cc/td/doc/product/ong/15400/r60docs
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table Of Contents

Network Element Defaults

D.1  Network Element Defaults Description

D.2  ANSI Platform Defaults

D.2.1  ANSI Card Default Settings

D.2.2  ANSI Node Default Settings

D.2.3  ANSI CTC Default Settings

D.3  ETSI Platform Defaults

D.3.1  ETSI Card Default Settings

D.3.2  ETSI Node Default Settings

D.3.3  ETSI CTC Default Settings


Network Element Defaults



Note The terms "Unidirectional Path Switched Ring" and "UPSR" may appear in Cisco literature. These terms do not refer to using Cisco ONS 15xxx products in a unidirectional path switched ring configuration. Rather, these terms, as well as "Path Protected Mesh Network" and "PPMN," refer generally to Cisco's path protection feature, which may be used in any topological network configuration. Cisco does not recommend using its path protection feature in any particular topological network configuration.


This appendix describes the factory-configured (default) network element (NE) settings for the Cisco ONS 15454. It includes descriptions of card, node, and Cisco Transport Controller (CTC) default settings. To import, export, or edit the settings, see Chapter 13, "Maintain the Node." Cards supported by this platform that are not listed in this appendix are not supported by user-configurable NE defaults settings.

To change card settings individually (that is, without changing the defaults), see "Provision Transponder and Muxponder Cards." To change node settings, see Chapter 10, "Manage the Node."


Note Unless otherwise specified, in this appendix "ONS 15454" refers to both ANSI (ONS 15454 SONET) and ETSI (ONS 15454 SDH) shelf assemblies.


D.1  Network Element Defaults Description

The NE defaults are preinstalled on each Cisco ONS 15454 TCC2 and TCC2P card. They also ship as a file called 15454-defaults.txt (ANSI shelves) or 15454SDH-defaults.txt (ETSI shelves) on the CTC software CD in case you want to import the defaults onto existing TCC2/TCC2P cards. The NE defaults include card-level, CTC, and node-level defaults.

Changes to card provisioning made manually using Change Card Settings procedures in "Provision Transponder and Muxponder Cards."override default settings. If you use the CTC Defaults editor (in the node view > Provisioning > Defaults tabs) or import a new defaults file, any changes to card or slot settings that result only affect cards that are installed or preprovisioned after the defaults have changed.

Changes made manually to most node-level default settings override the current settings, whether default or provisioned. If you change node-level default settings, either by using the Defaults editor or by importing a new defaults file, the new defaults reprovision the node immediately for all settings except those relating to protection (1+1 bidirectional switching, 1+1 reversion time, 1+1 revertive, Bidirectional Line Switched Ring [BLSR] or multiplex section-shared protection ring [MS-SPRing] reversion time, BLSR/MS-SPRing ring revertive, BLSR/MS-SPRing span reversion time, BLSR/MS-SPRing span revertive), which apply to subsequent provisioning.


Note Changing some NE defaults can cause CTC disconnection or a reboot of the node in order for the default to take effect. Before you change a default, check in the Side Effects column of the Defaults editor (right-click a column header and select Show Column > Side Effects) and be prepared for the occurrence of any side effects listed for that default.


D.2  ANSI Platform Defaults

The following sections give the NE defaults for the ONS 15454 ANSI platform. To see defaults for the ONS 15454 ETSI platform, see the "ETSI Platform Defaults" section.

D.2.1  ANSI Card Default Settings

The tables in this section list the default settings for each DWDM, TXP, and MXP card. For all other cards, including electrical, optical, Ethernet, and Fibre Channel, refer to the Cisco ONS 15454 Reference Manual.

Cisco provides user-configurable defaults for the Cisco ONS 15454 cards, including:

Soak Time—All cards. The length of time that elapses between an automaticInService (AINS) port receiving a valid signal and when it automatically changes to in-service status.

Port State—All cards. Sets the port to one of the four available states (IS, OOS, OOS_MT, or IS_AINS), depending on whether you need ports in or out of service.

SF BER Level—TXP and MXP cards. Defines the signal fail (SF) bit error rate (BER).

SD BER Level—TXP and MXP cards. Defines the signal degrade (SD) BER.

Enable Sync Messages—MXP cards. Enables synchronization status messages (SSM) (S1 byte), which allow the node to choose the best timing source.

Send Do Not Use—TXP and MXP cards. Sends a do not use (DUS) message on the S1 byte when enabled.

Payload Type—TXP and MXP cards. Defines the type of client signal.

Termination Mode—TXP and MXP cards. Defines the type of termination (line, section, or transparent).

ALS Mode—TXP and MXP cards. Sets the automatic laser shutdown (ALS) feature to one of four available states (disabled, auto restart, manual restart, manual restart for test).

ALS Recovery Interval—TXP and MXP cards. Sets the automatic laser shutdown recovery time interval.

ALS Recovery Pulse Width—TXP and MXP cards. Sets the automatic laser shutdown recovery pulse signal width.

FEC—TXP and MXP cards. Enables or disables the forward error correction (FEC) monitoring on the optical transport network.

G.709 OTN—TXP and MXP cards. Enables or disables the ITU-T G.709 monitoring on the optical transport network.

FEC Thresholds—TXP and MXP cards. Sets the performance monitoring (PM) parameters for gathering FEC performance data and detecting problems early.

Optical Thresholds—TXP and MXP cards. Sets the PM parameters for gathering physical optics performance data and detecting problems early.

OTN Thresholds—TXP and MXP cards. Sets the PM parameters for gathering OTN trunk-side performance data and detecting problems early.

PM Threshold settings—All cards. Sets the PM parameters for gathering performance data and detecting problems early.


Note For more information about each individual card setting, see "Provision Transponder and Muxponder Cards."



Note For more information about the PM parameters, see Chapter 9, "Monitor Performance."


D.2.1.1  MXP_2.5G_10E Card Default Settings

Table D-1 lists the MXP_2.5G_10E card default settings.

Table D-1 MXP_2.5G_10E Card Default Settings (ANSI) 

Default Name
Default Value
Default Domain

MXP-2_5G-10E.config.client.AINSSoakTime

08:00 (hours:mins)

00:00, 00:15, 00:30 .. 48:00

MXP-2_5G-10E.config.client.AisSquelchMode

Squelch

Ais, Squelch

MXP-2_5G-10E.config.client.AlsMode

Disabled

Disabled, Auto Restart, Manual Restart, Manual Restart for Test

MXP-2_5G-10E.config.client.AlsRecoveryPulseDuration

2.0 (seconds)

2.0, 2.1, 2.2 .. 100.0 when AlsMode is Disabled, Auto Restart, Manual Restart

80.0, 80.1, 80.2 .. 100.0 when AlsMode is Manual Restart for Test

MXP-2_5G-10E.config.client.AlsRecoveryPulseInterval

100 (seconds)

100-2000

MXP-2_5G-10E.config.client.ppmPortAssignment

OC48_PORT

UNASSIGNED, OC48_PORT

MXP-2_5G-10E.config.client.ppmSlotAssignment

UNASSIGNED

UNASSIGNED, PPM (1 Port)

MXP-2_5G-10E.config.client.SDBER

1.00E-07

1E-5, 1E-6, 1E-7, 1E-8, 1E-9

MXP-2_5G-10E.config.client.SendDoNotUse

FALSE

TRUE, FALSE

MXP-2_5G-10E.config.client.SFBER

1.00E-04

1E-3, 1E-4, 1E-5

MXP-2_5G-10E.config.client.SyncMsgIn

TRUE

FALSE, TRUE

MXP-2_5G-10E.config.client.TerminationMode

Transparent

Transparent, Section

MXP-2_5G-10E.config.trunk.AINSSoakTime

08:00 (hours:mins)

00:00, 00:15, 00:30 .. 48:00

MXP-2_5G-10E.config.trunk.AlsMode

Disabled

Disabled, Auto Restart, Manual Restart, Manual Restart for Test

MXP-2_5G-10E.config.trunk.AlsRecoveryPulseDuration

100.0 (seconds)

60.0, 60.1, 60.2 .. 200.0 when AlsMode is Disabled, Auto Restart, Manual Restart

80.0, 80.1, 80.2 .. 100.0 when AlsMode is Manual Restart for Test

MXP-2_5G-10E.config.trunk.AlsRecoveryPulseInterval

300 (seconds)

200-2000

MXP-2_5G-10E.opticalthresholds.client.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10E.opticalthresholds.client.alarm.HighRxPower

3.0 (dBm)

-21.0, -20.9, -20.8 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.alarm.HighTxPower

3.0 (dBm)

-8.0, -7.9, -7.8 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.alarm.LowRxPower

-21.0 (dBm)

-40.0, -39.9, -39.8 .. 3.0

MXP-2_5G-10E.opticalthresholds.client.alarm.LowTxPower

-8.0 (dBm)

-40.0, -39.9, -39.8 .. 3.0

MXP-2_5G-10E.opticalthresholds.client.warning.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10E.opticalthresholds.client.warning.15min.HighRxPower

2.0 (dBm)

-20.0, -19.9, -19.8 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.warning.15min.HighTxPower

2.0 (dBm)

-7.0, -6.9, -6.8 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.warning.15min.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. 2.0

MXP-2_5G-10E.opticalthresholds.client.warning.15min.LowTxPower

-7.0 (dBm)

-40.0, -39.9, -39.8 .. 2.0

MXP-2_5G-10E.opticalthresholds.client.warning.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10E.opticalthresholds.client.warning.1day.HighRxPower

2.5 (dBm)

-20.5, -20.4, -20.3 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.warning.1day.HighTxPower

2.5 (dBm)

-7.5, -7.4, -7.3 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.warning.1day.LowRxPower

-20.5 (dBm)

-40.0, -39.9, -39.8 .. 2.5

MXP-2_5G-10E.opticalthresholds.client.warning.1day.LowTxPower

-7.5 (dBm)

-40.0, -39.9, -39.8 .. 2.5

MXP-2_5G-10E.opticalthresholds.trunk.alarm.HighLaserBias

98.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10E.opticalthresholds.trunk.alarm.HighRxPower

-8.0 (dBm)

-25.0, -24.9, -24.8 .. 30.0

MXP-2_5G-10E.opticalthresholds.trunk.alarm.HighTxPower

8.0 (dBm)

1.0, 1.1, 1.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.trunk.alarm.LowRxPower

-25.0 (dBm)

-40.0, -39.9, -39.8 .. -8.0

MXP-2_5G-10E.opticalthresholds.trunk.alarm.LowTxPower

1.0 (dBm)

-40.0, -39.9, -39.8 .. 8.0

MXP-2_5G-10E.opticalthresholds.trunk.warning.15min.HighLaserBias

95.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10E.opticalthresholds.trunk.warning.15min.HighRxPower

-7.5 (dBm)

-24.5, -24.4, -24.3 .. 30.0

MXP-2_5G-10E.opticalthresholds.trunk.warning.15min.HighTxPower

7.0 (dBm)

2.0, 2.1, 2.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.trunk.warning.15min.LowRxPower

-24.5 (dBm)

-40.0, -39.9, -39.8 .. -7.5

MXP-2_5G-10E.opticalthresholds.trunk.warning.15min.LowTxPower

2.0 (dBm)

-40.0, -39.9, -39.8 .. 7.0

MXP-2_5G-10E.opticalthresholds.trunk.warning.1day.HighLaserBias

96.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10E.opticalthresholds.trunk.warning.1day.HighRxPower

-7.3 (dBm)

-24.7, -24.6, -24.5 .. 30.0

MXP-2_5G-10E.opticalthresholds.trunk.warning.1day.HighTxPower

7.0 (dBm)

2.0, 2.1, 2.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.trunk.warning.1day.LowRxPower

-24.7 (dBm)

-40.0, -39.9, -39.8 .. -7.3

MXP-2_5G-10E.opticalthresholds.trunk.warning.1day.LowTxPower

2.0 (dBm)

-40.0, -39.9, -39.8 .. 7.0

MXP-2_5G-10E.otn.fecthresholds.enhanced.15min.BitErrorsCorrected

903330 (count)

0-9033621811200

MXP-2_5G-10E.otn.fecthresholds.enhanced.15min.UncorrectableWords

5 (count)

0-4724697600

MXP-2_5G-10E.otn.fecthresholds.enhanced.1day.BitErrorsCorrected

86719680 (count)

0-867227693875200

MXP-2_5G-10E.otn.fecthresholds.enhanced.1day.UncorrectableWords

480 (count)

0-453570969600

MXP-2_5G-10E.otn.fecthresholds.standard.15min.BitErrorsCorrected

903330 (count)

0-9033621811200

MXP-2_5G-10E.otn.fecthresholds.standard.15min.UncorrectableWords

5 (count)

0-4724697600

MXP-2_5G-10E.otn.fecthresholds.standard.1day.BitErrorsCorrected

86719680 (count)

0-867227693875200

MXP-2_5G-10E.otn.fecthresholds.standard.1day.UncorrectableWords

480 (count)

0-453570969600

MXP-2_5G-10E.otn.g709thresholds.pm.farend.15min.BBE

85040 (count)

0-8850600

MXP-2_5G-10E.otn.g709thresholds.pm.farend.15min.ES

87 (seconds)

0-900

MXP-2_5G-10E.otn.g709thresholds.pm.farend.15min.FC

10 (count)

0-72

MXP-2_5G-10E.otn.g709thresholds.pm.farend.15min.SES

1 (seconds)

0-900

MXP-2_5G-10E.otn.g709thresholds.pm.farend.15min.UAS

3 (seconds)

0-900

MXP-2_5G-10E.otn.g709thresholds.pm.farend.1day.BBE

850400 (count)

0-849657600

MXP-2_5G-10E.otn.g709thresholds.pm.farend.1day.ES

864 (seconds)

0-86400

MXP-2_5G-10E.otn.g709thresholds.pm.farend.1day.FC

40 (count)

0-6912

MXP-2_5G-10E.otn.g709thresholds.pm.farend.1day.SES

4 (seconds)

0-86400

MXP-2_5G-10E.otn.g709thresholds.pm.farend.1day.UAS

10 (seconds)

0-86400

MXP-2_5G-10E.otn.g709thresholds.pm.nearend.15min.BBE

85040 (count)

0-8850600

MXP-2_5G-10E.otn.g709thresholds.pm.nearend.15min.ES

87 (seconds)

0-900

MXP-2_5G-10E.otn.g709thresholds.pm.nearend.15min.FC

10 (count)

0-72

MXP-2_5G-10E.otn.g709thresholds.pm.nearend.15min.SES

1 (seconds)

0-900

MXP-2_5G-10E.otn.g709thresholds.pm.nearend.15min.UAS

3 (seconds)

0-900

MXP-2_5G-10E.otn.g709thresholds.pm.nearend.1day.BBE

850400 (count)

0-849657600

MXP-2_5G-10E.otn.g709thresholds.pm.nearend.1day.ES

864 (seconds)

0-86400

MXP-2_5G-10E.otn.g709thresholds.pm.nearend.1day.FC

40 (count)

0-6912

MXP-2_5G-10E.otn.g709thresholds.pm.nearend.1day.SES

4 (seconds)

0-86400

MXP-2_5G-10E.otn.g709thresholds.pm.nearend.1day.UAS

10 (seconds)

0-86400

MXP-2_5G-10E.otn.g709thresholds.sm.farend.15min.BBE

10000 (count)

0-8850600

MXP-2_5G-10E.otn.g709thresholds.sm.farend.15min.ES

500 (seconds)

0-900

MXP-2_5G-10E.otn.g709thresholds.sm.farend.15min.FC

10 (count)

0-72

MXP-2_5G-10E.otn.g709thresholds.sm.farend.15min.SES

500 (seconds)

0-900

MXP-2_5G-10E.otn.g709thresholds.sm.farend.15min.UAS

500 (seconds)

0-900

MXP-2_5G-10E.otn.g709thresholds.sm.farend.1day.BBE

100000 (count)

0-849657600

MXP-2_5G-10E.otn.g709thresholds.sm.farend.1day.ES

5000 (seconds)

0-86400

MXP-2_5G-10E.otn.g709thresholds.sm.farend.1day.FC

40 (count)

0-6912

MXP-2_5G-10E.otn.g709thresholds.sm.farend.1day.SES

5000 (seconds)

0-86400

MXP-2_5G-10E.otn.g709thresholds.sm.farend.1day.UAS

5000 (seconds)

0-86400

MXP-2_5G-10E.otn.g709thresholds.sm.nearend.15min.BBE

10000 (count)

0-8850600

MXP-2_5G-10E.otn.g709thresholds.sm.nearend.15min.ES

500 (seconds)

0-900

MXP-2_5G-10E.otn.g709thresholds.sm.nearend.15min.FC

10 (count)

0-72

MXP-2_5G-10E.otn.g709thresholds.sm.nearend.15min.SES

500 (seconds)

0-900

MXP-2_5G-10E.otn.g709thresholds.sm.nearend.15min.UAS

500 (seconds)

0-900

MXP-2_5G-10E.otn.g709thresholds.sm.nearend.1day.BBE

100000 (count)

0-849657600

MXP-2_5G-10E.otn.g709thresholds.sm.nearend.1day.ES

5000 (seconds)

0-86400

MXP-2_5G-10E.otn.g709thresholds.sm.nearend.1day.FC

40 (count)

0-6912

MXP-2_5G-10E.otn.g709thresholds.sm.nearend.1day.SES

5000 (seconds)

0-86400

MXP-2_5G-10E.otn.g709thresholds.sm.nearend.1day.UAS

5000 (seconds)

0-86400

MXP-2_5G-10E.otn.otnLines.AsynchSynchMapping

ODU Multiplex

ODU Multiplex

MXP-2_5G-10E.otn.otnLines.FEC

Standard

Disable, Standard, Enhanced

MXP-2_5G-10E.otn.otnLines.G709OTN

Enable

Enable

MXP-2_5G-10E.otn.otnLines.SDBER

1.00E-07

1E-5, 1E-6, 1E-7, 1E-8, 1E-9

MXP-2_5G-10E.pmthresholds.client.line.farend.15min.CV

21260 (B2 count)

0-2212200

MXP-2_5G-10E.pmthresholds.client.line.farend.15min.ES

87 (seconds)

0-900

MXP-2_5G-10E.pmthresholds.client.line.farend.15min.FC

10 (count)

0-72

MXP-2_5G-10E.pmthresholds.client.line.farend.15min.SES

1 (seconds)

0-900

MXP-2_5G-10E.pmthresholds.client.line.farend.15min.UAS

3 (seconds)

0-900

MXP-2_5G-10E.pmthresholds.client.line.farend.1day.CV

212600 (B2 count)

0-212371200

MXP-2_5G-10E.pmthresholds.client.line.farend.1day.ES

864 (seconds)

0-86400

MXP-2_5G-10E.pmthresholds.client.line.farend.1day.FC

40 (count)

0-6912

MXP-2_5G-10E.pmthresholds.client.line.farend.1day.SES

4 (seconds)

0-86400

MXP-2_5G-10E.pmthresholds.client.line.farend.1day.UAS

10 (seconds)

0-86400

MXP-2_5G-10E.pmthresholds.client.line.nearend.15min.CV

21260 (B2 count)

0-2212200

MXP-2_5G-10E.pmthresholds.client.line.nearend.15min.ES

87 (seconds)

0-900

MXP-2_5G-10E.pmthresholds.client.line.nearend.15min.FC

10 (count)

0-72

MXP-2_5G-10E.pmthresholds.client.line.nearend.15min.SES

1 (seconds)

0-900

MXP-2_5G-10E.pmthresholds.client.line.nearend.15min.UAS

3 (seconds)

0-900

MXP-2_5G-10E.pmthresholds.client.line.nearend.1day.CV

212600 (B2 count)

0-212371200

MXP-2_5G-10E.pmthresholds.client.line.nearend.1day.ES

864 (seconds)

0-86400

MXP-2_5G-10E.pmthresholds.client.line.nearend.1day.FC

40 (count)

0-6912

MXP-2_5G-10E.pmthresholds.client.line.nearend.1day.SES

4 (seconds)

0-86400

MXP-2_5G-10E.pmthresholds.client.line.nearend.1day.UAS

10 (seconds)

0-86400

MXP-2_5G-10E.pmthresholds.client.section.nearend.15min.CV

10000 (B1 count)

0-2151900

MXP-2_5G-10E.pmthresholds.client.section.nearend.15min.ES

500 (seconds)

0-900

MXP-2_5G-10E.pmthresholds.client.section.nearend.15min.SEFS

500 (seconds)

0-900

MXP-2_5G-10E.pmthresholds.client.section.nearend.15min.SES

500 (seconds)

0-900

MXP-2_5G-10E.pmthresholds.client.section.nearend.1day.CV

100000 (B1 count)

0-206582400

MXP-2_5G-10E.pmthresholds.client.section.nearend.1day.ES

5000 (seconds)

0-86400

MXP-2_5G-10E.pmthresholds.client.section.nearend.1day.SEFS

5000 (seconds)

0-86400

MXP-2_5G-10E.pmthresholds.client.section.nearend.1day.SES

5000 (seconds)

0-86400


D.2.1.2  MXP_2.5G_10G Card Default Settings

Table D-2 lists the MXP_2.5G_10G card default settings.

Table D-2 MXP_2.5G_10G Card Default Settings (ANSI) 

Default Name
Default Value
Default Domain

MXP-2_5G-10G.config.client.AINSSoakTime

08:00 (hours:mins)

00:00, 00:15, 00:30 .. 48:00

MXP-2_5G-10G.config.client.AlsMode

Disabled

Disabled, Auto Restart, Manual Restart, Manual Restart for Test

MXP-2_5G-10G.config.client.AlsRecoveryPulseDuration

4.0 (seconds)

2.0, 2.1, 2.2 .. 100.0 when AlsMode is Disabled, Auto Restart, Manual Restart

80.0, 80.1, 80.2 .. 100.0 when AlsMode is Manual Restart for Test

MXP-2_5G-10G.config.client.AlsRecoveryPulseInterval

100 (seconds)

60-300

MXP-2_5G-10G.config.client.ppmPortAssignment

OC48_PORT

UNASSIGNED, OC48_PORT

MXP-2_5G-10G.config.client.ppmSlotAssignment

UNASSIGNED

UNASSIGNED, PPM (1 Port)

MXP-2_5G-10G.config.client.SDBER

1.00E-07

1E-5, 1E-6, 1E-7, 1E-8, 1E-9

MXP-2_5G-10G.config.client.SendDoNotUse

FALSE

TRUE, FALSE

MXP-2_5G-10G.config.client.SFBER

1.00E-04

1E-3, 1E-4, 1E-5

MXP-2_5G-10G.config.client.SyncMsgIn

TRUE

FALSE, TRUE

MXP-2_5G-10G.config.client.TerminationMode

Transparent

Transparent, Line

MXP-2_5G-10G.config.trunk.AINSSoakTime

08:00 (hours:mins)

00:00, 00:15, 00:30 .. 48:00

MXP-2_5G-10G.config.trunk.AlsMode

Disabled

Disabled, Auto Restart, Manual Restart, Manual Restart for Test

MXP-2_5G-10G.config.trunk.AlsRecoveryPulseDuration

4.0 (seconds)

2.0, 2.1, 2.2 .. 100.0 when AlsMode is Disabled, Auto Restart, Manual Restart

80.0, 80.1, 80.2 .. 100.0 when AlsMode is Manual Restart for Test

MXP-2_5G-10G.config.trunk.AlsRecoveryPulseInterval

100 (seconds)

60-300

MXP-2_5G-10G.opticalthresholds.client.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10G.opticalthresholds.client.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.alarm.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.alarm.LowRxPower

-21.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10G.opticalthresholds.client.alarm.LowTxPower

-8.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10G.opticalthresholds.client.warning.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10G.opticalthresholds.client.warning.15min.HighRxPower

2.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.warning.15min.HighTxPower

2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.warning.15min.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10G.opticalthresholds.client.warning.15min.LowTxPower

-7.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10G.opticalthresholds.client.warning.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10G.opticalthresholds.client.warning.1day.HighRxPower

2.5 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.warning.1day.HighTxPower

2.5 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.warning.1day.LowRxPower

-20.5 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10G.opticalthresholds.client.warning.1day.LowTxPower

-7.5 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10G.opticalthresholds.trunk.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10G.opticalthresholds.trunk.alarm.HighRxPower

-8.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.trunk.alarm.HighTxPower

4.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.trunk.alarm.LowRxPower

-25.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10G.opticalthresholds.trunk.alarm.LowTxPower

2.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10G.opticalthresholds.trunk.warning.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10G.opticalthresholds.trunk.warning.15min.HighRxPower

-7.5 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.trunk.warning.15min.HighTxPower

3.5 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.trunk.warning.15min.LowRxPower

-24.5 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10G.opticalthresholds.trunk.warning.15min.LowTxPower

2.5 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10G.opticalthresholds.trunk.warning.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10G.opticalthresholds.trunk.warning.1day.HighRxPower

-7.3 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.trunk.warning.1day.HighTxPower

3.7 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.trunk.warning.1day.LowRxPower

-24.7 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10G.opticalthresholds.trunk.warning.1day.LowTxPower

2.3 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10G.otn.fecthresholds.standard.15min.BitErrorsCorrected

903330 (count)

0-9033621811200

MXP-2_5G-10G.otn.fecthresholds.standard.15min.UncorrectableWords

5 (count)

0-4724697600

MXP-2_5G-10G.otn.fecthresholds.standard.1day.BitErrorsCorrected

86719680 (count)

0-867227693875200

MXP-2_5G-10G.otn.fecthresholds.standard.1day.UncorrectableWords

480 (count)

0-453570969600

MXP-2_5G-10G.otn.g709thresholds.pm.farend.15min.BBE

85040 (count)

0-8850600

MXP-2_5G-10G.otn.g709thresholds.pm.farend.15min.ES

87 (seconds)

0-900

MXP-2_5G-10G.otn.g709thresholds.pm.farend.15min.FC

10 (count)

0-72

MXP-2_5G-10G.otn.g709thresholds.pm.farend.15min.SES

1 (seconds)

0-900

MXP-2_5G-10G.otn.g709thresholds.pm.farend.15min.UAS

3 (seconds)

0-900

MXP-2_5G-10G.otn.g709thresholds.pm.farend.1day.BBE

850400 (count)

0-849657600

MXP-2_5G-10G.otn.g709thresholds.pm.farend.1day.ES

864 (seconds)

0-86400

MXP-2_5G-10G.otn.g709thresholds.pm.farend.1day.FC

40 (count)

0-6912

MXP-2_5G-10G.otn.g709thresholds.pm.farend.1day.SES

4 (seconds)

0-86400

MXP-2_5G-10G.otn.g709thresholds.pm.farend.1day.UAS

10 (seconds)

0-86400

MXP-2_5G-10G.otn.g709thresholds.pm.nearend.15min.BBE

85040 (count)

0-8850600

MXP-2_5G-10G.otn.g709thresholds.pm.nearend.15min.ES

87 (seconds)

0-900

MXP-2_5G-10G.otn.g709thresholds.pm.nearend.15min.FC

10 (count)

0-72

MXP-2_5G-10G.otn.g709thresholds.pm.nearend.15min.SES

1 (seconds)

0-900

MXP-2_5G-10G.otn.g709thresholds.pm.nearend.15min.UAS

3 (seconds)

0-900

MXP-2_5G-10G.otn.g709thresholds.pm.nearend.1day.BBE

850400 (count)

0-849657600

MXP-2_5G-10G.otn.g709thresholds.pm.nearend.1day.ES

864 (seconds)

0-86400

MXP-2_5G-10G.otn.g709thresholds.pm.nearend.1day.FC

40 (count)

0-6912

MXP-2_5G-10G.otn.g709thresholds.pm.nearend.1day.SES

4 (seconds)

0-86400

MXP-2_5G-10G.otn.g709thresholds.pm.nearend.1day.UAS

10 (seconds)

0-86400

MXP-2_5G-10G.otn.g709thresholds.sm.farend.15min.BBE

10000 (count)

0-8850600

MXP-2_5G-10G.otn.g709thresholds.sm.farend.15min.ES

500 (seconds)

0-900

MXP-2_5G-10G.otn.g709thresholds.sm.farend.15min.FC

10 (count)

0-72

MXP-2_5G-10G.otn.g709thresholds.sm.farend.15min.SES

500 (seconds)

0-900

MXP-2_5G-10G.otn.g709thresholds.sm.farend.15min.UAS

500 (seconds)

0-900

MXP-2_5G-10G.otn.g709thresholds.sm.farend.1day.BBE

100000 (count)

0-849657600

MXP-2_5G-10G.otn.g709thresholds.sm.farend.1day.ES

5000 (seconds)

0-86400

MXP-2_5G-10G.otn.g709thresholds.sm.farend.1day.FC

40 (count)

0-6912

MXP-2_5G-10G.otn.g709thresholds.sm.farend.1day.SES

5000 (seconds)

0-86400

MXP-2_5G-10G.otn.g709thresholds.sm.farend.1day.UAS

5000 (seconds)

0-86400

MXP-2_5G-10G.otn.g709thresholds.sm.nearend.15min.BBE

10000 (count)

0-8850600

MXP-2_5G-10G.otn.g709thresholds.sm.nearend.15min.ES

500 (seconds)

0-900

MXP-2_5G-10G.otn.g709thresholds.sm.nearend.15min.FC

10 (count)

0-72

MXP-2_5G-10G.otn.g709thresholds.sm.nearend.15min.SES

500 (seconds)

0-900

MXP-2_5G-10G.otn.g709thresholds.sm.nearend.15min.UAS

500 (seconds)

0-900

MXP-2_5G-10G.otn.g709thresholds.sm.nearend.1day.BBE

100000 (count)

0-849657600

MXP-2_5G-10G.otn.g709thresholds.sm.nearend.1day.ES

5000 (seconds)

0-86400

MXP-2_5G-10G.otn.g709thresholds.sm.nearend.1day.FC

40 (count)

0-6912

MXP-2_5G-10G.otn.g709thresholds.sm.nearend.1day.SES

5000 (seconds)

0-86400

MXP-2_5G-10G.otn.g709thresholds.sm.nearend.1day.UAS

5000 (seconds)

0-86400

MXP-2_5G-10G.otn.otnLines.FEC

Standard

Disable, Standard, Enhanced when G709OTN is Enable

Disable when G709OTN is Disable

MXP-2_5G-10G.otn.otnLines.G709OTN

Enable

Disable, Enable

MXP-2_5G-10G.otn.otnLines.SDBER

1.00E-07

1E-5, 1E-6, 1E-7, 1E-8, 1E-9

MXP-2_5G-10G.pmthresholds.client.line.farend.15min.CV

21260 (B2 count)

0-2212200

MXP-2_5G-10G.pmthresholds.client.line.farend.15min.ES

87 (seconds)

0-900

MXP-2_5G-10G.pmthresholds.client.line.farend.15min.FC

10 (count)

0-72

MXP-2_5G-10G.pmthresholds.client.line.farend.15min.SES

1 (seconds)

0-900

MXP-2_5G-10G.pmthresholds.client.line.farend.15min.UAS

3 (seconds)

0-900

MXP-2_5G-10G.pmthresholds.client.line.farend.1day.CV

212600 (B2 count)

0-212371200

MXP-2_5G-10G.pmthresholds.client.line.farend.1day.ES

864 (seconds)

0-86400

MXP-2_5G-10G.pmthresholds.client.line.farend.1day.FC

40 (count)

0-6912

MXP-2_5G-10G.pmthresholds.client.line.farend.1day.SES

4 (seconds)

0-86400

MXP-2_5G-10G.pmthresholds.client.line.farend.1day.UAS

10 (seconds)

0-86400

MXP-2_5G-10G.pmthresholds.client.line.nearend.15min.CV

21260 (B2 count)

0-2212200

MXP-2_5G-10G.pmthresholds.client.line.nearend.15min.ES

87 (seconds)

0-900

MXP-2_5G-10G.pmthresholds.client.line.nearend.15min.FC

10 (count)

0-72

MXP-2_5G-10G.pmthresholds.client.line.nearend.15min.SES

1 (seconds)

0-900

MXP-2_5G-10G.pmthresholds.client.line.nearend.15min.UAS

3 (seconds)

0-900

MXP-2_5G-10G.pmthresholds.client.line.nearend.1day.CV

212600 (B2 count)

0-212371200

MXP-2_5G-10G.pmthresholds.client.line.nearend.1day.ES

864 (seconds)

0-86400

MXP-2_5G-10G.pmthresholds.client.line.nearend.1day.FC

40 (count)

0-6912

MXP-2_5G-10G.pmthresholds.client.line.nearend.1day.SES

4 (seconds)

0-86400

MXP-2_5G-10G.pmthresholds.client.line.nearend.1day.UAS

10 (seconds)

0-86400

MXP-2_5G-10G.pmthresholds.client.section.nearend.15min.CV

10000 (B1 count)

0-2151900

MXP-2_5G-10G.pmthresholds.client.section.nearend.15min.ES

500 (seconds)

0-900

MXP-2_5G-10G.pmthresholds.client.section.nearend.15min.SEFS

500 (seconds)

0-900

MXP-2_5G-10G.pmthresholds.client.section.nearend.15min.SES

500 (seconds)

0-900

MXP-2_5G-10G.pmthresholds.client.section.nearend.1day.CV

100000 (B1 count)

0-206582400

MXP-2_5G-10G.pmthresholds.client.section.nearend.1day.ES

5000 (seconds)

0-86400

MXP-2_5G-10G.pmthresholds.client.section.nearend.1day.SEFS

5000 (seconds)

0-86400

MXP-2_5G-10G.pmthresholds.client.section.nearend.1day.SES

5000 (seconds)

0-86400

MXP-2_5G-10G.pmthresholds.trunk.line.farend.15min.CV

85040 (B2 count)

0-8850600

MXP-2_5G-10G.pmthresholds.trunk.line.farend.15min.ES

87 (seconds)

0-900

MXP-2_5G-10G.pmthresholds.trunk.line.farend.15min.FC

10 (count)

0-72

MXP-2_5G-10G.pmthresholds.trunk.line.farend.15min.SES

1 (seconds)

0-900

MXP-2_5G-10G.pmthresholds.trunk.line.farend.15min.UAS

3 (seconds)

0-900

MXP-2_5G-10G.pmthresholds.trunk.line.farend.1day.CV

850400 (B2 count)

0-849657600

MXP-2_5G-10G.pmthresholds.trunk.line.farend.1day.ES

864 (seconds)

0-86400

MXP-2_5G-10G.pmthresholds.trunk.line.farend.1day.FC

40 (count)

0-6912

MXP-2_5G-10G.pmthresholds.trunk.line.farend.1day.SES

4 (seconds)

0-86400

MXP-2_5G-10G.pmthresholds.trunk.line.farend.1day.UAS

10 (seconds)

0-86400

MXP-2_5G-10G.pmthresholds.trunk.line.nearend.15min.CV

85040 (B2 count)

0-8850600

MXP-2_5G-10G.pmthresholds.trunk.line.nearend.15min.ES

87 (seconds)

0-900

MXP-2_5G-10G.pmthresholds.trunk.line.nearend.15min.FC

10 (count)

0-72

MXP-2_5G-10G.pmthresholds.trunk.line.nearend.15min.SES

1 (seconds)

0-900

MXP-2_5G-10G.pmthresholds.trunk.line.nearend.15min.UAS

3 (seconds)

0-900

MXP-2_5G-10G.pmthresholds.trunk.line.nearend.1day.CV

850400 (B2 count)

0-849657600

MXP-2_5G-10G.pmthresholds.trunk.line.nearend.1day.ES

864 (seconds)

0-86400

MXP-2_5G-10G.pmthresholds.trunk.line.nearend.1day.FC

40 (count)

0-6912

MXP-2_5G-10G.pmthresholds.trunk.line.nearend.1day.SES

4 (seconds)

0-86400

MXP-2_5G-10G.pmthresholds.trunk.line.nearend.1day.UAS

10 (seconds)

0-86400

MXP-2_5G-10G.pmthresholds.trunk.section.nearend.15min.CV

10000 (B1 count)

0-7967700

MXP-2_5G-10G.pmthresholds.trunk.section.nearend.15min.ES

500 (seconds)

0-900

MXP-2_5G-10G.pmthresholds.trunk.section.nearend.15min.SEFS

500 (seconds)

0-900

MXP-2_5G-10G.pmthresholds.trunk.section.nearend.15min.SES

500 (seconds)

0-900

MXP-2_5G-10G.pmthresholds.trunk.section.nearend.1day.CV

100000 (B1 count)

0-764899200

MXP-2_5G-10G.pmthresholds.trunk.section.nearend.1day.ES

5000 (seconds)

0-86400

MXP-2_5G-10G.pmthresholds.trunk.section.nearend.1day.SEFS

5000 (seconds)

0-86400

MXP-2_5G-10G.pmthresholds.trunk.section.nearend.1day.SES

5000 (seconds)

0-86400


D.2.1.3  MXP_MR_2.5G Card Default Settings

Table D-3 lists the MXP_MR_2.5G card default settings.

Table D-3 MXP_MR_2.5G Card Default Settings (ANSI) 

Default Name
Default Value
Default Domain

MXP-MR-2_5G.config.client.AlsMode

Disabled

Disabled, Manual Restart, Manual Restart for Test

MXP-MR-2_5G.config.client.AlsRecoveryPulseDuration

4.0 (seconds)

2.0, 2.1, 2.2 .. 100.0 when AlsMode is Disabled, Auto Restart, Manual Restart

80.0, 80.1, 80.2 .. 100.0 when AlsMode is Manual Restart for Test

MXP-MR-2_5G.config.client.AlsRecoveryPulseInterval

100 (seconds)

60-300

MXP-MR-2_5G.config.client.ppmPortAssignment

UNASSIGNED

UNASSIGNED, ONE_GE, FC1G ISL, FC2G ISL, FICON1G ISL, FICON2G ISL

MXP-MR-2_5G.config.client.ppmSlotAssignment

UNASSIGNED

UNASSIGNED, PPM (1 Port)

MXP-MR-2_5G.config.fc.distanceExtension.AutoadjustGFPBufferThreshold

TRUE

TRUE, FALSE

MXP-MR-2_5G.config.fc.distanceExtension.AutoDetect

TRUE

TRUE, FALSE

MXP-MR-2_5G.config.fc.distanceExtension.Enabled

TRUE

TRUE, FALSE

MXP-MR-2_5G.config.fc.distanceExtension.NumCredits

32

2-256

MXP-MR-2_5G.config.fc.distanceExtension.NumGFPBuffers

16

16, 32, 48 .. 1200

MXP-MR-2_5G.config.fc.enhancedFibreChannelFicon.MaxFrameSize

2148

2148, 2152, 2156, 2160, 2164, 2168, 2172

MXP-MR-2_5G.config.trunk.AINSSoakTime

08:00 (hours:mins)

00:00, 00:15, 00:30 .. 48:00

MXP-MR-2_5G.config.trunk.AlsMode

Disabled

Disabled, Auto Restart, Manual Restart, Manual Restart for Test

MXP-MR-2_5G.config.trunk.AlsRecoveryPulseDuration

4.0 (seconds)

2.0, 2.1, 2.2 .. 100.0 when AlsMode is Disabled, Auto Restart, Manual Restart

80.0, 80.1, 80.2 .. 100.0 when AlsMode is Manual Restart for Test

MXP-MR-2_5G.config.trunk.AlsRecoveryPulseInterval

100 (seconds)

60-300

MXP-MR-2_5G.config.trunk.SDBER

1.00E-07

1E-5, 1E-6, 1E-7, 1E-8, 1E-9

MXP-MR-2_5G.config.trunk.SendDoNotUse

FALSE

TRUE, FALSE

MXP-MR-2_5G.config.trunk.SFBER

1.00E-04

1E-3, 1E-4, 1E-5

MXP-MR-2_5G.config.trunk.SyncMsgIn

TRUE

FALSE, TRUE

MXP-MR-2_5G.opticalthresholds.client.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.alarm.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.alarm.LowRxPower

-21.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.alarm.LowTxPower

-8.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.warning.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.warning.15min.HighRxPower

2.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.warning.15min.HighTxPower

2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.warning.15min.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.warning.15min.LowTxPower

-7.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.warning.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.warning.1day.HighRxPower

2.5 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.warning.1day.HighTxPower

2.5 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.warning.1day.LowRxPower

-20.5 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.warning.1day.LowTxPower

-7.5 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.trunk.alarm.HighLaserBias

98.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.trunk.alarm.HighRxPower

-8.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.trunk.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.trunk.alarm.LowRxPower

-25.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.trunk.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.trunk.warning.15min.HighLaserBias

95.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.trunk.warning.15min.HighRxPower

-7.5 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.trunk.warning.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.trunk.warning.15min.LowRxPower

-24.5 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.trunk.warning.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.trunk.warning.1day.HighLaserBias

96.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.trunk.warning.1day.HighRxPower

-7.3 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.trunk.warning.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.trunk.warning.1day.LowRxPower

-24.7 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.trunk.warning.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.pmthresholds.trunk.line.farend.15min.CV

21260 (B2 count)

0-2212200

MXP-MR-2_5G.pmthresholds.trunk.line.farend.15min.ES

87 (seconds)

0-900

MXP-MR-2_5G.pmthresholds.trunk.line.farend.15min.FC

10 (count)

0-72

MXP-MR-2_5G.pmthresholds.trunk.line.farend.15min.SES

1 (seconds)

0-900

MXP-MR-2_5G.pmthresholds.trunk.line.farend.15min.UAS

3 (seconds)

0-900

MXP-MR-2_5G.pmthresholds.trunk.line.farend.1day.CV

212600 (B2 count)

0-212371200

MXP-MR-2_5G.pmthresholds.trunk.line.farend.1day.ES

864 (seconds)

0-86400

MXP-MR-2_5G.pmthresholds.trunk.line.farend.1day.FC

40 (count)

0-6912

MXP-MR-2_5G.pmthresholds.trunk.line.farend.1day.SES

4 (seconds)

0-86400

MXP-MR-2_5G.pmthresholds.trunk.line.farend.1day.UAS

10 (seconds)

0-86400

MXP-MR-2_5G.pmthresholds.trunk.line.nearend.15min.CV

21260 (B2 count)

0-2212200

MXP-MR-2_5G.pmthresholds.trunk.line.nearend.15min.ES

87 (seconds)

0-900

MXP-MR-2_5G.pmthresholds.trunk.line.nearend.15min.FC

10 (count)

0-72

MXP-MR-2_5G.pmthresholds.trunk.line.nearend.15min.SES

1 (seconds)

0-900

MXP-MR-2_5G.pmthresholds.trunk.line.nearend.15min.UAS

3 (seconds)

0-900

MXP-MR-2_5G.pmthresholds.trunk.line.nearend.1day.CV

212600 (B2 count)

0-212371200

MXP-MR-2_5G.pmthresholds.trunk.line.nearend.1day.ES

864 (seconds)

0-86400

MXP-MR-2_5G.pmthresholds.trunk.line.nearend.1day.FC

40 (count)

0-6912

MXP-MR-2_5G.pmthresholds.trunk.line.nearend.1day.SES

4 (seconds)

0-86400

MXP-MR-2_5G.pmthresholds.trunk.line.nearend.1day.UAS

10 (seconds)

0-86400

MXP-MR-2_5G.pmthresholds.trunk.section.nearend.15min.CV

10000 (B1 count)

0-2151900

MXP-MR-2_5G.pmthresholds.trunk.section.nearend.15min.ES

500 (seconds)

0-900

MXP-MR-2_5G.pmthresholds.trunk.section.nearend.15min.SEFS

500 (seconds)

0-900

MXP-MR-2_5G.pmthresholds.trunk.section.nearend.15min.SES

500 (seconds)

0-900

MXP-MR-2_5G.pmthresholds.trunk.section.nearend.1day.CV

100000 (B1 count)

0-206582400

MXP-MR-2_5G.pmthresholds.trunk.section.nearend.1day.ES

5000 (seconds)

0-86400

MXP-MR-2_5G.pmthresholds.trunk.section.nearend.1day.SEFS

5000 (seconds)

0-86400

MXP-MR-2_5G.pmthresholds.trunk.section.nearend.1day.SES

5000 (seconds)

0-86400


D.2.1.4  MXPP_MR_2.5G Card Default Settings

Table D-4 lists the MXPP_MR_2.5G card default settings.

Table D-4 MXPP_MR_2.5G Card Default Settings (ANSI) 

Default Name
Default Value
Default Domain

MXPP-MR-2_5G.config.client.AlsMode

Disabled

Disabled, Manual Restart, Manual Restart for Test

MXPP-MR-2_5G.config.client.AlsRecoveryPulseDuration

4.0 (seconds)

2.0, 2.1, 2.2 .. 100.0 when AlsMode is Disabled, Auto Restart, Manual Restart

80.0, 80.1, 80.2 .. 100.0 when AlsMode is Manual Restart for Test

MXPP-MR-2_5G.config.client.AlsRecoveryPulseInterval

100 (seconds)

60-300

MXPP-MR-2_5G.config.client.ppmPortAssignment

UNASSIGNED

UNASSIGNED, ONE_GE, FC1G ISL, FC2G ISL, FICON1G ISL, FICON2G ISL

MXPP-MR-2_5G.config.client.ppmSlotAssignment

UNASSIGNED

UNASSIGNED, PPM (1 Port)

MXPP-MR-2_5G.config.fc.distanceExtension.AutoadjustGFPBufferThreshold

TRUE

TRUE, FALSE

MXPP-MR-2_5G.config.fc.distanceExtension.AutoDetect

TRUE

TRUE, FALSE

MXPP-MR-2_5G.config.fc.distanceExtension.Enabled

TRUE

TRUE, FALSE

MXPP-MR-2_5G.config.fc.distanceExtension.NumCredits

32

2-256

MXPP-MR-2_5G.config.fc.distanceExtension.NumGFPBuffers

16

16, 32, 48 .. 1200

MXPP-MR-2_5G.config.fc.enhancedFibreChannelFicon.MaxFrameSize

2148

2148, 2152, 2156, 2160, 2164, 2168, 2172

MXPP-MR-2_5G.config.trunk.AINSSoakTime

08:00 (hours:mins)

00:00, 00:15, 00:30 .. 48:00

MXPP-MR-2_5G.config.trunk.AlsMode

Disabled

Disabled, Auto Restart, Manual Restart, Manual Restart for Test

MXPP-MR-2_5G.config.trunk.AlsRecoveryPulseDuration

4.0 (seconds)

2.0, 2.1, 2.2 .. 100.0 when AlsMode is Disabled, Auto Restart, Manual Restart

80.0, 80.1, 80.2 .. 100.0 when AlsMode is Manual Restart for Test

MXPP-MR-2_5G.config.trunk.AlsRecoveryPulseInterval

100 (seconds)

60-300

MXPP-MR-2_5G.config.trunk.SDBER

1.00E-07

1E-5, 1E-6, 1E-7, 1E-8, 1E-9

MXPP-MR-2_5G.config.trunk.SFBER

1.00E-04

1E-3, 1E-4, 1E-5

MXPP-MR-2_5G.opticalthresholds.client.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.alarm.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.alarm.LowRxPower

-21.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.alarm.LowTxPower

-8.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.warning.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.warning.15min.HighRxPower

2.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.warning.15min.HighTxPower

2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.warning.15min.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.warning.15min.LowTxPower

-7.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.warning.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.warning.1day.HighRxPower

2.5 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.warning.1day.HighTxPower

2.5 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.warning.1day.LowRxPower

-20.5 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.warning.1day.LowTxPower

-7.5 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.trunk.alarm.HighLaserBias

98.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.trunk.alarm.HighRxPower

-8.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.trunk.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.trunk.alarm.LowRxPower

-25.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.trunk.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.trunk.warning.15min.HighLaserBias

95.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.trunk.warning.15min.HighRxPower

-7.5 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.trunk.warning.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.trunk.warning.15min.LowRxPower

-24.5 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.trunk.warning.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.trunk.warning.1day.HighLaserBias

96.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.trunk.warning.1day.HighRxPower

-7.3 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.trunk.warning.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.trunk.warning.1day.LowRxPower

-24.7 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.trunk.warning.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.pmthresholds.trunk.line.farend.15min.CV

21260 (B2 count)

0-2212200

MXPP-MR-2_5G.pmthresholds.trunk.line.farend.15min.ES

87 (seconds)

0-900

MXPP-MR-2_5G.pmthresholds.trunk.line.farend.15min.FC

10 (count)

0-72

MXPP-MR-2_5G.pmthresholds.trunk.line.farend.15min.SES

1 (seconds)

0-900

MXPP-MR-2_5G.pmthresholds.trunk.line.farend.15min.UAS

3 (seconds)

0-900

MXPP-MR-2_5G.pmthresholds.trunk.line.farend.1day.CV

212600 (B2 count)

0-212371200

MXPP-MR-2_5G.pmthresholds.trunk.line.farend.1day.ES

864 (seconds)

0-86400

MXPP-MR-2_5G.pmthresholds.trunk.line.farend.1day.FC

40 (count)

0-6912

MXPP-MR-2_5G.pmthresholds.trunk.line.farend.1day.SES

4 (seconds)

0-86400

MXPP-MR-2_5G.pmthresholds.trunk.line.farend.1day.UAS

10 (seconds)

0-86400

MXPP-MR-2_5G.pmthresholds.trunk.line.nearend.15min.CV

21260 (B2 count)

0-2212200

MXPP-MR-2_5G.pmthresholds.trunk.line.nearend.15min.ES

87 (seconds)

0-900

MXPP-MR-2_5G.pmthresholds.trunk.line.nearend.15min.FC

10 (count)

0-72

MXPP-MR-2_5G.pmthresholds.trunk.line.nearend.15min.SES

1 (seconds)

0-900

MXPP-MR-2_5G.pmthresholds.trunk.line.nearend.15min.UAS

3 (seconds)

0-900

MXPP-MR-2_5G.pmthresholds.trunk.line.nearend.1day.CV

212600 (B2 count)

0-212371200

MXPP-MR-2_5G.pmthresholds.trunk.line.nearend.1day.ES

864 (seconds)

0-86400

MXPP-MR-2_5G.pmthresholds.trunk.line.nearend.1day.FC

40 (count)

0-6912

MXPP-MR-2_5G.pmthresholds.trunk.line.nearend.1day.SES

4 (seconds)

0-86400

MXPP-MR-2_5G.pmthresholds.trunk.line.nearend.1day.UAS

10 (seconds)

0-86400

MXPP-MR-2_5G.pmthresholds.trunk.section.nearend.15min.CV

10000 (B1 count)

0-2151900

MXPP-MR-2_5G.pmthresholds.trunk.section.nearend.15min.ES

500 (seconds)

0-900

MXPP-MR-2_5G.pmthresholds.trunk.section.nearend.15min.SEFS

500 (seconds)

0-900

MXPP-MR-2_5G.pmthresholds.trunk.section.nearend.15min.SES

500 (seconds)

0-900

MXPP-MR-2_5G.pmthresholds.trunk.section.nearend.1day.CV

100000 (B1 count)

0-206582400

MXPP-MR-2_5G.pmthresholds.trunk.section.nearend.1day.ES

5000 (seconds)

0-86400

MXPP-MR-2_5G.pmthresholds.trunk.section.nearend.1day.SEFS

5000 (seconds)

0-86400

MXPP-MR-2_5G.pmthresholds.trunk.section.nearend.1day.SES

5000 (seconds)

0-86400


D.2.1.5  TXP_MR_10E Card Default Settings

Table D-5 lists the TXP_MR_10E card default settings.

Table D-5 TXP_MR_10E Card Default Settings (ANSI) 

Default Name
Default Value
Default Domain

TXP-MR-10E.config.client.AINSSoakTime

08:00 (hours:mins)

00:00, 00:15, 00:30 .. 48:00

TXP-MR-10E.config.client.AisSquelchMode

Squelch

Ais, Squelch

TXP-MR-10E.config.client.AlsMode

Disabled

Disabled, Auto Restart, Manual Restart, Manual Restart for Test

TXP-MR-10E.config.client.AlsRecoveryPulseDuration

2.0 (seconds)

2.0, 2.1, 2.2 .. 100.0 when AlsMode is Disabled, Auto Restart, Manual Restart

80.0, 80.1, 80.2 .. 100.0 when AlsMode is Manual Restart for Test

TXP-MR-10E.config.client.AlsRecoveryPulseInterval

100 (seconds)

100-2000

TXP-MR-10E.config.client.ppmPortAssignment

UNASSIGNED

UNASSIGNED, SONET (including 10G Ethernet WAN Phy), 10G Ethernet LAN Phy, 10G Fiber Channel

TXP-MR-10E.config.client.ppmSlotAssignment

UNASSIGNED

UNASSIGNED, PPM (1 Port)

TXP-MR-10E.config.client.SDBER

1.00E-07

1E-5, 1E-6, 1E-7, 1E-8, 1E-9

TXP-MR-10E.config.client.SendDoNotUse

FALSE

TRUE, FALSE

TXP-MR-10E.config.client.SFBER

1.00E-04

1E-3, 1E-4, 1E-5

TXP-MR-10E.config.client.SyncMsgIn

TRUE

FALSE, TRUE

TXP-MR-10E.config.client.TerminationMode

Transparent

Transparent, Line when ppmPortAssignment is UNASSIGNED, SONET (including 10G Ethernet WAN Phy)

Transparent when ppmPortAssignment is 10G Ethernet LAN Phy, 10G Fiber Channel

TXP-MR-10E.config.trunk.AINSSoakTime

08:00 (hours:mins)

00:00, 00:15, 00:30 .. 48:00

TXP-MR-10E.config.trunk.AlsMode

Disabled

Disabled, Auto Restart, Manual Restart, Manual Restart for Test

TXP-MR-10E.config.trunk.AlsRecoveryPulseDuration

100.0 (seconds)

6.0, 6.1, 6.2 .. 200.0 when AlsMode is Disabled, Auto Restart, Manual Restart

80.0, 80.1, 80.2 .. 100.0 when AlsMode is Manual Restart for Test

TXP-MR-10E.config.trunk.AlsRecoveryPulseInterval

300 (seconds)

200-2000

TXP-MR-10E.config.trunk.SDBER

1.00E-07

1E-5, 1E-6, 1E-7, 1E-8, 1E-9

TXP-MR-10E.config.trunk.SFBER

1.00E-04

1E-3, 1E-4, 1E-5

TXP-MR-10E.opticalthresholds.client.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.alarm.HighRxPower

2.0 (dBm)

-17.0, -16.9, -16.8 .. 30.0

TXP-MR-10E.opticalthresholds.client.alarm.HighTxPower

2.0 (dBm)

-9.0, -8.9, -8.8 .. 30.0

TXP-MR-10E.opticalthresholds.client.alarm.LowRxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. 2.0

TXP-MR-10E.opticalthresholds.client.alarm.LowTxPower

-9.0 (dBm)

-40.0, -39.9, -39.8 .. 2.0

TXP-MR-10E.opticalthresholds.client.warning.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.warning.15min.HighRxPower

1.0 (dBm)

-16.0, -15.9, -15.8 .. 30.0

TXP-MR-10E.opticalthresholds.client.warning.15min.HighTxPower

1.0 (dBm)

-8.0, -7.9, -7.8 .. 30.0

TXP-MR-10E.opticalthresholds.client.warning.15min.LowRxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. 1.0

TXP-MR-10E.opticalthresholds.client.warning.15min.LowTxPower

-8.0 (dBm)

-40.0, -39.9, -39.8 .. 1.0

TXP-MR-10E.opticalthresholds.client.warning.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.warning.1day.HighRxPower

1.5 (dBm)

-16.5, -16.4, -16.3 .. 30.0

TXP-MR-10E.opticalthresholds.client.warning.1day.HighTxPower

1.5 (dBm)

-8.5, -8.4, -8.3 .. 30.0

TXP-MR-10E.opticalthresholds.client.warning.1day.LowRxPower

-16.5 (dBm)

-40.0, -39.9, -39.8 .. 1.5

TXP-MR-10E.opticalthresholds.client.warning.1day.LowTxPower

-8.5 (dBm)

-40.0, -39.9, -39.8 .. 1.5

TXP-MR-10E.opticalthresholds.trunk.alarm.HighLaserBias

98.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.trunk.alarm.HighRxPower

-8.0 (dBm)

-25.0, -24.9, -24.8 .. 30.0

TXP-MR-10E.opticalthresholds.trunk.alarm.HighTxPower

8.0 (dBm)

1.0, 1.1, 1.2 .. 30.0

TXP-MR-10E.opticalthresholds.trunk.alarm.LowRxPower

-25.0 (dBm)

-40.0, -39.9, -39.8 .. -8.0

TXP-MR-10E.opticalthresholds.trunk.alarm.LowTxPower

1.0 (dBm)

-40.0, -39.9, -39.8 .. 8.0

TXP-MR-10E.opticalthresholds.trunk.warning.15min.HighLaserBias

95.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.trunk.warning.15min.HighRxPower

-7.5 (dBm)

-24.5, -24.4, -24.3 .. 30.0

TXP-MR-10E.opticalthresholds.trunk.warning.15min.HighTxPower

7.0 (dBm)

2.0, 2.1, 2.2 .. 30.0

TXP-MR-10E.opticalthresholds.trunk.warning.15min.LowRxPower

-24.5 (dBm)

-40.0, -39.9, -39.8 .. -7.5

TXP-MR-10E.opticalthresholds.trunk.warning.15min.LowTxPower

2.0 (dBm)

-40.0, -39.9, -39.8 .. 7.0

TXP-MR-10E.opticalthresholds.trunk.warning.1day.HighLaserBias

96.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.trunk.warning.1day.HighRxPower

-7.3 (dBm)

-24.7, -24.6, -24.5 .. 30.0

TXP-MR-10E.opticalthresholds.trunk.warning.1day.HighTxPower

7.0 (dBm)

2.0, 2.1, 2.2 .. 30.0

TXP-MR-10E.opticalthresholds.trunk.warning.1day.LowRxPower

-24.7 (dBm)

-40.0, -39.9, -39.8 .. -7.3

TXP-MR-10E.opticalthresholds.trunk.warning.1day.LowTxPower

2.0 (dBm)

-40.0, -39.9, -39.8 .. 7.0

TXP-MR-10E.otn.fecthresholds.enhanced.15min.BitErrorsCorrected

903330 (count)

0-9033621811200

TXP-MR-10E.otn.fecthresholds.enhanced.15min.UncorrectableWords

5 (count)

0-4724697600

TXP-MR-10E.otn.fecthresholds.enhanced.1day.BitErrorsCorrected

86719680 (count)

0-867227693875200

TXP-MR-10E.otn.fecthresholds.enhanced.1day.UncorrectableWords

480 (count)

0-453570969600

TXP-MR-10E.otn.fecthresholds.standard.15min.BitErrorsCorrected

903330 (count)

0-9033621811200

TXP-MR-10E.otn.fecthresholds.standard.15min.UncorrectableWords

5 (count)

0-4724697600

TXP-MR-10E.otn.fecthresholds.standard.1day.BitErrorsCorrected

86719680 (count)

0-867227693875200

TXP-MR-10E.otn.fecthresholds.standard.1day.UncorrectableWords

480 (count)

0-453570969600

TXP-MR-10E.otn.g709thresholds.pm.farend.15min.BBE

85040 (count)

0-8850600

TXP-MR-10E.otn.g709thresholds.pm.farend.15min.ES

87 (seconds)

0-900

TXP-MR-10E.otn.g709thresholds.pm.farend.15min.FC

10 (count)

0-72

TXP-MR-10E.otn.g709thresholds.pm.farend.15min.SES

1 (seconds)

0-900

TXP-MR-10E.otn.g709thresholds.pm.farend.15min.UAS

3 (seconds)

0-900

TXP-MR-10E.otn.g709thresholds.pm.farend.1day.BBE

850400 (count)

0-849657600

TXP-MR-10E.otn.g709thresholds.pm.farend.1day.ES

864 (seconds)

0-86400

TXP-MR-10E.otn.g709thresholds.pm.farend.1day.FC

40 (count)

0-6912

TXP-MR-10E.otn.g709thresholds.pm.farend.1day.SES

4 (seconds)

0-86400

TXP-MR-10E.otn.g709thresholds.pm.farend.1day.UAS

10 (seconds)

0-86400

TXP-MR-10E.otn.g709thresholds.pm.nearend.15min.BBE

85040 (count)

0-8850600

TXP-MR-10E.otn.g709thresholds.pm.nearend.15min.ES

87 (seconds)

0-900

TXP-MR-10E.otn.g709thresholds.pm.nearend.15min.FC

10 (count)

0-72

TXP-MR-10E.otn.g709thresholds.pm.nearend.15min.SES

1 (seconds)

0-900

TXP-MR-10E.otn.g709thresholds.pm.nearend.15min.UAS

3 (seconds)

0-900

TXP-MR-10E.otn.g709thresholds.pm.nearend.1day.BBE

850400 (count)

0-849657600

TXP-MR-10E.otn.g709thresholds.pm.nearend.1day.ES

864 (seconds)

0-86400

TXP-MR-10E.otn.g709thresholds.pm.nearend.1day.FC

40 (count)

0-6912

TXP-MR-10E.otn.g709thresholds.pm.nearend.1day.SES

4 (seconds)

0-86400

TXP-MR-10E.otn.g709thresholds.pm.nearend.1day.UAS

10 (seconds)

0-86400

TXP-MR-10E.otn.g709thresholds.sm.farend.15min.BBE

10000 (count)

0-8850600

TXP-MR-10E.otn.g709thresholds.sm.farend.15min.ES

500 (seconds)

0-900

TXP-MR-10E.otn.g709thresholds.sm.farend.15min.FC

10 (count)

0-72

TXP-MR-10E.otn.g709thresholds.sm.farend.15min.SES

500 (seconds)

0-900

TXP-MR-10E.otn.g709thresholds.sm.farend.15min.UAS

500 (seconds)

0-900

TXP-MR-10E.otn.g709thresholds.sm.farend.1day.BBE

100000 (count)

0-849657600

TXP-MR-10E.otn.g709thresholds.sm.farend.1day.ES

5000 (seconds)

0-86400

TXP-MR-10E.otn.g709thresholds.sm.farend.1day.FC

40 (count)

0-6912

TXP-MR-10E.otn.g709thresholds.sm.farend.1day.SES

5000 (seconds)

0-86400

TXP-MR-10E.otn.g709thresholds.sm.farend.1day.UAS

5000 (seconds)

0-86400

TXP-MR-10E.otn.g709thresholds.sm.nearend.15min.BBE

10000 (count)

0-8850600

TXP-MR-10E.otn.g709thresholds.sm.nearend.15min.ES

500 (seconds)

0-900

TXP-MR-10E.otn.g709thresholds.sm.nearend.15min.FC

10 (count)

0-72

TXP-MR-10E.otn.g709thresholds.sm.nearend.15min.SES

500 (seconds)

0-900

TXP-MR-10E.otn.g709thresholds.sm.nearend.15min.UAS

500 (seconds)

0-900

TXP-MR-10E.otn.g709thresholds.sm.nearend.1day.BBE

100000 (count)

0-849657600

TXP-MR-10E.otn.g709thresholds.sm.nearend.1day.ES

5000 (seconds)

0-86400

TXP-MR-10E.otn.g709thresholds.sm.nearend.1day.FC

40 (count)

0-6912

TXP-MR-10E.otn.g709thresholds.sm.nearend.1day.SES

5000 (seconds)

0-86400

TXP-MR-10E.otn.g709thresholds.sm.nearend.1day.UAS

5000 (seconds)

0-86400

TXP-MR-10E.otn.otnLines.AsynchSynchMapping

Synch Mapping

Asynch mapping, Synch Mapping

TXP-MR-10E.otn.otnLines.FEC

Standard

Disable, Standard, Enhanced when G709OTN is Enable

Disable when G709OTN is Disable

TXP-MR-10E.otn.otnLines.G709OTN

Enable

Disable, Enable

TXP-MR-10E.otn.otnLines.SDBER

1.00E-07

1E-5, 1E-6, 1E-7, 1E-8, 1E-9

TXP-MR-10E.pmthresholds.client.line.farend.15min.CV

85040 (B2 count)

0-8850600

TXP-MR-10E.pmthresholds.client.line.farend.15min.ES

87 (seconds)

0-900

TXP-MR-10E.pmthresholds.client.line.farend.15min.FC

10 (count)

0-72

TXP-MR-10E.pmthresholds.client.line.farend.15min.SES

1 (seconds)

0-900

TXP-MR-10E.pmthresholds.client.line.farend.15min.UAS

3 (seconds)

0-900

TXP-MR-10E.pmthresholds.client.line.farend.1day.CV

850400 (B2 count)

0-849657600

TXP-MR-10E.pmthresholds.client.line.farend.1day.ES

864 (seconds)

0-86400

TXP-MR-10E.pmthresholds.client.line.farend.1day.FC

40 (count)

0-6912

TXP-MR-10E.pmthresholds.client.line.farend.1day.SES

4 (seconds)

0-86400

TXP-MR-10E.pmthresholds.client.line.farend.1day.UAS

10 (seconds)

0-86400

TXP-MR-10E.pmthresholds.client.line.nearend.15min.CV

85040 (B2 count)

0-8850600

TXP-MR-10E.pmthresholds.client.line.nearend.15min.ES

87 (seconds)

0-900

TXP-MR-10E.pmthresholds.client.line.nearend.15min.FC

10 (count)

0-72

TXP-MR-10E.pmthresholds.client.line.nearend.15min.SES

1 (seconds)

0-900

TXP-MR-10E.pmthresholds.client.line.nearend.15min.UAS

3 (seconds)

0-900

TXP-MR-10E.pmthresholds.client.line.nearend.1day.CV

850400 (B2 count)

0-849657600

TXP-MR-10E.pmthresholds.client.line.nearend.1day.ES

864 (seconds)

0-86400

TXP-MR-10E.pmthresholds.client.line.nearend.1day.FC

40 (count)

0-6912

TXP-MR-10E.pmthresholds.client.line.nearend.1day.SES

4 (seconds)

0-86400

TXP-MR-10E.pmthresholds.client.line.nearend.1day.UAS

10 (seconds)

0-86400

TXP-MR-10E.pmthresholds.client.section.nearend.15min.CV

10000 (B1 count)

0-7967700

TXP-MR-10E.pmthresholds.client.section.nearend.15min.ES

500 (seconds)

0-900

TXP-MR-10E.pmthresholds.client.section.nearend.15min.SEFS

500 (seconds)

0-900

TXP-MR-10E.pmthresholds.client.section.nearend.15min.SES

500 (seconds)

0-900

TXP-MR-10E.pmthresholds.client.section.nearend.1day.CV

100000 (B1 count)

0-764899200

TXP-MR-10E.pmthresholds.client.section.nearend.1day.ES

5000 (seconds)

0-86400

TXP-MR-10E.pmthresholds.client.section.nearend.1day.SEFS

5000 (seconds)

0-86400

TXP-MR-10E.pmthresholds.client.section.nearend.1day.SES

5000 (seconds)

0-86400

TXP-MR-10E.pmthresholds.trunk.line.farend.15min.CV

85040 (B2 count)

0-8850600

TXP-MR-10E.pmthresholds.trunk.line.farend.15min.ES

87 (seconds)

0-900

TXP-MR-10E.pmthresholds.trunk.line.farend.15min.FC

10 (count)

0-72

TXP-MR-10E.pmthresholds.trunk.line.farend.15min.SES

1 (seconds)

0-900

TXP-MR-10E.pmthresholds.trunk.line.farend.15min.UAS

3 (seconds)

0-900

TXP-MR-10E.pmthresholds.trunk.line.farend.1day.CV

850400 (B2 count)

0-849657600

TXP-MR-10E.pmthresholds.trunk.line.farend.1day.ES

864 (seconds)

0-86400

TXP-MR-10E.pmthresholds.trunk.line.farend.1day.FC

40 (count)

0-6912

TXP-MR-10E.pmthresholds.trunk.line.farend.1day.SES

4 (seconds)

0-86400

TXP-MR-10E.pmthresholds.trunk.line.farend.1day.UAS

10 (seconds)

0-86400

TXP-MR-10E.pmthresholds.trunk.line.nearend.15min.CV

85040 (B2 count)

0-8850600

TXP-MR-10E.pmthresholds.trunk.line.nearend.15min.ES

87 (seconds)

0-900

TXP-MR-10E.pmthresholds.trunk.line.nearend.15min.FC

10 (count)

0-72

TXP-MR-10E.pmthresholds.trunk.line.nearend.15min.SES

1 (seconds)

0-900

TXP-MR-10E.pmthresholds.trunk.line.nearend.15min.UAS

3 (seconds)

0-900

TXP-MR-10E.pmthresholds.trunk.line.nearend.1day.CV

850400 (B2 count)

0-849657600

TXP-MR-10E.pmthresholds.trunk.line.nearend.1day.ES

864 (seconds)

0-86400

TXP-MR-10E.pmthresholds.trunk.line.nearend.1day.FC

40 (count)

0-6912

TXP-MR-10E.pmthresholds.trunk.line.nearend.1day.SES

4 (seconds)

0-86400

TXP-MR-10E.pmthresholds.trunk.line.nearend.1day.UAS

10 (seconds)

0-86400

TXP-MR-10E.pmthresholds.trunk.section.nearend.15min.CV

10000 (B1 count)

0-7967700

TXP-MR-10E.pmthresholds.trunk.section.nearend.15min.ES

500 (seconds)

0-900

TXP-MR-10E.pmthresholds.trunk.section.nearend.15min.SEFS

500 (seconds)

0-900

TXP-MR-10E.pmthresholds.trunk.section.nearend.15min.SES

500 (seconds)

0-900

TXP-MR-10E.pmthresholds.trunk.section.nearend.1day.CV

100000 (B1 count)

0-764899200

TXP-MR-10E.pmthresholds.trunk.section.nearend.1day.ES

5000 (seconds)

0-86400

TXP-MR-10E.pmthresholds.trunk.section.nearend.1day.SEFS

5000 (seconds)

0-86400

TXP-MR-10E.pmthresholds.trunk.section.nearend.1day.SES

5000 (seconds)

0-86400


D.2.1.6  TXP_MR_10G Card Default Settings

Table D-6 lists the TXP_MR_10G card default settings.

Table D-6 TXP_MR_10G Card Default Settings (ANSI) 

Default Name
Default Value
Default Domain

TXP-MR-10G.config.client.AINSSoakTime

08:00 (hours:mins)

00:00, 00:15, 00:30 .. 48:00

TXP-MR-10G.config.client.AlsMode

Disabled

Disabled, Auto Restart, Manual Restart, Manual Restart for Test

TXP-MR-10G.config.client.AlsRecoveryPulseDuration

4.0 (seconds)

2.0, 2.1, 2.2 .. 100.0 when AlsMode is Disabled, Auto Restart, Manual Restart

80.0, 80.1, 80.2 .. 100.0 when AlsMode is Manual Restart for Test

TXP-MR-10G.config.client.AlsRecoveryPulseInterval

100 (seconds)

60-300

TXP-MR-10G.config.client.mrPortAssignment

UNASSIGNED

UNASSIGNED, SONET (including 10G Ethernet WAN Phy), 10G Ethernet LAN Phy

TXP-MR-10G.config.client.SDBER

1.00E-07

1E-5, 1E-6, 1E-7, 1E-8, 1E-9

TXP-MR-10G.config.client.SFBER

1.00E-04

1E-3, 1E-4, 1E-5

TXP-MR-10G.config.client.TerminationMode

Transparent

Transparent, Line when mrPortAssignment is UNASSIGNED, SONET (including 10G Ethernet WAN Phy)

Transparent when mrPortAssignment is 10G Ethernet LAN Phy

TXP-MR-10G.config.trunk.AINSSoakTime

08:00 (hours:mins)

00:00, 00:15, 00:30 .. 48:00

TXP-MR-10G.config.trunk.AlsMode

Disabled

Disabled, Auto Restart, Manual Restart, Manual Restart for Test

TXP-MR-10G.config.trunk.AlsRecoveryPulseDuration

4.0 (seconds)

2.0, 2.1, 2.2 .. 100.0 when AlsMode is Disabled, Auto Restart, Manual Restart

80.0, 80.1, 80.2 .. 100.0 when AlsMode is Manual Restart for Test

TXP-MR-10G.config.trunk.AlsRecoveryPulseInterval

100 (seconds)

60-300

TXP-MR-10G.config.trunk.SDBER

1.00E-07

1E-5, 1E-6, 1E-7, 1E-8, 1E-9

TXP-MR-10G.config.trunk.SFBER

1.00E-04

1E-3, 1E-4, 1E-5

TXP-MR-10G.opticalthresholds.client.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10G.opticalthresholds.client.alarm.HighRxPower

2.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10G.opticalthresholds.client.alarm.HighTxPower

2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10G.opticalthresholds.client.alarm.LowRxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10G.opticalthresholds.client.alarm.LowTxPower

-9.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10G.opticalthresholds.client.warning.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10G.opticalthresholds.client.warning.15min.HighRxPower

1.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10G.opticalthresholds.client.warning.15min.HighTxPower

1.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10G.opticalthresholds.client.warning.15min.LowRxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10G.opticalthresholds.client.warning.15min.LowTxPower

-8.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10G.opticalthresholds.client.warning.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10G.opticalthresholds.client.warning.1day.HighRxPower

1.5 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10G.opticalthresholds.client.warning.1day.HighTxPower

1.5 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10G.opticalthresholds.client.warning.1day.LowRxPower

-16.5 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10G.opticalthresholds.client.warning.1day.LowTxPower

-8.5 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10G.opticalthresholds.trunk.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10G.opticalthresholds.trunk.alarm.HighRxPower

-8.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10G.opticalthresholds.trunk.alarm.HighTxPower

4.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10G.opticalthresholds.trunk.alarm.LowRxPower

-25.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10G.opticalthresholds.trunk.alarm.LowTxPower

2.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10G.opticalthresholds.trunk.warning.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10G.opticalthresholds.trunk.warning.15min.HighRxPower

-7.5 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10G.opticalthresholds.trunk.warning.15min.HighTxPower

3.5 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10G.opticalthresholds.trunk.warning.15min.LowRxPower

-24.5 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10G.opticalthresholds.trunk.warning.15min.LowTxPower

2.5 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10G.opticalthresholds.trunk.warning.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10G.opticalthresholds.trunk.warning.1day.HighRxPower

-7.3 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10G.opticalthresholds.trunk.warning.1day.HighTxPower

3.7 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10G.opticalthresholds.trunk.warning.1day.LowRxPower

-24.7 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10G.opticalthresholds.trunk.warning.1day.LowTxPower

2.3 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10G.otn.fecthresholds.standard.15min.BitErrorsCorrected

903330 (count)

0-9033621811200

TXP-MR-10G.otn.fecthresholds.standard.15min.UncorrectableWords

5 (count)

0-4724697600

TXP-MR-10G.otn.fecthresholds.standard.1day.BitErrorsCorrected

86719680 (count)

0-867227693875200

TXP-MR-10G.otn.fecthresholds.standard.1day.UncorrectableWords

480 (count)

0-453570969600

TXP-MR-10G.otn.g709thresholds.pm.farend.15min.BBE

85040 (count)

0-8850600

TXP-MR-10G.otn.g709thresholds.pm.farend.15min.ES

87 (seconds)

0-900

TXP-MR-10G.otn.g709thresholds.pm.farend.15min.FC

10 (count)

0-72

TXP-MR-10G.otn.g709thresholds.pm.farend.15min.SES

1 (seconds)

0-900

TXP-MR-10G.otn.g709thresholds.pm.farend.15min.UAS

3 (seconds)

0-900

TXP-MR-10G.otn.g709thresholds.pm.farend.1day.BBE

850400 (count)

0-849657600

TXP-MR-10G.otn.g709thresholds.pm.farend.1day.ES

864 (seconds)

0-86400

TXP-MR-10G.otn.g709thresholds.pm.farend.1day.FC

40 (count)

0-6912

TXP-MR-10G.otn.g709thresholds.pm.farend.1day.SES

4 (seconds)

0-86400

TXP-MR-10G.otn.g709thresholds.pm.farend.1day.UAS

10 (seconds)

0-86400

TXP-MR-10G.otn.g709thresholds.pm.nearend.15min.BBE

85040 (count)

0-8850600

TXP-MR-10G.otn.g709thresholds.pm.nearend.15min.ES

87 (seconds)

0-900

TXP-MR-10G.otn.g709thresholds.pm.nearend.15min.FC

10 (count)

0-72

TXP-MR-10G.otn.g709thresholds.pm.nearend.15min.SES

1 (seconds)

0-900

TXP-MR-10G.otn.g709thresholds.pm.nearend.15min.UAS

3 (seconds)

0-900

TXP-MR-10G.otn.g709thresholds.pm.nearend.1day.BBE

850400 (count)

0-849657600

TXP-MR-10G.otn.g709thresholds.pm.nearend.1day.ES

864 (seconds)

0-86400

TXP-MR-10G.otn.g709thresholds.pm.nearend.1day.FC

40 (count)

0-6912

TXP-MR-10G.otn.g709thresholds.pm.nearend.1day.SES

4 (seconds)

0-86400

TXP-MR-10G.otn.g709thresholds.pm.nearend.1day.UAS

10 (seconds)

0-86400

TXP-MR-10G.otn.g709thresholds.sm.farend.15min.BBE

10000 (count)

0-8850600

TXP-MR-10G.otn.g709thresholds.sm.farend.15min.ES

500 (seconds)

0-900

TXP-MR-10G.otn.g709thresholds.sm.farend.15min.FC

10 (count)

0-72

TXP-MR-10G.otn.g709thresholds.sm.farend.15min.SES

500 (seconds)

0-900

TXP-MR-10G.otn.g709thresholds.sm.farend.15min.UAS

500 (seconds)

0-900

TXP-MR-10G.otn.g709thresholds.sm.farend.1day.BBE

100000 (count)

0-849657600

TXP-MR-10G.otn.g709thresholds.sm.farend.1day.ES

5000 (seconds)

0-86400

TXP-MR-10G.otn.g709thresholds.sm.farend.1day.FC

40 (count)

0-6912

TXP-MR-10G.otn.g709thresholds.sm.farend.1day.SES

5000 (seconds)

0-86400

TXP-MR-10G.otn.g709thresholds.sm.farend.1day.UAS

5000 (seconds)

0-86400

TXP-MR-10G.otn.g709thresholds.sm.nearend.15min.BBE

10000 (count)

0-8850600

TXP-MR-10G.otn.g709thresholds.sm.nearend.15min.ES

500 (seconds)

0-900

TXP-MR-10G.otn.g709thresholds.sm.nearend.15min.FC

10 (count)

0-72

TXP-MR-10G.otn.g709thresholds.sm.nearend.15min.SES

500 (seconds)

0-900

TXP-MR-10G.otn.g709thresholds.sm.nearend.15min.UAS

500 (seconds)

0-900

TXP-MR-10G.otn.g709thresholds.sm.nearend.1day.BBE

100000 (count)

0-849657600

TXP-MR-10G.otn.g709thresholds.sm.nearend.1day.ES

5000 (seconds)

0-86400

TXP-MR-10G.otn.g709thresholds.sm.nearend.1day.FC

40 (count)

0-6912

TXP-MR-10G.otn.g709thresholds.sm.nearend.1day.SES

5000 (seconds)

0-86400

TXP-MR-10G.otn.g709thresholds.sm.nearend.1day.UAS

5000 (seconds)

0-86400

TXP-MR-10G.otn.otnLines.FEC

Enable

Disable, Enable when G709OTN is Enable

Disable when G709OTN is Disable

TXP-MR-10G.otn.otnLines.G709OTN

Enable

Disable, Enable

TXP-MR-10G.otn.otnLines.SDBER

1.00E-07

1E-5, 1E-6, 1E-7, 1E-8, 1E-9

TXP-MR-10G.pmthresholds.client.line.farend.15min.CV

85040 (B2 count)

0-8850600

TXP-MR-10G.pmthresholds.client.line.farend.15min.ES

87 (seconds)

0-900

TXP-MR-10G.pmthresholds.client.line.farend.15min.FC

10 (count)

0-72

TXP-MR-10G.pmthresholds.client.line.farend.15min.SES

1 (seconds)

0-900

TXP-MR-10G.pmthresholds.client.line.farend.15min.UAS

3 (seconds)

0-900

TXP-MR-10G.pmthresholds.client.line.farend.1day.CV

850400 (B2 count)

0-849657600

TXP-MR-10G.pmthresholds.client.line.farend.1day.ES

864 (seconds)

0-86400

TXP-MR-10G.pmthresholds.client.line.farend.1day.FC

40 (count)

0-6912

TXP-MR-10G.pmthresholds.client.line.farend.1day.SES

4 (seconds)

0-86400

TXP-MR-10G.pmthresholds.client.line.farend.1day.UAS

10 (seconds)

0-86400

TXP-MR-10G.pmthresholds.client.line.nearend.15min.CV

85040 (B2 count)

0-8850600

TXP-MR-10G.pmthresholds.client.line.nearend.15min.ES

87 (seconds)

0-900

TXP-MR-10G.pmthresholds.client.line.nearend.15min.FC

10 (count)

0-72

TXP-MR-10G.pmthresholds.client.line.nearend.15min.SES

1 (seconds)

0-900

TXP-MR-10G.pmthresholds.client.line.nearend.15min.UAS

3 (seconds)

0-900

TXP-MR-10G.pmthresholds.client.line.nearend.1day.CV

850400 (B2 count)

0-849657600

TXP-MR-10G.pmthresholds.client.line.nearend.1day.ES

864 (seconds)

0-86400

TXP-MR-10G.pmthresholds.client.line.nearend.1day.FC

40 (count)

0-6912

TXP-MR-10G.pmthresholds.client.line.nearend.1day.SES

4 (seconds)

0-86400

TXP-MR-10G.pmthresholds.client.line.nearend.1day.UAS

10 (seconds)

0-86400

TXP-MR-10G.pmthresholds.client.section.nearend.15min.CV

10000 (B1 count)

0-7967700

TXP-MR-10G.pmthresholds.client.section.nearend.15min.ES

500 (seconds)

0-900

TXP-MR-10G.pmthresholds.client.section.nearend.15min.SEFS

500 (seconds)

0-900

TXP-MR-10G.pmthresholds.client.section.nearend.15min.SES

500 (seconds)

0-900

TXP-MR-10G.pmthresholds.client.section.nearend.1day.CV

100000 (B1 count)

0-764899200

TXP-MR-10G.pmthresholds.client.section.nearend.1day.ES

5000 (seconds)

0-86400

TXP-MR-10G.pmthresholds.client.section.nearend.1day.SEFS

5000 (seconds)

0-86400

TXP-MR-10G.pmthresholds.client.section.nearend.1day.SES

5000 (seconds)

0-86400

TXP-MR-10G.pmthresholds.trunk.line.farend.15min.CV

85040 (B2 count)

0-8850600

TXP-MR-10G.pmthresholds.trunk.line.farend.15min.ES

87 (seconds)

0-900

TXP-MR-10G.pmthresholds.trunk.line.farend.15min.FC

10 (count)

0-72

TXP-MR-10G.pmthresholds.trunk.line.farend.15min.SES

1 (seconds)

0-900

TXP-MR-10G.pmthresholds.trunk.line.farend.15min.UAS

3 (seconds)

0-900

TXP-MR-10G.pmthresholds.trunk.line.farend.1day.CV

850400 (B2 count)

0-849657600

TXP-MR-10G.pmthresholds.trunk.line.farend.1day.ES

864 (seconds)

0-86400

TXP-MR-10G.pmthresholds.trunk.line.farend.1day.FC

40 (count)

0-6912

TXP-MR-10G.pmthresholds.trunk.line.farend.1day.SES

4 (seconds)

0-86400

TXP-MR-10G.pmthresholds.trunk.line.farend.1day.UAS

10 (seconds)

0-86400

TXP-MR-10G.pmthresholds.trunk.line.nearend.15min.CV

85040 (B2 count)

0-8850600

TXP-MR-10G.pmthresholds.trunk.line.nearend.15min.ES

87 (seconds)

0-900

TXP-MR-10G.pmthresholds.trunk.line.nearend.15min.FC

10 (count)

0-72

TXP-MR-10G.pmthresholds.trunk.line.nearend.15min.SES

1 (seconds)

0-900

TXP-MR-10G.pmthresholds.trunk.line.nearend.15min.UAS

3 (seconds)

0-900

TXP-MR-10G.pmthresholds.trunk.line.nearend.1day.CV

850400 (B2 count)

0-849657600

TXP-MR-10G.pmthresholds.trunk.line.nearend.1day.ES

864 (seconds)

0-86400

TXP-MR-10G.pmthresholds.trunk.line.nearend.1day.FC

40 (count)

0-6912

TXP-MR-10G.pmthresholds.trunk.line.nearend.1day.SES

4 (seconds)

0-86400

TXP-MR-10G.pmthresholds.trunk.line.nearend.1day.UAS

10 (seconds)

0-86400

TXP-MR-10G.pmthresholds.trunk.section.nearend.15min.CV

10000 (B1 count)

0-7967700

TXP-MR-10G.pmthresholds.trunk.section.nearend.15min.ES

500 (seconds)

0-900

TXP-MR-10G.pmthresholds.trunk.section.nearend.15min.SEFS

500 (seconds)

0-900

TXP-MR-10G.pmthresholds.trunk.section.nearend.15min.SES

500 (seconds)

0-900

TXP-MR-10G.pmthresholds.trunk.section.nearend.1day.CV

100000 (B1 count)

0-764899200

TXP-MR-10G.pmthresholds.trunk.section.nearend.1day.ES

5000 (seconds)

0-86400

TXP-MR-10G.pmthresholds.trunk.section.nearend.1day.SEFS

5000 (seconds)

0-86400

TXP-MR-10G.pmthresholds.trunk.section.nearend.1day.SES

5000 (seconds)

0-86400


D.2.1.7  TXP_MR_2.5G Card Default Settings

Table D-7 lists the TXP_MR_2.5G card default settings.

Table D-7 TXP_MR_2.5G Card Default Settings (ANSI) 

Default Name
Default Value
Default Domain

TXP-MR-2_5G.config.client.AINSSoakTime

08:00 (hours:mins)

00:00, 00:15, 00:30 .. 48:00

TXP-MR-2_5G.config.client.AlsMode

Disabled

Disabled, Auto Restart, Manual Restart, Manual Restart for Test

TXP-MR-2_5G.config.client.AlsRecoveryPulseDuration

40.0 (seconds)

2.0, 2.1, 2.2 .. 100.0 when AlsMode is Disabled, Auto Restart, Manual Restart

80.0, 80.1, 80.2 .. 100.0 when AlsMode is Manual Restart for Test

TXP-MR-2_5G.config.client.AlsRecoveryPulseInterval

100 (seconds)

60-300

TXP-MR-2_5G.config.client.ppmPortAssignment

UNASSIGNED

UNASSIGNED, OC3_PORT, OC12_PORT, OC48_PORT, ONE_GE_PORT, ESCON_PORT, DV6000_PORT, SDI_D1_VIDEO_PORT, HDTV_PORT, PASS_THRU_PORT, ETR_CLO_PORT, ISC compat, FC1G_PORT, FC2G_PORT, FICON1G_PORT, FICON2G_PORT, ISC peer

TXP-MR-2_5G.config.client.ppmSlotAssignment

UNASSIGNED

UNASSIGNED, PPM (1 Port)

TXP-MR-2_5G.config.client.SDBER

1.00E-07

1E-5, 1E-6, 1E-7, 1E-8, 1E-9

TXP-MR-2_5G.config.client.SFBER

1.00E-04

1E-3, 1E-4, 1E-5

TXP-MR-2_5G.config.client.TerminationMode

Transparent

Transparent, Section, Line when ppmPortAssignment is UNASSIGNED, OC3_PORT, OC12_PORT, OC48_PORT

Transparent when ppmPortAssignment is OC3_PORT, OC12_PORT, OC48_PORT, ONE_GE_PORT, ESCON_PORT, DV6000_PORT, SDI_D1_VIDEO_PORT, HDTV_PORT, PASS_THRU_PORT, ETR_CLO_PORT, ISC compat, FC1G_PORT, FC2G_PORT, FICON1G_PORT, FICON2G_PORT, ISC peer

TXP-MR-2_5G.config.trunk.AINSSoakTime

08:00 (hours:mins)

00:00, 00:15, 00:30 .. 48:00

TXP-MR-2_5G.config.trunk.AlsMode

Disabled

Disabled, Auto Restart, Manual Restart, Manual Restart for Test

TXP-MR-2_5G.config.trunk.AlsRecoveryPulseDuration

40.0 (seconds)

2.0, 2.1, 2.2 .. 100.0 when AlsMode is Disabled, Auto Restart, Manual Restart

80.0, 80.1, 80.2 .. 100.0 when AlsMode is Manual Restart for Test

TXP-MR-2_5G.config.trunk.AlsRecoveryPulseInterval

100 (seconds)

60-300

TXP-MR-2_5G.config.trunk.SDBER

1.00E-07

1E-5, 1E-6, 1E-7, 1E-8, 1E-9

TXP-MR-2_5G.config.trunk.SFBER

1.00E-04

1E-3, 1E-4, 1E-5

TXP-MR-2_5G.opticalthresholds.client.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.alarm.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.alarm.LowRxPower

-21.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.alarm.LowTxPower

-15.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.warning.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.warning.15min.HighRxPower

2.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.warning.15min.HighTxPower

2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.warning.15min.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.warning.15min.LowTxPower

-7.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.warning.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.warning.1day.HighRxPower

2.5 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.warning.1day.HighTxPower

2.5 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.warning.1day.LowRxPower

-20.5 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.warning.1day.LowTxPower

-7.5 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.trunk.alarm.HighLaserBias

98.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.trunk.alarm.HighRxPower

-8.0 (dBrn)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.trunk.alarm.LowRxPower

-25.0 (dBrn)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.trunk.warning.15min.HighLaserBias

95.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.trunk.warning.15min.HighRxPower

-7.5 (dBrn)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.trunk.warning.15min.LowRxPower

-24.5 (dBrn)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.trunk.warning.1day.HighLaserBias

96.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.trunk.warning.1day.HighRxPower

-7.3 (dBrn)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.trunk.warning.1day.LowRxPower

-24.7 (dBrn)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.otn.fecthresholds.1gethernet.15min.BitErrorsCorrected

112500 (count)

0-9033621811200

TXP-MR-2_5G.otn.fecthresholds.1gethernet.15min.UncorrectableWords

1 (count)

0-4724697600

TXP-MR-2_5G.otn.fecthresholds.1gethernet.1day.BitErrorsCorrected

10800000 (count)

0-867227693875200

TXP-MR-2_5G.otn.fecthresholds.1gethernet.1day.UncorrectableWords

96 (count)

0-453570969600

TXP-MR-2_5G.otn.fecthresholds.1gfiberchannel.15min.BitErrorsCorrected

90000 (count)

0-9033621811200

TXP-MR-2_5G.otn.fecthresholds.1gfiberchannel.15min.UncorrectableWords

1 (count)

0-4724697600

TXP-MR-2_5G.otn.fecthresholds.1gfiberchannel.1day.BitErrorsCorrected

8640000 (count)

0-867227693875200

TXP-MR-2_5G.otn.fecthresholds.1gfiberchannel.1day.UncorrectableWords

96 (count)

0-453570969600

TXP-MR-2_5G.otn.fecthresholds.1gficon.15min.BitErrorsCorrected

90000 (count)

0-9033621811200

TXP-MR-2_5G.otn.fecthresholds.1gficon.15min.UncorrectableWords

1 (count)

0-4724697600

TXP-MR-2_5G.otn.fecthresholds.1gficon.1day.BitErrorsCorrected

8640000 (count)

0-867227693875200

TXP-MR-2_5G.otn.fecthresholds.1gficon.1day.UncorrectableWords

96 (count)

0-453570969600

TXP-MR-2_5G.otn.fecthresholds.2gfiberchannel.15min.BitErrorsCorrected

180900 (count)

0-9033621811200

TXP-MR-2_5G.otn.fecthresholds.2gfiberchannel.15min.UncorrectableWords

1 (count)

0-4724697600

TXP-MR-2_5G.otn.fecthresholds.2gfiberchannel.1day.BitErrorsCorrected

17366400 (count)

0-867227693875200

TXP-MR-2_5G.otn.fecthresholds.2gfiberchannel.1day.UncorrectableWords

96 (count)

0-453570969600

TXP-MR-2_5G.otn.fecthresholds.2gficon.15min.BitErrorsCorrected

180900 (count)

0-9033621811200

TXP-MR-2_5G.otn.fecthresholds.2gficon.15min.UncorrectableWords

1 (count)

0-4724697600

TXP-MR-2_5G.otn.fecthresholds.2gficon.1day.BitErrorsCorrected

17366400 (count)

0-867227693875200

TXP-MR-2_5G.otn.fecthresholds.2gficon.1day.UncorrectableWords

96 (count)

0-453570969600

TXP-MR-2_5G.otn.fecthresholds.oc12.15min.BitErrorsCorrected

56457 (count)

0-9033621811200

TXP-MR-2_5G.otn.fecthresholds.oc12.15min.UncorrectableWords

1 (count)

0-4724697600

TXP-MR-2_5G.otn.fecthresholds.oc12.1day.BitErrorsCorrected

5419872 (count)

0-867227693875200

TXP-MR-2_5G.otn.fecthresholds.oc12.1day.UncorrectableWords

96 (count)

0-453570969600

TXP-MR-2_5G.otn.fecthresholds.oc3.15min.BitErrorsCorrected

15012 (count)

0-9033621811200

TXP-MR-2_5G.otn.fecthresholds.oc3.15min.UncorrectableWords

1 (count)

0-4724697600

TXP-MR-2_5G.otn.fecthresholds.oc3.1day.BitErrorsCorrected

1441152 (count)

0-867227693875200

TXP-MR-2_5G.otn.fecthresholds.oc3.1day.UncorrectableWords

96 (count)

0-453570969600

TXP-MR-2_5G.otn.fecthresholds.oc48.15min.BitErrorsCorrected

225837 (count)

0-9033621811200

TXP-MR-2_5G.otn.fecthresholds.oc48.15min.UncorrectableWords

1 (count)

0-4724697600

TXP-MR-2_5G.otn.fecthresholds.oc48.1day.BitErrorsCorrected

21680352 (count)

0-867227693875200

TXP-MR-2_5G.otn.fecthresholds.oc48.1day.UncorrectableWords

96 (count)

0-453570969600

TXP-MR-2_5G.otn.g709thresholds.pm.farend.15min.BBE

21260 (count)

0-8850600

TXP-MR-2_5G.otn.g709thresholds.pm.farend.15min.ES

87 (seconds)

0-900

TXP-MR-2_5G.otn.g709thresholds.pm.farend.15min.FC

10 (count)

0-72

TXP-MR-2_5G.otn.g709thresholds.pm.farend.15min.SES

1 (seconds)

0-900

TXP-MR-2_5G.otn.g709thresholds.pm.farend.15min.UAS

3 (seconds)

0-900

TXP-MR-2_5G.otn.g709thresholds.pm.farend.1day.BBE

212600 (count)

0-849657600

TXP-MR-2_5G.otn.g709thresholds.pm.farend.1day.ES

864 (seconds)

0-86400

TXP-MR-2_5G.otn.g709thresholds.pm.farend.1day.FC

40 (count)

0-6912

TXP-MR-2_5G.otn.g709thresholds.pm.farend.1day.SES

4 (seconds)

0-86400

TXP-MR-2_5G.otn.g709thresholds.pm.farend.1day.UAS

10 (seconds)

0-86400

TXP-MR-2_5G.otn.g709thresholds.pm.nearend.15min.BBE

21260 (count)

0-8850600

TXP-MR-2_5G.otn.g709thresholds.pm.nearend.15min.ES

87 (seconds)

0-900

TXP-MR-2_5G.otn.g709thresholds.pm.nearend.15min.FC

10 (count)

0-72

TXP-MR-2_5G.otn.g709thresholds.pm.nearend.15min.SES

1 (seconds)

0-900

TXP-MR-2_5G.otn.g709thresholds.pm.nearend.15min.UAS

3 (seconds)

0-900

TXP-MR-2_5G.otn.g709thresholds.pm.nearend.1day.BBE

212600 (count)

0-849657600

TXP-MR-2_5G.otn.g709thresholds.pm.nearend.1day.ES

864 (seconds)

0-86400

TXP-MR-2_5G.otn.g709thresholds.pm.nearend.1day.FC

40 (count)

0-6912

TXP-MR-2_5G.otn.g709thresholds.pm.nearend.1day.SES

4 (seconds)

0-86400

TXP-MR-2_5G.otn.g709thresholds.pm.nearend.1day.UAS

10 (seconds)

0-86400

TXP-MR-2_5G.otn.g709thresholds.sm.farend.15min.BBE

10000 (count)

0-8850600

TXP-MR-2_5G.otn.g709thresholds.sm.farend.15min.ES

500 (seconds)

0-900

TXP-MR-2_5G.otn.g709thresholds.sm.farend.15min.FC

10 (count)

0-72

TXP-MR-2_5G.otn.g709thresholds.sm.farend.15min.SES

500 (seconds)

0-900

TXP-MR-2_5G.otn.g709thresholds.sm.farend.15min.UAS

500 (seconds)

0-900

TXP-MR-2_5G.otn.g709thresholds.sm.farend.1day.BBE

100000 (count)

0-849657600

TXP-MR-2_5G.otn.g709thresholds.sm.farend.1day.ES

5000 (seconds)

0-86400

TXP-MR-2_5G.otn.g709thresholds.sm.farend.1day.FC

40 (count)

0-6912

TXP-MR-2_5G.otn.g709thresholds.sm.farend.1day.SES

5000 (seconds)

0-86400

TXP-MR-2_5G.otn.g709thresholds.sm.farend.1day.UAS

5000 (seconds)

0-86400

TXP-MR-2_5G.otn.g709thresholds.sm.nearend.15min.BBE

10000 (count)

0-8850600

TXP-MR-2_5G.otn.g709thresholds.sm.nearend.15min.ES

500 (seconds)

0-900

TXP-MR-2_5G.otn.g709thresholds.sm.nearend.15min.FC

10 (count)

0-72

TXP-MR-2_5G.otn.g709thresholds.sm.nearend.15min.SES

500 (seconds)

0-900

TXP-MR-2_5G.otn.g709thresholds.sm.nearend.15min.UAS

500 (seconds)

0-900

TXP-MR-2_5G.otn.g709thresholds.sm.nearend.1day.BBE

100000 (count)

0-849657600

TXP-MR-2_5G.otn.g709thresholds.sm.nearend.1day.ES

5000 (seconds)

0-86400

TXP-MR-2_5G.otn.g709thresholds.sm.nearend.1day.FC

40 (count)

0-6912

TXP-MR-2_5G.otn.g709thresholds.sm.nearend.1day.SES

5000 (seconds)

0-86400

TXP-MR-2_5G.otn.g709thresholds.sm.nearend.1day.UAS

5000 (seconds)

0-86400

TXP-MR-2_5G.otn.otnLines.FEC

Enable

Disable, Enable when G709OTN is Enable

Disable when G709OTN is Disable

TXP-MR-2_5G.otn.otnLines.G709OTN

Enable

Disable, Enable

TXP-MR-2_5G.otn.otnLines.SDBER

1.00E-07

1E-5, 1E-6, 1E-7, 1E-8, 1E-9

TXP-MR-2_5G.pmthresholds.oc12.line.farend.15min.CV

5315 (B2 count)

0-552600

TXP-MR-2_5G.pmthresholds.oc12.line.farend.15min.ES

87 (seconds)

0-900

TXP-MR-2_5G.pmthresholds.oc12.line.farend.15min.FC

10 (count)

0-72

TXP-MR-2_5G.pmthresholds.oc12.line.farend.15min.SES

1 (seconds)

0-900

TXP-MR-2_5G.pmthresholds.oc12.line.farend.15min.UAS

3 (seconds)

0-900

TXP-MR-2_5G.pmthresholds.oc12.line.farend.1day.CV

53150 (B2 count)

0-53049600

TXP-MR-2_5G.pmthresholds.oc12.line.farend.1day.ES

864 (seconds)

0-86400

TXP-MR-2_5G.pmthresholds.oc12.line.farend.1day.FC

40 (count)

0-72

TXP-MR-2_5G.pmthresholds.oc12.line.farend.1day.SES

4 (seconds)

0-86400

TXP-MR-2_5G.pmthresholds.oc12.line.farend.1day.UAS

10 (seconds)

0-86400

TXP-MR-2_5G.pmthresholds.oc12.line.nearend.15min.CV

5315 (B2 count)

0-552600

TXP-MR-2_5G.pmthresholds.oc12.line.nearend.15min.ES

87 (seconds)

0-900

TXP-MR-2_5G.pmthresholds.oc12.line.nearend.15min.FC

10 (count)

0-72

TXP-MR-2_5G.pmthresholds.oc12.line.nearend.15min.SES

1 (seconds)

0-900

TXP-MR-2_5G.pmthresholds.oc12.line.nearend.15min.UAS

3 (seconds)

0-900

TXP-MR-2_5G.pmthresholds.oc12.line.nearend.1day.CV

53150 (B2 count)

0-53049600

TXP-MR-2_5G.pmthresholds.oc12.line.nearend.1day.ES

864 (seconds)

0-86400

TXP-MR-2_5G.pmthresholds.oc12.line.nearend.1day.FC

40 (count)

0-6912

TXP-MR-2_5G.pmthresholds.oc12.line.nearend.1day.SES

4 (seconds)

0-86400

TXP-MR-2_5G.pmthresholds.oc12.line.nearend.1day.UAS

10 (seconds)

0-86400

TXP-MR-2_5G.pmthresholds.oc12.section.nearend.15min.CV

10000 (B1 count)

0-553500

TXP-MR-2_5G.pmthresholds.oc12.section.nearend.15min.ES

500 (seconds)

0-900

TXP-MR-2_5G.pmthresholds.oc12.section.nearend.15min.SEFS

500 (seconds)

0-900

TXP-MR-2_5G.pmthresholds.oc12.section.nearend.15min.SES

500 (seconds)

0-900

TXP-MR-2_5G.pmthresholds.oc12.section.nearend.1day.CV

100000 (B1 count)

0-53136000

TXP-MR-2_5G.pmthresholds.oc12.section.nearend.1day.ES

5000 (seconds)

0-86400

TXP-MR-2_5G.pmthresholds.oc12.section.nearend.1day.SEFS

5000 (seconds)

0-86400

TXP-MR-2_5G.pmthresholds.oc12.section.nearend.1day.SES

5000 (seconds)

0-86400

TXP-MR-2_5G.pmthresholds.oc3.line.farend.15min.CV

1312 (B2 count)

0-137700

TXP-MR-2_5G.pmthresholds.oc3.line.farend.15min.ES

87 (seconds)

0-900

TXP-MR-2_5G.pmthresholds.oc3.line.farend.15min.FC

10 (count)

0-72

TXP-MR-2_5G.pmthresholds.oc3.line.farend.15min.SES

1 (seconds)

0-900

TXP-MR-2_5G.pmthresholds.oc3.line.farend.15min.UAS

3 (seconds)

0-900

TXP-MR-2_5G.pmthresholds.oc3.line.farend.1day.CV

13120 (B2 count)

0-13219200

TXP-MR-2_5G.pmthresholds.oc3.line.farend.1day.ES

864 (seconds)

0-86400

TXP-MR-2_5G.pmthresholds.oc3.line.farend.1day.FC

40 (count)

0-6912

TXP-MR-2_5G.pmthresholds.oc3.line.farend.1day.SES

4 (seconds)

0-86400

TXP-MR-2_5G.pmthresholds.oc3.line.farend.1day.UAS

10 (seconds)

0-86400

TXP-MR-2_5G.pmthresholds.oc3.line.nearend.15min.CV

1312 (B2 count)

0-137700

TXP-MR-2_5G.pmthresholds.oc3.line.nearend.15min.ES

87 (seconds)

0-900

TXP-MR-2_5G.pmthresholds.oc3.line.nearend.15min.FC

10 (count)

0-72

TXP-MR-2_5G.pmthresholds.oc3.line.nearend.15min.SES

1 (seconds)

0-900

TXP-MR-2_5G.pmthresholds.oc3.line.nearend.15min.UAS

3 (seconds)

0-900

TXP-MR-2_5G.pmthresholds.oc3.line.nearend.1day.CV

13120 (B2 count)

0-13219200

TXP-MR-2_5G.pmthresholds.oc3.line.nearend.1day.ES

864 (seconds)

0-86400

TXP-MR-2_5G.pmthresholds.oc3.line.nearend.1day.FC

40 (count)

0-6912

TXP-MR-2_5G.pmthresholds.oc3.line.nearend.1day.SES

4 (seconds)

0-86400

TXP-MR-2_5G.pmthresholds.oc3.line.nearend.1day.UAS

10 (seconds)

0-86400

TXP-MR-2_5G.pmthresholds.oc3.section.nearend.15min.CV

10000 (B1 count)

0-138600

TXP-MR-2_5G.pmthresholds.oc3.section.nearend.15min.ES

500 (seconds)

0-900

TXP-MR-2_5G.pmthresholds.oc3.section.nearend.15min.SEFS

500 (seconds)

0-900

TXP-MR-2_5G.pmthresholds.oc3.section.nearend.15min.SES

500 (seconds)

0-900

TXP-MR-2_5G.pmthresholds.oc3.section.nearend.1day.CV

100000 (B1 count)

0-13305600

TXP-MR-2_5G.pmthresholds.oc3.section.nearend.1day.ES

5000 (seconds)

0-86400

TXP-MR-2_5G.pmthresholds.oc3.section.nearend.1day.SEFS

5000 (seconds)

0-86400

TXP-MR-2_5G.pmthresholds.oc3.section.nearend.1day.SES

5000 (seconds)

0-86400

TXP-MR-2_5G.pmthresholds.oc48.line.farend.15min.CV

21260 (B2 count)

0-2212200

TXP-MR-2_5G.pmthresholds.oc48.line.farend.15min.ES

87 (seconds)

0-900

TXP-MR-2_5G.pmthresholds.oc48.line.farend.15min.FC

10 (count)

0-72

TXP-MR-2_5G.pmthresholds.oc48.line.farend.15min.SES

1 (seconds)

0-900

TXP-MR-2_5G.pmthresholds.oc48.line.farend.15min.UAS

3 (seconds)

0-900

TXP-MR-2_5G.pmthresholds.oc48.line.farend.1day.CV

212600 (B2 count)

0-212371200

TXP-MR-2_5G.pmthresholds.oc48.line.farend.1day.ES

864 (seconds)

0-86400

TXP-MR-2_5G.pmthresholds.oc48.line.farend.1day.FC

40 (count)

0-6912

TXP-MR-2_5G.pmthresholds.oc48.line.farend.1day.SES

4 (seconds)

0-86400

TXP-MR-2_5G.pmthresholds.oc48.line.farend.1day.UAS

10 (seconds)

0-86400

TXP-MR-2_5G.pmthresholds.oc48.line.nearend.15min.CV

21260 (B2 count)

0-2212200

TXP-MR-2_5G.pmthresholds.oc48.line.nearend.15min.ES

87 (seconds)

0-900

TXP-MR-2_5G.pmthresholds.oc48.line.nearend.15min.FC

10 (count)

0-72

TXP-MR-2_5G.pmthresholds.oc48.line.nearend.15min.SES

1 (seconds)

0-900

TXP-MR-2_5G.pmthresholds.oc48.line.nearend.15min.UAS

3 (seconds)

0-900

TXP-MR-2_5G.pmthresholds.oc48.line.nearend.1day.CV

212600 (B2 count)

0-212371200

TXP-MR-2_5G.pmthresholds.oc48.line.nearend.1day.ES

864 (seconds)

0-86400

TXP-MR-2_5G.pmthresholds.oc48.line.nearend.1day.FC

40 (count)

0-6912

TXP-MR-2_5G.pmthresholds.oc48.line.nearend.1day.SES

4 (seconds)

0-86400

TXP-MR-2_5G.pmthresholds.oc48.line.nearend.1day.UAS

10 (seconds)

0-86400

TXP-MR-2_5G.pmthresholds.oc48.section.nearend.15min.CV

10000 (B1 count)

0-2151900

TXP-MR-2_5G.pmthresholds.oc48.section.nearend.15min.ES

500 (seconds)

0-900

TXP-MR-2_5G.pmthresholds.oc48.section.nearend.15min.SEFS

500 (seconds)

0-900

TXP-MR-2_5G.pmthresholds.oc48.section.nearend.15min.SES

500 (seconds)

0-900

TXP-MR-2_5G.pmthresholds.oc48.section.nearend.1day.CV

100000 (B1 count)

0-206582400

TXP-MR-2_5G.pmthresholds.oc48.section.nearend.1day.ES

5000 (seconds)

0-86400

TXP-MR-2_5G.pmthresholds.oc48.section.nearend.1day.SEFS

5000 (seconds)

0-86400

TXP-MR-2_5G.pmthresholds.oc48.section.nearend.1day.SES

5000 (seconds)

0-86400


D.2.1.8  TXPP_MR_2.5G Card Default Settings

Table D-8 lists the TXPP_MR_2.5G card default settings.

Table D-8 TXPP_MR_2.5G Card Default Settings (ANSI) 

Default Name
Default Value
Default Domain

TXPP-MR-2_5G.config.client.AINSSoakTime

08:00 (hours:mins)

00:00, 00:15, 00:30 .. 48:00

TXPP-MR-2_5G.config.client.AlsMode

Disabled

Disabled, Auto Restart, Manual Restart, Manual Restart for Test

TXPP-MR-2_5G.config.client.AlsRecoveryPulseDuration

40.0 (seconds)

2.0, 2.1, 2.2 .. 100.0 when AlsMode is Disabled, Auto Restart, Manual Restart

80.0, 80.1, 80.2 .. 100.0 when AlsMode is Manual Restart for Test

TXPP-MR-2_5G.config.client.AlsRecoveryPulseInterval

100 (seconds)

60-300

TXPP-MR-2_5G.config.client.ppmPortAssignment

UNASSIGNED

UNASSIGNED, OC3_PORT, OC12_PORT, OC48_PORT, ONE_GE_PORT, ESCON_PORT, DV6000_PORT, SDI_D1_VIDEO_PORT, HDTV_PORT, PASS_THRU_PORT, ETR_CLO_PORT, ISC compat, FC1G_PORT, FC2G_PORT, FICON1G_PORT, FICON2G_PORT, ISC peer

TXPP-MR-2_5G.config.client.ppmSlotAssignment

UNASSIGNED

UNASSIGNED, PPM (1 Port)

TXPP-MR-2_5G.config.client.SDBER

1.00E-07

1E-5, 1E-6, 1E-7, 1E-8, 1E-9

TXPP-MR-2_5G.config.client.SFBER

1.00E-04

1E-3, 1E-4, 1E-5

TXPP-MR-2_5G.config.client.TerminationMode

Transparent

Transparent, Section, Line when ppmPortAssignment is UNASSIGNED, OC3_PORT, OC12_PORT, OC48_PORT

Transparent when ppmPortAssignment is OC3_PORT, OC12_PORT, OC48_PORT, ONE_GE_PORT, ESCON_PORT, DV6000_PORT, SDI_D1_VIDEO_PORT, HDTV_PORT, PASS_THRU_PORT, ETR_CLO_PORT, ISC compat, FC1G_PORT, FC2G_PORT, FICON1G_PORT, FICON2G_PORT, ISC peer

TXPP-MR-2_5G.config.trunk.AINSSoakTime

08:00 (hours:mins)

00:00, 00:15, 00:30 .. 48:00

TXPP-MR-2_5G.config.trunk.AlsMode

Disabled

Disabled, Auto Restart, Manual Restart, Manual Restart for Test

TXPP-MR-2_5G.config.trunk.AlsRecoveryPulseDuration

40.0 (seconds)

2.0, 2.1, 2.2 .. 100.0 when AlsMode is Disabled, Auto Restart, Manual Restart

80.0, 80.1, 80.2 .. 100.0 when AlsMode is Manual Restart for Test

TXPP-MR-2_5G.config.trunk.AlsRecoveryPulseInterval

100 (seconds)

60-300

TXPP-MR-2_5G.config.trunk.SDBER

1.00E-07

1E-5, 1E-6, 1E-7, 1E-8, 1E-9

TXPP-MR-2_5G.config.trunk.SFBER

1.00E-04

1E-3, 1E-4, 1E-5

TXPP-MR-2_5G.opticalthresholds.client.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.alarm.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.alarm.LowRxPower

-21.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.alarm.LowTxPower

-15.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.warning.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.warning.15min.HighRxPower

2.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.warning.15min.HighTxPower

2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.warning.15min.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.warning.15min.LowTxPower

-7.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.warning.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.warning.1day.HighRxPower

2.5 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.warning.1day.HighTxPower

2.5 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.warning.1day.LowRxPower

-20.5 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.warning.1day.LowTxPower

-7.5 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.trunk.alarm.HighLaserBias

98.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.trunk.alarm.HighRxPower

-8.0 (dBrn)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.trunk.alarm.LowRxPower

-25.0 (dBrn)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.trunk.warning.15min.HighLaserBias

95.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.trunk.warning.15min.HighRxPower

-7.5 (dBrn)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.trunk.warning.15min.LowRxPower

-24.5 (dBrn)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.trunk.warning.1day.HighLaserBias

96.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.trunk.warning.1day.HighRxPower

-7.3 (dBrn)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.trunk.warning.1day.LowRxPower

-24.7 (dBrn)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.otn.fecthresholds.1gethernet.15min.BitErrorsCorrected

112500 (count)

0-9033621811200

TXPP-MR-2_5G.otn.fecthresholds.1gethernet.15min.UncorrectableWords

1 (count)

0-4724697600

TXPP-MR-2_5G.otn.fecthresholds.1gethernet.1day.BitErrorsCorrected

10800000 (count)

0-867227693875200

TXPP-MR-2_5G.otn.fecthresholds.1gethernet.1day.UncorrectableWords

96 (count)

0-453570969600

TXPP-MR-2_5G.otn.fecthresholds.1gfiberchannel.15min.BitErrorsCorrected

90000 (count)

0-9033621811200

TXPP-MR-2_5G.otn.fecthresholds.1gfiberchannel.15min.UncorrectableWords

1 (count)

0-4724697600

TXPP-MR-2_5G.otn.fecthresholds.1gfiberchannel.1day.BitErrorsCorrected

8640000 (count)

0-867227693875200

TXPP-MR-2_5G.otn.fecthresholds.1gfiberchannel.1day.UncorrectableWords

96 (count)

0-453570969600

TXPP-MR-2_5G.otn.fecthresholds.1gficon.15min.BitErrorsCorrected

90000 (count)

0-9033621811200

TXPP-MR-2_5G.otn.fecthresholds.1gficon.15min.UncorrectableWords

1 (count)

0-4724697600

TXPP-MR-2_5G.otn.fecthresholds.1gficon.1day.BitErrorsCorrected

8640000 (count)

0-867227693875200

TXPP-MR-2_5G.otn.fecthresholds.1gficon.1day.UncorrectableWords

96 (count)

0-453570969600

TXPP-MR-2_5G.otn.fecthresholds.2gfiberchannel.15min.BitErrorsCorrected

180900 (count)

0-9033621811200

TXPP-MR-2_5G.otn.fecthresholds.2gfiberchannel.15min.UncorrectableWords

1 (count)

0-4724697600

TXPP-MR-2_5G.otn.fecthresholds.2gfiberchannel.1day.BitErrorsCorrected

17366400 (count)

0-867227693875200

TXPP-MR-2_5G.otn.fecthresholds.2gfiberchannel.1day.UncorrectableWords

96 (count)

0-453570969600

TXPP-MR-2_5G.otn.fecthresholds.2gficon.15min.BitErrorsCorrected

180900 (count)

0-9033621811200

TXPP-MR-2_5G.otn.fecthresholds.2gficon.15min.UncorrectableWords

1 (count)

0-4724697600

TXPP-MR-2_5G.otn.fecthresholds.2gficon.1day.BitErrorsCorrected

17366400 (count)

0-867227693875200

TXPP-MR-2_5G.otn.fecthresholds.2gficon.1day.UncorrectableWords

96 (count)

0-453570969600

TXPP-MR-2_5G.otn.fecthresholds.oc12.15min.BitErrorsCorrected

56457 (count)

0-9033621811200

TXPP-MR-2_5G.otn.fecthresholds.oc12.15min.UncorrectableWords

1 (count)

0-4724697600

TXPP-MR-2_5G.otn.fecthresholds.oc12.1day.BitErrorsCorrected

5419872 (count)

0-867227693875200

TXPP-MR-2_5G.otn.fecthresholds.oc12.1day.UncorrectableWords

96 (count)

0-453570969600

TXPP-MR-2_5G.otn.fecthresholds.oc3.15min.BitErrorsCorrected

15012 (count)

0-9033621811200

TXPP-MR-2_5G.otn.fecthresholds.oc3.15min.UncorrectableWords

1 (count)

0-4724697600

TXPP-MR-2_5G.otn.fecthresholds.oc3.1day.BitErrorsCorrected

1441152 (count)

0-867227693875200

TXPP-MR-2_5G.otn.fecthresholds.oc3.1day.UncorrectableWords

96 (count)

0-453570969600

TXPP-MR-2_5G.otn.fecthresholds.oc48.15min.BitErrorsCorrected

225837 (count)

0-9033621811200

TXPP-MR-2_5G.otn.fecthresholds.oc48.15min.UncorrectableWords

1 (count)

0-4724697600

TXPP-MR-2_5G.otn.fecthresholds.oc48.1day.BitErrorsCorrected

21680352 (count)

0-867227693875200

TXPP-MR-2_5G.otn.fecthresholds.oc48.1day.UncorrectableWords

96 (count)

0-453570969600

TXPP-MR-2_5G.otn.g709thresholds.pm.farend.15min.BBE

21260 (count)

0-8850600

TXPP-MR-2_5G.otn.g709thresholds.pm.farend.15min.ES

87 (seconds)

0-900

TXPP-MR-2_5G.otn.g709thresholds.pm.farend.15min.FC

10 (count)

0-72

TXPP-MR-2_5G.otn.g709thresholds.pm.farend.15min.SES

1 (seconds)

0-900

TXPP-MR-2_5G.otn.g709thresholds.pm.farend.15min.UAS

3 (seconds)

0-900

TXPP-MR-2_5G.otn.g709thresholds.pm.farend.1day.BBE

212600 (count)

0-849657600

TXPP-MR-2_5G.otn.g709thresholds.pm.farend.1day.ES

864 (seconds)

0-86400

TXPP-MR-2_5G.otn.g709thresholds.pm.farend.1day.FC

40 (count)

0-6912

TXPP-MR-2_5G.otn.g709thresholds.pm.farend.1day.SES

4 (seconds)

0-86400

TXPP-MR-2_5G.otn.g709thresholds.pm.farend.1day.UAS

10 (seconds)

0-86400

TXPP-MR-2_5G.otn.g709thresholds.pm.nearend.15min.BBE

21260 (count)

0-8850600

TXPP-MR-2_5G.otn.g709thresholds.pm.nearend.15min.ES

87 (seconds)

0-900

TXPP-MR-2_5G.otn.g709thresholds.pm.nearend.15min.FC

10 (count)

0-72

TXPP-MR-2_5G.otn.g709thresholds.pm.nearend.15min.SES

1 (seconds)

0-900

TXPP-MR-2_5G.otn.g709thresholds.pm.nearend.15min.UAS

3 (seconds)

0-900

TXPP-MR-2_5G.otn.g709thresholds.pm.nearend.1day.BBE

212600 (count)

0-849657600

TXPP-MR-2_5G.otn.g709thresholds.pm.nearend.1day.ES

864 (seconds)

0-86400

TXPP-MR-2_5G.otn.g709thresholds.pm.nearend.1day.FC

40 (count)

0-6912

TXPP-MR-2_5G.otn.g709thresholds.pm.nearend.1day.SES

4 (seconds)

0-86400

TXPP-MR-2_5G.otn.g709thresholds.pm.nearend.1day.UAS

10 (seconds)

0-86400

TXPP-MR-2_5G.otn.g709thresholds.sm.farend.15min.BBE

10000 (count)

0-8850600

TXPP-MR-2_5G.otn.g709thresholds.sm.farend.15min.ES

500 (seconds)

0-900

TXPP-MR-2_5G.otn.g709thresholds.sm.farend.15min.FC

10 (count)

0-72

TXPP-MR-2_5G.otn.g709thresholds.sm.farend.15min.SES

500 (seconds)

0-900

TXPP-MR-2_5G.otn.g709thresholds.sm.farend.15min.UAS

500 (seconds)

0-900

TXPP-MR-2_5G.otn.g709thresholds.sm.farend.1day.BBE

100000 (count)

0-849657600

TXPP-MR-2_5G.otn.g709thresholds.sm.farend.1day.ES

5000 (seconds)

0-86400

TXPP-MR-2_5G.otn.g709thresholds.sm.farend.1day.FC

40 (count)

0-6912

TXPP-MR-2_5G.otn.g709thresholds.sm.farend.1day.SES

5000 (seconds)

0-86400

TXPP-MR-2_5G.otn.g709thresholds.sm.farend.1day.UAS

5000 (seconds)

0-86400

TXPP-MR-2_5G.otn.g709thresholds.sm.nearend.15min.BBE

10000 (count)

0-8850600

TXPP-MR-2_5G.otn.g709thresholds.sm.nearend.15min.ES

500 (seconds)

0-900

TXPP-MR-2_5G.otn.g709thresholds.sm.nearend.15min.FC

10 (count)

0-72

TXPP-MR-2_5G.otn.g709thresholds.sm.nearend.15min.SES

500 (seconds)

0-900

TXPP-MR-2_5G.otn.g709thresholds.sm.nearend.15min.UAS

500 (seconds)

0-900

TXPP-MR-2_5G.otn.g709thresholds.sm.nearend.1day.BBE

100000 (count)

0-849657600

TXPP-MR-2_5G.otn.g709thresholds.sm.nearend.1day.ES

5000 (seconds)

0-86400

TXPP-MR-2_5G.otn.g709thresholds.sm.nearend.1day.FC

40 (count)

0-6912

TXPP-MR-2_5G.otn.g709thresholds.sm.nearend.1day.SES

5000 (seconds)

0-86400

TXPP-MR-2_5G.otn.g709thresholds.sm.nearend.1day.UAS

5000 (seconds)

0-86400

TXPP-MR-2_5G.otn.otnLines.FEC

Enable

Disable, Enable when G709OTN is Enable

Disable when G709OTN is Disable

TXPP-MR-2_5G.otn.otnLines.G709OTN

Enable

Disable, Enable

TXPP-MR-2_5G.otn.otnLines.SDBER

1.00E-07

1E-5, 1E-6, 1E-7, 1E-8, 1E-9

TXPP-MR-2_5G.pmthresholds.oc12.line.farend.15min.CV

5315 (B2 count)

0-552600

TXPP-MR-2_5G.pmthresholds.oc12.line.farend.15min.ES

87 (seconds)

0-900

TXPP-MR-2_5G.pmthresholds.oc12.line.farend.15min.FC

10 (count)

0-72

TXPP-MR-2_5G.pmthresholds.oc12.line.farend.15min.SES

1 (seconds)

0-900

TXPP-MR-2_5G.pmthresholds.oc12.line.farend.15min.UAS

3 (seconds)

0-900

TXPP-MR-2_5G.pmthresholds.oc12.line.farend.1day.CV

53150 (B2 count)

0-53049600

TXPP-MR-2_5G.pmthresholds.oc12.line.farend.1day.ES

864 (seconds)

0-86400

TXPP-MR-2_5G.pmthresholds.oc12.line.farend.1day.FC

40 (count)

0-72

TXPP-MR-2_5G.pmthresholds.oc12.line.farend.1day.SES

4 (seconds)

0-86400

TXPP-MR-2_5G.pmthresholds.oc12.line.farend.1day.UAS

10 (seconds)

0-86400

TXPP-MR-2_5G.pmthresholds.oc12.line.nearend.15min.CV

5315 (B2 count)

0-552600

TXPP-MR-2_5G.pmthresholds.oc12.line.nearend.15min.ES

87 (seconds)

0-900

TXPP-MR-2_5G.pmthresholds.oc12.line.nearend.15min.FC

10 (count)

0-72

TXPP-MR-2_5G.pmthresholds.oc12.line.nearend.15min.SES

1 (seconds)

0-900

TXPP-MR-2_5G.pmthresholds.oc12.line.nearend.15min.UAS

3 (seconds)

0-900

TXPP-MR-2_5G.pmthresholds.oc12.line.nearend.1day.CV

53150 (B2 count)

0-53049600

TXPP-MR-2_5G.pmthresholds.oc12.line.nearend.1day.ES

864 (seconds)

0-86400

TXPP-MR-2_5G.pmthresholds.oc12.line.nearend.1day.FC

40 (count)

0-6912

TXPP-MR-2_5G.pmthresholds.oc12.line.nearend.1day.SES

4 (seconds)

0-86400

TXPP-MR-2_5G.pmthresholds.oc12.line.nearend.1day.UAS

10 (seconds)

0-86400

TXPP-MR-2_5G.pmthresholds.oc12.section.nearend.15min.CV

10000 (B1 count)

0-553500

TXPP-MR-2_5G.pmthresholds.oc12.section.nearend.15min.ES

500 (seconds)

0-900

TXPP-MR-2_5G.pmthresholds.oc12.section.nearend.15min.SEFS

500 (seconds)

0-900

TXPP-MR-2_5G.pmthresholds.oc12.section.nearend.15min.SES

500 (seconds)

0-900

TXPP-MR-2_5G.pmthresholds.oc12.section.nearend.1day.CV

100000 (B1 count)

0-53136000

TXPP-MR-2_5G.pmthresholds.oc12.section.nearend.1day.ES

5000 (seconds)

0-86400

TXPP-MR-2_5G.pmthresholds.oc12.section.nearend.1day.SEFS

5000 (seconds)

0-86400

TXPP-MR-2_5G.pmthresholds.oc12.section.nearend.1day.SES

5000 (seconds)

0-86400

TXPP-MR-2_5G.pmthresholds.oc3.line.farend.15min.CV

1312 (B2 count)

0-137700

TXPP-MR-2_5G.pmthresholds.oc3.line.farend.15min.ES

87 (seconds)

0-900

TXPP-MR-2_5G.pmthresholds.oc3.line.farend.15min.FC

10 (count)

0-72

TXPP-MR-2_5G.pmthresholds.oc3.line.farend.15min.SES

1 (seconds)

0-900

TXPP-MR-2_5G.pmthresholds.oc3.line.farend.15min.UAS

3 (seconds)

0-900

TXPP-MR-2_5G.pmthresholds.oc3.line.farend.1day.CV

13120 (B2 count)

0-13219200

TXPP-MR-2_5G.pmthresholds.oc3.line.farend.1day.ES

864 (seconds)

0-86400

TXPP-MR-2_5G.pmthresholds.oc3.line.farend.1day.FC

40 (count)

0-6912

TXPP-MR-2_5G.pmthresholds.oc3.line.farend.1day.SES

4 (seconds)

0-86400

TXPP-MR-2_5G.pmthresholds.oc3.line.farend.1day.UAS

10 (seconds)

0-86400

TXPP-MR-2_5G.pmthresholds.oc3.line.nearend.15min.CV

1312 (B2 count)

0-137700

TXPP-MR-2_5G.pmthresholds.oc3.line.nearend.15min.ES

87 (seconds)

0-900

TXPP-MR-2_5G.pmthresholds.oc3.line.nearend.15min.FC

10 (count)

0-72

TXPP-MR-2_5G.pmthresholds.oc3.line.nearend.15min.SES

1 (seconds)

0-900

TXPP-MR-2_5G.pmthresholds.oc3.line.nearend.15min.UAS

3 (seconds)

0-900

TXPP-MR-2_5G.pmthresholds.oc3.line.nearend.1day.CV

13120 (B2 count)

0-13219200

TXPP-MR-2_5G.pmthresholds.oc3.line.nearend.1day.ES

864 (seconds)

0-86400

TXPP-MR-2_5G.pmthresholds.oc3.line.nearend.1day.FC

40 (count)

0-6912

TXPP-MR-2_5G.pmthresholds.oc3.line.nearend.1day.SES

4 (seconds)

0-86400

TXPP-MR-2_5G.pmthresholds.oc3.line.nearend.1day.UAS

10 (seconds)

0-86400

TXPP-MR-2_5G.pmthresholds.oc3.section.nearend.15min.CV

10000 (B1 count)

0-138600

TXPP-MR-2_5G.pmthresholds.oc3.section.nearend.15min.ES

500 (seconds)

0-900

TXPP-MR-2_5G.pmthresholds.oc3.section.nearend.15min.SEFS

500 (seconds)

0-900

TXPP-MR-2_5G.pmthresholds.oc3.section.nearend.15min.SES

500 (seconds)

0-900

TXPP-MR-2_5G.pmthresholds.oc3.section.nearend.1day.CV

100000 (B1 count)

0-13305600

TXPP-MR-2_5G.pmthresholds.oc3.section.nearend.1day.ES

5000 (seconds)

0-86400

TXPP-MR-2_5G.pmthresholds.oc3.section.nearend.1day.SEFS

5000 (seconds)

0-86400

TXPP-MR-2_5G.pmthresholds.oc3.section.nearend.1day.SES

5000 (seconds)

0-86400

TXPP-MR-2_5G.pmthresholds.oc48.line.farend.15min.CV

21260 (B2 count)

0-2212200

TXPP-MR-2_5G.pmthresholds.oc48.line.farend.15min.ES

87 (seconds)

0-900

TXPP-MR-2_5G.pmthresholds.oc48.line.farend.15min.FC

10 (count)

0-72

TXPP-MR-2_5G.pmthresholds.oc48.line.farend.15min.SES

1 (seconds)

0-900

TXPP-MR-2_5G.pmthresholds.oc48.line.farend.15min.UAS

3 (seconds)

0-900

TXPP-MR-2_5G.pmthresholds.oc48.line.farend.1day.CV

212600 (B2 count)

0-212371200

TXPP-MR-2_5G.pmthresholds.oc48.line.farend.1day.ES

864 (seconds)

0-86400

TXPP-MR-2_5G.pmthresholds.oc48.line.farend.1day.FC

40 (count)

0-6912

TXPP-MR-2_5G.pmthresholds.oc48.line.farend.1day.SES

4 (seconds)

0-86400

TXPP-MR-2_5G.pmthresholds.oc48.line.farend.1day.UAS

10 (seconds)

0-86400

TXPP-MR-2_5G.pmthresholds.oc48.line.nearend.15min.CV

21260 (B2 count)

0-2212200

TXPP-MR-2_5G.pmthresholds.oc48.line.nearend.15min.ES

87 (seconds)

0-900

TXPP-MR-2_5G.pmthresholds.oc48.line.nearend.15min.FC

10 (count)

0-72

TXPP-MR-2_5G.pmthresholds.oc48.line.nearend.15min.SES

1 (seconds)

0-900

TXPP-MR-2_5G.pmthresholds.oc48.line.nearend.15min.UAS

3 (seconds)

0-900

TXPP-MR-2_5G.pmthresholds.oc48.line.nearend.1day.CV

212600 (B2 count)

0-212371200

TXPP-MR-2_5G.pmthresholds.oc48.line.nearend.1day.ES

864 (seconds)

0-86400

TXPP-MR-2_5G.pmthresholds.oc48.line.nearend.1day.FC

40 (count)

0-6912

TXPP-MR-2_5G.pmthresholds.oc48.line.nearend.1day.SES

4 (seconds)

0-86400

TXPP-MR-2_5G.pmthresholds.oc48.line.nearend.1day.UAS

10 (seconds)

0-86400

TXPP-MR-2_5G.pmthresholds.oc48.section.nearend.15min.CV

10000 (B1 count)

0-2151900

TXPP-MR-2_5G.pmthresholds.oc48.section.nearend.15min.ES

500 (seconds)

0-900

TXPP-MR-2_5G.pmthresholds.oc48.section.nearend.15min.SEFS

500 (seconds)

0-900

TXPP-MR-2_5G.pmthresholds.oc48.section.nearend.15min.SES

500 (seconds)

0-900

TXPP-MR-2_5G.pmthresholds.oc48.section.nearend.1day.CV

100000 (B1 count)

0-206582400

TXPP-MR-2_5G.pmthresholds.oc48.section.nearend.1day.ES

5000 (seconds)

0-86400

TXPP-MR-2_5G.pmthresholds.oc48.section.nearend.1day.SEFS

5000 (seconds)

0-86400

TXPP-MR-2_5G.pmthresholds.oc48.section.nearend.1day.SES

5000 (seconds)

0-86400


D.2.1.9  OSCM Card Default Settings

Table D-9 lists the OSCM card default settings.

Table D-9 OSCM Card Default Settings (ANSI) 

Default Name
Default Value
Default Domain

OSCM.pmthresholds.line.farend.15min.CV

1312 (B2 count)

0-137700

OSCM.pmthresholds.line.farend.15min.ES

87 (seconds)

0-900

OSCM.pmthresholds.line.farend.15min.FC

10 (count)

0-72

OSCM.pmthresholds.line.farend.15min.SES

1 (seconds)

0-900

OSCM.pmthresholds.line.farend.15min.UAS

3 (seconds)

0-900

OSCM.pmthresholds.line.farend.1day.CV

13120 (B2 count)

0-13219200

OSCM.pmthresholds.line.farend.1day.ES

864 (seconds)

0-86400

OSCM.pmthresholds.line.farend.1day.FC

40 (count)

0-6912

OSCM.pmthresholds.line.farend.1day.SES

4 (seconds)

0-86400

OSCM.pmthresholds.line.farend.1day.UAS

10 (seconds)

0-86400

OSCM.pmthresholds.line.nearend.15min.CV

1312 (B2 count)

0-137700

OSCM.pmthresholds.line.nearend.15min.ES

87 (seconds)

0-900

OSCM.pmthresholds.line.nearend.15min.FC

10 (count)

0-72

OSCM.pmthresholds.line.nearend.15min.SES

1 (seconds)

0-900

OSCM.pmthresholds.line.nearend.15min.UAS

3 (seconds)

0-900

OSCM.pmthresholds.line.nearend.1day.CV

13120 (B2 count)

0-13219200

OSCM.pmthresholds.line.nearend.1day.ES

864 (seconds)

0-86400

OSCM.pmthresholds.line.nearend.1day.FC

40 (count)

0-6912

OSCM.pmthresholds.line.nearend.1day.SES

4 (seconds)

0-86400

OSCM.pmthresholds.line.nearend.1day.UAS

10 (seconds)

0-86400

OSCM.pmthresholds.section.nearend.15min.CV

10000 (B1 count)

0-138600

OSCM.pmthresholds.section.nearend.15min.ES

500 (seconds)

0-900

OSCM.pmthresholds.section.nearend.15min.SEFS

500 (seconds)

0-900

OSCM.pmthresholds.section.nearend.15min.SES

500 (seconds)

0-900

OSCM.pmthresholds.section.nearend.1day.CV

100000 (B1 count)

0-13305600

OSCM.pmthresholds.section.nearend.1day.ES

5000 (seconds)

0-86400

OSCM.pmthresholds.section.nearend.1day.SEFS

5000 (seconds)

0-86400

OSCM.pmthresholds.section.nearend.1day.SES

5000 (seconds)

0-86400


D.2.1.10  OSC-CSM Card Default Settings

Table D-10 lists the OSC-CSM card default settings.

Table D-10 OSC-CSM Card Default Settings (ANSI) 

Default Name
Default Value
Default Domain

OSC_CSM.pmthresholds.line.farend.15min.CV

1312 (B2 count)

0-137700

OSC_CSM.pmthresholds.line.farend.15min.ES

87 (seconds)

0-900

OSC_CSM.pmthresholds.line.farend.15min.FC

10 (count)

0-72

OSC_CSM.pmthresholds.line.farend.15min.SES

1 (seconds)

0-900

OSC_CSM.pmthresholds.line.farend.15min.UAS

3 (seconds)

0-900

OSC_CSM.pmthresholds.line.farend.1day.CV

13120 (B2 count)

0-13219200

OSC_CSM.pmthresholds.line.farend.1day.ES

864 (seconds)

0-86400

OSC_CSM.pmthresholds.line.farend.1day.FC

40 (count)

0-6912

OSC_CSM.pmthresholds.line.farend.1day.SES

4 (seconds)

0-86400

OSC_CSM.pmthresholds.line.farend.1day.UAS

10 (seconds)

0-86400

OSC_CSM.pmthresholds.line.nearend.15min.CV

1312 (B2 count)

0-137700

OSC_CSM.pmthresholds.line.nearend.15min.ES

87 (seconds)

0-900

OSC_CSM.pmthresholds.line.nearend.15min.FC

10 (count)

0-72

OSC_CSM.pmthresholds.line.nearend.15min.SES

1 (seconds)

0-900

OSC_CSM.pmthresholds.line.nearend.15min.UAS

3 (seconds)

0-900

OSC_CSM.pmthresholds.line.nearend.1day.CV

13120 (B2 count)

0-13219200

OSC_CSM.pmthresholds.line.nearend.1day.ES

864 (seconds)

0-86400

OSC_CSM.pmthresholds.line.nearend.1day.FC

40 (count)

0-6912

OSC_CSM.pmthresholds.line.nearend.1day.SES

4 (seconds)

0-86400

OSC_CSM.pmthresholds.line.nearend.1day.UAS

10 (seconds)

0-86400

OSC_CSM.pmthresholds.section.nearend.15min.CV

10000 (B1 count)

0-138600

OSC_CSM.pmthresholds.section.nearend.15min.ES

500 (seconds)

0-900

OSC_CSM.pmthresholds.section.nearend.15min.SEFS

500 (seconds)

0-900

OSC_CSM.pmthresholds.section.nearend.15min.SES

500 (seconds)

0-900

OSC_CSM.pmthresholds.section.nearend.1day.CV

100000 (B1 count)

0-13305600

OSC_CSM.pmthresholds.section.nearend.1day.ES

5000 (seconds)

0-86400

OSC_CSM.pmthresholds.section.nearend.1day.SEFS

5000 (seconds)

0-86400

OSC_CSM.pmthresholds.section.nearend.1day.SES

5000 (seconds)

0-86400


D.2.2  ANSI Node Default Settings

Table D-11 lists the node-level default settings for the Cisco ONS 15454. Cisco provides the following types of user-configurable defaults for each Cisco ONS 15454 node:

Create TL1-Like—Instructs the node to create only cross-connects, allowing the resulting circuits to be in an upgradable state.

Insert AIS-V on SDP—Instructs the node to insert AIS-V in each VT whenever the carrying STS crosses the signal degrade path BER threshold.

SDP BER—Defines the node SD path bit error rate.

Path Protection settings—Set the threshold level for signal degradation and failure for path protection circuits.

Craft Access Only—Allows CTC connectivity to the node only through the craft access port.

CTC IP Display Suppression—Prevents display of node IP addresses in CTC (applicable for all users except Superusers).

Defaults Description—Names the current defaults file on the node.

Enable Firewall—Enables or disables the use of a firewall for accessing the node.

Enable Proxy—Enables or disables the use of a proxy server with the node.

IIOP Listener Port—Sets the Internet Inter-Object Request Broker Protocol (IIOP) listener port number.

LCD IP setting—Sets the node LCD screen to display the node IP address and use the buttons on the LCD panel, only display the IP address, or suppress display of the IP address.

Login Warning Message—Warns users at the login screen about the possible legal or contractual ramifications of accessing equipment, systems, or networks without authorization.

NTP SNTP Server—Sets the IP address of the Network Time Protocol (NTP) Simple Network Time Protocol (SNTP) server to be used with the node.

Time Zone—Sets the time zone where the node is located.

Use DST—Enables or disables the use of Daylight Savings Time (DST).

Use NTP SNTP Server—Enables or disables the use of the specified NTP SNTP server with the node.

1+1 protection settings—Determine whether 1+1 protected circuits have bidirectional switching, are revertive, and what the reversion time is.

BLSR Protection settings—Determine whether BLSR-protected circuits are revertive and what the reversion time is at both the ring and span levels.

Y Cable Protection settings—Determine whether Y-Cable protected circuits have bidirectional switching, are revertive, and what the reversion time is.

Security Policy settings—Determine the allowable failed logins before lockout, idle user timeout for each user level, optional lockout duration or manual unlock enabled, password reuse and change frequency policies, number of characters difference between the old and new password, password aging by security level, enforced single concurrent session per user, and option to disable inactive user after a set inactivity period.

BITS Timing settings—Determine the AIS threshold, coding, framing, State, State Out, and LBO settings for BITS1 and BITS2 timing.

General Timing settings—Determine the mode (External, Line, or Mixed), quality of RES, revertive, reversion time, and SSM message set for node timing.


Note For more information about each individual node setting, see Chapter 10, "Manage the Node."


Table D-11 Node Default Settings (ANSI) 

Default Name
Default Value
Default Domain

NODE.circuits.SendPDIP

FALSE

TRUE, FALSE

NODE.circuits.State

IS,AINS

IS, OOS,DSBLD, OOS,MT, IS,AINS

NODE.circuits.upsr.AllowUpsrOverOnePlusOne

FALSE

TRUE, FALSE

NODE.circuits.upsr.ReversionTime

5.0 (minutes)

0.5, 1.0, 1.5 .. 12.0

NODE.circuits.upsr.Revertive

FALSE

TRUE, FALSE

NODE.circuits.upsr.STS_SDBER

1.00E-06

1E-5, 1E-6, 1E-7, 1E-8, 1E-9

NODE.circuits.upsr.STS_SFBER

1.00E-04

1E-3, 1E-4, 1E-5

NODE.circuits.upsr.SwitchOnPDIP

FALSE

TRUE, FALSE

NODE.circuits.upsr.VT_SDBER

1.00E-06

1E-5, 1E-6, 1E-7, 1E-8

NODE.circuits.upsr.VT_SFBER

1.00E-04

1E-3, 1E-4, 1E-5

NODE.general.DefaultsDescription

Factory Defaults

Free form field

NODE.general.InsertAISVOnSDP

FALSE

TRUE, FALSE

NODE.general.NtpSntpServer

0.0.0.0

IP Address

NODE.general.RaiseConditionOnEmptySlot

FALSE

TRUE, FALSE

NODE.general.SDPBER

1.00E-06

1E-5, 1E-6, 1E-7, 1E-8, 1E-9

NODE.general.TimeZone

(GMT-08:00) Pacific Time (US & Canada), Tijuana

(For applicable time zones, see Table D-24.)

NODE.general.UseDST

TRUE

TRUE, FALSE

NODE.network.general.AlarmMissingBackplaneLAN

FALSE

TRUE, FALSE

NODE.network.general.CtcIpDisplaySuppression

FALSE

TRUE, FALSE

NODE.network.general.GatewaySettings

None

LeaveAsIs, None, ENE, GNE, ProxyOnlyNode

NODE.network.general.LcdIpSetting

Allow Configuration

Allow Configuration, Display Only, Suppress Display

NODE.osi.greTunnel.ctc.OspfCost

110

110, 120, 130 .. 65530

NODE.osi.greTunnel.ctc.SubnetMask

24 (bits)

8, 9, 10 .. 32

NODE.osi.lapd.ctc.Mode

AITS

AITS, UITS

NODE.osi.lapd.ctc.MTU

512

512, 513, 514 .. 1500

NODE.osi.lapd.ctc.Role

Network

Network, User

NODE.osi.lapd.ctc.T200

200 (ms)

200, 300, 400 .. 20000

NODE.osi.lapd.ctc.T203

10000 (ms)

4000, 4100, 4200 .. 120000

NODE.osi.mainSetup.L1L2LSPBufferSize

512 (bytes)

512-1500

NODE.osi.mainSetup.L1LSPBufferSize

512 (bytes)

512-1500

NODE.osi.mainSetup.NodeRoutingMode

Intermediate System Level 1

End System, Intermediate System Level 1, Intermediate System Level 1/Level 2

NODE.osi.subnet.ctc.DISPriority

63

1, 2, 3 .. 127

NODE.osi.subnet.ctc.ESH

10 (sec)

10, 20, 30 .. 1000

NODE.osi.subnet.ctc.GCCISISCost

60

1, 2, 3 .. 63

NODE.osi.subnet.ctc.IIH

3 (sec)

1, 2, 3 .. 600

NODE.osi.subnet.ctc.ISH

10 (sec)

10, 20, 30 .. 1000

NODE.osi.subnet.ctc.LANISISCost

20

1, 2, 3 .. 63

NODE.osi.subnet.ctc.LDCCISISCost

40

1, 2, 3 .. 63

NODE.osi.subnet.ctc.OSCISISCost

60

1, 2, 3 .. 63

NODE.osi.subnet.ctc.SDCCISISCost

60

1, 2, 3 .. 63

NODE.osi.tarp.L1DataCache

TRUE

FALSE, TRUE

NODE.osi.tarp.L2DataCache

FALSE

FALSE, TRUE

NODE.osi.tarp.LANStormSuppression

TRUE

FALSE, TRUE

NODE.osi.tarp.LDB

TRUE

FALSE, TRUE

NODE.osi.tarp.LDBEntry

5 (min)

1-10

NODE.osi.tarp.LDBFlush

5 (sec)

0-1440

NODE.osi.tarp.PDUsL1Propagation

TRUE

FALSE, TRUE

NODE.osi.tarp.PDUsL2Propagation

TRUE

FALSE, TRUE

NODE.osi.tarp.PDUsOrigination

TRUE

FALSE, TRUE

NODE.osi.tarp.T1Timer

15 (sec)

0-3600

NODE.osi.tarp.T2Timer

25 (sec)

0-3600

NODE.osi.tarp.T3Timer

40 (sec)

0-3600

NODE.osi.tarp.T4Timer

20 (sec)

0-3600

NODE.osi.tarp.Type4PDUDelay

0 (sec)

0-255

NODE.powerMonitor.EHIBATVG

-56.5 (Vdc)

-54.0, -54.5, -55.0, -55.5, -56.0, -56.5

NODE.powerMonitor.ELWBATVG

-40.5 (Vdc)

-40.5, -41.0, -41.5, -42.0, -42.5, -43.0, -43.5, -44.0

NODE.powerMonitor.HIBATVG

-54.0 (Vdc)

-44.0, -44.5, -45.0 .. -56.5

NODE.powerMonitor.LWBATVG

-44.0 (Vdc)

-40.5, -41.0, -41.5 .. -54.0

NODE.protection.1+1.BidirectionalSwitching

FALSE

TRUE, FALSE

NODE.protection.1+1.DetectionGuardTimer

1 (seconds)

0, 0.05, 0.1, 0.5, 1, 2, 3, 4, 5

NODE.protection.1+1.RecoveryGuardTimer

1 (seconds)

0, 0.05, 0.1 .. 10

NODE.protection.1+1.ReversionTime

5.0 (minutes)

0.5, 1.0, 1.5 .. 12.0

NODE.protection.1+1.Revertive

FALSE

TRUE, FALSE

NODE.protection.1+1.VerifyGuardTimer

0.5 (seconds)

0.5, 1

NODE.protection.blsr.RingReversionTime

5.0 (minutes)

0.5, 1.0, 1.5 .. 12.0

NODE.protection.blsr.RingRevertive

TRUE

TRUE, FALSE

NODE.protection.blsr.SpanReversionTime

5.0 (minutes)

0.5, 1.0, 1.5 .. 12.0

NODE.protection.blsr.SpanRevertive

TRUE

TRUE, FALSE

NODE.protection.splitter.ReversionTime

5.0 (minutes)

0.5, 1.0, 1.5 .. 12.0

NODE.protection.splitter.Revertive

FALSE

TRUE, FALSE

NODE.protection.ycable.ReversionTime

5.0 (minutes)

0.5, 1.0, 1.5 .. 12.0

NODE.protection.ycable.Revertive

FALSE

TRUE, FALSE

NODE.security.dataComm.ctc.DefaultTCCEthernetIP

10.0.0.1

IP Address

NODE.security.dataComm.ctc.DefaultTCCEthernetIPNetmask

24 (bits)

8, 9, 10 .. 32

NODE.security.dataComm.CtcBackplaneIpDisplaySuppression

(NOT SUPPORTED)

FALSE, TRUE when isSecureModeSupportedOnControlCard is TRUE

(NOT SUPPORTED) when isSecureModeSupportedOnControlCard is FALSE

NODE.security.dataComm.isSecureModeSupportedOnControlCard

FALSE

FALSE, TRUE

NODE.security.dataComm.LcdBackplaneIpSetting

(NOT SUPPORTED)

Allow Configuration, Display Only, Suppress Display when isSecureModeSupportedOnControlCard is TRUE

(NOT SUPPORTED) when isSecureModeSupportedOnControlCard is FALSE

NODE.security.dataComm.SecureModeLocked

(NOT SUPPORTED)

FALSE, TRUE when isSecureModeSupportedOnControlCard is TRUE

(NOT SUPPORTED) when isSecureModeSupportedOnControlCard is FALSE

NODE.security.dataComm.SecureModeOn (May reboot node)

(NOT SUPPORTED)

FALSE, TRUE when isSecureModeSupportedOnControlCard is TRUE

(NOT SUPPORTED) when isSecureModeSupportedOnControlCard is FALSE

NODE.security.emsAccess.AccessState

NonSecure

NonSecure, Secure

NODE.security.emsAccess.IIOPListenerPort (May reboot node)

57790 (port #)

0-65535

NODE.security.idleUserTimeout.Maintenance

01:00 (hours:mins)

00:00, 00:01, 00:02 .. 16:39

NODE.security.idleUserTimeout.Provisioning

00:30 (hours:mins)

00:00, 00:01, 00:02 .. 16:39

NODE.security.idleUserTimeout.Retrieve

00:00 (hours:mins)

00:00, 00:01, 00:02 .. 16:39

NODE.security.idleUserTimeout.Superuser

00:15 (hours:mins)

00:00, 00:01, 00:02 .. 16:39

NODE.security.lanAccess.LANAccess (May disconnect CTC from node)

Front & Backplane

No LAN Access, Front Only, Backplane Only, Front & Backplane

NODE.security.lanAccess.RestoreTimeout

5 (minutes)

0-60

NODE.security.legalDisclaimer.LoginWarningMessage

<html><center><b>WARNING</b></center>This system is restricted to authorized users for business purposes. Unauthorized<p>access is a violation of the law. This service may be monitored for administrative<p>and security reasons. By proceeding, you consent to this monitoring.

Free form field

NODE.security.other.DisableInactiveUser

FALSE

FALSE, TRUE

NODE.security.other.InactiveDuration

45 (days)

1, 2, 3 .. 99 when DisableInactiveUser is TRUE

45 (and N/A) when DisableInactiveUser is FALSE

NODE.security.other.PMClearingPrivilege

Provisioning

Provisioning, Superuser

NODE.security.other.SingleSessionPerUser

FALSE

TRUE, FALSE

NODE.security.passwordAging.EnforcePasswordAging

FALSE

TRUE, FALSE

NODE.security.passwordAging.maintenance.AgingPeriod

45 (days)

20-90

NODE.security.passwordAging.maintenance.WarningPeriod

5 (days)

2-20

NODE.security.passwordAging.provisioning.AgingPeriod

45 (days)

20-90

NODE.security.passwordAging.provisioning.WarningPeriod

5 (days)

2-20

NODE.security.passwordAging.retrieve.AgingPeriod

45 (days)

20-90

NODE.security.passwordAging.retrieve.WarningPeriod

5 (days)

2-20

NODE.security.passwordAging.superuser.AgingPeriod

45 (days)

20-90

NODE.security.passwordAging.superuser.WarningPeriod

5 (days)

2-20

NODE.security.passwordChange.CannotChangeNewPassword

FALSE

TRUE, FALSE

NODE.security.passwordChange.CannotChangeNewPasswordForNDays

20 (days)

20-95

NODE.security.passwordChange.NewPasswordMustDifferFromOldByNCharacters

1 (characters)

1-20

NODE.security.passwordChange.PreventReusingLastNPasswords

1 (times)

1-10

NODE.security.passwordChange.RequirePasswordChangeOnFirstLoginToNewAccount

FALSE

TRUE, FALSE

NODE.security.radiusServer.ctc.AccountingPort

1813 (port)

0-32767

NODE.security.radiusServer.ctc.AuthenticationPort

1812 (port)

0-32767

NODE.security.radiusServer.EnableNodeAsFinalAuthenticatorWhenAuthenticationEnabled

TRUE

FALSE, TRUE

NODE.security.serialCraftAccess.EnableCraftPort

TRUE

TRUE, FALSE

NODE.security.shellAccess.AccessState

NonSecure

Disabled, NonSecure, Secure

NODE.security.shellAccess.EnableShellPassword

FALSE

TRUE, FALSE

NODE.security.shellAccess.TelnetPort

23

23-9999

NODE.security.snmpAccess.AccessState

NonSecure

Disabled, NonSecure

NODE.security.tl1Access.AccessState

NonSecure

Disabled, NonSecure, Secure

NODE.security.userLockout.FailedLoginsAllowedBeforeLockout

5 (times)

0-10

NODE.security.userLockout.LockoutDuration

00:30 (mins:secs)

00:00, 00:05, 00:10 .. 10:00

NODE.security.userLockout.ManualUnlockBySuperuser

FALSE

TRUE, FALSE

NODE.timing.bits-1.AdminSSMIn

STU

PRS, STU, ST2, TNC, ST3E, ST3, SMC, ST4, DUS, RES

NODE.timing.bits-1.AISThreshold

SMC

PRS, STU, ST2, TNC, ST3E, ST3, SMC, ST4, DUS, RES

NODE.timing.bits-1.Coding

B8ZS

B8ZS, AMI when FacilityType is DS1

AMI when FacilityType is 64kHz+8kHz

NODE.timing.bits-1.CodingOut

B8ZS

B8ZS, AMI when FacilityTypeOut is DS1

AMI when FacilityTypeOut is 6MHz

NODE.timing.bits-1.FacilityType

DS1

DS1, 64kHz+8kHz

NODE.timing.bits-1.FacilityTypeOut

DS1

DS1, 6MHz

NODE.timing.bits-1.Framing

ESF

ESF, D4 when FacilityType is DS1

N/A when FacilityType is 64kHz+8kHz

NODE.timing.bits-1.FramingOut

ESF

ESF, D4 when FacilityTypeOut is DS1

N/A when FacilityTypeOut is 6MHz

NODE.timing.bits-1.LBO

0-133

0-133, 134-266, 267-399, 400-533, 534-655

NODE.timing.bits-1.State

IS

IS, OOS,DSBLD

NODE.timing.bits-1.StateOut

IS

IS, OOS,DSBLD

NODE.timing.bits-2.AdminSSMIn

STU

PRS, STU, ST2, TNC, ST3E, ST3, SMC, ST4, DUS, RES

NODE.timing.bits-2.AISThreshold

SMC

PRS, STU, ST2, TNC, ST3E, ST3, SMC, ST4, DUS, RES

NODE.timing.bits-2.Coding

B8ZS

B8ZS, AMI when FacilityType is DS1

AMI when FacilityType is 64kHz+8kHz

NODE.timing.bits-2.CodingOut

B8ZS

B8ZS, AMI when FacilityTypeOut is DS1

AMI when FacilityTypeOut is 6MHz

NODE.timing.bits-2.FacilityType

DS1

DS1, 64kHz+8kHz

NODE.timing.bits-2.FacilityTypeOut

DS1

DS1, 6MHz

NODE.timing.bits-2.Framing

ESF

ESF, D4 when FacilityType is DS1

N/A when FacilityType is 64kHz+8kHz

NODE.timing.bits-2.FramingOut

ESF

ESF, D4 when FacilityTypeOut is DS1;

N/A when FacilityTypeOut is 6MHz

NODE.timing.bits-2.LBO

0-133

0-133, 134-266, 267-399, 400-533, 534-655

NODE.timing.bits-2.State

IS

IS, OOS,DSBLD

NODE.timing.bits-2.StateOut

IS

IS, OOS,DSBLD

NODE.timing.general.Mode

External

External, Line, Mixed

NODE.timing.general.QualityOfRES

RES=DUS

PRS<RES, STU<RES<PRS, ST2<RES<STU, ST3<RES<ST2, SMC<RES<ST3, ST4<RES<SMC, RES<ST4, RES=DUS when SSMMessageSet is Generation 1

PRS<RES, STU<RES<PRS, ST2<RES<STU, TNC<RES<ST2, ST3E<RES<TNC, ST3<RES<ST3E, SMC<RES<ST3, ST4<RES<SMC, RES<ST4, RES=DUS when SSMMessageSet is Generation 2

NODE.timing.general.ReversionTime

5.0 (minutes)

0.5, 1.0, 1.5 .. 12.0

NODE.timing.general.Revertive

FALSE

TRUE, FALSE

NODE.timing.general.SSMMessageSet

Generation 1

Generation 1, Generation 2


D.2.3  ANSI CTC Default Settings

Table D-12 lists the CTC-level default settings for the Cisco ONS 15454. Cisco provides the following types of user-configurable defaults for CTC.

Create circuits with the Route Automatically check box selected by default.

Create TL1-like circuits—Instructs the node to create only cross-connects, allowing the resulting circuits to be in an upgradable state.

Choose a default network map (which country).

Table D-12 CTC default settings (ANSI) 

Default Name
Default Value
Default Domain

CTC.circuits.AutoRoute

TRUE

TRUE, FALSE

CTC.circuits.CreateLikeTL1

FALSE

TRUE, FALSE

CTC.network.Map

United States

-none-, Germany, Japan, Netherlands, South Korea, United Kingdom, United States


D.3  ETSI Platform Defaults

The following sections give the NE defaults for the 15454 ETSI platform. To see defaults for the 15454 ANSI platform, see the "ANSI Platform Defaults" section.

D.3.1  ETSI Card Default Settings

The tables in this section list the default settings for each DWDM, TXP, and MXP card. For all other cards, including optical, electrical, Ethernet, and Fibre Channel, refer to the Cisco ONS 15454 SDH Reference Manual.

Cisco provides user-configurable defaults for the Cisco ONS 15454 cards, including:

Soak Time—All cards. The length of time that elapses between an AINS port receiving a valid signal and when it automatically changes to in-service status.

Port State (config state)—All cards. Sets the port to one of the five available administrative states (unlocked; locked,disabled; locked,maintenance; unlocked,automaticInService), depending on whether you need ports in or out of service.

SF BER Level—TXP and MXP cards. Defines the signal fail bit error rate.

SD BER Level—TXP and MXP cards. Defines the signal degrade bit error rate.

Enable Sync Messages—MXP cards. Enables synchronization status messages (S1 byte), which allow the node to choose the best timing source.

Send Do Not Use—TXP and MXP cards. Sends a DUS message on the S1 byte when enabled.

Payload Type—TXP and MXP cards. Defines the type of client signal.

Termination Mode—TXP and MXP cards. Defines the type of termination (line, section, or transparent).

ALS Mode—TXP and MXP cards. Sets the automatic laser shutdown feature to one of four available states (disabled, auto restart, manual restart, manual restart for test).

ALS Recovery Interval—TXP and MXP cards. Sets the automatic laser shutdown recovery time interval.

ALS Recovery Pulse Width—TXP and MXP cards. Sets the automatic laser shutdown recovery pulse signal width.

FEC—TXP and MXP cards. Enables or disables the FEC monitoring on the optical transport network.

G.709 OTN—TXP and MXP cards. Enables or disables the ITU-T G.709 monitoring on the optical transport network.

FEC Thresholds—TXP and MXP cards. Set the performance monitoring parameters for gathering FEC performance data and detecting problems early.

Optical Thresholds—TXP and MXP cards. Set the performance monitoring parameters for gathering physical optics performance data and detecting problems early.

OTN Thresholds—TXP and MXP cards. Set the performance monitoring parameters for gathering OTN trunk-side performance data and detecting problems early.

PM Threshold settings—All cards. Set the performance monitoring parameters for gathering performance data and detecting problems early.


Note For more information about each individual card setting, see "Change DWDM Card Settings."



Note For more information about the performance monitoring parameters, see the Chapter 9, "Monitor Performance."


D.3.1.1  MXP_2.5G_10G Card Default Settings

Table D-13 lists the MXP_2.5G_10G card default settings.

Table D-13 MXP_2.5G_10G Card Default Settings (ETSI) 

Default Name
Default Value
Default Domain

MXP-2_5G-10G.config.client.AINSSoakTime

08:00 (hours:mins)

00:00, 00:15, 00:30 .. 48:00

MXP-2_5G-10G.config.client.AlsMode

Disabled

Disabled, Auto Restart, Manual Restart, Manual Restart for Test

MXP-2_5G-10G.config.client.AlsRecoveryPulseDuration

4.0 (seconds)

2.0, 2.1, 2.2 .. 100.0 when AlsMode is Disabled, Auto Restart, Manual Restart

80.0, 80.1, 80.2 .. 100.0 when AlsMode is Manual Restart for Test

MXP-2_5G-10G.config.client.AlsRecoveryPulseInterval

100 (seconds)

60-300

MXP-2_5G-10G.config.client.ppmPortAssignment

STM16_PORT

UNASSIGNED, STM16_PORT

MXP-2_5G-10G.config.client.ppmSlotAssignment

UNASSIGNED

UNASSIGNED, PPM (1 Port)

MXP-2_5G-10G.config.client.SDBER

1E-7

1E-5, 1E-6, 1E-7, 1E-8, 1E-9

MXP-2_5G-10G.config.client.SendDoNotUse

FALSE

TRUE, FALSE

MXP-2_5G-10G.config.client.SFBER

1E-4

1E-3, 1E-4, 1E-5

MXP-2_5G-10G.config.client.SyncMsgIn

TRUE

FALSE, TRUE

MXP-2_5G-10G.config.client.TerminationMode

Transparent

Transparent, Multiplex Section

MXP-2_5G-10G.config.trunk.AINSSoakTime

08:00 (hours:mins)

00:00, 00:15, 00:30 .. 48:00

MXP-2_5G-10G.config.trunk.AlsMode

Disabled

Disabled, Auto Restart, Manual Restart, Manual Restart for Test

MXP-2_5G-10G.config.trunk.AlsRecoveryPulseDuration

4.0 (seconds)

2.0, 2.1, 2.2 .. 100.0 when AlsMode is Disabled, Auto Restart, Manual Restart

80.0, 80.1, 80.2 .. 100.0 when AlsMode is Manual Restart for Test

MXP-2_5G-10G.config.trunk.AlsRecoveryPulseInterval

100 (seconds)

60-300

MXP-2_5G-10G.opticalthresholds.client.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10G.opticalthresholds.client.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.alarm.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.alarm.LowRxPower

-21.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10G.opticalthresholds.client.alarm.LowTxPower

-8.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10G.opticalthresholds.client.warning.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10G.opticalthresholds.client.warning.15min.HighRxPower

2.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.warning.15min.HighTxPower

2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.warning.15min.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10G.opticalthresholds.client.warning.15min.LowTxPower

-7.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10G.opticalthresholds.client.warning.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10G.opticalthresholds.client.warning.1day.HighRxPower

2.5 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.warning.1day.HighTxPower

2.5 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.client.warning.1day.LowRxPower

-20.5 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10G.opticalthresholds.client.warning.1day.LowTxPower

-7.5 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10G.opticalthresholds.trunk.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10G.opticalthresholds.trunk.alarm.HighRxPower

-8.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.trunk.alarm.HighTxPower

4.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.trunk.alarm.LowRxPower

-25.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10G.opticalthresholds.trunk.alarm.LowTxPower

2.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10G.opticalthresholds.trunk.warning.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10G.opticalthresholds.trunk.warning.15min.HighRxPower

-7.5 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.trunk.warning.15min.HighTxPower

3.5 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.trunk.warning.15min.LowRxPower

-24.5 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10G.opticalthresholds.trunk.warning.15min.LowTxPower

2.5 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10G.opticalthresholds.trunk.warning.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10G.opticalthresholds.trunk.warning.1day.HighRxPower

-7.3 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.trunk.warning.1day.HighTxPower

3.7 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-2_5G-10G.opticalthresholds.trunk.warning.1day.LowRxPower

-24.7 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-2_5G-10G.opticalthresholds.trunk.warning.1day.LowTxPower

2.3 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-2_5G-10G.otn.fecthresholds.standard.15min.BitErrorsCorrected

903330 (count)

0-9033621811200

MXP-2_5G-10G.otn.fecthresholds.standard.15min.UncorrectableWords

5 (count)

0-4724697600

MXP-2_5G-10G.otn.fecthresholds.standard.1day.BitErrorsCorrected

86719680 (count)

0-867227693875200

MXP-2_5G-10G.otn.fecthresholds.standard.1day.UncorrectableWords

480 (count)

0-453570969600

MXP-2_5G-10G.otn.g709thresholds.pm.farend.15min.BBE

85040 (count)

0-8850600

MXP-2_5G-10G.otn.g709thresholds.pm.farend.15min.ES

87 (seconds)

0-900

MXP-2_5G-10G.otn.g709thresholds.pm.farend.15min.FC

10 (count)

0-72

MXP-2_5G-10G.otn.g709thresholds.pm.farend.15min.SES

1 (seconds)

0-900

MXP-2_5G-10G.otn.g709thresholds.pm.farend.15min.UAS

3 (seconds)

0-900

MXP-2_5G-10G.otn.g709thresholds.pm.farend.1day.BBE

850400 (count)

0-849657600

MXP-2_5G-10G.otn.g709thresholds.pm.farend.1day.ES

864 (seconds)

0-86400

MXP-2_5G-10G.otn.g709thresholds.pm.farend.1day.FC

40 (count)

0-6912

MXP-2_5G-10G.otn.g709thresholds.pm.farend.1day.SES

4 (seconds)

0-86400

MXP-2_5G-10G.otn.g709thresholds.pm.farend.1day.UAS

10 (seconds)

0-86400

MXP-2_5G-10G.otn.g709thresholds.pm.nearend.15min.BBE

85040 (count)

0-8850600

MXP-2_5G-10G.otn.g709thresholds.pm.nearend.15min.ES

87 (seconds)

0-900

MXP-2_5G-10G.otn.g709thresholds.pm.nearend.15min.FC

10 (count)

0-72

MXP-2_5G-10G.otn.g709thresholds.pm.nearend.15min.SES

1 (seconds)

0-900

MXP-2_5G-10G.otn.g709thresholds.pm.nearend.15min.UAS

3 (seconds)

0-900

MXP-2_5G-10G.otn.g709thresholds.pm.nearend.1day.BBE

850400 (count)

0-849657600

MXP-2_5G-10G.otn.g709thresholds.pm.nearend.1day.ES

864 (seconds)

0-86400

MXP-2_5G-10G.otn.g709thresholds.pm.nearend.1day.FC

40 (count)

0-6912

MXP-2_5G-10G.otn.g709thresholds.pm.nearend.1day.SES

4 (seconds)

0-86400

MXP-2_5G-10G.otn.g709thresholds.pm.nearend.1day.UAS

10 (seconds)

0-86400

MXP-2_5G-10G.otn.g709thresholds.sm.farend.15min.BBE

10000 (count)

0-8850600

MXP-2_5G-10G.otn.g709thresholds.sm.farend.15min.ES

500 (seconds)

0-900

MXP-2_5G-10G.otn.g709thresholds.sm.farend.15min.FC

10 (count)

0-72

MXP-2_5G-10G.otn.g709thresholds.sm.farend.15min.SES

500 (seconds)

0-900

MXP-2_5G-10G.otn.g709thresholds.sm.farend.15min.UAS

500 (seconds)

0-900

MXP-2_5G-10G.otn.g709thresholds.sm.farend.1day.BBE

100000 (count)

0-849657600

MXP-2_5G-10G.otn.g709thresholds.sm.farend.1day.ES

5000 (seconds)

0-86400

MXP-2_5G-10G.otn.g709thresholds.sm.farend.1day.FC

40 (count)

0-6912

MXP-2_5G-10G.otn.g709thresholds.sm.farend.1day.SES

5000 (seconds)

0-86400

MXP-2_5G-10G.otn.g709thresholds.sm.farend.1day.UAS

5000 (seconds)

0-86400

MXP-2_5G-10G.otn.g709thresholds.sm.nearend.15min.BBE

10000 (count)

0-8850600

MXP-2_5G-10G.otn.g709thresholds.sm.nearend.15min.ES

500 (seconds)

0-900

MXP-2_5G-10G.otn.g709thresholds.sm.nearend.15min.FC

10 (count)

0-72

MXP-2_5G-10G.otn.g709thresholds.sm.nearend.15min.SES

500 (seconds)

0-900

MXP-2_5G-10G.otn.g709thresholds.sm.nearend.15min.UAS

500 (seconds)

0-900

MXP-2_5G-10G.otn.g709thresholds.sm.nearend.1day.BBE

100000 (count)

0-849657600

MXP-2_5G-10G.otn.g709thresholds.sm.nearend.1day.ES

5000 (seconds)

0-86400

MXP-2_5G-10G.otn.g709thresholds.sm.nearend.1day.FC

40 (count)

0-6912

MXP-2_5G-10G.otn.g709thresholds.sm.nearend.1day.SES

5000 (seconds)

0-86400

MXP-2_5G-10G.otn.g709thresholds.sm.nearend.1day.UAS

5000 (seconds)

0-86400

MXP-2_5G-10G.otn.otnLines.FEC

Standard

Disable, Standard, Enhanced when G709OTN is Enable

Disable when G709OTN is Disable

MXP-2_5G-10G.otn.otnLines.G709OTN

Enable

Disable, Enable

MXP-2_5G-10G.otn.otnLines.SDBER

1E-7

1E-5, 1E-6, 1E-7, 1E-8, 1E-9

MXP-2_5G-10G.pmthresholds.client.ms.farend.15min.BBE

21260 (count)

0-2212200

MXP-2_5G-10G.pmthresholds.client.ms.farend.15min.EB

21260 (count)

0-2212200

MXP-2_5G-10G.pmthresholds.client.ms.farend.15min.ES

87 (seconds)

0-900

MXP-2_5G-10G.pmthresholds.client.ms.farend.15min.SES

1 (seconds)

0-900

MXP-2_5G-10G.pmthresholds.client.ms.farend.15min.UAS

3 (seconds)

0-900

MXP-2_5G-10G.pmthresholds.client.ms.farend.1day.BBE

212600 (count)

0-212371200

MXP-2_5G-10G.pmthresholds.client.ms.farend.1day.EB

212600 (count)

0-212371200

MXP-2_5G-10G.pmthresholds.client.ms.farend.1day.ES

864 (seconds)

0-86400

MXP-2_5G-10G.pmthresholds.client.ms.farend.1day.SES

4 (seconds)

0-86400

MXP-2_5G-10G.pmthresholds.client.ms.farend.1day.UAS

10 (seconds)

0-86400

MXP-2_5G-10G.pmthresholds.client.ms.nearend.15min.BBE

21260 (count)

0-2212200

MXP-2_5G-10G.pmthresholds.client.ms.nearend.15min.EB

21260 (count)

0-2212200

MXP-2_5G-10G.pmthresholds.client.ms.nearend.15min.ES

87 (seconds)

0-900

MXP-2_5G-10G.pmthresholds.client.ms.nearend.15min.SES

1 (seconds)

0-900

MXP-2_5G-10G.pmthresholds.client.ms.nearend.15min.UAS

3 (seconds)

0-900

MXP-2_5G-10G.pmthresholds.client.ms.nearend.1day.BBE

212600 (count)

0-212371200

MXP-2_5G-10G.pmthresholds.client.ms.nearend.1day.EB

212600 (count)

0-212371200

MXP-2_5G-10G.pmthresholds.client.ms.nearend.1day.ES

864 (seconds)

0-86400

MXP-2_5G-10G.pmthresholds.client.ms.nearend.1day.SES

4 (seconds)

0-86400

MXP-2_5G-10G.pmthresholds.client.ms.nearend.1day.UAS

10 (seconds)

0-86400

MXP-2_5G-10G.pmthresholds.client.rs.nearend.15min.BBE

10000 (count)

0-2212200

MXP-2_5G-10G.pmthresholds.client.rs.nearend.15min.EB

10000 (count)

0-2151900

MXP-2_5G-10G.pmthresholds.client.rs.nearend.15min.ES

500 (seconds)

0-900

MXP-2_5G-10G.pmthresholds.client.rs.nearend.15min.SES

500 (seconds)

0-900

MXP-2_5G-10G.pmthresholds.client.rs.nearend.15min.UAS

3 (seconds)

0-900

MXP-2_5G-10G.pmthresholds.client.rs.nearend.1day.BBE

100000 (count)

0-212371200

MXP-2_5G-10G.pmthresholds.client.rs.nearend.1day.EB

100000 (count)

0-206582400

MXP-2_5G-10G.pmthresholds.client.rs.nearend.1day.ES

5000 (seconds)

0-86400

MXP-2_5G-10G.pmthresholds.client.rs.nearend.1day.SES

5000 (seconds)

0-86400

MXP-2_5G-10G.pmthresholds.client.rs.nearend.1day.UAS

10 (seconds)

0-86400

MXP-2_5G-10G.pmthresholds.trunk.ms.farend.15min.BBE

85040 (count)

0-8850600

MXP-2_5G-10G.pmthresholds.trunk.ms.farend.15min.EB

85040 (count)

0-8850600

MXP-2_5G-10G.pmthresholds.trunk.ms.farend.15min.ES

87 (seconds)

0-900

MXP-2_5G-10G.pmthresholds.trunk.ms.farend.15min.SES

1 (seconds)

0-900

MXP-2_5G-10G.pmthresholds.trunk.ms.farend.15min.UAS

3 (seconds)

0-900

MXP-2_5G-10G.pmthresholds.trunk.ms.farend.1day.BBE

850400 (count)

0-849657600

MXP-2_5G-10G.pmthresholds.trunk.ms.farend.1day.EB

850400 (count)

0-849657600

MXP-2_5G-10G.pmthresholds.trunk.ms.farend.1day.ES

864 (seconds)

0-86400

MXP-2_5G-10G.pmthresholds.trunk.ms.farend.1day.SES

4 (seconds)

0-86400

MXP-2_5G-10G.pmthresholds.trunk.ms.farend.1day.UAS

10 (seconds)

0-86400

MXP-2_5G-10G.pmthresholds.trunk.ms.nearend.15min.BBE

85040 (count)

0-8850600

MXP-2_5G-10G.pmthresholds.trunk.ms.nearend.15min.EB

85040 (count)

0-8850600

MXP-2_5G-10G.pmthresholds.trunk.ms.nearend.15min.ES

87 (seconds)

0-900

MXP-2_5G-10G.pmthresholds.trunk.ms.nearend.15min.SES

1 (seconds)

0-900

MXP-2_5G-10G.pmthresholds.trunk.ms.nearend.15min.UAS

3 (seconds)

0-900

MXP-2_5G-10G.pmthresholds.trunk.ms.nearend.1day.BBE

850400 (count)

0-849657600

MXP-2_5G-10G.pmthresholds.trunk.ms.nearend.1day.EB

850400 (count)

0-849657600

MXP-2_5G-10G.pmthresholds.trunk.ms.nearend.1day.ES

864 (seconds)

0-86400

MXP-2_5G-10G.pmthresholds.trunk.ms.nearend.1day.SES

4 (seconds)

0-86400

MXP-2_5G-10G.pmthresholds.trunk.ms.nearend.1day.UAS

10 (seconds)

0-86400

MXP-2_5G-10G.pmthresholds.trunk.rs.nearend.15min.BBE

10000 (count)

0-8850600

MXP-2_5G-10G.pmthresholds.trunk.rs.nearend.15min.EB

10000 (count)

0-7967700

MXP-2_5G-10G.pmthresholds.trunk.rs.nearend.15min.ES

500 (seconds)

0-900

MXP-2_5G-10G.pmthresholds.trunk.rs.nearend.15min.SES

500 (seconds)

0-900

MXP-2_5G-10G.pmthresholds.trunk.rs.nearend.15min.UAS

3 (seconds)

0-900

MXP-2_5G-10G.pmthresholds.trunk.rs.nearend.1day.BBE

100000 (count)

0-849657600

MXP-2_5G-10G.pmthresholds.trunk.rs.nearend.1day.EB

100000 (count)

0-764899200

MXP-2_5G-10G.pmthresholds.trunk.rs.nearend.1day.ES

5000 (seconds)

0-86400

MXP-2_5G-10G.pmthresholds.trunk.rs.nearend.1day.SES

5000 (seconds)

0-86400

MXP-2_5G-10G.pmthresholds.trunk.rs.nearend.1day.UAS

10 (seconds)

0-86400


D.3.1.2  MXP_2.5G_10E Card Default Settings

Table D-14 lists the MXP_2.5G_10E card default settings.

Table D-14 MXP_2.5G_10E Card Default Settings (ETSI) 

Default Name
Default Value
Default Domain

MXP-2_5G-10E.config.client.AINSSoakTime

08:00 (hours:mins)

00:00, 00:15, 00:30 .. 48:00

MXP-2_5G-10E.config.client.AisSquelchMode

Squelch

Ais, Squelch

MXP-2_5G-10E.config.client.AlsMode

Disabled

Disabled, Auto Restart, Manual Restart, Manual Restart for Test

MXP-2_5G-10E.config.client.AlsRecoveryPulseDuration

2.0 (seconds)

2.0, 2.1, 2.2 .. 100.0 when AlsMode is Disabled, Auto Restart, Manual Restart

80.0, 80.1, 80.2 .. 100.0 when AlsMode is Manual Restart for Test

MXP-2_5G-10E.config.client.AlsRecoveryPulseInterval

100 (seconds)

100-2000

MXP-2_5G-10E.config.client.ppmPortAssignment

STM16_PORT

UNASSIGNED, STM16_PORT

MXP-2_5G-10E.config.client.ppmSlotAssignment

UNASSIGNED

UNASSIGNED, PPM (1 Port)

MXP-2_5G-10E.config.client.SDBER

1E-7

1E-5, 1E-6, 1E-7, 1E-8, 1E-9

MXP-2_5G-10E.config.client.SendDoNotUse

FALSE

TRUE, FALSE

MXP-2_5G-10E.config.client.SFBER

1E-4

1E-3, 1E-4, 1E-5

MXP-2_5G-10E.config.client.SyncMsgIn

TRUE

FALSE, TRUE

MXP-2_5G-10E.config.client.TerminationMode

Transparent

Transparent, Regeneration Section

MXP-2_5G-10E.config.trunk.AINSSoakTime

08:00 (hours:mins)

00:00, 00:15, 00:30 .. 48:00

MXP-2_5G-10E.config.trunk.AlsMode

Disabled

Disabled, Auto Restart, Manual Restart, Manual Restart for Test

MXP-2_5G-10E.config.trunk.AlsRecoveryPulseDuration

100.0 (seconds)

60.0, 60.1, 60.2 .. 200.0 when AlsMode is Disabled, Auto Restart, Manual Restart

80.0, 80.1, 80.2 .. 100.0 when AlsMode is Manual Restart for Test

MXP-2_5G-10E.config.trunk.AlsRecoveryPulseInterval

300 (seconds)

200-2000

MXP-2_5G-10E.opticalthresholds.client.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10E.opticalthresholds.client.alarm.HighRxPower

3.0 (dBm)

-21.0, -20.9, -20.8 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.alarm.HighTxPower

3.0 (dBm)

-8.0, -7.9, -7.8 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.alarm.LowRxPower

-21.0 (dBm)

-40.0, -39.9, -39.8 .. 3.0

MXP-2_5G-10E.opticalthresholds.client.alarm.LowTxPower

-8.0 (dBm)

-40.0, -39.9, -39.8 .. 3.0

MXP-2_5G-10E.opticalthresholds.client.warning.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10E.opticalthresholds.client.warning.15min.HighRxPower

2.0 (dBm)

-20.0, -19.9, -19.8 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.warning.15min.HighTxPower

2.0 (dBm)

-7.0, -6.9, -6.8 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.warning.15min.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. 2.0

MXP-2_5G-10E.opticalthresholds.client.warning.15min.LowTxPower

-7.0 (dBm)

-40.0, -39.9, -39.8 .. 2.0

MXP-2_5G-10E.opticalthresholds.client.warning.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10E.opticalthresholds.client.warning.1day.HighRxPower

2.5 (dBm)

-20.5, -20.4, -20.3 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.warning.1day.HighTxPower

2.5 (dBm)

-7.5, -7.4, -7.3 .. 30.0

MXP-2_5G-10E.opticalthresholds.client.warning.1day.LowRxPower

-20.5 (dBm)

-40.0, -39.9, -39.8 .. 2.5

MXP-2_5G-10E.opticalthresholds.client.warning.1day.LowTxPower

-7.5 (dBm)

-40.0, -39.9, -39.8 .. 2.5

MXP-2_5G-10E.opticalthresholds.trunk.alarm.HighLaserBias

98.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10E.opticalthresholds.trunk.alarm.HighRxPower

-8.0 (dBm)

-25.0, -24.9, -24.8 .. 30.0

MXP-2_5G-10E.opticalthresholds.trunk.alarm.HighTxPower

8.0 (dBm)

1.0, 1.1, 1.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.trunk.alarm.LowRxPower

-25.0 (dBm)

-40.0, -39.9, -39.8 .. -8.0

MXP-2_5G-10E.opticalthresholds.trunk.alarm.LowTxPower

1.0 (dBm)

-40.0, -39.9, -39.8 .. 8.0

MXP-2_5G-10E.opticalthresholds.trunk.warning.15min.HighLaserBias

95.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10E.opticalthresholds.trunk.warning.15min.HighRxPower

-7.5 (dBm)

-24.5, -24.4, -24.3 .. 30.0

MXP-2_5G-10E.opticalthresholds.trunk.warning.15min.HighTxPower

7.0 (dBm)

2.0, 2.1, 2.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.trunk.warning.15min.LowRxPower

-24.5 (dBm)

-40.0, -39.9, -39.8 .. -7.5

MXP-2_5G-10E.opticalthresholds.trunk.warning.15min.LowTxPower

2.0 (dBm)

-40.0, -39.9, -39.8 .. 7.0

MXP-2_5G-10E.opticalthresholds.trunk.warning.1day.HighLaserBias

96.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-2_5G-10E.opticalthresholds.trunk.warning.1day.HighRxPower

-7.3 (dBm)

-24.7, -24.6, -24.5 .. 30.0

MXP-2_5G-10E.opticalthresholds.trunk.warning.1day.HighTxPower

7.0 (dBm)

2.0, 2.1, 2.2 .. 30.0

MXP-2_5G-10E.opticalthresholds.trunk.warning.1day.LowRxPower

-24.7 (dBm)

-40.0, -39.9, -39.8 .. -7.3

MXP-2_5G-10E.opticalthresholds.trunk.warning.1day.LowTxPower

2.0 (dBm)

-40.0, -39.9, -39.8 .. 7.0

MXP-2_5G-10E.otn.fecthresholds.enhanced.15min.BitErrorsCorrected

903330 (count)

0-9033621811200

MXP-2_5G-10E.otn.fecthresholds.enhanced.15min.UncorrectableWords

5 (count)

0-4724697600

MXP-2_5G-10E.otn.fecthresholds.enhanced.1day.BitErrorsCorrected

86719680 (count)

0-867227693875200

MXP-2_5G-10E.otn.fecthresholds.enhanced.1day.UncorrectableWords

480 (count)

0-453570969600

MXP-2_5G-10E.otn.fecthresholds.standard.15min.BitErrorsCorrected

903330 (count)

0-9033621811200

MXP-2_5G-10E.otn.fecthresholds.standard.15min.UncorrectableWords

5 (count)

0-4724697600

MXP-2_5G-10E.otn.fecthresholds.standard.1day.BitErrorsCorrected

86719680 (count)

0-867227693875200

MXP-2_5G-10E.otn.fecthresholds.standard.1day.UncorrectableWords

480 (count)

0-453570969600

MXP-2_5G-10E.otn.g709thresholds.pm.farend.15min.BBE

85040 (count)

0-8850600

MXP-2_5G-10E.otn.g709thresholds.pm.farend.15min.ES

87 (seconds)

0-900

MXP-2_5G-10E.otn.g709thresholds.pm.farend.15min.FC

10 (count)

0-72

MXP-2_5G-10E.otn.g709thresholds.pm.farend.15min.SES

1 (seconds)

0-900

MXP-2_5G-10E.otn.g709thresholds.pm.farend.15min.UAS

3 (seconds)

0-900

MXP-2_5G-10E.otn.g709thresholds.pm.farend.1day.BBE

850400 (count)

0-849657600

MXP-2_5G-10E.otn.g709thresholds.pm.farend.1day.ES

864 (seconds)

0-86400

MXP-2_5G-10E.otn.g709thresholds.pm.farend.1day.FC

40 (count)

0-6912

MXP-2_5G-10E.otn.g709thresholds.pm.farend.1day.SES

4 (seconds)

0-86400

MXP-2_5G-10E.otn.g709thresholds.pm.farend.1day.UAS

10 (seconds)

0-86400

MXP-2_5G-10E.otn.g709thresholds.pm.nearend.15min.BBE

85040 (count)

0-8850600

MXP-2_5G-10E.otn.g709thresholds.pm.nearend.15min.ES

87 (seconds)

0-900

MXP-2_5G-10E.otn.g709thresholds.pm.nearend.15min.FC

10 (count)

0-72

MXP-2_5G-10E.otn.g709thresholds.pm.nearend.15min.SES

1 (seconds)

0-900

MXP-2_5G-10E.otn.g709thresholds.pm.nearend.15min.UAS

3 (seconds)

0-900

MXP-2_5G-10E.otn.g709thresholds.pm.nearend.1day.BBE

850400 (count)

0-849657600

MXP-2_5G-10E.otn.g709thresholds.pm.nearend.1day.ES

864 (seconds)

0-86400

MXP-2_5G-10E.otn.g709thresholds.pm.nearend.1day.FC

40 (count)

0-6912

MXP-2_5G-10E.otn.g709thresholds.pm.nearend.1day.SES

4 (seconds)

0-86400

MXP-2_5G-10E.otn.g709thresholds.pm.nearend.1day.UAS

10 (seconds)

0-86400

MXP-2_5G-10E.otn.g709thresholds.sm.farend.15min.BBE

10000 (count)

0-8850600

MXP-2_5G-10E.otn.g709thresholds.sm.farend.15min.ES

500 (seconds)

0-900

MXP-2_5G-10E.otn.g709thresholds.sm.farend.15min.FC

10 (count)

0-72

MXP-2_5G-10E.otn.g709thresholds.sm.farend.15min.SES

500 (seconds)

0-900

MXP-2_5G-10E.otn.g709thresholds.sm.farend.15min.UAS

500 (seconds)

0-900

MXP-2_5G-10E.otn.g709thresholds.sm.farend.1day.BBE

100000 (count)

0-849657600

MXP-2_5G-10E.otn.g709thresholds.sm.farend.1day.ES

5000 (seconds)

0-86400

MXP-2_5G-10E.otn.g709thresholds.sm.farend.1day.FC

40 (count)

0-6912

MXP-2_5G-10E.otn.g709thresholds.sm.farend.1day.SES

5000 (seconds)

0-86400

MXP-2_5G-10E.otn.g709thresholds.sm.farend.1day.UAS

5000 (seconds)

0-86400

MXP-2_5G-10E.otn.g709thresholds.sm.nearend.15min.BBE

10000 (count)

0-8850600

MXP-2_5G-10E.otn.g709thresholds.sm.nearend.15min.ES

500 (seconds)

0-900

MXP-2_5G-10E.otn.g709thresholds.sm.nearend.15min.FC

10 (count)

0-72

MXP-2_5G-10E.otn.g709thresholds.sm.nearend.15min.SES

500 (seconds)

0-900

MXP-2_5G-10E.otn.g709thresholds.sm.nearend.15min.UAS

500 (seconds)

0-900

MXP-2_5G-10E.otn.g709thresholds.sm.nearend.1day.BBE

100000 (count)

0-849657600

MXP-2_5G-10E.otn.g709thresholds.sm.nearend.1day.ES

5000 (seconds)

0-86400

MXP-2_5G-10E.otn.g709thresholds.sm.nearend.1day.FC

40 (count)

0-6912

MXP-2_5G-10E.otn.g709thresholds.sm.nearend.1day.SES

5000 (seconds)

0-86400

MXP-2_5G-10E.otn.g709thresholds.sm.nearend.1day.UAS

5000 (seconds)

0-86400

MXP-2_5G-10E.otn.otnLines.AsynchSynchMapping

ODU Multiplex

ODU Multiplex

MXP-2_5G-10E.otn.otnLines.FEC

Standard

Disable, Standard, Enhanced

MXP-2_5G-10E.otn.otnLines.G709OTN

Enable

Enable

MXP-2_5G-10E.otn.otnLines.SDBER

1E-7

1E-5, 1E-6, 1E-7, 1E-8, 1E-9

MXP-2_5G-10E.pmthresholds.client.ms.farend.15min.BBE

21260 (count)

0-2212200

MXP-2_5G-10E.pmthresholds.client.ms.farend.15min.EB

21260 (count)

0-2212200

MXP-2_5G-10E.pmthresholds.client.ms.farend.15min.ES

87 (seconds)

0-900

MXP-2_5G-10E.pmthresholds.client.ms.farend.15min.SES

1 (seconds)

0-900

MXP-2_5G-10E.pmthresholds.client.ms.farend.15min.UAS

3 (seconds)

0-900

MXP-2_5G-10E.pmthresholds.client.ms.farend.1day.BBE

212600 (count)

0-212371200

MXP-2_5G-10E.pmthresholds.client.ms.farend.1day.EB

212600 (count)

0-212371200

MXP-2_5G-10E.pmthresholds.client.ms.farend.1day.ES

864 (seconds)

0-86400

MXP-2_5G-10E.pmthresholds.client.ms.farend.1day.SES

4 (seconds)

0-86400

MXP-2_5G-10E.pmthresholds.client.ms.farend.1day.UAS

10 (seconds)

0-86400

MXP-2_5G-10E.pmthresholds.client.ms.nearend.15min.BBE

21260 (count)

0-2212200

MXP-2_5G-10E.pmthresholds.client.ms.nearend.15min.EB

21260 (count)

0-2212200

MXP-2_5G-10E.pmthresholds.client.ms.nearend.15min.ES

87 (seconds)

0-900

MXP-2_5G-10E.pmthresholds.client.ms.nearend.15min.SES

1 (seconds)

0-900

MXP-2_5G-10E.pmthresholds.client.ms.nearend.15min.UAS

3 (seconds)

0-900

MXP-2_5G-10E.pmthresholds.client.ms.nearend.1day.BBE

212600 (count)

0-212371200

MXP-2_5G-10E.pmthresholds.client.ms.nearend.1day.EB

212600 (count)

0-212371200

MXP-2_5G-10E.pmthresholds.client.ms.nearend.1day.ES

864 (seconds)

0-86400

MXP-2_5G-10E.pmthresholds.client.ms.nearend.1day.SES

4 (seconds)

0-86400

MXP-2_5G-10E.pmthresholds.client.ms.nearend.1day.UAS

10 (seconds)

0-86400

MXP-2_5G-10E.pmthresholds.client.rs.nearend.15min.BBE

10000 (count)

0-2212200

MXP-2_5G-10E.pmthresholds.client.rs.nearend.15min.EB

10000 (count)

0-2151900

MXP-2_5G-10E.pmthresholds.client.rs.nearend.15min.ES

500 (seconds)

0-900

MXP-2_5G-10E.pmthresholds.client.rs.nearend.15min.SES

500 (seconds)

0-900

MXP-2_5G-10E.pmthresholds.client.rs.nearend.15min.UAS

3 (seconds)

0-900

MXP-2_5G-10E.pmthresholds.client.rs.nearend.1day.BBE

100000 (count)

0-212371200

MXP-2_5G-10E.pmthresholds.client.rs.nearend.1day.EB

100000 (count)

0-206582400

MXP-2_5G-10E.pmthresholds.client.rs.nearend.1day.ES

5000 (seconds)

0-86400

MXP-2_5G-10E.pmthresholds.client.rs.nearend.1day.SES

5000 (seconds)

0-86400

MXP-2_5G-10E.pmthresholds.client.rs.nearend.1day.UAS

10 (seconds)

0-86400


D.3.1.3  MXP_MR_2.5G Card Default Settings

Table D-15 lists the MXP_MR_2.5G card default settings.

Table D-15 MXP_MR_2.5G Card Default Settings (ETSI) 

Default Name
Default Value
Default Domain

MXP-MR-2_5G.config.client.AlsMode

Disabled

Disabled, Manual Restart, Manual Restart for Test

MXP-MR-2_5G.config.client.AlsRecoveryPulseDuration

4.0 (seconds)

2.0, 2.1, 2.2 .. 100.0 when AlsMode is Disabled, Auto Restart, Manual Restart

80.0, 80.1, 80.2 .. 100.0 when AlsMode is Manual Restart for Test

MXP-MR-2_5G.config.client.AlsRecoveryPulseInterval

100 (seconds)

60-300

MXP-MR-2_5G.config.client.ppmPortAssignment

UNASSIGNED

UNASSIGNED, ONE_GE, FC1G ISL, FC2G ISL, FICON1G ISL, FICON2G ISL

MXP-MR-2_5G.config.client.ppmSlotAssignment

UNASSIGNED

UNASSIGNED, PPM (1 Port)

MXP-MR-2_5G.config.fc.distanceExtension.AutoadjustGFPBufferThreshold

TRUE

TRUE, FALSE

MXP-MR-2_5G.config.fc.distanceExtension.AutoDetect

TRUE

TRUE, FALSE

MXP-MR-2_5G.config.fc.distanceExtension.Enabled

TRUE

TRUE, FALSE

MXP-MR-2_5G.config.fc.distanceExtension.NumCredits

32

2-256

MXP-MR-2_5G.config.fc.distanceExtension.NumGFPBuffers

16

16, 32, 48 .. 1200

MXP-MR-2_5G.config.fc.enhancedFibreChannelFicon.MaxFrameSize

2148

2148, 2152, 2156, 2160, 2164, 2168, 2172

MXP-MR-2_5G.config.trunk.AINSSoakTime

08:00 (hours:mins)

00:00, 00:15, 00:30 .. 48:00

MXP-MR-2_5G.config.trunk.AlsMode

Disabled

Disabled, Auto Restart, Manual Restart, Manual Restart for Test

MXP-MR-2_5G.config.trunk.AlsRecoveryPulseDuration

4.0 (seconds)

2.0, 2.1, 2.2 .. 100.0 when AlsMode is Disabled, Auto Restart, Manual Restart

80.0, 80.1, 80.2 .. 100.0 when AlsMode is Manual Restart for Test

MXP-MR-2_5G.config.trunk.AlsRecoveryPulseInterval

100 (seconds)

60-300

MXP-MR-2_5G.config.trunk.SDBER

1E-7

1E-5, 1E-6, 1E-7, 1E-8, 1E-9

MXP-MR-2_5G.config.trunk.SendDoNotUse

FALSE

TRUE, FALSE

MXP-MR-2_5G.config.trunk.SFBER

1E-4

1E-3, 1E-4, 1E-5

MXP-MR-2_5G.config.trunk.SyncMsgIn

TRUE

FALSE, TRUE

MXP-MR-2_5G.opticalthresholds.client.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.alarm.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.alarm.LowRxPower

-21.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.alarm.LowTxPower

-8.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.warning.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.warning.15min.HighRxPower

2.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.warning.15min.HighTxPower

2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.warning.15min.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.warning.15min.LowTxPower

-7.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.client.warning.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.client.warning.1day.HighRxPower

2.5 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.warning.1day.HighTxPower

2.5 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.client.warning.1day.LowRxPower

-20.5 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.client.warning.1day.LowTxPower

-7.5 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.trunk.alarm.HighLaserBias

98.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.trunk.alarm.HighRxPower

-8.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.trunk.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.trunk.alarm.LowRxPower

-25.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.trunk.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.trunk.warning.15min.HighLaserBias

95.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.trunk.warning.15min.HighRxPower

-7.5 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.trunk.warning.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.trunk.warning.15min.LowRxPower

-24.5 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.trunk.warning.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.opticalthresholds.trunk.warning.1day.HighLaserBias

96.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXP-MR-2_5G.opticalthresholds.trunk.warning.1day.HighRxPower

-7.3 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.trunk.warning.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXP-MR-2_5G.opticalthresholds.trunk.warning.1day.LowRxPower

-24.7 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXP-MR-2_5G.opticalthresholds.trunk.warning.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXP-MR-2_5G.pmthresholds.trunk.ms.farend.15min.BBE

21260 (count)

0-2212200

MXP-MR-2_5G.pmthresholds.trunk.ms.farend.15min.EB

21260 (count)

0-2212200

MXP-MR-2_5G.pmthresholds.trunk.ms.farend.15min.ES

87 (seconds)

0-900

MXP-MR-2_5G.pmthresholds.trunk.ms.farend.15min.SES

1 (seconds)

0-900

MXP-MR-2_5G.pmthresholds.trunk.ms.farend.15min.UAS

3 (seconds)

0-900

MXP-MR-2_5G.pmthresholds.trunk.ms.farend.1day.BBE

212600 (count)

0-2212200

MXP-MR-2_5G.pmthresholds.trunk.ms.farend.1day.EB

212600 (count)

0-212371200

MXP-MR-2_5G.pmthresholds.trunk.ms.farend.1day.ES

864 (seconds)

0-86400

MXP-MR-2_5G.pmthresholds.trunk.ms.farend.1day.SES

4 (seconds)

0-86400

MXP-MR-2_5G.pmthresholds.trunk.ms.farend.1day.UAS

10 (seconds)

0-86400

MXP-MR-2_5G.pmthresholds.trunk.ms.nearend.15min.BBE

21260 (count)

0-2212200

MXP-MR-2_5G.pmthresholds.trunk.ms.nearend.15min.EB

21260 (count)

0-2212200

MXP-MR-2_5G.pmthresholds.trunk.ms.nearend.15min.ES

87 (seconds)

0-900

MXP-MR-2_5G.pmthresholds.trunk.ms.nearend.15min.SES

1 (seconds)

0-900

MXP-MR-2_5G.pmthresholds.trunk.ms.nearend.15min.UAS

3 (seconds)

0-900

MXP-MR-2_5G.pmthresholds.trunk.ms.nearend.1day.BBE

212600 (count)

0-2212200

MXP-MR-2_5G.pmthresholds.trunk.ms.nearend.1day.EB

212600 (count)

0-212371200

MXP-MR-2_5G.pmthresholds.trunk.ms.nearend.1day.ES

864 (seconds)

0-86400

MXP-MR-2_5G.pmthresholds.trunk.ms.nearend.1day.SES

4 (seconds)

0-86400

MXP-MR-2_5G.pmthresholds.trunk.ms.nearend.1day.UAS

10 (seconds)

0-86400

MXP-MR-2_5G.pmthresholds.trunk.rs.nearend.15min.BBE

10000 (count)

0-2151900

MXP-MR-2_5G.pmthresholds.trunk.rs.nearend.15min.EB

10000 (count)

0-2151900

MXP-MR-2_5G.pmthresholds.trunk.rs.nearend.15min.ES

500 (seconds)

0-900

MXP-MR-2_5G.pmthresholds.trunk.rs.nearend.15min.SES

500 (seconds)

0-900

MXP-MR-2_5G.pmthresholds.trunk.rs.nearend.15min.UAS

3 (seconds)

0-900

MXP-MR-2_5G.pmthresholds.trunk.rs.nearend.1day.BBE

100000 (count)

0-206582400

MXP-MR-2_5G.pmthresholds.trunk.rs.nearend.1day.EB

100000 (count)

0-206582400

MXP-MR-2_5G.pmthresholds.trunk.rs.nearend.1day.ES

5000 (seconds)

0-86400

MXP-MR-2_5G.pmthresholds.trunk.rs.nearend.1day.SES

5000 (seconds)

0-86400

MXP-MR-2_5G.pmthresholds.trunk.rs.nearend.1day.UAS

10 (seconds)

0-86400


D.3.1.4  MXPP_MR_2.5G Card Default Settings

Table D-16 lists the MXPP_MR_2.5G card default settings.

Table D-16 MXPP_MR_2.5G Card Default Settings (ETSI) 

Default Name
Default Value
Default Domain

MXPP-MR-2_5G.config.client.AlsMode

Disabled

Disabled, Manual Restart, Manual Restart for Test

MXPP-MR-2_5G.config.client.AlsRecoveryPulseDuration

4.0 (seconds)

2.0, 2.1, 2.2 .. 100.0 when AlsMode is Disabled, Auto Restart, Manual Restart

80.0, 80.1, 80.2 .. 100.0 when AlsMode is Manual Restart for Test

MXPP-MR-2_5G.config.client.AlsRecoveryPulseInterval

100 (seconds)

60-300

MXPP-MR-2_5G.config.client.ppmPortAssignment

UNASSIGNED

UNASSIGNED, ONE_GE, FC1G ISL, FC2G ISL, FICON1G ISL, FICON2G ISL

MXPP-MR-2_5G.config.client.ppmSlotAssignment

UNASSIGNED

UNASSIGNED, PPM (1 Port)

MXPP-MR-2_5G.config.fc.distanceExtension.AutoadjustGFPBufferThreshold

TRUE

TRUE, FALSE

MXPP-MR-2_5G.config.fc.distanceExtension.AutoDetect

TRUE

TRUE, FALSE

MXPP-MR-2_5G.config.fc.distanceExtension.Enabled

TRUE

TRUE, FALSE

MXPP-MR-2_5G.config.fc.distanceExtension.NumCredits

32

2-256

MXPP-MR-2_5G.config.fc.distanceExtension.NumGFPBuffers

16

16, 32, 48 .. 1200

MXPP-MR-2_5G.config.fc.enhancedFibreChannelFicon.MaxFrameSize

2148

2148, 2152, 2156, 2160, 2164, 2168, 2172

MXPP-MR-2_5G.config.trunk.AINSSoakTime

08:00 (hours:mins)

00:00, 00:15, 00:30 .. 48:00

MXPP-MR-2_5G.config.trunk.AlsMode

Disabled

Disabled, Auto Restart, Manual Restart, Manual Restart for Test

MXPP-MR-2_5G.config.trunk.AlsRecoveryPulseDuration

4.0 (seconds)

2.0, 2.1, 2.2 .. 100.0 when AlsMode is Disabled, Auto Restart, Manual Restart

80.0, 80.1, 80.2 .. 100.0 when AlsMode is Manual Restart for Test

MXPP-MR-2_5G.config.trunk.AlsRecoveryPulseInterval

100 (seconds)

60-300

MXPP-MR-2_5G.config.trunk.SDBER

1E-7

1E-5, 1E-6, 1E-7, 1E-8, 1E-9

MXPP-MR-2_5G.config.trunk.SFBER

1E-4

1E-3, 1E-4, 1E-5

MXPP-MR-2_5G.opticalthresholds.client.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.alarm.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.alarm.LowRxPower

-21.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.alarm.LowTxPower

-8.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.warning.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.warning.15min.HighRxPower

2.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.warning.15min.HighTxPower

2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.warning.15min.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.warning.15min.LowTxPower

-7.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.client.warning.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.client.warning.1day.HighRxPower

2.5 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.warning.1day.HighTxPower

2.5 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.client.warning.1day.LowRxPower

-20.5 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.client.warning.1day.LowTxPower

-7.5 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.trunk.alarm.HighLaserBias

98.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.trunk.alarm.HighRxPower

-8.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.trunk.alarm.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.trunk.alarm.LowRxPower

-25.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.trunk.alarm.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.trunk.warning.15min.HighLaserBias

95.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.trunk.warning.15min.HighRxPower

-7.5 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.trunk.warning.15min.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.trunk.warning.15min.LowRxPower

-24.5 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.trunk.warning.15min.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.opticalthresholds.trunk.warning.1day.HighLaserBias

96.0 (%)

0.0, 0.1, 0.2 .. 100.0

MXPP-MR-2_5G.opticalthresholds.trunk.warning.1day.HighRxPower

-7.3 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.trunk.warning.1day.HighTxPower

30.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

MXPP-MR-2_5G.opticalthresholds.trunk.warning.1day.LowRxPower

-24.7 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

MXPP-MR-2_5G.opticalthresholds.trunk.warning.1day.LowTxPower

-40.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

MXPP-MR-2_5G.pmthresholds.trunk.ms.farend.15min.BBE

21260 (count)

0-2212200

MXPP-MR-2_5G.pmthresholds.trunk.ms.farend.15min.EB

21260 (count)

0-2212200

MXPP-MR-2_5G.pmthresholds.trunk.ms.farend.15min.ES

87 (seconds)

0-900

MXPP-MR-2_5G.pmthresholds.trunk.ms.farend.15min.SES

1 (seconds)

0-900

MXPP-MR-2_5G.pmthresholds.trunk.ms.farend.15min.UAS

3 (seconds)

0-900

MXPP-MR-2_5G.pmthresholds.trunk.ms.farend.1day.BBE

212600 (count)

0-2212200

MXPP-MR-2_5G.pmthresholds.trunk.ms.farend.1day.EB

212600 (count)

0-212371200

MXPP-MR-2_5G.pmthresholds.trunk.ms.farend.1day.ES

864 (seconds)

0-86400

MXPP-MR-2_5G.pmthresholds.trunk.ms.farend.1day.SES

4 (seconds)

0-86400

MXPP-MR-2_5G.pmthresholds.trunk.ms.farend.1day.UAS

10 (seconds)

0-86400

MXPP-MR-2_5G.pmthresholds.trunk.ms.nearend.15min.BBE

21260 (count)

0-2212200

MXPP-MR-2_5G.pmthresholds.trunk.ms.nearend.15min.EB

21260 (count)

0-2212200

MXPP-MR-2_5G.pmthresholds.trunk.ms.nearend.15min.ES

87 (seconds)

0-900

MXPP-MR-2_5G.pmthresholds.trunk.ms.nearend.15min.SES

1 (seconds)

0-900

MXPP-MR-2_5G.pmthresholds.trunk.ms.nearend.15min.UAS

3 (seconds)

0-900

MXPP-MR-2_5G.pmthresholds.trunk.ms.nearend.1day.BBE

212600 (count)

0-2212200

MXPP-MR-2_5G.pmthresholds.trunk.ms.nearend.1day.EB

212600 (count)

0-212371200

MXPP-MR-2_5G.pmthresholds.trunk.ms.nearend.1day.ES

864 (seconds)

0-86400

MXPP-MR-2_5G.pmthresholds.trunk.ms.nearend.1day.SES

4 (seconds)

0-86400

MXPP-MR-2_5G.pmthresholds.trunk.ms.nearend.1day.UAS

10 (seconds)

0-86400

MXPP-MR-2_5G.pmthresholds.trunk.rs.nearend.15min.BBE

10000 (count)

0-2151900

MXPP-MR-2_5G.pmthresholds.trunk.rs.nearend.15min.EB

10000 (count)

0-2151900

MXPP-MR-2_5G.pmthresholds.trunk.rs.nearend.15min.ES

500 (seconds)

0-900

MXPP-MR-2_5G.pmthresholds.trunk.rs.nearend.15min.SES

500 (seconds)

0-900

MXPP-MR-2_5G.pmthresholds.trunk.rs.nearend.15min.UAS

3 (seconds)

0-900

MXPP-MR-2_5G.pmthresholds.trunk.rs.nearend.1day.BBE

100000 (count)

0-206582400

MXPP-MR-2_5G.pmthresholds.trunk.rs.nearend.1day.EB

100000 (count)

0-206582400

MXPP-MR-2_5G.pmthresholds.trunk.rs.nearend.1day.ES

5000 (seconds)

0-86400

MXPP-MR-2_5G.pmthresholds.trunk.rs.nearend.1day.SES

5000 (seconds)

0-86400

MXPP-MR-2_5G.pmthresholds.trunk.rs.nearend.1day.UAS

10 (seconds)

0-86400


D.3.1.5  TXP_MR_10E Card Default Settings

Table D-17 lists the TXP_MR_10E card default settings.

Table D-17 TXP_MR_10E Card Default Settings (ETSI) 

Default Name
Default Value
Default Domain

TXP-MR-10E.config.client.AINSSoakTime

08:00 (hours:mins)

00:00, 00:15, 00:30 .. 48:00

TXP-MR-10E.config.client.AisSquelchMode

Squelch

Ais, Squelch

TXP-MR-10E.config.client.AlsMode

Disabled

Disabled, Auto Restart, Manual Restart, Manual Restart for Test

TXP-MR-10E.config.client.AlsRecoveryPulseDuration

2.0 (seconds)

2.0, 2.1, 2.2 .. 100.0 when AlsMode is Disabled, Auto Restart, Manual Restart

80.0, 80.1, 80.2 .. 100.0 when AlsMode is Manual Restart for Test

TXP-MR-10E.config.client.AlsRecoveryPulseInterval

100 (seconds)

100-2000

TXP-MR-10E.config.client.ppmPortAssignment

UNASSIGNED

UNASSIGNED, SDH, 10G Ethernet, 10G Fiber Channel

TXP-MR-10E.config.client.ppmSlotAssignment

UNASSIGNED

UNASSIGNED, PPM (1 Port)

TXP-MR-10E.config.client.SDBER

1E-7

1E-5, 1E-6, 1E-7, 1E-8, 1E-9

TXP-MR-10E.config.client.SendDoNotUse

FALSE

TRUE, FALSE

TXP-MR-10E.config.client.SFBER

1E-4

1E-3, 1E-4, 1E-5

TXP-MR-10E.config.client.SyncMsgIn

TRUE

FALSE, TRUE

TXP-MR-10E.config.client.TerminationMode

Transparent

Transparent, Regeneration Section, Multiplex Section when ppmPortAssignment is UNASSIGNED, SONET

Transparent when ppmPortAssignment is 10G Ethernet, 10G Fiber Channel

TXP-MR-10E.config.trunk.AINSSoakTime

08:00 (hours:mins)

00:00, 00:15, 00:30 .. 48:00

TXP-MR-10E.config.trunk.AlsMode

Disabled

Disabled, Auto Restart, Manual Restart, Manual Restart for Test

TXP-MR-10E.config.trunk.AlsRecoveryPulseDuration

100.0 (seconds)

6.0, 6.1, 6.2 .. 200.0 when AlsMode is Disabled, Auto Restart, Manual Restart

80.0, 80.1, 80.2 .. 100.0 when AlsMode is Manual Restart for Test

TXP-MR-10E.config.trunk.AlsRecoveryPulseInterval

300 (seconds)

200-2000

TXP-MR-10E.config.trunk.SDBER

1E-7

1E-5, 1E-6, 1E-7, 1E-8, 1E-9

TXP-MR-10E.config.trunk.SFBER

1E-4

1E-3, 1E-4, 1E-5

TXP-MR-10E.opticalthresholds.client.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.alarm.HighRxPower

2.0 (dBm)

-17.0, -16.9, -16.8 .. 30.0

TXP-MR-10E.opticalthresholds.client.alarm.HighTxPower

2.0 (dBm)

-9.0, -8.9, -8.8 .. 30.0

TXP-MR-10E.opticalthresholds.client.alarm.LowRxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. 2.0

TXP-MR-10E.opticalthresholds.client.alarm.LowTxPower

-9.0 (dBm)

-40.0, -39.9, -39.8 .. 2.0

TXP-MR-10E.opticalthresholds.client.warning.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.warning.15min.HighRxPower

1.0 (dBm)

-16.0, -15.9, -15.8 .. 30.0

TXP-MR-10E.opticalthresholds.client.warning.15min.HighTxPower

1.0 (dBm)

-8.0, -7.9, -7.8 .. 30.0

TXP-MR-10E.opticalthresholds.client.warning.15min.LowRxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. 1.0

TXP-MR-10E.opticalthresholds.client.warning.15min.LowTxPower

-8.0 (dBm)

-40.0, -39.9, -39.8 .. 1.0

TXP-MR-10E.opticalthresholds.client.warning.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.client.warning.1day.HighRxPower

1.5 (dBm)

-16.5, -16.4, -16.3 .. 30.0

TXP-MR-10E.opticalthresholds.client.warning.1day.HighTxPower

1.5 (dBm)

-8.5, -8.4, -8.3 .. 30.0

TXP-MR-10E.opticalthresholds.client.warning.1day.LowRxPower

-16.5 (dBm)

-40.0, -39.9, -39.8 .. 1.5

TXP-MR-10E.opticalthresholds.client.warning.1day.LowTxPower

-8.5 (dBm)

-40.0, -39.9, -39.8 .. 1.5

TXP-MR-10E.opticalthresholds.trunk.alarm.HighLaserBias

98.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.trunk.alarm.HighRxPower

-8.0 (dBm)

-25.0, -24.9, -24.8 .. 30.0

TXP-MR-10E.opticalthresholds.trunk.alarm.HighTxPower

8.0 (dBm)

1.0, 1.1, 1.2 .. 30.0

TXP-MR-10E.opticalthresholds.trunk.alarm.LowRxPower

-25.0 (dBm)

-40.0, -39.9, -39.8 .. -8.0

TXP-MR-10E.opticalthresholds.trunk.alarm.LowTxPower

1.0 (dBm)

-40.0, -39.9, -39.8 .. 8.0

TXP-MR-10E.opticalthresholds.trunk.warning.15min.HighLaserBias

95.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.trunk.warning.15min.HighRxPower

-7.5 (dBm)

-24.5, -24.4, -24.3 .. 30.0

TXP-MR-10E.opticalthresholds.trunk.warning.15min.HighTxPower

7.0 (dBm)

2.0, 2.1, 2.2 .. 30.0

TXP-MR-10E.opticalthresholds.trunk.warning.15min.LowRxPower

-24.5 (dBm)

-40.0, -39.9, -39.8 .. -7.5

TXP-MR-10E.opticalthresholds.trunk.warning.15min.LowTxPower

2.0 (dBm)

-40.0, -39.9, -39.8 .. 7.0

TXP-MR-10E.opticalthresholds.trunk.warning.1day.HighLaserBias

96.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10E.opticalthresholds.trunk.warning.1day.HighRxPower

-7.3 (dBm)

-24.7, -24.6, -24.5 .. 30.0

TXP-MR-10E.opticalthresholds.trunk.warning.1day.HighTxPower

7.0 (dBm)

2.0, 2.1, 2.2 .. 30.0

TXP-MR-10E.opticalthresholds.trunk.warning.1day.LowRxPower

-24.7 (dBm)

-40.0, -39.9, -39.8 .. -7.3

TXP-MR-10E.opticalthresholds.trunk.warning.1day.LowTxPower

2.0 (dBm)

-40.0, -39.9, -39.8 .. 7.0

TXP-MR-10E.otn.fecthresholds.enhanced.15min.BitErrorsCorrected

903330 (count)

0-9033621811200

TXP-MR-10E.otn.fecthresholds.enhanced.15min.UncorrectableWords

5 (count)

0-4724697600

TXP-MR-10E.otn.fecthresholds.enhanced.1day.BitErrorsCorrected

86719680 (count)

0-867227693875200

TXP-MR-10E.otn.fecthresholds.enhanced.1day.UncorrectableWords

480 (count)

0-453570969600

TXP-MR-10E.otn.fecthresholds.standard.15min.BitErrorsCorrected

903330 (count)

0-9033621811200

TXP-MR-10E.otn.fecthresholds.standard.15min.UncorrectableWords

5 (count)

0-4724697600

TXP-MR-10E.otn.fecthresholds.standard.1day.BitErrorsCorrected

86719680 (count)

0-867227693875200

TXP-MR-10E.otn.fecthresholds.standard.1day.UncorrectableWords

480 (count)

0-453570969600

TXP-MR-10E.otn.g709thresholds.pm.farend.15min.BBE

85040 (count)

0-8850600

TXP-MR-10E.otn.g709thresholds.pm.farend.15min.ES

87 (seconds)

0-900

TXP-MR-10E.otn.g709thresholds.pm.farend.15min.FC

10 (count)

0-72

TXP-MR-10E.otn.g709thresholds.pm.farend.15min.SES

1 (seconds)

0-900

TXP-MR-10E.otn.g709thresholds.pm.farend.15min.UAS

3 (seconds)

0-900

TXP-MR-10E.otn.g709thresholds.pm.farend.1day.BBE

850400 (count)

0-849657600

TXP-MR-10E.otn.g709thresholds.pm.farend.1day.ES

864 (seconds)

0-86400

TXP-MR-10E.otn.g709thresholds.pm.farend.1day.FC

40 (count)

0-6912

TXP-MR-10E.otn.g709thresholds.pm.farend.1day.SES

4 (seconds)

0-86400

TXP-MR-10E.otn.g709thresholds.pm.farend.1day.UAS

10 (seconds)

0-86400

TXP-MR-10E.otn.g709thresholds.pm.nearend.15min.BBE

85040 (count)

0-8850600

TXP-MR-10E.otn.g709thresholds.pm.nearend.15min.ES

87 (seconds)

0-900

TXP-MR-10E.otn.g709thresholds.pm.nearend.15min.FC

10 (count)

0-72

TXP-MR-10E.otn.g709thresholds.pm.nearend.15min.SES

1 (seconds)

0-900

TXP-MR-10E.otn.g709thresholds.pm.nearend.15min.UAS

3 (seconds)

0-900

TXP-MR-10E.otn.g709thresholds.pm.nearend.1day.BBE

850400 (count)

0-849657600

TXP-MR-10E.otn.g709thresholds.pm.nearend.1day.ES

864 (seconds)

0-86400

TXP-MR-10E.otn.g709thresholds.pm.nearend.1day.FC

40 (count)

0-6912

TXP-MR-10E.otn.g709thresholds.pm.nearend.1day.SES

4 (seconds)

0-86400

TXP-MR-10E.otn.g709thresholds.pm.nearend.1day.UAS

10 (seconds)

0-86400

TXP-MR-10E.otn.g709thresholds.sm.farend.15min.BBE

10000 (count)

0-8850600

TXP-MR-10E.otn.g709thresholds.sm.farend.15min.ES

500 (seconds)

0-900

TXP-MR-10E.otn.g709thresholds.sm.farend.15min.FC

10 (count)

0-72

TXP-MR-10E.otn.g709thresholds.sm.farend.15min.SES

500 (seconds)

0-900

TXP-MR-10E.otn.g709thresholds.sm.farend.15min.UAS

500 (seconds)

0-900

TXP-MR-10E.otn.g709thresholds.sm.farend.1day.BBE

100000 (count)

0-849657600

TXP-MR-10E.otn.g709thresholds.sm.farend.1day.ES

5000 (seconds)

0-86400

TXP-MR-10E.otn.g709thresholds.sm.farend.1day.FC

40 (count)

0-6912

TXP-MR-10E.otn.g709thresholds.sm.farend.1day.SES

5000 (seconds)

0-86400

TXP-MR-10E.otn.g709thresholds.sm.farend.1day.UAS

5000 (seconds)

0-86400

TXP-MR-10E.otn.g709thresholds.sm.nearend.15min.BBE

10000 (count)

0-8850600

TXP-MR-10E.otn.g709thresholds.sm.nearend.15min.ES

500 (seconds)

0-900

TXP-MR-10E.otn.g709thresholds.sm.nearend.15min.FC

10 (count)

0-72

TXP-MR-10E.otn.g709thresholds.sm.nearend.15min.SES

500 (seconds)

0-900

TXP-MR-10E.otn.g709thresholds.sm.nearend.15min.UAS

500 (seconds)

0-900

TXP-MR-10E.otn.g709thresholds.sm.nearend.1day.BBE

100000 (count)

0-849657600

TXP-MR-10E.otn.g709thresholds.sm.nearend.1day.ES

5000 (seconds)

0-86400

TXP-MR-10E.otn.g709thresholds.sm.nearend.1day.FC

40 (count)

0-6912

TXP-MR-10E.otn.g709thresholds.sm.nearend.1day.SES

5000 (seconds)

0-86400

TXP-MR-10E.otn.g709thresholds.sm.nearend.1day.UAS

5000 (seconds)

0-86400

TXP-MR-10E.otn.otnLines.AsynchSynchMapping

Synch Mapping

Asynch mapping, Synch Mapping

TXP-MR-10E.otn.otnLines.FEC

Standard

Disable, Standard, Enhanced when G709OTN is Enable

Disable when G709OTN is Disable

TXP-MR-10E.otn.otnLines.G709OTN

Enable

Disable, Enable

TXP-MR-10E.otn.otnLines.SDBER

1E-7

1E-5, 1E-6, 1E-7, 1E-8, 1E-9

TXP-MR-10E.pmthresholds.client.ms.farend.15min.BBE

85040 (count)

0-8850600

TXP-MR-10E.pmthresholds.client.ms.farend.15min.EB

85040 (count)

0-8850600

TXP-MR-10E.pmthresholds.client.ms.farend.15min.ES

87 (seconds)

0-900

TXP-MR-10E.pmthresholds.client.ms.farend.15min.SES

1 (seconds)

0-900

TXP-MR-10E.pmthresholds.client.ms.farend.15min.UAS

3 (seconds)

0-900

TXP-MR-10E.pmthresholds.client.ms.farend.1day.BBE

850400 (count)

0-849657600

TXP-MR-10E.pmthresholds.client.ms.farend.1day.EB

850400 (count)

0-849657600

TXP-MR-10E.pmthresholds.client.ms.farend.1day.ES

864 (seconds)

0-86400

TXP-MR-10E.pmthresholds.client.ms.farend.1day.SES

4 (seconds)

0-86400

TXP-MR-10E.pmthresholds.client.ms.farend.1day.UAS

10 (seconds)

0-86400

TXP-MR-10E.pmthresholds.client.ms.nearend.15min.BBE

85040 (count)

0-8850600

TXP-MR-10E.pmthresholds.client.ms.nearend.15min.EB

85040 (count)

0-8850600

TXP-MR-10E.pmthresholds.client.ms.nearend.15min.ES

87 (seconds)

0-900

TXP-MR-10E.pmthresholds.client.ms.nearend.15min.SES

1 (seconds)

0-900

TXP-MR-10E.pmthresholds.client.ms.nearend.15min.UAS

3 (seconds)

0-900

TXP-MR-10E.pmthresholds.client.ms.nearend.1day.BBE

850400 (count)

0-849657600

TXP-MR-10E.pmthresholds.client.ms.nearend.1day.EB

850400 (count)

0-849657600

TXP-MR-10E.pmthresholds.client.ms.nearend.1day.ES

864 (seconds)

0-86400

TXP-MR-10E.pmthresholds.client.ms.nearend.1day.SES

4 (seconds)

0-86400

TXP-MR-10E.pmthresholds.client.ms.nearend.1day.UAS

10 (seconds)

0-86400

TXP-MR-10E.pmthresholds.client.rs.nearend.15min.BBE

10000 (count)

0-8850600

TXP-MR-10E.pmthresholds.client.rs.nearend.15min.EB

10000 (count)

0-7967700

TXP-MR-10E.pmthresholds.client.rs.nearend.15min.ES

500 (seconds)

0-900

TXP-MR-10E.pmthresholds.client.rs.nearend.15min.SES

500 (seconds)

0-900

TXP-MR-10E.pmthresholds.client.rs.nearend.15min.UAS

3 (seconds)

0-900

TXP-MR-10E.pmthresholds.client.rs.nearend.1day.BBE

100000 (count)

0-849657600

TXP-MR-10E.pmthresholds.client.rs.nearend.1day.EB

100000 (count)

0-764899200

TXP-MR-10E.pmthresholds.client.rs.nearend.1day.ES

5000 (seconds)

0-86400

TXP-MR-10E.pmthresholds.client.rs.nearend.1day.SES

5000 (seconds)

0-86400

TXP-MR-10E.pmthresholds.client.rs.nearend.1day.UAS

10 (seconds)

0-86400

TXP-MR-10E.pmthresholds.trunk.ms.farend.15min.BBE

85040 (count)

0-8850600

TXP-MR-10E.pmthresholds.trunk.ms.farend.15min.EB

85040 (count)

0-8850600

TXP-MR-10E.pmthresholds.trunk.ms.farend.15min.ES

87 (seconds)

0-900

TXP-MR-10E.pmthresholds.trunk.ms.farend.15min.SES

1 (seconds)

0-900

TXP-MR-10E.pmthresholds.trunk.ms.farend.15min.UAS

3 (seconds)

0-900

TXP-MR-10E.pmthresholds.trunk.ms.farend.1day.BBE

850400 (count)

0-849657600

TXP-MR-10E.pmthresholds.trunk.ms.farend.1day.EB

850400 (count)

0-849657600

TXP-MR-10E.pmthresholds.trunk.ms.farend.1day.ES

864 (seconds)

0-86400

TXP-MR-10E.pmthresholds.trunk.ms.farend.1day.SES

4 (seconds)

0-86400

TXP-MR-10E.pmthresholds.trunk.ms.farend.1day.UAS

10 (seconds)

0-86400

TXP-MR-10E.pmthresholds.trunk.ms.nearend.15min.BBE

85040 (count)

0-8850600

TXP-MR-10E.pmthresholds.trunk.ms.nearend.15min.EB

85040 (count)

0-8850600

TXP-MR-10E.pmthresholds.trunk.ms.nearend.15min.ES

87 (seconds)

0-900

TXP-MR-10E.pmthresholds.trunk.ms.nearend.15min.SES

1 (seconds)

0-900

TXP-MR-10E.pmthresholds.trunk.ms.nearend.15min.UAS

3 (seconds)

0-900

TXP-MR-10E.pmthresholds.trunk.ms.nearend.1day.BBE

850400 (count)

0-849657600

TXP-MR-10E.pmthresholds.trunk.ms.nearend.1day.EB

850400 (count)

0-849657600

TXP-MR-10E.pmthresholds.trunk.ms.nearend.1day.ES

864 (seconds)

0-86400

TXP-MR-10E.pmthresholds.trunk.ms.nearend.1day.SES

4 (seconds)

0-86400

TXP-MR-10E.pmthresholds.trunk.ms.nearend.1day.UAS

10 (seconds)

0-86400

TXP-MR-10E.pmthresholds.trunk.rs.nearend.15min.BBE

10000 (count)

0-8850600

TXP-MR-10E.pmthresholds.trunk.rs.nearend.15min.EB

10000 (count)

0-7967700

TXP-MR-10E.pmthresholds.trunk.rs.nearend.15min.ES

500 (seconds)

0-900

TXP-MR-10E.pmthresholds.trunk.rs.nearend.15min.SES

500 (seconds)

0-900

TXP-MR-10E.pmthresholds.trunk.rs.nearend.15min.UAS

3 (seconds)

0-900

TXP-MR-10E.pmthresholds.trunk.rs.nearend.1day.BBE

100000 (count)

0-849657600

TXP-MR-10E.pmthresholds.trunk.rs.nearend.1day.EB

100000 (count)

0-764899200

TXP-MR-10E.pmthresholds.trunk.rs.nearend.1day.ES

5000 (seconds)

0-86400

TXP-MR-10E.pmthresholds.trunk.rs.nearend.1day.SES

5000 (seconds)

0-86400

TXP-MR-10E.pmthresholds.trunk.rs.nearend.1day.UAS

10 (seconds)

0-86400


D.3.1.6  TXP_MR_10G Card Default Settings

Table D-18 lists the TXP_MR_10G card default settings.

Table D-18 TXP_MR_10G Card Default Settings (ETSI) 

Default Name
Default Value
Default Domain

TXP-MR-10G.config.client.AINSSoakTime

08:00 (hours:mins)

00:00, 00:15, 00:30 .. 48:00

TXP-MR-10G.config.client.AlsMode

Disabled

Disabled, Auto Restart, Manual Restart, Manual Restart for Test

TXP-MR-10G.config.client.AlsRecoveryPulseDuration

4.0 (seconds)

2.0, 2.1, 2.2 .. 100.0 when AlsMode is Disabled, Auto Restart, Manual Restart

80.0, 80.1, 80.2 .. 100.0 when AlsMode is Manual Restart for Test

TXP-MR-10G.config.client.AlsRecoveryPulseInterval

100 (seconds)

100-300

TXP-MR-10G.config.client.mrPortAssignment

UNASSIGNED

UNASSIGNED, SDH, 10G Ethernet

TXP-MR-10G.config.client.SDBER

1E-7

1E-5, 1E-6, 1E-7, 1E-8, 1E-9

TXP-MR-10G.config.client.SFBER

1E-4

1E-3, 1E-4, 1E-5

TXP-MR-10G.config.client.TerminationMode

Transparent

Transparent, Regeneration Section, Multiplex Section when mrPortAssignment is UNASSIGNED, SDH

Transparent when mrPortAssignment is 10G Ethernet

TXP-MR-10G.config.trunk.AINSSoakTime

08:00 (hours:mins)

00:00, 00:15, 00:30 .. 48:00

TXP-MR-10G.config.trunk.AlsMode

Disabled

Disabled, Auto Restart, Manual Restart, Manual Restart for Test

TXP-MR-10G.config.trunk.AlsRecoveryPulseDuration

4.0 (seconds)

2.0, 2.1, 2.2 .. 100.0 when AlsMode is Disabled, Auto Restart, Manual Restart

80.0, 80.1, 80.2 .. 100.0 when AlsMode is Manual Restart for Test

TXP-MR-10G.config.trunk.AlsRecoveryPulseInterval

100 (seconds)

60-300

TXP-MR-10G.config.trunk.SDBER

1E-7

1E-5, 1E-6, 1E-7, 1E-8, 1E-9

TXP-MR-10G.config.trunk.SFBER

1E-4

1E-3, 1E-4, 1E-5

TXP-MR-10G.opticalthresholds.client.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10G.opticalthresholds.client.alarm.HighRxPower

2.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10G.opticalthresholds.client.alarm.HighTxPower

2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10G.opticalthresholds.client.alarm.LowRxPower

-17.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10G.opticalthresholds.client.alarm.LowTxPower

-9.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10G.opticalthresholds.client.warning.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10G.opticalthresholds.client.warning.15min.HighRxPower

1.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10G.opticalthresholds.client.warning.15min.HighTxPower

1.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10G.opticalthresholds.client.warning.15min.LowRxPower

-16.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10G.opticalthresholds.client.warning.15min.LowTxPower

-8.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10G.opticalthresholds.client.warning.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10G.opticalthresholds.client.warning.1day.HighRxPower

1.5 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10G.opticalthresholds.client.warning.1day.HighTxPower

1.5 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10G.opticalthresholds.client.warning.1day.LowRxPower

-16.5 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10G.opticalthresholds.client.warning.1day.LowTxPower

-8.5 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10G.opticalthresholds.trunk.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10G.opticalthresholds.trunk.alarm.HighRxPower

-8.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10G.opticalthresholds.trunk.alarm.HighTxPower

4.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10G.opticalthresholds.trunk.alarm.LowRxPower

-25.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10G.opticalthresholds.trunk.alarm.LowTxPower

2.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10G.opticalthresholds.trunk.warning.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10G.opticalthresholds.trunk.warning.15min.HighRxPower

-7.5 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10G.opticalthresholds.trunk.warning.15min.HighTxPower

3.5 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10G.opticalthresholds.trunk.warning.15min.LowRxPower

-24.5 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10G.opticalthresholds.trunk.warning.15min.LowTxPower

2.5 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10G.opticalthresholds.trunk.warning.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-10G.opticalthresholds.trunk.warning.1day.HighRxPower

-7.3 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-10G.opticalthresholds.trunk.warning.1day.HighTxPower

3.7 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-10G.opticalthresholds.trunk.warning.1day.LowRxPower

-24.7 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-10G.opticalthresholds.trunk.warning.1day.LowTxPower

2.3 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-10G.otn.fecthresholds.standard.15min.BitErrorsCorrected

903330 (count)

0-9033621811200

TXP-MR-10G.otn.fecthresholds.standard.15min.UncorrectableWords

5 (count)

0-4724697600

TXP-MR-10G.otn.fecthresholds.standard.1day.BitErrorsCorrected

86719680 (count)

0-867227693875200

TXP-MR-10G.otn.fecthresholds.standard.1day.UncorrectableWords

480 (count)

0-453570969600

TXP-MR-10G.otn.g709thresholds.pm.farend.15min.BBE

85040 (count)

0-8850600

TXP-MR-10G.otn.g709thresholds.pm.farend.15min.ES

87 (seconds)

0-900

TXP-MR-10G.otn.g709thresholds.pm.farend.15min.FC

10 (count)

0-72

TXP-MR-10G.otn.g709thresholds.pm.farend.15min.SES

1 (seconds)

0-900

TXP-MR-10G.otn.g709thresholds.pm.farend.15min.UAS

3 (seconds)

0-900

TXP-MR-10G.otn.g709thresholds.pm.farend.1day.BBE

850400 (count)

0-849657600

TXP-MR-10G.otn.g709thresholds.pm.farend.1day.ES

864 (seconds)

0-86400

TXP-MR-10G.otn.g709thresholds.pm.farend.1day.FC

40 (count)

0-6912

TXP-MR-10G.otn.g709thresholds.pm.farend.1day.SES

4 (seconds)

0-86400

TXP-MR-10G.otn.g709thresholds.pm.farend.1day.UAS

10 (seconds)

0-86400

TXP-MR-10G.otn.g709thresholds.pm.nearend.15min.BBE

85040 (count)

0-8850600

TXP-MR-10G.otn.g709thresholds.pm.nearend.15min.ES

87 (seconds)

0-900

TXP-MR-10G.otn.g709thresholds.pm.nearend.15min.FC

10 (count)

0-72

TXP-MR-10G.otn.g709thresholds.pm.nearend.15min.SES

1 (seconds)

0-900

TXP-MR-10G.otn.g709thresholds.pm.nearend.15min.UAS

3 (seconds)

0-900

TXP-MR-10G.otn.g709thresholds.pm.nearend.1day.BBE

850400 (count)

0-849657600

TXP-MR-10G.otn.g709thresholds.pm.nearend.1day.ES

864 (seconds)

0-86400

TXP-MR-10G.otn.g709thresholds.pm.nearend.1day.FC

40 (count)

0-6912

TXP-MR-10G.otn.g709thresholds.pm.nearend.1day.SES

4 (seconds)

0-86400

TXP-MR-10G.otn.g709thresholds.pm.nearend.1day.UAS

10 (seconds)

0-86400

TXP-MR-10G.otn.g709thresholds.sm.farend.15min.BBE

10000 (count)

0-8850600

TXP-MR-10G.otn.g709thresholds.sm.farend.15min.ES

500 (seconds)

0-900

TXP-MR-10G.otn.g709thresholds.sm.farend.15min.FC

10 (count)

0-72

TXP-MR-10G.otn.g709thresholds.sm.farend.15min.SES

500 (seconds)

0-900

TXP-MR-10G.otn.g709thresholds.sm.farend.15min.UAS

500 (seconds)

0-900

TXP-MR-10G.otn.g709thresholds.sm.farend.1day.BBE

100000 (count)

0-849657600

TXP-MR-10G.otn.g709thresholds.sm.farend.1day.ES

5000 (seconds)

0-86400

TXP-MR-10G.otn.g709thresholds.sm.farend.1day.FC

40 (count)

0-6912

TXP-MR-10G.otn.g709thresholds.sm.farend.1day.SES

5000 (seconds)

0-86400

TXP-MR-10G.otn.g709thresholds.sm.farend.1day.UAS

5000 (seconds)

0-86400

TXP-MR-10G.otn.g709thresholds.sm.nearend.15min.BBE

10000 (count)

0-8850600

TXP-MR-10G.otn.g709thresholds.sm.nearend.15min.ES

500 (seconds)

0-900

TXP-MR-10G.otn.g709thresholds.sm.nearend.15min.FC

10 (count)

0-72

TXP-MR-10G.otn.g709thresholds.sm.nearend.15min.SES

500 (seconds)

0-900

TXP-MR-10G.otn.g709thresholds.sm.nearend.15min.UAS

500 (seconds)

0-900

TXP-MR-10G.otn.g709thresholds.sm.nearend.1day.BBE

100000 (count)

0-849657600

TXP-MR-10G.otn.g709thresholds.sm.nearend.1day.ES

5000 (seconds)

0-86400

TXP-MR-10G.otn.g709thresholds.sm.nearend.1day.FC

40 (count)

0-6912

TXP-MR-10G.otn.g709thresholds.sm.nearend.1day.SES

5000 (seconds)

0-86400

TXP-MR-10G.otn.g709thresholds.sm.nearend.1day.UAS

5000 (seconds)

0-86400

TXP-MR-10G.otn.otnLines.FEC

Enable

Disable, Enable when G709OTN is Enable

Disable when G709OTN is Disable

TXP-MR-10G.otn.otnLines.G709OTN

Enable

Disable, Enable

TXP-MR-10G.otn.otnLines.SDBER

1E-7

1E-5, 1E-6, 1E-7, 1E-8, 1E-9

TXP-MR-10G.pmthresholds.client.ms.farend.15min.BBE

85040 (count)

0-8850600

TXP-MR-10G.pmthresholds.client.ms.farend.15min.EB

85040 (count)

0-8850600

TXP-MR-10G.pmthresholds.client.ms.farend.15min.ES

87 (seconds)

0-900

TXP-MR-10G.pmthresholds.client.ms.farend.15min.SES

1 (seconds)

0-900

TXP-MR-10G.pmthresholds.client.ms.farend.15min.UAS

3 (seconds)

0-900

TXP-MR-10G.pmthresholds.client.ms.farend.1day.BBE

850400 (count)

0-849657600

TXP-MR-10G.pmthresholds.client.ms.farend.1day.EB

850400 (count)

0-849657600

TXP-MR-10G.pmthresholds.client.ms.farend.1day.ES

864 (seconds)

0-86400

TXP-MR-10G.pmthresholds.client.ms.farend.1day.SES

4 (seconds)

0-86400

TXP-MR-10G.pmthresholds.client.ms.farend.1day.UAS

10 (seconds)

0-86400

TXP-MR-10G.pmthresholds.client.ms.nearend.15min.BBE

85040 (count)

0-8850600

TXP-MR-10G.pmthresholds.client.ms.nearend.15min.EB

85040 (count)

0-8850600

TXP-MR-10G.pmthresholds.client.ms.nearend.15min.ES

87 (seconds)

0-900

TXP-MR-10G.pmthresholds.client.ms.nearend.15min.SES

1 (seconds)

0-900

TXP-MR-10G.pmthresholds.client.ms.nearend.15min.UAS

3 (seconds)

0-900

TXP-MR-10G.pmthresholds.client.ms.nearend.1day.BBE

850400 (count)

0-849657600

TXP-MR-10G.pmthresholds.client.ms.nearend.1day.EB

850400 (count)

0-849657600

TXP-MR-10G.pmthresholds.client.ms.nearend.1day.ES

864 (seconds)

0-86400

TXP-MR-10G.pmthresholds.client.ms.nearend.1day.SES

4 (seconds)

0-86400

TXP-MR-10G.pmthresholds.client.ms.nearend.1day.UAS

10 (seconds)

0-86400

TXP-MR-10G.pmthresholds.client.rs.nearend.15min.BBE

10000 (count)

0-8850600

TXP-MR-10G.pmthresholds.client.rs.nearend.15min.EB

10000 (count)

0-7967700

TXP-MR-10G.pmthresholds.client.rs.nearend.15min.ES

500 (seconds)

0-900

TXP-MR-10G.pmthresholds.client.rs.nearend.15min.SES

500 (seconds)

0-900

TXP-MR-10G.pmthresholds.client.rs.nearend.15min.UAS

3 (seconds)

0-900

TXP-MR-10G.pmthresholds.client.rs.nearend.1day.BBE

100000 (count)

0-849657600

TXP-MR-10G.pmthresholds.client.rs.nearend.1day.EB

100000 (count)

0-764899200

TXP-MR-10G.pmthresholds.client.rs.nearend.1day.ES

5000 (seconds)

0-86400

TXP-MR-10G.pmthresholds.client.rs.nearend.1day.SES

5000 (seconds)

0-86400

TXP-MR-10G.pmthresholds.client.rs.nearend.1day.UAS

10 (seconds)

0-86400

TXP-MR-10G.pmthresholds.trunk.ms.farend.15min.BBE

85040 (count)

0-8850600

TXP-MR-10G.pmthresholds.trunk.ms.farend.15min.EB

85040 (count)

0-8850600

TXP-MR-10G.pmthresholds.trunk.ms.farend.15min.ES

87 (seconds)

0-900

TXP-MR-10G.pmthresholds.trunk.ms.farend.15min.SES

1 (seconds)

0-900

TXP-MR-10G.pmthresholds.trunk.ms.farend.15min.UAS

3 (seconds)

0-900

TXP-MR-10G.pmthresholds.trunk.ms.farend.1day.BBE

850400 (count)

0-849657600

TXP-MR-10G.pmthresholds.trunk.ms.farend.1day.EB

850400 (count)

0-849657600

TXP-MR-10G.pmthresholds.trunk.ms.farend.1day.ES

864 (seconds)

0-86400

TXP-MR-10G.pmthresholds.trunk.ms.farend.1day.SES

4 (seconds)

0-86400

TXP-MR-10G.pmthresholds.trunk.ms.farend.1day.UAS

10 (seconds)

0-86400

TXP-MR-10G.pmthresholds.trunk.ms.nearend.15min.BBE

85040 (count)

0-8850600

TXP-MR-10G.pmthresholds.trunk.ms.nearend.15min.EB

85040 (count)

0-8850600

TXP-MR-10G.pmthresholds.trunk.ms.nearend.15min.ES

87 (seconds)

0-900

TXP-MR-10G.pmthresholds.trunk.ms.nearend.15min.SES

1 (seconds)

0-900

TXP-MR-10G.pmthresholds.trunk.ms.nearend.15min.UAS

3 (seconds)

0-900

TXP-MR-10G.pmthresholds.trunk.ms.nearend.1day.BBE

850400 (count)

0-849657600

TXP-MR-10G.pmthresholds.trunk.ms.nearend.1day.EB

850400 (count)

0-849657600

TXP-MR-10G.pmthresholds.trunk.ms.nearend.1day.ES

864 (seconds)

0-86400

TXP-MR-10G.pmthresholds.trunk.ms.nearend.1day.SES

4 (seconds)

0-86400

TXP-MR-10G.pmthresholds.trunk.ms.nearend.1day.UAS

10 (seconds)

0-86400

TXP-MR-10G.pmthresholds.trunk.rs.nearend.15min.BBE

10000 (count)

0-8850600

TXP-MR-10G.pmthresholds.trunk.rs.nearend.15min.EB

10000 (count)

0-7967700

TXP-MR-10G.pmthresholds.trunk.rs.nearend.15min.ES

500 (seconds)

0-900

TXP-MR-10G.pmthresholds.trunk.rs.nearend.15min.SES

500 (seconds)

0-900

TXP-MR-10G.pmthresholds.trunk.rs.nearend.15min.UAS

3 (seconds)

0-900

TXP-MR-10G.pmthresholds.trunk.rs.nearend.1day.BBE

100000 (count)

0-849657600

TXP-MR-10G.pmthresholds.trunk.rs.nearend.1day.EB

100000 (count)

0-764899200

TXP-MR-10G.pmthresholds.trunk.rs.nearend.1day.ES

5000 (seconds)

0-86400

TXP-MR-10G.pmthresholds.trunk.rs.nearend.1day.SES

5000 (seconds)

0-86400

TXP-MR-10G.pmthresholds.trunk.rs.nearend.1day.UAS

10 (seconds)

0-86400


D.3.1.7  TXP_MR_2.5G Card Default Settings

Table D-19 lists the TXP_MR_2.5G card default settings.

Table D-19 TXP_MR_2.5G Card Default Settings (ETSI) 

Default Name
Default Value
Default Domain

TXP-MR-2_5G.config.client.AINSSoakTime

08:00 (hours:mins)

00:00, 00:15, 00:30 .. 48:00

TXP-MR-2_5G.config.client.AlsMode

Disabled

Disabled, Auto Restart, Manual Restart, Manual Restart for Test

TXP-MR-2_5G.config.client.AlsRecoveryPulseDuration

40.0 (seconds)

2.0, 2.1, 2.2 .. 100.0 when AlsMode is Disabled, Auto Restart, Manual Restart

80.0, 80.1, 80.2 .. 100.0 when AlsMode is Manual Restart for Test

TXP-MR-2_5G.config.client.AlsRecoveryPulseInterval

100 (seconds)

60-300

TXP-MR-2_5G.config.client.ppmPortAssignment

UNASSIGNED

UNASSIGNED, STM1_PORT, STM4_PORT, STM16_PORT, ONE_GE_PORT, ESCON_PORT, DV6000_PORT, SDI_D1_VIDEO_PORT, HDTV_PORT, PASS_THRU_PORT, ETR_CLO_PORT, ISC compat, FC1G_PORT, FC2G_PORT, FICON1G_PORT, FICON2G_PORT, ISC peer

TXP-MR-2_5G.config.client.ppmSlotAssignment

UNASSIGNED

UNASSIGNED, PPM (1 Port)

TXP-MR-2_5G.config.client.SDBER

1E-7

1E-5, 1E-6, 1E-7, 1E-8, 1E-9

TXP-MR-2_5G.config.client.SFBER

1E-4

1E-3, 1E-4, 1E-5

TXP-MR-2_5G.config.client.TerminationMode

Transparent

Transparent, Regeneration Section, Multiplex Section when ppmPortAssignment is UNASSIGNED, STM1_PORT, STM4_PORT, STM16_PORT

Transparent when ppmPortAssignment is STM1_PORT, STM4_PORT, STM16_PORT, ONE_GE_PORT, ESCON_PORT, DV6000_PORT, SDI_D1_VIDEO_PORT, HDTV_PORT, PASS_THRU_PORT, ETR_CLO_PORT, ISC compat, FC1G_PORT, FC2G_PORT, FICON1G_PORT, FICON2G_PORT, ISC peer

TXP-MR-2_5G.config.trunk.AINSSoakTime

08:00 (hours:mins)

00:00, 00:15, 00:30 .. 48:00

TXP-MR-2_5G.config.trunk.AlsMode

Disabled

Disabled, Auto Restart, Manual Restart, Manual Restart for Test

TXP-MR-2_5G.config.trunk.AlsRecoveryPulseDuration

40.0 (seconds)

2.0, 2.1, 2.2 .. 100.0 when AlsMode is Disabled, Auto Restart, Manual Restart

80.0, 80.1, 80.2 .. 100.0 when AlsMode is Manual Restart for Test

TXP-MR-2_5G.config.trunk.AlsRecoveryPulseInterval

100 (seconds)

60-300

TXP-MR-2_5G.config.trunk.SDBER

1E-7

1E-5, 1E-6, 1E-7, 1E-8, 1E-9

TXP-MR-2_5G.config.trunk.SFBER

1E-4

1E-3, 1E-4, 1E-5

TXP-MR-2_5G.opticalthresholds.client.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.alarm.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.alarm.LowRxPower

-21.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.alarm.LowTxPower

-15.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.warning.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.warning.15min.HighRxPower

2.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.warning.15min.HighTxPower

2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.warning.15min.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.warning.15min.LowTxPower

-7.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.client.warning.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.client.warning.1day.HighRxPower

2.5 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.warning.1day.HighTxPower

2.5 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.client.warning.1day.LowRxPower

-20.5 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.client.warning.1day.LowTxPower

-7.5 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXP-MR-2_5G.opticalthresholds.trunk.alarm.HighLaserBias

98.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.trunk.alarm.HighRxPower

-8.0 (dBrn)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.trunk.alarm.LowRxPower

-25.0 (dBrn)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.trunk.warning.15min.HighLaserBias

95.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.trunk.warning.15min.HighRxPower

-7.5 (dBrn)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.trunk.warning.15min.LowRxPower

-24.5 (dBrn)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.opticalthresholds.trunk.warning.1day.HighLaserBias

96.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXP-MR-2_5G.opticalthresholds.trunk.warning.1day.HighRxPower

-7.3 (dBrn)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXP-MR-2_5G.opticalthresholds.trunk.warning.1day.LowRxPower

-24.7 (dBrn)

-40.0, -39.9, -39.8 .. HighRxPower

TXP-MR-2_5G.otn.fecthresholds.1gethernet.15min.BitErrorsCorrected

112500 (count)

0-9033621811200

TXP-MR-2_5G.otn.fecthresholds.1gethernet.15min.UncorrectableWords

1 (count)

0-4724697600

TXP-MR-2_5G.otn.fecthresholds.1gethernet.1day.BitErrorsCorrected

10800000 (count)

0-867227693875200

TXP-MR-2_5G.otn.fecthresholds.1gethernet.1day.UncorrectableWords

96 (count)

0-453570969600

TXP-MR-2_5G.otn.fecthresholds.1gfiberchannel.15min.BitErrorsCorrected

90000 (count)

0-9033621811200

TXP-MR-2_5G.otn.fecthresholds.1gfiberchannel.15min.UncorrectableWords

1 (count)

0-4724697600

TXP-MR-2_5G.otn.fecthresholds.1gfiberchannel.1day.BitErrorsCorrected

8640000 (count)

0-867227693875200

TXP-MR-2_5G.otn.fecthresholds.1gfiberchannel.1day.UncorrectableWords

96 (count)

0-453570969600

TXP-MR-2_5G.otn.fecthresholds.1gficon.15min.BitErrorsCorrected

90000 (count)

0-9033621811200

TXP-MR-2_5G.otn.fecthresholds.1gficon.15min.UncorrectableWords

1 (count)

0-4724697600

TXP-MR-2_5G.otn.fecthresholds.1gficon.1day.BitErrorsCorrected

8640000 (count)

0-867227693875200

TXP-MR-2_5G.otn.fecthresholds.1gficon.1day.UncorrectableWords

96 (count)

0-453570969600

TXP-MR-2_5G.otn.fecthresholds.2gfiberchannel.15min.BitErrorsCorrected

180900 (count)

0-9033621811200

TXP-MR-2_5G.otn.fecthresholds.2gfiberchannel.15min.UncorrectableWords

1 (count)

0-4724697600

TXP-MR-2_5G.otn.fecthresholds.2gfiberchannel.1day.BitErrorsCorrected

17366400 (count)

0-867227693875200

TXP-MR-2_5G.otn.fecthresholds.2gfiberchannel.1day.UncorrectableWords

96 (count)

0-453570969600

TXP-MR-2_5G.otn.fecthresholds.2gficon.15min.BitErrorsCorrected

180900 (count)

0-9033621811200

TXP-MR-2_5G.otn.fecthresholds.2gficon.15min.UncorrectableWords

1 (count)

0-4724697600

TXP-MR-2_5G.otn.fecthresholds.2gficon.1day.BitErrorsCorrected

17366400 (count)

0-867227693875200

TXP-MR-2_5G.otn.fecthresholds.2gficon.1day.UncorrectableWords

96 (count)

0-453570969600

TXP-MR-2_5G.otn.fecthresholds.stm1.15min.BitErrorsCorrected

15012 (count)

0-9033621811200

TXP-MR-2_5G.otn.fecthresholds.stm1.15min.UncorrectableWords

1 (count)

0-4724697600

TXP-MR-2_5G.otn.fecthresholds.stm1.1day.BitErrorsCorrected

1441152 (count)

0-867227693875200

TXP-MR-2_5G.otn.fecthresholds.stm1.1day.UncorrectableWords

96 (count)

0-453570969600

TXP-MR-2_5G.otn.fecthresholds.stm16.15min.BitErrorsCorrected

225837 (count)

0-9033621811200

TXP-MR-2_5G.otn.fecthresholds.stm16.15min.UncorrectableWords

1 (count)

0-4724697600

TXP-MR-2_5G.otn.fecthresholds.stm16.1day.BitErrorsCorrected

21680352 (count)

0-867227693875200

TXP-MR-2_5G.otn.fecthresholds.stm16.1day.UncorrectableWords

96 (count)

0-453570969600

TXP-MR-2_5G.otn.fecthresholds.stm4.15min.BitErrorsCorrected

56457 (count)

0-9033621811200

TXP-MR-2_5G.otn.fecthresholds.stm4.15min.UncorrectableWords

1 (count)

0-4724697600

TXP-MR-2_5G.otn.fecthresholds.stm4.1day.BitErrorsCorrected

5419872 (count)

0-867227693875200

TXP-MR-2_5G.otn.fecthresholds.stm4.1day.UncorrectableWords

96 (count)

0-453570969600

TXP-MR-2_5G.otn.g709thresholds.pm.farend.15min.BBE

21260 (count)

0-8850600

TXP-MR-2_5G.otn.g709thresholds.pm.farend.15min.ES

87 (seconds)

0-900

TXP-MR-2_5G.otn.g709thresholds.pm.farend.15min.FC

10 (count)

0-72

TXP-MR-2_5G.otn.g709thresholds.pm.farend.15min.SES

1 (seconds)

0-900

TXP-MR-2_5G.otn.g709thresholds.pm.farend.15min.UAS

3 (seconds)

0-900

TXP-MR-2_5G.otn.g709thresholds.pm.farend.1day.BBE

212600 (count)

0-849657600

TXP-MR-2_5G.otn.g709thresholds.pm.farend.1day.ES

864 (seconds)

0-86400

TXP-MR-2_5G.otn.g709thresholds.pm.farend.1day.FC

40 (count)

0-6912

TXP-MR-2_5G.otn.g709thresholds.pm.farend.1day.SES

4 (seconds)

0-86400

TXP-MR-2_5G.otn.g709thresholds.pm.farend.1day.UAS

10 (seconds)

0-86400

TXP-MR-2_5G.otn.g709thresholds.pm.nearend.15min.BBE

21260 (count)

0-8850600

TXP-MR-2_5G.otn.g709thresholds.pm.nearend.15min.ES

87 (seconds)

0-900

TXP-MR-2_5G.otn.g709thresholds.pm.nearend.15min.FC

10 (count)

0-72

TXP-MR-2_5G.otn.g709thresholds.pm.nearend.15min.SES

1 (seconds)

0-900

TXP-MR-2_5G.otn.g709thresholds.pm.nearend.15min.UAS

3 (seconds)

0-900

TXP-MR-2_5G.otn.g709thresholds.pm.nearend.1day.BBE

212600 (count)

0-849657600

TXP-MR-2_5G.otn.g709thresholds.pm.nearend.1day.ES

864 (seconds)

0-86400

TXP-MR-2_5G.otn.g709thresholds.pm.nearend.1day.FC

40 (count)

0-6912

TXP-MR-2_5G.otn.g709thresholds.pm.nearend.1day.SES

4 (seconds)

0-86400

TXP-MR-2_5G.otn.g709thresholds.pm.nearend.1day.UAS

10 (seconds)

0-86400

TXP-MR-2_5G.otn.g709thresholds.sm.farend.15min.BBE

10000 (count)

0-8850600

TXP-MR-2_5G.otn.g709thresholds.sm.farend.15min.ES

500 (seconds)

0-900

TXP-MR-2_5G.otn.g709thresholds.sm.farend.15min.FC

10 (count)

0-72

TXP-MR-2_5G.otn.g709thresholds.sm.farend.15min.SES

500 (seconds)

0-900

TXP-MR-2_5G.otn.g709thresholds.sm.farend.15min.UAS

500 (seconds)

0-900

TXP-MR-2_5G.otn.g709thresholds.sm.farend.1day.BBE

100000 (count)

0-849657600

TXP-MR-2_5G.otn.g709thresholds.sm.farend.1day.ES

5000 (seconds)

0-86400

TXP-MR-2_5G.otn.g709thresholds.sm.farend.1day.FC

40 (count)

0-6912

TXP-MR-2_5G.otn.g709thresholds.sm.farend.1day.SES

5000 (seconds)

0-86400

TXP-MR-2_5G.otn.g709thresholds.sm.farend.1day.UAS

5000 (seconds)

0-86400

TXP-MR-2_5G.otn.g709thresholds.sm.nearend.15min.BBE

10000 (count)

0-8850600

TXP-MR-2_5G.otn.g709thresholds.sm.nearend.15min.ES

500 (seconds)

0-900

TXP-MR-2_5G.otn.g709thresholds.sm.nearend.15min.FC

10 (count)

0-72

TXP-MR-2_5G.otn.g709thresholds.sm.nearend.15min.SES

500 (seconds)

0-900

TXP-MR-2_5G.otn.g709thresholds.sm.nearend.15min.UAS

500 (seconds)

0-900

TXP-MR-2_5G.otn.g709thresholds.sm.nearend.1day.BBE

100000 (count)

0-849657600

TXP-MR-2_5G.otn.g709thresholds.sm.nearend.1day.ES

5000 (seconds)

0-86400

TXP-MR-2_5G.otn.g709thresholds.sm.nearend.1day.FC

40 (count)

0-6912

TXP-MR-2_5G.otn.g709thresholds.sm.nearend.1day.SES

5000 (seconds)

0-86400

TXP-MR-2_5G.otn.g709thresholds.sm.nearend.1day.UAS

5000 (seconds)

0-86400

TXP-MR-2_5G.otn.otnLines.FEC

Enable

Disable, Enable when G709OTN is Enable

Disable when G709OTN is Disable

TXP-MR-2_5G.otn.otnLines.G709OTN

Enable

Disable, Enable

TXP-MR-2_5G.otn.otnLines.SDBER

1E-7

1E-5, 1E-6, 1E-7, 1E-8, 1E-9

TXP-MR-2_5G.pmthresholds.stm1.ms.farend.15min.BBE

1312 (count)

0-137700

TXP-MR-2_5G.pmthresholds.stm1.ms.farend.15min.EB

1312 (count)

0-137700

TXP-MR-2_5G.pmthresholds.stm1.ms.farend.15min.ES

87 (seconds)

0-900

TXP-MR-2_5G.pmthresholds.stm1.ms.farend.15min.SES

1 (seconds)

0-900

TXP-MR-2_5G.pmthresholds.stm1.ms.farend.15min.UAS

3 (seconds)

0-900

TXP-MR-2_5G.pmthresholds.stm1.ms.farend.1day.BBE

13120 (count)

0-13219200

TXP-MR-2_5G.pmthresholds.stm1.ms.farend.1day.EB

13120 (count)

0-13219200

TXP-MR-2_5G.pmthresholds.stm1.ms.farend.1day.ES

864 (seconds)

0-86400

TXP-MR-2_5G.pmthresholds.stm1.ms.farend.1day.SES

4 (seconds)

0-86400

TXP-MR-2_5G.pmthresholds.stm1.ms.farend.1day.UAS

10 (seconds)

0-86400

TXP-MR-2_5G.pmthresholds.stm1.ms.nearend.15min.BBE

1312 (count)

0-137700

TXP-MR-2_5G.pmthresholds.stm1.ms.nearend.15min.EB

1312 (count)

0-137700

TXP-MR-2_5G.pmthresholds.stm1.ms.nearend.15min.ES

87 (seconds)

0-900

TXP-MR-2_5G.pmthresholds.stm1.ms.nearend.15min.SES

1 (seconds)

0-900

TXP-MR-2_5G.pmthresholds.stm1.ms.nearend.15min.UAS

3 (seconds)

0-900

TXP-MR-2_5G.pmthresholds.stm1.ms.nearend.1day.BBE

13120 (count)

0-13219200

TXP-MR-2_5G.pmthresholds.stm1.ms.nearend.1day.EB

13120 (count)

0-13219200

TXP-MR-2_5G.pmthresholds.stm1.ms.nearend.1day.ES

864 (seconds)

0-86400

TXP-MR-2_5G.pmthresholds.stm1.ms.nearend.1day.SES

4 (seconds)

0-86400

TXP-MR-2_5G.pmthresholds.stm1.ms.nearend.1day.UAS

10 (seconds)

0-86400

TXP-MR-2_5G.pmthresholds.stm1.rs.nearend.15min.BBE

10000 (count)

0-138600

TXP-MR-2_5G.pmthresholds.stm1.rs.nearend.15min.EB

10000 (count)

0-138600

TXP-MR-2_5G.pmthresholds.stm1.rs.nearend.15min.ES

500 (seconds)

0-900

TXP-MR-2_5G.pmthresholds.stm1.rs.nearend.15min.SES

500 (seconds)

0-900

TXP-MR-2_5G.pmthresholds.stm1.rs.nearend.15min.UAS

3 (seconds)

0-900

TXP-MR-2_5G.pmthresholds.stm1.rs.nearend.1day.BBE

10000 (count)

0-13305600

TXP-MR-2_5G.pmthresholds.stm1.rs.nearend.1day.EB

100000 (count)

0-13305600

TXP-MR-2_5G.pmthresholds.stm1.rs.nearend.1day.ES

5000 (seconds)

0-86400

TXP-MR-2_5G.pmthresholds.stm1.rs.nearend.1day.SES

5000 (seconds)

0-86400

TXP-MR-2_5G.pmthresholds.stm1.rs.nearend.1day.UAS

10 (seconds)

0-86400

TXP-MR-2_5G.pmthresholds.stm16.ms.farend.15min.BBE

21260 (count)

0-2212200

TXP-MR-2_5G.pmthresholds.stm16.ms.farend.15min.EB

21260 (count)

0-2212200

TXP-MR-2_5G.pmthresholds.stm16.ms.farend.15min.ES

87 (seconds)

0-900

TXP-MR-2_5G.pmthresholds.stm16.ms.farend.15min.SES

1 (seconds)

0-900

TXP-MR-2_5G.pmthresholds.stm16.ms.farend.15min.UAS

3 (seconds)

0-900

TXP-MR-2_5G.pmthresholds.stm16.ms.farend.1day.BBE

212600 (count)

0-212371200

TXP-MR-2_5G.pmthresholds.stm16.ms.farend.1day.EB

212600 (seconds)

0-212371200

TXP-MR-2_5G.pmthresholds.stm16.ms.farend.1day.ES

864 (seconds)

0-900

TXP-MR-2_5G.pmthresholds.stm16.ms.farend.1day.SES

4 (seconds)

0-86400

TXP-MR-2_5G.pmthresholds.stm16.ms.farend.1day.UAS

10 (seconds)

0-86400

TXP-MR-2_5G.pmthresholds.stm16.ms.nearend.15min.BBE

21260 (count)

0-2212200

TXP-MR-2_5G.pmthresholds.stm16.ms.nearend.15min.EB

21260 (count)

0-2212200

TXP-MR-2_5G.pmthresholds.stm16.ms.nearend.15min.ES

87 (seconds)

0-900

TXP-MR-2_5G.pmthresholds.stm16.ms.nearend.15min.SES

1 (seconds)

0-900

TXP-MR-2_5G.pmthresholds.stm16.ms.nearend.15min.UAS

3 (seconds)

0-900

TXP-MR-2_5G.pmthresholds.stm16.ms.nearend.1day.BBE

212600 (count)

0-212371200

TXP-MR-2_5G.pmthresholds.stm16.ms.nearend.1day.EB

212600 (count)

0-212371200

TXP-MR-2_5G.pmthresholds.stm16.ms.nearend.1day.ES

864 (seconds)

0-86400

TXP-MR-2_5G.pmthresholds.stm16.ms.nearend.1day.SES

4 (seconds)

0-86400

TXP-MR-2_5G.pmthresholds.stm16.ms.nearend.1day.UAS

10 (seconds)

0-86400

TXP-MR-2_5G.pmthresholds.stm16.rs.nearend.15min.BBE

10000 (count)

0-2151900

TXP-MR-2_5G.pmthresholds.stm16.rs.nearend.15min.EB

10000 (count)

0-2151900

TXP-MR-2_5G.pmthresholds.stm16.rs.nearend.15min.ES

500 (seconds)

0-900

TXP-MR-2_5G.pmthresholds.stm16.rs.nearend.15min.SES

500 (seconds)

0-900

TXP-MR-2_5G.pmthresholds.stm16.rs.nearend.15min.UAS

3 (seconds)

0-900

TXP-MR-2_5G.pmthresholds.stm16.rs.nearend.1day.BBE

10000 (count)

0-206582400

TXP-MR-2_5G.pmthresholds.stm16.rs.nearend.1day.EB

100000 (count)

0-206582400

TXP-MR-2_5G.pmthresholds.stm16.rs.nearend.1day.ES

5000 (seconds)

0-86400

TXP-MR-2_5G.pmthresholds.stm16.rs.nearend.1day.SES

5000 (seconds)

0-86400

TXP-MR-2_5G.pmthresholds.stm16.rs.nearend.1day.UAS

10 (seconds)

0-86400

TXP-MR-2_5G.pmthresholds.stm4.ms.farend.15min.BBE

5315 (count)

0-552600

TXP-MR-2_5G.pmthresholds.stm4.ms.farend.15min.EB

5315 (count)

0-552600

TXP-MR-2_5G.pmthresholds.stm4.ms.farend.15min.ES

87 (seconds)

0-900

TXP-MR-2_5G.pmthresholds.stm4.ms.farend.15min.SES

1 (seconds)

0-900

TXP-MR-2_5G.pmthresholds.stm4.ms.farend.15min.UAS

3 (seconds)

0-900

TXP-MR-2_5G.pmthresholds.stm4.ms.farend.1day.BBE

53150 (count)

0-53049600

TXP-MR-2_5G.pmthresholds.stm4.ms.farend.1day.EB

53150 (count)

0-53049600

TXP-MR-2_5G.pmthresholds.stm4.ms.farend.1day.ES

864 (seconds)

0-86400

TXP-MR-2_5G.pmthresholds.stm4.ms.farend.1day.SES

4 (seconds)

0-86400

TXP-MR-2_5G.pmthresholds.stm4.ms.farend.1day.UAS

10 (seconds)

0-86400

TXP-MR-2_5G.pmthresholds.stm4.ms.nearend.15min.BBE

5315 (count)

0-552600

TXP-MR-2_5G.pmthresholds.stm4.ms.nearend.15min.EB

5315 (count)

0-552600

TXP-MR-2_5G.pmthresholds.stm4.ms.nearend.15min.ES

87 (seconds)

0-900

TXP-MR-2_5G.pmthresholds.stm4.ms.nearend.15min.SES

1 (seconds)

0-900

TXP-MR-2_5G.pmthresholds.stm4.ms.nearend.15min.UAS

3 (seconds)

0-900

TXP-MR-2_5G.pmthresholds.stm4.ms.nearend.1day.BBE

53150 (count)

0-53049600

TXP-MR-2_5G.pmthresholds.stm4.ms.nearend.1day.EB

53150 (count)

0-53049600

TXP-MR-2_5G.pmthresholds.stm4.ms.nearend.1day.ES

864 (seconds)

0-86400

TXP-MR-2_5G.pmthresholds.stm4.ms.nearend.1day.SES

4 (seconds)

0-86400

TXP-MR-2_5G.pmthresholds.stm4.ms.nearend.1day.UAS

10 (seconds)

0-86400

TXP-MR-2_5G.pmthresholds.stm4.rs.nearend.15min.BBE

10000 (count)

0-553500

TXP-MR-2_5G.pmthresholds.stm4.rs.nearend.15min.EB

10000 (count)

0-553500

TXP-MR-2_5G.pmthresholds.stm4.rs.nearend.15min.ES

500 (seconds)

0-900

TXP-MR-2_5G.pmthresholds.stm4.rs.nearend.15min.SES

500 (seconds)

0-900

TXP-MR-2_5G.pmthresholds.stm4.rs.nearend.15min.UAS

3 (seconds)

0-900

TXP-MR-2_5G.pmthresholds.stm4.rs.nearend.1day.BBE

10000 (count)

0-53136000

TXP-MR-2_5G.pmthresholds.stm4.rs.nearend.1day.EB

100000 (count)

0-53136000

TXP-MR-2_5G.pmthresholds.stm4.rs.nearend.1day.ES

5000 (seconds)

0-86400

TXP-MR-2_5G.pmthresholds.stm4.rs.nearend.1day.SES

5000 (seconds)

0-86400

TXP-MR-2_5G.pmthresholds.stm4.rs.nearend.1day.UAS

10 (seconds)

0-86400


D.3.1.8  TXPP_MR_2.5G Card Default Settings

Table D-20 lists the TXPP_MR_2.5G card default settings.

Table D-20 TXPP-MR-2.5G Card Default Settings (ETSI) 

Default Name
Default Value
Default Domain

TXPP-MR-2_5G.config.client.AINSSoakTime

08:00 (hours:mins)

00:00, 00:15, 00:30 .. 48:00

TXPP-MR-2_5G.config.client.AlsMode

Disabled

Disabled, Auto Restart, Manual Restart, Manual Restart for Test

TXPP-MR-2_5G.config.client.AlsRecoveryPulseDuration

40.0 (seconds)

2.0, 2.1, 2.2 .. 100.0 when AlsMode is Disabled, Auto Restart, Manual Restart

80.0, 80.1, 80.2 .. 100.0 when AlsMode is Manual Restart for Test

TXPP-MR-2_5G.config.client.AlsRecoveryPulseInterval

100 (seconds)

60-300

TXPP-MR-2_5G.config.client.ppmPortAssignment

UNASSIGNED

UNASSIGNED, STM1_PORT, STM4_PORT, STM16_PORT, ONE_GE_PORT, ESCON_PORT, DV6000_PORT, SDI_D1_VIDEO_PORT, HDTV_PORT, PASS_THRU_PORT, ETR_CLO_PORT, ISC compat, FC1G_PORT, FC2G_PORT, FICON1G_PORT, FICON2G_PORT, ISC peer

TXPP-MR-2_5G.config.client.ppmSlotAssignment

UNASSIGNED

UNASSIGNED, PPM (1 Port)

TXPP-MR-2_5G.config.client.SDBER

1E-7

1E-5, 1E-6, 1E-7, 1E-8, 1E-9

TXPP-MR-2_5G.config.client.SFBER

1E-4

1E-3, 1E-4, 1E-5

TXPP-MR-2_5G.config.client.TerminationMode

Transparent

Transparent, Regeneration Section, Multiplex Section when ppmPortAssignment is UNASSIGNED, STM1_PORT, STM4_PORT, STM16_PORT

Transparent when ppmPortAssignment is STM1_PORT, STM4_PORT, STM16_PORT, ONE_GE_PORT, ESCON_PORT, DV6000_PORT, SDI_D1_VIDEO_PORT, HDTV_PORT, PASS_THRU_PORT, ETR_CLO_PORT, ISC compat, FC1G_PORT, FC2G_PORT, FICON1G_PORT, FICON2G_PORT, ISC peer

TXPP-MR-2_5G.config.trunk.AINSSoakTime

08:00 (hours:mins)

00:00, 00:15, 00:30 .. 48:00

TXPP-MR-2_5G.config.trunk.AlsMode

Disabled

Disabled, Auto Restart, Manual Restart, Manual Restart for Test

TXPP-MR-2_5G.config.trunk.AlsRecoveryPulseDuration

40.0 (seconds)

2.0, 2.1, 2.2 .. 100.0 when AlsMode is Disabled, Auto Restart, Manual Restart

80.0, 80.1, 80.2 .. 100.0 when AlsMode is Manual Restart for Test

TXPP-MR-2_5G.config.trunk.AlsRecoveryPulseInterval

100 (seconds)

60-300

TXPP-MR-2_5G.config.trunk.SDBER

1E-7

1E-5, 1E-6, 1E-7, 1E-8, 1E-9

TXPP-MR-2_5G.config.trunk.SFBER

1E-4

1E-3, 1E-4, 1E-5

TXPP-MR-2_5G.opticalthresholds.client.alarm.HighLaserBias

90.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.alarm.HighRxPower

3.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.alarm.HighTxPower

3.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.alarm.LowRxPower

-21.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.alarm.LowTxPower

-15.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.warning.15min.HighLaserBias

81.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.warning.15min.HighRxPower

2.0 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.warning.15min.HighTxPower

2.0 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.warning.15min.LowRxPower

-20.0 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.warning.15min.LowTxPower

-7.0 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.client.warning.1day.HighLaserBias

85.5 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.client.warning.1day.HighRxPower

2.5 (dBm)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.warning.1day.HighTxPower

2.5 (dBm)

LowTxPower, LowTxPower + 0.1, LowTxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.client.warning.1day.LowRxPower

-20.5 (dBm)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.client.warning.1day.LowTxPower

-7.5 (dBm)

-40.0, -39.9, -39.8 .. HighTxPower

TXPP-MR-2_5G.opticalthresholds.trunk.alarm.HighLaserBias

98.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.trunk.alarm.HighRxPower

-8.0 (dBrn)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.trunk.alarm.LowRxPower

-25.0 (dBrn)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.trunk.warning.15min.HighLaserBias

95.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.trunk.warning.15min.HighRxPower

-7.5 (dBrn)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.trunk.warning.15min.LowRxPower

-24.5 (dBrn)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.opticalthresholds.trunk.warning.1day.HighLaserBias

96.0 (%)

0.0, 0.1, 0.2 .. 100.0

TXPP-MR-2_5G.opticalthresholds.trunk.warning.1day.HighRxPower

-7.3 (dBrn)

LowRxPower, LowRxPower + 0.1, LowRxPower + 0.2 .. 30.0

TXPP-MR-2_5G.opticalthresholds.trunk.warning.1day.LowRxPower

-24.7 (dBrn)

-40.0, -39.9, -39.8 .. HighRxPower

TXPP-MR-2_5G.otn.fecthresholds.1gethernet.15min.BitErrorsCorrected

112500 (count)

0-9033621811200

TXPP-MR-2_5G.otn.fecthresholds.1gethernet.15min.UncorrectableWords

1 (count)

0-4724697600

TXPP-MR-2_5G.otn.fecthresholds.1gethernet.1day.BitErrorsCorrected

10800000 (count)

0-867227693875200

TXPP-MR-2_5G.otn.fecthresholds.1gethernet.1day.UncorrectableWords

96 (count)

0-453570969600

TXPP-MR-2_5G.otn.fecthresholds.1gfiberchannel.15min.BitErrorsCorrected

90000 (count)

0-9033621811200

TXPP-MR-2_5G.otn.fecthresholds.1gfiberchannel.15min.UncorrectableWords

1 (count)

0-4724697600

TXPP-MR-2_5G.otn.fecthresholds.1gfiberchannel.1day.BitErrorsCorrected

8640000 (count)

0-867227693875200

TXPP-MR-2_5G.otn.fecthresholds.1gfiberchannel.1day.UncorrectableWords

96 (count)

0-453570969600

TXPP-MR-2_5G.otn.fecthresholds.1gficon.15min.BitErrorsCorrected

90000 (count)

0-9033621811200

TXPP-MR-2_5G.otn.fecthresholds.1gficon.15min.UncorrectableWords

1 (count)

0-4724697600

TXPP-MR-2_5G.otn.fecthresholds.1gficon.1day.BitErrorsCorrected

8640000 (count)

0-867227693875200

TXPP-MR-2_5G.otn.fecthresholds.1gficon.1day.UncorrectableWords

96 (count)

0-453570969600

TXPP-MR-2_5G.otn.fecthresholds.2gfiberchannel.15min.BitErrorsCorrected

180900 (count)

0-9033621811200

TXPP-MR-2_5G.otn.fecthresholds.2gfiberchannel.15min.UncorrectableWords

1 (count)

0-4724697600

TXPP-MR-2_5G.otn.fecthresholds.2gfiberchannel.1day.BitErrorsCorrected

17366400 (count)

0-867227693875200

TXPP-MR-2_5G.otn.fecthresholds.2gfiberchannel.1day.UncorrectableWords

96 (count)

0-453570969600

TXPP-MR-2_5G.otn.fecthresholds.2gficon.15min.BitErrorsCorrected

180900 (count)

0-9033621811200

TXPP-MR-2_5G.otn.fecthresholds.2gficon.15min.UncorrectableWords

1 (count)

0-4724697600

TXPP-MR-2_5G.otn.fecthresholds.2gficon.1day.BitErrorsCorrected

17366400 (count)

0-867227693875200

TXPP-MR-2_5G.otn.fecthresholds.2gficon.1day.UncorrectableWords

96 (count)

0-453570969600

TXPP-MR-2_5G.otn.fecthresholds.stm1.15min.BitErrorsCorrected

15012 (count)

0-9033621811200

TXPP-MR-2_5G.otn.fecthresholds.stm1.15min.UncorrectableWords

1 (count)

0-4724697600

TXPP-MR-2_5G.otn.fecthresholds.stm1.1day.BitErrorsCorrected

1441152 (count)

0-867227693875200

TXPP-MR-2_5G.otn.fecthresholds.stm1.1day.UncorrectableWords

96 (count)

0-453570969600

TXPP-MR-2_5G.otn.fecthresholds.stm16.15min.BitErrorsCorrected

225837 (count)

0-9033621811200

TXPP-MR-2_5G.otn.fecthresholds.stm16.15min.UncorrectableWords

1 (count)

0-4724697600

TXPP-MR-2_5G.otn.fecthresholds.stm16.1day.BitErrorsCorrected

21680352 (count)

0-867227693875200

TXPP-MR-2_5G.otn.fecthresholds.stm16.1day.UncorrectableWords

96 (count)

0-453570969600

TXPP-MR-2_5G.otn.fecthresholds.stm4.15min.BitErrorsCorrected

56457 (count)

0-9033621811200

TXPP-MR-2_5G.otn.fecthresholds.stm4.15min.UncorrectableWords

1 (count)

0-4724697600

TXPP-MR-2_5G.otn.fecthresholds.stm4.1day.BitErrorsCorrected

5419872 (count)

0-867227693875200

TXPP-MR-2_5G.otn.fecthresholds.stm4.1day.UncorrectableWords

96 (count)

0-453570969600

TXPP-MR-2_5G.otn.g709thresholds.pm.farend.15min.BBE

21260 (count)

0-8850600

TXPP-MR-2_5G.otn.g709thresholds.pm.farend.15min.ES

87 (seconds)

0-900

TXPP-MR-2_5G.otn.g709thresholds.pm.farend.15min.FC

10 (count)

0-72

TXPP-MR-2_5G.otn.g709thresholds.pm.farend.15min.SES

1 (seconds)

0-900

TXPP-MR-2_5G.otn.g709thresholds.pm.farend.15min.UAS

3 (seconds)

0-900

TXPP-MR-2_5G.otn.g709thresholds.pm.farend.1day.BBE

212600 (count)

0-849657600

TXPP-MR-2_5G.otn.g709thresholds.pm.farend.1day.ES

864 (seconds)

0-86400

TXPP-MR-2_5G.otn.g709thresholds.pm.farend.1day.FC

40 (count)

0-6912

TXPP-MR-2_5G.otn.g709thresholds.pm.farend.1day.SES

4 (seconds)

0-86400

TXPP-MR-2_5G.otn.g709thresholds.pm.farend.1day.UAS

10 (seconds)

0-86400

TXPP-MR-2_5G.otn.g709thresholds.pm.nearend.15min.BBE

21260 (count)

0-8850600

TXPP-MR-2_5G.otn.g709thresholds.pm.nearend.15min.ES

87 (seconds)

0-900

TXPP-MR-2_5G.otn.g709thresholds.pm.nearend.15min.FC

10 (count)

0-72

TXPP-MR-2_5G.otn.g709thresholds.pm.nearend.15min.SES

1 (seconds)

0-900

TXPP-MR-2_5G.otn.g709thresholds.pm.nearend.15min.UAS

3 (seconds)

0-900

TXPP-MR-2_5G.otn.g709thresholds.pm.nearend.1day.BBE

212600 (count)

0-849657600

TXPP-MR-2_5G.otn.g709thresholds.pm.nearend.1day.ES

864 (seconds)

0-86400

TXPP-MR-2_5G.otn.g709thresholds.pm.nearend.1day.FC

40 (count)

0-6912

TXPP-MR-2_5G.otn.g709thresholds.pm.nearend.1day.SES

4 (seconds)

0-86400

TXPP-MR-2_5G.otn.g709thresholds.pm.nearend.1day.UAS

10 (seconds)

0-86400

TXPP-MR-2_5G.otn.g709thresholds.sm.farend.15min.BBE

10000 (count)

0-8850600

TXPP-MR-2_5G.otn.g709thresholds.sm.farend.15min.ES

500 (seconds)

0-900

TXPP-MR-2_5G.otn.g709thresholds.sm.farend.15min.FC

10 (count)

0-72

TXPP-MR-2_5G.otn.g709thresholds.sm.farend.15min.SES

500 (seconds)

0-900

TXPP-MR-2_5G.otn.g709thresholds.sm.farend.15min.UAS

500 (seconds)

0-900

TXPP-MR-2_5G.otn.g709thresholds.sm.farend.1day.BBE

100000 (count)

0-849657600

TXPP-MR-2_5G.otn.g709thresholds.sm.farend.1day.ES

5000 (seconds)

0-86400

TXPP-MR-2_5G.otn.g709thresholds.sm.farend.1day.FC

40 (count)

0-6912

TXPP-MR-2_5G.otn.g709thresholds.sm.farend.1day.SES

5000 (seconds)

0-86400

TXPP-MR-2_5G.otn.g709thresholds.sm.farend.1day.UAS

5000 (seconds)

0-86400

TXPP-MR-2_5G.otn.g709thresholds.sm.nearend.15min.BBE

10000 (count)

0-8850600

TXPP-MR-2_5G.otn.g709thresholds.sm.nearend.15min.ES

500 (seconds)

0-900

TXPP-MR-2_5G.otn.g709thresholds.sm.nearend.15min.FC

10 (count)

0-72

TXPP-MR-2_5G.otn.g709thresholds.sm.nearend.15min.SES

500 (seconds)

0-900

TXPP-MR-2_5G.otn.g709thresholds.sm.nearend.15min.UAS

500 (seconds)

0-900

TXPP-MR-2_5G.otn.g709thresholds.sm.nearend.1day.BBE

100000 (count)

0-849657600

TXPP-MR-2_5G.otn.g709thresholds.sm.nearend.1day.ES

5000 (seconds)

0-86400

TXPP-MR-2_5G.otn.g709thresholds.sm.nearend.1day.FC

40 (count)

0-6912

TXPP-MR-2_5G.otn.g709thresholds.sm.nearend.1day.SES

5000 (seconds)

0-86400

TXPP-MR-2_5G.otn.g709thresholds.sm.nearend.1day.UAS

5000 (seconds)

0-86400

TXPP-MR-2_5G.otn.otnLines.FEC

Enable

Disable, Enable when G709OTN is Enable

Disable when G709OTN is Disable

TXPP-MR-2_5G.otn.otnLines.G709OTN

Enable

Disable, Enable

TXPP-MR-2_5G.otn.otnLines.SDBER

1E-7

1E-5, 1E-6, 1E-7, 1E-8, 1E-9

TXPP-MR-2_5G.pmthresholds.stm1.ms.farend.15min.BBE

1312 (count)

0-137700

TXPP-MR-2_5G.pmthresholds.stm1.ms.farend.15min.EB

1312 (count)

0-137700

TXPP-MR-2_5G.pmthresholds.stm1.ms.farend.15min.ES

87 (seconds)

0-900

TXPP-MR-2_5G.pmthresholds.stm1.ms.farend.15min.SES

1 (seconds)

0-900

TXPP-MR-2_5G.pmthresholds.stm1.ms.farend.15min.UAS

3 (seconds)

0-900

TXPP-MR-2_5G.pmthresholds.stm1.ms.farend.1day.BBE

13120 (count)

0-13219200

TXPP-MR-2_5G.pmthresholds.stm1.ms.farend.1day.EB

13120 (count)

0-13219200

TXPP-MR-2_5G.pmthresholds.stm1.ms.farend.1day.ES

864 (seconds)

0-86400

TXPP-MR-2_5G.pmthresholds.stm1.ms.farend.1day.SES

4 (seconds)

0-86400

TXPP-MR-2_5G.pmthresholds.stm1.ms.farend.1day.UAS

10 (seconds)

0-86400

TXPP-MR-2_5G.pmthresholds.stm1.ms.nearend.15min.BBE

1312 (count)

0-137700

TXPP-MR-2_5G.pmthresholds.stm1.ms.nearend.15min.EB

1312 (count)

0-137700

TXPP-MR-2_5G.pmthresholds.stm1.ms.nearend.15min.ES

87 (seconds)

0-900

TXPP-MR-2_5G.pmthresholds.stm1.ms.nearend.15min.SES

1 (seconds)

0-900

TXPP-MR-2_5G.pmthresholds.stm1.ms.nearend.15min.UAS

3 (seconds)

0-900

TXPP-MR-2_5G.pmthresholds.stm1.ms.nearend.1day.BBE

13120 (count)

0-13219200

TXPP-MR-2_5G.pmthresholds.stm1.ms.nearend.1day.EB

13120 (count)

0-13219200

TXPP-MR-2_5G.pmthresholds.stm1.ms.nearend.1day.ES

864 (seconds)

0-86400

TXPP-MR-2_5G.pmthresholds.stm1.ms.nearend.1day.SES

4 (seconds)

0-86400

TXPP-MR-2_5G.pmthresholds.stm1.ms.nearend.1day.UAS

10 (seconds)

0-86400

TXPP-MR-2_5G.pmthresholds.stm1.rs.nearend.15min.BBE

10000 (count)

0-138600

TXPP-MR-2_5G.pmthresholds.stm1.rs.nearend.15min.EB

10000 (count)

0-138600

TXPP-MR-2_5G.pmthresholds.stm1.rs.nearend.15min.ES

500 (seconds)

0-900

TXPP-MR-2_5G.pmthresholds.stm1.rs.nearend.15min.SES

500 (seconds)

0-900

TXPP-MR-2_5G.pmthresholds.stm1.rs.nearend.15min.UAS

3 (seconds)

0-900

TXPP-MR-2_5G.pmthresholds.stm1.rs.nearend.1day.BBE

10000 (count)

0-13305600

TXPP-MR-2_5G.pmthresholds.stm1.rs.nearend.1day.EB

100000 (count)

0-13305600

TXPP-MR-2_5G.pmthresholds.stm1.rs.nearend.1day.ES

5000 (seconds)

0-86400

TXPP-MR-2_5G.pmthresholds.stm1.rs.nearend.1day.SES

5000 (seconds)

0-86400

TXPP-MR-2_5G.pmthresholds.stm1.rs.nearend.1day.UAS

10 (seconds)

0-86400

TXPP-MR-2_5G.pmthresholds.stm16.ms.farend.15min.BBE

21260 (count)

0-2212200

TXPP-MR-2_5G.pmthresholds.stm16.ms.farend.15min.EB

21260 (count)

0-2212200

TXPP-MR-2_5G.pmthresholds.stm16.ms.farend.15min.ES

87 (seconds)

0-900

TXPP-MR-2_5G.pmthresholds.stm16.ms.farend.15min.SES

1 (seconds)

0-900

TXPP-MR-2_5G.pmthresholds.stm16.ms.farend.15min.UAS

3 (seconds)

0-900

TXPP-MR-2_5G.pmthresholds.stm16.ms.farend.1day.BBE

212600 (count)

0-212371200

TXPP-MR-2_5G.pmthresholds.stm16.ms.farend.1day.EB

212600 (seconds)

0-212371200

TXPP-MR-2_5G.pmthresholds.stm16.ms.farend.1day.ES

864 (seconds)

0-900

TXPP-MR-2_5G.pmthresholds.stm16.ms.farend.1day.SES

4 (seconds)

0-86400

TXPP-MR-2_5G.pmthresholds.stm16.ms.farend.1day.UAS

10 (seconds)

0-86400

TXPP-MR-2_5G.pmthresholds.stm16.ms.nearend.15min.BBE

21260 (count)

0-2212200

TXPP-MR-2_5G.pmthresholds.stm16.ms.nearend.15min.EB

21260 (count)

0-2212200

TXPP-MR-2_5G.pmthresholds.stm16.ms.nearend.15min.ES

87 (seconds)

0-900

TXPP-MR-2_5G.pmthresholds.stm16.ms.nearend.15min.SES

1 (seconds)

0-900

TXPP-MR-2_5G.pmthresholds.stm16.ms.nearend.15min.UAS

3 (seconds)

0-900

TXPP-MR-2_5G.pmthresholds.stm16.ms.nearend.1day.BBE

212600 (count)

0-212371200

TXPP-MR-2_5G.pmthresholds.stm16.ms.nearend.1day.EB

212600 (count)

0-212371200

TXPP-MR-2_5G.pmthresholds.stm16.ms.nearend.1day.ES

864 (seconds)

0-86400

TXPP-MR-2_5G.pmthresholds.stm16.ms.nearend.1day.SES

4 (seconds)

0-86400

TXPP-MR-2_5G.pmthresholds.stm16.ms.nearend.1day.UAS

10 (seconds)

0-86400

TXPP-MR-2_5G.pmthresholds.stm16.rs.nearend.15min.BBE

10000 (count)

0-2151900

TXPP-MR-2_5G.pmthresholds.stm16.rs.nearend.15min.EB

10000 (count)

0-2151900

TXPP-MR-2_5G.pmthresholds.stm16.rs.nearend.15min.ES

500 (seconds)

0-900

TXPP-MR-2_5G.pmthresholds.stm16.rs.nearend.15min.SES

500 (seconds)

0-900

TXPP-MR-2_5G.pmthresholds.stm16.rs.nearend.15min.UAS

3 (seconds)

0-900

TXPP-MR-2_5G.pmthresholds.stm16.rs.nearend.1day.BBE

10000 (count)

0-206582400

TXPP-MR-2_5G.pmthresholds.stm16.rs.nearend.1day.EB

100000 (count)

0-206582400

TXPP-MR-2_5G.pmthresholds.stm16.rs.nearend.1day.ES

5000 (seconds)

0-86400

TXPP-MR-2_5G.pmthresholds.stm16.rs.nearend.1day.SES

5000 (seconds)

0-86400

TXPP-MR-2_5G.pmthresholds.stm16.rs.nearend.1day.UAS

10 (seconds)

0-86400

TXPP-MR-2_5G.pmthresholds.stm4.ms.farend.15min.BBE

5315 (count)

0-552600

TXPP-MR-2_5G.pmthresholds.stm4.ms.farend.15min.EB

5315 (count)

0-552600

TXPP-MR-2_5G.pmthresholds.stm4.ms.farend.15min.ES

87 (seconds)

0-900

TXPP-MR-2_5G.pmthresholds.stm4.ms.farend.15min.SES

1 (seconds)

0-900

TXPP-MR-2_5G.pmthresholds.stm4.ms.farend.15min.UAS

3 (seconds)

0-900

TXPP-MR-2_5G.pmthresholds.stm4.ms.farend.1day.BBE

53150 (count)

0-53049600

TXPP-MR-2_5G.pmthresholds.stm4.ms.farend.1day.EB

53150 (count)

0-53049600

TXPP-MR-2_5G.pmthresholds.stm4.ms.farend.1day.ES

864 (seconds)

0-86400

TXPP-MR-2_5G.pmthresholds.stm4.ms.farend.1day.SES

4 (seconds)

0-86400

TXPP-MR-2_5G.pmthresholds.stm4.ms.farend.1day.UAS

10 (seconds)

0-86400

TXPP-MR-2_5G.pmthresholds.stm4.ms.nearend.15min.BBE

5315 (count)

0-552600

TXPP-MR-2_5G.pmthresholds.stm4.ms.nearend.15min.EB

5315 (count)

0-552600

TXPP-MR-2_5G.pmthresholds.stm4.ms.nearend.15min.ES

87 (seconds)

0-900

TXPP-MR-2_5G.pmthresholds.stm4.ms.nearend.15min.SES

1 (seconds)

0-900

TXPP-MR-2_5G.pmthresholds.stm4.ms.nearend.15min.UAS

3 (seconds)

0-900

TXPP-MR-2_5G.pmthresholds.stm4.ms.nearend.1day.BBE

53150 (count)

0-53049600

TXPP-MR-2_5G.pmthresholds.stm4.ms.nearend.1day.EB

53150 (count)

0-53049600

TXPP-MR-2_5G.pmthresholds.stm4.ms.nearend.1day.ES

864 (seconds)

0-86400

TXPP-MR-2_5G.pmthresholds.stm4.ms.nearend.1day.SES

4 (seconds)

0-86400

TXPP-MR-2_5G.pmthresholds.stm4.ms.nearend.1day.UAS

10 (seconds)

0-86400

TXPP-MR-2_5G.pmthresholds.stm4.rs.nearend.15min.BBE

10000 (count)

0-553500

TXPP-MR-2_5G.pmthresholds.stm4.rs.nearend.15min.EB

10000 (count)

0-553500

TXPP-MR-2_5G.pmthresholds.stm4.rs.nearend.15min.ES

500 (seconds)

0-900

TXPP-MR-2_5G.pmthresholds.stm4.rs.nearend.15min.SES

500 (seconds)

0-900

TXPP-MR-2_5G.pmthresholds.stm4.rs.nearend.15min.UAS

3 (seconds)

0-900

TXPP-MR-2_5G.pmthresholds.stm4.rs.nearend.1day.BBE

10000 (count)

0-53136000

TXPP-MR-2_5G.pmthresholds.stm4.rs.nearend.1day.EB

100000 (count)

0-53136000

TXPP-MR-2_5G.pmthresholds.stm4.rs.nearend.1day.ES

5000 (seconds)

0-86400

TXPP-MR-2_5G.pmthresholds.stm4.rs.nearend.1day.SES

5000 (seconds)

0-86400

TXPP-MR-2_5G.pmthresholds.stm4.rs.nearend.1day.UAS

10 (seconds)

0-86400


D.3.1.9  OSCM Card Default Settings

Table D-21 lists the OSCM card default settings.

Table D-21 OSCM Card Default Settings (ETSI) 

Default Name
Default Value
Default Domain

OSCM.pmthresholds.ms.farend.15min.BBE

1312 (count)

0-137700

OSCM.pmthresholds.ms.farend.15min.EB

1312 (count)

0-137700

OSCM.pmthresholds.ms.farend.15min.ES

87 (seconds)

0-900

OSCM.pmthresholds.ms.farend.15min.SES

1 (seconds)

0-900

OSCM.pmthresholds.ms.farend.15min.UAS

3 (seconds)

0-900

OSCM.pmthresholds.ms.farend.1day.BBE

13120 (count)

0-13219200

OSCM.pmthresholds.ms.farend.1day.EB

13120 (count)

0-13219200

OSCM.pmthresholds.ms.farend.1day.ES

864 (seconds)

0-86400

OSCM.pmthresholds.ms.farend.1day.SES

4 (seconds)

0-86400

OSCM.pmthresholds.ms.farend.1day.UAS

10 (seconds)

0-86400

OSCM.pmthresholds.ms.nearend.15min.BBE

1312 (count)

0-137700

OSCM.pmthresholds.ms.nearend.15min.EB

1312 (count)

0-137700

OSCM.pmthresholds.ms.nearend.15min.ES

87 (seconds)

0-900

OSCM.pmthresholds.ms.nearend.15min.SES

1 (seconds)

0-900

OSCM.pmthresholds.ms.nearend.15min.UAS

3 (seconds)

0-900

OSCM.pmthresholds.ms.nearend.1day.BBE

13120 (count)

0-13219200

OSCM.pmthresholds.ms.nearend.1day.EB

13120 (count)

0-13219200

OSCM.pmthresholds.ms.nearend.1day.ES

864 (seconds)

0-86400

OSCM.pmthresholds.ms.nearend.1day.SES

4 (seconds)

0-86400

OSCM.pmthresholds.ms.nearend.1day.UAS

10 (seconds)

0-86400

OSCM.pmthresholds.rs.nearend.15min.BBE

10000 (count)

0-138600

OSCM.pmthresholds.rs.nearend.15min.EB

10000 (count)

0-138600

OSCM.pmthresholds.rs.nearend.15min.ES

500 (seconds)

0-900

OSCM.pmthresholds.rs.nearend.15min.SEFS

500 (seconds)

0-900

OSCM.pmthresholds.rs.nearend.15min.SES

500 (seconds)

0-900

OSCM.pmthresholds.rs.nearend.1day.BBE

100000 (count)

0-13305600

OSCM.pmthresholds.rs.nearend.1day.EB

100000 (count)

0-13305600

OSCM.pmthresholds.rs.nearend.1day.ES

5000 (seconds)

0-86400

OSCM.pmthresholds.rs.nearend.1day.SEFS

5000 (seconds)

0-86400

OSCM.pmthresholds.rs.nearend.1day.SES

5000 (seconds)

0-86400


D.3.1.10  OSC-CSM Card Default Settings

Table D-22 lists the OSC-CSM card default settings.

Table D-22 OSC-CSM Card Default Settings (ETSI) 

Default Name
Default Value
Default Domain

OSC_CSM.pmthresholds.ms.farend.15min.BBE

1312 (count)

0-137700

OSC_CSM.pmthresholds.ms.farend.15min.EB

1312 (count)

0-137700

OSC_CSM.pmthresholds.ms.farend.15min.ES

87 (seconds)

0-900

OSC_CSM.pmthresholds.ms.farend.15min.SES

1 (seconds)

0-900

OSC_CSM.pmthresholds.ms.farend.15min.UAS

3 (seconds)

0-900

OSC_CSM.pmthresholds.ms.farend.1day.BBE

13120 (count)

0-13219200

OSC_CSM.pmthresholds.ms.farend.1day.EB

13120 (count)

0-13219200

OSC_CSM.pmthresholds.ms.farend.1day.ES

864 (seconds)

0-86400

OSC_CSM.pmthresholds.ms.farend.1day.SES

4 (seconds)

0-86400

OSC_CSM.pmthresholds.ms.farend.1day.UAS

10 (seconds)

0-86400

OSC_CSM.pmthresholds.ms.nearend.15min.BBE

1312 (count)

0-137700

OSC_CSM.pmthresholds.ms.nearend.15min.EB

1312 (count)

0-137700

OSC_CSM.pmthresholds.ms.nearend.15min.ES

87 (seconds)

0-900

OSC_CSM.pmthresholds.ms.nearend.15min.SES

1 (seconds)

0-900

OSC_CSM.pmthresholds.ms.nearend.15min.UAS

3 (seconds)

0-900

OSC_CSM.pmthresholds.ms.nearend.1day.BBE

13120 (count)

0-13219200

OSC_CSM.pmthresholds.ms.nearend.1day.EB

13120 (count)

0-13219200

OSC_CSM.pmthresholds.ms.nearend.1day.ES

864 (seconds)

0-86400

OSC_CSM.pmthresholds.ms.nearend.1day.SES

4 (seconds)

0-86400

OSC_CSM.pmthresholds.ms.nearend.1day.UAS

10 (seconds)

0-86400

OSC_CSM.pmthresholds.rs.nearend.15min.BBE

10000 (count)

0-138600

OSC_CSM.pmthresholds.rs.nearend.15min.EB

10000 (count)

0-138600

OSC_CSM.pmthresholds.rs.nearend.15min.ES

500 (seconds)

0-900

OSC_CSM.pmthresholds.rs.nearend.15min.SEFS

500 (seconds)

0-900

OSC_CSM.pmthresholds.rs.nearend.15min.SES

500 (seconds)

0-900

OSC_CSM.pmthresholds.rs.nearend.1day.BBE

100000 (count)

0-13305600

OSC_CSM.pmthresholds.rs.nearend.1day.EB

100000 (count)

0-13305600

OSC_CSM.pmthresholds.rs.nearend.1day.ES

5000 (seconds)

0-86400

OSC_CSM.pmthresholds.rs.nearend.1day.SEFS

5000 (seconds)

0-86400

OSC_CSM.pmthresholds.rs.nearend.1day.SES

5000 (seconds)

0-86400


D.3.2  ETSI Node Default Settings

Table D-23 lists the Cisco ONS 15454 node-level default settings for the ETSI shelf assembly. Cisco provides the following user-configurable defaults for each Cisco ONS 15454 node:

SNCP settings—Set the threshold level for signal degradation and failure for subnetwork connection protection (SNCP) circuits.

Craft Access Only—Allows CTC connectivity to the node only through the craft access port.

CTC IP Display Suppression—Prevents display of node IP addresses in CTC (applicable for all users except Superusers).

Defaults Description—Names the current defaults file on the node.

Enable Firewall—Enables or disables the use of a firewall for accessing the node.

Enable Proxy—Enables or disables the use of a proxy server with the node.

IIOP Listener Port—Sets the IIOP listener port number.

LCD IP setting—Sets the node LCD screen to display the node IP address and use the buttons on the LCD panel, only display the IP address, or suppress display of the IP address.

Login Warning Message—Warns users at the login screen about the possible legal or contractual ramifications of accessing equipment, systems, or networks without authorization.

NTP SNTP Server—Sets the IP address of the NTP SNTP server to be used with the node.

Time Zone—Sets the time zone where the node is located.

Use DST—Enables or disables the use of Daylight Savings Time.

Use NTP SNTP Server—Enables or disables the use of the specified NTP SNTP server with the node.

Linear Multiplex Section Protection (LMSP) settings—Determine whether or not LMSP-protected circuits have bidirectional switching, are revertive, and what the reversion time is.

MS-SPRing protection settings—Determine whether multiplex section-shared protection ring (MS-SPRing) protected circuits are revertive and what the reversion time is at both the ring and span levels.

Y Cable Protection settings—Determine whether Y-cable protected circuits have bidirectional switching, are revertive, and what the reversion time is.

Security Policy settings—Determine the allowable failed logins before lockout, idle user timeout for each user level, optional lockout duration or manual unlock enabled, password reuse and change frequency policies, number of characters difference between the old and new password, password aging by security level, enforced single concurrent session per user, and disable inactive user after a set inactivity period.

BITS Timing settings—Determine the AIS threshold, coding, framing, State, State Out, and LBO settings for BITS1 and BITS2 timing.

General Timing settings—Determine the mode (External, Line, or Mixed), quality of RES, revertive, reversion time, and SSM message set for node timing.


Note For more information about each individual node setting, see Chapter 10, "Manage the Node."


Table D-23 Node Default Settings (ETSI) 

Default Name
Default Value
Default Domain

NODE.circuits.sncp.HO_SDBER

1E-6

1E-5, 1E-6, 1E-7, 1E-8, 1E-9

NODE.circuits.sncp.HO_SFBER

1E-4

1E-3, 1E-4, 1E-5

NODE.circuits.sncp.LO_SDBER

1E-6

1E-5, 1E-6, 1E-7, 1E-8

NODE.circuits.sncp.LO_SFBER

1E-4

1E-3, 1E-4, 1E-5

NODE.circuits.sncp.ReversionTime

5.0 (minutes)

0.5, 1.0, 1.5 .. 12.0

NODE.circuits.sncp.Revertive

FALSE

TRUE, FALSE

NODE.circuits.State

unlocked, automaticInService

unlocked, locked, disabled, locked, maintenance, unlocked, automaticInService

NODE.general.DefaultsDescription

Factory Defaults

Free form field

NODE.general.NtpSntpServer

0.0.0.0

IP Address

NODE.general.TimeZone

(GMT-08:00) Pacific Time (US & Canada), Tijuana

(For applicable time zones, see Table D-24.)

NODE.general.UseDST

TRUE

TRUE, FALSE

NODE.network.general.AlarmMissingBackplaneLAN

FALSE

TRUE, FALSE

NODE.network.general.CtcIpDisplaySuppression

FALSE

TRUE, FALSE

NODE.network.general.GatewaySettings

None

LeaveAsIs, None, ENE, GNE, ProxyOnlyNode

NODE.network.general.LcdIpSetting

Allow Configuration

Allow Configuration, Display Only, Suppress Display

NODE.osi.greTunnel.ctc.OspfCost

110

110, 120, 130 .. 65530

NODE.osi.greTunnel.ctc.SubnetMask

24 (bits)

8, 9, 10 .. 32

NODE.osi.lapd.ctc.Mode

AITS

AITS, UITS

NODE.osi.lapd.ctc.MTU

512

512, 513, 514 .. 1500

NODE.osi.lapd.ctc.Role

Network

Network, User

NODE.osi.lapd.ctc.T200

200 (ms)

200, 300, 400 .. 20000

NODE.osi.lapd.ctc.T203

10000 (ms)

4000, 4100, 4200 .. 120000

NODE.osi.mainSetup.L1L2LSPBufferSize

512 (bytes)

512-1500

NODE.osi.mainSetup.L1LSPBufferSize

512 (bytes)

512-1500

NODE.osi.mainSetup.NodeRoutingMode

Intermediate System Level 1

End System, Intermediate System Level 1, Intermediate System Level 1/Level 2

NODE.osi.subnet.ctc.DISPriority

63

1, 2, 3 .. 127

NODE.osi.subnet.ctc.ESH

10 (sec)

10, 20, 30 .. 1000

NODE.osi.subnet.ctc.GCCISISCost

60

1, 2, 3 .. 63

NODE.osi.subnet.ctc.IIH

3 (sec)

1, 2, 3 .. 600

NODE.osi.subnet.ctc.ISH

10 (sec)

10, 20, 30 .. 1000

NODE.osi.subnet.ctc.LANISISCost

20

1, 2, 3 .. 63

NODE.osi.subnet.ctc.LDCCISISCost

40

1, 2, 3 .. 63

NODE.osi.subnet.ctc.OSCISISCost

60

1, 2, 3 .. 63

NODE.osi.subnet.ctc.SDCCISISCost

60

1, 2, 3 .. 63

NODE.osi.tarp.L1DataCache

TRUE

FALSE, TRUE

NODE.osi.tarp.L2DataCache

FALSE

FALSE, TRUE

NODE.osi.tarp.LANStormSuppression

TRUE

FALSE, TRUE

NODE.osi.tarp.LDB

TRUE

FALSE, TRUE

NODE.osi.tarp.LDBEntry

5 (min)

1-10

NODE.osi.tarp.LDBFlush

5 (sec)

0-1440

NODE.osi.tarp.PDUsL1Propagation

TRUE

FALSE, TRUE

NODE.osi.tarp.PDUsL2Propagation

TRUE

FALSE, TRUE

NODE.osi.tarp.PDUsOrigination

TRUE

FALSE, TRUE

NODE.osi.tarp.T1Timer

15 (sec)

0-3600

NODE.osi.tarp.T2Timer

25 (sec)

0-3600

NODE.osi.tarp.T3Timer

40 (sec)

0-3600

NODE.osi.tarp.T4Timer

20 (sec)

0-3600

NODE.osi.tarp.Type4PDUDelay

0 (sec)

0-255

NODE.powerMonitor.EHIBATVG_48V

-56.5 (Vdc)

-40.5, -41.0, -41.5 .. -57.0

NODE.powerMonitor.EHIBATVG_60V

-72.0 (Vdc)

-50.0, -50.5, -51.0 .. -72.0

NODE.powerMonitor.ELWBATVG_48V

-40.5 (Vdc)

-40.5, -41.0, -41.5 .. -56.5

NODE.powerMonitor.ELWBATVG_60V

-50.0 (Vdc)

-50.0, -50.5, -51.0 .. -72.0

NODE.protection.Cisco ONS 15454.BidirectionalSwitching

FALSE

TRUE, FALSE

NODE.protection.lmsp.ReversionTime

5.0 (minutes)

0.5, 1.0, 1.5 .. 12.0

NODE.protection.lmsp.Revertive

FALSE

TRUE, FALSE

NODE.protection.msspr.RingReversionTime

5.0 (minutes)

0.5, 1.0, 1.5 .. 12.0

NODE.protection.msspr.RingRevertive

TRUE

TRUE, FALSE

NODE.protection.msspr.SpanReversionTime

5.0 (minutes)

0.5, 1.0, 1.5 .. 12.0

NODE.protection.msspr.SpanRevertive

TRUE

TRUE, FALSE

NODE.protection.splitter.ReversionTime

5.0 (minutes)

0.5, 1.0, 1.5 .. 12.0

NODE.protection.splitter.Revertive

FALSE

TRUE, FALSE

NODE.protection.ycable.ReversionTime

5.0 (minutes)

0.5, 1.0, 1.5 .. 12.0

NODE.protection.ycable.Revertive

FALSE

TRUE, FALSE

NODE.security.dataComm.ctc.DefaultTCCEthernetIP

10.0.0.1

IP Address

NODE.security.dataComm.ctc.DefaultTCCEthernetIPNetmask

24 (bits)

8, 9, 10 .. 32

NODE.security.dataComm.CtcBackplaneIpDisplaySuppression

(NOT SUPPORTED)

FALSE, TRUE when isSecureModeSupportedOnControlCard is TRUE

(NOT SUPPORTED) when isSecureModeSupportedOnControlCard is FALSE

NODE.security.dataComm.isSecureModeSupportedOnControlCard

FALSE

FALSE, TRUE

NODE.security.dataComm.LcdBackplaneIpSetting

(NOT SUPPORTED)

Allow Configuration, Display Only, Suppress Display when isSecureModeSupportedOnControlCard is TRUE

(NOT SUPPORTED) when isSecureModeSupportedOnControlCard is FALSE

NODE.security.dataComm.SecureModeLocked

(NOT SUPPORTED)

FALSE, TRUE when isSecureModeSupportedOnControlCard is TRUE

(NOT SUPPORTED) when isSecureModeSupportedOnControlCard is FALSE

NODE.security.dataComm.SecureModeOn (May reboot node)

(NOT SUPPORTED)

FALSE, TRUE when isSecureModeSupportedOnControlCard is TRUE

(NOT SUPPORTED) when isSecureModeSupportedOnControlCard is FALSE

NODE.security.emsAccess.AccessState

NonSecure

NonSecure, Secure

NODE.security.emsAccess.IIOPListenerPort (May reboot node)

57790 (port #)

0-65535

NODE.security.idleUserTimeout.Maintenance

01:00 (hours:mins)

00:00, 00:01, 00:02 .. 16:39

NODE.security.idleUserTimeout.Provisioning

00:30 (hours:mins)

00:00, 00:01, 00:02 .. 16:39

NODE.security.idleUserTimeout.Retrieve

00:00 (hours:mins)

00:00, 00:01, 00:02 .. 16:39

NODE.security.idleUserTimeout.Superuser

00:15 (hours:mins)

00:00, 00:01, 00:02 .. 16:39

NODE.security.lanAccess.LANAccess (May disconnect CTC from node)

Front & Backplane

No LAN Access, Front Only, Backplane Only, Front & Backplane

NODE.security.lanAccess.RestoreTimeout

5 (minutes)

0-60

NODE.security.legalDisclaimer.LoginWarningMessage

<html><center><b>WARNING</b></center>This system is restricted to authorized users for business purposes. Unauthorized<p>access is a violation of the law. This service may be monitored for administrative<p>and security reasons. By proceeding, you consent to this monitoring.

Free form field

NODE.security.other.DisableInactiveUser

FALSE

FALSE, TRUE

NODE.security.other.InactiveDuration

45 (days)

1, 2, 3 .. 99 when DisableInactiveUser is TRUE

45 (and N/A) when DisableInactiveUser is FALSE

NODE.security.other.PMClearingPrivilege

Provisioning

Provisioning, Superuser

NODE.security.other.SingleSessionPerUser

FALSE

TRUE, FALSE

NODE.security.passwordAging.EnforcePasswordAging

FALSE

TRUE, FALSE

NODE.security.passwordAging.maintenance.AgingPeriod

45 (days)

20-90

NODE.security.passwordAging.maintenance.WarningPeriod

5 (days)

2-20

NODE.security.passwordAging.provisioning.AgingPeriod

45 (days)

20-90

NODE.security.passwordAging.provisioning.WarningPeriod

5 (days)

2-20

NODE.security.passwordAging.retrieve.AgingPeriod

45 (days)

20-90

NODE.security.passwordAging.retrieve.WarningPeriod

5 (days)

2-20

NODE.security.passwordAging.superuser.AgingPeriod

45 (days)

20-90

NODE.security.passwordAging.superuser.WarningPeriod

5 (days)

2-20

NODE.security.passwordChange.CannotChangeNewPassword

FALSE

TRUE, FALSE

NODE.security.passwordChange.CannotChangeNewPasswordForNDays

20 (days)

20-95

NODE.security.passwordChange.NewPasswordMustDifferFromOldByNCharacters

1 (characters)

1-20

NODE.security.passwordChange.PreventReusingLastNPasswords

1 (times)

1-10

NODE.security.passwordChange.RequirePasswordChangeOnFirstLoginToNewAccount

FALSE

TRUE, FALSE

NODE.security.radiusServer.ctc.AccountingPort

1813 (port)

0-32767

NODE.security.radiusServer.ctc.AuthenticationPort

1812 (port)

0-32767

NODE.security.radiusServer.EnableNodeAsFinalAuthenticatorWhenAuthenticationEnabled

TRUE

FALSE, TRUE

NODE.security.serialCraftAccess.EnableCraftPort

TRUE

TRUE, FALSE

NODE.security.shellAccess.AccessState

NonSecure

Disabled, NonSecure, Secure

NODE.security.shellAccess.EnableShellPassword

FALSE

TRUE, FALSE

NODE.security.shellAccess.TelnetPort

23

23-9999

NODE.security.snmpAccess.AccessState

NonSecure

Disabled, NonSecure

NODE.security.tl1Access.AccessState

NonSecure

Disabled, NonSecure, Secure

NODE.security.userLockout.FailedLoginsAllowedBeforeLockout

5 (times)

0-10

NODE.security.userLockout.LockoutDuration

00:30 (mins:secs)

00:00, 00:05, 00:10 .. 10:00

NODE.security.userLockout.ManualUnlockBySuperuser

FALSE

TRUE, FALSE

NODE.timing.bits-1.AdminSSMIn

STU

G811, STU, G812T, G812L, SETS, DUS

NODE.timing.bits-1.AISThreshold

DUS

G811, STU, G812T, G812L, SETS, DUS

NODE.timing.bits-1.Coding

HDB3

HDB3, AMI when FacilityType is E1

N/A when FacilityType is 2MHz

AMI when FacilityType is 64kHz+8kHz

NODE.timing.bits-1.CodingOut

HDB3

HDB3, AMI when FacilityTypeOut is E1

N/A when FacilityTypeOut is 2MHz

AMI when FacilityTypeOut is 6MHz

NODE.timing.bits-1.FacilityType

E1

E1, 64kHz+8kHz, 2MHz

NODE.timing.bits-1.FacilityTypeOut

E1

E1, 6MHz, 2MHz

NODE.timing.bits-1.Framing

FAS+CAS+CRC

FAS+CRC, FAS+CAS, FAS+CAS+CRC, FAS, Unframed when FacilityType is E1

N/A when FacilityType is 2MHz

FAS+CRC, FAS+CAS, FAS+CAS+CRC, FAS, Unframed, Unframed-2Mhz when FacilityType is 64kHz+8kHz

NODE.timing.bits-1.FramingOut

FAS+CAS+CRC

FAS+CRC, FAS+CAS, FAS+CAS+CRC, FAS, Unframed when FacilityTypeOut is E1

N/A when FacilityTypeOut is 2MHz

FAS+CRC, FAS+CAS, FAS+CAS+CRC, FAS, Unframed, Unframed-2Mhz when FacilityTypeOut is 6MHz

NODE.timing.bits-1.Sa bit

4

4, 5, 6, 7, 8 when FacilityType is E1

N/A when FacilityType is 2MHz

N/A when FacilityType is 64kHz+8kHz

NODE.timing.bits-1.State

unlocked

unlocked, locked, disabled

NODE.timing.bits-1.StateOut

unlocked

unlocked, locked, disabled

NODE.timing.bits-2.AdminSSMIn

STU

G811, STU, G812T, G812L, SETS, DUS

NODE.timing.bits-2.AISThreshold

DUS

G811, STU, G812T, G812L, SETS, DUS

NODE.timing.bits-2.Coding

HDB3

HDB3, AMI when FacilityType is E1

N/A when FacilityType is 2MHz

AMI when FacilityType is 64kHz+8kHz

NODE.timing.bits-2.CodingOut

HDB3

HDB3, AMI when FacilityTypeOut is E1

N/A when FacilityTypeOut is 2MHz

AMI when FacilityTypeOut is 6MHz

NODE.timing.bits-2.FacilityType

E1

E1, 64kHz+8kHz, 2MHz

NODE.timing.bits-2.FacilityTypeOut

E1

E1, 6MHz, 2MHz

NODE.timing.bits-2.Framing

FAS+CAS+CRC

FAS+CRC, FAS+CAS, FAS+CAS+CRC, FAS, Unframed when FacilityType is E1

N/A when FacilityType is 2MHz

FAS+CRC, FAS+CAS, FAS+CAS+CRC, FAS, Unframed, Unframed-2Mhz when FacilityType is 64kHz+8kHz

NODE.timing.bits-2.FramingOut

FAS+CAS+CRC

FAS+CRC, FAS+CAS, FAS+CAS+CRC, FAS, Unframed when FacilityTypeOut is E1

N/A when FacilityTypeOut is 2MHz

FAS+CRC, FAS+CAS, FAS+CAS+CRC, FAS, Unframed, Unframed-2Mhz when FacilityTypeOut is 6MHz

NODE.timing.bits-2.Sa bit

4

4, 5, 6, 7, 8 when FacilityType is E1

N/A when FacilityType is 2MHz

N/A when FacilityType is 64kHz+8kHz

NODE.timing.bits-2.State

unlocked

unlocked, locked, disabled

NODE.timing.bits-2.StateOut

unlocked

unlocked, locked, disabled

NODE.timing.general.Mode

External

External, Line, Mixed

NODE.timing.general.ReversionTime

5.0 (minutes)

0.5, 1.0, 1.5 .. 12.0

NODE.timing.general.Revertive

FALSE

TRUE, FALSE


D.3.2.1  Time Zones

Table D-24 lists the time zones that apply for node time zone defaults. Time zones are expressed in terms of their relative relationships to Greenwich Mean Time (GMT).

Table D-24 Time Zones (ANSI and ETSI ) 

Time Zone (GMT +/- Hours)
Location(s)

GMT-11:00

Midway Islands, Samoa

GMT-10:00

Hawaiian Islands, Tahiti

GMT-09:00

Anchorage - Alaska

GMT-08:00

Pacific Time (US & Canada), Tijuana

GMT-07:00

Mountain Time (US & Canada)

GMT-07:00

Phoenix - Arizona

GMT-06:00

Central Time (US & Canada)

GMT-06:00

Mexico City

GMT-06:00

Costa Rica, Managua, San Salvador

GMT-06:00

Saskatchewan, Manitoba

GMT-05:00

Bogota, Lima, Quito

GMT-05:00

Eastern Time (US & Canada)

GMT-05:00

Havana

GMT-05:00

Indiana (US)

GMT-04:00

Asuncion

GMT-04:00

Caracas, La Paz, San Juan

GMT-04:00

Atlantic Time (Canada), Halifax, Saint John, Charlottetown

GMT-04:00

Santiago

GMT-04:00

Thule (Qaanaaq)

GMT-03:30

St. John's - Newfoundland

GMT-03:00

Brasilia, Rio de Janeiro, Sao Paulo

GMT-03:00

Buenos Aires, Georgetown

GMT-03:00

Godthab (Nuuk) - Greenland

GMT-02:00

Mid-Atlantic

GMT-01:00

Azores, Scoresbysund

GMT-01:00

Praia - Cape Verde

GMT 00:00

Casablanca, Reykjavik, Monrovia

GMT

Greenwich Mean Time

GMT 00:00

Dublin, Edinburgh, London, Lisbon

GMT+01:00

Amsterdam, Berlin, Rome, Stockholm, Paris

GMT+01:00

Belgrade, Bratislava, Budapest, Ljubljana, Prague

GMT+01:00

Brussels, Copenhagen, Madrid, Vienna

GMT+01:00

Sarajevo, Skopje, Sofija, Vilnius, Warsaw, Zagreb

GMT+01:00

West Central Africa, Algiers, Lagos, Luanda

GMT+01:00

Windhoek (Namibia)

GMT+02:00

Al Jizah, Alexandria, Cairo

GMT+02:00

Amman

GMT+02:00

Athens, Bucharest, Istanbul

GMT+02:00

Beirut

GMT+02:00

Cape Town, Harare, Johannesburg, Pretoria

GMT+02:00

Jerusalem

GMT+02:00

Kaliningrad, Minsk

GMT+03:00

Aden, Antananarivo, Khartoum, Nairobi

GMT+03:00

Baghdad

GMT+03:00

Kuwait, Riyadh

GMT+03:00

Moscow, St. Petersburg, Novgorod

GMT+03:30

Tehran

GMT+04:00

Abu Dhabi, Mauritius, Muscat

GMT+04:00

Aqtau, T'bilisi

GMT+04:00

Baku

GMT+04:00

Yerevan, Samara

GMT+04:30

Kabul

GMT+05:00

Chelyabinsk, Prem, Yekaterinburg, Ufa

GMT+05:00

Islamabad, Karachi, Tashkent

GMT+05:30

Calcutta, Mumbai, New Delhi, Chennai

GMT+05:45

Kathmandu

GMT+06:00

Almaty

GMT+06:00

Colombo, Dhaka, Astana

GMT+06:00

Novosibirsk, Omsk

GMT+06:30

Cocos, Rangoon

GMT+07:00

Bangkok, Hanoi, Jakarta

GMT+07:00

Krasnoyarsk, Norilsk, Novokuznetsk

GMT+08:00

Irkutsk, Ulaan Bataar

GMT+08:00

Beijing, Shanghai, Hong Kong, Urumqi

GMT+08:00

Perth

GMT+08:00

Singapore, Manila, Taipei, Kuala Lumpur

GMT+09:00

Chita, Yakutsk

GMT+09:00

Osaka, Sapporo, Tokyo

GMT+09:00

Palau, Pyongyang, Seoul

GMT+09:30

Adelaide, Broken Hill

GMT+09:30

Darwin

GMT+10:00

Brisbane, Port Moresby, Guam

GMT+10:00

Canberra, Melbourne, Sydney

GMT+10:00

Hobart

GMT+10:00

Khabarovsk, Vladivostok

GMT+10:30

Lord Howe Island

GMT+11:00

Honiara, Magadan, Soloman Islands

GMT+11:00

Noumea - New Caledonia

GMT+11:30

Kingston - Norfolk Island

GMT+12:00

Andyra, Kamchatka

GMT+12:00

Auckland, Wellington

GMT+12:00

Marshall Islands, Eniwetok

GMT+12:00

Suva - Fiji

GMT+12:45

Chatham Island

GMT+13:00

Nuku'alofa - Tonga

GMT+13:00

Rawaki, Phoenix Islands

GMT+14:00

Line Islands, Kiritimati - Kiribati


D.3.3  ETSI CTC Default Settings

Table D-25 lists the CTC-level default settings for the Cisco ONS 15454. Cisco provides the following user-configurable defaults for CTC.

Create circuits with the Route Automatically check box selected by default.

Create TL1-like circuits (instructs the node to create only cross-connects, allowing the resulting circuits to be in an upgradable state).

Choose a default network map (which country).

Table D-25 CTC Default Settings (ETSI) 

Default Name
Default Value
Default Domain

CTC.circuits.AutoRoute

TRUE

TRUE, FALSE

CTC.circuits.CreateLikeTL1

FALSE

TRUE, FALSE

CTC.network.Map

United States

-none-, Germany, Japan, Netherlands, South Korea, United Kingdom, United States