Table Of Contents
NTP-A88 Modify Line Settings and PM Parameter Thresholds for Electrical Cards
NTP-A89 Modify Line Settings and PM Parameter Thresholds for Optical Cards
NTP-A118 Modify Alarm Interface Controller-International Settings
NTP-A91 Upgrade DS-1 and DS-3 Protect Cards from 1:1 Protection to 1:N Protection
NTP-A315 Modify Port Settings and PM Parameter Thresholds for FC_MR-4 Cards
NTP-A321 Change Card or PPM Service State
NTP-A322 Manage Pluggable Port Modules
NTP-A354 Set or Check Cross-Connect Mode for XC-VXC-10G Cards
Change Card Settings
This chapter explains how to change line provisioning, thresholds, service states, and line rates on Cisco ONS 15454 cards.
Before You Begin
Before performing any of the following procedures, investigate all alarms and clear any trouble conditions. Refer to the Cisco ONS 15454 Troubleshooting Guide as necessary.
This section lists the chapter procedures (NTPs). Turn to a procedure for applicable tasks (DLPs).
1. A88 Modify Line Settings and PM Parameter Thresholds for Electrical Cards—As needed, complete this procedure to change line and threshold settings for all electrical cards (EC-1, DS-1, DS-3, DS3i-N-12, and DS3XM).
2. A89 Modify Line Settings and PM Parameter Thresholds for Optical Cards—As needed, complete this procedure to change line and threshold settings for all optical cards.
3. A118 Modify Alarm Interface Controller-International Settings—As needed, complete this procedure to change external alarms and controls and/or orderwire settings.
4. A91 Upgrade DS-1 and DS-3 Protect Cards from 1:1 Protection to 1:N Protection—As needed, complete this procedure to change the protection type on DS-1 or DS-3 cards.
5. A315 Modify Port Settings and PM Parameter Thresholds for FC_MR-4 Cards—As needed, complete this procedure to change FC_MR-4 card port and threshold settings.
6. A321 Change Card or PPM Service State—As needed, complete this procedure to change the service state on a card or pluggable port module (PPM).
7. A322 Manage Pluggable Port Modules—As needed, complete this procedure to provision a multirate PPM, assign the optical line rate, change the optical line rate, and delete PPMs.
8. A354 Set or Check Cross-Connect Mode for XC-VXC-10G Cards—As needed, complete this procedure to provision the node's cross-connect mode if mixed mode grooming is required.
NTP-A88 Modify Line Settings and PM Parameter Thresholds for Electrical Cards
Caution Changing card settings can be service affecting. You should make all changes during a scheduled maintenance window.
Step 1 Complete the "DLP-A60 Log into CTC" task on page 17-65 at the node where you want to change the electrical card settings. If you are already logged in, proceed to Step 2.
Step 2 As needed, complete the "NTP-A108 Back Up the Database" procedure on page 15-4.
Step 3 Perform any of the following tasks as needed:
• DLP-A165 Change Line and Threshold Settings for a DS1-14 or DS1N-14 Card, page 18-28
• DLP-A166 Change Line and Threshold Settings for a DS3-12 or DS3N-12 Card, page 18-32
• DLP-A167 Change Line and Threshold Settings for a DS3E-12 or DS3N-12E Card, page 18-36
• DLP-A168 Change Line and Threshold Settings for the DS3XM-6 Card, page 18-40
• DLP-A387 Change Line and Threshold Settings for the DS3XM-12 Card, page 20-87
• DLP-A526 Change Line and Threshold Settings for the DS3i-N-12 Cards, page 22-22
• DLP-A388 Change Line and Threshold Settings for the DS3/EC1-48 Cards, page 20-93
• DLP-A169 Change Line and Threshold Settings for the EC1-12 Card, page 18-44
• DLP-A376 Change Line and Threshold Settings for the DS1/E1-56 Cards, page 20-60
Step 4 As needed, complete the "NTP-A108 Back Up the Database" procedure on page 15-4.
Stop. You have completed this procedure.
NTP-A89 Modify Line Settings and PM Parameter Thresholds for Optical Cards
Caution Changing card settings can be service affecting. You should make all changes during a scheduled maintenance window.
Step 1 Complete the "DLP-A60 Log into CTC" task on page 17-65 at the node where you want to change the OC-N card settings. If you are already logged in, proceed to Step 2.
Step 2 As needed, complete the "NTP-A108 Back Up the Database" procedure on page 15-4.
Step 3 Perform any of the following tasks as needed:
• DLP-A379 Change Line Transmission Settings for OC-N Cards, page 20-71
• DLP-A171 Change Threshold Settings for OC-N Cards, page 18-48
• DLP-A459 Change Optics Thresholds Settings for OC-192 and MRC-12 Cards, page 21-36
• DLP-A172 Change an Optical Port to SDH, page 18-50
Step 4 As needed, complete the "NTP-A108 Back Up the Database" procedure on page 15-4.
Stop. You have completed this procedure.
NTP-A118 Modify Alarm Interface Controller-International Settings
Step 1 Complete the "DLP-A60 Log into CTC" task on page 17-65 at the node where you want to change the AIC-I card settings. If you are already logged in, continue with Step 2.
Step 2 As needed, complete the "NTP-A108 Back Up the Database" procedure on page 15-4.
Step 3 Perform any of the following tasks as needed:
• DLP-A208 Change External Alarms Using the AIC-I Card, page 19-6
• DLP-A209 Change External Controls Using the AIC-I Card, page 19-7
• DLP-A210 Change AIC-I Card Orderwire Settings, page 19-8
Step 4 As needed, complete the "NTP-A108 Back Up the Database" procedure on page 15-4.
Stop. You have completed this procedure.
NTP-A91 Upgrade DS-1 and DS-3 Protect Cards from 1:1 Protection to 1:N Protection
Step 1 Complete the "DLP-A60 Log into CTC" task on page 17-65 at the node where you want to convert the DS-1 or DS-3 cards from 1:1 to 1:N protection. If you are already logged in, continue with Step 2.
Step 2 As needed, complete the "NTP-A108 Back Up the Database" procedure on page 15-4.
Step 3 Perform any of the following tasks as needed:
• DLP-A176 Convert DS1-14 Cards From 1:1 to 1:N Protection, page 18-51
• DLP-A177 Convert DS3-12 Cards From 1:1 to 1:N Protection, page 18-52
• DLP-A178 Convert DS3-12E Cards From 1:1 to 1:N Protection, page 18-54
• DLP-A448 Convert DS3XM-6 or DS3XM-12 Cards From 1:1 to 1:N Protection, page 21-29
Step 4 As needed, complete the "NTP-A108 Back Up the Database" procedure on page 15-4.
Stop. You have completed this procedure.
NTP-A315 Modify Port Settings and PM Parameter Thresholds for FC_MR-4 Cards
Caution Changing card settings can be service affecting. You should make all changes during a scheduled maintenance window.
Step 1 Complete the "DLP-A60 Log into CTC" task on page 17-65 at the node where you want to change the OC-N card settings. If you are already logged in, continue with Step 2.
Step 2 As needed, complete the "NTP-A108 Back Up the Database" procedure on page 15-4.
Step 3 Perform any of the following tasks as needed:
• DLP-A438 Change General Port Settings for the FC_MR-4 Card, page 21-16
• DLP-A439 Change Distance Extension Port Settings for the FC_MR-4 Card, page 21-18
• DLP-A440 Change Enhanced FC/FICON Port Settings for the FC_MR-4 Card, page 21-20
• DLP-A357 Create FC_MR-4 RMON Alarm Thresholds, page 20-40
• DLP-A358 Delete FC_MR-4 RMON Alarm Thresholds, page 20-44
Step 4 As needed, complete the "NTP-A108 Back Up the Database" procedure on page 15-4.
Stop. You have completed this procedure.
NTP-A321 Change Card or PPM Service State
Note On the OC192-XFP and MRC-12 cards, the pluggable-port module (PPM) is equivalent to an optical port.
Step 1 Complete the "DLP-A60 Log into CTC" task on page 17-65 at the node where you want to change the card service state.
Step 2 From node view, click the Inventory tab.
Step 3 Choose an Admin state from the Admin State drop-down list for the card or PPM that you want to change: IS (In-Service) or OOS,MT (Out-of-Service,Maintenance).
Step 4 Click Apply.
Step 5 If an error message appears indicating that the card state cannot be changed from its current state, click OK.
Depending on the Admin State you choose, the card or port/PPM transitions to a different service state. For more information about the service states and card state transitions, refer to the "Administrative and Service States" appendix of the Cisco ONS 15454 Reference Manual.
Stop. You have completed this procedure.
NTP-A322 Manage Pluggable Port Modules
Purpose
This procedure provisions, changes, and deletes pluggable port modules (PPMs) for the MRC-12 and OC192-XFP cards. (OC-192XFPs are single-rate PPMs, and therefore can only be deleted.)
Tools/Equipment
None
Prerequisite Procedures
DLP-A461 Preprovision an SFP or XFP Device, page 21-38 or
Required/As Needed
As needed
Onsite/Remote
Onsite or remote
Security Level
Provisioning or higher
Step 1 Complete the "DLP-A60 Log into CTC" task on page 17-65 at the node where you want to provision, change, or delete PPMs. If you are already logged in, continue with Step 2.
Step 2 From the View menu, choose Go to Network View.
Step 3 Click the Alarms tab:
a. Verify that the alarm filter is not turned on. See the "DLP-A227 Disable Alarm Filtering" task on page 19-18 as necessary.
b. Verify that no unexplained conditions appear on the network. If unexplained conditions appear, resolve them before continuing. Refer to the Cisco ONS 15454 Troubleshooting Guide.
c. Complete the "DLP-A532 Export CTC Data" task on page 22-30 to export alarm and condition information.
Step 4 As needed, complete the "DLP-A444 Provision a PPM on the MRC-12 Card" task on page 21-25. Single-rate PPMs do not require provisioning.
Step 5 As needed, complete the "DLP-A445 Provision the Optical Line Rate on the MRC-12 Card" task on page 21-26 to assign an OC-3, OC-12, or OC-48 line rate to a multirate PPM.
Step 6 As needed, complete the "DLP-A446 Change the Optical Line Rate on the MRC-12 Card" task on page 21-27 to change the line rate on a multirate PPM. You cannot change the optical line rate on single-rate PPMs.
Step 7 As needed, complete the "DLP-A447 Delete a PPM from the MRC-12 or OC192-XFP Card" task on page 21-28.
Stop. You have completed this procedure.
NTP-A354 Set or Check Cross-Connect Mode for XC-VXC-10G Cards
Step 1 Complete the "DLP-A60 Log into CTC" task on page 17-65 at the node where you want to change the XC-VXC-10G card settings. If you are already logged in, continue with Step 2.
Step 2 Navigate to the node view in CTC.
Step 3 Click Provisioning > Cross-Connect. The Cross-Connect dialog box is displayed.
Step 4 If necessary, click the Mixed Mode radio button in the Cross-Connect dialog box and click Apply.
Stop. You have completed this procedure.