
•Y
Enable an attribute
AISONLPBK
Parameter type is AIS_ON_LPBK—Indicates if AIS is sent on a loopback
•AIS_ONLPBK_FACILITY
AIS is sent on facility loopbacks
•AIS_ON_LPBK_ALL
AIS is sent on all loopbacks
•AIS_ON_LPBK_OFF
AIS is not sent on loopbacks
•AIS_ON_LPBK_TERMINAL
AIS is sent on terminal loopbacks
FREQ
Parameter type is OPTICAL-WLEN—optical wavelength
•1530.33
Wavelength 1
•1531.12
Wavelength 2
•1531.90
Wavelength 3
•1532.68
Wavelength 4
•1534.25
Wavelength 5
•1535.04
Wavelength 6
•1535.82
Wavelength 7
•1536.61
Wavelength 8
•1538.19
Wavelength 9
•1538.98
Wavelength 10
•1539.77
Wavelength 11
•1540.56
Wavelength 12
•1542.14
Wavelength 13
•1542.94
Wavelength 14
•1543.73
Wavelength 15
•1544.53
Wavelength 16
•1546.12
Wavelength 17
•1546.92
Wavelength 18
•1547.72
Wavelength 19
•1548.51
Wavelength 20
•1550.12
Wavelength 21
•1550.92
Wavelength 22
•1551.72
Wavelength 23
•1552.52
Wavelength 24
•1554.13
Wavelength 25
•1554.94
Wavelength 26
•1555.75
Wavelength 27
•1556.55
Wavelength 28
•1558.17
Wavelength 29
•1558.98
Wavelength 30
•1559.79
Wavelength 31
•1560.61
Wavelength 32
•USE-TWL1
Use Tunable Wavelength 1
LOSSB
Parameter type is REACH—reach values
•AUTOPROV
Autoprovisioning
•CX
Reach CX
•DX
Reach DX
•HX
Reach HX
•I1
Reach I1
•IR-1
Reach IR-1
•IR-2
Reach IR-2
•L1
Reach L1
•L2
Reach L2
•L3
Reach L3
•LR-1
Reach LR-1
•LR-2
Reach LR-2
•LR-3
Reach LR-3
•LX
Reach LX
•S1
Reach S1
•S2
Reach S2
•SR
Reach SR
•SR-1
Reach SR-1
•SX
Reach SX
•T
Reach T
•VX
Reach VX
•ZX
Reach ZX
FOREIGNFEND
Indicates whether the far-end NE on the DCC is a foreign NE
Parameter type is ON_OFF—disable or enable an attribute
•N
Disable an attribute
•Y
Enable an attribute
FOREIGNIP
The IP address of the far-end NE on the DCC. Used only if FOREIGNFEND is Y. String
PST
Primary state. Defaults to IS
Parameter type is PST—indicates the current overall service condition of an entity
•IS
In service
•OOS
Out of service
SST
Secondary state. Defaults to AINS
Parameter type is SST—provides additional information pertaining to PST and PSTQ
•AINS
Automatic in service
•DSBLD
Disabled
•LPBK
Loopback
•MEA
Mismatch of equipment and attributes
•MT
Maintenance mode
•OOG
Out of group
•SWDL
Software downloading
•UAS
Unassigned
•UEQ
Unequipped
11.8 ED-ALS
Edit Automatic Laser Shutdown
Usage Guidelines
Cisco ONS 15454, ONS 15310-CL
This command is used to modify the ALS attributes of an OC-N facility and all the facilities that support the ALS feature. For MXP_2.5G_10E, TXP_MR_10E, MXP_2.5G_10G, TXP_MR_10G, TXP_MR_2.5G, and TXPP_MR_2.5G cards this command is used to modify the ALS parameter of the OC48 and OC192 ports.
CategoryPorts
SecurityProvisioning
Related Commands
Input FormatED-ALS:[<TID>]:<SRC>:<CTAG>:::[ALSMODE=<ALSMODE>],[ALSRCINT=<ALSRCINT>],
[ALSRCPW=<ALSRCPW>][:];Input ExampleED-ALS:CISCO:FAC-1-1:100:::ALSMODE=AUTO,ALSRCINT=130,ALSRCPW=35.1;
Input Parameters
Table 11-8 ED-ALS Input Parameters
Parameter and Values DescriptionSRC
Access identifier from the "AidUnionId" section
ALSMODE
ALS is enabled or disabled
Parameter type is ALS_MODE—the working mode for automatic laser shutdown
•AUTO
Automatic
•DISABLED
Disabled
•MAN
Manual
•MAN-RESTART
Manual restart for test
ALSRCINT
ALS recovery interval. The range is 60 to 300 seconds. Integer
ALSRCPW
ALS recovery pulse width. The range is 2.0 to 100.00 seconds, in increments of 100 ms. Float
11.9 ED-APC
Edit Amplification Power Control
Usage Guidelines
Cisco ONS 15454
This command is used to modify the APC application attributes. The default value for an optional parameter is the NE default value. The value might not be the current value for the parameter. Use a RTRV-xx command to retrieve the current value.
CategoryDWDM
SecurityProvisioning
Related Commands
Input FormatED-APC:[<TID>]::<CTAG>[:::APCENABLE=<APCENABLE>];
Input ExampleED-APC:PENNGROVE::CTAG:::APCENABLE=N;
Input Parameters
11.10 ED-BITS
Edit Building Integrated Timing Supply
Usage Guidelines
Cisco ONS 15454, ONS 15327, ONS 15600, ONS 15310-CL
This command edits the BITS reference attributes.
SYNC-BITS1 and SYNC-BITS2 AIDs can be used to set the BITS-OUT port state. For a BITS facility, 64 k and 6 MHz are only applicable to ON. SSM selectable (ADMSSM) is not applicable to ONS 15600.
The default values for all optional parameters are NE default values. These values might not be the current value for a parameter. In order to obtain the current value, issue the RTRV-XX command.
CategorySynchronization
SecurityProvisioning
Related Commands
ED-NE-SYNCN
ED-SYNCN
OPR-SYNCNSW
REPT ALM BITS
REPT ALM SYNCN
REPT EVT BITS
REPT EVT SYNCN
RLS-SYNCNSW
RTRV-ALM-BITS
RTRV-ALM-SYNCN
RTRV-BITS
RTRV-COND-BITS
RTRV-COND-SYNCN
RTRV-NE-SYNCN
RTRV-SYNCN
Input FormatED-BITS:[<TID>]:<AID>:<CTAG>:::[LINECDE=<LINECDE>],[FMT=<FMT>],[LBO=<LBO>],
[SYNCMSG=<SYNCMSG>],[AISTHRSHLD=<AISTHRSHLD>],[SABIT=<SABIT>],
[BITSFAC=<BITSFAC>],[ADMSSM=<ADMSSM>][:<PST>];Input ExampleED-BITS:SONOMA:BITS-2:779:::LINECDE=AMI,FMT=ESF,LBO=0-133,SYNCMSG=N,
AISTHRSHLD=PRS,SABIT=BYTE-5,IMPEDANCE=120-OHM,BITSFAC=T1,ADMSSM=PRS:IS;Input Parameters
Table 11-10 ED-BITS Input Parameters
Parameter and Values DescriptionAID
Access identifier from the "BITS" section
LINECDE
Line code
Parameter type is LINE_CODE—line code
•AMI
Line code value is AMI
•B8ZS
Line code value is B8ZS (bipolar with three-zero substitution)
FMT
Digital signal frame format
Parameter type is FRAME_FORMAT—frame format for a T1 port
•D4
Frame format is D4
•ESF
Frame format is ESF
•UNFRAMED
Frame format is unframed
LBO
Line build out settings. BITS line build out. Default value is 0 to 133. Integer
Parameter type is BITS_LineBuildOut—BITS line buildout
•0-133
BITS line buildout range is 0-133
•134-266
BITS line buildout range is 134-266
•267-399
BITS line buildout range is 267-399
•400-533
BITS line buildout range is 400-533
•534-655
BITS line buildout range is 534-655
SYNCMSG
Indicates if the BITS facility supports synchronization status message. Default is on (Y)
Parameter type is EXT_RING—indicates if the ring supports the extended K1/K2/K3 protocol
•N
The ring does not support the extended K1/K2/K3 protocol
•Y
The ring does support the extended K1/K2/K3 protocol
AISTHRSHLD
Alarm indication signal threshold
Parameter type is SYNC_CLOCK_REF_QUALITY_LEVEL—clock source quality level for SONET
•DUS
Do Not Use For Synchronization
•PRS
Primary Reference Source, Stratum 1 Traceable
•RES
Reserved For Network Synchronization Use
•SMC
SONET Minimum Clock Traceable
•ST2
Stratum 2 Traceable
•ST3
Stratum 3 Traceable
•ST3E
Stratum 3E Traceable
•ST4
Stratum 4 Traceable
•STU
Synchronized, Traceability Unknown
•TNC
Transit Node Clock (2nd Generation Only)
SABIT
When the frame format selection is E1, SABIT is the bit used to receive and transmit the SSM
Parameter type is SABITS—SA BITS
•BYTE-4
SABIT is BYTE-4
•BYTE-5
SABIT is BYTE-5
•BYTE-6
SABIT is BYTE-6
•BYTE-7
SABIT is BYTE-7
•BYTE-8
SABIT is BYTE-8
IMPEDANCE
When the frame format selection is E1, IMPEDANCE is the terminal impedance of the BITS-IN port
Parameter type is IMPEDANCE—the terminal impedance of the BITS-IN port
•120-OHM
Impedance of 120 ohm
•75-OHM
Impedance of 75 ohm
BITSFAC
BITS facility settings. BITS-2 always inherits the value of BITS-1
Parameter type is BITS_FAC—BITS facility rate. 64 k and 6 MHz are only applicable to the ONS 15454
•2 M
2 MHz rate
•64 K
64 K rate
•6 M
6 MHz rate
•E1
E1 rate
•T1
T1 rate
ADMSSM
SSM selectable. Only applicable to BITS-IN when SSM is disabled.
Note Not applicable for ONS 15600
Parameter type is SYNC_CLOCK_REF_QUALITY_LEVEL—clock source quality level for SONET
•DUS
Do Not Use For Synchronization
•PRS
Primary Reference Source, Stratum 1 Traceable
•RES
Reserved For Network Synchronization Use
•SMC
SONET Minimum Clock Traceable
•ST2
Stratum 2 Traceable
•ST3
Stratum 3 Traceable
•ST3E
Stratum 3E Traceable
•ST4
Stratum 4 Traceable
•STU
Synchronized, Traceability Unknown
•TNC
Transit Node Clock (2nd Generation Only)
PST
Primary state
Parameter type is PST—indicates the current overall service condition of an entity
•IS
In service
•OOS
Out of service
11.11 ED-BULKROLL-<OCN_TYPE>
Edit Bulkroll (OC12, OC192, OC3, OC48)
Usage Guidelines
Cisco ONS 15454, ONS 15327, ONS 15600
This command edits information about rolling of traffic from one end point to another without interrupting service. This command uses the FORCE option to force a valid signal. The only parameters that can be edited are RMODE and FORCE. The time slots cannot be edited. Use ED-ROLL-<MOD_PATH> for single path level rolling.
See Table 27-1 for supported modifiers by platform.
CategoryBridge and Roll
SecurityProvisioning
Related Commands
Input FormatED-BULKROLL-<OCN_TYPE>:[<TID>]:<FROM>:<CTAG>:::
[RFROMSTART=<RFROMSTART>],[RFROMEND=<RFROMEND>],[CMDMDE=<CMDMDE>];Input ExampleED-BULKROLL-OC48:CISCO:FAC-1-1:1:::RFROMSTART=STS-1-1-1,
RFROMEND=STS-1-1-11,CMDMDE=FRCD;Input Parameters
Table 11-11 ED-BULKROLL-<OCN_TYPE> Input Parameters
Parameter and Values DescriptionFROM
One of the end points. Access identifier from the "FACILITY" section for line level rolling and bulk rolling
RFROMSTART
The starting time slot in the source roll port. For bulk rolling only. The AID is from the "CrossConnectId1" section (except VCM and FACILITY). Defaults to STS-<FROMSLOT>-<FROMPORT>-1, where <FROMSLOT> and <FROMPORT> are the slot and port of the <FROM> AID.
RFROMEND
The ending time slot in the source roll port. For bulk rolling only. The AID is from the "CrossConnectId1" section (except VCM and FACILITY). Defaults to STS-<FROMSLOT>-<FROMPORT>-N, where <FROMSLOT> and <FROMPORT> are the slot and port of the <FROM> AID and N is the value of OCn. (for example, OC48, n=48)
CMDMDE
Command execution mode. Defaults to NORM
Parameter type is CMDMDE—forces the system to execute a given command regardless of any standing conditions. Normal mode is the default behavior for all commands but you can specify FRCD to force the system to override a state where the command would normally be denied
•FRCD
Force the system to override a state where the command would normally be denied
•NORM
Execute the command normally. Do not override any conditions that might make the command fail
11.12 ED-CMD-SECU
Edit Command Security
Usage Guidelines
Cisco ONS 15454, ONS 15327, ONS 15600, ONS 15310-CL
This command edits the command security level of a particular command.
CategorySecurity
SecuritySuperuser
Related Commands
Input FormatED-CMD-SECU:[<TID>]:<AID>:<CTAG>::<CAP>;
Input ExampleED-CMD-SECU::INIT-REG:1::SU;
Input Parameters
11.13 ED-CRS-<PATH>
Edit Cross-Connect (STS1, STS12C, STS18C, STS192C, STS24C, STS36C, STS3C, STS48C, STS6C, STS9C, VT1, VT2)
Usage Guidelines
Cisco ONS 15454, ONS 15327, ONS 15600, ONS 15310-CL
See Table 27-1 for supported modifiers by platform.
This command edits a cross-connection.
Note•ADD and REMOVE cannot be used together. The example provided is for informational purposes only. ADD and REMOVE are mutually exclusive.
•Add/Remove drops is possible only on ONEWAY, UPSR_DROP, UPSR_DC, and UPSR_EN type of cross-connects (one-way only).
•Traditional cross-connections cannot be upgraded to DRI cross-connections using the ED_CRS command.
•CKTID is a string of ASCII characters. The maximum length of CKTID is 48. If the CKTID is EMPTY or NULL this field will not appear.
•You cannot add a drop onto unidrectional connections on BLSR DRI primary or secondary nodes.
CategoryCross Connections
SecurityProvisioning
Related Commands
Input FormatED-CRS-<PATH>:[<TID>]:<SRC>,<DST>:<CTAG>:::[ADD=<ADD>],[REMOVE=<REMOVE>],
[CKTID=<CKTID>],[CMDMDE=<CMDMDE>]:[<PST>[,<SST>]];Input ExampleED-CRS-STS3C::STS-1-1-1,STS-2-1-1:1:::ADD=STS-13-1-1,REMOVE=STS-2-1-1,CKTID=CKTID
CMDMDE=CMDMDE:IS,AINS;Input Parameters
Table 11-13 ED-CRS-<PATH> Input Parameters
Parameter and Values DescriptionSRC
Source AID from the "CrossConnectId1" section
DST
Destination AID from the "CrossConnectId1" section
ADD
AID from the "AidUnionId" section
REMOVE
AID from the "AidUnionId" section
CKTID
String
CMDMDE
Command Mode. The FRCD mode of operation is applicable only if the PST=OOS and SST=DSBLD
Parameter type is CMDMDE—forces the system to execute a given command regardless of any standing conditions. Normal mode is the default behavior for all commands but you can specify FRCD to force the system to override a state where the command would normally be denied
•FRCD
Force the system to override a state where the command would normally be denied
•NORM
Execute the command normally. Do not override any conditions that might make the command fail
PST
Primary state
Parameter type is PST—indicates the current overall service condition of an entity
•IS
In service
•OOS
Out of service
SST
Secondary state
Parameter type is SST—provides additional information pertaining to PST and PSTQ
•AINS
Automatic in service
•DSBLD
Disabled
•LPBK
Loopback
•MEA
Mismatch of equipment and attributes
•MT
Maintenance mode
•OOG
Out of group
•SWDL
Software downloading
•UAS
Unassigned
•UEQ
Unequipped
11.14 ED-DAT
Edit Date and Time
Usage Guidelines
Cisco ONS 15454, ONS 15327, ONS 15600, ONS 15310-CL
This command edits the date and the time
CategorySystem
SecurityProvisioning
Related Commands
Input FormatED-DAT:[<TID>]::<CTAG>::[<DATE>],[<TIME>];
Input ExampleED-DAT:CISCO::1234::99-12-21,14-35-15;
Input Parameters
Table 11-14 ED-DAT Input Parameters
Parameter and Values DescriptionDATE
Date. String
TIME
Time. String
11.15 ED-DS1
Edit DS1
Usage Guidelines
Cisco ONS 15454
This command edits the test access attribute for DS1 access on a DS3XM card.
Note•This command is not allowed if the card is a protect card.
•Both the MODE and FMT fields of this command apply to the DS3XM-12 card only.
•For the DS3XM-12 card, the DS1 frame format NE default is AUTO_PROV_FMT for the first 30 seconds to determine the real format. After 30 seconds, the DS1 frame format will be detected as FRAMED. If the frame format is not detected, it will be in the UNFRAMED format.
•For preprovisioning the DS3XM-12 card, the DS1 frame format defaults to UNFRAMED.
•For the DS3XM-12 card, the DS1 configurable attributes (PM, TH, alarm, etc.) only apply on the ported ports (1-12) and the VT-mapped (odd) portless ports in xxx-xxx-DS1 commands. If you provision or retrieve DS1 attributes on the DS3-mapped (even) portless port in xxx-xxx-DS1 commands, an error message will be returned.
•The test set physical connection set up through ED-T3/DS1/STS1/VT1 of the DS3XM-12 card is only allowed on the physical front ports (PORTED ports, ports 1-12), which are the monitoring ports.
–The monitoring test access ports follow the common rules for the other cards. For example, ED-T3 on port 2 (FAC-6-2) with a TACC number (8), the next port, port 3 (FAC-6-3) is used as the monitoring point also. The RTRV-T3 on both port-2 and port-3 return the same TACC number (8) being used to monitor the cross-connection end (A-B). The last port (port 12) is not allowed to set up a physical connection with the test set because there is no next available port to be the monitoring port.
–The TACC disconnection (DISC-TACC) and the test access mode change command (CHG-TACC) follow the same requirement as in the step above, but it is applied on the ported ports of the DS3XM-12 card.
–The test access connection set-up command (CONN-TACC) has monitored points, which can be portless ports. This command is applied on both ported and portless ports of the DS3XM-12 card.
•If the entity has a TACC connection, the entity is not allowed to have ported or portless STS/VT cross-connection (or circuit) provisioning on the DS3XM-12 card.
CategoryPorts
SecurityProvisioning
Related Commands
Input FormatED-DS1:[<TID>]:<AID>:<CTAG>:::[TACC=<TACC>],[TAPTYPE=<TAPTYPE>],
[MODE=<MODE>],[FMT=<FMT>];Input ExampleED-DS1:PETALUMA:DS1-2-1-6-12:123:::TACC=8,TAPTYPE=DUAL,MODE=FDL,FMT=ESF;
Input Parameters
Table 11-15 ED-DS1 Input Parameters
Parameter and Values DescriptionAID
Access identifier from the "DS1" section
TACC
TAP number within a range of 0 to 999. Indicates whether the digroup being provisioned is to be used as a test access digroup. When TACC is 0 (zero), the TAP is deleted. Integer
TAPTYPE
TAP type
Parameter type is TAPTYPE—test access point type
•DUAL
Dual FAD
•SINGLE
Single FAD
MODE
Mode with which the command is to be implemented. DS1 path mode of the DS3XM-12 card. Defaults to FDL
Parameter type is DS1MODE—the DS1 path mode of the DS3XM-12 card
•ATT
The DS1 path of the DS3XM-12 card is in AT&T 54016 mode
•FDL
The DS1 path of the DS3XM-12 card is in FDL T1-403 mode
FMT
Digital signal format. The DS1 path frame format of the DS3XM-12 card. Defaults to UNFRAMED
Parameter type is FRAME_FORMAT—frame format for a T1 port
•D4
Frame format is D4
•ESF
Frame format is ESF
•UNFRAMED
Frame format is unframed
11.16 ED-EC1
Edit Electrical Carrier
Usage Guidelines
Cisco ONS 15454, ONS 15310-CL
This command edits the attributes of an EC1.
Note This command is not allowed if the card is a protecting card.
CategoryPorts
SecurityProvisioning
Related Commands
Input FormatED-EC1:[<TID>]:<AID>:<CTAG>:::[PJMON=<PJMON>],[LBO=<LBO>],[SOAK=<SOAK>],
[SFBER=<SFBER>],[SDBER=<SDBER>],[NAME=<NAME>],[EXPTRC=<EXPTRC>],
[TRC=<TRC>],[TRCMODE=<TRCMODE>],[<TRCFORMAT>],[AISONLPBK=<AISONLPBK>],
[CMDMDE=<CMDMDE>]:[<PST>[,<SST>]];Input ExampleED-EC1:CISCO:FAC-1-1:123:::PJMON=0,LBO=0-225,SOAK=10,SFBER=1E-4,SDBER=1E-6,
NAME="EC1 PORT",EXPTRC="AAA",TRC="AAA",TRCMODE=MAN,TRCFORMAT="16-BYTE,
AISONLPBK=AIS_ON_LPBK_ALL,CMDMDE=CMDMDE:IS,AINS;Input Parameters
Table 11-16 ED-EC1 Input Parameters
Parameter and Values DescriptionAID
Access identifier from the "FACILITY" section
PJMON
A SONET pointer number (0 or 1) of an EC1 port. Integer. Defaults to 0
LBO
Line build out settings. Integer. Defaults to 0-225
Parameter type is E_LBO—electrical signal line buildout
•0-225
Electrical signal line buildout range is 0-225
•226-450
Electrical signal line buildout range is 226-450
SOAK
IS-AINS to IS transition soak time as measured in 15-minute intervals. A value of 4 equals a soak time of 1 hour. The allowable range is 0 to 192 intervals (maximum of 48 hours). Integer. Defaults to 32
SFBER
Signal failure threshold. Defaults to 1E-4
Parameter type is SF_BER—the threshold for declaring signal failure on a facility or path
•1E-3
SFBER is 1E-3
•1E-4
SFBER is 1E-4
•1E-5
SFBER is 1E-5
SDBER
Signal degrade threshold. Defaults to 1E-7
Parameter type is SD_BER—the threshold for declaring signal degrade on a facility or path
•1E-5
SDBER is 1E-5
•1E-6
SDBER is 1E-6
•1E-7
SDBER is 1E-7
•1E-8
SDBER is 1E-8
•1E-9
SDBER is 1E-9
NAME
String. Default value is NULL. Maximum length is 32 characters
EXPTRC
String
TRC
String
TRCMODE
Trace mode
Parameter type is TRCMODE—trace mode
•AUTO
Use the previously received path trace string as the expected string. Not applicable to MXP/TXP cards
•AUTO-NO-AIS
Use the previously received path trace string as the expected string and do not turn on AIS and RDI if TIMP is detected
•MAN
Use the provisioned expected string as the expected string
•MAN-NO-AIS
Use the provisioned expected string as the expected string and do not turn on AIS and RDI if TIMP is detected
•OFF
Turn off path trace capability. Nothing will be reported
TRCFORMAT
Trace message size
Parameter type is TRCFORMAT—trace format
•1-BYTE
1 byte trace message
•16-BYTE
16 byte trace message
•64-BYTE
64 byte trace message
•Y
Enable an attribute
AISONLPBK
Defaults to AIS_ONLPBK_FACILITY
Parameter type is AIS_ON_LPBK—Indicates if AIS is sent on a loopback
•AIS_ONLPBK_FACILITY
AIS is sent on facility loopbacks
•AIS_ON_LPBK_ALL
AIS is sent on all loopbacks
•AIS_ON_LPBK_OFF
AIS is not sent on loopbacks
•AIS_ON_LPBK_TERMINAL
AIS is sent on terminal loopbacks
CMDMDE
Command Mode. Defaults to NORM
Parameter type is CMDMDE—forces the system to execute a given command regardless of any standing conditions. Normal mode is the default behavior for all commands but you can specify FRCD to force the system to override a state where the command would normally be denied
•FRCD
Force the system to override a state where the command would normally be denied
•NORM
Execute the command normally. Do not override any conditions that might make the command fail
PST
Primary state. Defaults to IS
Parameter type is PST—indicates the current overall service condition of an entity
•IS
In service
•OOS
Out of service
SST
Secondary state. Defaults to AINS
Parameter type is SST—provides additional information pertaining to PST and PSTQ
•AINS
Automatic in service
•DSBLD
Disabled
•LPBK
Loopback
•MEA
Mismatch of equipment and attributes
•MT
Maintenance mode
•OOG
Out of group
•SWDL
Software downloading
•UAS
Unassigned
•UEQ
Unequipped
11.17 ED-EQPT
Edit Equipment
Usage Guidelines
Cisco ONS 15454, ONS 15327, ONS 15600, ONS 15310-CL
This command edits the attributes for a given equipment slot in the NE. If the card is in an equipment slot, this command is allowed only on the working AID.
Note The ONS 15600 only supports these parameters: TID, AID, CTAG, PST and SST.
The PROTID parameter indicates the unique identifier of the protection group (the protect card). "NULL" is a special value of the PROTID parameter and indicates absence of a protection group. For the 1:1 protection type, RVRTV and RVTM parameters can be changed. For the 1:1 protection type, if the PROTID parameter is entered as "NULL", the protection group is deleted.
ED-EQPT:[<TID>]:SLOT-2:<CTAG>:::PROTID=NULL;
For the 1:N protection type, if the PROTID is "NULL", the AIDs in the list are removed from the protection group. If all the working cards are in the AID list, the protection group is deleted.
Example: if Slot-1, Slot-2 and Slot-4 were the only working cards in the protection group. The following command will remove Slot-4 from the protection group:
ED-EQPT:[<TID>]:SLOT-4:<CTAG>:::PROTID=NULL;
The protection group still has Slot-1 and Slot-2 as working cards.
The following command will remove all the other working cards in the above example and consequently, delete the protection group itself:
ED-EQPT:[<TID>]:SLOT-2&SLOT-1:<CTAG>:::PROTID=NULL;
The ED-EQPT command can be successfully executed on an already provisioned card to add or remove a working card from a protection group. This command is not valid on a protect card. Only cards can be added to or removed from a protection group. Protection type is immutable and is determined at the time of creation of a protection group (while adding the first working card). Once provisioned, the equipment type cannot be edited either.
Examples of adding an existing card to a protection group using the ED-EQPT command:
1:1 protection group
ED-EQPT::SLOT-2:12:::PROTID=SLOT-1,RVRTV=Y,RVTM=9.0;
1:N protection group
ED-EQPT::SLOT-2:12:::PROTID=SLOT-3,PRTYPE=1-N,RVTM=6.5;
Error conditions for editing a 1:1 or 1:N protection group might be:
1. Editing the PRTYPE or PROTID (non-NULL value) parameters.
2. Editing RVRTV or RVTM when no protection group exists.
3. Editing RVRTV for 1:N protection.
4. Failed to remove, currently switched to protect.
5. The CARDMODE provisioning is allowed on the DS3XM-12 and ML-Series cards
a. The DS3XM's provisioning is based on the XCON type and DS3XM-12's location. For example:
The DS3XM-12 card in the lower speed I/O slot with the XCVT/XC10G card only allows the DS3XM-12-STS12 CARDMODE. Other cases allow the CARDMODE to be DS3XM-12-STS-48
b. There is no card reboot if the CARDMODE is changed on the DS3XM-12 card.
c. The DS3XM-12 card can be upgraded or downgraded by changing the CARDMODE with the ED-EQPT command.
6. If the command mode (CMDMDE) is set to forced (FRCD) during the creation of a 1:1 or 1:N protection group, all cards must be physically plugged in and in the service state (IS). If the cards are not physically plugged in, then the command is denied with an appropriate error message. When the command mode is set to normal (NORM) (which is the default) the cards do not have to be physically plugged in and in the service state.
7. If the command mode is set to forced (FRCD) during the removal of a card in a 1:1 or 1:N protection group, there must be no cross-connects (for example, services) present on the card. If there are cross-connects present on the card, the command is denied with an appropriate error message. If the command mode is set to normal (NORM) (which is the default), it does not require that cross-connects be deleted on the card.
Note For the FC_MR-4 card, the card mode cannot be changed to FCMR-LINERATE when the payload on any port is 1GFICON or 2GFICON. These payloads are allowed only in distance extension card mode.
CategoryEquipment
SecurityProvisioning
Related Commands
Input FormatED-EQPT:[<TID>]:<AID>:<CTAG>:::[PROTID=<PROTID>],[PRTYPE=<PRTYPE>],
[RVRTV=<RVRTV>],[RVTM=<RVTM>],[CMDMDE=<CMDMDE>],
[CARDMODE=<CARDMODE>],[PEERID=<PEERID>],[REGENNAME=<REGENNAME>],
[PWL=<PWL>],[RETIME=<RETIME>]:[<PST>[,<SST>]];Input ExampleED-EQPT:CISCO:SLOT-2:123:::PROTID=SLOT-1,PRTYPE=1-1,RVRTV=Y,RVTM=9.0,
CMDMDE=FRCD,CARDMODE=DS3XM12-STS48,PEERID=SLOT-2,
REGENNAME="THIS GROUP",PWL=1530.33,RETIME=Y:OOS,MT;Input Parameters
Table 11-17 ED-EQPT Input Parameters
Parameter and Values DescriptionAID
Access identifier from the "EQPT" section
PROTID
Protecting card slot number of the protection group from the "PRSLOT" section
PRTYPE
Protection group type
Parameter type is PROTECTION_GROUP—protection group type
•1-1
1 for 1 protection group
•1-N
1 for N protection group
RVRTV
Revertive mode. The value Y indicates that the protection switching system reverts service to the original line after restoration. The value N indicates that the protection switching system does not revert service to the original line after restoration. RVRTV is applicable only for 1+1 protection switching. Null defaults to N
Parameter type is ON_OFF—disable or enable an attribute
•N
Disable an attribute
•Y
Enable an attribute
RVTM
Revertive time
Parameter type is REVERTIVE_TIME—revertive time
•0.5 to 12.0
Revertive time is 0.5 to 12.0 minutes
CMDMDE
Command mode. Only applicable when creating or deleting a protection group (1:1 or 1:N) and/or adding cards to an existing protection group (1:N). Default is NORM. If creating or adding cards to a protection group, specifying FRCD requires the card to be physically plugged in and in the service state (IS). If removing cards from a protection group (1:N) or deleting the protection group (1:1, 1:N), specifying FRCD requires that there are no cross-connects (services) on the card
Parameter type is CMDMDE—forces the system to execute a given command regardless of any standing conditions. Normal mode is the default behavior for all commands but you can specify FRCD to force the system to override a state where the command would normally be denied
•FRCD
Force the system to override a state where the command would normally be denied
•NORM
Execute the command normally. Do not override any conditions that might make the command fail
CARDMODE
Card mode
Note The card will reboot after the mode changes so the mode change request will not go through if all the ports on the card are not in OOS mode.
TL1 will not set a default CARD_MODE value at the management interface level if no PWL value is given
Parameter type is CARDMODE—card mode. Card mode is applicable to cards that have multiple capabilities, for example, the ML card can operate in two distinct modes: Linear Mapper Mode and L2/L3 Mode
•DS3XM12-STS12
The DS3XM-12 card in the STS12 back plane rate mode
•DS3XM12-STS48
The DS3XM-12 card in the STS48 back plane rate mode
•DWDM-LINE
Line terminating mode
•DWDM-SEC
Section terminating mode
•DWDM-TRANS-AIS
Transparent mode AIS
•DWDM-TRANS-SQUELCH
Transparent mode SQUELCH
•FCMR-DISTEXTN
FC_MR-4 card with distance extension support
•FCMR-LINERATE
FC_MR-4 card without distance extension support
•ML-GFP
ML-Series card in DOS FPGA using GFP framing type
•ML-HDLC
ML-Series card in DOS FPGA using HDLC framing type
•MXPMR25G-FCGE
Fibre channel or GIGE mode for the MXP-MR-2.5G card
PEERID
The regeneration peer slot from the "EQPT" section
REGENNAME
The name of a regeneration group. String
PWL
Provisioned wavelength. TL1 will not set a default PWL value at the management level if no PWL value is given
Parameter type is OPTICAL_WLEN—optical wavelength
•1530.33
Wavelength 1
•1531.12
Wavelength 2
•1531.90
Wavelength 3
•1532.68
Wavelength 4
•1534.25
Wavelength 5
•1535.04
Wavelength 6
•1535.82
Wavelength 7
•1536.61
Wavelength 8
•1538.19
Wavelength 9
•1538.98
Wavelength 10
•1539.77
Wavelength 11
•1540.56
Wavelength 12
•1542.14
Wavelength 13
•1542.94
Wavelength 14
•1543.73
Wavelength 15
•1544.53
Wavelength 16
•1546.12
Wavelength 17
•1546.92
Wavelength 18
•1547.72
Wavelength 19
•1548.51
Wavelength 20
•1550.12
Wavelength 21
•1550.92
Wavelength 22
•1551.72
Wavelength 23
•1552.52
Wavelength 24
•1554.13
Wavelength 25
•1554.94
Wavelength 26
•1555.75
Wavelength 27
•1556.55
Wavelength 28
•1558.17
Wavelength 29
•1558.98
Wavelength 30
•1559.79
Wavelength 31
•1560.61
Wavelength 32
•USE-TWL1
Use Tunable Wavelength 1
RETIME
Indicates if retiming is needed. Applicable only to the DS1-E1-56 card (ONS 15454)
Parameter type is YES_NO—whether the user's password is about to expire, the user is logged into the NE, or the user is locked out of the NE
•NO
No
•YES
Yes
PST
Primary state
Parameter type is PST—indicates the current overall service condition of an entity
•IS
In service
•OOS
Out of service
SST
Secondary state
Parameter type is SST—provides additional information pertaining to PST and PSTQ
•AINS
Automatic in service
•DSBLD
Disabled
•LPBK
Loopback
•MEA
Mismatch of equipment and attributes
•MT
Maintenance mode
•OOG
Out of group
•SWDL
Software downloading
•UAS
Unassigned
•UEQ
Unequipped
11.18 ED-FAC
Edit Facility
Usage Guidelines
Cisco ONS 15454, ONS 15327, ONS 15600, ONS 15310-CL
This command provisions the payload (or signal) type of facility. The default values for all optional parameters are NE default values. These values might not be the current value for a parameter. In order to obtain the current value, issue the RTRV-XX command to retrieve them.
CategoryPorts
SecurityProvisioning
Related Commands
Input FormatED-FAC:[<TID>]:<SRC>:<CTAG>:::[PAYLOAD=<PAYLOAD>],
[CMDMDE=<CMDMDE>]:[<PST>[,<SST>]];Input ExampleED-FAC:CISCO:FAC-3-9:2222:::PAYLOAD=E4-FRAMED,CMDMDE=CMDMDE:IS,AINS;
Input Parameters
Table 11-18 ED-FAC Input Parameters
Parameter and Values DescriptionSRC
Source access identifier from the "FACILITY" section
PAYLOAD
The payload for the card
Parameter type is PAYLOAD—identifies payload type
•10GFC
10 Gigabit Ethernet Fibre Channel mode
•10GIGE
10 Gigabit Ethernet
•1GFC
1 Gigabit Fibre Channel mode
•1GFICON
1 Gigabit FICON mode
•2GFC
2 Gigabit Fibre Channel mode
•2GFICON
2 Gigabit FICON mode
•DS3
DS3 mode
•DV6000
Video mode
•EC1
EC1 mode
•ESCON
ESCON mode
•ETRCLO
ETR/CLO payload mode
•GIGE
Gigabit Ethernet Payload
•HDTV
HDTV mode
•ISC1
ISC1 Mode
•ISC3
ISC3 Mode
•OC12
SONET OC-12 mode
•OC3
SONET OC-3 mode
•OC48
SONET OC-48 mode
•PASS-THROUGH
Pass through mode
•SDI-D1-VIDEO
SDI-D1-Video mode
•SONET
SONET Payload Mode
CMDMDE
Command Mode. Defaults to NORM
Parameter type is CMDMDE—forces the system to execute a given command regardless of any standing conditions. Normal mode is the default behavior for all commands but you can specify FRCD to force the system to override a state where the command would normally be denied
•FRCD
Force the system to override a state where the command would normally be denied
•NORM
Execute the command normally. Do not override any conditions that might make the command fail
PST
Primary state. Defaults to IS
Parameter type is PST—indicates the current overall service condition of an entity
•IS
In service
•OOS
Out of service
SST
Secondary state. Defaults to AINS
Parameter type is SST—provides additional information pertaining to PST and PSTQ
•AINS
Automatic in service
•DSBLD
Disabled
•LPBK
Loopback
•MEA
Mismatch of equipment and attributes
•MT
Maintenance mode
•OOG
Out of group
•SWDL
Software downloading
•UAS
Unassigned
•UEQ
Unequipped
11.19 ED-FFP-<MOD2DWDMPAYLOAD>
Edit Facility Protection Group (10GFC, 10GIGE, 1GFC, 1GFICON, 2GFC, 2GFICON, D1VIDEO, DV6000, ETRCLO, GIGE, HDTV, ISC1)
Usage Guidelines
Cisco ONS 15454
This command edits a Y-cable protection group on client facilities.
CategoryDWDM
SecurityProvisioning
Related Commands
Input FormatED-FFP-<MOD2DWDMPAYLOAD>:[<TID>]:<AID>:<CTAG>:::[PROTID=<PROTID>],
[RVRTV=<RVRTV>],[RVTM=<RVTM>],[PSDIRN=<PSDIRN>][:];Input ExampleED-FFP-CLNT:CISCO:FAC-1-1:100:::PROTID=DC-METRO,RVRTV=N,RVTM=1.0,PSDIRN=BI;
Input Parameters
Table 11-19 ED-FFP-<MOD2DWDMPAYLOAD> Input Parameters
Parameter and Values DescriptionAID
Access identifier from the "FACILITY" section
PROTAID
The protection group identifier (protection group name). Defaults to the protecting port AID of the protection group. PROTAID can have a maximum length of 32 characters. String
RVRTV
Revertive mode. The value Y indicates that the protection switching system reverts service to the original line after restoration. The value N indicates that the protection switching system does not revert service to the original line after restoration. RVRTV is applicable only for 1+1 protection switching. Null defaults to N. Only applies to path protection
Parameter type is ON_OFF—disable or enable an attribute
•N
Disable an attribute
•Y
Enable an attribute
RVTM
Revertive time. RVTM is not allowed to be set while "RVRTV" is N. Only applies to path protection
Parameter type is REVERTIVE_TIME—revertive time
•0.5 to 12.0
Revertive time is 0.5 to 12.0 minutes
PSDIRN
Protection switch operation. Identifies the switching mode. Defaults to UNI.
Note The MXP_2.5G_10G and TXP_MR_10G cards do not support BI-DIRECTIONAL switching
Parameter type is UNI_BI—unidirectional switch operations
•BI
Bidirectional protection switching
•UNI
Unidirectional protection switching
11.20 ED-FFP-<OCN_TYPE>
Edit Facility Protection Group (OC3, OC12, OC48, OC192)
Usage Guidelines
Cisco ONS 15454, ONS 15327, ONS 15600, ONS 15310-CL
See Table 27-1 for supported modifiers by platform.
This command edits the optical facility protection.
Note•This command can be used on both protecting and working AIDs. Optimized 1+1 and related attributes are only applicable to the ONS 15454.
•Optimized 1+1 and related attributes are only applicable to ONS 15454.
•The default values for all optional parameters are NE default values. These values might not be the current value for a parameter. In order to obtain the current value, issue the RTRV-XX command to retrieve them.
CategoryProtection
SecurityProvisioning
Related Commands
Input FormatED-FFP-<OCN_TYPE>:[<TID>]:<AID>:<CTAG>:::[PROTID=<PROTID>],
[RVRTV=<RVRTV>],[RVTM=<RVTM>],[PSDIRN=<PSDIRN>],[VRGRDTM=<VRGRDTM>],
[DTGRDTM=<DTGRDTM>],[RCGRDTM=<RCGRDTM>][:];Input ExampleED-FFP-OC3:PETALUMA:FAC-1-1:1:::PROTID=PROT_NAME,RVRTV=Y,RVTM=1.0,
PSDIRN=BI,VRGRDTM=0.5,DTGRDTM=1.0,RCGRDTM=1.0;Input Parameters
Table 11-20 ED-FFP-<OCN_TYPE> Input Parameters
Parameter and Values DescriptionAID
Access identifier from the "FACILITY" section
PROTAID
The protection group identifier (protection group name). PROTAID can have a maximum length of 32 characters. String
RVRTV
Revertive mode. The value Y indicates that the protection switching system reverts service to the original line after restoration. The value N indicates that the protection switching system does not revert service to the original line after restoration. RVRTV is applicable only for 1+1 protection switching. Null defaults to N
Parameter type is ON_OFF—disable or enable an attribute
•N
Disable an attribute
•Y
Enable an attribute
RVTM
Revertive time
Parameter type is REVERTIVE_TIME—revertive time
•0.5 to 12.0
Revertive time is 0.5 to 12.0 minutes
PSDIRN
Protection switch operation. Indicates the switch mode. Defaults to UNI
Parameter type is UNI_BI—unidirectional and bidirectional switch operations
•BI
Bidirectional protection switching
•UNI
Unidirectional protection switching
VRGRDTM
Verification guard timer. Only applicable to optimized 1+1
Parameter type is VERIFICATION_GUARD_TIMER—optimized 1+1 verification guard timer
•0.5
500 ms
•1.0
1 second
DTGRDTM
Detection guard timer. Only applicable to optimized 1+1
Parameter type is DETECTION _GUARD_TIMER—optimized 1+1 detection guard timer
•0.0
0 seconds
•0.05
50 ms
•0.1
100 ms
•0.5
500 ms
•1.0 to 5.0
1 second to 5 seconds
RCGRDTM
Recovery guard timer. Only applicable to optimized 1+1
Parameter type is RECOVERY_GUARD_TIMER—optimized 1+1 recovery guard timer
•0.0
0 seconds
•0.05
50 ms
•0.1
100 ms
•0.5
500 ms
•1.0 to 10.0
1 second to 10 seconds
11.21 ED-FFP-OCH
Edit Facility Protection Group Optical Channel
Usage Guidelines
Cisco ONS 15454
This command changes the provisioning for the default protection group on the DWDM port of a TXP_MR_2.5G and TXPP_MR_2.5G card.
CategoryDWDM
SecurityProvisioning
Related Commands
Input FormatED-FFP-OCH:[<TID>]:<AID>:<CTAG>:::[PROTID=<PROTID>],[RVRTV=<RVRTV>],
[RVTM=<RVTM>],[PSDIRN=<PSDIRN>][:];Input ExampleED-FFP-OCH:VA454-22:CHAN-2-2:100:::PROTID="FIXEDPROTECTION",RVRTV=N,
RVTM=1.0,PSDIRN=BI;Input Parameters
Table 11-21 ED-FFP-OCH Input Parameters
Parameter and Values DescriptionAID
Access identifier from the "CHANNEL" section
PROTAID
The protection group identifier (protection group name). String
RVRTV
Revertive mode. The value Y indicates that the protection switching system reverts service to the original line after restoration. The value N indicates that the protection switching system does not revert service to the original line after restoration. RVRTV is applicable only for 1+1 protection switching. Null defaults to N
Parameter type is ON_OFF—disable or enable an attribute
•N
Disable an attribute
•Y
Enable an attribute
RVTM
Revertive time
Parameter type is REVERTIVE_TIME—revertive time
•0.5 to 12.0
Revertive time is 0.5 to 12.0 minutes
PSDIRN
Protection switch operation
Parameter type is TRANS_MODE—G1000 transponder mode
•BI
Bidirectional
•NONE
Not in transponder mode
•UNI
Unidirectional
11.22 ED-FSTE
Edit Fast Ethernet
Usage Guidelines
Cisco ONS 15454, ONS 15310-CL
This command edits the front end port information of the fast (10/100 Mbps) Ethernet card.
The default values for all optional parameters are NE default values. These values might not be the current value for a parameter. In order to obtain the current value, issue the RTRV-XX command to retrieve them.
Note For the ML-100T-8 card, only the NAME parameter can be set.
CategoryPorts
SecurityProvisioning
Related Commands
Input FormatED-FSTE:[<TID>]:<AID>:<CTAG>:::[FLOW=<FLOW>],[EXPDUPLEX=<EXPDUPLEX>],
[EXPSPEED=<EXPSPEED>],[VLANCOS=<VLANCOS>],[IPTOS=<IPTOS>],
[NAME=<NAME>],[CMDMDE=<CMDMDE>],[SOAK=<SOAK>]:[<PST>[,<SST>]];Input ExampleED-FSTE:CISCO:FAC-1-1:123:::FLOW=FLOW,EXPDUPLEX=EXPDUPLEX,
EXPSPEED=EXPSPEED, VLANCOS=VLANCOS,IPTOS=IPTOS,
NAME="FSTE PORT",CMDMDE=CMDMDE,SOAK=32:IS,AINS;Input Parameters
Table 11-22 ED-FSTE Input Parameters
Parameter and Values DescriptionAID
Access identifier from the "FACILITY" section
FLOW
Flow control
Parameter type is ON_OFF—disable or enable an attribute
•N
Disable an attribute
•Y
Enable an attribute
EXPDUPLEX
Ethernet duplex mode
Parameter type is ETHER_DUPLEX—duplex mode
•AUTO
Auto mode
•FULL
Full mode
•HALF
Half mode
EXPSPEED
Ethernet speed
Parameter type is ETHER_SPEED—Ethernet speed
•100_MBPS
100 Mbps
•10_GBPS
10 Gbps
•10_MBPS
10 Mbps
•1_GBPS
1 Gbps
•AUTO
Auto
VLANCOS
Priority queuing threshold based on VLAN class of service of incoming Ethernet packets. Default value is 1175. Integer
IPTOS
Priority queuing threshold based on IP type of service of incoming Ethernet packets. Default value is 368. Integer
NAME
Name. String
CMDMDE
Command Mode. The FRCD mode of operation is applicable to delete a VCAT member cross-connect from IS-NR or OOS-AU,AINS service state
Parameter type is CMDMDE—forces the system to execute a given command regardless of any standing conditions. Normal mode is the default behavior for all commands but you can specify FRCD to force the system to override a state where the command would normally be denied
•FRCD
Force the system to override a state where the command would normally be denied
•NORM
Execute the command normally. Do not override any conditions that might make the command fail
SOAK
OOS-AINS to IS transition soak time as measured in 15 minute intervals, so a value of 4 translates to a soak time of 1 hour. The allowable range is 0 to 192 intervals (maximum of 48 hours). Integer
PST
Primary state
Parameter type is PST—indicates the current overall service condition of an entity
•IS
In service
•OOS
Out of service
SST
Secondary state
Parameter type is SST—provides additional information pertaining to PST and PSTQ
•AINS
Automatic in service
•DSBLD
Disabled
•LPBK
Loopback
•MEA
Mismatch of equipment and attributes
•MT
Maintenance mode
•OOG
Out of group
•SWDL
Software downloading
•UAS
Unassigned
•UEQ
Unequipped
11.23 ED-G1000
Edit G1000
Usage Guidelines
Cisco ONS 15454
This command edits the attributes related to a G1000 port.
The default values for all optional parameters are NE default values. These values might not be the current value for a parameter. In order to obtain the current value, issue the RTRV-XX command.
CategoryPorts
SecurityProvisioning
Related Commands
Input FormatED-G1000:[<TID>]:<AID>:<CTAG>:::[MFS=<MFS>],[FLOW=<FLOW>],
[LOWMRK=<LOWMRK>],[HIWMRK=<HIWMRK>],[AUTONEG=<AUTONEG>],
[NAME=<NAME>],[CMDMDE=<CMDMDE>],[SOAK=<SOAK>]:[<PST>[,<SST>]];Input ExampleED-G1000:TID:FAC-1-1:CTAG:::MFS=1548,FLOW=Y,LOWMRK=20,HIWMRK=492,
AUTONEG=Y,NAME="G1000 PORT",CMDMDE=FRCD,SOAK=32:OOS,DSBLD;Input Parameters
Table 11-23 ED-G1000 Input Parameters
Parameter and Values DescriptionAID
Access identifier from the "FACILITY" section
MFS
Maximum frame size
Parameter type is MFS_TYPE—maximum frame size used by an Ethernet card
•1548
Normal frame size
•JUMBO
Jumbo frame size
FLOW
Flow control
Parameter type is ON_OFF—disable or enable an attribute
•N
Disable an attribute
•Y
Enable an attribute
LOWMRK
Low watermark value. Integer. Defaults to 25. LOWMRK is available starting with Release 4.0.1
HIWMRK
High watermark value. Integer. Defaults to 485
AUTONEG
Automatic negotiation. Defaults to Y
Parameter type is ON_OFF—disable or enable an attribute
•N
Disable an attribute
•Y
Enable an attribute
NAME
Name. String. Default is NULL. Maximum length is 32 characters
CMDMDE
Command execution mode
Parameter type is CMDMDE—forces the system to execute a given command regardless of any standing conditions. Normal mode is the default behavior for all commands but you can specify FRCD to force the system to override a state where the command would normally be denied
•FRCD
Force the system to override a state where the command would normally be denied
•NORM
Execute the command normally. Do not override any conditions that might make the command fail
SOAK
OOS-AINS to IS transition soak time as measured in 15-minute intervals. A value of 4 equals a soak time of 1 hour. The allowable range is 0 to 192 intervals (maximum of 48 hours). Integer. Defaults to 32
ENCAP
Encapsulation. String
PST
Primary state. Defaults to OOS
Parameter type is PST—indicates the current overall service condition of an entity
•IS
In service
•OOS
Out of service
SST
Secondary state. Defaults to DSBLD
Parameter type is SST—provides additional information pertaining to PST and PSTQ
•AINS
Automatic in service
•DSBLD
Disabled
•LPBK
Loopback
•MEA
Mismatch of equipment and attributes
•MT
Maintenance mode
•OOG
Out of group
•SWDL
Software downloading
•UAS
Unassigned
•UEQ
Unequipped
11.24 ED-GFP
Edit Generic Framing Protocol
Usage Guidelines
Cisco ONS 15454, ONS 15310-CL, ONS 15600
This command applies to the ONS 15454 CE-100T-8 card, the ONS 15454 FC_MR-4 card, the ONS 15310-CL CE-100T-8 card and the ONS 15600 ASAP card.
Note•The ONS 15600 only supports these parameters: TID, AID, CTAG and FCS.
•This command does not apply to ONS 15310-CL ML-100T-8 card.
•For the FC_MR-4 card, the parameters AUTOTHGFPBUF, GFPBUF and FILTER can be edited only if distance extension is enabled (set to B2B).
CategoryPorts
SecurityProvisioning
Related Commands
Input FormatED-GFP:[<TID>]:<AID>:<CTAG>:::[FCS=<FCS>],[AUTOTHGFPBUF=<AUTOTHGFPBUF>],
[GFPBUF=<GFPBUF>],[FILTER=<FILTER>];Input ExampleED-GFP:CISCO:VFAC-1-0:123:::FCS=N,AUTOTHGFPBUF=Y,GFPBUF=16,FILTER=EGRESS;
Input Parameters
Table 11-24 ED-GFP Input Parameters
Parameter and Values DescriptionAID
Access identifier from the "FACILITY" section.
Note VFAC AID is used for the CE-100T-8 cards on ONS 15310-CL and ONS 15454 and ASAP cards on ONS 15600. ML-100T-8 GFP management is done through the Cisco IOS CLI and not through the TL1 interface. FAC AID is used for ONS 15454 FC_MR-4
FCS
Payload frame check sequence
Parameter type is FCS—frame check sequence
•FCS-16
Frame check sequencing using 16 bits
•FCS-32
Frame check sequencing using 32 bits
•NONE
No frame check sequence
AUTOTHGFPBUF
Parameter type is ON_OFF—disable or enable an attribute
•N
Disable an attribute
•Y
Enable an attribute
FILTER
Parameter type is GFP_FILTER—filter feature in GFP
•EGRESS
Activate filter feature on egress port
•NONE
Turn off filter feature
11.25 ED-HDLC
Edit High-Level Data Link Control
Usage Guidelines
Cisco ONS 15600
This command edits HDLC-related attributes for HDLC-encapsulated payloads.
CategoryPorts
SecurityProvisioning
Related Commands
Input FormatED-HDLC:[<TID>]:<SRC>:<CTAG>[:::FCS=<FCS>];
Input ExampleED-HDLC:TID:VFAC-SLOT-PORT:CTAG:::FCS=FCS-16;
Input Parameters
Table 11-25 ED-HDLC Input Parameters
Parameter and Values DescriptionSRC
Access identifier from the "FACILITY" section. The ONS 15600 ASAP card uses the VFAC AID
FCS
Payload frame check sequence
Parameter type is FCS—frame check sequence
•FCS-16
Frame check sequence using 16 bits
•FCS-32
Frame check sequence using 32 bits
•NONE
No frame check sequence
11.26 ED-LNK-<MOD2O>
Edit Link (OCH, OMS, OTS)
Usage Guidelines
Cisco ONS 15454
This command edits an optical link state.
CategoryDWDM
SecurityProvisioning
Related Commands
Input FormatED-LNK-<MOD2O>:[<TID>]:<FROM>,
<TO>:<CTAG>:::[CMDMDE=<CMDMDE>]:[<PST>[,<SST>]];Input ExampleED-LNK-OMS:PENNGROVE:BAND-6-1-TX,BAND-13-1-RX:114:::CMDMDE=CMDMDE:IS,
AINS;Input Parameters
Table 11-26 ED-LNK-<MODO> Input Parameters
Parameter and Values DescriptionFROM
Identifier at one end of the optical link from the "BAND" section
TO
Identifier at the other end of the optical link from the "BAND" section
CMDMDE
Command Mode. The FRCD mode of operation is applicable to delete a VCAT member cross-connect from IS-NR or OOS-AU,AINS service state
Parameter type is CMDMDE—forces the system to execute a given command regardless of any standing conditions. Normal mode is the default behavior for all commands but you can specify FRCD to force the system to override a state where the command would normally be denied
•FRCD
Force the system to override a state where the command would normally be denied
•NORM
Execute the command normally. Do not override any conditions that might make the command fail
PST
Primary state
Note PST is not supported for OCH provisioning
Parameter type is PST—indicates the current overall service condition of an entity
•IS
In service
•OOS
Out of service
SST
Secondary state
Note SST is not supported for OCH provisioning
Parameter type is SST—provides additional information pertaining to PST and PSTQ
•AINS
Automatic in service
•DSBLD
Disabled
•LPBK
Loopback
•MEA
Mismatch of equipment and attributes
•MT
Maintenance mode
•OOG
Out of group
•SWDL
Software downloading
•UAS
Unassigned
•UEQ
Unequipped
11.27 ED-LNKTERM
Edit Provisionable Patchcord Termination
Usage Guidelines
Cisco ONS 15454, ONS 15327, ONS 15310-CL
This command edits the attributes of a provisionable patchcord that has already been created. Only the remote end attributes (REMOTENODE, REMOTELNKTERMID) can be edited.
Note•No two provisionable patchcord terminations on a node can have the same remote end link termination information. An attempt to modify an existing provisionable patchcord termination while not following the above restriction will lead to an error message being responsed.
•If the provisionable patchcord termination does not exist, an error message will be responsed.
•This command does not accept multiple and ALL AIDs.
•REMOTENODE is a string with a maximum length of 20 characters.
CategoryProvisionable Patchcords
SecurityProvisioning
Related Commands
Input FormatED-LNKTERM:[<TID>]:<AID>:<CTAG>:::[REMOTENODE=<REMOTENODE>],
[REMOTELNKTERMID=<REMOTELNKTERMID>];Input ExampleED-LNKTERM::LNKTERM-1:CTAG:::REMOTENODE=172.20.208.226,
REMOTELNKTERMID=25;Input Parameters
Table 11-27 ED-LNKTERM Input Parameters
Parameter and Values DescriptionAID
Access identifier from the "LNKTERM" section. Indicates a link (provisionable patchcord) termination on the local node
REMOTENODE
The node where the other end of the provisionable patchcord resides. This can be an IP address or a valid TID. Defaults to the IP address of the local node/existing value. String
REMOTELNKTERMID
The corresponding provisionable patchcord termination on the remote node (as specified by the REMOTENODE parameter). Integer value within the range of 1 to 65535. Defaults to existing value
11.28 ED-NE-GEN
Edit Network Element General
Usage Guidelines
Cisco ONS 15454, ONS 15327, ONS 15600, ONS 15310-CL
This command edits the node attributes of the NE.
Note•Only the IPADDR, IPMASK, DEFRTR, IIOP PORT and node name can be modified with this command.
•The node name can be a maximum of 20 characters. If the entered name exceeds 20 characters, an IPNV (Node Name Too Long) error message is returned.
•An existing NTP timing source can be removed by setting the address to 0.0.0.0.
•The maximum length of IPMASK is 18 characters. The default is the mask of the local IP address.
•ETHIPADDR and ETHIPMASK are disabled in this command. ETHIPADDR and ETHIPMASK are used to show the Ethernet interface address and mask. Both default to the nodes' IP address and masks.
Caution Changing the IPADDR, IPMASK, or IIOP Port will cause a reset of the controller card.
CategorySystem
SecuritySuperuser
Related Commands
Input FormatED-NE-GEN:[<TID>]::<CTAG>:::[NAME=<NAME>],[IPADDR=<IPADDR>],
[IPMASK=<IPMASK>],[DEFRTR=<DEFRTR>],[IIOPPORT=<IIOPPORT>],[NTP=<NTP>],
[ETHIPADDR=<ETHIPADDR>],[ETHIPMASK=<ETHIPMASK>],
[SUPPRESSIP=<SUPPRESSIP>];Input ExampleED-NE-GEN:CISCO::123:::NAME=NODENAME,IPADDR=192.168.100.52,
IPMASK=255.255.255.0,DEFRTR=192.168.100.1,IIOPPORT=57790,
NTP=192.168.100.52,ETHIPADDR=172.20.208.225,ETHIPMASK=255.255.255.0,
SUPPRESSIP=NO;Input Parameters
11.29 ED-NE-PATH
Edit Network Element Path
Usage Guidelines
Cisco ONS 15454, ONS 15327, ONS 15310-CL
This command edits the path attributes of the NE. The default value for an optional parameter is the NE default value.
CategorySystem
SecurityProvisioning
Related Commands
Input FormatED-NE-PATH:[<TID>]::<CTAG>:::[PDIP=<PDIP>],[XCMODE=<XCMODE>];
Input ExampleED-NE-PATH:::CTAG:::PDIP=Y,XCMODE=MIXED;
Input Parameters
11.30 ED-NE-SYNCN
Edit Network Element Synchronization
Usage Guidelines
Cisco ONS 15454, ONS 15327, ONS 15600, ONS 15310-CL
This command edits the synchronization attributes of the NE.
Note Although mixed mode timing is supported in this release, it is not recommended. Refer to the Cisco ONS SONET TL1 Reference Guide for more information.
Note The existing external and line modes have the same functionality in all ONS 15454 4.x and 5.x releases:
•External mode: the node derives its timing from the BITS inputs
•Line mode: the node derives its timing from the SONET line(s)
•Mixed mode: the node derives its timing from the BITS input or SONET lines
CategorySynchronization
SecurityProvisioning
Related Commands
Input FormatED-NE-SYNCN:[<TID>]::<CTAG>:::[TMMD=<TMMD>],[SSMGEN=<SSMGEN>],
[QRES=<QRES>],[RVRTV=<RVRTV>],[RVTM=<RVTM>];Input ExampleED-NE-SYNCN:CISCO::123:::TMMD=LINE,SSMGEN=GEN1,QRES=ABOVE-PRS,
RVRTV=Y,RVTM=8.0;Input Parameters
11.31 ED-OCH
Edit Optical Channel (OCH)
Usage Guidelines
Cisco ONS 15454
This command edits the attributes (service parameters) and state of an OCH facility.
Refer to the Cisco ONS SONET TL1 Reference Guide for specific card provisioning rules.
Note Primary=OOS and secondary=AINS states do not apply to Ethernet mode.
CategoryDWDM
SecurityProvisioning
Related Commands
Input FormatED-OCH:[<TID>]:<AID>:<CTAG>:::[RDIRN=<RDIRN>],[EXPWLEN=<EXPWLEN>],
[VOAATTN=<VOAATTN>],[VOAPWR=<VOAPWR>],[CALOPWR=<CALOPWR>],
[CHPOWER=<CHPOWER>],[NAME=<PORTNAME>],[SFBER=<SFBER>],[SDBER=<SDBER>],
[COMM=<COMM>],[GCCRATE=<GCCRATE>],[OSDBER=<OSDBER>],[DWRAP=<DWRAP>],
[FEC=<FEC>],[PAYLOADMAP=<PAYLOADMAP>],[MACADDR=<MACADDR>],
[SYNCMSG=<SYNCMSG>],[SENDDUS=<SENDDUS>],[SOAK=<SOAK>],[OSPF=<OSPF>],
[MFS=<MFS>],[CMDMDE=<CMDMDE>]:[<PST>[,<SST>]];Input ExampleED-OCH:CISCO:CHAN-6-2:114:::RDIRN=W-E,EXPWLEN=1530.32,VOAATTN=2.5,
VOAPWR=7.5,CALOPWR=0,CHPOWER=2.0,NAME="NYLINE",SFBER=1E-5,
SDBER=1E-6,COMM=DCC,GCCRATE=192K,OSDBER=1E-6,DWRAP=Y,FEC=STD,
PAYLOADMAP=ASYNCH,MACADDR=00-0E-AA-BB-CC-DD,SYNCMSG=N,
SENDDUS=Y,SOAK=10,OSPF=Y,MFS=2152,CMDMDE=CMDMDE:IS,AINS;Input Parameters
Table 11-31 ED-OCH Input Parameters
Parameter and Values DescriptionAID
Access identifier from the "CHANNEL" section
RDIRN
Ring directionality of the optical line
Parameter type is RDIRN_MODE—the optical ring directionality
•E-W
The direction of the signal is from east to west (clockwise)
•W-E
The direction of the signal is from west to east (counterclockwise)
EXPWLEN
Optical wavelength for this port. Applicable only to the following cards: optical service channel cards, optical amplifier cards, dispersion compensation units, multiplexer and demultiplexer cards and OADM cards
Parameter type is OPTICAL_WLEN—optical wavelength
•1530.33
Wavelength 1
•1531.12
Wavelength 2
•1531.90
Wavelength 3
•1532.68
Wavelength 4
•1534.25
Wavelength 5
•1535.04
Wavelength 6
•1535.82
Wavelength 7
•1536.61
Wavelength 8
•1538.19
Wavelength 9
•1538.98
Wavelength 10
•1539.77
Wavelength 11
•1540.56
Wavelength 12
•1542.14
Wavelength 13
•1542.94
Wavelength 14
•1543.73
Wavelength 15
•1544.53
Wavelength 16
•1546.12
Wavelength 17
•1546.92
Wavelength 18
•1547.72
Wavelength 19
•1548.51
Wavelength 20
•1550.12
Wavelength 21
•1550.92
Wavelength 22
•1551.72
Wavelength 23
•1552.52
Wavelength 24
•1554.13
Wavelength 25
•1554.94
Wavelength 26
•1555.75
Wavelength 27
•1556.55
Wavelength 28
•1558.17
Wavelength 29
•1558.98
Wavelength 30
•1559.79
Wavelength 31
•1560.61
Wavelength 32
•USE-TWL1
Use Tunable Wavelength 1
VOAATTN
The value of calibrated attenuation for the VOA. It is expressed in dBm. For the following cards: optical service channel, optical amplifier, dispersion compensation units, multiplexer and demultiplexer and OADM, the range is 0.0 to +30.0. Not supported for TXP or MXP cards. Float
VOAPWR
The value of calibrated output power that the VOA is going to set as a result of its attenuation. Applicable only to the following cards: optical service channel, optical amplifier, dispersion compensation units, multiplexer and demultiplexer and OADM. Float
CALOPWR
The value of the calibrated optical power expected for the line added to the calculated value which equals the total expected output power. Expressed in dBm. Applicable only to the following cards: optical service channel, optical amplifier, dispersion compensation units, multiplexer and demultiplexer and OADM. Defaults to 0 dBm. Float
CHPOWER
The value of per channel optical power expected to the OCH drop port of an AD-4C unit. CHPOWER is a float expressed in dBm
Parameter type is REVERTIVE_TIME—revertive time
•0.5 to 12.0
Revertive time is 0.5 to 12.0 minutes
PORTNAME
Port name. String
SFBER
Signal failure threshold for the SONET payload. Can only be provisioned on the working port
Parameter type is SF_BER—the threshold for declaring signal failure on a facility or path
•1E-3
SFBER is 1E-3
•1E-4
SFBER is 1E-4
•1E-5
SFBER is 1E-5
SDBER
Signal degrade threshold for the SONET payload. Can only be provisioned on the working port
Parameter type is SD_BER—the threshold for declaring signal degrade on a facility or path
•1E-5
SDBER is 1E-5
•1E-6
SDBER is 1E-6
•1E-7
SDBER is 1E-7
•1E-8
SDBER is 1E-8
•1E-9
SDBER is 1E-9
COMM
The GCC or DCC is enabled or disabled. The GCC can be enabled only if the digital wrapper has been enabled for the card. The default is NONE. Rules for an MXP_2.5G_10G/TXP_MR_10G client port are; only the DCC can be provisioned, if the termination mode is not transparent and the payload is SONET. On an MXP_2.5G_10G/TXP_MR_10G DWDM port, the DCC can be enabled only if the G.709 is not enabled and if the payload is SONET and the termination mode is not transparent. On an MXP_2.5G_10G/TXP_MR_10G DWDM port, the GCC can be enabled if there is no DCC and the G.709 flag is enabled. On a TXP/MXP DWDM port, the DCC/GCC can be disabled only if there are no provisionable patchcord terminations provisioned on the trunk port
Parameter type is COMM_TYPE—out of band communications channel termination type
•DCC
Section DCC type
•GCC
Generic communication channel (OTN) type
•NONE
Disable DCC or GCC if enabled
GCCRATE
The data rate of the GCC traffic. The default is 192 Kbps. For MXP_2.5G_10G/TXP_MR_10G cards this applies only to the DWDM port.
Note The 576K option is not supported for this release.
Parameter type is GCCRATE—the data rate of the GCC traffic
•192K
192 kbps
•576K
576 kbps
OSDBER
OTN SDBER. Can only be provisioned on the working port. Defaults to 1E-7
Parameter type is SD_BER—the threshold for declaring signal degrade on a facility or path
•1E-5
SDBER is 1E-5
•1E-6
SDBER is 1E-6
•1E-7
SDBER is 1E-7
•1E-8
SDBER is 1E-8
•1E-9
SDBER is 1E-9
DWRAP
The G.709 digital wrapper. It is either on or off. The system default is ON. For MXP_2.5G_10G/TXP_MR_10G cards, this applies only to the DWDM port.
To enable G.709:
•there should be no GCC on the DWDM port
•the payload (where the card is configured) should not be UNFRAMED
To disable G.709:
•there should be no GCC on the DWDM port
•the FEC should be turned to off
•there should be no overhead circuit created on the DWDM port
•none of the client ports on the card should be part of a Y-cable protection group (MXP only)
Parameter type is ON_OFF—disable or enable an attribute
•N
Disable an attribute
•Y
Enable an attribute
FEC
Forward error correction. It can be enabled only if the G.709 is turned ON. It is either off or enabled in standard or enhanced mode. The system default is standard FE enabled. The FEC level PM and thresholds apply if the FEC is turned ON
Parameter type is FEC_MODE—specifies the type of forward error correction
•ENH
Enhanced FEC is enabled
•OFF
FEC is disabled
•STD
Standard FEC is enabled
PAYLOADMAP
The type of payload mapping. It can be enabled only if the G.709 is turned ON and FEC is enabled
Parameter type is PAYLOAD_MAPPING—payload mapping mode
•ASYNCH
Asynchronous mapping mode
•ODU
ODU multiplex structure mode
•SYNCH
Synchronous mapping mode
MACADDR
MAC address for the 10GigE payload. String
SYNCMSG
The facility be enabled to provide the synchronization clock. This does not apply to the TXPD-10G card. This applies to an MXPD-10G card, only if the payload is SONET/SDH and the card termination mode is as follows:
TRANSPARENT - All Client ports are available for all timing selections. All Trunk ports are not available.
LINE - All ports are available for all-timing selectionsParameter type is ON_OFF—disable or enable an attribute
•N
Disable an attribute
•Y
Enable an attribute
SENDDUS
The facility sends out a Do not Use for Sync message. This does not apply to the TXPD-10G card. This applies to an MXPD-10G card, only if the payload is SONET/SDH and the card termination mode is as follows:
TRANSPARENT- All Client ports are available for all timing selections. All Trunk ports are not available.
LINE - All ports are available for all-timing selectionsParameter type is ON_OFF—disable or enable an attribute
•N
Disable an attribute
•Y
Enable an attribute
SOAK
OOS-AINS to IS transition soak time as measured in 15-minute intervals. A value of 4 equals a soak time of 1 hour. The allowable range is 0 to 192 intervals (maximum of 48 hours). Integer
OSPF
Open shortest path first
Parameter type is EXT_RING—indicates if the ring supports the extended K1/K2/K3 protocol
•N
The ring does not support the extended K1/K2/K3 protocol
•Y
The ring does support the extended K1/K2/K3 protocol
MFS
Integer
CMDMDE
Command mode
Parameter type is CMDMDE—forces the system to execute a given command regardless of any standing conditions. Normal mode is the default behavior for all commands but you can specify FRCD to force the system to override a state where the command would normally be denied
•FRCD
Force the system to override a state where the command would normally be denied
•NORM
Execute the command normally. Do not override any conditions that might make the command fail
PST
Primary state
Parameter type is PST—indicates the current overall service condition of an entity
•IS
In service
•OOS
Out of service
SST
Secondary state
Parameter type is SST—provides additional information pertaining to PST and PSTQ
•AINS
Automatic in service
•DSBLD
Disabled
•LPBK
Loopback
•MEA
Mismatch of equipment and attributes
•MT
Maintenance mode
•OOG
Out of group
•SWDL
Software downloading
•UAS
Unassigned
•UEQ
Unequipped
11.32 ED-OMS
Edit Optical Multiplex Section (OMS)
Usage Guidelines
Cisco ONS 15454
This command edits the attributes (service parameters) and state of an OMS facility.
CategoryDWDM
SecurityProvisioning
Related Commands
Input FormatED-OMS:[<TID>]:<AID>:<CTAG>:::[RDIRN=<RDIRN>],[EXPBAND=<EXPBAND>],
[VOAATTN=<VOAATTN>],[VOAPWR=<VOAPWR>],[CALOPWR=<CALOPWR>],
[CHPOWER=<CHPOWER>],[NAME=<NAME>],[SOAK=<SOAK>],
[CMDMDE=<CMDMDE>]:[<PST>[,<SST>]];Input ExampleED-OMS:PENNGROVE:BAND-6-1:114:::RDIRN=W-E,EXPBAND=1530.32-1532.68,
VOAATTN=2.5,VOAPWR=7.5,CALOPWR=0.0,CHPOWER=2.0,NAME="OMS PORT",
SOAK=8,CMDMDE=CMDMDE:IS,AINS;Input Parameters
Table 11-32 ED-OMS Input Parameters
Parameter and Values DescriptionAID
Access identifier from the "BAND" section
RDIRN
Ring directionality of the optical line
Parameter type is RDIRN_MODE—the optical ring directionality
•E-W
The direction of the signal is from east to west (clockwise)
•W-E
The direction of the signal is from west to east (counterclockwise)
EXPBAND
The expected value of band for this port
Parameter type is OPTICAL_BAND—optical band
•1530.33 to 1532.68
Band 1
•1534.25 to 1536.61
Band 2
•1538.19 to 1540.56
Band 3
•1542.14 to 1544.53
Band 4
•1546.12 to 1548.51
Band 5
•1550.12 to 1552.52
Band 6
•1554.13 to 1556.55
Band 7
•1558.17 to 1560.61
Band 8
•USE-DEFAULT
This band is not yet configured/retrieved from unit
VOAATTN
The value of calibrated attenuation for the VOA expressed in dBm. The range is 0.0 to +30.0. Float
VOAPWR
The value of calibrated output power that the VOA is going to set as a result of its attenuation. Float
CALOPWR
The value of the calibrated optical power expected for the line added to the calculated value which equals the total expected output power. Expressed in dBm. Defaults to 0 dBm. Float
CHPOWER
The value of per channel optical power. Float expressed in dBm
Parameter type is REVERTIVE_TIME—revertive time
•0.5 to 12.0
Revertive time is 0.5 to 12.0 minutes
NAME
Port name. String
SOAK
Integer. Defaults to 8
CMDMDE
Command mode
Parameter type is CMDMDE—forces the system to execute a given command regardless of any standing conditions. Normal mode is the default behavior for all commands but you can specify FRCD to force the system to override a state where the command would normally be denied
•FRCD
Force the system to override a state where the command would normally be denied
•NORM
Execute the command normally. Do not override any conditions that might make the command fail
PST
Primary state
Parameter type is PST—indicates the current overall service condition of an entity
•IS
In service
•OOS
Out of service
SST
Secondary state
Parameter type is SST—provides additional information pertaining to PST and PSTQ
•AINS
Automatic in service
•DSBLD
Disabled
•LPBK
Loopback
•MEA
Mismatch of equipment and attributes
•MT
Maintenance mode
•OOG
Out of group
•SWDL
Software downloading
•UAS
Unassigned
•UEQ
Unequipped
11.33 ED-OSC
Edit Optical Service Channel (OSC)
Usage Guidelines
Cisco ONS 15454
This command edits the OSC (optical service channel) group attributes.
CategoryDWDM
SecurityProvisioning
Related Commands
Input FormatED-OSC:[<TID>]:<AID>:<CTAG>:::[RINGID=<RINGID>],[NODEID=<NODEID>];
Input ExampleED-OSC:PENNGROVE:OSC-1:114:::RINGID=1,NODEID=10;
Input Parameters
Table 11-33 ED-OSC Input Parameters
Parameter and Values DescriptionAID
Access identifier from the "OSC" section
RINGID
The OSC ring ID of the NE, up to six characters. Valid characters are A-Z and 0-9. String. Default value is "# of AID OSC-#". Integer
NODEID
The OSC node ID of the NE. NODEID ranges from 0 to 31. Integer
11.34 ED-OTS
Edit Optical Transport Section (OTS)
Usage Guidelines
Cisco ONS 15454
This command edits the attributes (service parameters) and state of an OTS facility.
CategoryDWDM
SecurityProvisioning
Related Commands
Input FormatED-OTS:[<TID>]:<AID>:<CTAG>:::[RDIRN=<RDIRN>],[VOAATTN=<VOAATTN>],
[VOAPWR=<VOAPWR>],[OFFSET=<OFFSET>],[CALTILT=<CALTILT>],[OSRI=<OSRI>],
[AMPLMODE=<AMPLMODE>],[CHPOWER=<CHPOWER>],[EXPGAIN=<EXPGAIN>],
[NAME=<NAME>],[SOAK=<SOAK>],[CMDMDE=<CMDMDE>]:<PST>,[<SST>];Input ExampleED-OTS:PENNGROVE:LINE-6-1:114:::RDIRN=W-E,VOAATTN=5.0,VOAPWR=10.0,OFFSET=0.0,CALTILT=0.0,OSRI=N,AMPLMODE=GAIN,CHPOWER=10.0,EXPGAIN=-5.0,
NAME="OTS PORT",SOAK=8,CMDMDE=CMDMDE:IS,AINS;Input Parameters
Table 11-34 ED-OTS Input Parameters
Parameter and Values DescriptionAID
Access identifier from the "LINE" section
RDIRN
Ring directionality of the optical line
Parameter type is RDIRN_MODE—the optical ring directionality
•E-W
The direction of the signal is from east to west (clockwise)
•W-E
The direction of the signal is from west to east (counterclockwise)
VOAATTN
The value of calibrated attenuation for the VOA expressed in dBm. The range is 0.0 to +30.0. Float
VOAPWR
The value of calibrated output power that the VOA is going to set as a result of its attenuation. Float
OFFSET
The calibration value of the optical power added to the calculated reference value. Defaults to 0 dBm. Float
CALTILT
The amplifier calibration tilt offset to be added to the calculated reference value. Defaults to 0 dBm. Float. Optional
OSRI
OSRI enabled or disabled. Present only on a port where the safety is supported. Optional
Parameter type is ON_OFF—disable or enable an attribute
•N
Disable an attribute
•Y
Enable an attribute
AMPLMODE
The optical amplification control mode
Parameter type is AMPL_MODE—defines amplifier control mode
•GAIN
The amplifier always maintains a fixed gain
•POWER
The amplifier maintains the output power to a fixed value
CHPOWER
The per channel optical power. Float
EXPGAIN
The gain expected value to be reached from an amplifier when the node is part of a DWDM access network. Float
NAME
The name of the port. String
SOAK
Integer. Defaults to 8
CMDMDE
Command mode
Parameter type is CMDMDE—forces the system to execute a given command regardless of any standing conditions. Normal mode is the default behavior for all commands but you can specify FRCD to force the system to override a state where the command would normally be denied
•FRCD
Force the system to override a state where the command would normally be denied
•NORM
Execute the command normally. Do not override any conditions that might make the command fail
PST
Primary state
Parameter type is PST—indicates the current overall service condition of an entity
•IS
In service
•OOS
Out of service
SST
Secondary state
Parameter type is SST—provides additional information pertaining to PST and PSTQ
•AINS
Automatic in service
•DSBLD
Disabled
•LPBK
Loopback
•MEA
Mismatch of equipment and attributes
•MT
Maintenance mode
•OOG
Out of group
•SWDL
Software downloading
•UAS
Unassigned
•UEQ
Unequipped
11.35 ED-PID
Edit Password
Usage Guidelines
Cisco ONS 15454, ONS 15327, ONS 15600, ONS 15310-CL
This command allows a user to change his or her own password.
Note•Passwords are masked for the following security commands: ACT-USER, ED-PID, ENT-USER-SECU and ED-USER-SECU. Access to a TL1 session by any means will have the password masked. The CTC Request History and Message Log will also show the masked commands. When a password-masked command is reissued by double-clicking the command from CTC Request History, the password will still be masked in the CTC Request History and Message Log. The actual password that was previously issued will be sent to the NE. To use a former command as a template only, single-click the command in CTC Request History. The command will be placed in the Command Request text box, where you can edit the appropriate fields prior to reissuing it.
•The password will not appear in the TL1 log on the NE.
•For the ED-PID command:
ED-PID:[TID]:<UID>:[CTAG]::<OLDPID>,<NEWPID>;
The syntax of OLDPID is not checked. The NEWPID is required to follow Telcordia standards (for example, 10 characters maximum including 1 letter, 1 number, and any one of the following characters: #, %, or +). The OLDPID must match what is in the database.
You must use the ED-USER-SECU command to change the default password for the CISCO15 superuser.
•The ED-PID command cannot be used to change the empty password to a valid password.
CategorySecurity
SecurityRetrieve
Related Commands
Input FormatED-PID:[<TID>]:<UID>:<CTAG>::<OLDPID>,<NEWPID>;
Input ExampleED-PID:CISCO:UID:123::OLDPWD,NEWPWD;
Input Parameters
11.36 ED-POS
Edit Packet Over SONET
Usage Guidelines
Cisco ONS 15454, ONS 15310-CL, ONS 15600
This command edits the back end port information for the Ethernet card when the back end port is working in POS mode. The default values for all optional parameters are NE default values. These values might not be the current value for a parameter. In order to obtain the current value, issue the RTRV-XX command to retrieve them. ED-POS cannot set ENCAP and PST/SST.
Note This command is supported for the ONS 15454 CE-100T-8 card, the ONS 15310-CL ML-100T-8 and CE-100T-8 cards and the ONS 15600 ASAP card.
CategoryPorts
SecurityProvisioning
Related Commands
Input FormatED-POS:[<TID>]:<AID>:<CTAG>:::[ENCAP=<ENCAP>],[NAME=<NAME>],
[CMDMDE=<CMDMDE>],[SOAK=<SOAK>]:[<PST>[,<SST>]];Input ExampleED-POS:CISCO:VFAC-2-0:123:::ENCAP=HDLC,NAME=NAME,CMDMDE=CMDMDE,
SOAK=32:IS,AINS;Input Parameters
Table 11-36 ED-POS Input Parameters
Parameter and Values DescriptionAID
Access identifier from the "FACILITY" section
ENCAP
Encapsulation
Parameter type is ENCAP—frame encapsulation type
•GFP_F
GFP frame mode
•GFP_T
GFP transparent mode
•HDLC
HDLC frame mode
•HDLC_LEX
HDLC LAN extension frame mode
•HDLC_X86
HDLC X.86 frame mode
NAME
Port name. String
CMDMDE
Command Mode. The FRCD mode of operation is applicable to delete a VCAT member cross-connect from IS-NR or OOS-AU,AINS service state
Parameter type is CMDMDE—forces the system to execute a given command regardless of any standing conditions. Normal mode is the default behavior for all commands but you can specify FRCD to force the system to override a state where the command would normally be denied
•FRCD
Force the system to override a state where the command would normally be denied
•NORM
Execute the command normally. Do not override any conditions that might make the command fail
SOAK
OOS-AINS to IS transition soak time as measured in 15 minute intervals, so a value of 4 translates to a soak time of 1 hour. The allowable range is 0 to 192 intervals (maximum of 48 hours). Integer
PST
Primary state
Parameter type is PST—indicates the current overall service condition of an entity
•IS
In service
•OOS
Out of service
SST
Secondary state
Parameter type is SST—provides additional information pertaining to PST and PSTQ
•AINS
Automatic in service
•DSBLD
Disabled
•LPBK
Loopback
•MEA
Mismatch of equipment and attributes
•MT
Maintenance mode
•OOG
Out of group
•SWDL
Software downloading
•UAS
Unassigned
•UEQ
Unequipped
11.37 ED-PROTOCOL
Edit Protocol
Usage Guidelines
Cisco ONS 15454, ONS 15327, ONS 15600, ONS 15310-CL
This command is used to enable/disable a protocol/service that is supported in the NE. Valid protocols include shell/file system access (SHELL), EMS, TL1 and SNMP.
Note If the AID is TL1 the command will be denied because TL1 users are not allowed to change the setting for TL1 protocol.
Note If the AID is SNMP the SECURE PROTOCOLSTAT is not supported. SNMP can only be enabled or disabled. To enable SNMP, set PROTOCOLSTAT to UNSECURE.
CategorySecurity
SecuritySuperuser
Related Commands
Input FormatED-PROTOCOL:[<TID>]:<PROTOCOLAID>:<CTAG>::<PROTOCOLSTAT>;
Input ExampleED-PROTOCOL:CISCONODE:EMS:123::SECURE;
Input Parameters
11.38 ED-ROLL-<MOD_PATH>
Edit Roll (STS1, STS12C, STS192C, STS24C, STS3C, STS48C, STS6C, STS9C, VT1, VT2)
Usage Guidelines
Cisco ONS 15454, ONS 15327, ONS 15600
This command forces a rolling operation. Force attempts to force a valid signal to complete the rolling operation.
See Table 27-1 for supported modifiers by platform.
Note STS18C and STS36C are not supported for this command in this release.
CategoryBridge and Roll
SecurityProvisioning
Related Commands
Input FormatED-ROLL-<MOD_PATH>:[<TID>]:<FROM>,<TO>:<CTAG>[:::CMDMDE=<CMDMDE>];
Input ExampleED-ROLL-STS1:CISCO:STS-1-1-1,STS-2-1-1:1:::CMDMDE=FRCD;
Input Parameters
Table 11-38 ED-ROLL-<MOD_PATH> Input Parameters
Parameter and Values DescriptionFROM
Source access identifier from the "CrossConnectId1" section. It is one of the termination points (legs) of the existing cross-connection. If the existing cross-connection is one-way, then this termination point (leg) should be the FROM-AID termination point. Otherwise, FROM is non-significant. FROM and TO should be entered as they are entered in the ENT-CRS command. You can issue RTRV-CRS command, and use the response for FROM and TO parameters
TO
Destination access identifier from the "CrossConnectId1" section. It is one of the termination points (legs) of the existing cross-connection. If the existing cross-connection is one-way, then this termination point (leg) should be the TO-AID termination point. Otherwise, the TO is non-significant. FROM and TO should be entered as they are entered in the ENT-CRS command. You can issue RTRV-CRS command, and use the response for FROM and TO parameters
CMDMDE
Command execution mode. Defaults to NORM.
Note CMDMDE can only go from NORM to FRCD (cannot go from FRCD to NORM). CMDMDE cannot be set to NORM using this command
Parameter type is CMDMDE—forces the system to execute a given command regardless of any standing conditions. Normal mode is the default behavior for all commands but you can specify FRCD to force the system to override a state where the command would normally be denied
•FRCD
Force the system to override a state where the command would normally be denied
•NORM
Execute the command normally. Do not override any conditions that might make the command fail
11.39 ED-SLV-WDMANS
Edit Span Loss Verification Wavelength Division Multiplexing Automatic Node Set Up
Usage Guidelines
Cisco ONS 15454
This command edits the expected span loss verification.
CategoryDWDM
SecurityMaintenance
Related Commands
Input FormatED-SLV-WDMANS:[<TID>]:<AID>:<CTAG>:::[HIGHSLVEXP=<HIGHSLVEXP>],
[LOWSLVEXP=<LOWSLVEXP>];Input ExampleED-SLV-WDMANS:VA454-22:WDMANS-E:116:::HIGHSLVEXP=10.0,LOWSLVEXP=5.0;
Input Parameters
Table 11-39 ED-SLV-WDMANS Input Parameters
Parameter and Values DescriptionAID
Access identifier from the "WDMANS" section
HIGHSLVEXP
The high range value of the expected span loss verification. Float
LOWSLVEXP
The low range value of the expected span loss verification. Float
11.40 ED-SYNCN
Edit Synchronization
Usage Guidelines
Cisco ONS 15454, ONS 15327, ONS 15600, ONS 15310-CL
This command edits the synchronization reference list used to determine the sources for the NE's reference clock and the BITS output clock. For each clock, up to three synchronization sources might be specified (for example, PRIMARY, SECOND, THIRD).To view or edit the system timing mode, use the RTRV-NE-SYNCN or ED-NE-SYNCN commands.
Note To retrieve/set the timing mode, SSM message Set or Quality of RES information, use the RTRV-NE-SYNCN and ED-NE-SYNCN commands.
CategorySynchronization
SecurityProvisioning
Related Commands
ED-BITS
ED-NE-SYNCN
OPR-SYNCNSW
REPT ALM BITS
REPT ALM SYNCN
REPT EVT BITS
REPT EVT SYNCN
RLS-SYNCNSW
RTRV-ALM-BITS
RTRV-ALM-SYNCN
RTRV-BITS
RTRV-COND-BITS
RTRV-COND-SYNCN
RTRV-NE-SYNCN
RTRV-SYNCN
Input FormatED-SYNCN:[<TID>]:<AID>:<CTAG>:::[PRI=<PRI>],[SEC=<SEC>],[THIRD=<THIRD>][:];
Input ExampleED-SYNCN:BOYES:SYNC-NE:112:::PRI=INTERNAL,SEC=INTERNAL,THIRD=INTERNAL;
Input Parameters
Table 11-40 ED-SYNCN Input Parameters
Parameter and Values DescriptionAID
Access identifier from the "SYNC_REF" section
PRI
Primary reference of the synchronization from the "SYN_SRC" section
SEC
Secondary reference of the synchronization from the "SYN_SRC" section
THIRD
Third reference of the synchronization from the "SYN_SRC" section
11.41 ED-T1
Edit Digital Signal Facility
Usage Guidelines
Cisco ONS 15454, ONS 15327, ONS 15310-CL
This command edits the attributes related to a DS1/T1 port.
Note•The T1 facilities on the ONS 15327 and ONS 15310-CL are on the XTC/15310-CL-CTX card.
•This command is not allowed if the card is a protecting card.
•If sending this command to edit TACC and any other attribute(s), and the port having the cross-connection, the (Parameters Not compatible) error message will be returned.
•Editing TACC using an ED-xxx command is only allowed when there is no circuit/cross-connection on this port and the port/VT does not have a test access point (TAP or TACC number). Otherwise, an error message (for example, VT in Use) will be returned.
•TACC creation will also be denied on the protect ports/cards.
•AUTO-PROV is not supported.
•The AISONLPBK and RETIME options are applicable only to the ONS 15310-CL and the DS2-E1-56 card on the ONS 15454.
•The default values for all optional parameters are NE default values. These values might not be the current value for a parameter. Use the RTRV-XX commands to retrieve the current values.
•The parameters: SYNCMAP, ADMSSM, VTMAP and INHFELPBK are only supported on the DS1-E1-56 card (ONS 15454).
CategoryPorts
SecurityProvisioning
Related Commands
Input FormatED-T1:[<TID>]:<AID>:<CTAG>:::[LINECDE=<LINECDE>],[FMT=<FMT>],[LBO=<LBO>],
[TACC=<TACC>],[TAPTYPE=<TAPTYPE>],[SOAK=<SOAK>],[SFBER=<SFBER>],
[SDBER=<SDBER>],[SYNCMSG=<SYNCMSG>],[SENDDUS=<SENDDUS>],
[RETIME=<RETIME>],[NAME=<NAME>],[MODE=<MODE>],[SYNCMAP=<SYNCMAP>],
[ADMSSM=<ADMSSM>],[VTMAP=<VTMAP>],[INHFELPBK=<INHFELPBK>],
[AISONLPBK=<AISONLPBK>],[CMDMDE=<CMDMDE>],
[AISVONAIS=<AISVONAIS>]:[<PST>[,<SST>]];Input ExampleED-T1:CISCO:FAC-2-1:1223:::LINECDE=AMI,FMT=ESF,LBO=0-131,TACC=8,
TAPTYPE=SINGLE,SOAK=10,SFBER=1E-4,SDBER=1E-6,SYNCMSG=Y,SENDDUS=Y,
RETIME=Y,NAME="T1PORT",MODE=FDL,SYNCMAP=ASYNC,ADMSSM=STU,
VTMAP=GR253,INHFELPBK=N,AISONLPBK=AIS_ON_LPBK_ALL,CMDMDE=CMDMDE,
AISVONAIS=Y:IS,AINS;Input Parameters
Table 11-41 ED-T1 Input Parameters
Parameter and Values DescriptionAID
Access identifier from the "FACILITY" section
LINECDE
Line code
Parameter type is LINE_CODE—line code
•AMI
Line code value is AMI
•B8ZS
Line code value is B8ZS (bipolar with three-zero substitution)
FMT
Digital signal frame format
Parameter type is FRAME_FORMAT—frame format for a T1 port
•D4
Frame format is D4
•ESF
Frame format is ESF
•UNFRAMED
Frame format is unframed
LBO
Line buildout settings. Integer
Parameter type is LINE_BUILDOUT—Line buildout
•0-131
Line buildout range is 0-131
•132-262
Line buildout range is 132-262
•263-393
Line buildout range is 263-393
•394-524
Line buildout range is 394-524
•525-655
Line buildout range is 525-655
TACC
TAP number within a range of 0 to 999. Indicates whether the digroup being provisioned is to be used as a test access digroup. When TACC is 0 (zero), the TAP is deleted. Default is N. Integer
TAPTYPE
TAP type. Defaults to DUAL
Parameter type is TAPTYPE—test access point type
•DUAL
Dual FAD
•SINGLE
Single FAD
SOAK
OOS-AINS to IS transition soak time as measured in 15-minute intervals. A value of 4 equals a soak time of 1 hour. The allowable range is 0 to 192 intervals (maximum of 48 hours). Integer
SFBER
The port signal failure threshold
Parameter type is SF_BER—the threshold for declaring signal failure on a facility or path
•1E-3
SFBER is 1E-3
•1E-4
SFBER is 1E-4
•1E-5
SFBER is 1E-5
SDBER
Port signal degrade threshold
Parameter type is SD_BER—the threshold for declaring signal degrade on a facility or path
•1E-5
SDBER is 1E-5
•1E-6
SDBER is 1E-6
•1E-7
SDBER is 1E-7
•1E-8
SDBER is 1E-8
•1E-9
SDBER is 1E-9
SYNCMSG
Synchronization status messaging is enabled or disabled on the T1 facility.
Note For ONS 15310-CL, SYNCMSG defaults to N. SYNCMSG is not supported on the ONS 15454 or ONS 15327
Parameter type is YES_NO—whether the user's password is about to expire, the user is logged into the NE, or the user is locked out of the NE
•NO
No
•YES
Yes
SENDDUS
The facility will send the DUS (Don't use for Synchronization) value as the sync status message for that facility
Note For ONS 15310-CL, SENDDUS is optional and defaults to N. SENDDUS is not supported on the ONS 15454 or ONS 15327
Parameter type is YES_NO—whether the user's password is about to expire, the user is logged into the NE, or the user is locked out of the NE
•NO
No
•YES
Yes
RETIME
Indicates if retiming is needed.
Note For ONS 15310-CL, RETIME is optional and defaults to N. RETIME is not supported on the ONS 15454 or ONS 15327
Parameter type is YES_NO—whether the user's password is about to expire, the user is logged into the NE, or the user is locked out of the NE
•NO
No
•YES
Yes
NAME
Name. String
MODE
Mode. Default value is FDL
Parameter type is DS1MODE—the DS1 path mode of the DS3XM-12 card
•ATT
Indicates the DS1 path of the DS3XM-12 is in AT&T 54016 mode
•FDL
Indicates the DS1 path of the DS3XM-12 is in FDL T1-403 mode
SYNCMAP
The synchronous mapping for the DS1 facility. Defaults to ASYNC. Only supported on ONS 15454.
Parameter type is SYNCMAP—synchronous mapping type
•ASYNC
Asynchronous
•BYTE
Mapping in byte
•JBYTE
Mapping in jbyte
ADMSSM
The administrative synchronization status message. Only supported on the ONS 15454. Defaults to STU
Parameter type is SYNC_CLOCK_REF_QUALITY_LEVEL—clock source quality level
•DUS
Do Not Use For Synchronization
•PRS
Primary Reference Source, Stratum 1 Traceable
•RES
Reserved For Network Synchronization Use
•SMC
SONET Minimum Clock Traceable
•ST2
Stratum 2 Traceable
•ST3
Stratum 3 Traceable
•ST3E
Stratum 3E Traceable
•ST4
Stratum 4 Traceable
•STU
Synchronized, Traceability Unknown
•TNC
Transit Node Clock (2nd Generation Only)
VTMAP
The port to VT mapping type for that particular STS. Only supported on ONS 15454. Defaults to GR253
Parameter type is VTMAP—VT mapping
•GR253
Mapping based on GR253
•INDUSTRY
Mapping based on industry standard
INHFELPBK
Indicates whether far end loopbacks are inhibited on the facility. Only supported on ONS 15454. Defaults to N
Parameter type is ON_OFF—disable/enable an attribute
•N
Disable an attribute
•Y
Enable an attribute
AISONLPBK
Defaults to AIS_ON_LPBK_ALL
Parameter type is AIS_ON_LPBK—Indicates if AIS is sent on a loopback
•AIS_ONLPBK_FACILITY
AIS is sent on facility loopbacks
•AIS_ON_LPBK_ALL
AIS is sent on all loopbacks
•AIS_ON_LPBK_OFF
AIS is not sent on loopbacks
•AIS_ON_LPBK_TERMINAL
AIS is sent on terminal loopbacks
CMDMDE
Command mode
Parameter type is CMDMDE—forces the system to execute a given command regardless of any standing conditions. Normal mode is the default behavior for all commands but you can specify FRCD to force the system to override a state where the command would normally be denied
•FRCD
Force the system to override a state where the command would normally be denied
•NORM
Execute the command normally. Do not override any conditions that might make the command fail
AISVONAIS
Defaults to N
Parameter type is ON_OFF—disable/enable an attribute
•N
Disable an attribute
•Y
Enable an attribute
PST
Primary state
Parameter type is PST—indicates the current overall service condition of an entity
•IS
In service
•OOS
Out of service
SST
Secondary state
Parameter type is SST—provides additional information pertaining to PST and PSTQ
•AINS
Automatic in service
•DSBLD
Disabled
•LPBK
Loopback
•MEA
Mismatch of equipment and attributes
•MT
Maintenance mode
•OOG
Out of group
•SWDL
Software downloading
•UAS
Unassigned
•UEQ
Unequipped
11.42 ED-T3
Edit Digital Signal Facility
Usage Guidelines
Cisco ONS 15454, ONS 15327, ONS 15310-CL
This command edits the attributes related to a DS3/T3 port and DS3I card.
Note•The T3 facilities on the ONS 15327 and ONS 15310-CL are on the XTC/15310-CL-CTX card.
•This command is not allowed if the card is a protecting card.
•Both FMT and Line code are not supported for T3/DS3 facility. They are supported on both the DS3XM and DS3E card. The unframed value of the framing format is only supported on the DS3E facility.
•If sending this command to edit TACC and any other attribute(s), and the port having the cross-connection or the port/VT has a test access point (TAP or TACC number), the (Parameters Not compatible) error message will be returned.
•Editing TACC using an ED-xxx command is only allowed when there is no circuit/cross-connection on the port and the port/VT does not have a test access point (TAP or TACC number). Otherwise, an error message (VT in Use) will be returned.
•TACC creation will also be denied on the protect ports/cards.
•Automatic application of loopbacks originating from the far end can be initiated on the T3 ports of a DS3E, DS3NE, or DS3XM card.
•CTC can set the FMT attribute of a DS3(N)E line to AUTOPROVISION to set the framing based on the framing that is coming in. The result is the FMT field being blanked out for a few seconds or blanked out indefinitely for a preprovisioned DS3(N)E card in CTC. The AUTOPROVISION is not considered a valid DS3 framing type. It is only used to trigger an autosense and subsequent auto provisioning of a valid DS3 framing type (unframed, M13, C-BIT). TL1 does not have the AUTOPROVISION mode. TL1 maps/returns the AUTOPROVISION mode to the unframed framing type.
•For the DS3XM-12 card, the DS3/T3 configurable attributes (PM, TH, alarm, etc.) only apply on the ported ports (1-12) and the DS3-mapped (even) portless ports in xxx-xxx-T3 commands. If you attempt to provision or retrieve DS3/T3 attributes on the VT-mapped (odd) portless port in xxx-xxx-T3 commands, an error message will be returned.
•For the DS3XM-12 card, if the admin state is already set for a portless port the state setting operation over its associated ported port is an invalid operation.
•The test set physical connection set up through ED-T3/DS1/STS1/VT1 of the DS3XM-12 card is only allowed on the physical front ports (PORTED ports, ports 1-12), which are the monitoring ports.
–The monitoring test access ports follow the common rules for the other cards. For example, ED-T3 on port 2 (FAC-6-2) with a TACC number (8), the next port, port 3 (FAC-6-3) is used as the monitoring point also. The RTRV-T3 on both port-2 and port-3 return the same TACC number (8) being used to monitor the cross-connection end (A-B). The last port (port 12) is not allowed to set-up a physical connection with the test set because there is no next available port to be the monitoring port.
–The TACC disconnection (DISC-TACC) command and the test access mode change (CHG-TACC) command follow the same requirement as in note 11a. above, but applied on the ported ports of the DS3XM-12 card.
–The test access connection set-up (CONN-TACC) command has monitored points which can be portless ports. This command is applied on both ported and portless ports of the DS3XM-12 card.
•If the entity has a TACC connection, the entity is not allowed to have ported or portless STS/VT cross-connection (or circuit) provisioning on the DS3XM-12 card.
•ED-T3 cannot be used to create TAPs on the DS3I card on the SONET platform because the DS3I card only supports STS3C TAPs.
•You cannot use this command to change the default provisioning on Slots 3 and 15 for the DS3-EC1-48 card.
•The AISONLPBK is only applicable to the ONS 15310-CL.
•The default values for all optional parameters are NE default values. These values might not be the current value for a parameter. Use the RTRV-XX command to retrieve current default values.
CategoryPorts
SecurityProvisioning
Related Commands
Input FormatED-T3:[<TID>]:<AID>:<CTAG>:::[FMT=<FMT>],[LINECDE=<LINECDE>],[LBO=<LBO>],
[INHFELPBK=<INHFELPBK>],[TACC=<TACC>],[TAPTYPE=<TAPTYPE>],[SOAK=<SOAK>],
[SFBER=<SFBER>],[SDBER=<SDBER>],[NAME=<NAME>],[AISONLPBK=<AISONLPBK>],
[CMDMDE=<CMDMDE>]:[<PST>[,<SST>]];Input ExampleED-T3:CISCO:FAC-1-2:123:::FMT=C-BIT,LINECDE=B3ZS,LBO=0-225,INHFELPBK=N,
TACC=8,TAPTYPE=SINGLE,SOAK=10,SFBER=1E-4,SDBER=1E-6,NAME="T3 PORT",
AISONLPBK=AIS_ON_LPBK_ALL,CMDMDE=CMDMDE:IS,AINS;Input Parameters
Table 11-42 ED-T3 Input Parameters
Parameter and Values DescriptionAID
Access identifier from the "FACILITY" section
FMT
Digital signal frame format. The unframed value of the framing format is only supported for the DS3E card
Parameter type is DS_LINE_TYPE—DS123 line type
•C-BIT
C-BIT line type applies to the DS3XM and DS3E cards
•M13
M13 line type applies to the DS3XM and DS3E cards
•UNFRAMED
Line type is unframed. The old DS3 (L3M) and DS3CR cards can only run in unframed mode
LINECDE
Line code
Parameter type is DS_LINE_CODE—DS123 line code
•B3ZS
Bipolar with three-zero substitution
LBO
Line build out settings. Integer
Parameter type is E_LBO—electrical signal line buildout
•0-225
Electrical signal line buildout range is 1-225
•226-450
Electrical signal line buildout range is 226-450
INHFELPBK
Far end loopback inhibition attribute of the port. If it is Y, the automatic far end loopbacks are inhibited. It is either on or off. The system default is N. Optional
Parameter type is ON_OFF—disable or enable an attribute
•N
Disable an attribute
•Y
Enable an attribute
TACC
TAP number within a range of 0 to 999. Indicates whether the digroup being provisioned is to be used as a test access digroup. When TACC is 0 (zero), the TAP is deleted. Default is N. Integer
TAPTYPE
TAP type. Defaults to DUAL
Parameter type is TAPTYPE—test access point type
•DUAL
Dual FAD
•SINGLE
Single FAD
SOAK
OOS-AINS to IS transition soak time as measured in 15-minute intervals. A value of 4 equals a soak time of 1 hour. The allowable range is 0 to 192 intervals (maximum of 48 hours). Integer
SFBER
The port signal failure threshold
Parameter type is SF_BER—the threshold for declaring signal failure on a facility or path
•1E-3
SFBER is 1E-3
•1E-4
SFBER is 1E-4
•1E-5
SFBER is 1E-5
SDBER
Port signal degrade threshold
Parameter type is SD_BER—the threshold for declaring signal degrade on a facility or path
•1E-5
SDBER is 1E-5
•1E-6
SDBER is 1E-6
•1E-7
SDBER is 1E-7
•1E-8
SDBER is 1E-8
•1E-9
SDBER is 1E-9
NAME
Name. String
AISONLPBK
Defaults to AIS_ON_LPBK_ALL
Parameter type is AIS_ON_LPBK—Indicates if AIS is sent on a loopback
•AIS_ONLPBK_FACILITY
AIS is sent on facility loopbacks
•AIS_ON_LPBK_ALL
AIS is sent on all loopbacks
•AIS_ON_LPBK_OFF
AIS is not sent on loopbacks
•AIS_ON_LPBK_TERMINAL
AIS is sent on terminal loopbacks
CMDMDE
Command mode
Parameter type is CMDMDE—forces the system to execute a given command regardless of any standing conditions. Normal mode is the default behavior for all commands but you can specify FRCD to force the system to override a state where the command would normally be denied
•FRCD
Force the system to override a state where the command would normally be denied
•NORM
Execute the command normally. Do not override any conditions that might make the command fail
PST
Primary state
Parameter type is PST—indicates the current overall service condition of an entity
•IS
In service
•OOS
Out of service
SST
Secondary state
Parameter type is SST—provides additional information pertaining to PST and PSTQ
•AINS
Automatic in service
•DSBLD
Disabled
•LPBK
Loopback
•MEA
Mismatch of equipment and attributes
•MT
Maintenance mode
•OOG
Out of group
•SWDL
Software downloading
•UAS
Unassigned
•UEQ
Unequipped
11.43 ED-TRAPTABLE
Edit Trap Table
Usage Guidelines
Cisco ONS 15454, ONS 15327, ONS 15600, ONS 15310-CL
This command edits a trap destination entry identified by a specific trap destination address.
CategorySystem
SecurityProvisioning
Related Commands
Input FormatED-TRAPTABLE:[<TID>]:<AID>:<CTAG>:::COMMUNITY=<COMMUNITY>,
[TRAPPORT=<TRAPPORT>],[TRAPVER=<TRAPVER>];Input ExampleED-TRAPTABLE::1.2.3.4:1:::COMMUNITY="PUBLIC",TRAPPORT=162,TRAPVER=SNMPV1;
Input Parameters
Table 11-43 ED-TRAPTABLE Input Parameters
Parameter and Values DescriptionAID
Access identifier from the "IPADDR" section. IP address identifying the trap destination
COMMUNITY
Community name associated to the trap destination. Maximum of 32 characters. String
TRAPPORT
UDP port number associated with the trap destination. Default to 162. Integer
TRAPVER
SNMP version number. Defaults to SNMPv1
Parameter type is SNMP_VERSION—SNMP version
•SNMPV1
SNMP version 1 (default)
•SNMPV2
SNMP version 2
11.44 ED-TRC-OCH
Edit Trace Optical Channel Facility
Usage Guidelines
Cisco ONS 15454
The command edits trace-related optical channel facilities.
Refer to the Cisco ONS SONET TL1 Reference Guide for specific card provisioning rules.
CategoryDWDM
SecurityProvisioning
Related Commands
Input FormatED-TRC-OCH:[<TID>]:<SRC>:<CTAG>:::[EXPTRC=<EXPTRC>],[TRC=<TRC>],
[TRCMODE=<TRCMODE>],[TRCLEVEL=<TRCLEVEL>],[TRCFORMAT=<TRCFORMAT>][:];Input ExampleED-TRC-OCH:CISCO:CHAN-6-2:10:::EXPTRC="AAA",TRC="AAA",TRCMODE=MAN,
TRCLEVEL=TTI-PM,TRCFORMAT=64-BYTE;Input Parameters
Table 11-44 ED-TRC-OCH Input Parameters
Parameter and Values DescriptionSRC
Source access identifier from the "CHANNEL" section
EXPTRC
Expected path trace content. Indicates the expected path trace message (J1) contents. EXPTRC is any 64-character ASCII string, including the terminating CR (carriage return) and LF (line feed). A null value is equivalent to ALL. String
TRC
The path trace message to be transmitted. The trace byte continuously transmits a 64 byte, fixed length ASCII string, one byte at a time. A null value defaults to the NE transmitting 62 null characters (Hex 00) and CR and LF. A null value is equivalent to ALL
TRCMODE
Trace mode. Defaults to the OFF mode
Parameter type is TRCMODE—trace mode
•AUTO
Use the previously received path trace string as the expected string. Not applicable to MXP/TXP cards
•AUTO-NO-AIS
Use the previously received path trace string as the expected string and do not turn on AIS and RDI if TIMP is detected
•MAN
Use the provisioned expected string as the expected string
•MAN-NO-AIS
Use the provisioned expected string as the expected string and do not turn on AIS and RDI if TIMP is detected
•OFF
Turn off path trace capability. Nothing will be reported
TRCLEVEL
The trace level to be managed. String
TRCFORMAT
Trace message size
Parameter type is TRCFORMAT—trace format
•1-BYTE
1 byte trace message
•16-BYTE
16 byte trace message
•64-BYTE
64 byte trace message
•Y
Enable an attribute
11.45 ED-USER-SECU
Edit User Security
Usage Guidelines
Cisco ONS 15454, ONS 15327, ONS 15600, ONS 15310-CL
This command edits a user's privileges, password, or ID. Only a Superuser might perform this operation. Privilege levels are described in the ENT-USER-SECU command.
Note•Passwords are masked for the following security commands: ACT-USER, ED-PID, ENT-USER-SECU and ED-USER-SECU. Access to a TL1 session by any means will have the password masked. The CTC Request History and Message Log will also show the masked commands. When a password-masked command is reissued by double-clicking the command from CTC Request History, the password will still be masked in the CTC Request History and Message Log. The actual password that was previously issued will be sent to the NE. To use a former command as a template only, single-click the command in CTC Request History. The command will be placed in the Command Request text box, where you can edit the appropriate fields prior to reissuing it.
•Although the CTC allows both <UID> and <PID> of up to 20 characters, the CTC-entered users (<UID>, <PID>) are not valid TL1 users (for example, if issuing an ACT-USER command and using the CTC-entered <UID> that is greater than 10 characters long, TL1 will respond with DENY.
•For the ED-USER-SECU command;
ED-USER-SECU:[TID]:<UID>:[CTAG]::[<NEWUID>],[<NEWPID>],,[<UAP>]:;
–If the <NEWPID> is specified, the syntax is checked.
–The syntax of <UID> is not checked.
–Old users can change their password without changing their userid, but the new password must meet the new requirements.
–The <NEWPID> is required when changing the <USERID>.
•In this release, when <NEWUID> is specified, <NEWPID> (and the <UAP>) become mandatory, but it is possible to change a USERID without changing the password by providing the same password. You cannot keep your old password if the old password does not meet the new syntax requirements. For example:
–<USERID> = CISCO2345
<PASSWORD>=CISCO#234 /*PASSWORD ALREADY MEETS REQUIREMENTS*/ED-USER-SECU::CISCO2345:1::CISCO3456,CISCO#234,,PROV;
TCCP 1970-01-02 13:15:35 M 1 COMPLD ;
–<NEWUSERID> = CISCO60
<USERID> = CISCO40 <PASSWORD>=CISCO40 /*PASSWORD DOES NOT MEET REQUIREMENTS*/ED-USER-SECU::CISCO40:1::CISCO60,CISCO40,,PROV;
BRONCOS4 1970-01-02 13:14:24 M 1 DENY IIFM /* INVALID PASSWORD */ ;
•The ED-USER-SECU command should be used to change the default password for the CISCO15 default superuser.
•The ED-PID command cannot be used to change the empty password to a valid password.
CategorySecurity
SecuritySuperuser
Related Commands
Input FormatED-USER-SECU:[<TID>]:<UID>:<CTAG>::[<NEWUID>],[<NEWPID>],,[<UAP>][:];
Input ExampleED-USER-SECU:PETALUMA:CISCO15:123::NEWUID,NEWPID,,MAINT;
Input Parameters
11.46 ED-VCG
Edit Virtual Concatenated Group
Usage Guidelines
Cisco ONS 15454, ONS 15310-CL
This command edits the attributes of a VCG.
CategoryVCAT
SecurityProvisioning
Related Commands
Input FormatED-VCG:[<TID>]:<SRC>:<CTAG>:::[TXCOUNT=<TXCOUNT>],[NAME=<NAME>];
Input ExampleED-VCG:NODE1:FAC-1-1:1234:::TXCOUNT=7,NAME="VCG2";
Input Parameters
Table 11-46 ED-VCG Input Parameters
Parameter and Values DescriptionSRC
Source access identifier from the "FACILITY" section
TXCOUNT
Number of members in the Tx direction. For ML1000-2 and ML100T-12 cards the only valid value is 2. For the FC_MR-4 card the only valid value is 8. Integer
NAME
Name of the VCAT group. Maximum length is 64 characters. String.
11.47 ED-WDMANS
Edit Wavelength Division Multiplexing Automatic Node Set Up
Usage Guidelines
Cisco ONS 15454
This command edits the optical node set-up application (AONS) attributes.
CategoryDWDM
SecurityMaintenance
Related Commands
Input FormatED-WDMANS:[<TID>]:<AID>:<CTAG>:::[POWER-IN=<POWERIN>],
[POWER-OUT=<POWEROUT>],[POWER-EXP=<POWEREXP>],[NTWTYPE=<NTWTYPE>];Input ExampleED-WDMANS:PENNGROVE:WDMANS-W:114:::POWERIN=10.0,POWEROUT=10.0,|
POWEREXP=10.0,NTWTYPE=METRO-CORE;Input Parameters
Table 11-47 ED-WDMANS Input Parameters
Parameter and Values DescriptionAID
Access identifier from the "WDMANS" section
POWERIN
Input power for OADM section or Mux/Demux for terminal nodes. Float
POWEROUT
Output power for OADM section or Mux/Demux for terminal nodes. Float
POWEREXP
Express power for OADM section. Float
NTWTYPE
Network type where a DWDM node is installed
Parameter type is DWDM_RING_TYPE—network type where NE is installed
•METRO-ACCESS
The network where a DWDM node is installed is a metro access network
•METRO-CORE
The network where a DWDM node is installed is a metro core network
•NONE
A node that does not have a standard DWDM configuration
11.48 ED-WLEN
Edit Wavelength
Usage Guidelines
Cisco ONS 15454
This command edits WLEN (wavelength) provisioning.
Note•The fields after CTAG (trailing colons) are optional.
•This command does not support multiple editing of WLEN provisioning.
•The maximum length of the SIZE parameter is 48 characters.
•CKTID is a string of ASCII characters. The maximum length of a CKTID can be 48. If CKTID is EMPTY or NULL this field will not appear.
CategoryDWDM
SecurityProvisioning
Related Commands
Input FormatED-WLEN:[<TID>]:<AID>:<CTAG>:::[SIZE=<SIZE>],[CKTID=<CKTID>],
[CMDMDE=<CMDMDE>]:[<PST>[,<SST>]];Input ExampleED-WLEN:PENNGROVE:WLEN-W-ADD-1530.33:1:::SIZE=NOT-SPEC,CKTID=CKTID,
CMDMDE=CMDMDE:IS,AINS;Input Parameters
Table 11-48 ED-WLEN Input Parameters
Parameter and Values DescriptionAID
Access identifier from the "WLEN" section
SIZE
Size of the switching network. Defaults to NOT-SPEC
Parameter type is CIRCUIT_SIZE—the DWDM circuit size used on a wavelength
•10G-FEC
The circuit size is 10 Gbps with FEC
•10G-NO-FEC
The circuit size is10 Gbps without FEC
•2G5-FEC
The circuit size is 2.5 Gbps with FEC
•2G5-NO-FEC
The circuit size is 2.5 Gbps without FEC
•MULTI-RATE
The circuit size is supports multirate
•NOT-SPEC
The circuit size is not equipment specific
CKTID
Circuit ID. String. Defaults to " " (empty string)
CMDMDE
Command execution mode, forced or normal. FRCD is only applicable if the PST=OOS and SST=DSBLD
Parameter type is CMDMDE—forces the system to execute a given command regardless of any standing conditions. Normal mode is the default behavior for all commands but you can specify FRCD to force the system to override a state where the command would normally be denied
•FRCD
Force the system to override a state where the command would normally be denied
•NORM
Execute the command normally. Do not override any conditions that might make the command fail
PST
Primary state
Parameter type is PST—indicates the current overall service condition of an entity
•IS
In service
•OOS
Out of service
SST
Secondary state
Parameter type is SST—provides additional information pertaining to PST and PSTQ
•AINS
Automatic in service
•DSBLD
Disabled
•LPBK
Loopback
•MEA
Mismatch of equipment and attributes
•MT
Maintenance mode
•OOG
Out of group
•SWDL
Software downloading
•UAS
Unassigned
•UEQ
Unequipped
Posted: Mon Sep 3 11:18:29 PDT 2007
All contents are Copyright © 1992--2007 Cisco Systems, Inc. All rights reserved.
Important Notices and Privacy Statement.