Table Of Contents
Network Element Defaults
D.1 Network Element Defaults Description
D.2 ANSI Platform Defaults
D.2.1 ANSI Card Default Settings
D.2.2 ANSI Node Default Settings
D.2.3 ANSI CTC Default Settings
D.3 ETSI Platform Defaults
D.3.1 ETSI Card Default Settings
D.3.2 ETSI Node Default Settings
D.3.3 ETSI CTC Default Settings
Network Element Defaults
Note The terms "Unidirectional Path Switched Ring" and "UPSR" may appear in Cisco literature. These terms do not refer to using Cisco ONS 15xxx products in a unidirectional path switched ring configuration. Rather, these terms, as well as "Path Protected Mesh Network" and "PPMN," refer generally to Cisco's path protection feature, which may be used in any topological network configuration. Cisco does not recommend using its path protection feature in any particular topological network configuration.
This appendix describes the factory-configured (default) network element (NE) settings for the Cisco ONS 15454. It includes descriptions of card, node, and Cisco Transport Controller (CTC) default settings. To import, export, or edit the settings, see Chapter 13, "Maintain the Node." Cards supported by this platform that are not listed in this appendix are not supported by user-configurable NE defaults settings.
To change card settings individually (that is, without changing the defaults), see "Provision Transponder and Muxponder Cards." To change node settings, see Chapter 10, "Manage the Node."
Note Unless otherwise specified, in this appendix "ONS 15454" refers to both ANSI (ONS 15454 SONET) and ETSI (ONS 15454 SDH) shelf assemblies.
D.1 Network Element Defaults Description
The NE defaults are preinstalled on each Cisco ONS 15454 TCC2 and TCC2P card. They also ship as a file called 15454-defaults.txt (ANSI shelves) or 15454SDH-defaults.txt (ETSI shelves) on the CTC software CD in case you want to import the defaults onto existing TCC2/TCC2P cards. The NE defaults include card-level, CTC, and node-level defaults.
Changes to card provisioning made manually using Change Card Settings procedures in "Provision Transponder and Muxponder Cards."override default settings. If you use the CTC Defaults editor (in the node view > Provisioning > Defaults tabs) or import a new defaults file, any changes to card or slot settings that result only affect cards that are installed or preprovisioned after the defaults have changed.
Changes made manually to most node-level default settings override the current settings, whether default or provisioned. If you change node-level default settings, either by using the Defaults editor or by importing a new defaults file, the new defaults reprovision the node immediately for all settings except those relating to protection (1+1 bidirectional switching, 1+1 reversion time, 1+1 revertive, Bidirectional Line Switched Ring [BLSR] or multiplex section-shared protection ring [MS-SPRing] reversion time, BLSR/MS-SPRing ring revertive, BLSR/MS-SPRing span reversion time, BLSR/MS-SPRing span revertive), which apply to subsequent provisioning.
Note Changing some NE defaults can cause CTC disconnection or a reboot of the node in order for the default to take effect. Before you change a default, check in the Side Effects column of the Defaults editor (right-click a column header and select Show Column > Side Effects) and be prepared for the occurrence of any side effects listed for that default.
D.2 ANSI Platform Defaults
The following sections give the NE defaults for the ONS 15454 ANSI platform. To see defaults for the ONS 15454 ETSI platform, see the "ETSI Platform Defaults" section.
D.2.1 ANSI Card Default Settings
The tables in this section list the default settings for each DWDM, TXP, and MXP card. For all other cards, including electrical, optical, Ethernet, and Fibre Channel, refer to the Cisco ONS 15454 Reference Manual.
Cisco provides user-configurable defaults for the Cisco ONS 15454 cards, including:
•Soak Time—All cards. The length of time that elapses between an automaticInService (AINS) port receiving a valid signal and when it automatically changes to in-service status.
•Port State—All cards. Sets the port to one of the four available states (IS, OOS, OOS_MT, or IS_AINS), depending on whether you need ports in or out of service.
•SF BER Level—TXP and MXP cards. Defines the signal fail (SF) bit error rate (BER).
•SD BER Level—TXP and MXP cards. Defines the signal degrade (SD) BER.
•Enable Sync Messages—MXP cards. Enables synchronization status messages (SSM) (S1 byte), which allow the node to choose the best timing source.
•Send Do Not Use—TXP and MXP cards. Sends a do not use (DUS) message on the S1 byte when enabled.
•Payload Type—TXP and MXP cards. Defines the type of client signal.
•Termination Mode—TXP and MXP cards. Defines the type of termination (line, section, or transparent).
•ALS Mode—TXP and MXP cards. Sets the automatic laser shutdown (ALS) feature to one of four available states (disabled, auto restart, manual restart, manual restart for test).
•ALS Recovery Interval—TXP and MXP cards. Sets the automatic laser shutdown recovery time interval.
•ALS Recovery Pulse Width—TXP and MXP cards. Sets the automatic laser shutdown recovery pulse signal width.
•FEC—TXP and MXP cards. Enables or disables the forward error correction (FEC) monitoring on the optical transport network.
•G.709 OTN—TXP and MXP cards. Enables or disables the ITU-T G.709 monitoring on the optical transport network.
•FEC Thresholds—TXP and MXP cards. Sets the performance monitoring (PM) parameters for gathering FEC performance data and detecting problems early.
•Optical Thresholds—TXP and MXP cards. Sets the PM parameters for gathering physical optics performance data and detecting problems early.
•OTN Thresholds—TXP and MXP cards. Sets the PM parameters for gathering OTN trunk-side performance data and detecting problems early.
•PM Threshold settings—All cards. Sets the PM parameters for gathering performance data and detecting problems early.
Note For more information about each individual card setting, see "Provision Transponder and Muxponder Cards."
Note For more information about the PM parameters, see Chapter 9, "Monitor Performance."
D.2.1.1 MXP_2.5G_10E Card Default Settings
Table D-1 lists the MXP_2.5G_10E card default settings.
Table D-1 MXP_2.5G_10E Card Default Settings (ANSI)
Default Name
|
Default Value
|
Default Domain
|
MXP-2_5G-10E.config.client.AINSSoakTime
|
08:00 (hours:mins)
|
00:00, 00:15, 00:30 .. 48:00
|
MXP-2_5G-10E.config.client.AisSquelchMode
|
Squelch
|
Ais, Squelch
|
MXP-2_5G-10E.config.client.AlsMode
|
Disabled
|
Disabled, Auto Restart, Manual Restart, Manual Restart for Test
|
MXP-2_5G-10E.config.client.AlsRecoveryPulseDuration
|
2.0 (seconds)
|
•2.0, 2.1, 2.2 .. 100.0 when AlsMode is Disabled, Auto Restart, Manual Restart
•80.0, 80.1, 80.2 .. 100.0 when AlsMode is Manual Restart for Test
|
MXP-2_5G-10E.config.client.AlsRecoveryPulseInterval
|
100 (seconds)
|
100-2000
|
MXP-2_5G-10E.config.client.ppmPortAssignment
|
OC48_PORT
|
UNASSIGNED, OC48_PORT
|
MXP-2_5G-10E.config.client.ppmSlotAssignment
|
UNASSIGNED
|
UNASSIGNED, PPM (1 Port)
|
MXP-2_5G-10E.config.client.SDBER
|
1.00E-07
|
1E-5, 1E-6, 1E-7, 1E-8, 1E-9
|
MXP-2_5G-10E.config.client.SendDoNotUse
|
FALSE
|
TRUE, FALSE
|
MXP-2_5G-10E.config.client.SFBER
|
1.00E-04
|
1E-3, 1E-4, 1E-5
|
MXP-2_5G-10E.config.client.SyncMsgIn
|
TRUE
|
FALSE, TRUE
|
MXP-2_5G-10E.config.client.TerminationMode
|
Transparent
|
Transparent, Section
|
MXP-2_5G-10E.config.trunk.AINSSoakTime
|
08:00 (hours:mins)
|
00:00, 00:15, 00:30 .. 48:00
|
MXP-2_5G-10E.config.trunk.AlsMode
|
Disabled
|
Disabled, Auto Restart, Manual Restart, Manual Restart for Test
|
MXP-2_5G-10E.config.trunk.AlsRecoveryPulseDuration
|
100.0 (seconds)
|
•60.0, 60.1, 60.2 .. 200.0 when AlsMode is Disabled, Auto Restart, Manual Restart
•80.0, 80.1, 80.2 .. 100.0 when AlsMode is Manual Restart for Test
|
MXP-2_5G-10E.config.trunk.AlsRecoveryPulseInterval
|
300 (seconds)
|
200-2000
|
MXP-2_5G-10E.opticalthresholds.client.alarm.HighLaserBias
|
90.0 (%)
|
0.0, 0.1, 0.2 .. 100.0
|
MXP-2_5G-10E.opticalthresholds.client.alarm.HighRxPower
|
3.0 (dBm)
|
-21.0, -20.9, -20.8 .. 30.0
|
MXP-2_5G-10E.opticalthresholds.client.alarm.HighTxPower
|
3.0 (dBm)
|
-8.0, -7.9, -7.8 .. 30.0
|
MXP-2_5G-10E.opticalthresholds.client.alarm.LowRxPower
|
-21.0 (dBm)
|
-40.0, -39.9, -39.8 .. 3.0
|
MXP-2_5G-10E.opticalthresholds.client.alarm.LowTxPower
|
-8.0 (dBm)
|
-40.0, -39.9, -39.8 .. 3.0
|
MXP-2_5G-10E.opticalthresholds.client.warning.15min.HighLaserBias
|
81.0 (%)
|
0.0, 0.1, 0.2 .. 100.0
|
MXP-2_5G-10E.opticalthresholds.client.warning.15min.HighRxPower
|
2.0 (dBm)
|
-20.0, -19.9, -19.8 .. 30.0
|
MXP-2_5G-10E.opticalthresholds.client.warning.15min.HighTxPower
|
2.0 (dBm)
|
-7.0, -6.9, -6.8 .. 30.0
|
MXP-2_5G-10E.opticalthresholds.client.warning.15min.LowRxPower
|
-20.0 (dBm)
|
-40.0, -39.9, -39.8 .. 2.0
|
MXP-2_5G-10E.opticalthresholds.client.warning.15min.LowTxPower
|
-7.0 (dBm)
|
-40.0, -39.9, -39.8 .. 2.0
|
MXP-2_5G-10E.opticalthresholds.client.warning.1day.HighLaserBias
|
85.5 (%)
|
0.0, 0.1, 0.2 .. 100.0
|
MXP-2_5G-10E.opticalthresholds.client.warning.1day.HighRxPower
|
2.5 (dBm)
|
-20.5, -20.4, -20.3 .. 30.0
|
MXP-2_5G-10E.opticalthresholds.client.warning.1day.HighTxPower
|
2.5 (dBm)
|
-7.5, -7.4, -7.3 .. 30.0
|
MXP-2_5G-10E.opticalthresholds.client.warning.1day.LowRxPower
|
-20.5 (dBm)
|
-40.0, -39.9, -39.8 .. 2.5
|
MXP-2_5G-10E.opticalthresholds.client.warning.1day.LowTxPower
|
-7.5 (dBm)
|
-40.0, -39.9, -39.8 .. 2.5
|
MXP-2_5G-10E.opticalthresholds.trunk.alarm.HighLaserBias
|
98.0 (%)
|
0.0, 0.1, 0.2 .. 100.0
|
MXP-2_5G-10E.opticalthresholds.trunk.alarm.HighRxPower
|
-8.0 (dBm)
|
-25.0, -24.9, -24.8 .. 30.0
|
MXP-2_5G-10E.opticalthresholds.trunk.alarm.HighTxPower
|
8.0 (dBm)
|
1.0, 1.1, 1.2 .. 30.0
|
MXP-2_5G-10E.opticalthresholds.trunk.alarm.LowRxPower
|
-25.0 (dBm)
|
-40.0, -39.9, -39.8 .. -8.0
|
MXP-2_5G-10E.opticalthresholds.trunk.alarm.LowTxPower
|
1.0 (dBm)
|
-40.0, -39.9, -39.8 .. 8.0
|
MXP-2_5G-10E.opticalthresholds.trunk.warning.15min.HighLaserBias
|
95.0 (%)
|
0.0, 0.1, 0.2 .. 100.0
|
MXP-2_5G-10E.opticalthresholds.trunk.warning.15min.HighRxPower
|
-7.5 (dBm)
|
-24.5, -24.4, -24.3 .. 30.0
|
MXP-2_5G-10E.opticalthresholds.trunk.warning.15min.HighTxPower
|
7.0 (dBm)
|
2.0, 2.1, 2.2 .. 30.0
|
MXP-2_5G-10E.opticalthresholds.trunk.warning.15min.LowRxPower
|
-24.5 (dBm)
|
-40.0, -39.9, -39.8 .. -7.5
|
MXP-2_5G-10E.opticalthresholds.trunk.warning.15min.LowTxPower
|
2.0 (dBm)
|
-40.0, -39.9, -39.8 .. 7.0
|
MXP-2_5G-10E.opticalthresholds.trunk.warning.1day.HighLaserBias
|
96.0 (%)
|
0.0, 0.1, 0.2 .. 100.0
|
MXP-2_5G-10E.opticalthresholds.trunk.warning.1day.HighRxPower
|
-7.3 (dBm)
|
-24.7, -24.6, -24.5 .. 30.0
|
MXP-2_5G-10E.opticalthresholds.trunk.warning.1day.HighTxPower
|
7.0 (dBm)
|
2.0, 2.1, 2.2 .. 30.0
|
MXP-2_5G-10E.opticalthresholds.trunk.warning.1day.LowRxPower
|
-24.7 (dBm)
|
-40.0, -39.9, -39.8 .. -7.3
|
MXP-2_5G-10E.opticalthresholds.trunk.warning.1day.LowTxPower
|
2.0 (dBm)
|
-40.0, -39.9, -39.8 .. 7.0
|
MXP-2_5G-10E.otn.fecthresholds.enhanced.15min.BitErrorsCorrected
|
903330 (count)
|
0-9033621811200
|
MXP-2_5G-10E.otn.fecthresholds.enhanced.15min.UncorrectableWords
|
5 (count)
|
0-4724697600
|
MXP-2_5G-10E.otn.fecthresholds.enhanced.1day.BitErrorsCorrected
|
86719680 (count)
|
0-867227693875200
|
MXP-2_5G-10E.otn.fecthresholds.enhanced.1day.UncorrectableWords
|
480 (count)
|
0-453570969600
|
MXP-2_5G-10E.otn.fecthresholds.standard.15min.BitErrorsCorrected
|
903330 (count)
|
0-9033621811200
|
MXP-2_5G-10E.otn.fecthresholds.standard.15min.UncorrectableWords
|
5 (count)
|
0-4724697600
|
MXP-2_5G-10E.otn.fecthresholds.standard.1day.BitErrorsCorrected
|
86719680 (count)
|
0-867227693875200
|
MXP-2_5G-10E.otn.fecthresholds.standard.1day.UncorrectableWords
|
480 (count)
|
0-453570969600
|
MXP-2_5G-10E.otn.g709thresholds.pm.farend.15min.BBE
|
85040 (count)
|
0-8850600
|
MXP-2_5G-10E.otn.g709thresholds.pm.farend.15min.ES
|
87 (seconds)
|
0-900
|
MXP-2_5G-10E.otn.g709thresholds.pm.farend.15min.FC
|
10 (count)
|
0-72
|
MXP-2_5G-10E.otn.g709thresholds.pm.farend.15min.SES
|
1 (seconds)
|
0-900
|
MXP-2_5G-10E.otn.g709thresholds.pm.farend.15min.UAS
|
3 (seconds)
|
0-900
|
MXP-2_5G-10E.otn.g709thresholds.pm.farend.1day.BBE
|
850400 (count)
|
0-849657600
|
MXP-2_5G-10E.otn.g709thresholds.pm.farend.1day.ES
|
864 (seconds)
|
0-86400
|
MXP-2_5G-10E.otn.g709thresholds.pm.farend.1day.FC
|
40 (count)
|
0-6912
|
MXP-2_5G-10E.otn.g709thresholds.pm.farend.1day.SES
|
4 (seconds)
|
0-86400
|
MXP-2_5G-10E.otn.g709thresholds.pm.farend.1day.UAS
|
10 (seconds)
|
0-86400
|
MXP-2_5G-10E.otn.g709thresholds.pm.nearend.15min.BBE
|
85040 (count)
|
0-8850600
|
MXP-2_5G-10E.otn.g709thresholds.pm.nearend.15min.ES
|
87 (seconds)
|
0-900
|
MXP-2_5G-10E.otn.g709thresholds.pm.nearend.15min.FC
|
10 (count)
|
0-72
|
MXP-2_5G-10E.otn.g709thresholds.pm.nearend.15min.SES
|
1 (seconds)
|
0-900
|
MXP-2_5G-10E.otn.g709thresholds.pm.nearend.15min.UAS
|
3 (seconds)
|
0-900
|
MXP-2_5G-10E.otn.g709thresholds.pm.nearend.1day.BBE
|
850400 (count)
|
0-849657600
|
MXP-2_5G-10E.otn.g709thresholds.pm.nearend.1day.ES
|
864 (seconds)
|
0-86400
|
MXP-2_5G-10E.otn.g709thresholds.pm.nearend.1day.FC
|
40 (count)
|
0-6912
|
MXP-2_5G-10E.otn.g709thresholds.pm.nearend.1day.SES
|
4 (seconds)
|
0-86400
|
MXP-2_5G-10E.otn.g709thresholds.pm.nearend.1day.UAS
|
10 (seconds)
|
0-86400
|
MXP-2_5G-10E.otn.g709thresholds.sm.farend.15min.BBE
|
10000 (count)
|
0-8850600
|
MXP-2_5G-10E.otn.g709thresholds.sm.farend.15min.ES
|
500 (seconds)
|
0-900
|
MXP-2_5G-10E.otn.g709thresholds.sm.farend.15min.FC
|
10 (count)
|
0-72
|
MXP-2_5G-10E.otn.g709thresholds.sm.farend.15min.SES
|
500 (seconds)
|
0-900
|
MXP-2_5G-10E.otn.g709thresholds.sm.farend.15min.UAS
|
500 (seconds)
|
0-900
|
MXP-2_5G-10E.otn.g709thresholds.sm.farend.1day.BBE
|
100000 (count)
|
0-849657600
|
MXP-2_5G-10E.otn.g709thresholds.sm.farend.1day.ES
|
5000 (seconds)
|
0-86400
|
MXP-2_5G-10E.otn.g709thresholds.sm.farend.1day.FC
|
40 (count)
|
0-6912
|
MXP-2_5G-10E.otn.g709thresholds.sm.farend.1day.SES
|
5000 (seconds)
|
0-86400
|
MXP-2_5G-10E.otn.g709thresholds.sm.farend.1day.UAS
|
5000 (seconds)
|
0-86400
|
MXP-2_5G-10E.otn.g709thresholds.sm.nearend.15min.BBE
|
10000 (count)
|
0-8850600
|
MXP-2_5G-10E.otn.g709thresholds.sm.nearend.15min.ES
|
500 (seconds)
|
0-900
|
MXP-2_5G-10E.otn.g709thresholds.sm.nearend.15min.FC
|
10 (count)
|
0-72
|
MXP-2_5G-10E.otn.g709thresholds.sm.nearend.15min.SES
|
500 (seconds)
|
0-900
|
MXP-2_5G-10E.otn.g709thresholds.sm.nearend.15min.UAS
|
500 (seconds)
|
0-900
|
MXP-2_5G-10E.otn.g709thresholds.sm.nearend.1day.BBE
|
100000 (count)
|
0-849657600
|
MXP-2_5G-10E.otn.g709thresholds.sm.nearend.1day.ES
|
5000 (seconds)
|
0-86400
|
MXP-2_5G-10E.otn.g709thresholds.sm.nearend.1day.FC
|
40 (count)
|
0-6912
|
MXP-2_5G-10E.otn.g709thresholds.sm.nearend.1day.SES
|
5000 (seconds)
|
0-86400
|
MXP-2_5G-10E.otn.g709thresholds.sm.nearend.1day.UAS
|
5000 (seconds)
|
0-86400
|
MXP-2_5G-10E.otn.otnLines.AsynchSynchMapping
|
ODU Multiplex
|
ODU Multiplex
|
MXP-2_5G-10E.otn.otnLines.FEC
|
Standard
|
Disable, Standard, Enhanced
|
MXP-2_5G-10E.otn.otnLines.G709OTN
|
Enable
|
Enable
|
MXP-2_5G-10E.otn.otnLines.SDBER
|
1.00E-07
|
1E-5, 1E-6, 1E-7, 1E-8, 1E-9
|
MXP-2_5G-10E.pmthresholds.client.line.farend.15min.CV
|
21260 (B2 count)
|
0-2212200
|
MXP-2_5G-10E.pmthresholds.client.line.farend.15min.ES
|
87 (seconds)
|
0-900
|
MXP-2_5G-10E.pmthresholds.client.line.farend.15min.FC
|
10 (count)
|
0-72
|
MXP-2_5G-10E.pmthresholds.client.line.farend.15min.SES
|
1 (seconds)
|
0-900
|
MXP-2_5G-10E.pmthresholds.client.line.farend.15min.UAS
|
3 (seconds)
|
0-900
|
MXP-2_5G-10E.pmthresholds.client.line.farend.1day.CV
|
212600 (B2 count)
|
0-212371200
|
MXP-2_5G-10E.pmthresholds.client.line.farend.1day.ES
|
864 (seconds)
|
0-86400
|
MXP-2_5G-10E.pmthresholds.client.line.farend.1day.FC
|
40 (count)
|
0-6912
|
MXP-2_5G-10E.pmthresholds.client.line.farend.1day.SES
|
4 (seconds)
|
0-86400
|
MXP-2_5G-10E.pmthresholds.client.line.farend.1day.UAS
|
10 (seconds)
|
0-86400
|
MXP-2_5G-10E.pmthresholds.client.line.nearend.15min.CV
|
21260 (B2 count)
|
0-2212200
|
MXP-2_5G-10E.pmthresholds.client.line.nearend.15min.ES
|
87 (seconds)
|
0-900
|
MXP-2_5G-10E.pmthresholds.client.line.nearend.15min.FC
|
10 (count)
|
0-72
|
MXP-2_5G-10E.pmthresholds.client.line.nearend.15min.SES
|
1 (seconds)
|
0-900
|
MXP-2_5G-10E.pmthresholds.client.line.nearend.15min.UAS
|
3 (seconds)
|
0-900
|
MXP-2_5G-10E.pmthresholds.client.line.nearend.1day.CV
|
212600 (B2 count)
|
0-212371200
|
MXP-2_5G-10E.pmthresholds.client.line.nearend.1day.ES
|
864 (seconds)
|
0-86400
|
MXP-2_5G-10E.pmthresholds.client.line.nearend.1day.FC
|
40 (count)
|
0-6912
|
MXP-2_5G-10E.pmthresholds.client.line.nearend.1day.SES
|
4 (seconds)
|
0-86400
|
MXP-2_5G-10E.pmthresholds.client.line.nearend.1day.UAS
|
10 (seconds)
|
0-86400
|
MXP-2_5G-10E.pmthresholds.client.section.nearend.15min.CV
|
10000 (B1 count)
|
0-2151900
|
MXP-2_5G-10E.pmthresholds.client.section.nearend.15min.ES
|
500 (seconds)
|
0-900
|
MXP-2_5G-10E.pmthresholds.client.section.nearend.15min.SEFS
|
500 (seconds)
|
0-900
|
MXP-2_5G-10E.pmthresholds.client.section.nearend.15min.SES
|
500 (seconds)
|
0-900
|
MXP-2_5G-10E.pmthresholds.client.section.nearend.1day.CV
|
100000 (B1 count)
|
0-206582400
|
MXP-2_5G-10E.pmthresholds.client.section.nearend.1day.ES
|
5000 (seconds)
|
0-86400
|
MXP-2_5G-10E.pmthresholds.client.section.nearend.1day.SEFS
|
5000 (seconds)
|
0-86400
|
MXP-2_5G-10E.pmthresholds.client.section.nearend.1day.SES
|
5000 (seconds)
|
0-86400
|
D.2.1.2 MXP_2.5G_10G Card Default Settings
Table D-2 lists the MXP_2.5G_10G card default settings.
Table D-2 MXP_2.5G_10G Card Default Settings (ANSI)
Default Name
|
Default Value
|
Default Domain
|
MXP-2_5G-10G.config.client.AINSSoakTime
|
08:00 (hours:mins)
|
00:00, 00:15, 00:30 .. 48:00
|
MXP-2_5G-10G.config.client.AlsMode
|
Disabled
|
Disabled, Auto Restart, Manual Restart, Manual Restart for Test
|
MXP-2_5G-10G.config.client.AlsRecoveryPulseDuration
|
4.0 (seconds)
|
•2.0, 2.1, 2.2 .. 100.0 when AlsMode is Disabled, Auto Restart, Manual Restart
•80.0, 80.1, 80.2 .. 100.0 when AlsMode is Manual Restart for Test
|
MXP-2_5G-10G.config.client.AlsRecoveryPulseInterval
|
100 (seconds)
|
60-300
|
MXP-2_5G-10G.config.client.ppmPortAssignment
|
OC48_PORT
|
UNASSIGNED, OC48_PORT
|
MXP-2_5G-10G.config.client.ppmSlotAssignment
|
UNASSIGNED
|
UNASSIGNED, PPM (1 Port)
|
MXP-2_5G-10G.config.client.SDBER
|
1.00E-07
|
1E-5, 1E-6, 1E-7, 1E-8, 1E-9
|
MXP-2_5G-10G.config.client.SendDoNotUse
|
FALSE
|
TRUE, FALSE
|
MXP-2_5G-10G.config.client.SFBER
|
1.00E-04
|
1E-3, 1E-4, 1E-5
|
MXP-2_5G-10G.config.client.SyncMsgIn
|
TRUE
|
FALSE, TRUE
|
MXP-2_5G-10G.config.client.TerminationMode
|
Transparent
|
Transparent, Line
|
MXP-2_5G-10G.config.trunk.AINSSoakTime
|
08:00 (hours:mins)
|
00:00, 00:15, 00:30 .. 48:00
|
MXP-2_5G-10G.config.trunk.AlsMode
|
Disabled
|
Disabled, Auto Restart, Manual Restart, Manual Restart for Test
|
MXP-2_5G-10G.config.trunk.AlsRecoveryPulseDuration
|
4.0 (seconds)
|
•2.0, 2.1, 2.2 .. 100.0 when AlsMode is Disabled, Auto Restart, Manual Restart
•80.0, 80.1, 80.2 .. 100.0 when AlsMode is Manual Restart for Test
|
MXP-2_5G-10G.config.trunk.AlsRecoveryPulseInterval
|
100 (seconds)
|
60-300
|
MXP-2_5G-10G.opticalthresholds.client.alarm.HighLaserBias
|
90.0 (%)
|
0.0, 0.1, 0.2 .. 100.0
|
MXP-2_5G-10G.opticalthresholds.client.alarm.HighRxPower
|
3.0 (dBm)
|
LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0
|
MXP-2_5G-10G.opticalthresholds.client.alarm.HighTxPower
|
3.0 (dBm)
|
LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0
|
MXP-2_5G-10G.opticalthresholds.client.alarm.LowRxPower
|
-21.0 (dBm)
|
-40.0, -39.9, -39.8 .. HighRxPower
|
MXP-2_5G-10G.opticalthresholds.client.alarm.LowTxPower
|
-8.0 (dBm)
|
-40.0, -39.9, -39.8 .. HighTxPower
|
MXP-2_5G-10G.opticalthresholds.client.warning.15min.HighLaserBias
|
81.0 (%)
|
0.0, 0.1, 0.2 .. 100.0
|
MXP-2_5G-10G.opticalthresholds.client.warning.15min.HighRxPower
|
2.0 (dBm)
|
LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0
|
MXP-2_5G-10G.opticalthresholds.client.warning.15min.HighTxPower
|
2.0 (dBm)
|
LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0
|
MXP-2_5G-10G.opticalthresholds.client.warning.15min.LowRxPower
|
-20.0 (dBm)
|
-40.0, -39.9, -39.8 .. HighRxPower
|
MXP-2_5G-10G.opticalthresholds.client.warning.15min.LowTxPower
|
-7.0 (dBm)
|
-40.0, -39.9, -39.8 .. HighTxPower
|
MXP-2_5G-10G.opticalthresholds.client.warning.1day.HighLaserBias
|
85.5 (%)
|
0.0, 0.1, 0.2 .. 100.0
|
MXP-2_5G-10G.opticalthresholds.client.warning.1day.HighRxPower
|
2.5 (dBm)
|
LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0
|
MXP-2_5G-10G.opticalthresholds.client.warning.1day.HighTxPower
|
2.5 (dBm)
|
LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0
|
MXP-2_5G-10G.opticalthresholds.client.warning.1day.LowRxPower
|
-20.5 (dBm)
|
-40.0, -39.9, -39.8 .. HighRxPower
|
MXP-2_5G-10G.opticalthresholds.client.warning.1day.LowTxPower
|
-7.5 (dBm)
|
-40.0, -39.9, -39.8 .. HighTxPower
|
MXP-2_5G-10G.opticalthresholds.trunk.alarm.HighLaserBias
|
90.0 (%)
|
0.0, 0.1, 0.2 .. 100.0
|
MXP-2_5G-10G.opticalthresholds.trunk.alarm.HighRxPower
|
-8.0 (dBm)
|
LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0
|
MXP-2_5G-10G.opticalthresholds.trunk.alarm.HighTxPower
|
4.0 (dBm)
|
LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0
|
MXP-2_5G-10G.opticalthresholds.trunk.alarm.LowRxPower
|
-25.0 (dBm)
|
-40.0, -39.9, -39.8 .. HighRxPower
|
MXP-2_5G-10G.opticalthresholds.trunk.alarm.LowTxPower
|
2.0 (dBm)
|
-40.0, -39.9, -39.8 .. HighTxPower
|
MXP-2_5G-10G.opticalthresholds.trunk.warning.15min.HighLaserBias
|
81.0 (%)
|
0.0, 0.1, 0.2 .. 100.0
|
MXP-2_5G-10G.opticalthresholds.trunk.warning.15min.HighRxPower
|
-7.5 (dBm)
|
LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0
|
MXP-2_5G-10G.opticalthresholds.trunk.warning.15min.HighTxPower
|
3.5 (dBm)
|
LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0
|
MXP-2_5G-10G.opticalthresholds.trunk.warning.15min.LowRxPower
|
-24.5 (dBm)
|
-40.0, -39.9, -39.8 .. HighRxPower
|
MXP-2_5G-10G.opticalthresholds.trunk.warning.15min.LowTxPower
|
2.5 (dBm)
|
-40.0, -39.9, -39.8 .. HighTxPower
|
MXP-2_5G-10G.opticalthresholds.trunk.warning.1day.HighLaserBias
|
85.5 (%)
|
0.0, 0.1, 0.2 .. 100.0
|
MXP-2_5G-10G.opticalthresholds.trunk.warning.1day.HighRxPower
|
-7.3 (dBm)
|
LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0
|
MXP-2_5G-10G.opticalthresholds.trunk.warning.1day.HighTxPower
|
3.7 (dBm)
|
LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0
|
MXP-2_5G-10G.opticalthresholds.trunk.warning.1day.LowRxPower
|
-24.7 (dBm)
|
-40.0, -39.9, -39.8 .. HighRxPower
|
MXP-2_5G-10G.opticalthresholds.trunk.warning.1day.LowTxPower
|
2.3 (dBm)
|
-40.0, -39.9, -39.8 .. HighTxPower
|
MXP-2_5G-10G.otn.fecthresholds.standard.15min.BitErrorsCorrected
|
903330 (count)
|
0-9033621811200
|
MXP-2_5G-10G.otn.fecthresholds.standard.15min.UncorrectableWords
|
5 (count)
|
0-4724697600
|
MXP-2_5G-10G.otn.fecthresholds.standard.1day.BitErrorsCorrected
|
86719680 (count)
|
0-867227693875200
|
MXP-2_5G-10G.otn.fecthresholds.standard.1day.UncorrectableWords
|
480 (count)
|
0-453570969600
|
MXP-2_5G-10G.otn.g709thresholds.pm.farend.15min.BBE
|
85040 (count)
|
0-8850600
|
MXP-2_5G-10G.otn.g709thresholds.pm.farend.15min.ES
|
87 (seconds)
|
0-900
|
MXP-2_5G-10G.otn.g709thresholds.pm.farend.15min.FC
|
10 (count)
|
0-72
|
MXP-2_5G-10G.otn.g709thresholds.pm.farend.15min.SES
|
1 (seconds)
|
0-900
|
MXP-2_5G-10G.otn.g709thresholds.pm.farend.15min.UAS
|
3 (seconds)
|
0-900
|
MXP-2_5G-10G.otn.g709thresholds.pm.farend.1day.BBE
|
850400 (count)
|
0-849657600
|
MXP-2_5G-10G.otn.g709thresholds.pm.farend.1day.ES
|
864 (seconds)
|
0-86400
|
MXP-2_5G-10G.otn.g709thresholds.pm.farend.1day.FC
|
40 (count)
|
0-6912
|
MXP-2_5G-10G.otn.g709thresholds.pm.farend.1day.SES
|
4 (seconds)
|
0-86400
|
MXP-2_5G-10G.otn.g709thresholds.pm.farend.1day.UAS
|
10 (seconds)
|
0-86400
|
MXP-2_5G-10G.otn.g709thresholds.pm.nearend.15min.BBE
|
85040 (count)
|
0-8850600
|
MXP-2_5G-10G.otn.g709thresholds.pm.nearend.15min.ES
|
87 (seconds)
|
0-900
|
MXP-2_5G-10G.otn.g709thresholds.pm.nearend.15min.FC
|
10 (count)
|
0-72
|
MXP-2_5G-10G.otn.g709thresholds.pm.nearend.15min.SES
|
1 (seconds)
|
0-900
|
MXP-2_5G-10G.otn.g709thresholds.pm.nearend.15min.UAS
|
3 (seconds)
|
0-900
|
MXP-2_5G-10G.otn.g709thresholds.pm.nearend.1day.BBE
|
850400 (count)
|
0-849657600
|
MXP-2_5G-10G.otn.g709thresholds.pm.nearend.1day.ES
|
864 (seconds)
|
0-86400
|
MXP-2_5G-10G.otn.g709thresholds.pm.nearend.1day.FC
|
40 (count)
|
0-6912
|
MXP-2_5G-10G.otn.g709thresholds.pm.nearend.1day.SES
|
4 (seconds)
|
0-86400
|
MXP-2_5G-10G.otn.g709thresholds.pm.nearend.1day.UAS
|
10 (seconds)
|
0-86400
|
MXP-2_5G-10G.otn.g709thresholds.sm.farend.15min.BBE
|
10000 (count)
|
0-8850600
|
MXP-2_5G-10G.otn.g709thresholds.sm.farend.15min.ES
|
500 (seconds)
|
0-900
|
MXP-2_5G-10G.otn.g709thresholds.sm.farend.15min.FC
|
10 (count)
|
0-72
|
MXP-2_5G-10G.otn.g709thresholds.sm.farend.15min.SES
|
500 (seconds)
|
0-900
|
MXP-2_5G-10G.otn.g709thresholds.sm.farend.15min.UAS
|
500 (seconds)
|
0-900
|
MXP-2_5G-10G.otn.g709thresholds.sm.farend.1day.BBE
|
100000 (count)
|
0-849657600
|
MXP-2_5G-10G.otn.g709thresholds.sm.farend.1day.ES
|
5000 (seconds)
|
0-86400
|
MXP-2_5G-10G.otn.g709thresholds.sm.farend.1day.FC
|
40 (count)
|
0-6912
|
MXP-2_5G-10G.otn.g709thresholds.sm.farend.1day.SES
|
5000 (seconds)
|
0-86400
|
MXP-2_5G-10G.otn.g709thresholds.sm.farend.1day.UAS
|
5000 (seconds)
|
0-86400
|
MXP-2_5G-10G.otn.g709thresholds.sm.nearend.15min.BBE
|
10000 (count)
|
0-8850600
|
MXP-2_5G-10G.otn.g709thresholds.sm.nearend.15min.ES
|
500 (seconds)
|
0-900
|
MXP-2_5G-10G.otn.g709thresholds.sm.nearend.15min.FC
|
10 (count)
|
0-72
|
MXP-2_5G-10G.otn.g709thresholds.sm.nearend.15min.SES
|
500 (seconds)
|
0-900
|
MXP-2_5G-10G.otn.g709thresholds.sm.nearend.15min.UAS
|
500 (seconds)
|
0-900
|
MXP-2_5G-10G.otn.g709thresholds.sm.nearend.1day.BBE
|
100000 (count)
|
0-849657600
|
MXP-2_5G-10G.otn.g709thresholds.sm.nearend.1day.ES
|
5000 (seconds)
|
0-86400
|
MXP-2_5G-10G.otn.g709thresholds.sm.nearend.1day.FC
|
40 (count)
|
0-6912
|
MXP-2_5G-10G.otn.g709thresholds.sm.nearend.1day.SES
|
5000 (seconds)
|
0-86400
|
MXP-2_5G-10G.otn.g709thresholds.sm.nearend.1day.UAS
|
5000 (seconds)
|
0-86400
|
MXP-2_5G-10G.otn.otnLines.FEC
|
Standard
|
•Disable, Standard, Enhanced when G709OTN is Enable
•Disable when G709OTN is Disable
|
MXP-2_5G-10G.otn.otnLines.G709OTN
|
Enable
|
Disable, Enable
|
MXP-2_5G-10G.otn.otnLines.SDBER
|
1.00E-07
|
1E-5, 1E-6, 1E-7, 1E-8, 1E-9
|
MXP-2_5G-10G.pmthresholds.client.line.farend.15min.CV
|
21260 (B2 count)
|
0-2212200
|
MXP-2_5G-10G.pmthresholds.client.line.farend.15min.ES
|
87 (seconds)
|
0-900
|
MXP-2_5G-10G.pmthresholds.client.line.farend.15min.FC
|
10 (count)
|
0-72
|
MXP-2_5G-10G.pmthresholds.client.line.farend.15min.SES
|
1 (seconds)
|
0-900
|
MXP-2_5G-10G.pmthresholds.client.line.farend.15min.UAS
|
3 (seconds)
|
0-900
|
MXP-2_5G-10G.pmthresholds.client.line.farend.1day.CV
|
212600 (B2 count)
|
0-212371200
|
MXP-2_5G-10G.pmthresholds.client.line.farend.1day.ES
|
864 (seconds)
|
0-86400
|
MXP-2_5G-10G.pmthresholds.client.line.farend.1day.FC
|
40 (count)
|
0-6912
|
MXP-2_5G-10G.pmthresholds.client.line.farend.1day.SES
|
4 (seconds)
|
0-86400
|
MXP-2_5G-10G.pmthresholds.client.line.farend.1day.UAS
|
10 (seconds)
|
0-86400
|
MXP-2_5G-10G.pmthresholds.client.line.nearend.15min.CV
|
21260 (B2 count)
|
0-2212200
|
MXP-2_5G-10G.pmthresholds.client.line.nearend.15min.ES
|
87 (seconds)
|
0-900
|
MXP-2_5G-10G.pmthresholds.client.line.nearend.15min.FC
|
10 (count)
|
0-72
|
MXP-2_5G-10G.pmthresholds.client.line.nearend.15min.SES
|
1 (seconds)
|
0-900
|
MXP-2_5G-10G.pmthresholds.client.line.nearend.15min.UAS
|
3 (seconds)
|
0-900
|
MXP-2_5G-10G.pmthresholds.client.line.nearend.1day.CV
|
212600 (B2 count)
|
0-212371200
|
MXP-2_5G-10G.pmthresholds.client.line.nearend.1day.ES
|
864 (seconds)
|
0-86400
|
MXP-2_5G-10G.pmthresholds.client.line.nearend.1day.FC
|
40 (count)
|
0-6912
|
MXP-2_5G-10G.pmthresholds.client.line.nearend.1day.SES
|
4 (seconds)
|
0-86400
|
MXP-2_5G-10G.pmthresholds.client.line.nearend.1day.UAS
|
10 (seconds)
|
0-86400
|
MXP-2_5G-10G.pmthresholds.client.section.nearend.15min.CV
|
10000 (B1 count)
|
0-2151900
|
MXP-2_5G-10G.pmthresholds.client.section.nearend.15min.ES
|
500 (seconds)
|
0-900
|
MXP-2_5G-10G.pmthresholds.client.section.nearend.15min.SEFS
|
500 (seconds)
|
0-900
|
MXP-2_5G-10G.pmthresholds.client.section.nearend.15min.SES
|
500 (seconds)
|
0-900
|
MXP-2_5G-10G.pmthresholds.client.section.nearend.1day.CV
|
100000 (B1 count)
|
0-206582400
|
MXP-2_5G-10G.pmthresholds.client.section.nearend.1day.ES
|
5000 (seconds)
|
0-86400
|
MXP-2_5G-10G.pmthresholds.client.section.nearend.1day.SEFS
|
5000 (seconds)
|
0-86400
|
MXP-2_5G-10G.pmthresholds.client.section.nearend.1day.SES
|
5000 (seconds)
|
0-86400
|
MXP-2_5G-10G.pmthresholds.trunk.line.farend.15min.CV
|
85040 (B2 count)
|
0-8850600
|
MXP-2_5G-10G.pmthresholds.trunk.line.farend.15min.ES
|
87 (seconds)
|
0-900
|
MXP-2_5G-10G.pmthresholds.trunk.line.farend.15min.FC
|
10 (count)
|
0-72
|
MXP-2_5G-10G.pmthresholds.trunk.line.farend.15min.SES
|
1 (seconds)
|
0-900
|
MXP-2_5G-10G.pmthresholds.trunk.line.farend.15min.UAS
|
3 (seconds)
|
0-900
|
MXP-2_5G-10G.pmthresholds.trunk.line.farend.1day.CV
|
850400 (B2 count)
|
0-849657600
|
MXP-2_5G-10G.pmthresholds.trunk.line.farend.1day.ES
|
864 (seconds)
|
0-86400
|
MXP-2_5G-10G.pmthresholds.trunk.line.farend.1day.FC
|
40 (count)
|
0-6912
|
MXP-2_5G-10G.pmthresholds.trunk.line.farend.1day.SES
|
4 (seconds)
|
0-86400
|
MXP-2_5G-10G.pmthresholds.trunk.line.farend.1day.UAS
|
10 (seconds)
|
0-86400
|
MXP-2_5G-10G.pmthresholds.trunk.line.nearend.15min.CV
|
85040 (B2 count)
|
0-8850600
|
MXP-2_5G-10G.pmthresholds.trunk.line.nearend.15min.ES
|
87 (seconds)
|
0-900
|
MXP-2_5G-10G.pmthresholds.trunk.line.nearend.15min.FC
|
10 (count)
|
0-72
|
MXP-2_5G-10G.pmthresholds.trunk.line.nearend.15min.SES
|
1 (seconds)
|
0-900
|
MXP-2_5G-10G.pmthresholds.trunk.line.nearend.15min.UAS
|
3 (seconds)
|
0-900
|
MXP-2_5G-10G.pmthresholds.trunk.line.nearend.1day.CV
|
850400 (B2 count)
|
0-849657600
|
MXP-2_5G-10G.pmthresholds.trunk.line.nearend.1day.ES
|
864 (seconds)
|
0-86400
|
MXP-2_5G-10G.pmthresholds.trunk.line.nearend.1day.FC
|
40 (count)
|
0-6912
|
MXP-2_5G-10G.pmthresholds.trunk.line.nearend.1day.SES
|
4 (seconds)
|
0-86400
|
MXP-2_5G-10G.pmthresholds.trunk.line.nearend.1day.UAS
|
10 (seconds)
|
0-86400
|
MXP-2_5G-10G.pmthresholds.trunk.section.nearend.15min.CV
|
10000 (B1 count)
|
0-7967700
|
MXP-2_5G-10G.pmthresholds.trunk.section.nearend.15min.ES
|
500 (seconds)
|
0-900
|
MXP-2_5G-10G.pmthresholds.trunk.section.nearend.15min.SEFS
|
500 (seconds)
|
0-900
|
MXP-2_5G-10G.pmthresholds.trunk.section.nearend.15min.SES
|
500 (seconds)
|
0-900
|
MXP-2_5G-10G.pmthresholds.trunk.section.nearend.1day.CV
|
100000 (B1 count)
|
0-764899200
|
MXP-2_5G-10G.pmthresholds.trunk.section.nearend.1day.ES
|
5000 (seconds)
|
0-86400
|
MXP-2_5G-10G.pmthresholds.trunk.section.nearend.1day.SEFS
|
5000 (seconds)
|
0-86400
|
MXP-2_5G-10G.pmthresholds.trunk.section.nearend.1day.SES
|
5000 (seconds)
|
0-86400
|
D.2.1.3 MXP_MR_2.5G Card Default Settings
Table D-3 lists the MXP_MR_2.5G card default settings.
Table D-3 MXP_MR_2.5G Card Default Settings (ANSI)
Default Name
|
Default Value
|
Default Domain
|
MXP-MR-2_5G.config.client.AlsMode
|
Disabled
|
Disabled, Manual Restart, Manual Restart for Test
|
MXP-MR-2_5G.config.client.AlsRecoveryPulseDuration
|
4.0 (seconds)
|
•2.0, 2.1, 2.2 .. 100.0 when AlsMode is Disabled, Auto Restart, Manual Restart
•80.0, 80.1, 80.2 .. 100.0 when AlsMode is Manual Restart for Test
|
MXP-MR-2_5G.config.client.AlsRecoveryPulseInterval
|
100 (seconds)
|
60-300
|
MXP-MR-2_5G.config.client.ppmPortAssignment
|
UNASSIGNED
|
UNASSIGNED, ONE_GE, FC1G ISL, FC2G ISL, FICON1G ISL, FICON2G ISL
|
MXP-MR-2_5G.config.client.ppmSlotAssignment
|
UNASSIGNED
|
UNASSIGNED, PPM (1 Port)
|
MXP-MR-2_5G.config.fc.distanceExtension.AutoadjustGFPBufferThreshold
|
TRUE
|
TRUE, FALSE
|
MXP-MR-2_5G.config.fc.distanceExtension.AutoDetect
|
TRUE
|
TRUE, FALSE
|
MXP-MR-2_5G.config.fc.distanceExtension.Enabled
|
TRUE
|
TRUE, FALSE
|
MXP-MR-2_5G.config.fc.distanceExtension.NumCredits
|
32
|
2-256
|
MXP-MR-2_5G.config.fc.distanceExtension.NumGFPBuffers
|
16
|
16, 32, 48 .. 1200
|
MXP-MR-2_5G.config.fc.enhancedFibreChannelFicon.MaxFrameSize
|
2148
|
2148, 2152, 2156, 2160, 2164, 2168, 2172
|
MXP-MR-2_5G.config.trunk.AINSSoakTime
|
08:00 (hours:mins)
|
00:00, 00:15, 00:30 .. 48:00
|
MXP-MR-2_5G.config.trunk.AlsMode
|
Disabled
|
Disabled, Auto Restart, Manual Restart, Manual Restart for Test
|
MXP-MR-2_5G.config.trunk.AlsRecoveryPulseDuration
|
4.0 (seconds)
|
•2.0, 2.1, 2.2 .. 100.0 when AlsMode is Disabled, Auto Restart, Manual Restart
•80.0, 80.1, 80.2 .. 100.0 when AlsMode is Manual Restart for Test
|
MXP-MR-2_5G.config.trunk.AlsRecoveryPulseInterval
|
100 (seconds)
|
60-300
|
MXP-MR-2_5G.config.trunk.SDBER
|
1.00E-07
|
1E-5, 1E-6, 1E-7, 1E-8, 1E-9
|
MXP-MR-2_5G.config.trunk.SendDoNotUse
|
FALSE
|
TRUE, FALSE
|
MXP-MR-2_5G.config.trunk.SFBER
|
1.00E-04
|
1E-3, 1E-4, 1E-5
|
MXP-MR-2_5G.config.trunk.SyncMsgIn
|
TRUE
|
FALSE, TRUE
|
MXP-MR-2_5G.opticalthresholds.client.alarm.HighLaserBias
|
90.0 (%)
|
0.0, 0.1, 0.2 .. 100.0
|
MXP-MR-2_5G.opticalthresholds.client.alarm.HighRxPower
|
3.0 (dBm)
|
LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0
|
MXP-MR-2_5G.opticalthresholds.client.alarm.HighTxPower
|
3.0 (dBm)
|
LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0
|
MXP-MR-2_5G.opticalthresholds.client.alarm.LowRxPower
|
-21.0 (dBm)
|
-40.0, -39.9, -39.8 .. HighRxPower
|
MXP-MR-2_5G.opticalthresholds.client.alarm.LowTxPower
|
-8.0 (dBm)
|
-40.0, -39.9, -39.8 .. HighTxPower
|
MXP-MR-2_5G.opticalthresholds.client.warning.15min.HighLaserBias
|
81.0 (%)
|
0.0, 0.1, 0.2 .. 100.0
|
MXP-MR-2_5G.opticalthresholds.client.warning.15min.HighRxPower
|
2.0 (dBm)
|
LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0
|
MXP-MR-2_5G.opticalthresholds.client.warning.15min.HighTxPower
|
2.0 (dBm)
|
LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0
|
MXP-MR-2_5G.opticalthresholds.client.warning.15min.LowRxPower
|
-20.0 (dBm)
|
-40.0, -39.9, -39.8 .. HighRxPower
|
MXP-MR-2_5G.opticalthresholds.client.warning.15min.LowTxPower
|
-7.0 (dBm)
|
-40.0, -39.9, -39.8 .. HighTxPower
|
MXP-MR-2_5G.opticalthresholds.client.warning.1day.HighLaserBias
|
85.5 (%)
|
0.0, 0.1, 0.2 .. 100.0
|
MXP-MR-2_5G.opticalthresholds.client.warning.1day.HighRxPower
|
2.5 (dBm)
|
LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0
|
MXP-MR-2_5G.opticalthresholds.client.warning.1day.HighTxPower
|
2.5 (dBm)
|
LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0
|
MXP-MR-2_5G.opticalthresholds.client.warning.1day.LowRxPower
|
-20.5 (dBm)
|
-40.0, -39.9, -39.8 .. HighRxPower
|
MXP-MR-2_5G.opticalthresholds.client.warning.1day.LowTxPower
|
-7.5 (dBm)
|
-40.0, -39.9, -39.8 .. HighTxPower
|
MXP-MR-2_5G.opticalthresholds.trunk.alarm.HighLaserBias
|
98.0 (%)
|
0.0, 0.1, 0.2 .. 100.0
|
MXP-MR-2_5G.opticalthresholds.trunk.alarm.HighRxPower
|
-8.0 (dBm)
|
LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0
|
MXP-MR-2_5G.opticalthresholds.trunk.alarm.HighTxPower
|
30.0 (dBm)
|
LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0
|
MXP-MR-2_5G.opticalthresholds.trunk.alarm.LowRxPower
|
-25.0 (dBm)
|
-40.0, -39.9, -39.8 .. HighRxPower
|
MXP-MR-2_5G.opticalthresholds.trunk.alarm.LowTxPower
|
-40.0 (dBm)
|
-40.0, -39.9, -39.8 .. HighTxPower
|
MXP-MR-2_5G.opticalthresholds.trunk.warning.15min.HighLaserBias
|
95.0 (%)
|
0.0, 0.1, 0.2 .. 100.0
|
MXP-MR-2_5G.opticalthresholds.trunk.warning.15min.HighRxPower
|
-7.5 (dBm)
|
LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0
|
MXP-MR-2_5G.opticalthresholds.trunk.warning.15min.HighTxPower
|
30.0 (dBm)
|
LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0
|
MXP-MR-2_5G.opticalthresholds.trunk.warning.15min.LowRxPower
|
-24.5 (dBm)
|
-40.0, -39.9, -39.8 .. HighRxPower
|
MXP-MR-2_5G.opticalthresholds.trunk.warning.15min.LowTxPower
|
-40.0 (dBm)
|
-40.0, -39.9, -39.8 .. HighTxPower
|
MXP-MR-2_5G.opticalthresholds.trunk.warning.1day.HighLaserBias
|
96.0 (%)
|
0.0, 0.1, 0.2 .. 100.0
|
MXP-MR-2_5G.opticalthresholds.trunk.warning.1day.HighRxPower
|
-7.3 (dBm)
|
LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0
|
MXP-MR-2_5G.opticalthresholds.trunk.warning.1day.HighTxPower
|
30.0 (dBm)
|
LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0
|
MXP-MR-2_5G.opticalthresholds.trunk.warning.1day.LowRxPower
|
-24.7 (dBm)
|
-40.0, -39.9, -39.8 .. HighRxPower
|
MXP-MR-2_5G.opticalthresholds.trunk.warning.1day.LowTxPower
|
-40.0 (dBm)
|
-40.0, -39.9, -39.8 .. HighTxPower
|
MXP-MR-2_5G.pmthresholds.trunk.line.farend.15min.CV
|
21260 (B2 count)
|
0-2212200
|
MXP-MR-2_5G.pmthresholds.trunk.line.farend.15min.ES
|
87 (seconds)
|
0-900
|
MXP-MR-2_5G.pmthresholds.trunk.line.farend.15min.FC
|
10 (count)
|
0-72
|
MXP-MR-2_5G.pmthresholds.trunk.line.farend.15min.SES
|
1 (seconds)
|
0-900
|
MXP-MR-2_5G.pmthresholds.trunk.line.farend.15min.UAS
|
3 (seconds)
|
0-900
|
MXP-MR-2_5G.pmthresholds.trunk.line.farend.1day.CV
|
212600 (B2 count)
|
0-212371200
|
MXP-MR-2_5G.pmthresholds.trunk.line.farend.1day.ES
|
864 (seconds)
|
0-86400
|
MXP-MR-2_5G.pmthresholds.trunk.line.farend.1day.FC
|
40 (count)
|
0-6912
|
MXP-MR-2_5G.pmthresholds.trunk.line.farend.1day.SES
|
4 (seconds)
|
0-86400
|
MXP-MR-2_5G.pmthresholds.trunk.line.farend.1day.UAS
|
10 (seconds)
|
0-86400
|
MXP-MR-2_5G.pmthresholds.trunk.line.nearend.15min.CV
|
21260 (B2 count)
|
0-2212200
|
MXP-MR-2_5G.pmthresholds.trunk.line.nearend.15min.ES
|
87 (seconds)
|
0-900
|
MXP-MR-2_5G.pmthresholds.trunk.line.nearend.15min.FC
|
10 (count)
|
0-72
|
MXP-MR-2_5G.pmthresholds.trunk.line.nearend.15min.SES
|
1 (seconds)
|
0-900
|
MXP-MR-2_5G.pmthresholds.trunk.line.nearend.15min.UAS
|
3 (seconds)
|
0-900
|
MXP-MR-2_5G.pmthresholds.trunk.line.nearend.1day.CV
|
212600 (B2 count)
|
0-212371200
|
MXP-MR-2_5G.pmthresholds.trunk.line.nearend.1day.ES
|
864 (seconds)
|
0-86400
|
MXP-MR-2_5G.pmthresholds.trunk.line.nearend.1day.FC
|
40 (count)
|
0-6912
|
MXP-MR-2_5G.pmthresholds.trunk.line.nearend.1day.SES
|
4 (seconds)
|
0-86400
|
MXP-MR-2_5G.pmthresholds.trunk.line.nearend.1day.UAS
|
10 (seconds)
|
0-86400
|
MXP-MR-2_5G.pmthresholds.trunk.section.nearend.15min.CV
|
10000 (B1 count)
|
0-2151900
|
MXP-MR-2_5G.pmthresholds.trunk.section.nearend.15min.ES
|
500 (seconds)
|
0-900
|
MXP-MR-2_5G.pmthresholds.trunk.section.nearend.15min.SEFS
|
500 (seconds)
|
0-900
|
MXP-MR-2_5G.pmthresholds.trunk.section.nearend.15min.SES
|
500 (seconds)
|
0-900
|
MXP-MR-2_5G.pmthresholds.trunk.section.nearend.1day.CV
|
100000 (B1 count)
|
0-206582400
|
MXP-MR-2_5G.pmthresholds.trunk.section.nearend.1day.ES
|
5000 (seconds)
|
0-86400
|
MXP-MR-2_5G.pmthresholds.trunk.section.nearend.1day.SEFS
|
5000 (seconds)
|
0-86400
|
MXP-MR-2_5G.pmthresholds.trunk.section.nearend.1day.SES
|
5000 (seconds)
|
0-86400
|
D.2.1.4 MXPP_MR_2.5G Card Default Settings
Table D-4 lists the MXPP_MR_2.5G card default settings.
Table D-4 MXPP_MR_2.5G Card Default Settings (ANSI)
Default Name
|
Default Value
|
Default Domain
|
MXPP-MR-2_5G.config.client.AlsMode
|
Disabled
|
Disabled, Manual Restart, Manual Restart for Test
|
MXPP-MR-2_5G.config.client.AlsRecoveryPulseDuration
|
4.0 (seconds)
|
•2.0, 2.1, 2.2 .. 100.0 when AlsMode is Disabled, Auto Restart, Manual Restart
•80.0, 80.1, 80.2 .. 100.0 when AlsMode is Manual Restart for Test
|
MXPP-MR-2_5G.config.client.AlsRecoveryPulseInterval
|
100 (seconds)
|
60-300
|
MXPP-MR-2_5G.config.client.ppmPortAssignment
|
UNASSIGNED
|
UNASSIGNED, ONE_GE, FC1G ISL, FC2G ISL, FICON1G ISL, FICON2G ISL
|
MXPP-MR-2_5G.config.client.ppmSlotAssignment
|
UNASSIGNED
|
UNASSIGNED, PPM (1 Port)
|
MXPP-MR-2_5G.config.fc.distanceExtension.AutoadjustGFPBufferThreshold
|
TRUE
|
TRUE, FALSE
|
MXPP-MR-2_5G.config.fc.distanceExtension.AutoDetect
|
TRUE
|
TRUE, FALSE
|
MXPP-MR-2_5G.config.fc.distanceExtension.Enabled
|
TRUE
|
TRUE, FALSE
|
MXPP-MR-2_5G.config.fc.distanceExtension.NumCredits
|
32
|
2-256
|
MXPP-MR-2_5G.config.fc.distanceExtension.NumGFPBuffers
|
16
|
16, 32, 48 .. 1200
|
MXPP-MR-2_5G.config.fc.enhancedFibreChannelFicon.MaxFrameSize
|
2148
|
2148, 2152, 2156, 2160, 2164, 2168, 2172
|
MXPP-MR-2_5G.config.trunk.AINSSoakTime
|
08:00 (hours:mins)
|
00:00, 00:15, 00:30 .. 48:00
|
MXPP-MR-2_5G.config.trunk.AlsMode
|
Disabled
|
Disabled, Auto Restart, Manual Restart, Manual Restart for Test
|
MXPP-MR-2_5G.config.trunk.AlsRecoveryPulseDuration
|
4.0 (seconds)
|
•2.0, 2.1, 2.2 .. 100.0 when AlsMode is Disabled, Auto Restart, Manual Restart
•80.0, 80.1, 80.2 .. 100.0 when AlsMode is Manual Restart for Test
|
MXPP-MR-2_5G.config.trunk.AlsRecoveryPulseInterval
|
100 (seconds)
|
60-300
|
MXPP-MR-2_5G.config.trunk.SDBER
|
1.00E-07
|
1E-5, 1E-6, 1E-7, 1E-8, 1E-9
|
MXPP-MR-2_5G.config.trunk.SFBER
|
1.00E-04
|
1E-3, 1E-4, 1E-5
|
MXPP-MR-2_5G.opticalthresholds.client.alarm.HighLaserBias
|
90.0 (%)
|
0.0, 0.1, 0.2 .. 100.0
|
MXPP-MR-2_5G.opticalthresholds.client.alarm.HighRxPower
|
3.0 (dBm)
|
LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0
|
MXPP-MR-2_5G.opticalthresholds.client.alarm.HighTxPower
|
3.0 (dBm)
|
LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0
|
MXPP-MR-2_5G.opticalthresholds.client.alarm.LowRxPower
|
-21.0 (dBm)
|
-40.0, -39.9, -39.8 .. HighRxPower
|
MXPP-MR-2_5G.opticalthresholds.client.alarm.LowTxPower
|
-8.0 (dBm)
|
-40.0, -39.9, -39.8 .. HighTxPower
|
MXPP-MR-2_5G.opticalthresholds.client.warning.15min.HighLaserBias
|
81.0 (%)
|
0.0, 0.1, 0.2 .. 100.0
|
MXPP-MR-2_5G.opticalthresholds.client.warning.15min.HighRxPower
|
2.0 (dBm)
|
LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0
|
MXPP-MR-2_5G.opticalthresholds.client.warning.15min.HighTxPower
|
2.0 (dBm)
|
LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0
|
MXPP-MR-2_5G.opticalthresholds.client.warning.15min.LowRxPower
|
-20.0 (dBm)
|
-40.0, -39.9, -39.8 .. HighRxPower
|
MXPP-MR-2_5G.opticalthresholds.client.warning.15min.LowTxPower
|
-7.0 (dBm)
|
-40.0, -39.9, -39.8 .. HighTxPower
|
MXPP-MR-2_5G.opticalthresholds.client.warning.1day.HighLaserBias
|
85.5 (%)
|
0.0, 0.1, 0.2 .. 100.0
|
MXPP-MR-2_5G.opticalthresholds.client.warning.1day.HighRxPower
|
2.5 (dBm)
|
LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0
|
MXPP-MR-2_5G.opticalthresholds.client.warning.1day.HighTxPower
|
2.5 (dBm)
|
LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0
|
MXPP-MR-2_5G.opticalthresholds.client.warning.1day.LowRxPower
|
-20.5 (dBm)
|
-40.0, -39.9, -39.8 .. HighRxPower
|
MXPP-MR-2_5G.opticalthresholds.client.warning.1day.LowTxPower
|
-7.5 (dBm)
|
-40.0, -39.9, -39.8 .. HighTxPower
|
MXPP-MR-2_5G.opticalthresholds.trunk.alarm.HighLaserBias
|
98.0 (%)
|
0.0, 0.1, 0.2 .. 100.0
|
MXPP-MR-2_5G.opticalthresholds.trunk.alarm.HighRxPower
|
-8.0 (dBm)
|
LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0
|
MXPP-MR-2_5G.opticalthresholds.trunk.alarm.HighTxPower
|
30.0 (dBm)
|
LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0
|
MXPP-MR-2_5G.opticalthresholds.trunk.alarm.LowRxPower
|
-25.0 (dBm)
|
-40.0, -39.9, -39.8 .. HighRxPower
|
MXPP-MR-2_5G.opticalthresholds.trunk.alarm.LowTxPower
|
-40.0 (dBm)
|
-40.0, -39.9, -39.8 .. HighTxPower
|
MXPP-MR-2_5G.opticalthresholds.trunk.warning.15min.HighLaserBias
|
95.0 (%)
|
0.0, 0.1, 0.2 .. 100.0
|
MXPP-MR-2_5G.opticalthresholds.trunk.warning.15min.HighRxPower
|
-7.5 (dBm)
|
LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0
|
MXPP-MR-2_5G.opticalthresholds.trunk.warning.15min.HighTxPower
|
30.0 (dBm)
|
LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0
|
MXPP-MR-2_5G.opticalthresholds.trunk.warning.15min.LowRxPower
|
-24.5 (dBm)
|
-40.0, -39.9, -39.8 .. HighRxPower
|
MXPP-MR-2_5G.opticalthresholds.trunk.warning.15min.LowTxPower
|
-40.0 (dBm)
|
-40.0, -39.9, -39.8 .. HighTxPower
|
MXPP-MR-2_5G.opticalthresholds.trunk.warning.1day.HighLaserBias
|
96.0 (%)
|
0.0, 0.1, 0.2 .. 100.0
|
MXPP-MR-2_5G.opticalthresholds.trunk.warning.1day.HighRxPower
|
-7.3 (dBm)
|
LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0
|
MXPP-MR-2_5G.opticalthresholds.trunk.warning.1day.HighTxPower
|
30.0 (dBm)
|
LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0
|
MXPP-MR-2_5G.opticalthresholds.trunk.warning.1day.LowRxPower
|
-24.7 (dBm)
|
-40.0, -39.9, -39.8 .. HighRxPower
|
MXPP-MR-2_5G.opticalthresholds.trunk.warning.1day.LowTxPower
|
-40.0 (dBm)
|
-40.0, -39.9, -39.8 .. HighTxPower
|
MXPP-MR-2_5G.pmthresholds.trunk.line.farend.15min.CV
|
21260 (B2 count)
|
0-2212200
|
MXPP-MR-2_5G.pmthresholds.trunk.line.farend.15min.ES
|
87 (seconds)
|
0-900
|
MXPP-MR-2_5G.pmthresholds.trunk.line.farend.15min.FC
|
10 (count)
|
0-72
|
MXPP-MR-2_5G.pmthresholds.trunk.line.farend.15min.SES
|
1 (seconds)
|
0-900
|
MXPP-MR-2_5G.pmthresholds.trunk.line.farend.15min.UAS
|
3 (seconds)
|
0-900
|
MXPP-MR-2_5G.pmthresholds.trunk.line.farend.1day.CV
|
212600 (B2 count)
|
0-212371200
|
MXPP-MR-2_5G.pmthresholds.trunk.line.farend.1day.ES
|
864 (seconds)
|
0-86400
|
MXPP-MR-2_5G.pmthresholds.trunk.line.farend.1day.FC
|
40 (count)
|
0-6912
|
MXPP-MR-2_5G.pmthresholds.trunk.line.farend.1day.SES
|
4 (seconds)
|
0-86400
|
MXPP-MR-2_5G.pmthresholds.trunk.line.farend.1day.UAS
|
10 (seconds)
|
0-86400
|
MXPP-MR-2_5G.pmthresholds.trunk.line.nearend.15min.CV
|
21260 (B2 count)
|
0-2212200
|
MXPP-MR-2_5G.pmthresholds.trunk.line.nearend.15min.ES
|
87 (seconds)
|
0-900
|
MXPP-MR-2_5G.pmthresholds.trunk.line.nearend.15min.FC
|
10 (count)
|
0-72
|
MXPP-MR-2_5G.pmthresholds.trunk.line.nearend.15min.SES
|
1 (seconds)
|
0-900
|
MXPP-MR-2_5G.pmthresholds.trunk.line.nearend.15min.UAS
|
3 (seconds)
|
0-900
|
MXPP-MR-2_5G.pmthresholds.trunk.line.nearend.1day.CV
|
212600 (B2 count)
|
0-212371200
|
MXPP-MR-2_5G.pmthresholds.trunk.line.nearend.1day.ES
|
864 (seconds)
|
0-86400
|
MXPP-MR-2_5G.pmthresholds.trunk.line.nearend.1day.FC
|
40 (count)
|
0-6912
|
MXPP-MR-2_5G.pmthresholds.trunk.line.nearend.1day.SES
|
4 (seconds)
|
0-86400
|
MXPP-MR-2_5G.pmthresholds.trunk.line.nearend.1day.UAS
|
10 (seconds)
|
0-86400
|
MXPP-MR-2_5G.pmthresholds.trunk.section.nearend.15min.CV
|
10000 (B1 count)
|
0-2151900
|
MXPP-MR-2_5G.pmthresholds.trunk.section.nearend.15min.ES
|
500 (seconds)
|
0-900
|
MXPP-MR-2_5G.pmthresholds.trunk.section.nearend.15min.SEFS
|
500 (seconds)
|
0-900
|
MXPP-MR-2_5G.pmthresholds.trunk.section.nearend.15min.SES
|
500 (seconds)
|
0-900
|
MXPP-MR-2_5G.pmthresholds.trunk.section.nearend.1day.CV
|
100000 (B1 count)
|
0-206582400
|
MXPP-MR-2_5G.pmthresholds.trunk.section.nearend.1day.ES
|
5000 (seconds)
|
0-86400
|
MXPP-MR-2_5G.pmthresholds.trunk.section.nearend.1day.SEFS
|
5000 (seconds)
|
0-86400
|
MXPP-MR-2_5G.pmthresholds.trunk.section.nearend.1day.SES
|
5000 (seconds)
|
0-86400
|
D.2.1.5 TXP_MR_10E Card Default Settings
Table D-5 lists the TXP_MR_10E card default settings.
Table D-5 TXP_MR_10E Card Default Settings (ANSI)
Default Name
|
Default Value
|
Default Domain
|
TXP-MR-10E.config.client.AINSSoakTime
|
08:00 (hours:mins)
|
00:00, 00:15, 00:30 .. 48:00
|
TXP-MR-10E.config.client.AisSquelchMode
|
Squelch
|
Ais, Squelch
|
TXP-MR-10E.config.client.AlsMode
|
Disabled
|
Disabled, Auto Restart, Manual Restart, Manual Restart for Test
|
TXP-MR-10E.config.client.AlsRecoveryPulseDuration
|
2.0 (seconds)
|
•2.0, 2.1, 2.2 .. 100.0 when AlsMode is Disabled, Auto Restart, Manual Restart
•80.0, 80.1, 80.2 .. 100.0 when AlsMode is Manual Restart for Test
|
TXP-MR-10E.config.client.AlsRecoveryPulseInterval
|
100 (seconds)
|
100-2000
|
TXP-MR-10E.config.client.ppmPortAssignment
|
UNASSIGNED
|
UNASSIGNED, SONET (including 10G Ethernet WAN Phy), 10G Ethernet LAN Phy, 10G Fiber Channel
|
TXP-MR-10E.config.client.ppmSlotAssignment
|
UNASSIGNED
|
UNASSIGNED, PPM (1 Port)
|
TXP-MR-10E.config.client.SDBER
|
1.00E-07
|
1E-5, 1E-6, 1E-7, 1E-8, 1E-9
|
TXP-MR-10E.config.client.SendDoNotUse
|
FALSE
|
TRUE, FALSE
|
TXP-MR-10E.config.client.SFBER
|
1.00E-04
|
1E-3, 1E-4, 1E-5
|
TXP-MR-10E.config.client.SyncMsgIn
|
TRUE
|
FALSE, TRUE
|
TXP-MR-10E.config.client.TerminationMode
|
Transparent
|
•Transparent, Line when ppmPortAssignment is UNASSIGNED, SONET (including 10G Ethernet WAN Phy)
•Transparent when ppmPortAssignment is 10G Ethernet LAN Phy, 10G Fiber Channel
|
TXP-MR-10E.config.trunk.AINSSoakTime
|
08:00 (hours:mins)
|
00:00, 00:15, 00:30 .. 48:00
|
TXP-MR-10E.config.trunk.AlsMode
|
Disabled
|
Disabled, Auto Restart, Manual Restart, Manual Restart for Test
|
TXP-MR-10E.config.trunk.AlsRecoveryPulseDuration
|
100.0 (seconds)
|
•6.0, 6.1, 6.2 .. 200.0 when AlsMode is Disabled, Auto Restart, Manual Restart
•80.0, 80.1, 80.2 .. 100.0 when AlsMode is Manual Restart for Test
|
TXP-MR-10E.config.trunk.AlsRecoveryPulseInterval
|
300 (seconds)
|
200-2000
|
TXP-MR-10E.config.trunk.SDBER
|
1.00E-07
|
1E-5, 1E-6, 1E-7, 1E-8, 1E-9
|
TXP-MR-10E.config.trunk.SFBER
|
1.00E-04
|
1E-3, 1E-4, 1E-5
|
TXP-MR-10E.opticalthresholds.client.alarm.HighLaserBias
|
90.0 (%)
|
0.0, 0.1, 0.2 .. 100.0
|
TXP-MR-10E.opticalthresholds.client.alarm.HighRxPower
|
2.0 (dBm)
|
-17.0, -16.9, -16.8 .. 30.0
|
TXP-MR-10E.opticalthresholds.client.alarm.HighTxPower
|
2.0 (dBm)
|
-9.0, -8.9, -8.8 .. 30.0
|
TXP-MR-10E.opticalthresholds.client.alarm.LowRxPower
|
-17.0 (dBm)
|
-40.0, -39.9, -39.8 .. 2.0
|
TXP-MR-10E.opticalthresholds.client.alarm.LowTxPower
|
-9.0 (dBm)
|
-40.0, -39.9, -39.8 .. 2.0
|
TXP-MR-10E.opticalthresholds.client.warning.15min.HighLaserBias
|
81.0 (%)
|
0.0, 0.1, 0.2 .. 100.0
|
TXP-MR-10E.opticalthresholds.client.warning.15min.HighRxPower
|
1.0 (dBm)
|
-16.0, -15.9, -15.8 .. 30.0
|
TXP-MR-10E.opticalthresholds.client.warning.15min.HighTxPower
|
1.0 (dBm)
|
-8.0, -7.9, -7.8 .. 30.0
|
TXP-MR-10E.opticalthresholds.client.warning.15min.LowRxPower
|
-16.0 (dBm)
|
-40.0, -39.9, -39.8 .. 1.0
|
TXP-MR-10E.opticalthresholds.client.warning.15min.LowTxPower
|
-8.0 (dBm)
|
-40.0, -39.9, -39.8 .. 1.0
|
TXP-MR-10E.opticalthresholds.client.warning.1day.HighLaserBias
|
85.5 (%)
|
0.0, 0.1, 0.2 .. 100.0
|
TXP-MR-10E.opticalthresholds.client.warning.1day.HighRxPower
|
1.5 (dBm)
|
-16.5, -16.4, -16.3 .. 30.0
|
TXP-MR-10E.opticalthresholds.client.warning.1day.HighTxPower
|
1.5 (dBm)
|
-8.5, -8.4, -8.3 .. 30.0
|
TXP-MR-10E.opticalthresholds.client.warning.1day.LowRxPower
|
-16.5 (dBm)
|
-40.0, -39.9, -39.8 .. 1.5
|
TXP-MR-10E.opticalthresholds.client.warning.1day.LowTxPower
|
-8.5 (dBm)
|
-40.0, -39.9, -39.8 .. 1.5
|
TXP-MR-10E.opticalthresholds.trunk.alarm.HighLaserBias
|
98.0 (%)
|
0.0, 0.1, 0.2 .. 100.0
|
TXP-MR-10E.opticalthresholds.trunk.alarm.HighRxPower
|
-8.0 (dBm)
|
-25.0, -24.9, -24.8 .. 30.0
|
TXP-MR-10E.opticalthresholds.trunk.alarm.HighTxPower
|
8.0 (dBm)
|
1.0, 1.1, 1.2 .. 30.0
|
TXP-MR-10E.opticalthresholds.trunk.alarm.LowRxPower
|
-25.0 (dBm)
|
-40.0, -39.9, -39.8 .. -8.0
|
TXP-MR-10E.opticalthresholds.trunk.alarm.LowTxPower
|
1.0 (dBm)
|
-40.0, -39.9, -39.8 .. 8.0
|
TXP-MR-10E.opticalthresholds.trunk.warning.15min.HighLaserBias
|
95.0 (%)
|
0.0, 0.1, 0.2 .. 100.0
|
TXP-MR-10E.opticalthresholds.trunk.warning.15min.HighRxPower
|
-7.5 (dBm)
|
-24.5, -24.4, -24.3 .. 30.0
|
TXP-MR-10E.opticalthresholds.trunk.warning.15min.HighTxPower
|
7.0 (dBm)
|
2.0, 2.1, 2.2 .. 30.0
|
TXP-MR-10E.opticalthresholds.trunk.warning.15min.LowRxPower
|
-24.5 (dBm)
|
-40.0, -39.9, -39.8 .. -7.5
|
TXP-MR-10E.opticalthresholds.trunk.warning.15min.LowTxPower
|
2.0 (dBm)
|
-40.0, -39.9, -39.8 .. 7.0
|
TXP-MR-10E.opticalthresholds.trunk.warning.1day.HighLaserBias
|
96.0 (%)
|
0.0, 0.1, 0.2 .. 100.0
|
TXP-MR-10E.opticalthresholds.trunk.warning.1day.HighRxPower
|
-7.3 (dBm)
|
-24.7, -24.6, -24.5 .. 30.0
|
TXP-MR-10E.opticalthresholds.trunk.warning.1day.HighTxPower
|
7.0 (dBm)
|
2.0, 2.1, 2.2 .. 30.0
|
TXP-MR-10E.opticalthresholds.trunk.warning.1day.LowRxPower
|
-24.7 (dBm)
|
-40.0, -39.9, -39.8 .. -7.3
|
TXP-MR-10E.opticalthresholds.trunk.warning.1day.LowTxPower
|
2.0 (dBm)
|
-40.0, -39.9, -39.8 .. 7.0
|
TXP-MR-10E.otn.fecthresholds.enhanced.15min.BitErrorsCorrected
|
903330 (count)
|
0-9033621811200
|
TXP-MR-10E.otn.fecthresholds.enhanced.15min.UncorrectableWords
|
5 (count)
|
0-4724697600
|
TXP-MR-10E.otn.fecthresholds.enhanced.1day.BitErrorsCorrected
|
86719680 (count)
|
0-867227693875200
|
TXP-MR-10E.otn.fecthresholds.enhanced.1day.UncorrectableWords
|
480 (count)
|
0-453570969600
|
TXP-MR-10E.otn.fecthresholds.standard.15min.BitErrorsCorrected
|
903330 (count)
|
0-9033621811200
|
TXP-MR-10E.otn.fecthresholds.standard.15min.UncorrectableWords
|
5 (count)
|
0-4724697600
|
TXP-MR-10E.otn.fecthresholds.standard.1day.BitErrorsCorrected
|
86719680 (count)
|
0-867227693875200
|
TXP-MR-10E.otn.fecthresholds.standard.1day.UncorrectableWords
|
480 (count)
|
0-453570969600
|
TXP-MR-10E.otn.g709thresholds.pm.farend.15min.BBE
|
85040 (count)
|
0-8850600
|
TXP-MR-10E.otn.g709thresholds.pm.farend.15min.ES
|
87 (seconds)
|
0-900
|
TXP-MR-10E.otn.g709thresholds.pm.farend.15min.FC
|
10 (count)
|
0-72
|
TXP-MR-10E.otn.g709thresholds.pm.farend.15min.SES
|
1 (seconds)
|
0-900
|
TXP-MR-10E.otn.g709thresholds.pm.farend.15min.UAS
|
3 (seconds)
|
0-900
|
TXP-MR-10E.otn.g709thresholds.pm.farend.1day.BBE
|
850400 (count)
|
0-849657600
|
TXP-MR-10E.otn.g709thresholds.pm.farend.1day.ES
|
864 (seconds)
|
0-86400
|
TXP-MR-10E.otn.g709thresholds.pm.farend.1day.FC
|
40 (count)
|
0-6912
|
TXP-MR-10E.otn.g709thresholds.pm.farend.1day.SES
|
4 (seconds)
|
0-86400
|
TXP-MR-10E.otn.g709thresholds.pm.farend.1day.UAS
|
10 (seconds)
|
0-86400
|
TXP-MR-10E.otn.g709thresholds.pm.nearend.15min.BBE
|
85040 (count)
|
0-8850600
|
TXP-MR-10E.otn.g709thresholds.pm.nearend.15min.ES
|
87 (seconds)
|
0-900
|
TXP-MR-10E.otn.g709thresholds.pm.nearend.15min.FC
|
10 (count)
|
0-72
|
TXP-MR-10E.otn.g709thresholds.pm.nearend.15min.SES
|
1 (seconds)
|
0-900
|
TXP-MR-10E.otn.g709thresholds.pm.nearend.15min.UAS
|
3 (seconds)
|
0-900
|
TXP-MR-10E.otn.g709thresholds.pm.nearend.1day.BBE
|
850400 (count)
|
0-849657600
|
TXP-MR-10E.otn.g709thresholds.pm.nearend.1day.ES
|
864 (seconds)
|
0-86400
|
TXP-MR-10E.otn.g709thresholds.pm.nearend.1day.FC
|
40 (count)
|
0-6912
|
TXP-MR-10E.otn.g709thresholds.pm.nearend.1day.SES
|
4 (seconds)
|
0-86400
|
TXP-MR-10E.otn.g709thresholds.pm.nearend.1day.UAS
|
10 (seconds)
|
0-86400
|
TXP-MR-10E.otn.g709thresholds.sm.farend.15min.BBE
|
10000 (count)
|
0-8850600
|
TXP-MR-10E.otn.g709thresholds.sm.farend.15min.ES
|
500 (seconds)
|
0-900
|
TXP-MR-10E.otn.g709thresholds.sm.farend.15min.FC
|
10 (count)
|
0-72
|
TXP-MR-10E.otn.g709thresholds.sm.farend.15min.SES
|
500 (seconds)
|
0-900
|
TXP-MR-10E.otn.g709thresholds.sm.farend.15min.UAS
|
500 (seconds)
|
0-900
|
TXP-MR-10E.otn.g709thresholds.sm.farend.1day.BBE
|
100000 (count)
|
0-849657600
|
TXP-MR-10E.otn.g709thresholds.sm.farend.1day.ES
|
5000 (seconds)
|
0-86400
|
TXP-MR-10E.otn.g709thresholds.sm.farend.1day.FC
|
40 (count)
|
0-6912
|
TXP-MR-10E.otn.g709thresholds.sm.farend.1day.SES
|
5000 (seconds)
|
0-86400
|
TXP-MR-10E.otn.g709thresholds.sm.farend.1day.UAS
|
5000 (seconds)
|
0-86400
|
TXP-MR-10E.otn.g709thresholds.sm.nearend.15min.BBE
|
10000 (count)
|
0-8850600
|
TXP-MR-10E.otn.g709thresholds.sm.nearend.15min.ES
|
500 (seconds)
|
0-900
|
TXP-MR-10E.otn.g709thresholds.sm.nearend.15min.FC
|
10 (count)
|
0-72
|
TXP-MR-10E.otn.g709thresholds.sm.nearend.15min.SES
|
500 (seconds)
|
0-900
|
TXP-MR-10E.otn.g709thresholds.sm.nearend.15min.UAS
|
500 (seconds)
|
0-900
|
TXP-MR-10E.otn.g709thresholds.sm.nearend.1day.BBE
|
100000 (count)
|
0-849657600
|
TXP-MR-10E.otn.g709thresholds.sm.nearend.1day.ES
|
5000 (seconds)
|
0-86400
|
TXP-MR-10E.otn.g709thresholds.sm.nearend.1day.FC
|
40 (count)
|
0-6912
|
TXP-MR-10E.otn.g709thresholds.sm.nearend.1day.SES
|
5000 (seconds)
|
0-86400
|
TXP-MR-10E.otn.g709thresholds.sm.nearend.1day.UAS
|
5000 (seconds)
|
0-86400
|
TXP-MR-10E.otn.otnLines.AsynchSynchMapping
|
Synch Mapping
|
Asynch mapping, Synch Mapping
|
TXP-MR-10E.otn.otnLines.FEC
|
Standard
|
•Disable, Standard, Enhanced when G709OTN is Enable
•Disable when G709OTN is Disable
|
TXP-MR-10E.otn.otnLines.G709OTN
|
Enable
|
Disable, Enable
|
TXP-MR-10E.otn.otnLines.SDBER
|
1.00E-07
|
1E-5, 1E-6, 1E-7, 1E-8, 1E-9
|
TXP-MR-10E.pmthresholds.client.line.farend.15min.CV
|
85040 (B2 count)
|
0-8850600
|
TXP-MR-10E.pmthresholds.client.line.farend.15min.ES
|
87 (seconds)
|
0-900
|
TXP-MR-10E.pmthresholds.client.line.farend.15min.FC
|
10 (count)
|
0-72
|
TXP-MR-10E.pmthresholds.client.line.farend.15min.SES
|
1 (seconds)
|
0-900
|
TXP-MR-10E.pmthresholds.client.line.farend.15min.UAS
|
3 (seconds)
|
0-900
|
TXP-MR-10E.pmthresholds.client.line.farend.1day.CV
|
850400 (B2 count)
|
0-849657600
|
TXP-MR-10E.pmthresholds.client.line.farend.1day.ES
|
864 (seconds)
|
0-86400
|
TXP-MR-10E.pmthresholds.client.line.farend.1day.FC
|
40 (count)
|
0-6912
|
TXP-MR-10E.pmthresholds.client.line.farend.1day.SES
|
4 (seconds)
|
0-86400
|
TXP-MR-10E.pmthresholds.client.line.farend.1day.UAS
|
10 (seconds)
|
0-86400
|
TXP-MR-10E.pmthresholds.client.line.nearend.15min.CV
|
85040 (B2 count)
|
0-8850600
|
TXP-MR-10E.pmthresholds.client.line.nearend.15min.ES
|
87 (seconds)
|
0-900
|
TXP-MR-10E.pmthresholds.client.line.nearend.15min.FC
|
10 (count)
|
0-72
|
TXP-MR-10E.pmthresholds.client.line.nearend.15min.SES
|
1 (seconds)
|
0-900
|
TXP-MR-10E.pmthresholds.client.line.nearend.15min.UAS
|
3 (seconds)
|
0-900
|
TXP-MR-10E.pmthresholds.client.line.nearend.1day.CV
|
850400 (B2 count)
|
0-849657600
|
TXP-MR-10E.pmthresholds.client.line.nearend.1day.ES
|
864 (seconds)
|
0-86400
|
TXP-MR-10E.pmthresholds.client.line.nearend.1day.FC
|
40 (count)
|
0-6912
|
TXP-MR-10E.pmthresholds.client.line.nearend.1day.SES
|
4 (seconds)
|
0-86400
|
TXP-MR-10E.pmthresholds.client.line.nearend.1day.UAS
|
10 (seconds)
|
0-86400
|
TXP-MR-10E.pmthresholds.client.section.nearend.15min.CV
|
10000 (B1 count)
|
0-7967700
|
TXP-MR-10E.pmthresholds.client.section.nearend.15min.ES
|
500 (seconds)
|
0-900
|
TXP-MR-10E.pmthresholds.client.section.nearend.15min.SEFS
|
500 (seconds)
|
0-900
|
TXP-MR-10E.pmthresholds.client.section.nearend.15min.SES
|
500 (seconds)
|
0-900
|
TXP-MR-10E.pmthresholds.client.section.nearend.1day.CV
|
100000 (B1 count)
|
0-764899200
|
TXP-MR-10E.pmthresholds.client.section.nearend.1day.ES
|
5000 (seconds)
|
0-86400
|
TXP-MR-10E.pmthresholds.client.section.nearend.1day.SEFS
|
5000 (seconds)
|
0-86400
|
TXP-MR-10E.pmthresholds.client.section.nearend.1day.SES
|
5000 (seconds)
|
0-86400
|
TXP-MR-10E.pmthresholds.trunk.line.farend.15min.CV
|
85040 (B2 count)
|
0-8850600
|
TXP-MR-10E.pmthresholds.trunk.line.farend.15min.ES
|
87 (seconds)
|
0-900
|
TXP-MR-10E.pmthresholds.trunk.line.farend.15min.FC
|
10 (count)
|
0-72
|
TXP-MR-10E.pmthresholds.trunk.line.farend.15min.SES
|
1 (seconds)
|
0-900
|
TXP-MR-10E.pmthresholds.trunk.line.farend.15min.UAS
|
3 (seconds)
|
0-900
|
TXP-MR-10E.pmthresholds.trunk.line.farend.1day.CV
|
850400 (B2 count)
|
0-849657600
|
TXP-MR-10E.pmthresholds.trunk.line.farend.1day.ES
|
864 (seconds)
|
0-86400
|
TXP-MR-10E.pmthresholds.trunk.line.farend.1day.FC
|
40 (count)
|
0-6912
|
TXP-MR-10E.pmthresholds.trunk.line.farend.1day.SES
|
4 (seconds)
|
0-86400
|
TXP-MR-10E.pmthresholds.trunk.line.farend.1day.UAS
|
10 (seconds)
|
0-86400
|
TXP-MR-10E.pmthresholds.trunk.line.nearend.15min.CV
|
85040 (B2 count)
|
0-8850600
|
TXP-MR-10E.pmthresholds.trunk.line.nearend.15min.ES
|
87 (seconds)
|
0-900
|
TXP-MR-10E.pmthresholds.trunk.line.nearend.15min.FC
|
10 (count)
|
0-72
|
TXP-MR-10E.pmthresholds.trunk.line.nearend.15min.SES
|
1 (seconds)
|
0-900
|
TXP-MR-10E.pmthresholds.trunk.line.nearend.15min.UAS
|
3 (seconds)
|
0-900
|
TXP-MR-10E.pmthresholds.trunk.line.nearend.1day.CV
|
850400 (B2 count)
|
0-849657600
|
TXP-MR-10E.pmthresholds.trunk.line.nearend.1day.ES
|
864 (seconds)
|
0-86400
|
TXP-MR-10E.pmthresholds.trunk.line.nearend.1day.FC
|
40 (count)
|
0-6912
|
TXP-MR-10E.pmthresholds.trunk.line.nearend.1day.SES
|
4 (seconds)
|
0-86400
|
TXP-MR-10E.pmthresholds.trunk.line.nearend.1day.UAS
|
10 (seconds)
|
0-86400
|
TXP-MR-10E.pmthresholds.trunk.section.nearend.15min.CV
|
10000 (B1 count)
|
0-7967700
|
TXP-MR-10E.pmthresholds.trunk.section.nearend.15min.ES
|
500 (seconds)
|
0-900
|
TXP-MR-10E.pmthresholds.trunk.section.nearend.15min.SEFS
|
500 (seconds)
|
0-900
|
TXP-MR-10E.pmthresholds.trunk.section.nearend.15min.SES
|
500 (seconds)
|
0-900
|
TXP-MR-10E.pmthresholds.trunk.section.nearend.1day.CV
|
100000 (B1 count)
|
0-764899200
|
TXP-MR-10E.pmthresholds.trunk.section.nearend.1day.ES
|
5000 (seconds)
|
0-86400
|
TXP-MR-10E.pmthresholds.trunk.section.nearend.1day.SEFS
|
5000 (seconds)
|
0-86400
|
TXP-MR-10E.pmthresholds.trunk.section.nearend.1day.SES
|
5000 (seconds)
|
0-86400
|
D.2.1.6 TXP_MR_10G Card Default Settings
Table D-6 lists the TXP_MR_10G card default settings.
Table D-6 TXP_MR_10G Card Default Settings (ANSI)
Default Name
|
Default Value
|
Default Domain
|
TXP-MR-10G.config.client.AINSSoakTime
|
08:00 (hours:mins)
|
00:00, 00:15, 00:30 .. 48:00
|
TXP-MR-10G.config.client.AlsMode
|
Disabled
|
Disabled, Auto Restart, Manual Restart, Manual Restart for Test
|
TXP-MR-10G.config.client.AlsRecoveryPulseDuration
|
4.0 (seconds)
|
•2.0, 2.1, 2.2 .. 100.0 when AlsMode is Disabled, Auto Restart, Manual Restart
•80.0, 80.1, 80.2 .. 100.0 when AlsMode is Manual Restart for Test
|
TXP-MR-10G.config.client.AlsRecoveryPulseInterval
|
100 (seconds)
|
60-300
|
TXP-MR-10G.config.client.mrPortAssignment
|
UNASSIGNED
|
UNASSIGNED, SONET (including 10G Ethernet WAN Phy), 10G Ethernet LAN Phy
|
TXP-MR-10G.config.client.SDBER
|
1.00E-07
|
1E-5, 1E-6, 1E-7, 1E-8, 1E-9
|
TXP-MR-10G.config.client.SFBER
|
1.00E-04
|
1E-3, 1E-4, 1E-5
|
TXP-MR-10G.config.client.TerminationMode
|
Transparent
|
•Transparent, Line when mrPortAssignment is UNASSIGNED, SONET (including 10G Ethernet WAN Phy)
•Transparent when mrPortAssignment is 10G Ethernet LAN Phy
|
TXP-MR-10G.config.trunk.AINSSoakTime
|
08:00 (hours:mins)
|
00:00, 00:15, 00:30 .. 48:00
|
TXP-MR-10G.config.trunk.AlsMode
|
Disabled
|
Disabled, Auto Restart, Manual Restart, Manual Restart for Test
|
TXP-MR-10G.config.trunk.AlsRecoveryPulseDuration
|
4.0 (seconds)
|
•2.0, 2.1, 2.2 .. 100.0 when AlsMode is Disabled, Auto Restart, Manual Restart
•80.0, 80.1, 80.2 .. 100.0 when AlsMode is Manual Restart for Test
|
TXP-MR-10G.config.trunk.AlsRecoveryPulseInterval
|
100 (seconds)
|
60-300
|
TXP-MR-10G.config.trunk.SDBER
|
1.00E-07
|
1E-5, 1E-6, 1E-7, 1E-8, 1E-9
|
TXP-MR-10G.config.trunk.SFBER
|
1.00E-04
|
1E-3, 1E-4, 1E-5
|
TXP-MR-10G.opticalthresholds.client.alarm.HighLaserBias
|
90.0 (%)
|
0.0, 0.1, 0.2 .. 100.0
|
TXP-MR-10G.opticalthresholds.client.alarm.HighRxPower
|
2.0 (dBm)
|
LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0
|
TXP-MR-10G.opticalthresholds.client.alarm.HighTxPower
|
2.0 (dBm)
|
LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0
|
TXP-MR-10G.opticalthresholds.client.alarm.LowRxPower
|
-17.0 (dBm)
|
-40.0, -39.9, -39.8 .. HighRxPower
|
TXP-MR-10G.opticalthresholds.client.alarm.LowTxPower
|
-9.0 (dBm)
|
-40.0, -39.9, -39.8 .. HighTxPower
|
TXP-MR-10G.opticalthresholds.client.warning.15min.HighLaserBias
|
81.0 (%)
|
0.0, 0.1, 0.2 .. 100.0
|
TXP-MR-10G.opticalthresholds.client.warning.15min.HighRxPower
|
1.0 (dBm)
|
LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0
|
TXP-MR-10G.opticalthresholds.client.warning.15min.HighTxPower
|
1.0 (dBm)
|
LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0
|
TXP-MR-10G.opticalthresholds.client.warning.15min.LowRxPower
|
-16.0 (dBm)
|
-40.0, -39.9, -39.8 .. HighRxPower
|
TXP-MR-10G.opticalthresholds.client.warning.15min.LowTxPower
|
-8.0 (dBm)
|
-40.0, -39.9, -39.8 .. HighTxPower
|
TXP-MR-10G.opticalthresholds.client.warning.1day.HighLaserBias
|
85.5 (%)
|
0.0, 0.1, 0.2 .. 100.0
|
TXP-MR-10G.opticalthresholds.client.warning.1day.HighRxPower
|
1.5 (dBm)
|
LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0
|
TXP-MR-10G.opticalthresholds.client.warning.1day.HighTxPower
|
1.5 (dBm)
|
LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0
|
TXP-MR-10G.opticalthresholds.client.warning.1day.LowRxPower
|
-16.5 (dBm)
|
-40.0, -39.9, -39.8 .. HighRxPower
|
TXP-MR-10G.opticalthresholds.client.warning.1day.LowTxPower
|
-8.5 (dBm)
|
-40.0, -39.9, -39.8 .. HighTxPower
|
TXP-MR-10G.opticalthresholds.trunk.alarm.HighLaserBias
|
90.0 (%)
|
0.0, 0.1, 0.2 .. 100.0
|
TXP-MR-10G.opticalthresholds.trunk.alarm.HighRxPower
|
-8.0 (dBm)
|
LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0
|
TXP-MR-10G.opticalthresholds.trunk.alarm.HighTxPower
|
4.0 (dBm)
|
LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0
|
TXP-MR-10G.opticalthresholds.trunk.alarm.LowRxPower
|
-25.0 (dBm)
|
-40.0, -39.9, -39.8 .. HighRxPower
|
TXP-MR-10G.opticalthresholds.trunk.alarm.LowTxPower
|
2.0 (dBm)
|
-40.0, -39.9, -39.8 .. HighTxPower
|
TXP-MR-10G.opticalthresholds.trunk.warning.15min.HighLaserBias
|
81.0 (%)
|
0.0, 0.1, 0.2 .. 100.0
|
TXP-MR-10G.opticalthresholds.trunk.warning.15min.HighRxPower
|
-7.5 (dBm)
|
LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0
|
TXP-MR-10G.opticalthresholds.trunk.warning.15min.HighTxPower
|
3.5 (dBm)
|
LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0
|
TXP-MR-10G.opticalthresholds.trunk.warning.15min.LowRxPower
|
-24.5 (dBm)
|
-40.0, -39.9, -39.8 .. HighRxPower
|
TXP-MR-10G.opticalthresholds.trunk.warning.15min.LowTxPower
|
2.5 (dBm)
|
-40.0, -39.9, -39.8 .. HighTxPower
|
TXP-MR-10G.opticalthresholds.trunk.warning.1day.HighLaserBias
|
85.5 (%)
|
0.0, 0.1, 0.2 .. 100.0
|
TXP-MR-10G.opticalthresholds.trunk.warning.1day.HighRxPower
|
-7.3 (dBm)
|
LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0
|
TXP-MR-10G.opticalthresholds.trunk.warning.1day.HighTxPower
|
3.7 (dBm)
|
LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0
|
TXP-MR-10G.opticalthresholds.trunk.warning.1day.LowRxPower
|
-24.7 (dBm)
|
-40.0, -39.9, -39.8 .. HighRxPower
|
TXP-MR-10G.opticalthresholds.trunk.warning.1day.LowTxPower
|
2.3 (dBm)
|
-40.0, -39.9, -39.8 .. HighTxPower
|
TXP-MR-10G.otn.fecthresholds.standard.15min.BitErrorsCorrected
|
903330 (count)
|
0-9033621811200
|
TXP-MR-10G.otn.fecthresholds.standard.15min.UncorrectableWords
|
5 (count)
|
0-4724697600
|
TXP-MR-10G.otn.fecthresholds.standard.1day.BitErrorsCorrected
|
86719680 (count)
|
0-867227693875200
|
TXP-MR-10G.otn.fecthresholds.standard.1day.UncorrectableWords
|
480 (count)
|
0-453570969600
|
TXP-MR-10G.otn.g709thresholds.pm.farend.15min.BBE
|
85040 (count)
|
0-8850600
|
TXP-MR-10G.otn.g709thresholds.pm.farend.15min.ES
|
87 (seconds)
|
0-900
|
TXP-MR-10G.otn.g709thresholds.pm.farend.15min.FC
|
10 (count)
|
0-72
|
TXP-MR-10G.otn.g709thresholds.pm.farend.15min.SES
|
1 (seconds)
|
0-900
|
TXP-MR-10G.otn.g709thresholds.pm.farend.15min.UAS
|
3 (seconds)
|
0-900
|
TXP-MR-10G.otn.g709thresholds.pm.farend.1day.BBE
|
850400 (count)
|
0-849657600
|
TXP-MR-10G.otn.g709thresholds.pm.farend.1day.ES
|
864 (seconds)
|
0-86400
|
TXP-MR-10G.otn.g709thresholds.pm.farend.1day.FC
|
40 (count)
|
0-6912
|
TXP-MR-10G.otn.g709thresholds.pm.farend.1day.SES
|
4 (seconds)
|
0-86400
|
TXP-MR-10G.otn.g709thresholds.pm.farend.1day.UAS
|
10 (seconds)
|
0-86400
|
TXP-MR-10G.otn.g709thresholds.pm.nearend.15min.BBE
|
85040 (count)
|
0-8850600
|
TXP-MR-10G.otn.g709thresholds.pm.nearend.15min.ES
|
87 (seconds)
|
0-900
|
TXP-MR-10G.otn.g709thresholds.pm.nearend.15min.FC
|
10 (count)
|
0-72
|
TXP-MR-10G.otn.g709thresholds.pm.nearend.15min.SES
|
1 (seconds)
|
0-900
|
TXP-MR-10G.otn.g709thresholds.pm.nearend.15min.UAS
|
3 (seconds)
|
0-900
|
TXP-MR-10G.otn.g709thresholds.pm.nearend.1day.BBE
|
850400 (count)
|
0-849657600
|
TXP-MR-10G.otn.g709thresholds.pm.nearend.1day.ES
|
864 (seconds)
|
0-86400
|
TXP-MR-10G.otn.g709thresholds.pm.nearend.1day.FC
|
40 (count)
|
0-6912
|
TXP-MR-10G.otn.g709thresholds.pm.nearend.1day.SES
|
4 (seconds)
|
0-86400
|
TXP-MR-10G.otn.g709thresholds.pm.nearend.1day.UAS
|
10 (seconds)
|
0-86400
|
TXP-MR-10G.otn.g709thresholds.sm.farend.15min.BBE
|
10000 (count)
|
0-8850600
|
TXP-MR-10G.otn.g709thresholds.sm.farend.15min.ES
|
500 (seconds)
|
0-900
|
TXP-MR-10G.otn.g709thresholds.sm.farend.15min.FC
|
10 (count)
|
0-72
|
TXP-MR-10G.otn.g709thresholds.sm.farend.15min.SES
|
500 (seconds)
|
0-900
|
TXP-MR-10G.otn.g709thresholds.sm.farend.15min.UAS
|
500 (seconds)
|
0-900
|
TXP-MR-10G.otn.g709thresholds.sm.farend.1day.BBE
|
100000 (count)
|
0-849657600
|
TXP-MR-10G.otn.g709thresholds.sm.farend.1day.ES
|
5000 (seconds)
|
0-86400
|
TXP-MR-10G.otn.g709thresholds.sm.farend.1day.FC
|
40 (count)
|
0-6912
|
TXP-MR-10G.otn.g709thresholds.sm.farend.1day.SES
|
5000 (seconds)
|
0-86400
|
TXP-MR-10G.otn.g709thresholds.sm.farend.1day.UAS
|
5000 (seconds)
|
0-86400
|
TXP-MR-10G.otn.g709thresholds.sm.nearend.15min.BBE
|
10000 (count)
|
0-8850600
|
TXP-MR-10G.otn.g709thresholds.sm.nearend.15min.ES
|
500 (seconds)
|
0-900
|
TXP-MR-10G.otn.g709thresholds.sm.nearend.15min.FC
|
10 (count)
|
0-72
|
TXP-MR-10G.otn.g709thresholds.sm.nearend.15min.SES
|
500 (seconds)
|
0-900
|
TXP-MR-10G.otn.g709thresholds.sm.nearend.15min.UAS
|
500 (seconds)
|
0-900
|
TXP-MR-10G.otn.g709thresholds.sm.nearend.1day.BBE
|
100000 (count)
|
0-849657600
|
TXP-MR-10G.otn.g709thresholds.sm.nearend.1day.ES
|
5000 (seconds)
|
0-86400
|
TXP-MR-10G.otn.g709thresholds.sm.nearend.1day.FC
|
40 (count)
|
0-6912
|
TXP-MR-10G.otn.g709thresholds.sm.nearend.1day.SES
|
5000 (seconds)
|
0-86400
|
TXP-MR-10G.otn.g709thresholds.sm.nearend.1day.UAS
|
5000 (seconds)
|
0-86400
|
TXP-MR-10G.otn.otnLines.FEC
|
Enable
|
•Disable, Enable when G709OTN is Enable
•Disable when G709OTN is Disable
|
TXP-MR-10G.otn.otnLines.G709OTN
|
Enable
|
Disable, Enable
|
TXP-MR-10G.otn.otnLines.SDBER
|
1.00E-07
|
1E-5, 1E-6, 1E-7, 1E-8, 1E-9
|
TXP-MR-10G.pmthresholds.client.line.farend.15min.CV
|
85040 (B2 count)
|
0-8850600
|
TXP-MR-10G.pmthresholds.client.line.farend.15min.ES
|
87 (seconds)
|
0-900
|
TXP-MR-10G.pmthresholds.client.line.farend.15min.FC
|
10 (count)
|
0-72
|
TXP-MR-10G.pmthresholds.client.line.farend.15min.SES
|
1 (seconds)
|
0-900
|
TXP-MR-10G.pmthresholds.client.line.farend.15min.UAS
|
3 (seconds)
|
0-900
|
TXP-MR-10G.pmthresholds.client.line.farend.1day.CV
|
850400 (B2 count)
|
0-849657600
|
TXP-MR-10G.pmthresholds.client.line.farend.1day.ES
|
864 (seconds)
|
0-86400
|
TXP-MR-10G.pmthresholds.client.line.farend.1day.FC
|
40 (count)
|
0-6912
|
TXP-MR-10G.pmthresholds.client.line.farend.1day.SES
|
4 (seconds)
|
0-86400
|
TXP-MR-10G.pmthresholds.client.line.farend.1day.UAS
|
10 (seconds)
|
0-86400
|
TXP-MR-10G.pmthresholds.client.line.nearend.15min.CV
|
85040 (B2 count)
|
0-8850600
|
TXP-MR-10G.pmthresholds.client.line.nearend.15min.ES
|
87 (seconds)
|
0-900
|
TXP-MR-10G.pmthresholds.client.line.nearend.15min.FC
|
10 (count)
|
0-72
|
TXP-MR-10G.pmthresholds.client.line.nearend.15min.SES
|
1 (seconds)
|
0-900
|
TXP-MR-10G.pmthresholds.client.line.nearend.15min.UAS
|
3 (seconds)
|
0-900
|
TXP-MR-10G.pmthresholds.client.line.nearend.1day.CV
|
850400 (B2 count)
|
0-849657600
|
TXP-MR-10G.pmthresholds.client.line.nearend.1day.ES
|
864 (seconds)
|
0-86400
|
TXP-MR-10G.pmthresholds.client.line.nearend.1day.FC
|
40 (count)
|
0-6912
|
TXP-MR-10G.pmthresholds.client.line.nearend.1day.SES
|
4 (seconds)
|
0-86400
|
TXP-MR-10G.pmthresholds.client.line.nearend.1day.UAS
|
10 (seconds)
|
0-86400
|
TXP-MR-10G.pmthresholds.client.section.nearend.15min.CV
|
10000 (B1 count)
|
0-7967700
|
TXP-MR-10G.pmthresholds.client.section.nearend.15min.ES
|
500 (seconds)
|
0-900
|
TXP-MR-10G.pmthresholds.client.section.nearend.15min.SEFS
|
500 (seconds)
|
0-900
|
TXP-MR-10G.pmthresholds.client.section.nearend.15min.SES
|
500 (seconds)
|
0-900
|
TXP-MR-10G.pmthresholds.client.section.nearend.1day.CV
|
100000 (B1 count)
|
0-764899200
|
TXP-MR-10G.pmthresholds.client.section.nearend.1day.ES
|
5000 (seconds)
|
0-86400
|
TXP-MR-10G.pmthresholds.client.section.nearend.1day.SEFS
|
5000 (seconds)
|
0-86400
|
TXP-MR-10G.pmthresholds.client.section.nearend.1day.SES
|
5000 (seconds)
|
0-86400
|
TXP-MR-10G.pmthresholds.trunk.line.farend.15min.CV
|
85040 (B2 count)
|
0-8850600
|
TXP-MR-10G.pmthresholds.trunk.line.farend.15min.ES
|
87 (seconds)
|
0-900
|
TXP-MR-10G.pmthresholds.trunk.line.farend.15min.FC
|
10 (count)
|
0-72
|
TXP-MR-10G.pmthresholds.trunk.line.farend.15min.SES
|
1 (seconds)
|
0-900
|
TXP-MR-10G.pmthresholds.trunk.line.farend.15min.UAS
|
3 (seconds)
|
0-900
|
TXP-MR-10G.pmthresholds.trunk.line.farend.1day.CV
|
850400 (B2 count)
|
0-849657600
|
TXP-MR-10G.pmthresholds.trunk.line.farend.1day.ES
|
864 (seconds)
|
0-86400
|
TXP-MR-10G.pmthresholds.trunk.line.farend.1day.FC
|
40 (count)
|
0-6912
|
TXP-MR-10G.pmthresholds.trunk.line.farend.1day.SES
|
4 (seconds)
|
0-86400
|
TXP-MR-10G.pmthresholds.trunk.line.farend.1day.UAS
|
10 (seconds)
|
0-86400
|
TXP-MR-10G.pmthresholds.trunk.line.nearend.15min.CV
|
85040 (B2 count)
|
0-8850600
|
TXP-MR-10G.pmthresholds.trunk.line.nearend.15min.ES
|
87 (seconds)
|
0-900
|
TXP-MR-10G.pmthresholds.trunk.line.nearend.15min.FC
|
10 (count)
|
0-72
|
TXP-MR-10G.pmthresholds.trunk.line.nearend.15min.SES
|
1 (seconds)
|
0-900
|
TXP-MR-10G.pmthresholds.trunk.line.nearend.15min.UAS
|
3 (seconds)
|
0-900
|
TXP-MR-10G.pmthresholds.trunk.line.nearend.1day.CV
|
850400 (B2 count)
|
0-849657600
|
TXP-MR-10G.pmthresholds.trunk.line.nearend.1day.ES
|
864 (seconds)
|
0-86400
|
TXP-MR-10G.pmthresholds.trunk.line.nearend.1day.FC
|
40 (count)
|
0-6912
|
TXP-MR-10G.pmthresholds.trunk.line.nearend.1day.SES
|
4 (seconds)
|
0-86400
|
TXP-MR-10G.pmthresholds.trunk.line.nearend.1day.UAS
|
10 (seconds)
|
0-86400
|
TXP-MR-10G.pmthresholds.trunk.section.nearend.15min.CV
|
10000 (B1 count)
|
0-7967700
|
TXP-MR-10G.pmthresholds.trunk.section.nearend.15min.ES
|
500 (seconds)
|
0-900
|
TXP-MR-10G.pmthresholds.trunk.section.nearend.15min.SEFS
|
500 (seconds)
|
0-900
|
TXP-MR-10G.pmthresholds.trunk.section.nearend.15min.SES
|
500 (seconds)
|
0-900
|
TXP-MR-10G.pmthresholds.trunk.section.nearend.1day.CV
|
100000 (B1 count)
|
0-764899200
|
TXP-MR-10G.pmthresholds.trunk.section.nearend.1day.ES
|
5000 (seconds)
|
0-86400
|
TXP-MR-10G.pmthresholds.trunk.section.nearend.1day.SEFS
|
5000 (seconds)
|
0-86400
|
TXP-MR-10G.pmthresholds.trunk.section.nearend.1day.SES
|
5000 (seconds)
|
0-86400
|
D.2.1.7 TXP_MR_2.5G Card Default Settings
Table D-7 lists the TXP_MR_2.5G card default settings.
Table D-7 TXP_MR_2.5G Card Default Settings (ANSI)
Default Name
|
Default Value
|
Default Domain
|
TXP-MR-2_5G.config.client.AINSSoakTime
|
08:00 (hours:mins)
|
00:00, 00:15, 00:30 .. 48:00
|
TXP-MR-2_5G.config.client.AlsMode
|
Disabled
|
Disabled, Auto Restart, Manual Restart, Manual Restart for Test
|
TXP-MR-2_5G.config.client.AlsRecoveryPulseDuration
|
40.0 (seconds)
|
•2.0, 2.1, 2.2 .. 100.0 when AlsMode is Disabled, Auto Restart, Manual Restart
•80.0, 80.1, 80.2 .. 100.0 when AlsMode is Manual Restart for Test
|
TXP-MR-2_5G.config.client.AlsRecoveryPulseInterval
|
100 (seconds)
|
60-300
|
TXP-MR-2_5G.config.client.ppmPortAssignment
|
UNASSIGNED
|
UNASSIGNED, OC3_PORT, OC12_PORT, OC48_PORT, ONE_GE_PORT, ESCON_PORT, DV6000_PORT, SDI_D1_VIDEO_PORT, HDTV_PORT, PASS_THRU_PORT, ETR_CLO_PORT, ISC compat, FC1G_PORT, FC2G_PORT, FICON1G_PORT, FICON2G_PORT, ISC peer
|
TXP-MR-2_5G.config.client.ppmSlotAssignment
|
UNASSIGNED
|
UNASSIGNED, PPM (1 Port)
|
TXP-MR-2_5G.config.client.SDBER
|
1.00E-07
|
1E-5, 1E-6, 1E-7, 1E-8, 1E-9
|
TXP-MR-2_5G.config.client.SFBER
|
1.00E-04
|
1E-3, 1E-4, 1E-5
|
TXP-MR-2_5G.config.client.TerminationMode
|
Transparent
|
•Transparent, Section, Line when ppmPortAssignment is UNASSIGNED, OC3_PORT, OC12_PORT, OC48_PORT
•Transparent when ppmPortAssignment is OC3_PORT, OC12_PORT, OC48_PORT, ONE_GE_PORT, ESCON_PORT, DV6000_PORT, SDI_D1_VIDEO_PORT, HDTV_PORT, PASS_THRU_PORT, ETR_CLO_PORT, ISC compat, FC1G_PORT, FC2G_PORT, FICON1G_PORT, FICON2G_PORT, ISC peer
|
TXP-MR-2_5G.config.trunk.AINSSoakTime
|
08:00 (hours:mins)
|
00:00, 00:15, 00:30 .. 48:00
|
TXP-MR-2_5G.config.trunk.AlsMode
|
Disabled
|
Disabled, Auto Restart, Manual Restart, Manual Restart for Test
|
TXP-MR-2_5G.config.trunk.AlsRecoveryPulseDuration
|
40.0 (seconds)
|
•2.0, 2.1, 2.2 .. 100.0 when AlsMode is Disabled, Auto Restart, Manual Restart
•80.0, 80.1, 80.2 .. 100.0 when AlsMode is Manual Restart for Test
|
TXP-MR-2_5G.config.trunk.AlsRecoveryPulseInterval
|
100 (seconds)
|
60-300
|
TXP-MR-2_5G.config.trunk.SDBER
|
1.00E-07
|
1E-5, 1E-6, 1E-7, 1E-8, 1E-9
|
TXP-MR-2_5G.config.trunk.SFBER
|
1.00E-04
|
1E-3, 1E-4, 1E-5
|
TXP-MR-2_5G.opticalthresholds.client.alarm.HighLaserBias
|
90.0 (%)
|
0.0, 0.1, 0.2 .. 100.0
|
TXP-MR-2_5G.opticalthresholds.client.alarm.HighRxPower
|
3.0 (dBm)
|
LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0
|
TXP-MR-2_5G.opticalthresholds.client.alarm.HighTxPower
|
3.0 (dBm)
|
LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0
|
TXP-MR-2_5G.opticalthresholds.client.alarm.LowRxPower
|
-21.0 (dBm)
|
-40.0, -39.9, -39.8 .. HighRxPower
|
TXP-MR-2_5G.opticalthresholds.client.alarm.LowTxPower
|
-15.0 (dBm)
|
-40.0, -39.9, -39.8 .. HighTxPower
|
TXP-MR-2_5G.opticalthresholds.client.warning.15min.HighLaserBias
|
81.0 (%)
|
0.0, 0.1, 0.2 .. 100.0
|
TXP-MR-2_5G.opticalthresholds.client.warning.15min.HighRxPower
|
2.0 (dBm)
|
LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0
|
TXP-MR-2_5G.opticalthresholds.client.warning.15min.HighTxPower
|
2.0 (dBm)
|
LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0
|
TXP-MR-2_5G.opticalthresholds.client.warning.15min.LowRxPower
|
-20.0 (dBm)
|
-40.0, -39.9, -39.8 .. HighRxPower
|
TXP-MR-2_5G.opticalthresholds.client.warning.15min.LowTxPower
|
-7.0 (dBm)
|
-40.0, -39.9, -39.8 .. HighTxPower
|
TXP-MR-2_5G.opticalthresholds.client.warning.1day.HighLaserBias
|
85.5 (%)
|
0.0, 0.1, 0.2 .. 100.0
|
TXP-MR-2_5G.opticalthresholds.client.warning.1day.HighRxPower
|
2.5 (dBm)
|
LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0
|
TXP-MR-2_5G.opticalthresholds.client.warning.1day.HighTxPower
|
2.5 (dBm)
|
LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0
|
TXP-MR-2_5G.opticalthresholds.client.warning.1day.LowRxPower
|
-20.5 (dBm)
|
-40.0, -39.9, -39.8 .. HighRxPower
|
TXP-MR-2_5G.opticalthresholds.client.warning.1day.LowTxPower
|
-7.5 (dBm)
|
-40.0, -39.9, -39.8 .. HighTxPower
|
TXP-MR-2_5G.opticalthresholds.trunk.alarm.HighLaserBias
|
98.0 (%)
|
0.0, 0.1, 0.2 .. 100.0
|
TXP-MR-2_5G.opticalthresholds.trunk.alarm.HighRxPower
|
-8.0 (dBrn)
|
LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0
|
TXP-MR-2_5G.opticalthresholds.trunk.alarm.LowRxPower
|
-25.0 (dBrn)
|
-40.0, -39.9, -39.8 .. HighRxPower
|
TXP-MR-2_5G.opticalthresholds.trunk.warning.15min.HighLaserBias
|
95.0 (%)
|
0.0, 0.1, 0.2 .. 100.0
|
TXP-MR-2_5G.opticalthresholds.trunk.warning.15min.HighRxPower
|
-7.5 (dBrn)
|
LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0
|
TXP-MR-2_5G.opticalthresholds.trunk.warning.15min.LowRxPower
|
-24.5 (dBrn)
|
-40.0, -39.9, -39.8 .. HighRxPower
|
TXP-MR-2_5G.opticalthresholds.trunk.warning.1day.HighLaserBias
|
96.0 (%)
|
0.0, 0.1, 0.2 .. 100.0
|
TXP-MR-2_5G.opticalthresholds.trunk.warning.1day.HighRxPower
|
-7.3 (dBrn)
|
LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0
|
TXP-MR-2_5G.opticalthresholds.trunk.warning.1day.LowRxPower
|
-24.7 (dBrn)
|
-40.0, -39.9, -39.8 .. HighRxPower
|
TXP-MR-2_5G.otn.fecthresholds.1gethernet.15min.BitErrorsCorrected
|
112500 (count)
|
0-9033621811200
|
TXP-MR-2_5G.otn.fecthresholds.1gethernet.15min.UncorrectableWords
|
1 (count)
|
0-4724697600
|
TXP-MR-2_5G.otn.fecthresholds.1gethernet.1day.BitErrorsCorrected
|
10800000 (count)
|
0-867227693875200
|
TXP-MR-2_5G.otn.fecthresholds.1gethernet.1day.UncorrectableWords
|
96 (count)
|
0-453570969600
|
TXP-MR-2_5G.otn.fecthresholds.1gfiberchannel.15min.BitErrorsCorrected
|
90000 (count)
|
0-9033621811200
|
TXP-MR-2_5G.otn.fecthresholds.1gfiberchannel.15min.UncorrectableWords
|
1 (count)
|
0-4724697600
|
TXP-MR-2_5G.otn.fecthresholds.1gfiberchannel.1day.BitErrorsCorrected
|
8640000 (count)
|
0-867227693875200
|
TXP-MR-2_5G.otn.fecthresholds.1gfiberchannel.1day.UncorrectableWords
|
96 (count)
|
0-453570969600
|
TXP-MR-2_5G.otn.fecthresholds.1gficon.15min.BitErrorsCorrected
|
90000 (count)
|
0-9033621811200
|
TXP-MR-2_5G.otn.fecthresholds.1gficon.15min.UncorrectableWords
|
1 (count)
|
0-4724697600
|
TXP-MR-2_5G.otn.fecthresholds.1gficon.1day.BitErrorsCorrected
|
8640000 (count)
|
0-867227693875200
|
TXP-MR-2_5G.otn.fecthresholds.1gficon.1day.UncorrectableWords
|
96 (count)
|
0-453570969600
|
TXP-MR-2_5G.otn.fecthresholds.2gfiberchannel.15min.BitErrorsCorrected
|
180900 (count)
|
0-9033621811200
|
TXP-MR-2_5G.otn.fecthresholds.2gfiberchannel.15min.UncorrectableWords
|
1 (count)
|
0-4724697600
|
TXP-MR-2_5G.otn.fecthresholds.2gfiberchannel.1day.BitErrorsCorrected
|
17366400 (count)
|
0-867227693875200
|
TXP-MR-2_5G.otn.fecthresholds.2gfiberchannel.1day.UncorrectableWords
|
96 (count)
|
0-453570969600
|
TXP-MR-2_5G.otn.fecthresholds.2gficon.15min.BitErrorsCorrected
|
180900 (count)
|
0-9033621811200
|
TXP-MR-2_5G.otn.fecthresholds.2gficon.15min.UncorrectableWords
|
1 (count)
|
0-4724697600
|
TXP-MR-2_5G.otn.fecthresholds.2gficon.1day.BitErrorsCorrected
|
17366400 (count)
|
0-867227693875200
|
TXP-MR-2_5G.otn.fecthresholds.2gficon.1day.UncorrectableWords
|
96 (count)
|
0-453570969600
|
TXP-MR-2_5G.otn.fecthresholds.oc12.15min.BitErrorsCorrected
|
56457 (count)
|
0-9033621811200
|
TXP-MR-2_5G.otn.fecthresholds.oc12.15min.UncorrectableWords
|
1 (count)
|
0-4724697600
|
TXP-MR-2_5G.otn.fecthresholds.oc12.1day.BitErrorsCorrected
|
5419872 (count)
|
0-867227693875200
|
TXP-MR-2_5G.otn.fecthresholds.oc12.1day.UncorrectableWords
|
96 (count)
|
0-453570969600
|
TXP-MR-2_5G.otn.fecthresholds.oc3.15min.BitErrorsCorrected
|
15012 (count)
|
0-9033621811200
|
TXP-MR-2_5G.otn.fecthresholds.oc3.15min.UncorrectableWords
|
1 (count)
|
0-4724697600
|
TXP-MR-2_5G.otn.fecthresholds.oc3.1day.BitErrorsCorrected
|
1441152 (count)
|
0-867227693875200
|
TXP-MR-2_5G.otn.fecthresholds.oc3.1day.UncorrectableWords
|
96 (count)
|
0-453570969600
|
TXP-MR-2_5G.otn.fecthresholds.oc48.15min.BitErrorsCorrected
|
225837 (count)
|
0-9033621811200
|
TXP-MR-2_5G.otn.fecthresholds.oc48.15min.UncorrectableWords
|
1 (count)
|
0-4724697600
|
TXP-MR-2_5G.otn.fecthresholds.oc48.1day.BitErrorsCorrected
|
21680352 (count)
|
0-867227693875200
|
TXP-MR-2_5G.otn.fecthresholds.oc48.1day.UncorrectableWords
|
96 (count)
|
0-453570969600
|
TXP-MR-2_5G.otn.g709thresholds.pm.farend.15min.BBE
|
21260 (count)
|
0-8850600
|
TXP-MR-2_5G.otn.g709thresholds.pm.farend.15min.ES
|
87 (seconds)
|
0-900
|
TXP-MR-2_5G.otn.g709thresholds.pm.farend.15min.FC
|
10 (count)
|
0-72
|
TXP-MR-2_5G.otn.g709thresholds.pm.farend.15min.SES
|
1 (seconds)
|
0-900
|
TXP-MR-2_5G.otn.g709thresholds.pm.farend.15min.UAS
|
3 (seconds)
|
0-900
|
TXP-MR-2_5G.otn.g709thresholds.pm.farend.1day.BBE
|
212600 (count)
|
0-849657600
|
TXP-MR-2_5G.otn.g709thresholds.pm.farend.1day.ES
|
864 (seconds)
|
0-86400
|
TXP-MR-2_5G.otn.g709thresholds.pm.farend.1day.FC
|
40 (count)
|
0-6912
|
TXP-MR-2_5G.otn.g709thresholds.pm.farend.1day.SES
|
4 (seconds)
|
0-86400
|
TXP-MR-2_5G.otn.g709thresholds.pm.farend.1day.UAS
|
10 (seconds)
|
0-86400
|
TXP-MR-2_5G.otn.g709thresholds.pm.nearend.15min.BBE
|
21260 (count)
|
0-8850600
|
TXP-MR-2_5G.otn.g709thresholds.pm.nearend.15min.ES
|
87 (seconds)
|
0-900
|
TXP-MR-2_5G.otn.g709thresholds.pm.nearend.15min.FC
|
10 (count)
|
0-72
|
TXP-MR-2_5G.otn.g709thresholds.pm.nearend.15min.SES
|
1 (seconds)
|
0-900
|
TXP-MR-2_5G.otn.g709thresholds.pm.nearend.15min.UAS
|
3 (seconds)
|
0-900
|
TXP-MR-2_5G.otn.g709thresholds.pm.nearend.1day.BBE
|
212600 (count)
|
0-849657600
|
TXP-MR-2_5G.otn.g709thresholds.pm.nearend.1day.ES
|
864 (seconds)
|
0-86400
|
TXP-MR-2_5G.otn.g709thresholds.pm.nearend.1day.FC
|
40 (count)
|
0-6912
|
TXP-MR-2_5G.otn.g709thresholds.pm.nearend.1day.SES
|
4 (seconds)
|
0-86400
|
TXP-MR-2_5G.otn.g709thresholds.pm.nearend.1day.UAS
|
10 (seconds)
|
0-86400
|
TXP-MR-2_5G.otn.g709thresholds.sm.farend.15min.BBE
|
10000 (count)
|
0-8850600
|
TXP-MR-2_5G.otn.g709thresholds.sm.farend.15min.ES
|
500 (seconds)
|
0-900
|
TXP-MR-2_5G.otn.g709thresholds.sm.farend.15min.FC
|
10 (count)
|
0-72
|
TXP-MR-2_5G.otn.g709thresholds.sm.farend.15min.SES
|
500 (seconds)
|
0-900
|
TXP-MR-2_5G.otn.g709thresholds.sm.farend.15min.UAS
|
500 (seconds)
|
0-900
|
TXP-MR-2_5G.otn.g709thresholds.sm.farend.1day.BBE
|
100000 (count)
|
0-849657600
|
TXP-MR-2_5G.otn.g709thresholds.sm.farend.1day.ES
|
5000 (seconds)
|
0-86400
|
TXP-MR-2_5G.otn.g709thresholds.sm.farend.1day.FC
|
40 (count)
|
0-6912
|
TXP-MR-2_5G.otn.g709thresholds.sm.farend.1day.SES
|
5000 (seconds)
|
0-86400
|
TXP-MR-2_5G.otn.g709thresholds.sm.farend.1day.UAS
|
5000 (seconds)
|
0-86400
|
TXP-MR-2_5G.otn.g709thresholds.sm.nearend.15min.BBE
|
10000 (count)
|
0-8850600
|
TXP-MR-2_5G.otn.g709thresholds.sm.nearend.15min.ES
|
500 (seconds)
|
0-900
|
TXP-MR-2_5G.otn.g709thresholds.sm.nearend.15min.FC
|
10 (count)
|
0-72
|
TXP-MR-2_5G.otn.g709thresholds.sm.nearend.15min.SES
|
500 (seconds)
|
0-900
|
TXP-MR-2_5G.otn.g709thresholds.sm.nearend.15min.UAS
|
500 (seconds)
|
0-900
|
TXP-MR-2_5G.otn.g709thresholds.sm.nearend.1day.BBE
|
100000 (count)
|
0-849657600
|
TXP-MR-2_5G.otn.g709thresholds.sm.nearend.1day.ES
|
5000 (seconds)
|
0-86400
|
TXP-MR-2_5G.otn.g709thresholds.sm.nearend.1day.FC
|
40 (count)
|
0-6912
|
TXP-MR-2_5G.otn.g709thresholds.sm.nearend.1day.SES
|
5000 (seconds)
|
0-86400
|
TXP-MR-2_5G.otn.g709thresholds.sm.nearend.1day.UAS
|
5000 (seconds)
|
0-86400
|
TXP-MR-2_5G.otn.otnLines.FEC
|
Enable
|
•Disable, Enable when G709OTN is Enable
•Disable when G709OTN is Disable
|
TXP-MR-2_5G.otn.otnLines.G709OTN
|
Enable
|
Disable, Enable
|
TXP-MR-2_5G.otn.otnLines.SDBER
|
1.00E-07
|
1E-5, 1E-6, 1E-7, 1E-8, 1E-9
|
TXP-MR-2_5G.pmthresholds.oc12.line.farend.15min.CV
|
5315 (B2 count)
|
0-552600
|
TXP-MR-2_5G.pmthresholds.oc12.line.farend.15min.ES
|
87 (seconds)
|
0-900
|
TXP-MR-2_5G.pmthresholds.oc12.line.farend.15min.FC
|
10 (count)
|
0-72
|
TXP-MR-2_5G.pmthresholds.oc12.line.farend.15min.SES
|
1 (seconds)
|
0-900
|
TXP-MR-2_5G.pmthresholds.oc12.line.farend.15min.UAS
|
3 (seconds)
|
0-900
|
TXP-MR-2_5G.pmthresholds.oc12.line.farend.1day.CV
|
53150 (B2 count)
|
0-53049600
|
TXP-MR-2_5G.pmthresholds.oc12.line.farend.1day.ES
|
864 (seconds)
|
0-86400
|
TXP-MR-2_5G.pmthresholds.oc12.line.farend.1day.FC
|
40 (count)
|
0-72
|
TXP-MR-2_5G.pmthresholds.oc12.line.farend.1day.SES
|
4 (seconds)
|
0-86400
|
TXP-MR-2_5G.pmthresholds.oc12.line.farend.1day.UAS
|
10 (seconds)
|
0-86400
|
TXP-MR-2_5G.pmthresholds.oc12.line.nearend.15min.CV
|
5315 (B2 count)
|
0-552600
|
TXP-MR-2_5G.pmthresholds.oc12.line.nearend.15min.ES
|
87 (seconds)
|
0-900
|
TXP-MR-2_5G.pmthresholds.oc12.line.nearend.15min.FC
|
10 (count)
|
0-72
|
TXP-MR-2_5G.pmthresholds.oc12.line.nearend.15min.SES
|
1 (seconds)
|
0-900
|
TXP-MR-2_5G.pmthresholds.oc12.line.nearend.15min.UAS
|
3 (seconds)
|
0-900
|
TXP-MR-2_5G.pmthresholds.oc12.line.nearend.1day.CV
|
53150 (B2 count)
|
0-53049600
|
TXP-MR-2_5G.pmthresholds.oc12.line.nearend.1day.ES
|
864 (seconds)
|
0-86400
|
TXP-MR-2_5G.pmthresholds.oc12.line.nearend.1day.FC
|
40 (count)
|
0-6912
|
TXP-MR-2_5G.pmthresholds.oc12.line.nearend.1day.SES
|
4 (seconds)
|
0-86400
|
TXP-MR-2_5G.pmthresholds.oc12.line.nearend.1day.UAS
|
10 (seconds)
|
0-86400
|
TXP-MR-2_5G.pmthresholds.oc12.section.nearend.15min.CV
|
10000 (B1 count)
|
0-553500
|
TXP-MR-2_5G.pmthresholds.oc12.section.nearend.15min.ES
|
500 (seconds)
|
0-900
|
TXP-MR-2_5G.pmthresholds.oc12.section.nearend.15min.SEFS
|
500 (seconds)
|
0-900
|
TXP-MR-2_5G.pmthresholds.oc12.section.nearend.15min.SES
|
500 (seconds)
|
0-900
|
TXP-MR-2_5G.pmthresholds.oc12.section.nearend.1day.CV
|
100000 (B1 count)
|
0-53136000
|
TXP-MR-2_5G.pmthresholds.oc12.section.nearend.1day.ES
|
5000 (seconds)
|
0-86400
|
TXP-MR-2_5G.pmthresholds.oc12.section.nearend.1day.SEFS
|
5000 (seconds)
|
0-86400
|
TXP-MR-2_5G.pmthresholds.oc12.section.nearend.1day.SES
|
5000 (seconds)
|
0-86400
|
TXP-MR-2_5G.pmthresholds.oc3.line.farend.15min.CV
|
1312 (B2 count)
|
0-137700
|
TXP-MR-2_5G.pmthresholds.oc3.line.farend.15min.ES
|
87 (seconds)
|
0-900
|
TXP-MR-2_5G.pmthresholds.oc3.line.farend.15min.FC
|
10 (count)
|
0-72
|
TXP-MR-2_5G.pmthresholds.oc3.line.farend.15min.SES
|
1 (seconds)
|
0-900
|
TXP-MR-2_5G.pmthresholds.oc3.line.farend.15min.UAS
|
3 (seconds)
|
0-900
|
TXP-MR-2_5G.pmthresholds.oc3.line.farend.1day.CV
|
13120 (B2 count)
|
0-13219200
|
TXP-MR-2_5G.pmthresholds.oc3.line.farend.1day.ES
|
864 (seconds)
|
0-86400
|
TXP-MR-2_5G.pmthresholds.oc3.line.farend.1day.FC
|
40 (count)
|
0-6912
|
TXP-MR-2_5G.pmthresholds.oc3.line.farend.1day.SES
|
4 (seconds)
|
0-86400
|
TXP-MR-2_5G.pmthresholds.oc3.line.farend.1day.UAS
|
10 (seconds)
|
0-86400
|
TXP-MR-2_5G.pmthresholds.oc3.line.nearend.15min.CV
|
1312 (B2 count)
|
0-137700
|
TXP-MR-2_5G.pmthresholds.oc3.line.nearend.15min.ES
|
87 (seconds)
|
0-900
|
TXP-MR-2_5G.pmthresholds.oc3.line.nearend.15min.FC
|
10 (count)
|
0-72
|
TXP-MR-2_5G.pmthresholds.oc3.line.nearend.15min.SES
|
1 (seconds)
|
0-900
|
TXP-MR-2_5G.pmthresholds.oc3.line.nearend.15min.UAS
|
3 (seconds)
|
0-900
|
TXP-MR-2_5G.pmthresholds.oc3.line.nearend.1day.CV
|
13120 (B2 count)
|
0-13219200
|
TXP-MR-2_5G.pmthresholds.oc3.line.nearend.1day.ES
|
864 (seconds)
|
0-86400
|
TXP-MR-2_5G.pmthresholds.oc3.line.nearend.1day.FC
|
40 (count)
|
0-6912
|
TXP-MR-2_5G.pmthresholds.oc3.line.nearend.1day.SES
|
4 (seconds)
|
0-86400
|
TXP-MR-2_5G.pmthresholds.oc3.line.nearend.1day.UAS
|
10 (seconds)
|
0-86400
|
TXP-MR-2_5G.pmthresholds.oc3.section.nearend.15min.CV
|
10000 (B1 count)
|
0-138600
|
TXP-MR-2_5G.pmthresholds.oc3.section.nearend.15min.ES
|
500 (seconds)
|
0-900
|
TXP-MR-2_5G.pmthresholds.oc3.section.nearend.15min.SEFS
|
500 (seconds)
|
0-900
|
TXP-MR-2_5G.pmthresholds.oc3.section.nearend.15min.SES
|
500 (seconds)
|
0-900
|
TXP-MR-2_5G.pmthresholds.oc3.section.nearend.1day.CV
|
100000 (B1 count)
|
0-13305600
|
TXP-MR-2_5G.pmthresholds.oc3.section.nearend.1day.ES
|
5000 (seconds)
|
0-86400
|
TXP-MR-2_5G.pmthresholds.oc3.section.nearend.1day.SEFS
|
5000 (seconds)
|
0-86400
|
TXP-MR-2_5G.pmthresholds.oc3.section.nearend.1day.SES
|
5000 (seconds)
|
0-86400
|
TXP-MR-2_5G.pmthresholds.oc48.line.farend.15min.CV
|
21260 (B2 count)
|
0-2212200
|
TXP-MR-2_5G.pmthresholds.oc48.line.farend.15min.ES
|
87 (seconds)
|
0-900
|
TXP-MR-2_5G.pmthresholds.oc48.line.farend.15min.FC
|
10 (count)
|
0-72
|
TXP-MR-2_5G.pmthresholds.oc48.line.farend.15min.SES
|
1 (seconds)
|
0-900
|
TXP-MR-2_5G.pmthresholds.oc48.line.farend.15min.UAS
|
3 (seconds)
|
0-900
|
TXP-MR-2_5G.pmthresholds.oc48.line.farend.1day.CV
|
212600 (B2 count)
|
0-212371200
|
TXP-MR-2_5G.pmthresholds.oc48.line.farend.1day.ES
|
864 (seconds)
|
0-86400
|
TXP-MR-2_5G.pmthresholds.oc48.line.farend.1day.FC
|
40 (count)
|
0-6912
|
TXP-MR-2_5G.pmthresholds.oc48.line.farend.1day.SES
|
4 (seconds)
|
0-86400
|
TXP-MR-2_5G.pmthresholds.oc48.line.farend.1day.UAS
|
10 (seconds)
|
0-86400
|
TXP-MR-2_5G.pmthresholds.oc48.line.nearend.15min.CV
|
21260 (B2 count)
|
0-2212200
|
TXP-MR-2_5G.pmthresholds.oc48.line.nearend.15min.ES
|
87 (seconds)
|
0-900
|
TXP-MR-2_5G.pmthresholds.oc48.line.nearend.15min.FC
|
10 (count)
|
0-72
|
TXP-MR-2_5G.pmthresholds.oc48.line.nearend.15min.SES
|
1 (seconds)
|
0-900
|
TXP-MR-2_5G.pmthresholds.oc48.line.nearend.15min.UAS
|
3 (seconds)
|
0-900
|
TXP-MR-2_5G.pmthresholds.oc48.line.nearend.1day.CV
|
212600 (B2 count)
|
0-212371200
|
TXP-MR-2_5G.pmthresholds.oc48.line.nearend.1day.ES
|
864 (seconds)
|
0-86400
|
TXP-MR-2_5G.pmthresholds.oc48.line.nearend.1day.FC
|
40 (count)
|
0-6912
|
TXP-MR-2_5G.pmthresholds.oc48.line.nearend.1day.SES
|
4 (seconds)
|
0-86400
|
TXP-MR-2_5G.pmthresholds.oc48.line.nearend.1day.UAS
|
10 (seconds)
|
0-86400
|
TXP-MR-2_5G.pmthresholds.oc48.section.nearend.15min.CV
|
10000 (B1 count)
|
0-2151900
|
TXP-MR-2_5G.pmthresholds.oc48.section.nearend.15min.ES
|
500 (seconds)
|
0-900
|
TXP-MR-2_5G.pmthresholds.oc48.section.nearend.15min.SEFS
|
500 (seconds)
|
0-900
|
TXP-MR-2_5G.pmthresholds.oc48.section.nearend.15min.SES
|
500 (seconds)
|
0-900
|
TXP-MR-2_5G.pmthresholds.oc48.section.nearend.1day.CV
|
100000 (B1 count)
|
0-206582400
|
TXP-MR-2_5G.pmthresholds.oc48.section.nearend.1day.ES
|
5000 (seconds)
|
0-86400
|
TXP-MR-2_5G.pmthresholds.oc48.section.nearend.1day.SEFS
|
5000 (seconds)
|
0-86400
|
TXP-MR-2_5G.pmthresholds.oc48.section.nearend.1day.SES
|
5000 (seconds)
|
0-86400
|
D.2.1.8 TXPP_MR_2.5G Card Default Settings
Table D-8 lists the TXPP_MR_2.5G card default settings.
Table D-8 TXPP_MR_2.5G Card Default Settings (ANSI)
Default Name
|
Default Value
|
Default Domain
|
TXPP-MR-2_5G.config.client.AINSSoakTime
|
08:00 (hours:mins)
|
00:00, 00:15, 00:30 .. 48:00
|
TXPP-MR-2_5G.config.client.AlsMode
|
Disabled
|
Disabled, Auto Restart, Manual Restart, Manual Restart for Test
|
TXPP-MR-2_5G.config.client.AlsRecoveryPulseDuration
|
40.0 (seconds)
|
•2.0, 2.1, 2.2 .. 100.0 when AlsMode is Disabled, Auto Restart, Manual Restart
•80.0, 80.1, 80.2 .. 100.0 when AlsMode is Manual Restart for Test
|
TXPP-MR-2_5G.config.client.AlsRecoveryPulseInterval
|
100 (seconds)
|
60-300
|
TXPP-MR-2_5G.config.client.ppmPortAssignment
|
UNASSIGNED
|
UNASSIGNED, OC3_PORT, OC12_PORT, OC48_PORT, ONE_GE_PORT, ESCON_PORT, DV6000_PORT, SDI_D1_VIDEO_PORT, HDTV_PORT, PASS_THRU_PORT, ETR_CLO_PORT, ISC compat, FC1G_PORT, FC2G_PORT, FICON1G_PORT, FICON2G_PORT, ISC peer
|
TXPP-MR-2_5G.config.client.ppmSlotAssignment
|
UNASSIGNED
|
UNASSIGNED, PPM (1 Port)
|
TXPP-MR-2_5G.config.client.SDBER
|
1.00E-07
|
1E-5, 1E-6, 1E-7, 1E-8, 1E-9
|
TXPP-MR-2_5G.config.client.SFBER
|
1.00E-04
|
1E-3, 1E-4, 1E-5
|
TXPP-MR-2_5G.config.client.TerminationMode
|
Transparent
|
•Transparent, Section, Line when ppmPortAssignment is UNASSIGNED, OC3_PORT, OC12_PORT, OC48_PORT
•Transparent when ppmPortAssignment is OC3_PORT, OC12_PORT, OC48_PORT, ONE_GE_PORT, ESCON_PORT, DV6000_PORT, SDI_D1_VIDEO_PORT, HDTV_PORT, PASS_THRU_PORT, ETR_CLO_PORT, ISC compat, FC1G_PORT, FC2G_PORT, FICON1G_PORT, FICON2G_PORT, ISC peer
|
TXPP-MR-2_5G.config.trunk.AINSSoakTime
|
08:00 (hours:mins)
|
00:00, 00:15, 00:30 .. 48:00
|
TXPP-MR-2_5G.config.trunk.AlsMode
|
Disabled
|
Disabled, Auto Restart, Manual Restart, Manual Restart for Test
|
TXPP-MR-2_5G.config.trunk.AlsRecoveryPulseDuration
|
40.0 (seconds)
|
•2.0, 2.1, 2.2 .. 100.0 when AlsMode is Disabled, Auto Restart, Manual Restart
•80.0, 80.1, 80.2 .. 100.0 when AlsMode is Manual Restart for Test
|
TXPP-MR-2_5G.config.trunk.AlsRecoveryPulseInterval
|
100 (seconds)
|
60-300
|
TXPP-MR-2_5G.config.trunk.SDBER
|
1.00E-07
|
1E-5, 1E-6, 1E-7, 1E-8, 1E-9
|
TXPP-MR-2_5G.config.trunk.SFBER
|
1.00E-04
|
1E-3, 1E-4, 1E-5
|
TXPP-MR-2_5G.opticalthresholds.client.alarm.HighLaserBias
|
90.0 (%)
|
0.0, 0.1, 0.2 .. 100.0
|
TXPP-MR-2_5G.opticalthresholds.client.alarm.HighRxPower
|
3.0 (dBm)
|
LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0
|
TXPP-MR-2_5G.opticalthresholds.client.alarm.HighTxPower
|
3.0 (dBm)
|
LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0
|
TXPP-MR-2_5G.opticalthresholds.client.alarm.LowRxPower
|
-21.0 (dBm)
|
-40.0, -39.9, -39.8 .. HighRxPower
|
TXPP-MR-2_5G.opticalthresholds.client.alarm.LowTxPower
|
-15.0 (dBm)
|
-40.0, -39.9, -39.8 .. HighTxPower
|
TXPP-MR-2_5G.opticalthresholds.client.warning.15min.HighLaserBias
|
81.0 (%)
|
0.0, 0.1, 0.2 .. 100.0
|
TXPP-MR-2_5G.opticalthresholds.client.warning.15min.HighRxPower
|
2.0 (dBm)
|
LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0
|
TXPP-MR-2_5G.opticalthresholds.client.warning.15min.HighTxPower
|
2.0 (dBm)
|
LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0
|
TXPP-MR-2_5G.opticalthresholds.client.warning.15min.LowRxPower
|
-20.0 (dBm)
|
-40.0, -39.9, -39.8 .. HighRxPower
|
TXPP-MR-2_5G.opticalthresholds.client.warning.15min.LowTxPower
|
-7.0 (dBm)
|
-40.0, -39.9, -39.8 .. HighTxPower
|
TXPP-MR-2_5G.opticalthresholds.client.warning.1day.HighLaserBias
|
85.5 (%)
|
0.0, 0.1, 0.2 .. 100.0
|
TXPP-MR-2_5G.opticalthresholds.client.warning.1day.HighRxPower
|
2.5 (dBm)
|
LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0
|
TXPP-MR-2_5G.opticalthresholds.client.warning.1day.HighTxPower
|
2.5 (dBm)
|
LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0
|
TXPP-MR-2_5G.opticalthresholds.client.warning.1day.LowRxPower
|
-20.5 (dBm)
|
-40.0, -39.9, -39.8 .. HighRxPower
|
TXPP-MR-2_5G.opticalthresholds.client.warning.1day.LowTxPower
|
-7.5 (dBm)
|
-40.0, -39.9, -39.8 .. HighTxPower
|
TXPP-MR-2_5G.opticalthresholds.trunk.alarm.HighLaserBias
|
98.0 (%)
|
0.0, 0.1, 0.2 .. 100.0
|
TXPP-MR-2_5G.opticalthresholds.trunk.alarm.HighRxPower
|
-8.0 (dBrn)
|
LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0
|
TXPP-MR-2_5G.opticalthresholds.trunk.alarm.LowRxPower
|
-25.0 (dBrn)
|
-40.0, -39.9, -39.8 .. HighRxPower
|
TXPP-MR-2_5G.opticalthresholds.trunk.warning.15min.HighLaserBias
|
95.0 (%)
|
0.0, 0.1, 0.2 .. 100.0
|
TXPP-MR-2_5G.opticalthresholds.trunk.warning.15min.HighRxPower
|
-7.5 (dBrn)
|
LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0
|
TXPP-MR-2_5G.opticalthresholds.trunk.warning.15min.LowRxPower
|
-24.5 (dBrn)
|
-40.0, -39.9, -39.8 .. HighRxPower
|
TXPP-MR-2_5G.opticalthresholds.trunk.warning.1day.HighLaserBias
|
96.0 (%)
|
0.0, 0.1, 0.2 .. 100.0
|
TXPP-MR-2_5G.opticalthresholds.trunk.warning.1day.HighRxPower
|
-7.3 (dBrn)
|
LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0
|
TXPP-MR-2_5G.opticalthresholds.trunk.warning.1day.LowRxPower
|
-24.7 (dBrn)
|
-40.0, -39.9, -39.8 .. HighRxPower
|
TXPP-MR-2_5G.otn.fecthresholds.1gethernet.15min.BitErrorsCorrected
|
112500 (count)
|
0-9033621811200
|
TXPP-MR-2_5G.otn.fecthresholds.1gethernet.15min.UncorrectableWords
|
1 (count)
|
0-4724697600
|
TXPP-MR-2_5G.otn.fecthresholds.1gethernet.1day.BitErrorsCorrected
|
10800000 (count)
|
0-867227693875200
|
TXPP-MR-2_5G.otn.fecthresholds.1gethernet.1day.UncorrectableWords
|
96 (count)
|
0-453570969600
|
TXPP-MR-2_5G.otn.fecthresholds.1gfiberchannel.15min.BitErrorsCorrected
|
90000 (count)
|
0-9033621811200
|
TXPP-MR-2_5G.otn.fecthresholds.1gfiberchannel.15min.UncorrectableWords
|
1 (count)
|
0-4724697600
|
TXPP-MR-2_5G.otn.fecthresholds.1gfiberchannel.1day.BitErrorsCorrected
|
8640000 (count)
|
0-867227693875200
|
TXPP-MR-2_5G.otn.fecthresholds.1gfiberchannel.1day.UncorrectableWords
|
96 (count)
|
0-453570969600
|
TXPP-MR-2_5G.otn.fecthresholds.1gficon.15min.BitErrorsCorrected
|
90000 (count)
|
0-9033621811200
|
TXPP-MR-2_5G.otn.fecthresholds.1gficon.15min.UncorrectableWords
|
1 (count)
|
0-4724697600
|
TXPP-MR-2_5G.otn.fecthresholds.1gficon.1day.BitErrorsCorrected
|
8640000 (count)
|
0-867227693875200
|
TXPP-MR-2_5G.otn.fecthresholds.1gficon.1day.UncorrectableWords
|
96 (count)
|
0-453570969600
|
TXPP-MR-2_5G.otn.fecthresholds.2gfiberchannel.15min.BitErrorsCorrected
|
180900 (count)
|
0-9033621811200
|
TXPP-MR-2_5G.otn.fecthresholds.2gfiberchannel.15min.UncorrectableWords
|
1 (count)
|
0-4724697600
|
TXPP-MR-2_5G.otn.fecthresholds.2gfiberchannel.1day.BitErrorsCorrected
|
17366400 (count)
|
0-867227693875200
|
TXPP-MR-2_5G.otn.fecthresholds.2gfiberchannel.1day.UncorrectableWords
|
96 (count)
|
0-453570969600
|
TXPP-MR-2_5G.otn.fecthresholds.2gficon.15min.BitErrorsCorrected
|
180900 (count)
|
0-9033621811200
|
TXPP-MR-2_5G.otn.fecthresholds.2gficon.15min.UncorrectableWords
|
1 (count)
|
0-4724697600
|
TXPP-MR-2_5G.otn.fecthresholds.2gficon.1day.BitErrorsCorrected
|
17366400 (count)
|
0-867227693875200
|
TXPP-MR-2_5G.otn.fecthresholds.2gficon.1day.UncorrectableWords
|
96 (count)
|
0-453570969600
|
TXPP-MR-2_5G.otn.fecthresholds.oc12.15min.BitErrorsCorrected
|
56457 (count)
|
0-9033621811200
|
TXPP-MR-2_5G.otn.fecthresholds.oc12.15min.UncorrectableWords
|
1 (count)
|
0-4724697600
|
TXPP-MR-2_5G.otn.fecthresholds.oc12.1day.BitErrorsCorrected
|
5419872 (count)
|
0-867227693875200
|
TXPP-MR-2_5G.otn.fecthresholds.oc12.1day.UncorrectableWords
|
96 (count)
|
0-453570969600
|
TXPP-MR-2_5G.otn.fecthresholds.oc3.15min.BitErrorsCorrected
|
15012 (count)
|
0-9033621811200
|
TXPP-MR-2_5G.otn.fecthresholds.oc3.15min.UncorrectableWords
|
1 (count)
|
0-4724697600
|
TXPP-MR-2_5G.otn.fecthresholds.oc3.1day.BitErrorsCorrected
|
1441152 (count)
|
0-867227693875200
|
TXPP-MR-2_5G.otn.fecthresholds.oc3.1day.UncorrectableWords
|
96 (count)
|
0-453570969600
|
TXPP-MR-2_5G.otn.fecthresholds.oc48.15min.BitErrorsCorrected
|
225837 (count)
|
0-9033621811200
|
TXPP-MR-2_5G.otn.fecthresholds.oc48.15min.UncorrectableWords
|
1 (count)
|
0-4724697600
|
TXPP-MR-2_5G.otn.fecthresholds.oc48.1day.BitErrorsCorrected
|
21680352 (count)
|
0-867227693875200
|
TXPP-MR-2_5G.otn.fecthresholds.oc48.1day.UncorrectableWords
|
96 (count)
|
0-453570969600
|
TXPP-MR-2_5G.otn.g709thresholds.pm.farend.15min.BBE
|
21260 (count)
|
0-8850600
|
TXPP-MR-2_5G.otn.g709thresholds.pm.farend.15min.ES
|
87 (seconds)
|
0-900
|
TXPP-MR-2_5G.otn.g709thresholds.pm.farend.15min.FC
|
10 (count)
|
0-72
|
TXPP-MR-2_5G.otn.g709thresholds.pm.farend.15min.SES
|
1 (seconds)
|
0-900
|
TXPP-MR-2_5G.otn.g709thresholds.pm.farend.15min.UAS
|
3 (seconds)
|
0-900
|
TXPP-MR-2_5G.otn.g709thresholds.pm.farend.1day.BBE
|
212600 (count)
|
0-849657600
|
TXPP-MR-2_5G.otn.g709thresholds.pm.farend.1day.ES
|
864 (seconds)
|
0-86400
|
TXPP-MR-2_5G.otn.g709thresholds.pm.farend.1day.FC
|
40 (count)
|
0-6912
|
TXPP-MR-2_5G.otn.g709thresholds.pm.farend.1day.SES
|
4 (seconds)
|
0-86400
|
TXPP-MR-2_5G.otn.g709thresholds.pm.farend.1day.UAS
|
10 (seconds)
|
0-86400
|
TXPP-MR-2_5G.otn.g709thresholds.pm.nearend.15min.BBE
|
21260 (count)
|
0-8850600
|
TXPP-MR-2_5G.otn.g709thresholds.pm.nearend.15min.ES
|
87 (seconds)
|
0-900
|
TXPP-MR-2_5G.otn.g709thresholds.pm.nearend.15min.FC
|
10 (count)
|
0-72
|
TXPP-MR-2_5G.otn.g709thresholds.pm.nearend.15min.SES
|
1 (seconds)
|
0-900
|
TXPP-MR-2_5G.otn.g709thresholds.pm.nearend.15min.UAS
|
3 (seconds)
|
0-900
|
TXPP-MR-2_5G.otn.g709thresholds.pm.nearend.1day.BBE
|
212600 (count)
|
0-849657600
|
TXPP-MR-2_5G.otn.g709thresholds.pm.nearend.1day.ES
|
864 (seconds)
|
0-86400
|
TXPP-MR-2_5G.otn.g709thresholds.pm.nearend.1day.FC
|
40 (count)
|
0-6912
|
TXPP-MR-2_5G.otn.g709thresholds.pm.nearend.1day.SES
|
4 (seconds)
|
0-86400
|
TXPP-MR-2_5G.otn.g709thresholds.pm.nearend.1day.UAS
|
10 (seconds)
|
0-86400
|
TXPP-MR-2_5G.otn.g709thresholds.sm.farend.15min.BBE
|
10000 (count)
|
0-8850600
|
TXPP-MR-2_5G.otn.g709thresholds.sm.farend.15min.ES
|
500 (seconds)
|
0-900
|
TXPP-MR-2_5G.otn.g709thresholds.sm.farend.15min.FC
|
10 (count)
|
0-72
|
TXPP-MR-2_5G.otn.g709thresholds.sm.farend.15min.SES
|
500 (seconds)
|
0-900
|
TXPP-MR-2_5G.otn.g709thresholds.sm.farend.15min.UAS
|
500 (seconds)
|
0-900
|
TXPP-MR-2_5G.otn.g709thresholds.sm.farend.1day.BBE
|
100000 (count)
|
0-849657600
|
TXPP-MR-2_5G.otn.g709thresholds.sm.farend.1day.ES
|
5000 (seconds)
|
0-86400
|
TXPP-MR-2_5G.otn.g709thresholds.sm.farend.1day.FC
|
40 (count)
|
0-6912
|
TXPP-MR-2_5G.otn.g709thresholds.sm.farend.1day.SES
|
5000 (seconds)
|
0-86400
|
TXPP-MR-2_5G.otn.g709thresholds.sm.farend.1day.UAS
|
5000 (seconds)
|
0-86400
|
TXPP-MR-2_5G.otn.g709thresholds.sm.nearend.15min.BBE
|
10000 (count)
|
0-8850600
|
TXPP-MR-2_5G.otn.g709thresholds.sm.nearend.15min.ES
|
500 (seconds)
|
0-900
|
TXPP-MR-2_5G.otn.g709thresholds.sm.nearend.15min.FC
|
10 (count)
|
0-72
|
TXPP-MR-2_5G.otn.g709thresholds.sm.nearend.15min.SES
|
500 (seconds)
|
0-900
|
TXPP-MR-2_5G.otn.g709thresholds.sm.nearend.15min.UAS
|
500 (seconds)
|
0-900
|
TXPP-MR-2_5G.otn.g709thresholds.sm.nearend.1day.BBE
|
100000 (count)
|
0-849657600
|
TXPP-MR-2_5G.otn.g709thresholds.sm.nearend.1day.ES
|
5000 (seconds)
|
0-86400
|
TXPP-MR-2_5G.otn.g709thresholds.sm.nearend.1day.FC
|
40 (count)
|
0-6912
|
TXPP-MR-2_5G.otn.g709thresholds.sm.nearend.1day.SES
|
5000 (seconds)
|
0-86400
|
TXPP-MR-2_5G.otn.g709thresholds.sm.nearend.1day.UAS
|
5000 (seconds)
|
0-86400
|
TXPP-MR-2_5G.otn.otnLines.FEC
|
Enable
|
•Disable, Enable when G709OTN is Enable
•Disable when G709OTN is Disable
|
TXPP-MR-2_5G.otn.otnLines.G709OTN
|
Enable
|
Disable, Enable
|
TXPP-MR-2_5G.otn.otnLines.SDBER
|
1.00E-07
|
1E-5, 1E-6, 1E-7, 1E-8, 1E-9
|
TXPP-MR-2_5G.pmthresholds.oc12.line.farend.15min.CV
|
5315 (B2 count)
|
0-552600
|
TXPP-MR-2_5G.pmthresholds.oc12.line.farend.15min.ES
|
87 (seconds)
|
0-900
|
TXPP-MR-2_5G.pmthresholds.oc12.line.farend.15min.FC
|
10 (count)
|
0-72
|
TXPP-MR-2_5G.pmthresholds.oc12.line.farend.15min.SES
|
1 (seconds)
|
0-900
|
TXPP-MR-2_5G.pmthresholds.oc12.line.farend.15min.UAS
|
3 (seconds)
|
0-900
|
TXPP-MR-2_5G.pmthresholds.oc12.line.farend.1day.CV
|
53150 (B2 count)
|
0-53049600
|
TXPP-MR-2_5G.pmthresholds.oc12.line.farend.1day.ES
|
864 (seconds)
|
0-86400
|
TXPP-MR-2_5G.pmthresholds.oc12.line.farend.1day.FC
|
40 (count)
|
0-72
|
TXPP-MR-2_5G.pmthresholds.oc12.line.farend.1day.SES
|
4 (seconds)
|
0-86400
|
TXPP-MR-2_5G.pmthresholds.oc12.line.farend.1day.UAS
|
10 (seconds)
|
0-86400
|
TXPP-MR-2_5G.pmthresholds.oc12.line.nearend.15min.CV
|
5315 (B2 count)
|
0-552600
|
TXPP-MR-2_5G.pmthresholds.oc12.line.nearend.15min.ES
|
87 (seconds)
|
0-900
|
TXPP-MR-2_5G.pmthresholds.oc12.line.nearend.15min.FC
|
10 (count)
|
0-72
|
TXPP-MR-2_5G.pmthresholds.oc12.line.nearend.15min.SES
|
1 (seconds)
|
0-900
|
TXPP-MR-2_5G.pmthresholds.oc12.line.nearend.15min.UAS
|
3 (seconds)
|
0-900
|
TXPP-MR-2_5G.pmthresholds.oc12.line.nearend.1day.CV
|
53150 (B2 count)
|
0-53049600
|
TXPP-MR-2_5G.pmthresholds.oc12.line.nearend.1day.ES
|
864 (seconds)
|
0-86400
|
TXPP-MR-2_5G.pmthresholds.oc12.line.nearend.1day.FC
|
40 (count)
|
0-6912
|
TXPP-MR-2_5G.pmthresholds.oc12.line.nearend.1day.SES
|
4 (seconds)
|
0-86400
|
TXPP-MR-2_5G.pmthresholds.oc12.line.nearend.1day.UAS
|
10 (seconds)
|
0-86400
|
TXPP-MR-2_5G.pmthresholds.oc12.section.nearend.15min.CV
|
10000 (B1 count)
|
0-553500
|
TXPP-MR-2_5G.pmthresholds.oc12.section.nearend.15min.ES
|
500 (seconds)
|
0-900
|
TXPP-MR-2_5G.pmthresholds.oc12.section.nearend.15min.SEFS
|
500 (seconds)
|
0-900
|
TXPP-MR-2_5G.pmthresholds.oc12.section.nearend.15min.SES
|
500 (seconds)
|
0-900
|
TXPP-MR-2_5G.pmthresholds.oc12.section.nearend.1day.CV
|
100000 (B1 count)
|
0-53136000
|
TXPP-MR-2_5G.pmthresholds.oc12.section.nearend.1day.ES
|
5000 (seconds)
|
0-86400
|
TXPP-MR-2_5G.pmthresholds.oc12.section.nearend.1day.SEFS
|
5000 (seconds)
|
0-86400
|
TXPP-MR-2_5G.pmthresholds.oc12.section.nearend.1day.SES
|
5000 (seconds)
|
0-86400
|
TXPP-MR-2_5G.pmthresholds.oc3.line.farend.15min.CV
|
1312 (B2 count)
|
0-137700
|
TXPP-MR-2_5G.pmthresholds.oc3.line.farend.15min.ES
|
87 (seconds)
|
0-900
|
TXPP-MR-2_5G.pmthresholds.oc3.line.farend.15min.FC
|
10 (count)
|
0-72
|
TXPP-MR-2_5G.pmthresholds.oc3.line.farend.15min.SES
|
1 (seconds)
|
0-900
|
TXPP-MR-2_5G.pmthresholds.oc3.line.farend.15min.UAS
|
3 (seconds)
|
0-900
|
TXPP-MR-2_5G.pmthresholds.oc3.line.farend.1day.CV
|
13120 (B2 count)
|
0-13219200
|
TXPP-MR-2_5G.pmthresholds.oc3.line.farend.1day.ES
|
864 (seconds)
|
0-86400
|
TXPP-MR-2_5G.pmthresholds.oc3.line.farend.1day.FC
|
40 (count)
|
0-6912
|
TXPP-MR-2_5G.pmthresholds.oc3.line.farend.1day.SES
|
4 (seconds)
|
0-86400
|
TXPP-MR-2_5G.pmthresholds.oc3.line.farend.1day.UAS
|
10 (seconds)
|
0-86400
|
TXPP-MR-2_5G.pmthresholds.oc3.line.nearend.15min.CV
|
1312 (B2 count)
|
0-137700
|
TXPP-MR-2_5G.pmthresholds.oc3.line.nearend.15min.ES
|
87 (seconds)
|
0-900
|
TXPP-MR-2_5G.pmthresholds.oc3.line.nearend.15min.FC
|
10 (count)
|
0-72
|
TXPP-MR-2_5G.pmthresholds.oc3.line.nearend.15min.SES
|
1 (seconds)
|
0-900
|
TXPP-MR-2_5G.pmthresholds.oc3.line.nearend.15min.UAS
|
3 (seconds)
|
0-900
|
TXPP-MR-2_5G.pmthresholds.oc3.line.nearend.1day.CV
|
13120 (B2 count)
|
0-13219200
|
TXPP-MR-2_5G.pmthresholds.oc3.line.nearend.1day.ES
|
864 (seconds)
|
0-86400
|
TXPP-MR-2_5G.pmthresholds.oc3.line.nearend.1day.FC
|
40 (count)
|
0-6912
|
TXPP-MR-2_5G.pmthresholds.oc3.line.nearend.1day.SES
|
4 (seconds)
|
0-86400
|
TXPP-MR-2_5G.pmthresholds.oc3.line.nearend.1day.UAS
|
10 (seconds)
|
0-86400
|
TXPP-MR-2_5G.pmthresholds.oc3.section.nearend.15min.CV
|
10000 (B1 count)
|
0-138600
|
TXPP-MR-2_5G.pmthresholds.oc3.section.nearend.15min.ES
|
500 (seconds)
|
0-900
|
TXPP-MR-2_5G.pmthresholds.oc3.section.nearend.15min.SEFS
|
500 (seconds)
|
0-900
|
TXPP-MR-2_5G.pmthresholds.oc3.section.nearend.15min.SES
|
500 (seconds)
|
0-900
|
TXPP-MR-2_5G.pmthresholds.oc3.section.nearend.1day.CV
|
100000 (B1 count)
|
0-13305600
|
TXPP-MR-2_5G.pmthresholds.oc3.section.nearend.1day.ES
|
5000 (seconds)
|
0-86400
|
TXPP-MR-2_5G.pmthresholds.oc3.section.nearend.1day.SEFS
|
5000 (seconds)
|
0-86400
|
TXPP-MR-2_5G.pmthresholds.oc3.section.nearend.1day.SES
|
5000 (seconds)
|
0-86400
|
TXPP-MR-2_5G.pmthresholds.oc48.line.farend.15min.CV
|
21260 (B2 count)
|
0-2212200
|
TXPP-MR-2_5G.pmthresholds.oc48.line.farend.15min.ES
|
87 (seconds)
|
0-900
|
TXPP-MR-2_5G.pmthresholds.oc48.line.farend.15min.FC
|
10 (count)
|
0-72
|
TXPP-MR-2_5G.pmthresholds.oc48.line.farend.15min.SES
|
1 (seconds)
|
0-900
|
TXPP-MR-2_5G.pmthresholds.oc48.line.farend.15min.UAS
|
3 (seconds)
|
0-900
|
TXPP-MR-2_5G.pmthresholds.oc48.line.farend.1day.CV
|
212600 (B2 count)
|
0-212371200
|
TXPP-MR-2_5G.pmthresholds.oc48.line.farend.1day.ES
|
864 (seconds)
|
0-86400
|
TXPP-MR-2_5G.pmthresholds.oc48.line.farend.1day.FC
|
40 (count)
|
0-6912
|
TXPP-MR-2_5G.pmthresholds.oc48.line.farend.1day.SES
|
4 (seconds)
|
0-86400
|
TXPP-MR-2_5G.pmthresholds.oc48.line.farend.1day.UAS
|
10 (seconds)
|
0-86400
|
TXPP-MR-2_5G.pmthresholds.oc48.line.nearend.15min.CV
|
21260 (B2 count)
|
0-2212200
|
TXPP-MR-2_5G.pmthresholds.oc48.line.nearend.15min.ES
|
87 (seconds)
|
0-900
|
TXPP-MR-2_5G.pmthresholds.oc48.line.nearend.15min.FC
|
10 (count)
|
0-72
|
TXPP-MR-2_5G.pmthresholds.oc48.line.nearend.15min.SES
|
1 (seconds)
|
0-900
|
TXPP-MR-2_5G.pmthresholds.oc48.line.nearend.15min.UAS
|
3 (seconds)
|
0-900
|
TXPP-MR-2_5G.pmthresholds.oc48.line.nearend.1day.CV
|
212600 (B2 count)
|
0-212371200
|
TXPP-MR-2_5G.pmthresholds.oc48.line.nearend.1day.ES
|
864 (seconds)
|
0-86400
|
TXPP-MR-2_5G.pmthresholds.oc48.line.nearend.1day.FC
|
40 (count)
|
0-6912
|
TXPP-MR-2_5G.pmthresholds.oc48.line.nearend.1day.SES
|
4 (seconds)
|
0-86400
|
TXPP-MR-2_5G.pmthresholds.oc48.line.nearend.1day.UAS
|
10 (seconds)
|
0-86400
|
TXPP-MR-2_5G.pmthresholds.oc48.section.nearend.15min.CV
|
10000 (B1 count)
|
0-2151900
|
TXPP-MR-2_5G.pmthresholds.oc48.section.nearend.15min.ES
|
500 (seconds)
|
0-900
|
TXPP-MR-2_5G.pmthresholds.oc48.section.nearend.15min.SEFS
|
500 (seconds)
|
0-900
|
TXPP-MR-2_5G.pmthresholds.oc48.section.nearend.15min.SES
|
500 (seconds)
|
0-900
|
TXPP-MR-2_5G.pmthresholds.oc48.section.nearend.1day.CV
|
100000 (B1 count)
|
0-206582400
|
TXPP-MR-2_5G.pmthresholds.oc48.section.nearend.1day.ES
|
5000 (seconds)
|
0-86400
|
TXPP-MR-2_5G.pmthresholds.oc48.section.nearend.1day.SEFS
|
5000 (seconds)
|
0-86400
|
TXPP-MR-2_5G.pmthresholds.oc48.section.nearend.1day.SES
|
5000 (seconds)
|
0-86400
|
D.2.1.9 OSCM Card Default Settings
Table D-9 lists the OSCM card default settings.
Table D-9 OSCM Card Default Settings (ANSI)
Default Name
|
Default Value
|
Default Domain
|
OSCM.pmthresholds.line.farend.15min.CV
|
1312 (B2 count)
|
0-137700
|
OSCM.pmthresholds.line.farend.15min.ES
|
87 (seconds)
|
0-900
|
OSCM.pmthresholds.line.farend.15min.FC
|
10 (count)
|
0-72
|
OSCM.pmthresholds.line.farend.15min.SES
|
1 (seconds)
|
0-900
|
OSCM.pmthresholds.line.farend.15min.UAS
|
3 (seconds)
|
0-900
|
OSCM.pmthresholds.line.farend.1day.CV
|
13120 (B2 count)
|
0-13219200
|
OSCM.pmthresholds.line.farend.1day.ES
|
864 (seconds)
|
0-86400
|
OSCM.pmthresholds.line.farend.1day.FC
|
40 (count)
|
0-6912
|
OSCM.pmthresholds.line.farend.1day.SES
|
4 (seconds)
|
0-86400
|
OSCM.pmthresholds.line.farend.1day.UAS
|
10 (seconds)
|
0-86400
|
OSCM.pmthresholds.line.nearend.15min.CV
|
1312 (B2 count)
|
0-137700
|
OSCM.pmthresholds.line.nearend.15min.ES
|
87 (seconds)
|
0-900
|
OSCM.pmthresholds.line.nearend.15min.FC
|
10 (count)
|
0-72
|
OSCM.pmthresholds.line.nearend.15min.SES
|
1 (seconds)
|
0-900
|
OSCM.pmthresholds.line.nearend.15min.UAS
|
3 (seconds)
|
0-900
|
OSCM.pmthresholds.line.nearend.1day.CV
|
13120 (B2 count)
|
0-13219200
|
OSCM.pmthresholds.line.nearend.1day.ES
|
864 (seconds)
|
0-86400
|
OSCM.pmthresholds.line.nearend.1day.FC
|
40 (count)
|
0-6912
|
OSCM.pmthresholds.line.nearend.1day.SES
|
4 (seconds)
|
0-86400
|
OSCM.pmthresholds.line.nearend.1day.UAS
|
10 (seconds)
|
0-86400
|
OSCM.pmthresholds.section.nearend.15min.CV
|
10000 (B1 count)
|
0-138600
|
OSCM.pmthresholds.section.nearend.15min.ES
|
500 (seconds)
|
0-900
|
OSCM.pmthresholds.section.nearend.15min.SEFS
|
500 (seconds)
|
0-900
|
OSCM.pmthresholds.section.nearend.15min.SES
|
500 (seconds)
|
0-900
|
OSCM.pmthresholds.section.nearend.1day.CV
|
100000 (B1 count)
|
0-13305600
|
OSCM.pmthresholds.section.nearend.1day.ES
|
5000 (seconds)
|
0-86400
|
OSCM.pmthresholds.section.nearend.1day.SEFS
|
5000 (seconds)
|
0-86400
|
OSCM.pmthresholds.section.nearend.1day.SES
|
5000 (seconds)
|
0-86400
|
D.2.1.10 OSC-CSM Card Default Settings
Table D-10 lists the OSC-CSM card default settings.
Table D-10 OSC-CSM Card Default Settings (ANSI)
Default Name
|
Default Value
|
Default Domain
|
OSC_CSM.pmthresholds.line.farend.15min.CV
|
1312 (B2 count)
|
0-137700
|
OSC_CSM.pmthresholds.line.farend.15min.ES
|
87 (seconds)
|
0-900
|
OSC_CSM.pmthresholds.line.farend.15min.FC
|
10 (count)
|
0-72
|
OSC_CSM.pmthresholds.line.farend.15min.SES
|
1 (seconds)
|
0-900
|
OSC_CSM.pmthresholds.line.farend.15min.UAS
|
3 (seconds)
|
0-900
|
OSC_CSM.pmthresholds.line.farend.1day.CV
|
13120 (B2 count)
|
0-13219200
|
OSC_CSM.pmthresholds.line.farend.1day.ES
|
864 (seconds)
|
0-86400
|
OSC_CSM.pmthresholds.line.farend.1day.FC
|
40 (count)
|
0-6912
|
OSC_CSM.pmthresholds.line.farend.1day.SES
|
4 (seconds)
|
0-86400
|
OSC_CSM.pmthresholds.line.farend.1day.UAS
|
10 (seconds)
|
0-86400
|
OSC_CSM.pmthresholds.line.nearend.15min.CV
|
1312 (B2 count)
|
0-137700
|
OSC_CSM.pmthresholds.line.nearend.15min.ES
|
87 (seconds)
|
0-900
|
OSC_CSM.pmthresholds.line.nearend.15min.FC
|
10 (count)
|
0-72
|
OSC_CSM.pmthresholds.line.nearend.15min.SES
|
1 (seconds)
|
0-900
|
OSC_CSM.pmthresholds.line.nearend.15min.UAS
|
3 (seconds)
|
0-900
|
OSC_CSM.pmthresholds.line.nearend.1day.CV
|
13120 (B2 count)
|
0-13219200
|
OSC_CSM.pmthresholds.line.nearend.1day.ES
|
864 (seconds)
|
0-86400
|
OSC_CSM.pmthresholds.line.nearend.1day.FC
|
40 (count)
|
0-6912
|
OSC_CSM.pmthresholds.line.nearend.1day.SES
|
4 (seconds)
|
0-86400
|
OSC_CSM.pmthresholds.line.nearend.1day.UAS
|
10 (seconds)
|
0-86400
|
OSC_CSM.pmthresholds.section.nearend.15min.CV
|
10000 (B1 count)
|
0-138600
|
OSC_CSM.pmthresholds.section.nearend.15min.ES
|
500 (seconds)
|
0-900
|
OSC_CSM.pmthresholds.section.nearend.15min.SEFS
|
500 (seconds)
|
0-900
|
OSC_CSM.pmthresholds.section.nearend.15min.SES
|
500 (seconds)
|
0-900
|
OSC_CSM.pmthresholds.section.nearend.1day.CV
|
100000 (B1 count)
|
0-13305600
|
OSC_CSM.pmthresholds.section.nearend.1day.ES
|
5000 (seconds)
|
0-86400
|
OSC_CSM.pmthresholds.section.nearend.1day.SEFS
|
5000 (seconds)
|
0-86400
|
OSC_CSM.pmthresholds.section.nearend.1day.SES
|
5000 (seconds)
|
0-86400
|
D.2.2 ANSI Node Default Settings
Table D-11 lists the node-level default settings for the Cisco ONS 15454. Cisco provides the following types of user-configurable defaults for each Cisco ONS 15454 node:
•Create TL1-Like—Instructs the node to create only cross-connects, allowing the resulting circuits to be in an upgradable state.
•Insert AIS-V on SDP—Instructs the node to insert AIS-V in each VT whenever the carrying STS crosses the signal degrade path BER threshold.
•SDP BER—Defines the node SD path bit error rate.
•Path Protection settings—Set the threshold level for signal degradation and failure for path protection circuits.
•Craft Access Only—Allows CTC connectivity to the node only through the craft access port.
•CTC IP Display Suppression—Prevents display of node IP addresses in CTC (applicable for all users except Superusers).
•Defaults Description—Names the current defaults file on the node.
•Enable Firewall—Enables or disables the use of a firewall for accessing the node.
•Enable Proxy—Enables or disables the use of a proxy server with the node.
•IIOP Listener Port—Sets the Internet Inter-Object Request Broker Protocol (IIOP) listener port number.
•LCD IP setting—Sets the node LCD screen to display the node IP address and use the buttons on the LCD panel, only display the IP address, or suppress display of the IP address.
•Login Warning Message—Warns users at the login screen about the possible legal or contractual ramifications of accessing equipment, systems, or networks without authorization.
•NTP SNTP Server—Sets the IP address of the Network Time Protocol (NTP) Simple Network Time Protocol (SNTP) server to be used with the node.
•Time Zone—Sets the time zone where the node is located.
•Use DST—Enables or disables the use of Daylight Savings Time (DST).
•Use NTP SNTP Server—Enables or disables the use of the specified NTP SNTP server with the node.
•1+1 protection settings—Determine whether 1+1 protected circuits have bidirectional switching, are revertive, and what the reversion time is.
•BLSR Protection settings—Determine whether BLSR-protected circuits are revertive and what the reversion time is at both the ring and span levels.
•Y Cable Protection settings—Determine whether Y-Cable protected circuits have bidirectional switching, are revertive, and what the reversion time is.
•Security Policy settings—Determine the allowable failed logins before lockout, idle user timeout for each user level, optional lockout duration or manual unlock enabled, password reuse and change frequency policies, number of characters difference between the old and new password, password aging by security level, enforced single concurrent session per user, and option to disable inactive user after a set inactivity period.
•BITS Timing settings—Determine the AIS threshold, coding, framing, State, State Out, and LBO settings for BITS1 and BITS2 timing.
•General Timing settings—Determine the mode (External, Line, or Mixed), quality of RES, revertive, reversion time, and SSM message set for node timing.
Note For more information about each individual node setting, see Chapter 10, "Manage the Node."
Table D-11 Node Default Settings (ANSI)
Default Name
|
Default Value
|
Default Domain
|
NODE.circuits.SendPDIP
|
FALSE
|
TRUE, FALSE
|
NODE.circuits.State
|
IS,AINS
|
IS, OOS,DSBLD, OOS,MT, IS,AINS
|
NODE.circuits.upsr.AllowUpsrOverOnePlusOne
|
FALSE
|
TRUE, FALSE
|
NODE.circuits.upsr.ReversionTime
|
5.0 (minutes)
|
0.5, 1.0, 1.5 .. 12.0
|
NODE.circuits.upsr.Revertive
|
FALSE
|
TRUE, FALSE
|
NODE.circuits.upsr.STS_SDBER
|
1.00E-06
|
1E-5, 1E-6, 1E-7, 1E-8, 1E-9
|
NODE.circuits.upsr.STS_SFBER
|
1.00E-04
|
1E-3, 1E-4, 1E-5
|
NODE.circuits.upsr.SwitchOnPDIP
|
FALSE
|
TRUE, FALSE
|
NODE.circuits.upsr.VT_SDBER
|
1.00E-06
|
1E-5, 1E-6, 1E-7, 1E-8
|
NODE.circuits.upsr.VT_SFBER
|
1.00E-04
|
1E-3, 1E-4, 1E-5
|
NODE.general.DefaultsDescription
|
Factory Defaults
|
Free form field
|
NODE.general.InsertAISVOnSDP
|
FALSE
|
TRUE, FALSE
|
NODE.general.NtpSntpServer
|
0.0.0.0
|
IP Address
|
NODE.general.RaiseConditionOnEmptySlot
|
FALSE
|
TRUE, FALSE
|
NODE.general.SDPBER
|
1.00E-06
|
1E-5, 1E-6, 1E-7, 1E-8, 1E-9
|
NODE.general.TimeZone
|
(GMT-08:00) Pacific Time (US & Canada), Tijuana
|
(For applicable time zones, see Table D-24.)
|
NODE.general.UseDST
|
TRUE
|
TRUE, FALSE
|
NODE.network.general.AlarmMissingBackplaneLAN
|
FALSE
|
TRUE, FALSE
|
NODE.network.general.CtcIpDisplaySuppression
|
FALSE
|
TRUE, FALSE
|
NODE.network.general.GatewaySettings
|
None
|
LeaveAsIs, None, ENE, GNE, ProxyOnlyNode
|
NODE.network.general.LcdIpSetting
|
Allow Configuration
|
Allow Configuration, Display Only, Suppress Display
|
NODE.osi.greTunnel.ctc.OspfCost
|
110
|
110, 120, 130 .. 65530
|
NODE.osi.greTunnel.ctc.SubnetMask
|
24 (bits)
|
8, 9, 10 .. 32
|
NODE.osi.lapd.ctc.Mode
|
AITS
|
AITS, UITS
|
NODE.osi.lapd.ctc.MTU
|
512
|
512, 513, 514 .. 1500
|
NODE.osi.lapd.ctc.Role
|
Network
|
Network, User
|
NODE.osi.lapd.ctc.T200
|
200 (ms)
|
200, 300, 400 .. 20000
|
NODE.osi.lapd.ctc.T203
|
10000 (ms)
|
4000, 4100, 4200 .. 120000
|
NODE.osi.mainSetup.L1L2LSPBufferSize
|
512 (bytes)
|
512-1500
|
NODE.osi.mainSetup.L1LSPBufferSize
|
512 (bytes)
|
512-1500
|
NODE.osi.mainSetup.NodeRoutingMode
|
Intermediate System Level 1
|
End System, Intermediate System Level 1, Intermediate System Level 1/Level 2
|
NODE.osi.subnet.ctc.DISPriority
|
63
|
1, 2, 3 .. 127
|
NODE.osi.subnet.ctc.ESH
|
10 (sec)
|
10, 20, 30 .. 1000
|
NODE.osi.subnet.ctc.GCCISISCost
|
60
|
1, 2, 3 .. 63
|
NODE.osi.subnet.ctc.IIH
|
3 (sec)
|
1, 2, 3 .. 600
|
NODE.osi.subnet.ctc.ISH
|
10 (sec)
|
10, 20, 30 .. 1000
|
NODE.osi.subnet.ctc.LANISISCost
|
20
|
1, 2, 3 .. 63
|
NODE.osi.subnet.ctc.LDCCISISCost
|
40
|
1, 2, 3 .. 63
|
NODE.osi.subnet.ctc.OSCISISCost
|
60
|
1, 2, 3 .. 63
|
NODE.osi.subnet.ctc.SDCCISISCost
|
60
|
1, 2, 3 .. 63
|
NODE.osi.tarp.L1DataCache
|
TRUE
|
FALSE, TRUE
|
NODE.osi.tarp.L2DataCache
|
FALSE
|
FALSE, TRUE
|
NODE.osi.tarp.LANStormSuppression
|
TRUE
|
FALSE, TRUE
|
NODE.osi.tarp.LDB
|
TRUE
|
FALSE, TRUE
|
NODE.osi.tarp.LDBEntry
|
5 (min)
|
1-10
|
NODE.osi.tarp.LDBFlush
|
5 (sec)
|
0-1440
|
NODE.osi.tarp.PDUsL1Propagation
|
TRUE
|
FALSE, TRUE
|
NODE.osi.tarp.PDUsL2Propagation
|
TRUE
|
FALSE, TRUE
|
NODE.osi.tarp.PDUsOrigination
|
TRUE
|
FALSE, TRUE
|
NODE.osi.tarp.T1Timer
|
15 (sec)
|
0-3600
|
NODE.osi.tarp.T2Timer
|
25 (sec)
|
0-3600
|
NODE.osi.tarp.T3Timer
|
40 (sec)
|
0-3600
|
NODE.osi.tarp.T4Timer
|
20 (sec)
|
0-3600
|
NODE.osi.tarp.Type4PDUDelay
|
0 (sec)
|
0-255
|
NODE.powerMonitor.EHIBATVG
|
-56.5 (Vdc)
|
-54.0, -54.5, -55.0, -55.5, -56.0, -56.5
|
NODE.powerMonitor.ELWBATVG
|
-40.5 (Vdc)
|
-40.5, -41.0, -41.5, -42.0, -42.5, -43.0, -43.5, -44.0
|
NODE.powerMonitor.HIBATVG
|
-54.0 (Vdc)
|
-44.0, -44.5, -45.0 .. -56.5
|
NODE.powerMonitor.LWBATVG
|
-44.0 (Vdc)
|
-40.5, -41.0, -41.5 .. -54.0
|
NODE.protection.1+1.BidirectionalSwitching
|
FALSE
|
TRUE, FALSE
|
NODE.protection.1+1.DetectionGuardTimer
|
1 (seconds)
|
0, 0.05, 0.1, 0.5, 1, 2, 3, 4, 5
|
NODE.protection.1+1.RecoveryGuardTimer
|
1 (seconds)
|
0, 0.05, 0.1 .. 10
|
NODE.protection.1+1.ReversionTime
|
5.0 (minutes)
|
0.5, 1.0, 1.5 .. 12.0
|
NODE.protection.1+1.Revertive
|
FALSE
|
TRUE, FALSE
|
NODE.protection.1+1.VerifyGuardTimer
|
0.5 (seconds)
|
0.5, 1
|
NODE.protection.blsr.RingReversionTime
|
5.0 (minutes)
|
0.5, 1.0, 1.5 .. 12.0
|
NODE.protection.blsr.RingRevertive
|
TRUE
|
TRUE, FALSE
|
NODE.protection.blsr.SpanReversionTime
|
5.0 (minutes)
|
0.5, 1.0, 1.5 .. 12.0
|
NODE.protection.blsr.SpanRevertive
|
TRUE
|
TRUE, FALSE
|
NODE.protection.splitter.ReversionTime
|
5.0 (minutes)
|
0.5, 1.0, 1.5 .. 12.0
|
NODE.protection.splitter.Revertive
|
FALSE
|
TRUE, FALSE
|
NODE.protection.ycable.ReversionTime
|
5.0 (minutes)
|
0.5, 1.0, 1.5 .. 12.0
|
NODE.protection.ycable.Revertive
|
FALSE
|
TRUE, FALSE
|
NODE.security.dataComm.ctc.DefaultTCCEthernetIP
|
10.0.0.1
|
IP Address
|
NODE.security.dataComm.ctc.DefaultTCCEthernetIPNetmask
|
24 (bits)
|
8, 9, 10 .. 32
|
NODE.security.dataComm.CtcBackplaneIpDisplaySuppression
|
(NOT SUPPORTED)
|
•FALSE, TRUE when isSecureModeSupportedOnControlCard is TRUE
•(NOT SUPPORTED) when isSecureModeSupportedOnControlCard is FALSE
|
NODE.security.dataComm.isSecureModeSupportedOnControlCard
|
FALSE
|
FALSE, TRUE
|
NODE.security.dataComm.LcdBackplaneIpSetting
|
(NOT SUPPORTED)
|
•Allow Configuration, Display Only, Suppress Display when isSecureModeSupportedOnControlCard is TRUE
•(NOT SUPPORTED) when isSecureModeSupportedOnControlCard is FALSE
|
NODE.security.dataComm.SecureModeLocked
|
(NOT SUPPORTED)
|
•FALSE, TRUE when isSecureModeSupportedOnControlCard is TRUE
•(NOT SUPPORTED) when isSecureModeSupportedOnControlCard is FALSE
|
NODE.security.dataComm.SecureModeOn (May reboot node)
|
(NOT SUPPORTED)
|
•FALSE, TRUE when isSecureModeSupportedOnControlCard is TRUE
•(NOT SUPPORTED) when isSecureModeSupportedOnControlCard is FALSE
|
NODE.security.emsAccess.AccessState
|
NonSecure
|
NonSecure, Secure
|
NODE.security.emsAccess.IIOPListenerPort (May reboot node)
|
57790 (port #)
|
0-65535
|
NODE.security.idleUserTimeout.Maintenance
|
01:00 (hours:mins)
|
00:00, 00:01, 00:02 .. 16:39
|
NODE.security.idleUserTimeout.Provisioning
|
00:30 (hours:mins)
|
00:00, 00:01, 00:02 .. 16:39
|
NODE.security.idleUserTimeout.Retrieve
|
00:00 (hours:mins)
|
00:00, 00:01, 00:02 .. 16:39
|
NODE.security.idleUserTimeout.Superuser
|
00:15 (hours:mins)
|
00:00, 00:01, 00:02 .. 16:39
|
NODE.security.lanAccess.LANAccess (May disconnect CTC from node)
|
Front & Backplane
|
No LAN Access, Front Only, Backplane Only, Front & Backplane
|
NODE.security.lanAccess.RestoreTimeout
|
5 (minutes)
|
0-60
|
NODE.security.legalDisclaimer.LoginWarningMessage
|
<html><center><b>WARNING</b></center>This system is restricted to authorized users for business purposes. Unauthorized<p>access is a violation of the law. This service may be monitored for administrative<p>and security reasons. By proceeding, you consent to this monitoring.
|
Free form field
|
NODE.security.other.DisableInactiveUser
|
FALSE
|
FALSE, TRUE
|
NODE.security.other.InactiveDuration
|
45 (days)
|
•1, 2, 3 .. 99 when DisableInactiveUser is TRUE
•45 (and N/A) when DisableInactiveUser is FALSE
|
NODE.security.other.PMClearingPrivilege
|
Provisioning
|
Provisioning, Superuser
|
NODE.security.other.SingleSessionPerUser
|
FALSE
|
TRUE, FALSE
|
NODE.security.passwordAging.EnforcePasswordAging
|
FALSE
|
TRUE, FALSE
|
NODE.security.passwordAging.maintenance.AgingPeriod
|
45 (days)
|
20-90
|
NODE.security.passwordAging.maintenance.WarningPeriod
|
5 (days)
|
2-20
|
NODE.security.passwordAging.provisioning.AgingPeriod
|
45 (days)
|
20-90
|
NODE.security.passwordAging.provisioning.WarningPeriod
|
5 (days)
|
2-20
|
NODE.security.passwordAging.retrieve.AgingPeriod
|
45 (days)
|
20-90
|
NODE.security.passwordAging.retrieve.WarningPeriod
|
5 (days)
|
2-20
|
NODE.security.passwordAging.superuser.AgingPeriod
|
45 (days)
|
20-90
|
NODE.security.passwordAging.superuser.WarningPeriod
|
5 (days)
|
2-20
|
NODE.security.passwordChange.CannotChangeNewPassword
|
FALSE
|
TRUE, FALSE
|
NODE.security.passwordChange.CannotChangeNewPasswordForNDays
|
20 (days)
|
20-95
|
NODE.security.passwordChange.NewPasswordMustDifferFromOldByNCharacters
|
1 (characters)
|
1-20
|
NODE.security.passwordChange.PreventReusingLastNPasswords
|
1 (times)
|
1-10
|
NODE.security.passwordChange.RequirePasswordChangeOnFirstLoginToNewAccount
|
FALSE
|
TRUE, FALSE
|
NODE.security.radiusServer.ctc.AccountingPort
|
1813 (port)
|
0-32767
|
NODE.security.radiusServer.ctc.AuthenticationPort
|
1812 (port)
|
0-32767
|
NODE.security.radiusServer.EnableNodeAsFinalAuthenticatorWhenAuthenticationEnabled
|
TRUE
|
FALSE, TRUE
|
NODE.security.serialCraftAccess.EnableCraftPort
|
TRUE
|
TRUE, FALSE
|
NODE.security.shellAccess.AccessState
|
NonSecure
|
Disabled, NonSecure, Secure
|
NODE.security.shellAccess.EnableShellPassword
|
FALSE
|
TRUE, FALSE
|
NODE.security.shellAccess.TelnetPort
|
23
|
23-9999
|
NODE.security.snmpAccess.AccessState
|
NonSecure
|
Disabled, NonSecure
|
NODE.security.tl1Access.AccessState
|
NonSecure
|
Disabled, NonSecure, Secure
|
NODE.security.userLockout.FailedLoginsAllowedBeforeLockout
|
5 (times)
|
0-10
|
NODE.security.userLockout.LockoutDuration
|
00:30 (mins:secs)
|
00:00, 00:05, 00:10 .. 10:00
|
NODE.security.userLockout.ManualUnlockBySuperuser
|
FALSE
|
TRUE, FALSE
|
NODE.timing.bits-1.AdminSSMIn
|
STU
|
PRS, STU, ST2, TNC, ST3E, ST3, SMC, ST4, DUS, RES
|
NODE.timing.bits-1.AISThreshold
|
SMC
|
PRS, STU, ST2, TNC, ST3E, ST3, SMC, ST4, DUS, RES
|
NODE.timing.bits-1.Coding
|
B8ZS
|
•B8ZS, AMI when FacilityType is DS1
•AMI when FacilityType is 64kHz+8kHz
|
NODE.timing.bits-1.CodingOut
|
B8ZS
|
•B8ZS, AMI when FacilityTypeOut is DS1
•AMI when FacilityTypeOut is 6MHz
|
NODE.timing.bits-1.FacilityType
|
DS1
|
DS1, 64kHz+8kHz
|
NODE.timing.bits-1.FacilityTypeOut
|
DS1
|
DS1, 6MHz
|
NODE.timing.bits-1.Framing
|
ESF
|
•ESF, D4 when FacilityType is DS1
•N/A when FacilityType is 64kHz+8kHz
|
NODE.timing.bits-1.FramingOut
|
ESF
|
•ESF, D4 when FacilityTypeOut is DS1
•N/A when FacilityTypeOut is 6MHz
|
NODE.timing.bits-1.LBO
|
0-133
|
0-133, 134-266, 267-399, 400-533, 534-655
|
NODE.timing.bits-1.State
|
IS
|
IS, OOS,DSBLD
|
NODE.timing.bits-1.StateOut
|
IS
|
IS, OOS,DSBLD
|
NODE.timing.bits-2.AdminSSMIn
|
STU
|
PRS, STU, ST2, TNC, ST3E, ST3, SMC, ST4, DUS, RES
|
NODE.timing.bits-2.AISThreshold
|
SMC
|
PRS, STU, ST2, TNC, ST3E, ST3, SMC, ST4, DUS, RES
|
NODE.timing.bits-2.Coding
|
B8ZS
|
•B8ZS, AMI when FacilityType is DS1
•AMI when FacilityType is 64kHz+8kHz
|
NODE.timing.bits-2.CodingOut
|
B8ZS
|
•B8ZS, AMI when FacilityTypeOut is DS1
•AMI when FacilityTypeOut is 6MHz
|
NODE.timing.bits-2.FacilityType
|
DS1
|
DS1, 64kHz+8kHz
|
NODE.timing.bits-2.FacilityTypeOut
|
DS1
|
DS1, 6MHz
|
NODE.timing.bits-2.Framing
|
ESF
|
•ESF, D4 when FacilityType is DS1
•N/A when FacilityType is 64kHz+8kHz
|
NODE.timing.bits-2.FramingOut
|
ESF
|
•ESF, D4 when FacilityTypeOut is DS1;
•N/A when FacilityTypeOut is 6MHz
|
NODE.timing.bits-2.LBO
|
0-133
|
0-133, 134-266, 267-399, 400-533, 534-655
|
NODE.timing.bits-2.State
|
IS
|
IS, OOS,DSBLD
|
NODE.timing.bits-2.StateOut
|
IS
|
IS, OOS,DSBLD
|
NODE.timing.general.Mode
|
External
|
External, Line, Mixed
|
NODE.timing.general.QualityOfRES
|
RES=DUS
|
•PRS<RES, STU<RES<PRS, ST2<RES<STU, ST3<RES<ST2, SMC<RES<ST3, ST4<RES<SMC, RES<ST4, RES=DUS when SSMMessageSet is Generation 1
•PRS<RES, STU<RES<PRS, ST2<RES<STU, TNC<RES<ST2, ST3E<RES<TNC, ST3<RES<ST3E, SMC<RES<ST3, ST4<RES<SMC, RES<ST4, RES=DUS when SSMMessageSet is Generation 2
|
NODE.timing.general.ReversionTime
|
5.0 (minutes)
|
0.5, 1.0, 1.5 .. 12.0
|
NODE.timing.general.Revertive
|
FALSE
|
TRUE, FALSE
|
NODE.timing.general.SSMMessageSet
|
Generation 1
|
Generation 1, Generation 2
|
D.2.3 ANSI CTC Default Settings
Table D-12 lists the CTC-level default settings for the Cisco ONS 15454. Cisco provides the following types of user-configurable defaults for CTC.
•Create circuits with the Route Automatically check box selected by default.
•Create TL1-like circuits—Instructs the node to create only cross-connects, allowing the resulting circuits to be in an upgradable state.
•Choose a default network map (which country).
Table D-12 CTC default settings (ANSI)
Default Name
|
Default Value
|
Default Domain
|
CTC.circuits.AutoRoute
|
TRUE
|
TRUE, FALSE
|
CTC.circuits.CreateLikeTL1
|
FALSE
|
TRUE, FALSE
|
CTC.network.Map
|
United States
|
-none-, Germany, Japan, Netherlands, South Korea, United Kingdom, United States
|
D.3 ETSI Platform Defaults
The following sections give the NE defaults for the 15454 ETSI platform. To see defaults for the 15454 ANSI platform, see the "ANSI Platform Defaults" section.
D.3.1 ETSI Card Default Settings
The tables in this section list the default settings for each DWDM, TXP, and MXP card. For all other cards, including optical, electrical, Ethernet, and Fibre Channel, refer to the Cisco ONS 15454 SDH Reference Manual.
Cisco provides user-configurable defaults for the Cisco ONS 15454 cards, including:
•Soak Time—All cards. The length of time that elapses between an AINS port receiving a valid signal and when it automatically changes to in-service status.
•Port State (config state)—All cards. Sets the port to one of the five available administrative states (unlocked; locked,disabled; locked,maintenance; unlocked,automaticInService), depending on whether you need ports in or out of service.
•SF BER Level—TXP and MXP cards. Defines the signal fail bit error rate.
•SD BER Level—TXP and MXP cards. Defines the signal degrade bit error rate.
•Enable Sync Messages—MXP cards. Enables synchronization status messages (S1 byte), which allow the node to choose the best timing source.
•Send Do Not Use—TXP and MXP cards. Sends a DUS message on the S1 byte when enabled.
•Payload Type—TXP and MXP cards. Defines the type of client signal.
•Termination Mode—TXP and MXP cards. Defines the type of termination (line, section, or transparent).
•ALS Mode—TXP and MXP cards. Sets the automatic laser shutdown feature to one of four available states (disabled, auto restart, manual restart, manual restart for test).
•ALS Recovery Interval—TXP and MXP cards. Sets the automatic laser shutdown recovery time interval.
•ALS Recovery Pulse Width—TXP and MXP cards. Sets the automatic laser shutdown recovery pulse signal width.
•FEC—TXP and MXP cards. Enables or disables the FEC monitoring on the optical transport network.
•G.709 OTN—TXP and MXP cards. Enables or disables the ITU-T G.709 monitoring on the optical transport network.
•FEC Thresholds—TXP and MXP cards. Set the performance monitoring parameters for gathering FEC performance data and detecting problems early.
•Optical Thresholds—TXP and MXP cards. Set the performance monitoring parameters for gathering physical optics performance data and detecting problems early.
•OTN Thresholds—TXP and MXP cards. Set the performance monitoring parameters for gathering OTN trunk-side performance data and detecting problems early.
•PM Threshold settings—All cards. Set the performance monitoring parameters for gathering performance data and detecting problems early.
Note For more information about each individual card setting, see "Change DWDM Card Settings."
Note For more information about the performance monitoring parameters, see the Chapter 9, "Monitor Performance."
D.3.1.1 MXP_2.5G_10G Card Default Settings
Table D-13 lists the MXP_2.5G_10G card default settings.
Table D-13 MXP_2.5G_10G Card Default Settings (ETSI)
Default Name
|
Default Value
|
Default Domain
|
MXP-2_5G-10G.config.client.AINSSoakTime
|
08:00 (hours:mins)
|
00:00, 00:15, 00:30 .. 48:00
|
MXP-2_5G-10G.config.client.AlsMode
|
Disabled
|
Disabled, Auto Restart, Manual Restart, Manual Restart for Test
|
MXP-2_5G-10G.config.client.AlsRecoveryPulseDuration
|
4.0 (seconds)
|
•2.0, 2.1, 2.2 .. 100.0 when AlsMode is Disabled, Auto Restart, Manual Restart
•80.0, 80.1, 80.2 .. 100.0 when AlsMode is Manual Restart for Test
|
MXP-2_5G-10G.config.client.AlsRecoveryPulseInterval
|
100 (seconds)
|
60-300
|
MXP-2_5G-10G.config.client.ppmPortAssignment
|
STM16_PORT
|
UNASSIGNED, STM16_PORT
|
MXP-2_5G-10G.config.client.ppmSlotAssignment
|
UNASSIGNED
|
UNASSIGNED, PPM (1 Port)
|
MXP-2_5G-10G.config.client.SDBER
|
1E-7
|
1E-5, 1E-6, 1E-7, 1E-8, 1E-9
|
MXP-2_5G-10G.config.client.SendDoNotUse
|
FALSE
|
TRUE, FALSE
|
MXP-2_5G-10G.config.client.SFBER
|
1E-4
|
1E-3, 1E-4, 1E-5
|
MXP-2_5G-10G.config.client.SyncMsgIn
|
TRUE
|
FALSE, TRUE
|
MXP-2_5G-10G.config.client.TerminationMode
|
Transparent
|
Transparent, Multiplex Section
|
MXP-2_5G-10G.config.trunk.AINSSoakTime
|
08:00 (hours:mins)
|
00:00, 00:15, 00:30 .. 48:00
|
MXP-2_5G-10G.config.trunk.AlsMode
|
Disabled
|
Disabled, Auto Restart, Manual Restart, Manual Restart for Test
|
MXP-2_5G-10G.config.trunk.AlsRecoveryPulseDuration
|
4.0 (seconds)
|
•2.0, 2.1, 2.2 .. 100.0 when AlsMode is Disabled, Auto Restart, Manual Restart
•80.0, 80.1, 80.2 .. 100.0 when AlsMode is Manual Restart for Test
|
MXP-2_5G-10G.config.trunk.AlsRecoveryPulseInterval
|
100 (seconds)
|
60-300
|
MXP-2_5G-10G.opticalthresholds.client.alarm.HighLaserBias
|
90.0 (%)
|
0.0, 0.1, 0.2 .. 100.0
|
MXP-2_5G-10G.opticalthresholds.client.alarm.HighRxPower
|
3.0 (dBm)
|
LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0
|
MXP-2_5G-10G.opticalthresholds.client.alarm.HighTxPower
|
3.0 (dBm)
|
LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0
|
MXP-2_5G-10G.opticalthresholds.client.alarm.LowRxPower
|
-21.0 (dBm)
|
-40.0, -39.9, -39.8 .. HighRxPower
|
MXP-2_5G-10G.opticalthresholds.client.alarm.LowTxPower
|
-8.0 (dBm)
|
-40.0, -39.9, -39.8 .. HighTxPower
|
MXP-2_5G-10G.opticalthresholds.client.warning.15min.HighLaserBias
|
81.0 (%)
|
0.0, 0.1, 0.2 .. 100.0
|
MXP-2_5G-10G.opticalthresholds.client.warning.15min.HighRxPower
|
2.0 (dBm)
|
LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0
|
MXP-2_5G-10G.opticalthresholds.client.warning.15min.HighTxPower
|
2.0 (dBm)
|
LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0
|
MXP-2_5G-10G.opticalthresholds.client.warning.15min.LowRxPower
|
-20.0 (dBm)
|
-40.0, -39.9, -39.8 .. HighRxPower
|
MXP-2_5G-10G.opticalthresholds.client.warning.15min.LowTxPower
|
-7.0 (dBm)
|
-40.0, -39.9, -39.8 .. HighTxPower
|
MXP-2_5G-10G.opticalthresholds.client.warning.1day.HighLaserBias
|
85.5 (%)
|
0.0, 0.1, 0.2 .. 100.0
|
MXP-2_5G-10G.opticalthresholds.client.warning.1day.HighRxPower
|
2.5 (dBm)
|
LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0
|
MXP-2_5G-10G.opticalthresholds.client.warning.1day.HighTxPower
|
2.5 (dBm)
|
LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0
|
MXP-2_5G-10G.opticalthresholds.client.warning.1day.LowRxPower
|
-20.5 (dBm)
|
-40.0, -39.9, -39.8 .. HighRxPower
|
MXP-2_5G-10G.opticalthresholds.client.warning.1day.LowTxPower
|
-7.5 (dBm)
|
-40.0, -39.9, -39.8 .. HighTxPower
|
MXP-2_5G-10G.opticalthresholds.trunk.alarm.HighLaserBias
|
90.0 (%)
|
0.0, 0.1, 0.2 .. 100.0
|
MXP-2_5G-10G.opticalthresholds.trunk.alarm.HighRxPower
|
-8.0 (dBm)
|
LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0
|
MXP-2_5G-10G.opticalthresholds.trunk.alarm.HighTxPower
|
4.0 (dBm)
|
LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0
|
MXP-2_5G-10G.opticalthresholds.trunk.alarm.LowRxPower
|
-25.0 (dBm)
|
-40.0, -39.9, -39.8 .. HighRxPower
|
MXP-2_5G-10G.opticalthresholds.trunk.alarm.LowTxPower
|
2.0 (dBm)
|
-40.0, -39.9, -39.8 .. HighTxPower
|
MXP-2_5G-10G.opticalthresholds.trunk.warning.15min.HighLaserBias
|
81.0 (%)
|
0.0, 0.1, 0.2 .. 100.0
|
MXP-2_5G-10G.opticalthresholds.trunk.warning.15min.HighRxPower
|
-7.5 (dBm)
|
LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0
|
MXP-2_5G-10G.opticalthresholds.trunk.warning.15min.HighTxPower
|
3.5 (dBm)
|
LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0
|
MXP-2_5G-10G.opticalthresholds.trunk.warning.15min.LowRxPower
|
-24.5 (dBm)
|
-40.0, -39.9, -39.8 .. HighRxPower
|
MXP-2_5G-10G.opticalthresholds.trunk.warning.15min.LowTxPower
|
2.5 (dBm)
|
-40.0, -39.9, -39.8 .. HighTxPower
|
MXP-2_5G-10G.opticalthresholds.trunk.warning.1day.HighLaserBias
|
85.5 (%)
|
0.0, 0.1, 0.2 .. 100.0
|
MXP-2_5G-10G.opticalthresholds.trunk.warning.1day.HighRxPower
|
-7.3 (dBm)
|
LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0
|
MXP-2_5G-10G.opticalthresholds.trunk.warning.1day.HighTxPower
|
3.7 (dBm)
|
LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0
|
MXP-2_5G-10G.opticalthresholds.trunk.warning.1day.LowRxPower
|
-24.7 (dBm)
|
-40.0, -39.9, -39.8 .. HighRxPower
|
MXP-2_5G-10G.opticalthresholds.trunk.warning.1day.LowTxPower
|
2.3 (dBm)
|
-40.0, -39.9, -39.8 .. HighTxPower
|
MXP-2_5G-10G.otn.fecthresholds.standard.15min.BitErrorsCorrected
|
903330 (count)
|
0-9033621811200
|
MXP-2_5G-10G.otn.fecthresholds.standard.15min.UncorrectableWords
|
5 (count)
|
0-4724697600
|
MXP-2_5G-10G.otn.fecthresholds.standard.1day.BitErrorsCorrected
|
86719680 (count)
|
0-867227693875200
|
MXP-2_5G-10G.otn.fecthresholds.standard.1day.UncorrectableWords
|
480 (count)
|
0-453570969600
|
MXP-2_5G-10G.otn.g709thresholds.pm.farend.15min.BBE
|
85040 (count)
|
0-8850600
|
MXP-2_5G-10G.otn.g709thresholds.pm.farend.15min.ES
|
87 (seconds)
|
0-900
|
MXP-2_5G-10G.otn.g709thresholds.pm.farend.15min.FC
|
10 (count)
|
0-72
|
MXP-2_5G-10G.otn.g709thresholds.pm.farend.15min.SES
|
1 (seconds)
|
0-900
|
MXP-2_5G-10G.otn.g709thresholds.pm.farend.15min.UAS
|
3 (seconds)
|
0-900
|
MXP-2_5G-10G.otn.g709thresholds.pm.farend.1day.BBE
|
850400 (count)
|
0-849657600
|
MXP-2_5G-10G.otn.g709thresholds.pm.farend.1day.ES
|
864 (seconds)
|
0-86400
|
MXP-2_5G-10G.otn.g709thresholds.pm.farend.1day.FC
|
40 (count)
|
0-6912
|
MXP-2_5G-10G.otn.g709thresholds.pm.farend.1day.SES
|
4 (seconds)
|
0-86400
|
MXP-2_5G-10G.otn.g709thresholds.pm.farend.1day.UAS
|
10 (seconds)
|
0-86400
|
MXP-2_5G-10G.otn.g709thresholds.pm.nearend.15min.BBE
|
85040 (count)
|
0-8850600
|
MXP-2_5G-10G.otn.g709thresholds.pm.nearend.15min.ES
|
87 (seconds)
|
0-900
|
MXP-2_5G-10G.otn.g709thresholds.pm.nearend.15min.FC
|
10 (count)
|
0-72
|
MXP-2_5G-10G.otn.g709thresholds.pm.nearend.15min.SES
|
1 (seconds)
|
0-900
|
MXP-2_5G-10G.otn.g709thresholds.pm.nearend.15min.UAS
|
3 (seconds)
|
0-900
|
MXP-2_5G-10G.otn.g709thresholds.pm.nearend.1day.BBE
|
850400 (count)
|
0-849657600
|
MXP-2_5G-10G.otn.g709thresholds.pm.nearend.1day.ES
|
864 (seconds)
|
0-86400
|
MXP-2_5G-10G.otn.g709thresholds.pm.nearend.1day.FC
|
40 (count)
|
0-6912
|
MXP-2_5G-10G.otn.g709thresholds.pm.nearend.1day.SES
|
4 (seconds)
|
0-86400
|
MXP-2_5G-10G.otn.g709thresholds.pm.nearend.1day.UAS
|
10 (seconds)
|
0-86400
|
MXP-2_5G-10G.otn.g709thresholds.sm.farend.15min.BBE
|
10000 (count)
|
0-8850600
|
MXP-2_5G-10G.otn.g709thresholds.sm.farend.15min.ES
|
500 (seconds)
|
0-900
|
MXP-2_5G-10G.otn.g709thresholds.sm.farend.15min.FC
|
10 (count)
|
0-72
|
MXP-2_5G-10G.otn.g709thresholds.sm.farend.15min.SES
|
500 (seconds)
|
0-900
|
MXP-2_5G-10G.otn.g709thresholds.sm.farend.15min.UAS
|
500 (seconds)
|
0-900
|
MXP-2_5G-10G.otn.g709thresholds.sm.farend.1day.BBE
|
100000 (count)
|
0-849657600
|
MXP-2_5G-10G.otn.g709thresholds.sm.farend.1day.ES
|
5000 (seconds)
|
0-86400
|
MXP-2_5G-10G.otn.g709thresholds.sm.farend.1day.FC
|
40 (count)
|
0-6912
|
MXP-2_5G-10G.otn.g709thresholds.sm.farend.1day.SES
|
5000 (seconds)
|
0-86400
|
MXP-2_5G-10G.otn.g709thresholds.sm.farend.1day.UAS
|
5000 (seconds)
|
0-86400
|
MXP-2_5G-10G.otn.g709thresholds.sm.nearend.15min.BBE
|
10000 (count)
|
0-8850600
|
MXP-2_5G-10G.otn.g709thresholds.sm.nearend.15min.ES
|
500 (seconds)
|
0-900
|
MXP-2_5G-10G.otn.g709thresholds.sm.nearend.15min.FC
|
10 (count)
|
0-72
|
MXP-2_5G-10G.otn.g709thresholds.sm.nearend.15min.SES
|
500 (seconds)
|
0-900
|
MXP-2_5G-10G.otn.g709thresholds.sm.nearend.15min.UAS
|
500 (seconds)
|
0-900
|
MXP-2_5G-10G.otn.g709thresholds.sm.nearend.1day.BBE
|
100000 (count)
|
0-849657600
|
MXP-2_5G-10G.otn.g709thresholds.sm.nearend.1day.ES
|
5000 (seconds)
|
0-86400
|
MXP-2_5G-10G.otn.g709thresholds.sm.nearend.1day.FC
|
40 (count)
|
0-6912
|
MXP-2_5G-10G.otn.g709thresholds.sm.nearend.1day.SES
|
5000 (seconds)
|
0-86400
|
MXP-2_5G-10G.otn.g709thresholds.sm.nearend.1day.UAS
|
5000 (seconds)
|
0-86400
|
MXP-2_5G-10G.otn.otnLines.FEC
|
Standard
|
•Disable, Standard, Enhanced when G709OTN is Enable
•Disable when G709OTN is Disable
|
MXP-2_5G-10G.otn.otnLines.G709OTN
|
Enable
|
Disable, Enable
|
MXP-2_5G-10G.otn.otnLines.SDBER
|
1E-7
|
1E-5, 1E-6, 1E-7, 1E-8, 1E-9
|
MXP-2_5G-10G.pmthresholds.client.ms.farend.15min.BBE
|
21260 (count)
|
0-2212200
|
MXP-2_5G-10G.pmthresholds.client.ms.farend.15min.EB
|
21260 (count)
|
0-2212200
|
MXP-2_5G-10G.pmthresholds.client.ms.farend.15min.ES
|
87 (seconds)
|
0-900
|
MXP-2_5G-10G.pmthresholds.client.ms.farend.15min.SES
|
1 (seconds)
|
0-900
|
MXP-2_5G-10G.pmthresholds.client.ms.farend.15min.UAS
|
3 (seconds)
|
0-900
|
MXP-2_5G-10G.pmthresholds.client.ms.farend.1day.BBE
|
212600 (count)
|
0-212371200
|
MXP-2_5G-10G.pmthresholds.client.ms.farend.1day.EB
|
212600 (count)
|
0-212371200
|
MXP-2_5G-10G.pmthresholds.client.ms.farend.1day.ES
|
864 (seconds)
|
0-86400
|
MXP-2_5G-10G.pmthresholds.client.ms.farend.1day.SES
|
4 (seconds)
|
0-86400
|
MXP-2_5G-10G.pmthresholds.client.ms.farend.1day.UAS
|
10 (seconds)
|
0-86400
|
MXP-2_5G-10G.pmthresholds.client.ms.nearend.15min.BBE
|
21260 (count)
|
0-2212200
|
MXP-2_5G-10G.pmthresholds.client.ms.nearend.15min.EB
|
21260 (count)
|
0-2212200
|
MXP-2_5G-10G.pmthresholds.client.ms.nearend.15min.ES
|
87 (seconds)
|
0-900
|
MXP-2_5G-10G.pmthresholds.client.ms.nearend.15min.SES
|
1 (seconds)
|
0-900
|
MXP-2_5G-10G.pmthresholds.client.ms.nearend.15min.UAS
|
3 (seconds)
|
0-900
|
MXP-2_5G-10G.pmthresholds.client.ms.nearend.1day.BBE
|
212600 (count)
|
0-212371200
|
MXP-2_5G-10G.pmthresholds.client.ms.nearend.1day.EB
|
212600 (count)
|
0-212371200
|
MXP-2_5G-10G.pmthresholds.client.ms.nearend.1day.ES
|
864 (seconds)
|
0-86400
|
MXP-2_5G-10G.pmthresholds.client.ms.nearend.1day.SES
|
4 (seconds)
|
0-86400
|
MXP-2_5G-10G.pmthresholds.client.ms.nearend.1day.UAS
|
10 (seconds)
|
0-86400
|
MXP-2_5G-10G.pmthresholds.client.rs.nearend.15min.BBE
|
10000 (count)
|
0-2212200
|
MXP-2_5G-10G.pmthresholds.client.rs.nearend.15min.EB
|
10000 (count)
|
0-2151900
|
MXP-2_5G-10G.pmthresholds.client.rs.nearend.15min.ES
|
500 (seconds)
|
0-900
|
MXP-2_5G-10G.pmthresholds.client.rs.nearend.15min.SES
|
500 (seconds)
|
0-900
|
MXP-2_5G-10G.pmthresholds.client.rs.nearend.15min.UAS
|
3 (seconds)
|
0-900
|
MXP-2_5G-10G.pmthresholds.client.rs.nearend.1day.BBE
|
100000 (count)
|
0-212371200
|
MXP-2_5G-10G.pmthresholds.client.rs.nearend.1day.EB
|
100000 (count)
|
0-206582400
|
MXP-2_5G-10G.pmthresholds.client.rs.nearend.1day.ES
|
5000 (seconds)
|
0-86400
|
MXP-2_5G-10G.pmthresholds.client.rs.nearend.1day.SES
|
5000 (seconds)
|
0-86400
|
MXP-2_5G-10G.pmthresholds.client.rs.nearend.1day.UAS
|
10 (seconds)
|
0-86400
|
MXP-2_5G-10G.pmthresholds.trunk.ms.farend.15min.BBE
|
85040 (count)
|
0-8850600
|
MXP-2_5G-10G.pmthresholds.trunk.ms.farend.15min.EB
|
85040 (count)
|
0-8850600
|
MXP-2_5G-10G.pmthresholds.trunk.ms.farend.15min.ES
|
87 (seconds)
|
0-900
|
MXP-2_5G-10G.pmthresholds.trunk.ms.farend.15min.SES
|
1 (seconds)
|
0-900
|
MXP-2_5G-10G.pmthresholds.trunk.ms.farend.15min.UAS
|
3 (seconds)
|
0-900
|
MXP-2_5G-10G.pmthresholds.trunk.ms.farend.1day.BBE
|
850400 (count)
|
0-849657600
|
MXP-2_5G-10G.pmthresholds.trunk.ms.farend.1day.EB
|
850400 (count)
|
0-849657600
|
MXP-2_5G-10G.pmthresholds.trunk.ms.farend.1day.ES
|
864 (seconds)
|
0-86400
|
MXP-2_5G-10G.pmthresholds.trunk.ms.farend.1day.SES
|
4 (seconds)
|
0-86400
|
MXP-2_5G-10G.pmthresholds.trunk.ms.farend.1day.UAS
|
10 (seconds)
|
0-86400
|
MXP-2_5G-10G.pmthresholds.trunk.ms.nearend.15min.BBE
|
85040 (count)
|
0-8850600
|
MXP-2_5G-10G.pmthresholds.trunk.ms.nearend.15min.EB
|
85040 (count)
|
0-8850600
|
MXP-2_5G-10G.pmthresholds.trunk.ms.nearend.15min.ES
|
87 (seconds)
|
0-900
|
MXP-2_5G-10G.pmthresholds.trunk.ms.nearend.15min.SES
|
1 (seconds)
|
0-900
|
MXP-2_5G-10G.pmthresholds.trunk.ms.nearend.15min.UAS
|
3 (seconds)
|
0-900
|
MXP-2_5G-10G.pmthresholds.trunk.ms.nearend.1day.BBE
|
850400 (count)
|
0-849657600
|
MXP-2_5G-10G.pmthresholds.trunk.ms.nearend.1day.EB
|
850400 (count)
|
0-849657600
|
MXP-2_5G-10G.pmthresholds.trunk.ms.nearend.1day.ES
|
864 (seconds)
|
0-86400
|
MXP-2_5G-10G.pmthresholds.trunk.ms.nearend.1day.SES
|
4 (seconds)
|
0-86400
|
MXP-2_5G-10G.pmthresholds.trunk.ms.nearend.1day.UAS
|
10 (seconds)
|
0-86400
|
MXP-2_5G-10G.pmthresholds.trunk.rs.nearend.15min.BBE
|
10000 (count)
|
0-8850600
|
MXP-2_5G-10G.pmthresholds.trunk.rs.nearend.15min.EB
|
10000 (count)
|
0-7967700
|
MXP-2_5G-10G.pmthresholds.trunk.rs.nearend.15min.ES
|
500 (seconds)
|
0-900
|
MXP-2_5G-10G.pmthresholds.trunk.rs.nearend.15min.SES
|
500 (seconds)
|
0-900
|
MXP-2_5G-10G.pmthresholds.trunk.rs.nearend.15min.UAS
|
3 (seconds)
|
0-900
|
MXP-2_5G-10G.pmthresholds.trunk.rs.nearend.1day.BBE
|
100000 (count)
|
0-849657600
|
MXP-2_5G-10G.pmthresholds.trunk.rs.nearend.1day.EB
|
100000 (count)
|
0-764899200
|
MXP-2_5G-10G.pmthresholds.trunk.rs.nearend.1day.ES
|
5000 (seconds)
|
0-86400
|
MXP-2_5G-10G.pmthresholds.trunk.rs.nearend.1day.SES
|
5000 (seconds)
|
0-86400
|
MXP-2_5G-10G.pmthresholds.trunk.rs.nearend.1day.UAS
|
10 (seconds)
|
0-86400
|
D.3.1.2 MXP_2.5G_10E Card Default Settings
Table D-14 lists the MXP_2.5G_10E card default settings.
Table D-14 MXP_2.5G_10E Card Default Settings (ETSI)
Default Name
|
Default Value
|
Default Domain
|
MXP-2_5G-10E.config.client.AINSSoakTime
|
08:00 (hours:mins)
|
00:00, 00:15, 00:30 .. 48:00
|
MXP-2_5G-10E.config.client.AisSquelchMode
|
Squelch
|
Ais, Squelch
|
MXP-2_5G-10E.config.client.AlsMode
|
Disabled
|
Disabled, Auto Restart, Manual Restart, Manual Restart for Test
|
MXP-2_5G-10E.config.client.AlsRecoveryPulseDuration
|
2.0 (seconds)
|
•2.0, 2.1, 2.2 .. 100.0 when AlsMode is Disabled, Auto Restart, Manual Restart
•80.0, 80.1, 80.2 .. 100.0 when AlsMode is Manual Restart for Test
|
MXP-2_5G-10E.config.client.AlsRecoveryPulseInterval
|
100 (seconds)
|
100-2000
|
MXP-2_5G-10E.config.client.ppmPortAssignment
|
STM16_PORT
|
UNASSIGNED, STM16_PORT
|
MXP-2_5G-10E.config.client.ppmSlotAssignment
|
UNASSIGNED
|
UNASSIGNED, PPM (1 Port)
|
MXP-2_5G-10E.config.client.SDBER
|
1E-7
|
1E-5, 1E-6, 1E-7, 1E-8, 1E-9
|
MXP-2_5G-10E.config.client.SendDoNotUse
|
FALSE
|
TRUE, FALSE
|
MXP-2_5G-10E.config.client.SFBER
|
1E-4
|
1E-3, 1E-4, 1E-5
|
MXP-2_5G-10E.config.client.SyncMsgIn
|
TRUE
|
FALSE, TRUE
|
MXP-2_5G-10E.config.client.TerminationMode
|
Transparent
|
Transparent, Regeneration Section
|
MXP-2_5G-10E.config.trunk.AINSSoakTime
|
08:00 (hours:mins)
|
00:00, 00:15, 00:30 .. 48:00
|
MXP-2_5G-10E.config.trunk.AlsMode
|
Disabled
|
Disabled, Auto Restart, Manual Restart, Manual Restart for Test
|
MXP-2_5G-10E.config.trunk.AlsRecoveryPulseDuration
|
100.0 (seconds)
|
•60.0, 60.1, 60.2 .. 200.0 when AlsMode is Disabled, Auto Restart, Manual Restart
•80.0, 80.1, 80.2 .. 100.0 when AlsMode is Manual Restart for Test
|
MXP-2_5G-10E.config.trunk.AlsRecoveryPulseInterval
|
300 (seconds)
|
200-2000
|
MXP-2_5G-10E.opticalthresholds.client.alarm.HighLaserBias
|
90.0 (%)
|
0.0, 0.1, 0.2 .. 100.0
|
MXP-2_5G-10E.opticalthresholds.client.alarm.HighRxPower
|
3.0 (dBm)
|
-21.0, -20.9, -20.8 .. 30.0
|
MXP-2_5G-10E.opticalthresholds.client.alarm.HighTxPower
|
3.0 (dBm)
|
-8.0, -7.9, -7.8 .. 30.0
|
MXP-2_5G-10E.opticalthresholds.client.alarm.LowRxPower
|
-21.0 (dBm)
|
-40.0, -39.9, -39.8 .. 3.0
|
MXP-2_5G-10E.opticalthresholds.client.alarm.LowTxPower
|
-8.0 (dBm)
|
-40.0, -39.9, -39.8 .. 3.0
|
MXP-2_5G-10E.opticalthresholds.client.warning.15min.HighLaserBias
|
81.0 (%)
|
0.0, 0.1, 0.2 .. 100.0
|
MXP-2_5G-10E.opticalthresholds.client.warning.15min.HighRxPower
|
2.0 (dBm)
|
-20.0, -19.9, -19.8 .. 30.0
|
MXP-2_5G-10E.opticalthresholds.client.warning.15min.HighTxPower
|
2.0 (dBm)
|
-7.0, -6.9, -6.8 .. 30.0
|
MXP-2_5G-10E.opticalthresholds.client.warning.15min.LowRxPower
|
-20.0 (dBm)
|
-40.0, -39.9, -39.8 .. 2.0
|
MXP-2_5G-10E.opticalthresholds.client.warning.15min.LowTxPower
|
-7.0 (dBm)
|
-40.0, -39.9, -39.8 .. 2.0
|
MXP-2_5G-10E.opticalthresholds.client.warning.1day.HighLaserBias
|
85.5 (%)
|
0.0, 0.1, 0.2 .. 100.0
|
MXP-2_5G-10E.opticalthresholds.client.warning.1day.HighRxPower
|
2.5 (dBm)
|
-20.5, -20.4, -20.3 .. 30.0
|
MXP-2_5G-10E.opticalthresholds.client.warning.1day.HighTxPower
|
2.5 (dBm)
|
-7.5, -7.4, -7.3 .. 30.0
|
MXP-2_5G-10E.opticalthresholds.client.warning.1day.LowRxPower
|
-20.5 (dBm)
|
-40.0, -39.9, -39.8 .. 2.5
|
MXP-2_5G-10E.opticalthresholds.client.warning.1day.LowTxPower
|
-7.5 (dBm)
|
-40.0, -39.9, -39.8 .. 2.5
|
MXP-2_5G-10E.opticalthresholds.trunk.alarm.HighLaserBias
|
98.0 (%)
|
0.0, 0.1, 0.2 .. 100.0
|
MXP-2_5G-10E.opticalthresholds.trunk.alarm.HighRxPower
|
-8.0 (dBm)
|
-25.0, -24.9, -24.8 .. 30.0
|
MXP-2_5G-10E.opticalthresholds.trunk.alarm.HighTxPower
|
8.0 (dBm)
|
1.0, 1.1, 1.2 .. 30.0
|
MXP-2_5G-10E.opticalthresholds.trunk.alarm.LowRxPower
|
-25.0 (dBm)
|
-40.0, -39.9, -39.8 .. -8.0
|
MXP-2_5G-10E.opticalthresholds.trunk.alarm.LowTxPower
|
1.0 (dBm)
|
-40.0, -39.9, -39.8 .. 8.0
|
MXP-2_5G-10E.opticalthresholds.trunk.warning.15min.HighLaserBias
|
95.0 (%)
|
0.0, 0.1, 0.2 .. 100.0
|
MXP-2_5G-10E.opticalthresholds.trunk.warning.15min.HighRxPower
|
-7.5 (dBm)
|
-24.5, -24.4, -24.3 .. 30.0
|
MXP-2_5G-10E.opticalthresholds.trunk.warning.15min.HighTxPower
|
7.0 (dBm)
|
2.0, 2.1, 2.2 .. 30.0
|
MXP-2_5G-10E.opticalthresholds.trunk.warning.15min.LowRxPower
|
-24.5 (dBm)
|
-40.0, -39.9, -39.8 .. -7.5
|
MXP-2_5G-10E.opticalthresholds.trunk.warning.15min.LowTxPower
|
2.0 (dBm)
|
-40.0, -39.9, -39.8 .. 7.0
|
MXP-2_5G-10E.opticalthresholds.trunk.warning.1day.HighLaserBias
|
96.0 (%)
|
0.0, 0.1, 0.2 .. 100.0
|
MXP-2_5G-10E.opticalthresholds.trunk.warning.1day.HighRxPower
|
-7.3 (dBm)
|
-24.7, -24.6, -24.5 .. 30.0
|
MXP-2_5G-10E.opticalthresholds.trunk.warning.1day.HighTxPower
|
7.0 (dBm)
|
2.0, 2.1, 2.2 .. 30.0
|
MXP-2_5G-10E.opticalthresholds.trunk.warning.1day.LowRxPower
|
-24.7 (dBm)
|
-40.0, -39.9, -39.8 .. -7.3
|
MXP-2_5G-10E.opticalthresholds.trunk.warning.1day.LowTxPower
|
2.0 (dBm)
|
-40.0, -39.9, -39.8 .. 7.0
|
MXP-2_5G-10E.otn.fecthresholds.enhanced.15min.BitErrorsCorrected
|
903330 (count)
|
0-9033621811200
|
MXP-2_5G-10E.otn.fecthresholds.enhanced.15min.UncorrectableWords
|
5 (count)
|
0-4724697600
|
MXP-2_5G-10E.otn.fecthresholds.enhanced.1day.BitErrorsCorrected
|
86719680 (count)
|
0-867227693875200
|
MXP-2_5G-10E.otn.fecthresholds.enhanced.1day.UncorrectableWords
|
480 (count)
|
0-453570969600
|
MXP-2_5G-10E.otn.fecthresholds.standard.15min.BitErrorsCorrected
|
903330 (count)
|
0-9033621811200
|
MXP-2_5G-10E.otn.fecthresholds.standard.15min.UncorrectableWords
|
5 (count)
|
0-4724697600
|
MXP-2_5G-10E.otn.fecthresholds.standard.1day.BitErrorsCorrected
|
86719680 (count)
|
0-867227693875200
|
MXP-2_5G-10E.otn.fecthresholds.standard.1day.UncorrectableWords
|
480 (count)
|
0-453570969600
|
MXP-2_5G-10E.otn.g709thresholds.pm.farend.15min.BBE
|
85040 (count)
|
0-8850600
|
MXP-2_5G-10E.otn.g709thresholds.pm.farend.15min.ES
|
87 (seconds)
|
0-900
|
MXP-2_5G-10E.otn.g709thresholds.pm.farend.15min.FC
|
10 (count)
|
0-72
|
MXP-2_5G-10E.otn.g709thresholds.pm.farend.15min.SES
|
1 (seconds)
|
0-900
|
MXP-2_5G-10E.otn.g709thresholds.pm.farend.15min.UAS
|
3 (seconds)
|
0-900
|
MXP-2_5G-10E.otn.g709thresholds.pm.farend.1day.BBE
|
850400 (count)
|
0-849657600
|
MXP-2_5G-10E.otn.g709thresholds.pm.farend.1day.ES
|
864 (seconds)
|
0-86400
|
MXP-2_5G-10E.otn.g709thresholds.pm.farend.1day.FC
|
40 (count)
|
0-6912
|
MXP-2_5G-10E.otn.g709thresholds.pm.farend.1day.SES
|
4 (seconds)
|
0-86400
|
MXP-2_5G-10E.otn.g709thresholds.pm.farend.1day.UAS
|
10 (seconds)
|
0-86400
|
MXP-2_5G-10E.otn.g709thresholds.pm.nearend.15min.BBE
|
85040 (count)
|
0-8850600
|
MXP-2_5G-10E.otn.g709thresholds.pm.nearend.15min.ES
|
87 (seconds)
|
0-900
|
MXP-2_5G-10E.otn.g709thresholds.pm.nearend.15min.FC
|
10 (count)
|
0-72
|
MXP-2_5G-10E.otn.g709thresholds.pm.nearend.15min.SES
|
1 (seconds)
|
0-900
|
MXP-2_5G-10E.otn.g709thresholds.pm.nearend.15min.UAS
|
3 (seconds)
|
0-900
|
MXP-2_5G-10E.otn.g709thresholds.pm.nearend.1day.BBE
|
850400 (count)
|
0-849657600
|
MXP-2_5G-10E.otn.g709thresholds.pm.nearend.1day.ES
|
864 (seconds)
|
0-86400
|
MXP-2_5G-10E.otn.g709thresholds.pm.nearend.1day.FC
|
40 (count)
|
0-6912
|
MXP-2_5G-10E.otn.g709thresholds.pm.nearend.1day.SES
|
4 (seconds)
|
0-86400
|
MXP-2_5G-10E.otn.g709thresholds.pm.nearend.1day.UAS
|
10 (seconds)
|
0-86400
|
MXP-2_5G-10E.otn.g709thresholds.sm.farend.15min.BBE
|
10000 (count)
|
0-8850600
|
MXP-2_5G-10E.otn.g709thresholds.sm.farend.15min.ES
|
500 (seconds)
|
0-900
|
MXP-2_5G-10E.otn.g709thresholds.sm.farend.15min.FC
|
10 (count)
|
0-72
|
MXP-2_5G-10E.otn.g709thresholds.sm.farend.15min.SES
|
500 (seconds)
|
0-900
|
MXP-2_5G-10E.otn.g709thresholds.sm.farend.15min.UAS
|
500 (seconds)
|
0-900
|
MXP-2_5G-10E.otn.g709thresholds.sm.farend.1day.BBE
|
100000 (count)
|
0-849657600
|
MXP-2_5G-10E.otn.g709thresholds.sm.farend.1day.ES
|
5000 (seconds)
|
0-86400
|
MXP-2_5G-10E.otn.g709thresholds.sm.farend.1day.FC
|
40 (count)
|
0-6912
|
MXP-2_5G-10E.otn.g709thresholds.sm.farend.1day.SES
|
5000 (seconds)
|
0-86400
|
MXP-2_5G-10E.otn.g709thresholds.sm.farend.1day.UAS
|
5000 (seconds)
|
0-86400
|
MXP-2_5G-10E.otn.g709thresholds.sm.nearend.15min.BBE
|
10000 (count)
|
0-8850600
|
MXP-2_5G-10E.otn.g709thresholds.sm.nearend.15min.ES
|
500 (seconds)
|
0-900
|
MXP-2_5G-10E.otn.g709thresholds.sm.nearend.15min.FC
|
10 (count)
|
0-72
|
MXP-2_5G-10E.otn.g709thresholds.sm.nearend.15min.SES
|
500 (seconds)
|
0-900
|
MXP-2_5G-10E.otn.g709thresholds.sm.nearend.15min.UAS
|
500 (seconds)
|
0-900
|
MXP-2_5G-10E.otn.g709thresholds.sm.nearend.1day.BBE
|
100000 (count)
|
0-849657600
|
MXP-2_5G-10E.otn.g709thresholds.sm.nearend.1day.ES
|
5000 (seconds)
|
0-86400
|
MXP-2_5G-10E.otn.g709thresholds.sm.nearend.1day.FC
|
40 (count)
|
0-6912
|
MXP-2_5G-10E.otn.g709thresholds.sm.nearend.1day.SES
|
5000 (seconds)
|
0-86400
|
MXP-2_5G-10E.otn.g709thresholds.sm.nearend.1day.UAS
|
5000 (seconds)
|
0-86400
|
MXP-2_5G-10E.otn.otnLines.AsynchSynchMapping
|
ODU Multiplex
|
ODU Multiplex
|
MXP-2_5G-10E.otn.otnLines.FEC
|
Standard
|
Disable, Standard, Enhanced
|
MXP-2_5G-10E.otn.otnLines.G709OTN
|
Enable
|
Enable
|
MXP-2_5G-10E.otn.otnLines.SDBER
|
1E-7
|
1E-5, 1E-6, 1E-7, 1E-8, 1E-9
|
MXP-2_5G-10E.pmthresholds.client.ms.farend.15min.BBE
|
21260 (count)
|
0-2212200
|
MXP-2_5G-10E.pmthresholds.client.ms.farend.15min.EB
|
21260 (count)
|
0-2212200
|
MXP-2_5G-10E.pmthresholds.client.ms.farend.15min.ES
|
87 (seconds)
|
0-900
|
MXP-2_5G-10E.pmthresholds.client.ms.farend.15min.SES
|
1 (seconds)
|
0-900
|
MXP-2_5G-10E.pmthresholds.client.ms.farend.15min.UAS
|
3 (seconds)
|
0-900
|
MXP-2_5G-10E.pmthresholds.client.ms.farend.1day.BBE
|
212600 (count)
|
0-212371200
|
MXP-2_5G-10E.pmthresholds.client.ms.farend.1day.EB
|
212600 (count)
|
0-212371200
|
MXP-2_5G-10E.pmthresholds.client.ms.farend.1day.ES
|
864 (seconds)
|
0-86400
|
MXP-2_5G-10E.pmthresholds.client.ms.farend.1day.SES
|
4 (seconds)
|
0-86400
|
MXP-2_5G-10E.pmthresholds.client.ms.farend.1day.UAS
|
10 (seconds)
|
0-86400
|
MXP-2_5G-10E.pmthresholds.client.ms.nearend.15min.BBE
|
21260 (count)
|
0-2212200
|
MXP-2_5G-10E.pmthresholds.client.ms.nearend.15min.EB
|
21260 (count)
|
0-2212200
|
MXP-2_5G-10E.pmthresholds.client.ms.nearend.15min.ES
|
87 (seconds)
|
0-900
|
MXP-2_5G-10E.pmthresholds.client.ms.nearend.15min.SES
|
1 (seconds)
|
0-900
|
MXP-2_5G-10E.pmthresholds.client.ms.nearend.15min.UAS
|
3 (seconds)
|
0-900
|
MXP-2_5G-10E.pmthresholds.client.ms.nearend.1day.BBE
|
212600 (count)
|
0-212371200
|
MXP-2_5G-10E.pmthresholds.client.ms.nearend.1day.EB
|
212600 (count)
|
0-212371200
|
MXP-2_5G-10E.pmthresholds.client.ms.nearend.1day.ES
|
864 (seconds)
|
0-86400
|
MXP-2_5G-10E.pmthresholds.client.ms.nearend.1day.SES
|
4 (seconds)
|
0-86400
|
MXP-2_5G-10E.pmthresholds.client.ms.nearend.1day.UAS
|
10 (seconds)
|
0-86400
|
MXP-2_5G-10E.pmthresholds.client.rs.nearend.15min.BBE
|
10000 (count)
|
0-2212200
|
MXP-2_5G-10E.pmthresholds.client.rs.nearend.15min.EB
|
10000 (count)
|
0-2151900
|
MXP-2_5G-10E.pmthresholds.client.rs.nearend.15min.ES
|
500 (seconds)
|
0-900
|
MXP-2_5G-10E.pmthresholds.client.rs.nearend.15min.SES
|
500 (seconds)
|
0-900
|
MXP-2_5G-10E.pmthresholds.client.rs.nearend.15min.UAS
|
3 (seconds)
|
0-900
|
MXP-2_5G-10E.pmthresholds.client.rs.nearend.1day.BBE
|
100000 (count)
|
0-212371200
|
MXP-2_5G-10E.pmthresholds.client.rs.nearend.1day.EB
|
100000 (count)
|
0-206582400
|
MXP-2_5G-10E.pmthresholds.client.rs.nearend.1day.ES
|
5000 (seconds)
|
0-86400
|
MXP-2_5G-10E.pmthresholds.client.rs.nearend.1day.SES
|
5000 (seconds)
|
0-86400
|
MXP-2_5G-10E.pmthresholds.client.rs.nearend.1day.UAS
|
10 (seconds)
|
0-86400
|
D.3.1.3 MXP_MR_2.5G Card Default Settings
Table D-15 lists the MXP_MR_2.5G card default settings.
Table D-15 MXP_MR_2.5G Card Default Settings (ETSI)
Default Name
|
Default Value
|
Default Domain
|
MXP-MR-2_5G.config.client.AlsMode
|
Disabled
|
Disabled, Manual Restart, Manual Restart for Test
|
MXP-MR-2_5G.config.client.AlsRecoveryPulseDuration
|
4.0 (seconds)
|
•2.0, 2.1, 2.2 .. 100.0 when AlsMode is Disabled, Auto Restart, Manual Restart
•80.0, 80.1, 80.2 .. 100.0 when AlsMode is Manual Restart for Test
|
MXP-MR-2_5G.config.client.AlsRecoveryPulseInterval
|
100 (seconds)
|
60-300
|
MXP-MR-2_5G.config.client.ppmPortAssignment
|
UNASSIGNED
|
UNASSIGNED, ONE_GE, FC1G ISL, FC2G ISL, FICON1G ISL, FICON2G ISL
|
MXP-MR-2_5G.config.client.ppmSlotAssignment
|
UNASSIGNED
|
UNASSIGNED, PPM (1 Port)
|
MXP-MR-2_5G.config.fc.distanceExtension.AutoadjustGFPBufferThreshold
|
TRUE
|
TRUE, FALSE
|
MXP-MR-2_5G.config.fc.distanceExtension.AutoDetect
|
TRUE
|
TRUE, FALSE
|
MXP-MR-2_5G.config.fc.distanceExtension.Enabled
|
TRUE
|
TRUE, FALSE
|
MXP-MR-2_5G.config.fc.distanceExtension.NumCredits
|
32
|
2-256
|
MXP-MR-2_5G.config.fc.distanceExtension.NumGFPBuffers
|
16
|
16, 32, 48 .. 1200
|
MXP-MR-2_5G.config.fc.enhancedFibreChannelFicon.MaxFrameSize
|
2148
|
2148, 2152, 2156, 2160, 2164, 2168, 2172
|
MXP-MR-2_5G.config.trunk.AINSSoakTime
|
08:00 (hours:mins)
|
00:00, 00:15, 00:30 .. 48:00
|
MXP-MR-2_5G.config.trunk.AlsMode
|
Disabled
|
Disabled, Auto Restart, Manual Restart, Manual Restart for Test
|
MXP-MR-2_5G.config.trunk.AlsRecoveryPulseDuration
|
4.0 (seconds)
|
•2.0, 2.1, 2.2 .. 100.0 when AlsMode is Disabled, Auto Restart, Manual Restart
•80.0, 80.1, 80.2 .. 100.0 when AlsMode is Manual Restart for Test
|
MXP-MR-2_5G.config.trunk.AlsRecoveryPulseInterval
|
100 (seconds)
|
60-300
|
MXP-MR-2_5G.config.trunk.SDBER
|
1E-7
|
1E-5, 1E-6, 1E-7, 1E-8, 1E-9
|
MXP-MR-2_5G.config.trunk.SendDoNotUse
|
FALSE
|
TRUE, FALSE
|
MXP-MR-2_5G.config.trunk.SFBER
|
1E-4
|
1E-3, 1E-4, 1E-5
|
MXP-MR-2_5G.config.trunk.SyncMsgIn
|
TRUE
|
FALSE, TRUE
|
MXP-MR-2_5G.opticalthresholds.client.alarm.HighLaserBias
|
90.0 (%)
|
0.0, 0.1, 0.2 .. 100.0
|
MXP-MR-2_5G.opticalthresholds.client.alarm.HighRxPower
|
3.0 (dBm)
|
LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0
|
MXP-MR-2_5G.opticalthresholds.client.alarm.HighTxPower
|
3.0 (dBm)
|
LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0
|
MXP-MR-2_5G.opticalthresholds.client.alarm.LowRxPower
|
-21.0 (dBm)
|
-40.0, -39.9, -39.8 .. HighRxPower
|
MXP-MR-2_5G.opticalthresholds.client.alarm.LowTxPower
|
-8.0 (dBm)
|
-40.0, -39.9, -39.8 .. HighTxPower
|
MXP-MR-2_5G.opticalthresholds.client.warning.15min.HighLaserBias
|
81.0 (%)
|
0.0, 0.1, 0.2 .. 100.0
|
MXP-MR-2_5G.opticalthresholds.client.warning.15min.HighRxPower
|
2.0 (dBm)
|
LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0
|
MXP-MR-2_5G.opticalthresholds.client.warning.15min.HighTxPower
|
2.0 (dBm)
|
LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0
|
MXP-MR-2_5G.opticalthresholds.client.warning.15min.LowRxPower
|
-20.0 (dBm)
|
-40.0, -39.9, -39.8 .. HighRxPower
|
MXP-MR-2_5G.opticalthresholds.client.warning.15min.LowTxPower
|
-7.0 (dBm)
|
-40.0, -39.9, -39.8 .. HighTxPower
|
MXP-MR-2_5G.opticalthresholds.client.warning.1day.HighLaserBias
|
85.5 (%)
|
0.0, 0.1, 0.2 .. 100.0
|
MXP-MR-2_5G.opticalthresholds.client.warning.1day.HighRxPower
|
2.5 (dBm)
|
LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0
|
MXP-MR-2_5G.opticalthresholds.client.warning.1day.HighTxPower
|
2.5 (dBm)
|
LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0
|
MXP-MR-2_5G.opticalthresholds.client.warning.1day.LowRxPower
|
-20.5 (dBm)
|
-40.0, -39.9, -39.8 .. HighRxPower
|
MXP-MR-2_5G.opticalthresholds.client.warning.1day.LowTxPower
|
-7.5 (dBm)
|
-40.0, -39.9, -39.8 .. HighTxPower
|
MXP-MR-2_5G.opticalthresholds.trunk.alarm.HighLaserBias
|
98.0 (%)
|
0.0, 0.1, 0.2 .. 100.0
|
MXP-MR-2_5G.opticalthresholds.trunk.alarm.HighRxPower
|
-8.0 (dBm)
|
LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0
|
MXP-MR-2_5G.opticalthresholds.trunk.alarm.HighTxPower
|
30.0 (dBm)
|
LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0
|
MXP-MR-2_5G.opticalthresholds.trunk.alarm.LowRxPower
|
-25.0 (dBm)
|
-40.0, -39.9, -39.8 .. HighRxPower
|
MXP-MR-2_5G.opticalthresholds.trunk.alarm.LowTxPower
|
-40.0 (dBm)
|
-40.0, -39.9, -39.8 .. HighTxPower
|
MXP-MR-2_5G.opticalthresholds.trunk.warning.15min.HighLaserBias
|
95.0 (%)
|
0.0, 0.1, 0.2 .. 100.0
|
MXP-MR-2_5G.opticalthresholds.trunk.warning.15min.HighRxPower
|
-7.5 (dBm)
|
LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0
|
MXP-MR-2_5G.opticalthresholds.trunk.warning.15min.HighTxPower
|
30.0 (dBm)
|
LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0
|
MXP-MR-2_5G.opticalthresholds.trunk.warning.15min.LowRxPower
|
-24.5 (dBm)
|
-40.0, -39.9, -39.8 .. HighRxPower
|
MXP-MR-2_5G.opticalthresholds.trunk.warning.15min.LowTxPower
|
-40.0 (dBm)
|
-40.0, -39.9, -39.8 .. HighTxPower
|
MXP-MR-2_5G.opticalthresholds.trunk.warning.1day.HighLaserBias
|
96.0 (%)
|
0.0, 0.1, 0.2 .. 100.0
|
MXP-MR-2_5G.opticalthresholds.trunk.warning.1day.HighRxPower
|
-7.3 (dBm)
|
LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0
|
MXP-MR-2_5G.opticalthresholds.trunk.warning.1day.HighTxPower
|
30.0 (dBm)
|
LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0
|
MXP-MR-2_5G.opticalthresholds.trunk.warning.1day.LowRxPower
|
-24.7 (dBm)
|
-40.0, -39.9, -39.8 .. HighRxPower
|
MXP-MR-2_5G.opticalthresholds.trunk.warning.1day.LowTxPower
|
-40.0 (dBm)
|
-40.0, -39.9, -39.8 .. HighTxPower
|
MXP-MR-2_5G.pmthresholds.trunk.ms.farend.15min.BBE
|
21260 (count)
|
0-2212200
|
MXP-MR-2_5G.pmthresholds.trunk.ms.farend.15min.EB
|
21260 (count)
|
0-2212200
|
MXP-MR-2_5G.pmthresholds.trunk.ms.farend.15min.ES
|
87 (seconds)
|
0-900
|
MXP-MR-2_5G.pmthresholds.trunk.ms.farend.15min.SES
|
1 (seconds)
|
0-900
|
MXP-MR-2_5G.pmthresholds.trunk.ms.farend.15min.UAS
|
3 (seconds)
|
0-900
|
MXP-MR-2_5G.pmthresholds.trunk.ms.farend.1day.BBE
|
212600 (count)
|
0-2212200
|
MXP-MR-2_5G.pmthresholds.trunk.ms.farend.1day.EB
|
212600 (count)
|
0-212371200
|
MXP-MR-2_5G.pmthresholds.trunk.ms.farend.1day.ES
|
864 (seconds)
|
0-86400
|
MXP-MR-2_5G.pmthresholds.trunk.ms.farend.1day.SES
|
4 (seconds)
|
0-86400
|
MXP-MR-2_5G.pmthresholds.trunk.ms.farend.1day.UAS
|
10 (seconds)
|
0-86400
|
MXP-MR-2_5G.pmthresholds.trunk.ms.nearend.15min.BBE
|
21260 (count)
|
0-2212200
|
MXP-MR-2_5G.pmthresholds.trunk.ms.nearend.15min.EB
|
21260 (count)
|
0-2212200
|
MXP-MR-2_5G.pmthresholds.trunk.ms.nearend.15min.ES
|
87 (seconds)
|
0-900
|
MXP-MR-2_5G.pmthresholds.trunk.ms.nearend.15min.SES
|
1 (seconds)
|
0-900
|
MXP-MR-2_5G.pmthresholds.trunk.ms.nearend.15min.UAS
|
3 (seconds)
|
0-900
|
MXP-MR-2_5G.pmthresholds.trunk.ms.nearend.1day.BBE
|
212600 (count)
|
0-2212200
|
MXP-MR-2_5G.pmthresholds.trunk.ms.nearend.1day.EB
|
212600 (count)
|
0-212371200
|
MXP-MR-2_5G.pmthresholds.trunk.ms.nearend.1day.ES
|
864 (seconds)
|
0-86400
|
MXP-MR-2_5G.pmthresholds.trunk.ms.nearend.1day.SES
|
4 (seconds)
|
0-86400
|
MXP-MR-2_5G.pmthresholds.trunk.ms.nearend.1day.UAS
|
10 (seconds)
|
0-86400
|
MXP-MR-2_5G.pmthresholds.trunk.rs.nearend.15min.BBE
|
10000 (count)
|
0-2151900
|
MXP-MR-2_5G.pmthresholds.trunk.rs.nearend.15min.EB
|
10000 (count)
|
0-2151900
|
MXP-MR-2_5G.pmthresholds.trunk.rs.nearend.15min.ES
|
500 (seconds)
|
0-900
|
MXP-MR-2_5G.pmthresholds.trunk.rs.nearend.15min.SES
|
500 (seconds)
|
0-900
|
MXP-MR-2_5G.pmthresholds.trunk.rs.nearend.15min.UAS
|
3 (seconds)
|
0-900
|
MXP-MR-2_5G.pmthresholds.trunk.rs.nearend.1day.BBE
|
100000 (count)
|
0-206582400
|
MXP-MR-2_5G.pmthresholds.trunk.rs.nearend.1day.EB
|
100000 (count)
|
0-206582400
|
MXP-MR-2_5G.pmthresholds.trunk.rs.nearend.1day.ES
|
5000 (seconds)
|
0-86400
|
MXP-MR-2_5G.pmthresholds.trunk.rs.nearend.1day.SES
|
5000 (seconds)
|
0-86400
|
MXP-MR-2_5G.pmthresholds.trunk.rs.nearend.1day.UAS
|
10 (seconds)
|
0-86400
|
D.3.1.4 MXPP_MR_2.5G Card Default Settings
Table D-16 lists the MXPP_MR_2.5G card default settings.
Table D-16 MXPP_MR_2.5G Card Default Settings (ETSI)
Default Name
|
Default Value
|
Default Domain
|
MXPP-MR-2_5G.config.client.AlsMode
|
Disabled
|
Disabled, Manual Restart, Manual Restart for Test
|
MXPP-MR-2_5G.config.client.AlsRecoveryPulseDuration
|
4.0 (seconds)
|
•2.0, 2.1, 2.2 .. 100.0 when AlsMode is Disabled, Auto Restart, Manual Restart
•80.0, 80.1, 80.2 .. 100.0 when AlsMode is Manual Restart for Test
|
MXPP-MR-2_5G.config.client.AlsRecoveryPulseInterval
|
100 (seconds)
|
60-300
|
MXPP-MR-2_5G.config.client.ppmPortAssignment
|
UNASSIGNED
|
UNASSIGNED, ONE_GE, FC1G ISL, FC2G ISL, FICON1G ISL, FICON2G ISL
|
MXPP-MR-2_5G.config.client.ppmSlotAssignment
|
UNASSIGNED
|
UNASSIGNED, PPM (1 Port)
|
MXPP-MR-2_5G.config.fc.distanceExtension.AutoadjustGFPBufferThreshold
|
TRUE
|
TRUE, FALSE
|
MXPP-MR-2_5G.config.fc.distanceExtension.AutoDetect
|
TRUE
|
TRUE, FALSE
|
MXPP-MR-2_5G.config.fc.distanceExtension.Enabled
|
TRUE
|
TRUE, FALSE
|
MXPP-MR-2_5G.config.fc.distanceExtension.NumCredits
|
32
|
2-256
|
MXPP-MR-2_5G.config.fc.distanceExtension.NumGFPBuffers
|
16
|
16, 32, 48 .. 1200
|
MXPP-MR-2_5G.config.fc.enhancedFibreChannelFicon.MaxFrameSize
|
2148
|
2148, 2152, 2156, 2160, 2164, 2168, 2172
|
MXPP-MR-2_5G.config.trunk.AINSSoakTime
|
08:00 (hours:mins)
|
00:00, 00:15, 00:30 .. 48:00
|
MXPP-MR-2_5G.config.trunk.AlsMode
|
Disabled
|
Disabled, Auto Restart, Manual Restart, Manual Restart for Test
|
MXPP-MR-2_5G.config.trunk.AlsRecoveryPulseDuration
|
4.0 (seconds)
|
•2.0, 2.1, 2.2 .. 100.0 when AlsMode is Disabled, Auto Restart, Manual Restart
•80.0, 80.1, 80.2 .. 100.0 when AlsMode is Manual Restart for Test
|
MXPP-MR-2_5G.config.trunk.AlsRecoveryPulseInterval
|
100 (seconds)
|
60-300
|
MXPP-MR-2_5G.config.trunk.SDBER
|
1E-7
|
1E-5, 1E-6, 1E-7, 1E-8, 1E-9
|
MXPP-MR-2_5G.config.trunk.SFBER
|
1E-4
|
1E-3, 1E-4, 1E-5
|
MXPP-MR-2_5G.opticalthresholds.client.alarm.HighLaserBias
|
90.0 (%)
|
0.0, 0.1, 0.2 .. 100.0
|
MXPP-MR-2_5G.opticalthresholds.client.alarm.HighRxPower
|
3.0 (dBm)
|
LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0
|
MXPP-MR-2_5G.opticalthresholds.client.alarm.HighTxPower
|
3.0 (dBm)
|
LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0
|
MXPP-MR-2_5G.opticalthresholds.client.alarm.LowRxPower
|
-21.0 (dBm)
|
-40.0, -39.9, -39.8 .. HighRxPower
|
MXPP-MR-2_5G.opticalthresholds.client.alarm.LowTxPower
|
-8.0 (dBm)
|
-40.0, -39.9, -39.8 .. HighTxPower
|
MXPP-MR-2_5G.opticalthresholds.client.warning.15min.HighLaserBias
|
81.0 (%)
|
0.0, 0.1, 0.2 .. 100.0
|
MXPP-MR-2_5G.opticalthresholds.client.warning.15min.HighRxPower
|
2.0 (dBm)
|
LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0
|
MXPP-MR-2_5G.opticalthresholds.client.warning.15min.HighTxPower
|
2.0 (dBm)
|
LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0
|
MXPP-MR-2_5G.opticalthresholds.client.warning.15min.LowRxPower
|
-20.0 (dBm)
|
-40.0, -39.9, -39.8 .. HighRxPower
|
MXPP-MR-2_5G.opticalthresholds.client.warning.15min.LowTxPower
|
-7.0 (dBm)
|
-40.0, -39.9, -39.8 .. HighTxPower
|
MXPP-MR-2_5G.opticalthresholds.client.warning.1day.HighLaserBias
|
85.5 (%)
|
0.0, 0.1, 0.2 .. 100.0
|
MXPP-MR-2_5G.opticalthresholds.client.warning.1day.HighRxPower
|
2.5 (dBm)
|
LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0
|
MXPP-MR-2_5G.opticalthresholds.client.warning.1day.HighTxPower
|
2.5 (dBm)
|
LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0
|
MXPP-MR-2_5G.opticalthresholds.client.warning.1day.LowRxPower
|
-20.5 (dBm)
|
-40.0, -39.9, -39.8 .. HighRxPower
|
MXPP-MR-2_5G.opticalthresholds.client.warning.1day.LowTxPower
|
-7.5 (dBm)
|
-40.0, -39.9, -39.8 .. HighTxPower
|
MXPP-MR-2_5G.opticalthresholds.trunk.alarm.HighLaserBias
|
98.0 (%)
|
0.0, 0.1, 0.2 .. 100.0
|
MXPP-MR-2_5G.opticalthresholds.trunk.alarm.HighRxPower
|
-8.0 (dBm)
|
LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0
|
MXPP-MR-2_5G.opticalthresholds.trunk.alarm.HighTxPower
|
30.0 (dBm)
|
LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0
|
MXPP-MR-2_5G.opticalthresholds.trunk.alarm.LowRxPower
|
-25.0 (dBm)
|
-40.0, -39.9, -39.8 .. HighRxPower
|
MXPP-MR-2_5G.opticalthresholds.trunk.alarm.LowTxPower
|
-40.0 (dBm)
|
-40.0, -39.9, -39.8 .. HighTxPower
|
MXPP-MR-2_5G.opticalthresholds.trunk.warning.15min.HighLaserBias
|
95.0 (%)
|
0.0, 0.1, 0.2 .. 100.0
|
MXPP-MR-2_5G.opticalthresholds.trunk.warning.15min.HighRxPower
|
-7.5 (dBm)
|
LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0
|
MXPP-MR-2_5G.opticalthresholds.trunk.warning.15min.HighTxPower
|
30.0 (dBm)
|
LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0
|
MXPP-MR-2_5G.opticalthresholds.trunk.warning.15min.LowRxPower
|
-24.5 (dBm)
|
-40.0, -39.9, -39.8 .. HighRxPower
|
MXPP-MR-2_5G.opticalthresholds.trunk.warning.15min.LowTxPower
|
-40.0 (dBm)
|
-40.0, -39.9, -39.8 .. HighTxPower
|
MXPP-MR-2_5G.opticalthresholds.trunk.warning.1day.HighLaserBias
|
96.0 (%)
|
0.0, 0.1, 0.2 .. 100.0
|
MXPP-MR-2_5G.opticalthresholds.trunk.warning.1day.HighRxPower
|
-7.3 (dBm)
|
LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0
|
MXPP-MR-2_5G.opticalthresholds.trunk.warning.1day.HighTxPower
|
30.0 (dBm)
|
LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0
|
MXPP-MR-2_5G.opticalthresholds.trunk.warning.1day.LowRxPower
|
-24.7 (dBm)
|
-40.0, -39.9, -39.8 .. HighRxPower
|
MXPP-MR-2_5G.opticalthresholds.trunk.warning.1day.LowTxPower
|
-40.0 (dBm)
|
-40.0, -39.9, -39.8 .. HighTxPower
|
MXPP-MR-2_5G.pmthresholds.trunk.ms.farend.15min.BBE
|
21260 (count)
|
0-2212200
|
MXPP-MR-2_5G.pmthresholds.trunk.ms.farend.15min.EB
|
21260 (count)
|
0-2212200
|
MXPP-MR-2_5G.pmthresholds.trunk.ms.farend.15min.ES
|
87 (seconds)
|
0-900
|
MXPP-MR-2_5G.pmthresholds.trunk.ms.farend.15min.SES
|
1 (seconds)
|
0-900
|
MXPP-MR-2_5G.pmthresholds.trunk.ms.farend.15min.UAS
|
3 (seconds)
|
0-900
|
MXPP-MR-2_5G.pmthresholds.trunk.ms.farend.1day.BBE
|
212600 (count)
|
0-2212200
|
MXPP-MR-2_5G.pmthresholds.trunk.ms.farend.1day.EB
|
212600 (count)
|
0-212371200
|
MXPP-MR-2_5G.pmthresholds.trunk.ms.farend.1day.ES
|
864 (seconds)
|
0-86400
|
MXPP-MR-2_5G.pmthresholds.trunk.ms.farend.1day.SES
|
4 (seconds)
|
0-86400
|
MXPP-MR-2_5G.pmthresholds.trunk.ms.farend.1day.UAS
|
10 (seconds)
|
0-86400
|
MXPP-MR-2_5G.pmthresholds.trunk.ms.nearend.15min.BBE
|
21260 (count)
|
0-2212200
|
MXPP-MR-2_5G.pmthresholds.trunk.ms.nearend.15min.EB
|
21260 (count)
|
0-2212200
|
MXPP-MR-2_5G.pmthresholds.trunk.ms.nearend.15min.ES
|
87 (seconds)
|
0-900
|
MXPP-MR-2_5G.pmthresholds.trunk.ms.nearend.15min.SES
|
1 (seconds)
|
0-900
|
MXPP-MR-2_5G.pmthresholds.trunk.ms.nearend.15min.UAS
|
3 (seconds)
|
0-900
|
MXPP-MR-2_5G.pmthresholds.trunk.ms.nearend.1day.BBE
|
212600 (count)
|
0-2212200
|
MXPP-MR-2_5G.pmthresholds.trunk.ms.nearend.1day.EB
|
212600 (count)
|
0-212371200
|
MXPP-MR-2_5G.pmthresholds.trunk.ms.nearend.1day.ES
|
864 (seconds)
|
0-86400
|
MXPP-MR-2_5G.pmthresholds.trunk.ms.nearend.1day.SES
|
4 (seconds)
|
0-86400
|
MXPP-MR-2_5G.pmthresholds.trunk.ms.nearend.1day.UAS
|
10 (seconds)
|
0-86400
|
MXPP-MR-2_5G.pmthresholds.trunk.rs.nearend.15min.BBE
|
10000 (count)
|
0-2151900
|
MXPP-MR-2_5G.pmthresholds.trunk.rs.nearend.15min.EB
|
10000 (count)
|
0-2151900
|
MXPP-MR-2_5G.pmthresholds.trunk.rs.nearend.15min.ES
|
500 (seconds)
|
0-900
|
MXPP-MR-2_5G.pmthresholds.trunk.rs.nearend.15min.SES
|
500 (seconds)
|
0-900
|
MXPP-MR-2_5G.pmthresholds.trunk.rs.nearend.15min.UAS
|
3 (seconds)
|
0-900
|
MXPP-MR-2_5G.pmthresholds.trunk.rs.nearend.1day.BBE
|
100000 (count)
|
0-206582400
|
MXPP-MR-2_5G.pmthresholds.trunk.rs.nearend.1day.EB
|
100000 (count)
|
0-206582400
|
MXPP-MR-2_5G.pmthresholds.trunk.rs.nearend.1day.ES
|
5000 (seconds)
|
0-86400
|
MXPP-MR-2_5G.pmthresholds.trunk.rs.nearend.1day.SES
|
5000 (seconds)
|
0-86400
|
MXPP-MR-2_5G.pmthresholds.trunk.rs.nearend.1day.UAS
|
10 (seconds)
|
0-86400
|
D.3.1.5 TXP_MR_10E Card Default Settings
Table D-17 lists the TXP_MR_10E card default settings.
Table D-17 TXP_MR_10E Card Default Settings (ETSI)
Default Name
|
Default Value
|
Default Domain
|
TXP-MR-10E.config.client.AINSSoakTime
|
08:00 (hours:mins)
|
00:00, 00:15, 00:30 .. 48:00
|
TXP-MR-10E.config.client.AisSquelchMode
|
Squelch
|
Ais, Squelch
|
TXP-MR-10E.config.client.AlsMode
|
Disabled
|
Disabled, Auto Restart, Manual Restart, Manual Restart for Test
|
TXP-MR-10E.config.client.AlsRecoveryPulseDuration
|
2.0 (seconds)
|
•2.0, 2.1, 2.2 .. 100.0 when AlsMode is Disabled, Auto Restart, Manual Restart
•80.0, 80.1, 80.2 .. 100.0 when AlsMode is Manual Restart for Test
|
TXP-MR-10E.config.client.AlsRecoveryPulseInterval
|
100 (seconds)
|
100-2000
|
TXP-MR-10E.config.client.ppmPortAssignment
|
UNASSIGNED
|
UNASSIGNED, SDH, 10G Ethernet, 10G Fiber Channel
|
TXP-MR-10E.config.client.ppmSlotAssignment
|
UNASSIGNED
|
UNASSIGNED, PPM (1 Port)
|
TXP-MR-10E.config.client.SDBER
|
1E-7
|
1E-5, 1E-6, 1E-7, 1E-8, 1E-9
|
TXP-MR-10E.config.client.SendDoNotUse
|
FALSE
|
TRUE, FALSE
|
TXP-MR-10E.config.client.SFBER
|
1E-4
|
1E-3, 1E-4, 1E-5
|
TXP-MR-10E.config.client.SyncMsgIn
|
TRUE
|
FALSE, TRUE
|
TXP-MR-10E.config.client.TerminationMode
|
Transparent
|
•Transparent, Regeneration Section, Multiplex Section when ppmPortAssignment is UNASSIGNED, SONET
•Transparent when ppmPortAssignment is 10G Ethernet, 10G Fiber Channel
|
TXP-MR-10E.config.trunk.AINSSoakTime
|
08:00 (hours:mins)
|
00:00, 00:15, 00:30 .. 48:00
|
TXP-MR-10E.config.trunk.AlsMode
|
Disabled
|
Disabled, Auto Restart, Manual Restart, Manual Restart for Test
|
TXP-MR-10E.config.trunk.AlsRecoveryPulseDuration
|
100.0 (seconds)
|
•6.0, 6.1, 6.2 .. 200.0 when AlsMode is Disabled, Auto Restart, Manual Restart
•80.0, 80.1, 80.2 .. 100.0 when AlsMode is Manual Restart for Test
|
TXP-MR-10E.config.trunk.AlsRecoveryPulseInterval
|
300 (seconds)
|
200-2000
|
TXP-MR-10E.config.trunk.SDBER
|
1E-7
|
1E-5, 1E-6, 1E-7, 1E-8, 1E-9
|
TXP-MR-10E.config.trunk.SFBER
|
1E-4
|
1E-3, 1E-4, 1E-5
|
TXP-MR-10E.opticalthresholds.client.alarm.HighLaserBias
|
90.0 (%)
|
0.0, 0.1, 0.2 .. 100.0
|
TXP-MR-10E.opticalthresholds.client.alarm.HighRxPower
|
2.0 (dBm)
|
-17.0, -16.9, -16.8 .. 30.0
|
TXP-MR-10E.opticalthresholds.client.alarm.HighTxPower
|
2.0 (dBm)
|
-9.0, -8.9, -8.8 .. 30.0
|
TXP-MR-10E.opticalthresholds.client.alarm.LowRxPower
|
-17.0 (dBm)
|
-40.0, -39.9, -39.8 .. 2.0
|
TXP-MR-10E.opticalthresholds.client.alarm.LowTxPower
|
-9.0 (dBm)
|
-40.0, -39.9, -39.8 .. 2.0
|
TXP-MR-10E.opticalthresholds.client.warning.15min.HighLaserBias
|
81.0 (%)
|
0.0, 0.1, 0.2 .. 100.0
|
TXP-MR-10E.opticalthresholds.client.warning.15min.HighRxPower
|
1.0 (dBm)
|
-16.0, -15.9, -15.8 .. 30.0
|
TXP-MR-10E.opticalthresholds.client.warning.15min.HighTxPower
|
1.0 (dBm)
|
-8.0, -7.9, -7.8 .. 30.0
|
TXP-MR-10E.opticalthresholds.client.warning.15min.LowRxPower
|
-16.0 (dBm)
|
-40.0, -39.9, -39.8 .. 1.0
|
TXP-MR-10E.opticalthresholds.client.warning.15min.LowTxPower
|
-8.0 (dBm)
|
-40.0, -39.9, -39.8 .. 1.0
|
TXP-MR-10E.opticalthresholds.client.warning.1day.HighLaserBias
|
85.5 (%)
|
0.0, 0.1, 0.2 .. 100.0
|
TXP-MR-10E.opticalthresholds.client.warning.1day.HighRxPower
|
1.5 (dBm)
|
-16.5, -16.4, -16.3 .. 30.0
|
TXP-MR-10E.opticalthresholds.client.warning.1day.HighTxPower
|
1.5 (dBm)
|
-8.5, -8.4, -8.3 .. 30.0
|
TXP-MR-10E.opticalthresholds.client.warning.1day.LowRxPower
|
-16.5 (dBm)
|
-40.0, -39.9, -39.8 .. 1.5
|
TXP-MR-10E.opticalthresholds.client.warning.1day.LowTxPower
|
-8.5 (dBm)
|
-40.0, -39.9, -39.8 .. 1.5
|
TXP-MR-10E.opticalthresholds.trunk.alarm.HighLaserBias
|
98.0 (%)
|
0.0, 0.1, 0.2 .. 100.0
|
TXP-MR-10E.opticalthresholds.trunk.alarm.HighRxPower
|
-8.0 (dBm)
|
-25.0, -24.9, -24.8 .. 30.0
|
TXP-MR-10E.opticalthresholds.trunk.alarm.HighTxPower
|
8.0 (dBm)
|
1.0, 1.1, 1.2 .. 30.0
|
TXP-MR-10E.opticalthresholds.trunk.alarm.LowRxPower
|
-25.0 (dBm)
|
-40.0, -39.9, -39.8 .. -8.0
|
TXP-MR-10E.opticalthresholds.trunk.alarm.LowTxPower
|
1.0 (dBm)
|
-40.0, -39.9, -39.8 .. 8.0
|
TXP-MR-10E.opticalthresholds.trunk.warning.15min.HighLaserBias
|
95.0 (%)
|
0.0, 0.1, 0.2 .. 100.0
|
TXP-MR-10E.opticalthresholds.trunk.warning.15min.HighRxPower
|
-7.5 (dBm)
|
-24.5, -24.4, -24.3 .. 30.0
|
TXP-MR-10E.opticalthresholds.trunk.warning.15min.HighTxPower
|
7.0 (dBm)
|
2.0, 2.1, 2.2 .. 30.0
|
TXP-MR-10E.opticalthresholds.trunk.warning.15min.LowRxPower
|
-24.5 (dBm)
|
-40.0, -39.9, -39.8 .. -7.5
|
TXP-MR-10E.opticalthresholds.trunk.warning.15min.LowTxPower
|
2.0 (dBm)
|
-40.0, -39.9, -39.8 .. 7.0
|
TXP-MR-10E.opticalthresholds.trunk.warning.1day.HighLaserBias
|
96.0 (%)
|
0.0, 0.1, 0.2 .. 100.0
|
TXP-MR-10E.opticalthresholds.trunk.warning.1day.HighRxPower
|
-7.3 (dBm)
|
-24.7, -24.6, -24.5 .. 30.0
|
TXP-MR-10E.opticalthresholds.trunk.warning.1day.HighTxPower
|
7.0 (dBm)
|
2.0, 2.1, 2.2 .. 30.0
|
TXP-MR-10E.opticalthresholds.trunk.warning.1day.LowRxPower
|
-24.7 (dBm)
|
-40.0, -39.9, -39.8 .. -7.3
|
TXP-MR-10E.opticalthresholds.trunk.warning.1day.LowTxPower
|
2.0 (dBm)
|
-40.0, -39.9, -39.8 .. 7.0
|
TXP-MR-10E.otn.fecthresholds.enhanced.15min.BitErrorsCorrected
|
903330 (count)
|
0-9033621811200
|
TXP-MR-10E.otn.fecthresholds.enhanced.15min.UncorrectableWords
|
5 (count)
|
0-4724697600
|
TXP-MR-10E.otn.fecthresholds.enhanced.1day.BitErrorsCorrected
|
86719680 (count)
|
0-867227693875200
|
TXP-MR-10E.otn.fecthresholds.enhanced.1day.UncorrectableWords
|
480 (count)
|
0-453570969600
|
TXP-MR-10E.otn.fecthresholds.standard.15min.BitErrorsCorrected
|
903330 (count)
|
0-9033621811200
|
TXP-MR-10E.otn.fecthresholds.standard.15min.UncorrectableWords
|
5 (count)
|
0-4724697600
|
TXP-MR-10E.otn.fecthresholds.standard.1day.BitErrorsCorrected
|
86719680 (count)
|
0-867227693875200
|
TXP-MR-10E.otn.fecthresholds.standard.1day.UncorrectableWords
|
480 (count)
|
0-453570969600
|
TXP-MR-10E.otn.g709thresholds.pm.farend.15min.BBE
|
85040 (count)
|
0-8850600
|
TXP-MR-10E.otn.g709thresholds.pm.farend.15min.ES
|
87 (seconds)
|
0-900
|
TXP-MR-10E.otn.g709thresholds.pm.farend.15min.FC
|
10 (count)
|
0-72
|
TXP-MR-10E.otn.g709thresholds.pm.farend.15min.SES
|
1 (seconds)
|
0-900
|
TXP-MR-10E.otn.g709thresholds.pm.farend.15min.UAS
|
3 (seconds)
|
0-900
|
TXP-MR-10E.otn.g709thresholds.pm.farend.1day.BBE
|
850400 (count)
|
0-849657600
|
TXP-MR-10E.otn.g709thresholds.pm.farend.1day.ES
|
864 (seconds)
|
0-86400
|
TXP-MR-10E.otn.g709thresholds.pm.farend.1day.FC
|
40 (count)
|
0-6912
|
TXP-MR-10E.otn.g709thresholds.pm.farend.1day.SES
|
4 (seconds)
|
0-86400
|
TXP-MR-10E.otn.g709thresholds.pm.farend.1day.UAS
|
10 (seconds)
|
0-86400
|
TXP-MR-10E.otn.g709thresholds.pm.nearend.15min.BBE
|
85040 (count)
|
0-8850600
|
TXP-MR-10E.otn.g709thresholds.pm.nearend.15min.ES
|
87 (seconds)
|
0-900
|
TXP-MR-10E.otn.g709thresholds.pm.nearend.15min.FC
|
10 (count)
|
0-72
|
TXP-MR-10E.otn.g709thresholds.pm.nearend.15min.SES
|
1 (seconds)
|
0-900
|
TXP-MR-10E.otn.g709thresholds.pm.nearend.15min.UAS
|
3 (seconds)
|
0-900
|
TXP-MR-10E.otn.g709thresholds.pm.nearend.1day.BBE
|
850400 (count)
|
0-849657600
|
TXP-MR-10E.otn.g709thresholds.pm.nearend.1day.ES
|
864 (seconds)
|
0-86400
|
TXP-MR-10E.otn.g709thresholds.pm.nearend.1day.FC
|
40 (count)
|
0-6912
|
TXP-MR-10E.otn.g709thresholds.pm.nearend.1day.SES
|
4 (seconds)
|
0-86400
|
TXP-MR-10E.otn.g709thresholds.pm.nearend.1day.UAS
|
10 (seconds)
|
0-86400
|
TXP-MR-10E.otn.g709thresholds.sm.farend.15min.BBE
|
10000 (count)
|
0-8850600
|
TXP-MR-10E.otn.g709thresholds.sm.farend.15min.ES
|
500 (seconds)
|
0-900
|
TXP-MR-10E.otn.g709thresholds.sm.farend.15min.FC
|
10 (count)
|
0-72
|
TXP-MR-10E.otn.g709thresholds.sm.farend.15min.SES
|
500 (seconds)
|
0-900
|
TXP-MR-10E.otn.g709thresholds.sm.farend.15min.UAS
|
500 (seconds)
|
0-900
|
TXP-MR-10E.otn.g709thresholds.sm.farend.1day.BBE
|
100000 (count)
|
0-849657600
|
TXP-MR-10E.otn.g709thresholds.sm.farend.1day.ES
|
5000 (seconds)
|
0-86400
|
TXP-MR-10E.otn.g709thresholds.sm.farend.1day.FC
|
40 (count)
|
0-6912
|
TXP-MR-10E.otn.g709thresholds.sm.farend.1day.SES
|
5000 (seconds)
|
0-86400
|
TXP-MR-10E.otn.g709thresholds.sm.farend.1day.UAS
|
5000 (seconds)
|
0-86400
|
TXP-MR-10E.otn.g709thresholds.sm.nearend.15min.BBE
|
10000 (count)
|
0-8850600
|
TXP-MR-10E.otn.g709thresholds.sm.nearend.15min.ES
|
500 (seconds)
|
0-900
|
TXP-MR-10E.otn.g709thresholds.sm.nearend.15min.FC
|
10 (count)
|
0-72
|
TXP-MR-10E.otn.g709thresholds.sm.nearend.15min.SES
|
500 (seconds)
|
0-900
|
TXP-MR-10E.otn.g709thresholds.sm.nearend.15min.UAS
|
500 (seconds)
|
0-900
|
TXP-MR-10E.otn.g709thresholds.sm.nearend.1day.BBE
|
100000 (count)
|
0-849657600
|
TXP-MR-10E.otn.g709thresholds.sm.nearend.1day.ES
|
5000 (seconds)
|
0-86400
|
TXP-MR-10E.otn.g709thresholds.sm.nearend.1day.FC
|
40 (count)
|
0-6912
|
TXP-MR-10E.otn.g709thresholds.sm.nearend.1day.SES
|
5000 (seconds)
|
0-86400
|
TXP-MR-10E.otn.g709thresholds.sm.nearend.1day.UAS
|
5000 (seconds)
|
0-86400
|
TXP-MR-10E.otn.otnLines.AsynchSynchMapping
|
Synch Mapping
|
Asynch mapping, Synch Mapping
|
TXP-MR-10E.otn.otnLines.FEC
|
Standard
|
•Disable, Standard, Enhanced when G709OTN is Enable
•Disable when G709OTN is Disable
|
TXP-MR-10E.otn.otnLines.G709OTN
|
Enable
|
Disable, Enable
|
TXP-MR-10E.otn.otnLines.SDBER
|
1E-7
|
1E-5, 1E-6, 1E-7, 1E-8, 1E-9
|
TXP-MR-10E.pmthresholds.client.ms.farend.15min.BBE
|
85040 (count)
|
0-8850600
|
TXP-MR-10E.pmthresholds.client.ms.farend.15min.EB
|
85040 (count)
|
0-8850600
|
TXP-MR-10E.pmthresholds.client.ms.farend.15min.ES
|
87 (seconds)
|
0-900
|
TXP-MR-10E.pmthresholds.client.ms.farend.15min.SES
|
1 (seconds)
|
0-900
|
TXP-MR-10E.pmthresholds.client.ms.farend.15min.UAS
|
3 (seconds)
|
0-900
|
TXP-MR-10E.pmthresholds.client.ms.farend.1day.BBE
|
850400 (count)
|
0-849657600
|
TXP-MR-10E.pmthresholds.client.ms.farend.1day.EB
|
850400 (count)
|
0-849657600
|
TXP-MR-10E.pmthresholds.client.ms.farend.1day.ES
|
864 (seconds)
|
0-86400
|
TXP-MR-10E.pmthresholds.client.ms.farend.1day.SES
|
4 (seconds)
|
0-86400
|
TXP-MR-10E.pmthresholds.client.ms.farend.1day.UAS
|
10 (seconds)
|
0-86400
|
TXP-MR-10E.pmthresholds.client.ms.nearend.15min.BBE
|
85040 (count)
|
0-8850600
|
TXP-MR-10E.pmthresholds.client.ms.nearend.15min.EB
|
85040 (count)
|
0-8850600
|
TXP-MR-10E.pmthresholds.client.ms.nearend.15min.ES
|
87 (seconds)
|
0-900
|
TXP-MR-10E.pmthresholds.client.ms.nearend.15min.SES
|
1 (seconds)
|
0-900
|
TXP-MR-10E.pmthresholds.client.ms.nearend.15min.UAS
|
3 (seconds)
|
0-900
|
TXP-MR-10E.pmthresholds.client.ms.nearend.1day.BBE
|
850400 (count)
|
0-849657600
|
TXP-MR-10E.pmthresholds.client.ms.nearend.1day.EB
|
850400 (count)
|
0-849657600
|
TXP-MR-10E.pmthresholds.client.ms.nearend.1day.ES
|
864 (seconds)
|
0-86400
|
TXP-MR-10E.pmthresholds.client.ms.nearend.1day.SES
|
4 (seconds)
|
0-86400
|
TXP-MR-10E.pmthresholds.client.ms.nearend.1day.UAS
|
10 (seconds)
|
0-86400
|
TXP-MR-10E.pmthresholds.client.rs.nearend.15min.BBE
|
10000 (count)
|
0-8850600
|
TXP-MR-10E.pmthresholds.client.rs.nearend.15min.EB
|
10000 (count)
|
0-7967700
|
TXP-MR-10E.pmthresholds.client.rs.nearend.15min.ES
|
500 (seconds)
|
0-900
|
TXP-MR-10E.pmthresholds.client.rs.nearend.15min.SES
|
500 (seconds)
|
0-900
|
TXP-MR-10E.pmthresholds.client.rs.nearend.15min.UAS
|
3 (seconds)
|
0-900
|
TXP-MR-10E.pmthresholds.client.rs.nearend.1day.BBE
|
100000 (count)
|
0-849657600
|
TXP-MR-10E.pmthresholds.client.rs.nearend.1day.EB
|
100000 (count)
|
0-764899200
|
TXP-MR-10E.pmthresholds.client.rs.nearend.1day.ES
|
5000 (seconds)
|
0-86400
|
TXP-MR-10E.pmthresholds.client.rs.nearend.1day.SES
|
5000 (seconds)
|
0-86400
|
TXP-MR-10E.pmthresholds.client.rs.nearend.1day.UAS
|
10 (seconds)
|
0-86400
|
TXP-MR-10E.pmthresholds.trunk.ms.farend.15min.BBE
|
85040 (count)
|
0-8850600
|
TXP-MR-10E.pmthresholds.trunk.ms.farend.15min.EB
|
85040 (count)
|
0-8850600
|
TXP-MR-10E.pmthresholds.trunk.ms.farend.15min.ES
|
87 (seconds)
|
0-900
|
TXP-MR-10E.pmthresholds.trunk.ms.farend.15min.SES
|
1 (seconds)
|
0-900
|
TXP-MR-10E.pmthresholds.trunk.ms.farend.15min.UAS
|
3 (seconds)
|
0-900
|
TXP-MR-10E.pmthresholds.trunk.ms.farend.1day.BBE
|
850400 (count)
|
0-849657600
|
TXP-MR-10E.pmthresholds.trunk.ms.farend.1day.EB
|
850400 (count)
|
0-849657600
|
TXP-MR-10E.pmthresholds.trunk.ms.farend.1day.ES
|
864 (seconds)
|
0-86400
|
TXP-MR-10E.pmthresholds.trunk.ms.farend.1day.SES
|
4 (seconds)
|
0-86400
|
TXP-MR-10E.pmthresholds.trunk.ms.farend.1day.UAS
|
10 (seconds)
|
0-86400
|
TXP-MR-10E.pmthresholds.trunk.ms.nearend.15min.BBE
|
85040 (count)
|
0-8850600
|
TXP-MR-10E.pmthresholds.trunk.ms.nearend.15min.EB
|
85040 (count)
|
0-8850600
|
TXP-MR-10E.pmthresholds.trunk.ms.nearend.15min.ES
|
87 (seconds)
|
0-900
|
TXP-MR-10E.pmthresholds.trunk.ms.nearend.15min.SES
|
1 (seconds)
|
0-900
|
TXP-MR-10E.pmthresholds.trunk.ms.nearend.15min.UAS
|
3 (seconds)
|
0-900
|
TXP-MR-10E.pmthresholds.trunk.ms.nearend.1day.BBE
|
850400 (count)
|
0-849657600
|
TXP-MR-10E.pmthresholds.trunk.ms.nearend.1day.EB
|
850400 (count)
|
0-849657600
|
TXP-MR-10E.pmthresholds.trunk.ms.nearend.1day.ES
|
864 (seconds)
|
0-86400
|
TXP-MR-10E.pmthresholds.trunk.ms.nearend.1day.SES
|
4 (seconds)
|
0-86400
|
TXP-MR-10E.pmthresholds.trunk.ms.nearend.1day.UAS
|
10 (seconds)
|
0-86400
|
TXP-MR-10E.pmthresholds.trunk.rs.nearend.15min.BBE
|
10000 (count)
|
0-8850600
|
TXP-MR-10E.pmthresholds.trunk.rs.nearend.15min.EB
|
10000 (count)
|
0-7967700
|
TXP-MR-10E.pmthresholds.trunk.rs.nearend.15min.ES
|
500 (seconds)
|
0-900
|
TXP-MR-10E.pmthresholds.trunk.rs.nearend.15min.SES
|
500 (seconds)
|
0-900
|
TXP-MR-10E.pmthresholds.trunk.rs.nearend.15min.UAS
|
3 (seconds)
|
0-900
|
TXP-MR-10E.pmthresholds.trunk.rs.nearend.1day.BBE
|
100000 (count)
|
0-849657600
|
TXP-MR-10E.pmthresholds.trunk.rs.nearend.1day.EB
|
100000 (count)
|
0-764899200
|
TXP-MR-10E.pmthresholds.trunk.rs.nearend.1day.ES
|
5000 (seconds)
|
0-86400
|
TXP-MR-10E.pmthresholds.trunk.rs.nearend.1day.SES
|
5000 (seconds)
|
0-86400
|
TXP-MR-10E.pmthresholds.trunk.rs.nearend.1day.UAS
|
10 (seconds)
|
0-86400
|
D.3.1.6 TXP_MR_10G Card Default Settings
Table D-18 lists the TXP_MR_10G card default settings.
Table D-18 TXP_MR_10G Card Default Settings (ETSI)
Default Name
|
Default Value
|
Default Domain
|
TXP-MR-10G.config.client.AINSSoakTime
|
08:00 (hours:mins)
|
00:00, 00:15, 00:30 .. 48:00
|
TXP-MR-10G.config.client.AlsMode
|
Disabled
|
Disabled, Auto Restart, Manual Restart, Manual Restart for Test
|
TXP-MR-10G.config.client.AlsRecoveryPulseDuration
|
4.0 (seconds)
|
•2.0, 2.1, 2.2 .. 100.0 when AlsMode is Disabled, Auto Restart, Manual Restart
•80.0, 80.1, 80.2 .. 100.0 when AlsMode is Manual Restart for Test
|
TXP-MR-10G.config.client.AlsRecoveryPulseInterval
|
100 (seconds)
|
100-300
|
TXP-MR-10G.config.client.mrPortAssignment
|
UNASSIGNED
|
UNASSIGNED, SDH, 10G Ethernet
|
TXP-MR-10G.config.client.SDBER
|
1E-7
|
1E-5, 1E-6, 1E-7, 1E-8, 1E-9
|
TXP-MR-10G.config.client.SFBER
|
1E-4
|
1E-3, 1E-4, 1E-5
|
TXP-MR-10G.config.client.TerminationMode
|
Transparent
|
•Transparent, Regeneration Section, Multiplex Section when mrPortAssignment is UNASSIGNED, SDH
•Transparent when mrPortAssignment is 10G Ethernet
|
TXP-MR-10G.config.trunk.AINSSoakTime
|
08:00 (hours:mins)
|
00:00, 00:15, 00:30 .. 48:00
|
TXP-MR-10G.config.trunk.AlsMode
|
Disabled
|
Disabled, Auto Restart, Manual Restart, Manual Restart for Test
|
TXP-MR-10G.config.trunk.AlsRecoveryPulseDuration
|
4.0 (seconds)
|
•2.0, 2.1, 2.2 .. 100.0 when AlsMode is Disabled, Auto Restart, Manual Restart
•80.0, 80.1, 80.2 .. 100.0 when AlsMode is Manual Restart for Test
|
TXP-MR-10G.config.trunk.AlsRecoveryPulseInterval
|
100 (seconds)
|
60-300
|
TXP-MR-10G.config.trunk.SDBER
|
1E-7
|
1E-5, 1E-6, 1E-7, 1E-8, 1E-9
|
TXP-MR-10G.config.trunk.SFBER
|
1E-4
|
1E-3, 1E-4, 1E-5
|
TXP-MR-10G.opticalthresholds.client.alarm.HighLaserBias
|
90.0 (%)
|
0.0, 0.1, 0.2 .. 100.0
|
TXP-MR-10G.opticalthresholds.client.alarm.HighRxPower
|
2.0 (dBm)
|
LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0
|
TXP-MR-10G.opticalthresholds.client.alarm.HighTxPower
|
2.0 (dBm)
|
LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0
|
TXP-MR-10G.opticalthresholds.client.alarm.LowRxPower
|
-17.0 (dBm)
|
-40.0, -39.9, -39.8 .. HighRxPower
|
TXP-MR-10G.opticalthresholds.client.alarm.LowTxPower
|
-9.0 (dBm)
|
-40.0, -39.9, -39.8 .. HighTxPower
|
TXP-MR-10G.opticalthresholds.client.warning.15min.HighLaserBias
|
81.0 (%)
|
0.0, 0.1, 0.2 .. 100.0
|
TXP-MR-10G.opticalthresholds.client.warning.15min.HighRxPower
|
1.0 (dBm)
|
LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0
|
TXP-MR-10G.opticalthresholds.client.warning.15min.HighTxPower
|
1.0 (dBm)
|
LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0
|
TXP-MR-10G.opticalthresholds.client.warning.15min.LowRxPower
|
-16.0 (dBm)
|
-40.0, -39.9, -39.8 .. HighRxPower
|
TXP-MR-10G.opticalthresholds.client.warning.15min.LowTxPower
|
-8.0 (dBm)
|
-40.0, -39.9, -39.8 .. HighTxPower
|
TXP-MR-10G.opticalthresholds.client.warning.1day.HighLaserBias
|
85.5 (%)
|
0.0, 0.1, 0.2 .. 100.0
|
TXP-MR-10G.opticalthresholds.client.warning.1day.HighRxPower
|
1.5 (dBm)
|
LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0
|
TXP-MR-10G.opticalthresholds.client.warning.1day.HighTxPower
|
1.5 (dBm)
|
LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0
|
TXP-MR-10G.opticalthresholds.client.warning.1day.LowRxPower
|
-16.5 (dBm)
|
-40.0, -39.9, -39.8 .. HighRxPower
|
TXP-MR-10G.opticalthresholds.client.warning.1day.LowTxPower
|
-8.5 (dBm)
|
-40.0, -39.9, -39.8 .. HighTxPower
|
TXP-MR-10G.opticalthresholds.trunk.alarm.HighLaserBias
|
90.0 (%)
|
0.0, 0.1, 0.2 .. 100.0
|
TXP-MR-10G.opticalthresholds.trunk.alarm.HighRxPower
|
-8.0 (dBm)
|
LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0
|
TXP-MR-10G.opticalthresholds.trunk.alarm.HighTxPower
|
4.0 (dBm)
|
LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0
|
TXP-MR-10G.opticalthresholds.trunk.alarm.LowRxPower
|
-25.0 (dBm)
|
-40.0, -39.9, -39.8 .. HighRxPower
|
TXP-MR-10G.opticalthresholds.trunk.alarm.LowTxPower
|
2.0 (dBm)
|
-40.0, -39.9, -39.8 .. HighTxPower
|
TXP-MR-10G.opticalthresholds.trunk.warning.15min.HighLaserBias
|
81.0 (%)
|
0.0, 0.1, 0.2 .. 100.0
|
TXP-MR-10G.opticalthresholds.trunk.warning.15min.HighRxPower
|
-7.5 (dBm)
|
LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0
|
TXP-MR-10G.opticalthresholds.trunk.warning.15min.HighTxPower
|
3.5 (dBm)
|
LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0
|
TXP-MR-10G.opticalthresholds.trunk.warning.15min.LowRxPower
|
-24.5 (dBm)
|
-40.0, -39.9, -39.8 .. HighRxPower
|
TXP-MR-10G.opticalthresholds.trunk.warning.15min.LowTxPower
|
2.5 (dBm)
|
-40.0, -39.9, -39.8 .. HighTxPower
|
TXP-MR-10G.opticalthresholds.trunk.warning.1day.HighLaserBias
|
85.5 (%)
|
0.0, 0.1, 0.2 .. 100.0
|
TXP-MR-10G.opticalthresholds.trunk.warning.1day.HighRxPower
|
-7.3 (dBm)
|
LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0
|
TXP-MR-10G.opticalthresholds.trunk.warning.1day.HighTxPower
|
3.7 (dBm)
|
LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0
|
TXP-MR-10G.opticalthresholds.trunk.warning.1day.LowRxPower
|
-24.7 (dBm)
|
-40.0, -39.9, -39.8 .. HighRxPower
|
TXP-MR-10G.opticalthresholds.trunk.warning.1day.LowTxPower
|
2.3 (dBm)
|
-40.0, -39.9, -39.8 .. HighTxPower
|
TXP-MR-10G.otn.fecthresholds.standard.15min.BitErrorsCorrected
|
903330 (count)
|
0-9033621811200
|
TXP-MR-10G.otn.fecthresholds.standard.15min.UncorrectableWords
|
5 (count)
|
0-4724697600
|
TXP-MR-10G.otn.fecthresholds.standard.1day.BitErrorsCorrected
|
86719680 (count)
|
0-867227693875200
|
TXP-MR-10G.otn.fecthresholds.standard.1day.UncorrectableWords
|
480 (count)
|
0-453570969600
|
TXP-MR-10G.otn.g709thresholds.pm.farend.15min.BBE
|
85040 (count)
|
0-8850600
|
TXP-MR-10G.otn.g709thresholds.pm.farend.15min.ES
|
87 (seconds)
|
0-900
|
TXP-MR-10G.otn.g709thresholds.pm.farend.15min.FC
|
10 (count)
|
0-72
|
TXP-MR-10G.otn.g709thresholds.pm.farend.15min.SES
|
1 (seconds)
|
0-900
|
TXP-MR-10G.otn.g709thresholds.pm.farend.15min.UAS
|
3 (seconds)
|
0-900
|
TXP-MR-10G.otn.g709thresholds.pm.farend.1day.BBE
|
850400 (count)
|
0-849657600
|
TXP-MR-10G.otn.g709thresholds.pm.farend.1day.ES
|
864 (seconds)
|
0-86400
|
TXP-MR-10G.otn.g709thresholds.pm.farend.1day.FC
|
40 (count)
|
0-6912
|
TXP-MR-10G.otn.g709thresholds.pm.farend.1day.SES
|
4 (seconds)
|
0-86400
|
TXP-MR-10G.otn.g709thresholds.pm.farend.1day.UAS
|
10 (seconds)
|
0-86400
|
TXP-MR-10G.otn.g709thresholds.pm.nearend.15min.BBE
|
85040 (count)
|
0-8850600
|
TXP-MR-10G.otn.g709thresholds.pm.nearend.15min.ES
|
87 (seconds)
|
0-900
|
TXP-MR-10G.otn.g709thresholds.pm.nearend.15min.FC
|
10 (count)
|
0-72
|
TXP-MR-10G.otn.g709thresholds.pm.nearend.15min.SES
|
1 (seconds)
|
0-900
|
TXP-MR-10G.otn.g709thresholds.pm.nearend.15min.UAS
|
3 (seconds)
|
0-900
|
TXP-MR-10G.otn.g709thresholds.pm.nearend.1day.BBE
|
850400 (count)
|
0-849657600
|
TXP-MR-10G.otn.g709thresholds.pm.nearend.1day.ES
|
864 (seconds)
|
0-86400
|
TXP-MR-10G.otn.g709thresholds.pm.nearend.1day.FC
|
40 (count)
|
0-6912
|
TXP-MR-10G.otn.g709thresholds.pm.nearend.1day.SES
|
4 (seconds)
|
0-86400
|
TXP-MR-10G.otn.g709thresholds.pm.nearend.1day.UAS
|
10 (seconds)
|
0-86400
|
TXP-MR-10G.otn.g709thresholds.sm.farend.15min.BBE
|
10000 (count)
|
0-8850600
|
TXP-MR-10G.otn.g709thresholds.sm.farend.15min.ES
|
500 (seconds)
|
0-900
|
TXP-MR-10G.otn.g709thresholds.sm.farend.15min.FC
|
10 (count)
|
0-72
|
TXP-MR-10G.otn.g709thresholds.sm.farend.15min.SES
|
500 (seconds)
|
0-900
|
TXP-MR-10G.otn.g709thresholds.sm.farend.15min.UAS
|
500 (seconds)
|
0-900
|
TXP-MR-10G.otn.g709thresholds.sm.farend.1day.BBE
|
100000 (count)
|
0-849657600
|
TXP-MR-10G.otn.g709thresholds.sm.farend.1day.ES
|
5000 (seconds)
|
0-86400
|
TXP-MR-10G.otn.g709thresholds.sm.farend.1day.FC
|
40 (count)
|
0-6912
|
TXP-MR-10G.otn.g709thresholds.sm.farend.1day.SES
|
5000 (seconds)
|
0-86400
|
TXP-MR-10G.otn.g709thresholds.sm.farend.1day.UAS
|
5000 (seconds)
|
0-86400
|
TXP-MR-10G.otn.g709thresholds.sm.nearend.15min.BBE
|
10000 (count)
|
0-8850600
|
TXP-MR-10G.otn.g709thresholds.sm.nearend.15min.ES
|
500 (seconds)
|
0-900
|
TXP-MR-10G.otn.g709thresholds.sm.nearend.15min.FC
|
10 (count)
|
0-72
|
TXP-MR-10G.otn.g709thresholds.sm.nearend.15min.SES
|
500 (seconds)
|
0-900
|
TXP-MR-10G.otn.g709thresholds.sm.nearend.15min.UAS
|
500 (seconds)
|
0-900
|
TXP-MR-10G.otn.g709thresholds.sm.nearend.1day.BBE
|
100000 (count)
|
0-849657600
|
TXP-MR-10G.otn.g709thresholds.sm.nearend.1day.ES
|
5000 (seconds)
|
0-86400
|
TXP-MR-10G.otn.g709thresholds.sm.nearend.1day.FC
|
40 (count)
|
0-6912
|
TXP-MR-10G.otn.g709thresholds.sm.nearend.1day.SES
|
5000 (seconds)
|
0-86400
|
TXP-MR-10G.otn.g709thresholds.sm.nearend.1day.UAS
|
5000 (seconds)
|
0-86400
|
TXP-MR-10G.otn.otnLines.FEC
|
Enable
|
•Disable, Enable when G709OTN is Enable
•Disable when G709OTN is Disable
|
TXP-MR-10G.otn.otnLines.G709OTN
|
Enable
|
Disable, Enable
|
TXP-MR-10G.otn.otnLines.SDBER
|
1E-7
|
1E-5, 1E-6, 1E-7, 1E-8, 1E-9
|
TXP-MR-10G.pmthresholds.client.ms.farend.15min.BBE
|
85040 (count)
|
0-8850600
|
TXP-MR-10G.pmthresholds.client.ms.farend.15min.EB
|
85040 (count)
|
0-8850600
|
TXP-MR-10G.pmthresholds.client.ms.farend.15min.ES
|
87 (seconds)
|
0-900
|
TXP-MR-10G.pmthresholds.client.ms.farend.15min.SES
|
1 (seconds)
|
0-900
|
TXP-MR-10G.pmthresholds.client.ms.farend.15min.UAS
|
3 (seconds)
|
0-900
|
TXP-MR-10G.pmthresholds.client.ms.farend.1day.BBE
|
850400 (count)
|
0-849657600
|
TXP-MR-10G.pmthresholds.client.ms.farend.1day.EB
|
850400 (count)
|
0-849657600
|
TXP-MR-10G.pmthresholds.client.ms.farend.1day.ES
|
864 (seconds)
|
0-86400
|
TXP-MR-10G.pmthresholds.client.ms.farend.1day.SES
|
4 (seconds)
|
0-86400
|
TXP-MR-10G.pmthresholds.client.ms.farend.1day.UAS
|
10 (seconds)
|
0-86400
|
TXP-MR-10G.pmthresholds.client.ms.nearend.15min.BBE
|
85040 (count)
|
0-8850600
|
TXP-MR-10G.pmthresholds.client.ms.nearend.15min.EB
|
85040 (count)
|
0-8850600
|
TXP-MR-10G.pmthresholds.client.ms.nearend.15min.ES
|
87 (seconds)
|
0-900
|
TXP-MR-10G.pmthresholds.client.ms.nearend.15min.SES
|
1 (seconds)
|
0-900
|
TXP-MR-10G.pmthresholds.client.ms.nearend.15min.UAS
|
3 (seconds)
|
0-900
|
TXP-MR-10G.pmthresholds.client.ms.nearend.1day.BBE
|
850400 (count)
|
0-849657600
|
TXP-MR-10G.pmthresholds.client.ms.nearend.1day.EB
|
850400 (count)
|
0-849657600
|
TXP-MR-10G.pmthresholds.client.ms.nearend.1day.ES
|
864 (seconds)
|
0-86400
|
TXP-MR-10G.pmthresholds.client.ms.nearend.1day.SES
|
4 (seconds)
|
0-86400
|
TXP-MR-10G.pmthresholds.client.ms.nearend.1day.UAS
|
10 (seconds)
|
0-86400
|
TXP-MR-10G.pmthresholds.client.rs.nearend.15min.BBE
|
10000 (count)
|
0-8850600
|
TXP-MR-10G.pmthresholds.client.rs.nearend.15min.EB
|
10000 (count)
|
0-7967700
|
TXP-MR-10G.pmthresholds.client.rs.nearend.15min.ES
|
500 (seconds)
|
0-900
|
TXP-MR-10G.pmthresholds.client.rs.nearend.15min.SES
|
500 (seconds)
|
0-900
|
TXP-MR-10G.pmthresholds.client.rs.nearend.15min.UAS
|
3 (seconds)
|
0-900
|
TXP-MR-10G.pmthresholds.client.rs.nearend.1day.BBE
|
100000 (count)
|
0-849657600
|
TXP-MR-10G.pmthresholds.client.rs.nearend.1day.EB
|
100000 (count)
|
0-764899200
|
TXP-MR-10G.pmthresholds.client.rs.nearend.1day.ES
|
5000 (seconds)
|
0-86400
|
TXP-MR-10G.pmthresholds.client.rs.nearend.1day.SES
|
5000 (seconds)
|
0-86400
|
TXP-MR-10G.pmthresholds.client.rs.nearend.1day.UAS
|
10 (seconds)
|
0-86400
|
TXP-MR-10G.pmthresholds.trunk.ms.farend.15min.BBE
|
85040 (count)
|
0-8850600
|
TXP-MR-10G.pmthresholds.trunk.ms.farend.15min.EB
|
85040 (count)
|
0-8850600
|
TXP-MR-10G.pmthresholds.trunk.ms.farend.15min.ES
|
87 (seconds)
|
0-900
|
TXP-MR-10G.pmthresholds.trunk.ms.farend.15min.SES
|
1 (seconds)
|
0-900
|
TXP-MR-10G.pmthresholds.trunk.ms.farend.15min.UAS
|
3 (seconds)
|
0-900
|
TXP-MR-10G.pmthresholds.trunk.ms.farend.1day.BBE
|
850400 (count)
|
0-849657600
|
TXP-MR-10G.pmthresholds.trunk.ms.farend.1day.EB
|
850400 (count)
|
0-849657600
|
TXP-MR-10G.pmthresholds.trunk.ms.farend.1day.ES
|
864 (seconds)
|
0-86400
|
TXP-MR-10G.pmthresholds.trunk.ms.farend.1day.SES
|
4 (seconds)
|
0-86400
|
TXP-MR-10G.pmthresholds.trunk.ms.farend.1day.UAS
|
10 (seconds)
|
0-86400
|
TXP-MR-10G.pmthresholds.trunk.ms.nearend.15min.BBE
|
85040 (count)
|
0-8850600
|
TXP-MR-10G.pmthresholds.trunk.ms.nearend.15min.EB
|
85040 (count)
|
0-8850600
|
TXP-MR-10G.pmthresholds.trunk.ms.nearend.15min.ES
|
87 (seconds)
|
0-900
|
TXP-MR-10G.pmthresholds.trunk.ms.nearend.15min.SES
|
1 (seconds)
|
0-900
|
TXP-MR-10G.pmthresholds.trunk.ms.nearend.15min.UAS
|
3 (seconds)
|
0-900
|
TXP-MR-10G.pmthresholds.trunk.ms.nearend.1day.BBE
|
850400 (count)
|
0-849657600
|
TXP-MR-10G.pmthresholds.trunk.ms.nearend.1day.EB
|
850400 (count)
|
0-849657600
|
TXP-MR-10G.pmthresholds.trunk.ms.nearend.1day.ES
|
864 (seconds)
|
0-86400
|
TXP-MR-10G.pmthresholds.trunk.ms.nearend.1day.SES
|
4 (seconds)
|
0-86400
|
TXP-MR-10G.pmthresholds.trunk.ms.nearend.1day.UAS
|
10 (seconds)
|
0-86400
|
TXP-MR-10G.pmthresholds.trunk.rs.nearend.15min.BBE
|
10000 (count)
|
0-8850600
|
TXP-MR-10G.pmthresholds.trunk.rs.nearend.15min.EB
|
10000 (count)
|
0-7967700
|
TXP-MR-10G.pmthresholds.trunk.rs.nearend.15min.ES
|
500 (seconds)
|
0-900
|
TXP-MR-10G.pmthresholds.trunk.rs.nearend.15min.SES
|
500 (seconds)
|
0-900
|
TXP-MR-10G.pmthresholds.trunk.rs.nearend.15min.UAS
|
3 (seconds)
|
0-900
|
TXP-MR-10G.pmthresholds.trunk.rs.nearend.1day.BBE
|
100000 (count)
|
0-849657600
|
TXP-MR-10G.pmthresholds.trunk.rs.nearend.1day.EB
|
100000 (count)
|
0-764899200
|
TXP-MR-10G.pmthresholds.trunk.rs.nearend.1day.ES
|
5000 (seconds)
|
0-86400
|
TXP-MR-10G.pmthresholds.trunk.rs.nearend.1day.SES
|
5000 (seconds)
|
0-86400
|
TXP-MR-10G.pmthresholds.trunk.rs.nearend.1day.UAS
|
10 (seconds)
|
0-86400
|
D.3.1.7 TXP_MR_2.5G Card Default Settings
Table D-19 lists the TXP_MR_2.5G card default settings.
Table D-19 TXP_MR_2.5G Card Default Settings (ETSI)
Default Name
|
Default Value
|
Default Domain
|
TXP-MR-2_5G.config.client.AINSSoakTime
|
08:00 (hours:mins)
|
00:00, 00:15, 00:30 .. 48:00
|
TXP-MR-2_5G.config.client.AlsMode
|
Disabled
|
Disabled, Auto Restart, Manual Restart, Manual Restart for Test
|
TXP-MR-2_5G.config.client.AlsRecoveryPulseDuration
|
40.0 (seconds)
|
•2.0, 2.1, 2.2 .. 100.0 when AlsMode is Disabled, Auto Restart, Manual Restart
•80.0, 80.1, 80.2 .. 100.0 when AlsMode is Manual Restart for Test
|
TXP-MR-2_5G.config.client.AlsRecoveryPulseInterval
|
100 (seconds)
|
60-300
|
TXP-MR-2_5G.config.client.ppmPortAssignment
|
UNASSIGNED
|
UNASSIGNED, STM1_PORT, STM4_PORT, STM16_PORT, ONE_GE_PORT, ESCON_PORT, DV6000_PORT, SDI_D1_VIDEO_PORT, HDTV_PORT, PASS_THRU_PORT, ETR_CLO_PORT, ISC compat, FC1G_PORT, FC2G_PORT, FICON1G_PORT, FICON2G_PORT, ISC peer
|
TXP-MR-2_5G.config.client.ppmSlotAssignment
|
UNASSIGNED
|
UNASSIGNED, PPM (1 Port)
|
TXP-MR-2_5G.config.client.SDBER
|
1E-7
|
1E-5, 1E-6, 1E-7, 1E-8, 1E-9
|
TXP-MR-2_5G.config.client.SFBER
|
1E-4
|
1E-3, 1E-4, 1E-5
|
TXP-MR-2_5G.config.client.TerminationMode
|
Transparent
|
•Transparent, Regeneration Section, Multiplex Section when ppmPortAssignment is UNASSIGNED, STM1_PORT, STM4_PORT, STM16_PORT
•Transparent when ppmPortAssignment is STM1_PORT, STM4_PORT, STM16_PORT, ONE_GE_PORT, ESCON_PORT, DV6000_PORT, SDI_D1_VIDEO_PORT, HDTV_PORT, PASS_THRU_PORT, ETR_CLO_PORT, ISC compat, FC1G_PORT, FC2G_PORT, FICON1G_PORT, FICON2G_PORT, ISC peer
|
TXP-MR-2_5G.config.trunk.AINSSoakTime
|
08:00 (hours:mins)
|
00:00, 00:15, 00:30 .. 48:00
|
TXP-MR-2_5G.config.trunk.AlsMode
|
Disabled
|
Disabled, Auto Restart, Manual Restart, Manual Restart for Test
|
TXP-MR-2_5G.config.trunk.AlsRecoveryPulseDuration
|
40.0 (seconds)
|
•2.0, 2.1, 2.2 .. 100.0 when AlsMode is Disabled, Auto Restart, Manual Restart
•80.0, 80.1, 80.2 .. 100.0 when AlsMode is Manual Restart for Test
|
TXP-MR-2_5G.config.trunk.AlsRecoveryPulseInterval
|
100 (seconds)
|
60-300
|
TXP-MR-2_5G.config.trunk.SDBER
|
1E-7
|
1E-5, 1E-6, 1E-7, 1E-8, 1E-9
|
TXP-MR-2_5G.config.trunk.SFBER
|
1E-4
|
1E-3, 1E-4, 1E-5
|
TXP-MR-2_5G.opticalthresholds.client.alarm.HighLaserBias
|
90.0 (%)
|
0.0, 0.1, 0.2 .. 100.0
|
TXP-MR-2_5G.opticalthresholds.client.alarm.HighRxPower
|
3.0 (dBm)
|
LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0
|
TXP-MR-2_5G.opticalthresholds.client.alarm.HighTxPower
|
3.0 (dBm)
|
LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0
|
TXP-MR-2_5G.opticalthresholds.client.alarm.LowRxPower
|
-21.0 (dBm)
|
-40.0, -39.9, -39.8 .. HighRxPower
|
TXP-MR-2_5G.opticalthresholds.client.alarm.LowTxPower
|
-15.0 (dBm)
|
-40.0, -39.9, -39.8 .. HighTxPower
|
TXP-MR-2_5G.opticalthresholds.client.warning.15min.HighLaserBias
|
81.0 (%)
|
0.0, 0.1, 0.2 .. 100.0
|
TXP-MR-2_5G.opticalthresholds.client.warning.15min.HighRxPower
|
2.0 (dBm)
|
LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0
|
TXP-MR-2_5G.opticalthresholds.client.warning.15min.HighTxPower
|
2.0 (dBm)
|
LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0
|
TXP-MR-2_5G.opticalthresholds.client.warning.15min.LowRxPower
|
-20.0 (dBm)
|
-40.0, -39.9, -39.8 .. HighRxPower
|
TXP-MR-2_5G.opticalthresholds.client.warning.15min.LowTxPower
|
-7.0 (dBm)
|
-40.0, -39.9, -39.8 .. HighTxPower
|
TXP-MR-2_5G.opticalthresholds.client.warning.1day.HighLaserBias
|
85.5 (%)
|
0.0, 0.1, 0.2 .. 100.0
|
TXP-MR-2_5G.opticalthresholds.client.warning.1day.HighRxPower
|
2.5 (dBm)
|
LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0
|
TXP-MR-2_5G.opticalthresholds.client.warning.1day.HighTxPower
|
2.5 (dBm)
|
LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0
|
TXP-MR-2_5G.opticalthresholds.client.warning.1day.LowRxPower
|
-20.5 (dBm)
|
-40.0, -39.9, -39.8 .. HighRxPower
|
TXP-MR-2_5G.opticalthresholds.client.warning.1day.LowTxPower
|
-7.5 (dBm)
|
-40.0, -39.9, -39.8 .. HighTxPower
|
TXP-MR-2_5G.opticalthresholds.trunk.alarm.HighLaserBias
|
98.0 (%)
|
0.0, 0.1, 0.2 .. 100.0
|
TXP-MR-2_5G.opticalthresholds.trunk.alarm.HighRxPower
|
-8.0 (dBrn)
|
LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0
|
TXP-MR-2_5G.opticalthresholds.trunk.alarm.LowRxPower
|
-25.0 (dBrn)
|
-40.0, -39.9, -39.8 .. HighRxPower
|
TXP-MR-2_5G.opticalthresholds.trunk.warning.15min.HighLaserBias
|
95.0 (%)
|
0.0, 0.1, 0.2 .. 100.0
|
TXP-MR-2_5G.opticalthresholds.trunk.warning.15min.HighRxPower
|
-7.5 (dBrn)
|
LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0
|
TXP-MR-2_5G.opticalthresholds.trunk.warning.15min.LowRxPower
|
-24.5 (dBrn)
|
-40.0, -39.9, -39.8 .. HighRxPower
|
TXP-MR-2_5G.opticalthresholds.trunk.warning.1day.HighLaserBias
|
96.0 (%)
|
0.0, 0.1, 0.2 .. 100.0
|
TXP-MR-2_5G.opticalthresholds.trunk.warning.1day.HighRxPower
|
-7.3 (dBrn)
|
LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0
|
TXP-MR-2_5G.opticalthresholds.trunk.warning.1day.LowRxPower
|
-24.7 (dBrn)
|
-40.0, -39.9, -39.8 .. HighRxPower
|
TXP-MR-2_5G.otn.fecthresholds.1gethernet.15min.BitErrorsCorrected
|
112500 (count)
|
0-9033621811200
|
TXP-MR-2_5G.otn.fecthresholds.1gethernet.15min.UncorrectableWords
|
1 (count)
|
0-4724697600
|
TXP-MR-2_5G.otn.fecthresholds.1gethernet.1day.BitErrorsCorrected
|
10800000 (count)
|
0-867227693875200
|
TXP-MR-2_5G.otn.fecthresholds.1gethernet.1day.UncorrectableWords
|
96 (count)
|
0-453570969600
|
TXP-MR-2_5G.otn.fecthresholds.1gfiberchannel.15min.BitErrorsCorrected
|
90000 (count)
|
0-9033621811200
|
TXP-MR-2_5G.otn.fecthresholds.1gfiberchannel.15min.UncorrectableWords
|
1 (count)
|
0-4724697600
|
TXP-MR-2_5G.otn.fecthresholds.1gfiberchannel.1day.BitErrorsCorrected
|
8640000 (count)
|
0-867227693875200
|
TXP-MR-2_5G.otn.fecthresholds.1gfiberchannel.1day.UncorrectableWords
|
96 (count)
|
0-453570969600
|
TXP-MR-2_5G.otn.fecthresholds.1gficon.15min.BitErrorsCorrected
|
90000 (count)
|
0-9033621811200
|
TXP-MR-2_5G.otn.fecthresholds.1gficon.15min.UncorrectableWords
|
1 (count)
|
0-4724697600
|
TXP-MR-2_5G.otn.fecthresholds.1gficon.1day.BitErrorsCorrected
|
8640000 (count)
|
0-867227693875200
|
TXP-MR-2_5G.otn.fecthresholds.1gficon.1day.UncorrectableWords
|
96 (count)
|
0-453570969600
|
TXP-MR-2_5G.otn.fecthresholds.2gfiberchannel.15min.BitErrorsCorrected
|
180900 (count)
|
0-9033621811200
|
TXP-MR-2_5G.otn.fecthresholds.2gfiberchannel.15min.UncorrectableWords
|
1 (count)
|
0-4724697600
|
TXP-MR-2_5G.otn.fecthresholds.2gfiberchannel.1day.BitErrorsCorrected
|
17366400 (count)
|
0-867227693875200
|
TXP-MR-2_5G.otn.fecthresholds.2gfiberchannel.1day.UncorrectableWords
|
96 (count)
|
0-453570969600
|
TXP-MR-2_5G.otn.fecthresholds.2gficon.15min.BitErrorsCorrected
|
180900 (count)
|
0-9033621811200
|
TXP-MR-2_5G.otn.fecthresholds.2gficon.15min.UncorrectableWords
|
1 (count)
|
0-4724697600
|
TXP-MR-2_5G.otn.fecthresholds.2gficon.1day.BitErrorsCorrected
|
17366400 (count)
|
0-867227693875200
|
TXP-MR-2_5G.otn.fecthresholds.2gficon.1day.UncorrectableWords
|
96 (count)
|
0-453570969600
|
TXP-MR-2_5G.otn.fecthresholds.stm1.15min.BitErrorsCorrected
|
15012 (count)
|
0-9033621811200
|
TXP-MR-2_5G.otn.fecthresholds.stm1.15min.UncorrectableWords
|
1 (count)
|
0-4724697600
|
TXP-MR-2_5G.otn.fecthresholds.stm1.1day.BitErrorsCorrected
|
1441152 (count)
|
0-867227693875200
|
TXP-MR-2_5G.otn.fecthresholds.stm1.1day.UncorrectableWords
|
96 (count)
|
0-453570969600
|
TXP-MR-2_5G.otn.fecthresholds.stm16.15min.BitErrorsCorrected
|
225837 (count)
|
0-9033621811200
|
TXP-MR-2_5G.otn.fecthresholds.stm16.15min.UncorrectableWords
|
1 (count)
|
0-4724697600
|
TXP-MR-2_5G.otn.fecthresholds.stm16.1day.BitErrorsCorrected
|
21680352 (count)
|
0-867227693875200
|
TXP-MR-2_5G.otn.fecthresholds.stm16.1day.UncorrectableWords
|
96 (count)
|
0-453570969600
|
TXP-MR-2_5G.otn.fecthresholds.stm4.15min.BitErrorsCorrected
|
56457 (count)
|
0-9033621811200
|
TXP-MR-2_5G.otn.fecthresholds.stm4.15min.UncorrectableWords
|
1 (count)
|
0-4724697600
|
TXP-MR-2_5G.otn.fecthresholds.stm4.1day.BitErrorsCorrected
|
5419872 (count)
|
0-867227693875200
|
TXP-MR-2_5G.otn.fecthresholds.stm4.1day.UncorrectableWords
|
96 (count)
|
0-453570969600
|
TXP-MR-2_5G.otn.g709thresholds.pm.farend.15min.BBE
|
21260 (count)
|
0-8850600
|
TXP-MR-2_5G.otn.g709thresholds.pm.farend.15min.ES
|
87 (seconds)
|
0-900
|
TXP-MR-2_5G.otn.g709thresholds.pm.farend.15min.FC
|
10 (count)
|
0-72
|
TXP-MR-2_5G.otn.g709thresholds.pm.farend.15min.SES
|
1 (seconds)
|
0-900
|
TXP-MR-2_5G.otn.g709thresholds.pm.farend.15min.UAS
|
3 (seconds)
|
0-900
|
TXP-MR-2_5G.otn.g709thresholds.pm.farend.1day.BBE
|
212600 (count)
|
0-849657600
|
TXP-MR-2_5G.otn.g709thresholds.pm.farend.1day.ES
|
864 (seconds)
|
0-86400
|
TXP-MR-2_5G.otn.g709thresholds.pm.farend.1day.FC
|
40 (count)
|
0-6912
|
TXP-MR-2_5G.otn.g709thresholds.pm.farend.1day.SES
|
4 (seconds)
|
0-86400
|
TXP-MR-2_5G.otn.g709thresholds.pm.farend.1day.UAS
|
10 (seconds)
|
0-86400
|
TXP-MR-2_5G.otn.g709thresholds.pm.nearend.15min.BBE
|
21260 (count)
|
0-8850600
|
TXP-MR-2_5G.otn.g709thresholds.pm.nearend.15min.ES
|
87 (seconds)
|
0-900
|
TXP-MR-2_5G.otn.g709thresholds.pm.nearend.15min.FC
|
10 (count)
|
0-72
|
TXP-MR-2_5G.otn.g709thresholds.pm.nearend.15min.SES
|
1 (seconds)
|
0-900
|
TXP-MR-2_5G.otn.g709thresholds.pm.nearend.15min.UAS
|
3 (seconds)
|
0-900
|
TXP-MR-2_5G.otn.g709thresholds.pm.nearend.1day.BBE
|
212600 (count)
|
0-849657600
|
TXP-MR-2_5G.otn.g709thresholds.pm.nearend.1day.ES
|
864 (seconds)
|
0-86400
|
TXP-MR-2_5G.otn.g709thresholds.pm.nearend.1day.FC
|
40 (count)
|
0-6912
|
TXP-MR-2_5G.otn.g709thresholds.pm.nearend.1day.SES
|
4 (seconds)
|
0-86400
|
TXP-MR-2_5G.otn.g709thresholds.pm.nearend.1day.UAS
|
10 (seconds)
|
0-86400
|
TXP-MR-2_5G.otn.g709thresholds.sm.farend.15min.BBE
|
10000 (count)
|
0-8850600
|
TXP-MR-2_5G.otn.g709thresholds.sm.farend.15min.ES
|
500 (seconds)
|
0-900
|
TXP-MR-2_5G.otn.g709thresholds.sm.farend.15min.FC
|
10 (count)
|
0-72
|
TXP-MR-2_5G.otn.g709thresholds.sm.farend.15min.SES
|
500 (seconds)
|
0-900
|
TXP-MR-2_5G.otn.g709thresholds.sm.farend.15min.UAS
|
500 (seconds)
|
0-900
|
TXP-MR-2_5G.otn.g709thresholds.sm.farend.1day.BBE
|
100000 (count)
|
0-849657600
|
TXP-MR-2_5G.otn.g709thresholds.sm.farend.1day.ES
|
5000 (seconds)
|
0-86400
|
TXP-MR-2_5G.otn.g709thresholds.sm.farend.1day.FC
|
40 (count)
|
0-6912
|
TXP-MR-2_5G.otn.g709thresholds.sm.farend.1day.SES
|
5000 (seconds)
|
0-86400
|
TXP-MR-2_5G.otn.g709thresholds.sm.farend.1day.UAS
|
5000 (seconds)
|
0-86400
|
TXP-MR-2_5G.otn.g709thresholds.sm.nearend.15min.BBE
|
10000 (count)
|
0-8850600
|
TXP-MR-2_5G.otn.g709thresholds.sm.nearend.15min.ES
|
500 (seconds)
|
0-900
|
TXP-MR-2_5G.otn.g709thresholds.sm.nearend.15min.FC
|
10 (count)
|
0-72
|
TXP-MR-2_5G.otn.g709thresholds.sm.nearend.15min.SES
|
500 (seconds)
|
0-900
|
TXP-MR-2_5G.otn.g709thresholds.sm.nearend.15min.UAS
|
500 (seconds)
|
0-900
|
TXP-MR-2_5G.otn.g709thresholds.sm.nearend.1day.BBE
|
100000 (count)
|
0-849657600
|
TXP-MR-2_5G.otn.g709thresholds.sm.nearend.1day.ES
|
5000 (seconds)
|
0-86400
|
TXP-MR-2_5G.otn.g709thresholds.sm.nearend.1day.FC
|
40 (count)
|
0-6912
|
TXP-MR-2_5G.otn.g709thresholds.sm.nearend.1day.SES
|
5000 (seconds)
|
0-86400
|
TXP-MR-2_5G.otn.g709thresholds.sm.nearend.1day.UAS
|
5000 (seconds)
|
0-86400
|
TXP-MR-2_5G.otn.otnLines.FEC
|
Enable
|
•Disable, Enable when G709OTN is Enable
•Disable when G709OTN is Disable
|
TXP-MR-2_5G.otn.otnLines.G709OTN
|
Enable
|
Disable, Enable
|
TXP-MR-2_5G.otn.otnLines.SDBER
|
1E-7
|
1E-5, 1E-6, 1E-7, 1E-8, 1E-9
|
TXP-MR-2_5G.pmthresholds.stm1.ms.farend.15min.BBE
|
1312 (count)
|
0-137700
|
TXP-MR-2_5G.pmthresholds.stm1.ms.farend.15min.EB
|
1312 (count)
|
0-137700
|
TXP-MR-2_5G.pmthresholds.stm1.ms.farend.15min.ES
|
87 (seconds)
|
0-900
|
TXP-MR-2_5G.pmthresholds.stm1.ms.farend.15min.SES
|
1 (seconds)
|
0-900
|
TXP-MR-2_5G.pmthresholds.stm1.ms.farend.15min.UAS
|
3 (seconds)
|
0-900
|
TXP-MR-2_5G.pmthresholds.stm1.ms.farend.1day.BBE
|
13120 (count)
|
0-13219200
|
TXP-MR-2_5G.pmthresholds.stm1.ms.farend.1day.EB
|
13120 (count)
|
0-13219200
|
TXP-MR-2_5G.pmthresholds.stm1.ms.farend.1day.ES
|
864 (seconds)
|
0-86400
|
TXP-MR-2_5G.pmthresholds.stm1.ms.farend.1day.SES
|
4 (seconds)
|
0-86400
|
TXP-MR-2_5G.pmthresholds.stm1.ms.farend.1day.UAS
|
10 (seconds)
|
0-86400
|
TXP-MR-2_5G.pmthresholds.stm1.ms.nearend.15min.BBE
|
1312 (count)
|
0-137700
|
TXP-MR-2_5G.pmthresholds.stm1.ms.nearend.15min.EB
|
1312 (count)
|
0-137700
|
TXP-MR-2_5G.pmthresholds.stm1.ms.nearend.15min.ES
|
87 (seconds)
|
0-900
|
TXP-MR-2_5G.pmthresholds.stm1.ms.nearend.15min.SES
|
1 (seconds)
|
0-900
|
TXP-MR-2_5G.pmthresholds.stm1.ms.nearend.15min.UAS
|
3 (seconds)
|
0-900
|
TXP-MR-2_5G.pmthresholds.stm1.ms.nearend.1day.BBE
|
13120 (count)
|
0-13219200
|
TXP-MR-2_5G.pmthresholds.stm1.ms.nearend.1day.EB
|
13120 (count)
|
0-13219200
|
TXP-MR-2_5G.pmthresholds.stm1.ms.nearend.1day.ES
|
864 (seconds)
|
0-86400
|
TXP-MR-2_5G.pmthresholds.stm1.ms.nearend.1day.SES
|
4 (seconds)
|
0-86400
|
TXP-MR-2_5G.pmthresholds.stm1.ms.nearend.1day.UAS
|
10 (seconds)
|
0-86400
|
TXP-MR-2_5G.pmthresholds.stm1.rs.nearend.15min.BBE
|
10000 (count)
|
0-138600
|
TXP-MR-2_5G.pmthresholds.stm1.rs.nearend.15min.EB
|
10000 (count)
|
0-138600
|
TXP-MR-2_5G.pmthresholds.stm1.rs.nearend.15min.ES
|
500 (seconds)
|
0-900
|
TXP-MR-2_5G.pmthresholds.stm1.rs.nearend.15min.SES
|
500 (seconds)
|
0-900
|
TXP-MR-2_5G.pmthresholds.stm1.rs.nearend.15min.UAS
|
3 (seconds)
|
0-900
|
TXP-MR-2_5G.pmthresholds.stm1.rs.nearend.1day.BBE
|
10000 (count)
|
0-13305600
|
TXP-MR-2_5G.pmthresholds.stm1.rs.nearend.1day.EB
|
100000 (count)
|
0-13305600
|
TXP-MR-2_5G.pmthresholds.stm1.rs.nearend.1day.ES
|
5000 (seconds)
|
0-86400
|
TXP-MR-2_5G.pmthresholds.stm1.rs.nearend.1day.SES
|
5000 (seconds)
|
0-86400
|
TXP-MR-2_5G.pmthresholds.stm1.rs.nearend.1day.UAS
|
10 (seconds)
|
0-86400
|
TXP-MR-2_5G.pmthresholds.stm16.ms.farend.15min.BBE
|
21260 (count)
|
0-2212200
|
TXP-MR-2_5G.pmthresholds.stm16.ms.farend.15min.EB
|
21260 (count)
|
0-2212200
|
TXP-MR-2_5G.pmthresholds.stm16.ms.farend.15min.ES
|
87 (seconds)
|
0-900
|
TXP-MR-2_5G.pmthresholds.stm16.ms.farend.15min.SES
|
1 (seconds)
|
0-900
|
TXP-MR-2_5G.pmthresholds.stm16.ms.farend.15min.UAS
|
3 (seconds)
|
0-900
|
TXP-MR-2_5G.pmthresholds.stm16.ms.farend.1day.BBE
|
212600 (count)
|
0-212371200
|
TXP-MR-2_5G.pmthresholds.stm16.ms.farend.1day.EB
|
212600 (seconds)
|
0-212371200
|
TXP-MR-2_5G.pmthresholds.stm16.ms.farend.1day.ES
|
864 (seconds)
|
0-900
|
TXP-MR-2_5G.pmthresholds.stm16.ms.farend.1day.SES
|
4 (seconds)
|
0-86400
|
TXP-MR-2_5G.pmthresholds.stm16.ms.farend.1day.UAS
|
10 (seconds)
|
0-86400
|
TXP-MR-2_5G.pmthresholds.stm16.ms.nearend.15min.BBE
|
21260 (count)
|
0-2212200
|
TXP-MR-2_5G.pmthresholds.stm16.ms.nearend.15min.EB
|
21260 (count)
|
0-2212200
|
TXP-MR-2_5G.pmthresholds.stm16.ms.nearend.15min.ES
|
87 (seconds)
|
0-900
|
TXP-MR-2_5G.pmthresholds.stm16.ms.nearend.15min.SES
|
1 (seconds)
|
0-900
|
TXP-MR-2_5G.pmthresholds.stm16.ms.nearend.15min.UAS
|
3 (seconds)
|
0-900
|
TXP-MR-2_5G.pmthresholds.stm16.ms.nearend.1day.BBE
|
212600 (count)
|
0-212371200
|
TXP-MR-2_5G.pmthresholds.stm16.ms.nearend.1day.EB
|
212600 (count)
|
0-212371200
|
TXP-MR-2_5G.pmthresholds.stm16.ms.nearend.1day.ES
|
864 (seconds)
|
0-86400
|
TXP-MR-2_5G.pmthresholds.stm16.ms.nearend.1day.SES
|
4 (seconds)
|
0-86400
|
TXP-MR-2_5G.pmthresholds.stm16.ms.nearend.1day.UAS
|
10 (seconds)
|
0-86400
|
TXP-MR-2_5G.pmthresholds.stm16.rs.nearend.15min.BBE
|
10000 (count)
|
0-2151900
|
TXP-MR-2_5G.pmthresholds.stm16.rs.nearend.15min.EB
|
10000 (count)
|
0-2151900
|
TXP-MR-2_5G.pmthresholds.stm16.rs.nearend.15min.ES
|
500 (seconds)
|
0-900
|
TXP-MR-2_5G.pmthresholds.stm16.rs.nearend.15min.SES
|
500 (seconds)
|
0-900
|
TXP-MR-2_5G.pmthresholds.stm16.rs.nearend.15min.UAS
|
3 (seconds)
|
0-900
|
TXP-MR-2_5G.pmthresholds.stm16.rs.nearend.1day.BBE
|
10000 (count)
|
0-206582400
|
TXP-MR-2_5G.pmthresholds.stm16.rs.nearend.1day.EB
|
100000 (count)
|
0-206582400
|
TXP-MR-2_5G.pmthresholds.stm16.rs.nearend.1day.ES
|
5000 (seconds)
|
0-86400
|
TXP-MR-2_5G.pmthresholds.stm16.rs.nearend.1day.SES
|
5000 (seconds)
|
0-86400
|
TXP-MR-2_5G.pmthresholds.stm16.rs.nearend.1day.UAS
|
10 (seconds)
|
0-86400
|
TXP-MR-2_5G.pmthresholds.stm4.ms.farend.15min.BBE
|
5315 (count)
|
0-552600
|
TXP-MR-2_5G.pmthresholds.stm4.ms.farend.15min.EB
|
5315 (count)
|
0-552600
|
TXP-MR-2_5G.pmthresholds.stm4.ms.farend.15min.ES
|
87 (seconds)
|
0-900
|
TXP-MR-2_5G.pmthresholds.stm4.ms.farend.15min.SES
|
1 (seconds)
|
0-900
|
TXP-MR-2_5G.pmthresholds.stm4.ms.farend.15min.UAS
|
3 (seconds)
|
0-900
|
TXP-MR-2_5G.pmthresholds.stm4.ms.farend.1day.BBE
|
53150 (count)
|
0-53049600
|
TXP-MR-2_5G.pmthresholds.stm4.ms.farend.1day.EB
|
53150 (count)
|
0-53049600
|
TXP-MR-2_5G.pmthresholds.stm4.ms.farend.1day.ES
|
864 (seconds)
|
0-86400
|
TXP-MR-2_5G.pmthresholds.stm4.ms.farend.1day.SES
|
4 (seconds)
|
0-86400
|
TXP-MR-2_5G.pmthresholds.stm4.ms.farend.1day.UAS
|
10 (seconds)
|
0-86400
|
TXP-MR-2_5G.pmthresholds.stm4.ms.nearend.15min.BBE
|
5315 (count)
|
0-552600
|
TXP-MR-2_5G.pmthresholds.stm4.ms.nearend.15min.EB
|
5315 (count)
|
0-552600
|
TXP-MR-2_5G.pmthresholds.stm4.ms.nearend.15min.ES
|
87 (seconds)
|
0-900
|
TXP-MR-2_5G.pmthresholds.stm4.ms.nearend.15min.SES
|
1 (seconds)
|
0-900
|
TXP-MR-2_5G.pmthresholds.stm4.ms.nearend.15min.UAS
|
3 (seconds)
|
0-900
|
TXP-MR-2_5G.pmthresholds.stm4.ms.nearend.1day.BBE
|
53150 (count)
|
0-53049600
|
TXP-MR-2_5G.pmthresholds.stm4.ms.nearend.1day.EB
|
53150 (count)
|
0-53049600
|
TXP-MR-2_5G.pmthresholds.stm4.ms.nearend.1day.ES
|
864 (seconds)
|
0-86400
|
TXP-MR-2_5G.pmthresholds.stm4.ms.nearend.1day.SES
|
4 (seconds)
|
0-86400
|
TXP-MR-2_5G.pmthresholds.stm4.ms.nearend.1day.UAS
|
10 (seconds)
|
0-86400
|
TXP-MR-2_5G.pmthresholds.stm4.rs.nearend.15min.BBE
|
10000 (count)
|
0-553500
|
TXP-MR-2_5G.pmthresholds.stm4.rs.nearend.15min.EB
|
10000 (count)
|
0-553500
|
TXP-MR-2_5G.pmthresholds.stm4.rs.nearend.15min.ES
|
500 (seconds)
|
0-900
|
TXP-MR-2_5G.pmthresholds.stm4.rs.nearend.15min.SES
|
500 (seconds)
|
0-900
|
TXP-MR-2_5G.pmthresholds.stm4.rs.nearend.15min.UAS
|
3 (seconds)
|
0-900
|
TXP-MR-2_5G.pmthresholds.stm4.rs.nearend.1day.BBE
|
10000 (count)
|
0-53136000
|
TXP-MR-2_5G.pmthresholds.stm4.rs.nearend.1day.EB
|
100000 (count)
|
0-53136000
|
TXP-MR-2_5G.pmthresholds.stm4.rs.nearend.1day.ES
|
5000 (seconds)
|
0-86400
|
TXP-MR-2_5G.pmthresholds.stm4.rs.nearend.1day.SES
|
5000 (seconds)
|
0-86400
|
TXP-MR-2_5G.pmthresholds.stm4.rs.nearend.1day.UAS
|
10 (seconds)
|
0-86400
|
D.3.1.8 TXPP_MR_2.5G Card Default Settings
Table D-20 lists the TXPP_MR_2.5G card default settings.
Table D-20 TXPP-MR-2.5G Card Default Settings (ETSI)
Default Name
|
Default Value
|
Default Domain
|
TXPP-MR-2_5G.config.client.AINSSoakTime
|
08:00 (hours:mins)
|
00:00, 00:15, 00:30 .. 48:00
|
TXPP-MR-2_5G.config.client.AlsMode
|
Disabled
|
Disabled, Auto Restart, Manual Restart, Manual Restart for Test
|
TXPP-MR-2_5G.config.client.AlsRecoveryPulseDuration
|
40.0 (seconds)
|
•2.0, 2.1, 2.2 .. 100.0 when AlsMode is Disabled, Auto Restart, Manual Restart
•80.0, 80.1, 80.2 .. 100.0 when AlsMode is Manual Restart for Test
|
TXPP-MR-2_5G.config.client.AlsRecoveryPulseInterval
|
100 (seconds)
|
60-300
|
TXPP-MR-2_5G.config.client.ppmPortAssignment
|
UNASSIGNED
|
UNASSIGNED, STM1_PORT, STM4_PORT, STM16_PORT, ONE_GE_PORT, ESCON_PORT, DV6000_PORT, SDI_D1_VIDEO_PORT, HDTV_PORT, PASS_THRU_PORT, ETR_CLO_PORT, ISC compat, FC1G_PORT, FC2G_PORT, FICON1G_PORT, FICON2G_PORT, ISC peer
|
TXPP-MR-2_5G.config.client.ppmSlotAssignment
|
UNASSIGNED
|
UNASSIGNED, PPM (1 Port)
|
TXPP-MR-2_5G.config.client.SDBER
|
1E-7
|
1E-5, 1E-6, 1E-7, 1E-8, 1E-9
|
TXPP-MR-2_5G.config.client.SFBER
|
1E-4
|
1E-3, 1E-4, 1E-5
|
TXPP-MR-2_5G.config.client.TerminationMode
|
Transparent
|
•Transparent, Regeneration Section, Multiplex Section when ppmPortAssignment is UNASSIGNED, STM1_PORT, STM4_PORT, STM16_PORT
•Transparent when ppmPortAssignment is STM1_PORT, STM4_PORT, STM16_PORT, ONE_GE_PORT, ESCON_PORT, DV6000_PORT, SDI_D1_VIDEO_PORT, HDTV_PORT, PASS_THRU_PORT, ETR_CLO_PORT, ISC compat, FC1G_PORT, FC2G_PORT, FICON1G_PORT, FICON2G_PORT, ISC peer
|
TXPP-MR-2_5G.config.trunk.AINSSoakTime
|
08:00 (hours:mins)
|
00:00, 00:15, 00:30 .. 48:00
|
TXPP-MR-2_5G.config.trunk.AlsMode
|
Disabled
|
Disabled, Auto Restart, Manual Restart, Manual Restart for Test
|
TXPP-MR-2_5G.config.trunk.AlsRecoveryPulseDuration
|
40.0 (seconds)
|
•2.0, 2.1, 2.2 .. 100.0 when AlsMode is Disabled, Auto Restart, Manual Restart
•80.0, 80.1, 80.2 .. 100.0 when AlsMode is Manual Restart for Test
|
TXPP-MR-2_5G.config.trunk.AlsRecoveryPulseInterval
|
100 (seconds)
|
60-300
|
TXPP-MR-2_5G.config.trunk.SDBER
|
1E-7
|
1E-5, 1E-6, 1E-7, 1E-8, 1E-9
|
TXPP-MR-2_5G.config.trunk.SFBER
|
1E-4
|
1E-3, 1E-4, 1E-5
|
TXPP-MR-2_5G.opticalthresholds.client.alarm.HighLaserBias
|
90.0 (%)
|
0.0, 0.1, 0.2 .. 100.0
|
TXPP-MR-2_5G.opticalthresholds.client.alarm.HighRxPower
|
3.0 (dBm)
|
LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0
|
TXPP-MR-2_5G.opticalthresholds.client.alarm.HighTxPower
|
3.0 (dBm)
|
LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0
|
TXPP-MR-2_5G.opticalthresholds.client.alarm.LowRxPower
|
-21.0 (dBm)
|
-40.0, -39.9, -39.8 .. HighRxPower
|
TXPP-MR-2_5G.opticalthresholds.client.alarm.LowTxPower
|
-15.0 (dBm)
|
-40.0, -39.9, -39.8 .. HighTxPower
|
TXPP-MR-2_5G.opticalthresholds.client.warning.15min.HighLaserBias
|
81.0 (%)
|
0.0, 0.1, 0.2 .. 100.0
|
TXPP-MR-2_5G.opticalthresholds.client.warning.15min.HighRxPower
|
2.0 (dBm)
|
LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0
|
TXPP-MR-2_5G.opticalthresholds.client.warning.15min.HighTxPower
|
2.0 (dBm)
|
LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0
|
TXPP-MR-2_5G.opticalthresholds.client.warning.15min.LowRxPower
|
-20.0 (dBm)
|
-40.0, -39.9, -39.8 .. HighRxPower
|
TXPP-MR-2_5G.opticalthresholds.client.warning.15min.LowTxPower
|
-7.0 (dBm)
|
-40.0, -39.9, -39.8 .. HighTxPower
|
TXPP-MR-2_5G.opticalthresholds.client.warning.1day.HighLaserBias
|
85.5 (%)
|
0.0, 0.1, 0.2 .. 100.0
|
TXPP-MR-2_5G.opticalthresholds.client.warning.1day.HighRxPower
|
2.5 (dBm)
|
LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0
|
TXPP-MR-2_5G.opticalthresholds.client.warning.1day.HighTxPower
|
2.5 (dBm)
|
LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0
|
TXPP-MR-2_5G.opticalthresholds.client.warning.1day.LowRxPower
|
-20.5 (dBm)
|
-40.0, -39.9, -39.8 .. HighRxPower
|
TXPP-MR-2_5G.opticalthresholds.client.warning.1day.LowTxPower
|
-7.5 (dBm)
|
-40.0, -39.9, -39.8 .. HighTxPower
|
TXPP-MR-2_5G.opticalthresholds.trunk.alarm.HighLaserBias
|
98.0 (%)
|
0.0, 0.1, 0.2 .. 100.0
|
TXPP-MR-2_5G.opticalthresholds.trunk.alarm.HighRxPower
|
-8.0 (dBrn)
|
LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0
|
TXPP-MR-2_5G.opticalthresholds.trunk.alarm.LowRxPower
|
-25.0 (dBrn)
|
-40.0, -39.9, -39.8 .. HighRxPower
|
TXPP-MR-2_5G.opticalthresholds.trunk.warning.15min.HighLaserBias
|
95.0 (%)
|
0.0, 0.1, 0.2 .. 100.0
|
TXPP-MR-2_5G.opticalthresholds.trunk.warning.15min.HighRxPower
|
-7.5 (dBrn)
|
LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0
|
TXPP-MR-2_5G.opticalthresholds.trunk.warning.15min.LowRxPower
|
-24.5 (dBrn)
|
-40.0, -39.9, -39.8 .. HighRxPower
|
TXPP-MR-2_5G.opticalthresholds.trunk.warning.1day.HighLaserBias
|
96.0 (%)
|
0.0, 0.1, 0.2 .. 100.0
|
TXPP-MR-2_5G.opticalthresholds.trunk.warning.1day.HighRxPower
|
-7.3 (dBrn)
|
LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0
|
TXPP-MR-2_5G.opticalthresholds.trunk.warning.1day.LowRxPower
|
-24.7 (dBrn)
|
-40.0, -39.9, -39.8 .. HighRxPower
|
TXPP-MR-2_5G.otn.fecthresholds.1gethernet.15min.BitErrorsCorrected
|
112500 (count)
|
0-9033621811200
|
TXPP-MR-2_5G.otn.fecthresholds.1gethernet.15min.UncorrectableWords
|
1 (count)
|
0-4724697600
|
TXPP-MR-2_5G.otn.fecthresholds.1gethernet.1day.BitErrorsCorrected
|
10800000 (count)
|
0-867227693875200
|
TXPP-MR-2_5G.otn.fecthresholds.1gethernet.1day.UncorrectableWords
|
96 (count)
|
0-453570969600
|
TXPP-MR-2_5G.otn.fecthresholds.1gfiberchannel.15min.BitErrorsCorrected
|
90000 (count)
|
0-9033621811200
|
TXPP-MR-2_5G.otn.fecthresholds.1gfiberchannel.15min.UncorrectableWords
|
1 (count)
|
0-4724697600
|
TXPP-MR-2_5G.otn.fecthresholds.1gfiberchannel.1day.BitErrorsCorrected
|
8640000 (count)
|
0-867227693875200
|
TXPP-MR-2_5G.otn.fecthresholds.1gfiberchannel.1day.UncorrectableWords
|
96 (count)
|
0-453570969600
|
TXPP-MR-2_5G.otn.fecthresholds.1gficon.15min.BitErrorsCorrected
|
90000 (count)
|
0-9033621811200
|
TXPP-MR-2_5G.otn.fecthresholds.1gficon.15min.UncorrectableWords
|
1 (count)
|
0-4724697600
|
TXPP-MR-2_5G.otn.fecthresholds.1gficon.1day.BitErrorsCorrected
|
8640000 (count)
|
0-867227693875200
|
TXPP-MR-2_5G.otn.fecthresholds.1gficon.1day.UncorrectableWords
|
96 (count)
|
0-453570969600
|
TXPP-MR-2_5G.otn.fecthresholds.2gfiberchannel.15min.BitErrorsCorrected
|
180900 (count)
|
0-9033621811200
|
TXPP-MR-2_5G.otn.fecthresholds.2gfiberchannel.15min.UncorrectableWords
|
1 (count)
|
0-4724697600
|
TXPP-MR-2_5G.otn.fecthresholds.2gfiberchannel.1day.BitErrorsCorrected
|
17366400 (count)
|
0-867227693875200
|
TXPP-MR-2_5G.otn.fecthresholds.2gfiberchannel.1day.UncorrectableWords
|
96 (count)
|
0-453570969600
|
TXPP-MR-2_5G.otn.fecthresholds.2gficon.15min.BitErrorsCorrected
|
180900 (count)
|
0-9033621811200
|
TXPP-MR-2_5G.otn.fecthresholds.2gficon.15min.UncorrectableWords
|
1 (count)
|
0-4724697600
|
TXPP-MR-2_5G.otn.fecthresholds.2gficon.1day.BitErrorsCorrected
|
17366400 (count)
|
0-867227693875200
|
TXPP-MR-2_5G.otn.fecthresholds.2gficon.1day.UncorrectableWords
|
96 (count)
|
0-453570969600
|
TXPP-MR-2_5G.otn.fecthresholds.stm1.15min.BitErrorsCorrected
|
15012 (count)
|
0-9033621811200
|
TXPP-MR-2_5G.otn.fecthresholds.stm1.15min.UncorrectableWords
|
1 (count)
|
0-4724697600
|
TXPP-MR-2_5G.otn.fecthresholds.stm1.1day.BitErrorsCorrected
|
1441152 (count)
|
0-867227693875200
|
TXPP-MR-2_5G.otn.fecthresholds.stm1.1day.UncorrectableWords
|
96 (count)
|
0-453570969600
|
TXPP-MR-2_5G.otn.fecthresholds.stm16.15min.BitErrorsCorrected
|
225837 (count)
|
0-9033621811200
|
TXPP-MR-2_5G.otn.fecthresholds.stm16.15min.UncorrectableWords
|
1 (count)
|
0-4724697600
|
TXPP-MR-2_5G.otn.fecthresholds.stm16.1day.BitErrorsCorrected
|
21680352 (count)
|
0-867227693875200
|
TXPP-MR-2_5G.otn.fecthresholds.stm16.1day.UncorrectableWords
|
96 (count)
|
0-453570969600
|
TXPP-MR-2_5G.otn.fecthresholds.stm4.15min.BitErrorsCorrected
|
56457 (count)
|
0-9033621811200
|
TXPP-MR-2_5G.otn.fecthresholds.stm4.15min.UncorrectableWords
|
1 (count)
|
0-4724697600
|
TXPP-MR-2_5G.otn.fecthresholds.stm4.1day.BitErrorsCorrected
|
5419872 (count)
|
0-867227693875200
|
TXPP-MR-2_5G.otn.fecthresholds.stm4.1day.UncorrectableWords
|
96 (count)
|
0-453570969600
|
TXPP-MR-2_5G.otn.g709thresholds.pm.farend.15min.BBE
|
21260 (count)
|
0-8850600
|
TXPP-MR-2_5G.otn.g709thresholds.pm.farend.15min.ES
|
87 (seconds)
|
0-900
|
TXPP-MR-2_5G.otn.g709thresholds.pm.farend.15min.FC
|
10 (count)
|
0-72
|
TXPP-MR-2_5G.otn.g709thresholds.pm.farend.15min.SES
|
1 (seconds)
|
0-900
|
TXPP-MR-2_5G.otn.g709thresholds.pm.farend.15min.UAS
|
3 (seconds)
|
0-900
|
TXPP-MR-2_5G.otn.g709thresholds.pm.farend.1day.BBE
|
212600 (count)
|
0-849657600
|
TXPP-MR-2_5G.otn.g709thresholds.pm.farend.1day.ES
|
864 (seconds)
|
0-86400
|
TXPP-MR-2_5G.otn.g709thresholds.pm.farend.1day.FC
|
40 (count)
|
0-6912
|
TXPP-MR-2_5G.otn.g709thresholds.pm.farend.1day.SES
|
4 (seconds)
|
0-86400
|
TXPP-MR-2_5G.otn.g709thresholds.pm.farend.1day.UAS
|
10 (seconds)
|
0-86400
|
TXPP-MR-2_5G.otn.g709thresholds.pm.nearend.15min.BBE
|
21260 (count)
|
0-8850600
|
TXPP-MR-2_5G.otn.g709thresholds.pm.nearend.15min.ES
|
87 (seconds)
|
0-900
|
TXPP-MR-2_5G.otn.g709thresholds.pm.nearend.15min.FC
|
10 (count)
|
0-72
|
TXPP-MR-2_5G.otn.g709thresholds.pm.nearend.15min.SES
|
1 (seconds)
|
0-900
|
TXPP-MR-2_5G.otn.g709thresholds.pm.nearend.15min.UAS
|
3 (seconds)
|
0-900
|
TXPP-MR-2_5G.otn.g709thresholds.pm.nearend.1day.BBE
|
212600 (count)
|
0-849657600
|
TXPP-MR-2_5G.otn.g709thresholds.pm.nearend.1day.ES
|
864 (seconds)
|
0-86400
|
TXPP-MR-2_5G.otn.g709thresholds.pm.nearend.1day.FC
|
40 (count)
|
0-6912
|
TXPP-MR-2_5G.otn.g709thresholds.pm.nearend.1day.SES
|
4 (seconds)
|
0-86400
|
TXPP-MR-2_5G.otn.g709thresholds.pm.nearend.1day.UAS
|
10 (seconds)
|
0-86400
|
TXPP-MR-2_5G.otn.g709thresholds.sm.farend.15min.BBE
|
10000 (count)
|
0-8850600
|
TXPP-MR-2_5G.otn.g709thresholds.sm.farend.15min.ES
|
500 (seconds)
|
0-900
|
TXPP-MR-2_5G.otn.g709thresholds.sm.farend.15min.FC
|
10 (count)
|
0-72
|
TXPP-MR-2_5G.otn.g709thresholds.sm.farend.15min.SES
|
500 (seconds)
|
0-900
|
TXPP-MR-2_5G.otn.g709thresholds.sm.farend.15min.UAS
|
500 (seconds)
|
0-900
|
TXPP-MR-2_5G.otn.g709thresholds.sm.farend.1day.BBE
|
100000 (count)
|
0-849657600
|
TXPP-MR-2_5G.otn.g709thresholds.sm.farend.1day.ES
|
5000 (seconds)
|
0-86400
|
TXPP-MR-2_5G.otn.g709thresholds.sm.farend.1day.FC
|
40 (count)
|
0-6912
|
TXPP-MR-2_5G.otn.g709thresholds.sm.farend.1day.SES
|
5000 (seconds)
|
0-86400
|
TXPP-MR-2_5G.otn.g709thresholds.sm.farend.1day.UAS
|
5000 (seconds)
|
0-86400
|
TXPP-MR-2_5G.otn.g709thresholds.sm.nearend.15min.BBE
|
10000 (count)
|
0-8850600
|
TXPP-MR-2_5G.otn.g709thresholds.sm.nearend.15min.ES
|
500 (seconds)
|
0-900
|
TXPP-MR-2_5G.otn.g709thresholds.sm.nearend.15min.FC
|
10 (count)
|
0-72
|
TXPP-MR-2_5G.otn.g709thresholds.sm.nearend.15min.SES
|
500 (seconds)
|
0-900
|
TXPP-MR-2_5G.otn.g709thresholds.sm.nearend.15min.UAS
|
500 (seconds)
|
0-900
|
TXPP-MR-2_5G.otn.g709thresholds.sm.nearend.1day.BBE
|
100000 (count)
|
0-849657600
|
TXPP-MR-2_5G.otn.g709thresholds.sm.nearend.1day.ES
|
5000 (seconds)
|
0-86400
|
TXPP-MR-2_5G.otn.g709thresholds.sm.nearend.1day.FC
|
40 (count)
|
0-6912
|
TXPP-MR-2_5G.otn.g709thresholds.sm.nearend.1day.SES
|
5000 (seconds)
|
0-86400
|
TXPP-MR-2_5G.otn.g709thresholds.sm.nearend.1day.UAS
|
5000 (seconds)
|
0-86400
|
TXPP-MR-2_5G.otn.otnLines.FEC
|
Enable
|
•Disable, Enable when G709OTN is Enable
•Disable when G709OTN is Disable
|
TXPP-MR-2_5G.otn.otnLines.G709OTN
|
Enable
|
Disable, Enable
|
TXPP-MR-2_5G.otn.otnLines.SDBER
|
1E-7
|
1E-5, 1E-6, 1E-7, 1E-8, 1E-9
|
TXPP-MR-2_5G.pmthresholds.stm1.ms.farend.15min.BBE
|
1312 (count)
|
0-137700
|
TXPP-MR-2_5G.pmthresholds.stm1.ms.farend.15min.EB
|
1312 (count)
|
0-137700
|
TXPP-MR-2_5G.pmthresholds.stm1.ms.farend.15min.ES
|
87 (seconds)
|
0-900
|
TXPP-MR-2_5G.pmthresholds.stm1.ms.farend.15min.SES
|
1 (seconds)
|
0-900
|
TXPP-MR-2_5G.pmthresholds.stm1.ms.farend.15min.UAS
|
3 (seconds)
|
0-900
|
TXPP-MR-2_5G.pmthresholds.stm1.ms.farend.1day.BBE
|
13120 (count)
|
0-13219200
|
TXPP-MR-2_5G.pmthresholds.stm1.ms.farend.1day.EB
|
13120 (count)
|
0-13219200
|
TXPP-MR-2_5G.pmthresholds.stm1.ms.farend.1day.ES
|
864 (seconds)
|
0-86400
|
TXPP-MR-2_5G.pmthresholds.stm1.ms.farend.1day.SES
|
4 (seconds)
|
0-86400
|
TXPP-MR-2_5G.pmthresholds.stm1.ms.farend.1day.UAS
|
10 (seconds)
|
0-86400
|
TXPP-MR-2_5G.pmthresholds.stm1.ms.nearend.15min.BBE
|
1312 (count)
|
0-137700
|
TXPP-MR-2_5G.pmthresholds.stm1.ms.nearend.15min.EB
|
1312 (count)
|
0-137700
|
TXPP-MR-2_5G.pmthresholds.stm1.ms.nearend.15min.ES
|
87 (seconds)
|
0-900
|
TXPP-MR-2_5G.pmthresholds.stm1.ms.nearend.15min.SES
|
1 (seconds)
|
0-900
|
TXPP-MR-2_5G.pmthresholds.stm1.ms.nearend.15min.UAS
|
3 (seconds)
|
0-900
|
TXPP-MR-2_5G.pmthresholds.stm1.ms.nearend.1day.BBE
|
13120 (count)
|
0-13219200
|
TXPP-MR-2_5G.pmthresholds.stm1.ms.nearend.1day.EB
|
13120 (count)
|
0-13219200
|
TXPP-MR-2_5G.pmthresholds.stm1.ms.nearend.1day.ES
|
864 (seconds)
|
0-86400
|
TXPP-MR-2_5G.pmthresholds.stm1.ms.nearend.1day.SES
|
4 (seconds)
|
0-86400
|
TXPP-MR-2_5G.pmthresholds.stm1.ms.nearend.1day.UAS
|
10 (seconds)
|
0-86400
|
TXPP-MR-2_5G.pmthresholds.stm1.rs.nearend.15min.BBE
|
10000 (count)
|
0-138600
|
TXPP-MR-2_5G.pmthresholds.stm1.rs.nearend.15min.EB
|
10000 (count)
|
0-138600
|
TXPP-MR-2_5G.pmthresholds.stm1.rs.nearend.15min.ES
|
500 (seconds)
|
0-900
|
TXPP-MR-2_5G.pmthresholds.stm1.rs.nearend.15min.SES
|
500 (seconds)
|
0-900
|
TXPP-MR-2_5G.pmthresholds.stm1.rs.nearend.15min.UAS
|
3 (seconds)
|
0-900
|
TXPP-MR-2_5G.pmthresholds.stm1.rs.nearend.1day.BBE
|
10000 (count)
|
0-13305600
|
TXPP-MR-2_5G.pmthresholds.stm1.rs.nearend.1day.EB
|
100000 (count)
|
0-13305600
|
TXPP-MR-2_5G.pmthresholds.stm1.rs.nearend.1day.ES
|
5000 (seconds)
|
0-86400
|
TXPP-MR-2_5G.pmthresholds.stm1.rs.nearend.1day.SES
|
5000 (seconds)
|
0-86400
|
TXPP-MR-2_5G.pmthresholds.stm1.rs.nearend.1day.UAS
|
10 (seconds)
|
0-86400
|
TXPP-MR-2_5G.pmthresholds.stm16.ms.farend.15min.BBE
|
21260 (count)
|
0-2212200
|
TXPP-MR-2_5G.pmthresholds.stm16.ms.farend.15min.EB
|
21260 (count)
|
0-2212200
|
TXPP-MR-2_5G.pmthresholds.stm16.ms.farend.15min.ES
|
87 (seconds)
|
0-900
|
TXPP-MR-2_5G.pmthresholds.stm16.ms.farend.15min.SES
|
1 (seconds)
|
0-900
|
TXPP-MR-2_5G.pmthresholds.stm16.ms.farend.15min.UAS
|
3 (seconds)
|
0-900
|
TXPP-MR-2_5G.pmthresholds.stm16.ms.farend.1day.BBE
|
212600 (count)
|
0-212371200
|
TXPP-MR-2_5G.pmthresholds.stm16.ms.farend.1day.EB
|
212600 (seconds)
|
0-212371200
|
TXPP-MR-2_5G.pmthresholds.stm16.ms.farend.1day.ES
|
864 (seconds)
|
0-900
|
TXPP-MR-2_5G.pmthresholds.stm16.ms.farend.1day.SES
|
4 (seconds)
|
0-86400
|
TXPP-MR-2_5G.pmthresholds.stm16.ms.farend.1day.UAS
|
10 (seconds)
|
0-86400
|
TXPP-MR-2_5G.pmthresholds.stm16.ms.nearend.15min.BBE
|
21260 (count)
|
0-2212200
|
TXPP-MR-2_5G.pmthresholds.stm16.ms.nearend.15min.EB
|
21260 (count)
|
0-2212200
|
TXPP-MR-2_5G.pmthresholds.stm16.ms.nearend.15min.ES
|
87 (seconds)
|
0-900
|
TXPP-MR-2_5G.pmthresholds.stm16.ms.nearend.15min.SES
|
1 (seconds)
|
0-900
|
TXPP-MR-2_5G.pmthresholds.stm16.ms.nearend.15min.UAS
|
3 (seconds)
|
0-900
|
TXPP-MR-2_5G.pmthresholds.stm16.ms.nearend.1day.BBE
|
212600 (count)
|
0-212371200
|
TXPP-MR-2_5G.pmthresholds.stm16.ms.nearend.1day.EB
|
212600 (count)
|
0-212371200
|
TXPP-MR-2_5G.pmthresholds.stm16.ms.nearend.1day.ES
|
864 (seconds)
|
0-86400
|
TXPP-MR-2_5G.pmthresholds.stm16.ms.nearend.1day.SES
|
4 (seconds)
|
0-86400
|
TXPP-MR-2_5G.pmthresholds.stm16.ms.nearend.1day.UAS
|
10 (seconds)
|
0-86400
|
TXPP-MR-2_5G.pmthresholds.stm16.rs.nearend.15min.BBE
|
10000 (count)
|
0-2151900
|
TXPP-MR-2_5G.pmthresholds.stm16.rs.nearend.15min.EB
|
10000 (count)
|
0-2151900
|
TXPP-MR-2_5G.pmthresholds.stm16.rs.nearend.15min.ES
|
500 (seconds)
|
0-900
|
TXPP-MR-2_5G.pmthresholds.stm16.rs.nearend.15min.SES
|
500 (seconds)
|
0-900
|
TXPP-MR-2_5G.pmthresholds.stm16.rs.nearend.15min.UAS
|
3 (seconds)
|
0-900
|
TXPP-MR-2_5G.pmthresholds.stm16.rs.nearend.1day.BBE
|
10000 (count)
|
0-206582400
|
TXPP-MR-2_5G.pmthresholds.stm16.rs.nearend.1day.EB
|
100000 (count)
|
0-206582400
|
TXPP-MR-2_5G.pmthresholds.stm16.rs.nearend.1day.ES
|
5000 (seconds)
|
0-86400
|
TXPP-MR-2_5G.pmthresholds.stm16.rs.nearend.1day.SES
|
5000 (seconds)
|
0-86400
|
TXPP-MR-2_5G.pmthresholds.stm16.rs.nearend.1day.UAS
|
10 (seconds)
|
0-86400
|
TXPP-MR-2_5G.pmthresholds.stm4.ms.farend.15min.BBE
|
5315 (count)
|
0-552600
|
TXPP-MR-2_5G.pmthresholds.stm4.ms.farend.15min.EB
|
5315 (count)
|
0-552600
|
TXPP-MR-2_5G.pmthresholds.stm4.ms.farend.15min.ES
|
87 (seconds)
|
0-900
|
TXPP-MR-2_5G.pmthresholds.stm4.ms.farend.15min.SES
|
1 (seconds)
|
0-900
|
TXPP-MR-2_5G.pmthresholds.stm4.ms.farend.15min.UAS
|
3 (seconds)
|
0-900
|
TXPP-MR-2_5G.pmthresholds.stm4.ms.farend.1day.BBE
|
53150 (count)
|
0-53049600
|
TXPP-MR-2_5G.pmthresholds.stm4.ms.farend.1day.EB
|
53150 (count)
|
0-53049600
|
TXPP-MR-2_5G.pmthresholds.stm4.ms.farend.1day.ES
|
864 (seconds)
|
0-86400
|
TXPP-MR-2_5G.pmthresholds.stm4.ms.farend.1day.SES
|
4 (seconds)
|
0-86400
|
TXPP-MR-2_5G.pmthresholds.stm4.ms.farend.1day.UAS
|
10 (seconds)
|
0-86400
|
TXPP-MR-2_5G.pmthresholds.stm4.ms.nearend.15min.BBE
|
5315 (count)
|
0-552600
|
TXPP-MR-2_5G.pmthresholds.stm4.ms.nearend.15min.EB
|
5315 (count)
|
0-552600
|
TXPP-MR-2_5G.pmthresholds.stm4.ms.nearend.15min.ES
|
87 (seconds)
|
0-900
|
TXPP-MR-2_5G.pmthresholds.stm4.ms.nearend.15min.SES
|
1 (seconds)
|
0-900
|
TXPP-MR-2_5G.pmthresholds.stm4.ms.nearend.15min.UAS
|
3 (seconds)
|
0-900
|
TXPP-MR-2_5G.pmthresholds.stm4.ms.nearend.1day.BBE
|
53150 (count)
|
0-53049600
|
TXPP-MR-2_5G.pmthresholds.stm4.ms.nearend.1day.EB
|
53150 (count)
|
0-53049600
|
TXPP-MR-2_5G.pmthresholds.stm4.ms.nearend.1day.ES
|
864 (seconds)
|
0-86400
|
TXPP-MR-2_5G.pmthresholds.stm4.ms.nearend.1day.SES
|
4 (seconds)
|
0-86400
|
TXPP-MR-2_5G.pmthresholds.stm4.ms.nearend.1day.UAS
|
10 (seconds)
|
0-86400
|
TXPP-MR-2_5G.pmthresholds.stm4.rs.nearend.15min.BBE
|
10000 (count)
|
0-553500
|
TXPP-MR-2_5G.pmthresholds.stm4.rs.nearend.15min.EB
|
10000 (count)
|
0-553500
|
TXPP-MR-2_5G.pmthresholds.stm4.rs.nearend.15min.ES
|
500 (seconds)
|
0-900
|
TXPP-MR-2_5G.pmthresholds.stm4.rs.nearend.15min.SES
|
500 (seconds)
|
0-900
|
TXPP-MR-2_5G.pmthresholds.stm4.rs.nearend.15min.UAS
|
3 (seconds)
|
0-900
|
TXPP-MR-2_5G.pmthresholds.stm4.rs.nearend.1day.BBE
|
10000 (count)
|
0-53136000
|
TXPP-MR-2_5G.pmthresholds.stm4.rs.nearend.1day.EB
|
100000 (count)
|
0-53136000
|
TXPP-MR-2_5G.pmthresholds.stm4.rs.nearend.1day.ES
|
5000 (seconds)
|
0-86400
|
TXPP-MR-2_5G.pmthresholds.stm4.rs.nearend.1day.SES
|
5000 (seconds)
|
0-86400
|
TXPP-MR-2_5G.pmthresholds.stm4.rs.nearend.1day.UAS
|
10 (seconds)
|
0-86400
|
D.3.1.9 OSCM Card Default Settings
Table D-21 lists the OSCM card default settings.
Table D-21 OSCM Card Default Settings (ETSI)
Default Name
|
Default Value
|
Default Domain
|
OSCM.pmthresholds.ms.farend.15min.BBE
|
1312 (count)
|
0-137700
|
OSCM.pmthresholds.ms.farend.15min.EB
|
1312 (count)
|
0-137700
|
OSCM.pmthresholds.ms.farend.15min.ES
|
87 (seconds)
|
0-900
|
OSCM.pmthresholds.ms.farend.15min.SES
|
1 (seconds)
|
0-900
|
OSCM.pmthresholds.ms.farend.15min.UAS
|
3 (seconds)
|
0-900
|
OSCM.pmthresholds.ms.farend.1day.BBE
|
13120 (count)
|
0-13219200
|
OSCM.pmthresholds.ms.farend.1day.EB
|
13120 (count)
|
0-13219200
|
OSCM.pmthresholds.ms.farend.1day.ES
|
864 (seconds)
|
0-86400
|
OSCM.pmthresholds.ms.farend.1day.SES
|
4 (seconds)
|
0-86400
|
OSCM.pmthresholds.ms.farend.1day.UAS
|
10 (seconds)
|
0-86400
|
OSCM.pmthresholds.ms.nearend.15min.BBE
|
1312 (count)
|
0-137700
|
OSCM.pmthresholds.ms.nearend.15min.EB
|
1312 (count)
|
0-137700
|
OSCM.pmthresholds.ms.nearend.15min.ES
|
87 (seconds)
|
0-900
|
OSCM.pmthresholds.ms.nearend.15min.SES
|
1 (seconds)
|
0-900
|
OSCM.pmthresholds.ms.nearend.15min.UAS
|
3 (seconds)
|
0-900
|
OSCM.pmthresholds.ms.nearend.1day.BBE
|
13120 (count)
|
0-13219200
|
OSCM.pmthresholds.ms.nearend.1day.EB
|
13120 (count)
|
0-13219200
|
OSCM.pmthresholds.ms.nearend.1day.ES
|
864 (seconds)
|
0-86400
|
OSCM.pmthresholds.ms.nearend.1day.SES
|
4 (seconds)
|
0-86400
|
OSCM.pmthresholds.ms.nearend.1day.UAS
|
10 (seconds)
|
0-86400
|
OSCM.pmthresholds.rs.nearend.15min.BBE
|
10000 (count)
|
0-138600
|
OSCM.pmthresholds.rs.nearend.15min.EB
|
10000 (count)
|
0-138600
|
OSCM.pmthresholds.rs.nearend.15min.ES
|
500 (seconds)
|
0-900
|
OSCM.pmthresholds.rs.nearend.15min.SEFS
|
500 (seconds)
|
0-900
|
OSCM.pmthresholds.rs.nearend.15min.SES
|
500 (seconds)
|
0-900
|
OSCM.pmthresholds.rs.nearend.1day.BBE
|
100000 (count)
|
0-13305600
|
OSCM.pmthresholds.rs.nearend.1day.EB
|
100000 (count)
|
0-13305600
|
OSCM.pmthresholds.rs.nearend.1day.ES
|
5000 (seconds)
|
0-86400
|
OSCM.pmthresholds.rs.nearend.1day.SEFS
|
5000 (seconds)
|
0-86400
|
OSCM.pmthresholds.rs.nearend.1day.SES
|
5000 (seconds)
|
0-86400
|
D.3.1.10 OSC-CSM Card Default Settings
Table D-22 lists the OSC-CSM card default settings.
Table D-22 OSC-CSM Card Default Settings (ETSI)
Default Name
|
Default Value
|
Default Domain
|
OSC_CSM.pmthresholds.ms.farend.15min.BBE
|
1312 (count)
|
0-137700
|
OSC_CSM.pmthresholds.ms.farend.15min.EB
|
1312 (count)
|
0-137700
|
OSC_CSM.pmthresholds.ms.farend.15min.ES
|
87 (seconds)
|
0-900
|
OSC_CSM.pmthresholds.ms.farend.15min.SES
|
1 (seconds)
|
0-900
|
OSC_CSM.pmthresholds.ms.farend.15min.UAS
|
3 (seconds)
|
0-900
|
OSC_CSM.pmthresholds.ms.farend.1day.BBE
|
13120 (count)
|
0-13219200
|
OSC_CSM.pmthresholds.ms.farend.1day.EB
|
13120 (count)
|
0-13219200
|
OSC_CSM.pmthresholds.ms.farend.1day.ES
|
864 (seconds)
|
0-86400
|
OSC_CSM.pmthresholds.ms.farend.1day.SES
|
4 (seconds)
|
0-86400
|
OSC_CSM.pmthresholds.ms.farend.1day.UAS
|
10 (seconds)
|
0-86400
|
OSC_CSM.pmthresholds.ms.nearend.15min.BBE
|
1312 (count)
|
0-137700
|
OSC_CSM.pmthresholds.ms.nearend.15min.EB
|
1312 (count)
|
0-137700
|
OSC_CSM.pmthresholds.ms.nearend.15min.ES
|
87 (seconds)
|
0-900
|
OSC_CSM.pmthresholds.ms.nearend.15min.SES
|
1 (seconds)
|
0-900
|
OSC_CSM.pmthresholds.ms.nearend.15min.UAS
|
3 (seconds)
|
0-900
|
OSC_CSM.pmthresholds.ms.nearend.1day.BBE
|
13120 (count)
|
0-13219200
|
OSC_CSM.pmthresholds.ms.nearend.1day.EB
|
13120 (count)
|
0-13219200
|
OSC_CSM.pmthresholds.ms.nearend.1day.ES
|
864 (seconds)
|
0-86400
|
OSC_CSM.pmthresholds.ms.nearend.1day.SES
|
4 (seconds)
|
0-86400
|
OSC_CSM.pmthresholds.ms.nearend.1day.UAS
|
10 (seconds)
|
0-86400
|
OSC_CSM.pmthresholds.rs.nearend.15min.BBE
|
10000 (count)
|
0-138600
|
OSC_CSM.pmthresholds.rs.nearend.15min.EB
|
10000 (count)
|
0-138600
|
OSC_CSM.pmthresholds.rs.nearend.15min.ES
|
500 (seconds)
|
0-900
|
OSC_CSM.pmthresholds.rs.nearend.15min.SEFS
|
500 (seconds)
|
0-900
|
OSC_CSM.pmthresholds.rs.nearend.15min.SES
|
500 (seconds)
|
0-900
|
OSC_CSM.pmthresholds.rs.nearend.1day.BBE
|
100000 (count)
|
0-13305600
|
OSC_CSM.pmthresholds.rs.nearend.1day.EB
|
100000 (count)
|
0-13305600
|
OSC_CSM.pmthresholds.rs.nearend.1day.ES
|
5000 (seconds)
|
0-86400
|
OSC_CSM.pmthresholds.rs.nearend.1day.SEFS
|
5000 (seconds)
|
0-86400
|
OSC_CSM.pmthresholds.rs.nearend.1day.SES
|
5000 (seconds)
|
0-86400
|
D.3.2 ETSI Node Default Settings
Table D-23 lists the Cisco ONS 15454 node-level default settings for the ETSI shelf assembly. Cisco provides the following user-configurable defaults for each Cisco ONS 15454 node:
•SNCP settings—Set the threshold level for signal degradation and failure for subnetwork connection protection (SNCP) circuits.
•Craft Access Only—Allows CTC connectivity to the node only through the craft access port.
•CTC IP Display Suppression—Prevents display of node IP addresses in CTC (applicable for all users except Superusers).
•Defaults Description—Names the current defaults file on the node.
•Enable Firewall—Enables or disables the use of a firewall for accessing the node.
•Enable Proxy—Enables or disables the use of a proxy server with the node.
•IIOP Listener Port—Sets the IIOP listener port number.
•LCD IP setting—Sets the node LCD screen to display the node IP address and use the buttons on the LCD panel, only display the IP address, or suppress display of the IP address.
•Login Warning Message—Warns users at the login screen about the possible legal or contractual ramifications of accessing equipment, systems, or networks without authorization.
•NTP SNTP Server—Sets the IP address of the NTP SNTP server to be used with the node.
•Time Zone—Sets the time zone where the node is located.
•Use DST—Enables or disables the use of Daylight Savings Time.
•Use NTP SNTP Server—Enables or disables the use of the specified NTP SNTP server with the node.
•Linear Multiplex Section Protection (LMSP) settings—Determine whether or not LMSP-protected circuits have bidirectional switching, are revertive, and what the reversion time is.
•MS-SPRing protection settings—Determine whether multiplex section-shared protection ring (MS-SPRing) protected circuits are revertive and what the reversion time is at both the ring and span levels.
•Y Cable Protection settings—Determine whether Y-cable protected circuits have bidirectional switching, are revertive, and what the reversion time is.
•Security Policy settings—Determine the allowable failed logins before lockout, idle user timeout for each user level, optional lockout duration or manual unlock enabled, password reuse and change frequency policies, number of characters difference between the old and new password, password aging by security level, enforced single concurrent session per user, and disable inactive user after a set inactivity period.
•BITS Timing settings—Determine the AIS threshold, coding, framing, State, State Out, and LBO settings for BITS1 and BITS2 timing.
•General Timing settings—Determine the mode (External, Line, or Mixed), quality of RES, revertive, reversion time, and SSM message set for node timing.
Note For more information about each individual node setting, see Chapter 10, "Manage the Node."
Table D-23 Node Default Settings (ETSI)
Default Name
|
Default Value
|
Default Domain
|
NODE.circuits.sncp.HO_SDBER
|
1E-6
|
1E-5, 1E-6, 1E-7, 1E-8, 1E-9
|
NODE.circuits.sncp.HO_SFBER
|
1E-4
|
1E-3, 1E-4, 1E-5
|
NODE.circuits.sncp.LO_SDBER
|
1E-6
|
1E-5, 1E-6, 1E-7, 1E-8
|
NODE.circuits.sncp.LO_SFBER
|
1E-4
|
1E-3, 1E-4, 1E-5
|
NODE.circuits.sncp.ReversionTime
|
5.0 (minutes)
|
0.5, 1.0, 1.5 .. 12.0
|
NODE.circuits.sncp.Revertive
|
FALSE
|
TRUE, FALSE
|
NODE.circuits.State
|
unlocked, automaticInService
|
unlocked, locked, disabled, locked, maintenance, unlocked, automaticInService
|
NODE.general.DefaultsDescription
|
Factory Defaults
|
Free form field
|
NODE.general.NtpSntpServer
|
0.0.0.0
|
IP Address
|
NODE.general.TimeZone
|
(GMT-08:00) Pacific Time (US & Canada), Tijuana
|
(For applicable time zones, see Table D-24.)
|
NODE.general.UseDST
|
TRUE
|
TRUE, FALSE
|
NODE.network.general.AlarmMissingBackplaneLAN
|
FALSE
|
TRUE, FALSE
|
NODE.network.general.CtcIpDisplaySuppression
|
FALSE
|
TRUE, FALSE
|
NODE.network.general.GatewaySettings
|
None
|
LeaveAsIs, None, ENE, GNE, ProxyOnlyNode
|
NODE.network.general.LcdIpSetting
|
Allow Configuration
|
Allow Configuration, Display Only, Suppress Display
|
NODE.osi.greTunnel.ctc.OspfCost
|
110
|
110, 120, 130 .. 65530
|
NODE.osi.greTunnel.ctc.SubnetMask
|
24 (bits)
|
8, 9, 10 .. 32
|
NODE.osi.lapd.ctc.Mode
|
AITS
|
AITS, UITS
|
NODE.osi.lapd.ctc.MTU
|
512
|
512, 513, 514 .. 1500
|
NODE.osi.lapd.ctc.Role
|
Network
|
Network, User
|
NODE.osi.lapd.ctc.T200
|
200 (ms)
|
200, 300, 400 .. 20000
|
NODE.osi.lapd.ctc.T203
|
10000 (ms)
|
4000, 4100, 4200 .. 120000
|
NODE.osi.mainSetup.L1L2LSPBufferSize
|
512 (bytes)
|
512-1500
|
NODE.osi.mainSetup.L1LSPBufferSize
|
512 (bytes)
|
512-1500
|
NODE.osi.mainSetup.NodeRoutingMode
|
Intermediate System Level 1
|
End System, Intermediate System Level 1, Intermediate System Level 1/Level 2
|
NODE.osi.subnet.ctc.DISPriority
|
63
|
1, 2, 3 .. 127
|
NODE.osi.subnet.ctc.ESH
|
10 (sec)
|
10, 20, 30 .. 1000
|
NODE.osi.subnet.ctc.GCCISISCost
|
60
|
1, 2, 3 .. 63
|
NODE.osi.subnet.ctc.IIH
|
3 (sec)
|
1, 2, 3 .. 600
|
NODE.osi.subnet.ctc.ISH
|
10 (sec)
|
10, 20, 30 .. 1000
|
NODE.osi.subnet.ctc.LANISISCost
|
20
|
1, 2, 3 .. 63
|
NODE.osi.subnet.ctc.LDCCISISCost
|
40
|
1, 2, 3 .. 63
|
NODE.osi.subnet.ctc.OSCISISCost
|
60
|
1, 2, 3 .. 63
|
NODE.osi.subnet.ctc.SDCCISISCost
|
60
|
1, 2, 3 .. 63
|
NODE.osi.tarp.L1DataCache
|
TRUE
|
FALSE, TRUE
|
NODE.osi.tarp.L2DataCache
|
FALSE
|
FALSE, TRUE
|
NODE.osi.tarp.LANStormSuppression
|
TRUE
|
FALSE, TRUE
|
NODE.osi.tarp.LDB
|
TRUE
|
FALSE, TRUE
|
NODE.osi.tarp.LDBEntry
|
5 (min)
|
1-10
|
NODE.osi.tarp.LDBFlush
|
5 (sec)
|
0-1440
|
NODE.osi.tarp.PDUsL1Propagation
|
TRUE
|
FALSE, TRUE
|
NODE.osi.tarp.PDUsL2Propagation
|
TRUE
|
FALSE, TRUE
|
NODE.osi.tarp.PDUsOrigination
|
TRUE
|
FALSE, TRUE
|
NODE.osi.tarp.T1Timer
|
15 (sec)
|
0-3600
|
NODE.osi.tarp.T2Timer
|
25 (sec)
|
0-3600
|
NODE.osi.tarp.T3Timer
|
40 (sec)
|
0-3600
|
NODE.osi.tarp.T4Timer
|
20 (sec)
|
0-3600
|
NODE.osi.tarp.Type4PDUDelay
|
0 (sec)
|
0-255
|
NODE.powerMonitor.EHIBATVG_48V
|
-56.5 (Vdc)
|
-40.5, -41.0, -41.5 .. -57.0
|
NODE.powerMonitor.EHIBATVG_60V
|
-72.0 (Vdc)
|
-50.0, -50.5, -51.0 .. -72.0
|
NODE.powerMonitor.ELWBATVG_48V
|
-40.5 (Vdc)
|
-40.5, -41.0, -41.5 .. -56.5
|
NODE.powerMonitor.ELWBATVG_60V
|
-50.0 (Vdc)
|
-50.0, -50.5, -51.0 .. -72.0
|
NODE.protection.Cisco ONS 15454.BidirectionalSwitching
|
FALSE
|
TRUE, FALSE
|
NODE.protection.lmsp.ReversionTime
|
5.0 (minutes)
|
0.5, 1.0, 1.5 .. 12.0
|
NODE.protection.lmsp.Revertive
|
FALSE
|
TRUE, FALSE
|
NODE.protection.msspr.RingReversionTime
|
5.0 (minutes)
|
0.5, 1.0, 1.5 .. 12.0
|
NODE.protection.msspr.RingRevertive
|
TRUE
|
TRUE, FALSE
|
NODE.protection.msspr.SpanReversionTime
|
5.0 (minutes)
|
0.5, 1.0, 1.5 .. 12.0
|
NODE.protection.msspr.SpanRevertive
|
TRUE
|
TRUE, FALSE
|
NODE.protection.splitter.ReversionTime
|
5.0 (minutes)
|
0.5, 1.0, 1.5 .. 12.0
|
NODE.protection.splitter.Revertive
|
FALSE
|
TRUE, FALSE
|
NODE.protection.ycable.ReversionTime
|
5.0 (minutes)
|
0.5, 1.0, 1.5 .. 12.0
|
NODE.protection.ycable.Revertive
|
FALSE
|
TRUE, FALSE
|
NODE.security.dataComm.ctc.DefaultTCCEthernetIP
|
10.0.0.1
|
IP Address
|
NODE.security.dataComm.ctc.DefaultTCCEthernetIPNetmask
|
24 (bits)
|
8, 9, 10 .. 32
|
NODE.security.dataComm.CtcBackplaneIpDisplaySuppression
|
(NOT SUPPORTED)
|
•FALSE, TRUE when isSecureModeSupportedOnControlCard is TRUE
•(NOT SUPPORTED) when isSecureModeSupportedOnControlCard is FALSE
|
NODE.security.dataComm.isSecureModeSupportedOnControlCard
|
FALSE
|
FALSE, TRUE
|
NODE.security.dataComm.LcdBackplaneIpSetting
|
(NOT SUPPORTED)
|
•Allow Configuration, Display Only, Suppress Display when isSecureModeSupportedOnControlCard is TRUE
•(NOT SUPPORTED) when isSecureModeSupportedOnControlCard is FALSE
|
NODE.security.dataComm.SecureModeLocked
|
(NOT SUPPORTED)
|
•FALSE, TRUE when isSecureModeSupportedOnControlCard is TRUE
•(NOT SUPPORTED) when isSecureModeSupportedOnControlCard is FALSE
|
NODE.security.dataComm.SecureModeOn (May reboot node)
|
(NOT SUPPORTED)
|
•FALSE, TRUE when isSecureModeSupportedOnControlCard is TRUE
•(NOT SUPPORTED) when isSecureModeSupportedOnControlCard is FALSE
|
NODE.security.emsAccess.AccessState
|
NonSecure
|
NonSecure, Secure
|
NODE.security.emsAccess.IIOPListenerPort (May reboot node)
|
57790 (port #)
|
0-65535
|
NODE.security.idleUserTimeout.Maintenance
|
01:00 (hours:mins)
|
00:00, 00:01, 00:02 .. 16:39
|
NODE.security.idleUserTimeout.Provisioning
|
00:30 (hours:mins)
|
00:00, 00:01, 00:02 .. 16:39
|
NODE.security.idleUserTimeout.Retrieve
|
00:00 (hours:mins)
|
00:00, 00:01, 00:02 .. 16:39
|
NODE.security.idleUserTimeout.Superuser
|
00:15 (hours:mins)
|
00:00, 00:01, 00:02 .. 16:39
|
NODE.security.lanAccess.LANAccess (May disconnect CTC from node)
|
Front & Backplane
|
No LAN Access, Front Only, Backplane Only, Front & Backplane
|
NODE.security.lanAccess.RestoreTimeout
|
5 (minutes)
|
0-60
|
NODE.security.legalDisclaimer.LoginWarningMessage
|
<html><center><b>WARNING</b></center>This system is restricted to authorized users for business purposes. Unauthorized<p>access is a violation of the law. This service may be monitored for administrative<p>and security reasons. By proceeding, you consent to this monitoring.
|
Free form field
|
NODE.security.other.DisableInactiveUser
|
FALSE
|
FALSE, TRUE
|
NODE.security.other.InactiveDuration
|
45 (days)
|
•1, 2, 3 .. 99 when DisableInactiveUser is TRUE
•45 (and N/A) when DisableInactiveUser is FALSE
|
NODE.security.other.PMClearingPrivilege
|
Provisioning
|
Provisioning, Superuser
|
NODE.security.other.SingleSessionPerUser
|
FALSE
|
TRUE, FALSE
|
NODE.security.passwordAging.EnforcePasswordAging
|
FALSE
|
TRUE, FALSE
|
NODE.security.passwordAging.maintenance.AgingPeriod
|
45 (days)
|
20-90
|
NODE.security.passwordAging.maintenance.WarningPeriod
|
5 (days)
|
2-20
|
NODE.security.passwordAging.provisioning.AgingPeriod
|
45 (days)
|
20-90
|
NODE.security.passwordAging.provisioning.WarningPeriod
|
5 (days)
|
2-20
|
NODE.security.passwordAging.retrieve.AgingPeriod
|
45 (days)
|
20-90
|
NODE.security.passwordAging.retrieve.WarningPeriod
|
5 (days)
|
2-20
|
NODE.security.passwordAging.superuser.AgingPeriod
|
45 (days)
|
20-90
|
NODE.security.passwordAging.superuser.WarningPeriod
|
5 (days)
|
2-20
|
NODE.security.passwordChange.CannotChangeNewPassword
|
FALSE
|
TRUE, FALSE
|
NODE.security.passwordChange.CannotChangeNewPasswordForNDays
|
20 (days)
|
20-95
|
NODE.security.passwordChange.NewPasswordMustDifferFromOldByNCharacters
|
1 (characters)
|
1-20
|
NODE.security.passwordChange.PreventReusingLastNPasswords
|
1 (times)
|
1-10
|
NODE.security.passwordChange.RequirePasswordChangeOnFirstLoginToNewAccount
|
FALSE
|
TRUE, FALSE
|
NODE.security.radiusServer.ctc.AccountingPort
|
1813 (port)
|
0-32767
|
NODE.security.radiusServer.ctc.AuthenticationPort
|
1812 (port)
|
0-32767
|
NODE.security.radiusServer.EnableNodeAsFinalAuthenticatorWhenAuthenticationEnabled
|
TRUE
|
FALSE, TRUE
|
NODE.security.serialCraftAccess.EnableCraftPort
|
TRUE
|
TRUE, FALSE
|
NODE.security.shellAccess.AccessState
|
NonSecure
|
Disabled, NonSecure, Secure
|
NODE.security.shellAccess.EnableShellPassword
|
FALSE
|
TRUE, FALSE
|
NODE.security.shellAccess.TelnetPort
|
23
|
23-9999
|
NODE.security.snmpAccess.AccessState
|
NonSecure
|
Disabled, NonSecure
|
NODE.security.tl1Access.AccessState
|
NonSecure
|
Disabled, NonSecure, Secure
|
NODE.security.userLockout.FailedLoginsAllowedBeforeLockout
|
5 (times)
|
0-10
|
NODE.security.userLockout.LockoutDuration
|
00:30 (mins:secs)
|
00:00, 00:05, 00:10 .. 10:00
|
NODE.security.userLockout.ManualUnlockBySuperuser
|
FALSE
|
TRUE, FALSE
|
NODE.timing.bits-1.AdminSSMIn
|
STU
|
G811, STU, G812T, G812L, SETS, DUS
|
NODE.timing.bits-1.AISThreshold
|
DUS
|
G811, STU, G812T, G812L, SETS, DUS
|
NODE.timing.bits-1.Coding
|
HDB3
|
•HDB3, AMI when FacilityType is E1
•N/A when FacilityType is 2MHz
•AMI when FacilityType is 64kHz+8kHz
|
NODE.timing.bits-1.CodingOut
|
HDB3
|
•HDB3, AMI when FacilityTypeOut is E1
•N/A when FacilityTypeOut is 2MHz
•AMI when FacilityTypeOut is 6MHz
|
NODE.timing.bits-1.FacilityType
|
E1
|
E1, 64kHz+8kHz, 2MHz
|
NODE.timing.bits-1.FacilityTypeOut
|
E1
|
E1, 6MHz, 2MHz
|
NODE.timing.bits-1.Framing
|
FAS+CAS+CRC
|
•FAS+CRC, FAS+CAS, FAS+CAS+CRC, FAS, Unframed when FacilityType is E1
•N/A when FacilityType is 2MHz
•FAS+CRC, FAS+CAS, FAS+CAS+CRC, FAS, Unframed, Unframed-2Mhz when FacilityType is 64kHz+8kHz
|
NODE.timing.bits-1.FramingOut
|
FAS+CAS+CRC
|
•FAS+CRC, FAS+CAS, FAS+CAS+CRC, FAS, Unframed when FacilityTypeOut is E1
•N/A when FacilityTypeOut is 2MHz
•FAS+CRC, FAS+CAS, FAS+CAS+CRC, FAS, Unframed, Unframed-2Mhz when FacilityTypeOut is 6MHz
|
NODE.timing.bits-1.Sa bit
|
4
|
•4, 5, 6, 7, 8 when FacilityType is E1
•N/A when FacilityType is 2MHz
•N/A when FacilityType is 64kHz+8kHz
|
NODE.timing.bits-1.State
|
unlocked
|
unlocked, locked, disabled
|
NODE.timing.bits-1.StateOut
|
unlocked
|
unlocked, locked, disabled
|
NODE.timing.bits-2.AdminSSMIn
|
STU
|
G811, STU, G812T, G812L, SETS, DUS
|
NODE.timing.bits-2.AISThreshold
|
DUS
|
G811, STU, G812T, G812L, SETS, DUS
|
NODE.timing.bits-2.Coding
|
HDB3
|
•HDB3, AMI when FacilityType is E1
•N/A when FacilityType is 2MHz
•AMI when FacilityType is 64kHz+8kHz
|
NODE.timing.bits-2.CodingOut
|
HDB3
|
•HDB3, AMI when FacilityTypeOut is E1
•N/A when FacilityTypeOut is 2MHz
•AMI when FacilityTypeOut is 6MHz
|
NODE.timing.bits-2.FacilityType
|
E1
|
E1, 64kHz+8kHz, 2MHz
|
NODE.timing.bits-2.FacilityTypeOut
|
E1
|
E1, 6MHz, 2MHz
|
NODE.timing.bits-2.Framing
|
FAS+CAS+CRC
|
•FAS+CRC, FAS+CAS, FAS+CAS+CRC, FAS, Unframed when FacilityType is E1
•N/A when FacilityType is 2MHz
•FAS+CRC, FAS+CAS, FAS+CAS+CRC, FAS, Unframed, Unframed-2Mhz when FacilityType is 64kHz+8kHz
|
NODE.timing.bits-2.FramingOut
|
FAS+CAS+CRC
|
•FAS+CRC, FAS+CAS, FAS+CAS+CRC, FAS, Unframed when FacilityTypeOut is E1
•N/A when FacilityTypeOut is 2MHz
•FAS+CRC, FAS+CAS, FAS+CAS+CRC, FAS, Unframed, Unframed-2Mhz when FacilityTypeOut is 6MHz
|
NODE.timing.bits-2.Sa bit
|
4
|
•4, 5, 6, 7, 8 when FacilityType is E1
•N/A when FacilityType is 2MHz
•N/A when FacilityType is 64kHz+8kHz
|
NODE.timing.bits-2.State
|
unlocked
|
unlocked, locked, disabled
|
NODE.timing.bits-2.StateOut
|
unlocked
|
unlocked, locked, disabled
|
NODE.timing.general.Mode
|
External
|
External, Line, Mixed
|
NODE.timing.general.ReversionTime
|
5.0 (minutes)
|
0.5, 1.0, 1.5 .. 12.0
|
NODE.timing.general.Revertive
|
FALSE
|
TRUE, FALSE
|
D.3.2.1 Time Zones
Table D-24 lists the time zones that apply for node time zone defaults. Time zones are expressed in terms of their relative relationships to Greenwich Mean Time (GMT).
Table D-24 Time Zones (ANSI and ETSI )
Time Zone (GMT +/- Hours)
|
Location(s)
|
GMT-11:00
|
Midway Islands, Samoa
|
GMT-10:00
|
Hawaiian Islands, Tahiti
|
GMT-09:00
|
Anchorage - Alaska
|
GMT-08:00
|
Pacific Time (US & Canada), Tijuana
|
GMT-07:00
|
Mountain Time (US & Canada)
|
GMT-07:00
|
Phoenix - Arizona
|
GMT-06:00
|
Central Time (US & Canada)
|
GMT-06:00
|
Mexico City
|
GMT-06:00
|
Costa Rica, Managua, San Salvador
|
GMT-06:00
|
Saskatchewan, Manitoba
|
GMT-05:00
|
Bogota, Lima, Quito
|
GMT-05:00
|
Eastern Time (US & Canada)
|
GMT-05:00
|
Havana
|
GMT-05:00
|
Indiana (US)
|
GMT-04:00
|
Asuncion
|
GMT-04:00
|
Caracas, La Paz, San Juan
|
GMT-04:00
|
Atlantic Time (Canada), Halifax, Saint John, Charlottetown
|
GMT-04:00
|
Santiago
|
GMT-04:00
|
Thule (Qaanaaq)
|
GMT-03:30
|
St. John's - Newfoundland
|
GMT-03:00
|
Brasilia, Rio de Janeiro, Sao Paulo
|
GMT-03:00
|
Buenos Aires, Georgetown
|
GMT-03:00
|
Godthab (Nuuk) - Greenland
|
GMT-02:00
|
Mid-Atlantic
|
GMT-01:00
|
Azores, Scoresbysund
|
GMT-01:00
|
Praia - Cape Verde
|
GMT 00:00
|
Casablanca, Reykjavik, Monrovia
|
GMT
|
Greenwich Mean Time
|
GMT 00:00
|
Dublin, Edinburgh, London, Lisbon
|
GMT+01:00
|
Amsterdam, Berlin, Rome, Stockholm, Paris
|
GMT+01:00
|
Belgrade, Bratislava, Budapest, Ljubljana, Prague
|
GMT+01:00
|
Brussels, Copenhagen, Madrid, Vienna
|
GMT+01:00
|
Sarajevo, Skopje, Sofija, Vilnius, Warsaw, Zagreb
|
GMT+01:00
|
West Central Africa, Algiers, Lagos, Luanda
|
GMT+01:00
|
Windhoek (Namibia)
|
GMT+02:00
|
Al Jizah, Alexandria, Cairo
|
GMT+02:00
|
Amman
|
GMT+02:00
|
Athens, Bucharest, Istanbul
|
GMT+02:00
|
Beirut
|
GMT+02:00
|
Cape Town, Harare, Johannesburg, Pretoria
|
GMT+02:00
|
Jerusalem
|
GMT+02:00
|
Kaliningrad, Minsk
|
GMT+03:00
|
Aden, Antananarivo, Khartoum, Nairobi
|
GMT+03:00
|
Baghdad
|
GMT+03:00
|
Kuwait, Riyadh
|
GMT+03:00
|
Moscow, St. Petersburg, Novgorod
|
GMT+03:30
|
Tehran
|
GMT+04:00
|
Abu Dhabi, Mauritius, Muscat
|
GMT+04:00
|
Aqtau, T'bilisi
|
GMT+04:00
|
Baku
|
GMT+04:00
|
Yerevan, Samara
|
GMT+04:30
|
Kabul
|
GMT+05:00
|
Chelyabinsk, Prem, Yekaterinburg, Ufa
|
GMT+05:00
|
Islamabad, Karachi, Tashkent
|
GMT+05:30
|
Calcutta, Mumbai, New Delhi, Chennai
|
GMT+05:45
|
Kathmandu
|
GMT+06:00
|
Almaty
|
GMT+06:00
|
Colombo, Dhaka, Astana
|
GMT+06:00
|
Novosibirsk, Omsk
|
GMT+06:30
|
Cocos, Rangoon
|
GMT+07:00
|
Bangkok, Hanoi, Jakarta
|
GMT+07:00
|
Krasnoyarsk, Norilsk, Novokuznetsk
|
GMT+08:00
|
Irkutsk, Ulaan Bataar
|
GMT+08:00
|
Beijing, Shanghai, Hong Kong, Urumqi
|
GMT+08:00
|
Perth
|
GMT+08:00
|
Singapore, Manila, Taipei, Kuala Lumpur
|
GMT+09:00
|
Chita, Yakutsk
|
GMT+09:00
|
Osaka, Sapporo, Tokyo
|
GMT+09:00
|
Palau, Pyongyang, Seoul
|
GMT+09:30
|
Adelaide, Broken Hill
|
GMT+09:30
|
Darwin
|
GMT+10:00
|
Brisbane, Port Moresby, Guam
|
GMT+10:00
|
Canberra, Melbourne, Sydney
|
GMT+10:00
|
Hobart
|
GMT+10:00
|
Khabarovsk, Vladivostok
|
GMT+10:30
|
Lord Howe Island
|
GMT+11:00
|
Honiara, Magadan, Soloman Islands
|
GMT+11:00
|
Noumea - New Caledonia
|
GMT+11:30
|
Kingston - Norfolk Island
|
GMT+12:00
|
Andyra, Kamchatka
|
GMT+12:00
|
Auckland, Wellington
|
GMT+12:00
|
Marshall Islands, Eniwetok
|
GMT+12:00
|
Suva - Fiji
|
GMT+12:45
|
Chatham Island
|
GMT+13:00
|
Nuku'alofa - Tonga
|
GMT+13:00
|
Rawaki, Phoenix Islands
|
GMT+14:00
|
Line Islands, Kiritimati - Kiribati
|
D.3.3 ETSI CTC Default Settings
Table D-25 lists the CTC-level default settings for the Cisco ONS 15454. Cisco provides the following user-configurable defaults for CTC.
•Create circuits with the Route Automatically check box selected by default.
•Create TL1-like circuits (instructs the node to create only cross-connects, allowing the resulting circuits to be in an upgradable state).
•Choose a default network map (which country).
Table D-25 CTC Default Settings (ETSI)
Default Name
|
Default Value
|
Default Domain
|
CTC.circuits.AutoRoute
|
TRUE
|
TRUE, FALSE
|
CTC.circuits.CreateLikeTL1
|
FALSE
|
TRUE, FALSE
|
CTC.network.Map
|
United States
|
-none-, Germany, Japan, Netherlands, South Korea, United Kingdom, United States
|