Table Of Contents
Connect the PC and Log into the GUI
NTP-21 Set Up Computer for CTC
DLP-47 Run the CTC Installation Wizard for Windows
DLP-48 Run the CTC Installation Wizard for UNIX
DLP-49 Set Up the Java Runtime Environment for UNIX
NTP-22 Set Up CTC Computer to Connect to the ONS 15454
DLP-51 Set Up a Windows PC for Craft Connection to an ONS 15454 Using DHCP
DLP-52 Set Up a Windows PC for Craft Connection to an ONS 15454 Using Automatic Host Detection
DLP-53 Set Up a Solaris Workstation for a Craft Connection to an ONS 15454
DLP-55 Set Up a Computer for a Corporate LAN Connection
DLP-56 Disable Proxy Service Using Internet Explorer (Windows)
DLP-57 Disable Proxy Service Using Netscape (Windows and UNIX)
DLP-58 Provision Remote Access to the ONS 15454
NTP-23 Log into the ONS 15454 GUI
DLP-59 Connect Computer to the ONS 15454
DLP-61 Create Login Node Groups
DLP-62 Add a Node to the Current Session or Login Group
Connect the PC and Log into the GUI
This chapter explains how to connect PCs and workstations to the Cisco ONS 15454 and how to log into Cisco Transport Controller (CTC) software, the Cisco ONS 15454 OAM&P user interface.
Before You Begin
This section lists the chapter procedures (NTPs). Turn to a procedure for applicable tasks (DLPs).
1. NTP-21 Set Up Computer for CTC—Complete this procedure if your PC or workstation has never been connected to an ONS 15454.
2. NTP-22 Set Up CTC Computer to Connect to the ONS 15454—After your PC or workstation is set up for CTC, complete this procedure to set up your computer to connect to the ONS 15454.
3. NTP-23 Log into the ONS 15454 GUI—Complete this procedure to log into CTC.
NTP-21 Set Up Computer for CTC
Step 1 If your computer is a Windows PC, complete the "DLP-47 Run the CTC Installation Wizard for Windows" task, then go to Step 4.
Step 2 If your computer is a UNIX workstation, complete the "DLP-48 Run the CTC Installation Wizard for UNIX" task.
Step 3 If your computer is a UNIX workstation and you installed the JRE in Step 2, complete the "DLP-49 Set Up the Java Runtime Environment for UNIX" task.
Step 4 When your PC or workstation is set up, complete the "NTP-22 Set Up CTC Computer to Connect to the ONS 15454" procedure.
DLP-47 Run the CTC Installation Wizard for Windows
Step 1 Verify that your computer has the following:
•Processor—Pentium II, 300 Mhz or faster
•RAM—128 MB
•Hard drive—2 GB is recommended. 50 MB of space must be available.
•Operating System—Windows 95, Windows 98, Windows NT 4.0, or Windows 2000
Note These requirements are guidelines. CTC performance will be faster if your computer has a faster processor and more RAM. Refer to the Cisco ONS 15454 Reference Manual for computer requirements needed for small, medium, and large ONS 15454 networks.
Step 2 Insert the Cisco ONS 15454 Release 3.3 software or documentation CD into your computer CD drive. The installation program begins running automatically. If it does not start, navigate to your computer's CD directory and double-click setup.exe.
The Cisco Transport Controller Installation Wizard displays the components that will be installed on your computer ( Figure 3-1).
Figure 3-1 Starting the Cisco Transport Controller Installation Wizard
Step 3 Click Next.
Step 4 For installation type, choose Typical to install all the components shown in Figure 3-1, or choose Custom if you only want to install some of the components.
Step 5 Click Next.
Step 6 If you selected the Custom in Step 4, select the CTC components you want to install by checking or unchecking the boxes, then click Next. If you selected Typical, skip this step.
Step 7 The directory where the installation wizard will install CTC online help is displayed. The default is C:\Program Files\Cisco\CTC\Documentation.
Step 8 If you want to change the CTC online help directory, type the new directory path in the Directory Name field, or click Browse to navigate to the directory. If you do not want to change the directory, skip this step.
Step 9 Click Next.
Step 10 Review the components that will be installed. If you want to change them, click Back. If you have an active CTC session (for example, you are running the setup program to install additional components), close CTC before going to the next step.
Step 11 Click Next.
An Installation Issues dialog box is displayed.
Step 12 Review the issues, then click OK. The InstallShield program begins the Netscape Communicator 4.73 Setup program.
Step 13 Complete the Netscape installation:
a. On the Netscape Communicator 4.73 Setup dialog box, click Next.
b. On the Software License Agreement dialog box, click Yes.
c. On the Setup Type dialog box, click Typical, then click Next.
Note If the Netscape installation hangs when installing RealPlayer G2, restart the CTC installation. When the Netscape installation begins, select Custom at Step c., then deselect RealPlayer, then continue.
d. On the Netscape Desktop Preferences Options dialog box, check the boxes that apply, then click Next.
e. On the Select Program Folder dialog box, click Next.
f. On the Start Copying Files dialog box, click Install. The program begins the Netscape installation.
g. On the Question dialog box, click No.
h. On the Information dialog box, click OK.
i. On the Restarting Windows dialog box, click No, I will restart later, then click OK.
Step 14 Close the Netscape Communicator directory window to display the Cisco Transport Controller Installation Wizard dialog box.
Step 15 On the CTC Installation Wizard dialog box, click Next. The Java 2 runtime environment installation begins.
Step 16 Complete the JRE installation:
a. On the Software License Agreement dialog box, click Yes.
b. On the Choose Destination Location dialog box, click Next.
c. On the Select Browser dialog box, click the Microsoft Internet Explorer and Netscape 6 checkboxes, then click Next.
When JRE installation is complete, the Cisco Transport Controller Installation Wizard dialog box is displayed.
Step 17 Click Next. The CTC online help is installed. When installed, the policy file selection is displayed.
Step 18 Choose the JRE policy file to modify:
•Choose User Policy File (default) to modify the policy file that applies only to your user profile. This file will not be overwritten if you upgrade or reinstall the JRE. If you are the only user who will access an ONS 15454 from the PC you are setting up, choose this option.
•Select System Policy File to modify the system JRE policy file. This policy file applies to all computer users. If more than one individual will use this computer to access the ONS 15454, choose this option. However, if you reinstall or upgrade the JRE, the system policy file is overwritten and you will need to run the CTC Installation Setup program again to modify it.
Step 19 Click Next.
Step 20 If you selected System Policy File in Step 18, complete the following steps. If you selected User Policy File, go to Step 21.
a. The System Policy File Update dialog box displays the default policy file location (C:\Program Files\JavaSoft\jre). If you installed the JRE in a different location, enter the new path in the Directory Name field. After entering the path, or if the default path is correct, click OK.
b. Click OK on the confirmation dialog box.
Step 21 Click Finish.
Step 22 To connect to the ONS 15454, restart your computer and complete the "NTP-22 Set Up CTC Computer to Connect to the ONS 15454" procedure.
DLP-48 Run the CTC Installation Wizard for UNIX
Step 1 Verify that your computer has the following:
•RAM—128 MB
•Hard drive—Verify that 50 MB of space is available.
•Operating System—Solaris 2.5.x or 2.6.x
Note These requirements are guidelines. CTC performance will be faster is your computer has a faster processor and more RAM. Refer to the Cisco ONS 15454 Reference Manual for computer requirements needed for small, medium, and large ONS 15454 networks.
Step 2 Change the directory, type:
cd /cdrom/cdrom0/
Step 3 From the techdoc454 CD directory, type:
./setup.bat
The Cisco Transport Controller Installation Wizard displays the components that will be installed on your computer ( Figure 3-1):
•Netscape Communicator 4.76
•Java Runtime Environment 1.3.1_02
•CTC Online Help
•Modify Policy File—the JRE java.policy file is modified to enable CTC to download files needed to run the Cisco Transport Controller when you connect to an ONS 15454.
Step 4 Click Next.
Step 5 For installation type, choose Typical to install all components, or choose Custom if you do not want to install all the components.
Step 6 Click Next.
Step 7 If you selected the Custom in Step 5, select the CTC components you want to install by checking or unchecking the boxes, then click Next. If you selected Typical, skip this step.
Step 8 The directory where the installation wizard will install CTC online help is displayed. The default is C:\Program Files\Cisco\CTC\Documentation. If you want to change the CTC online help directory, type the new directory path in the Directory Name field, or click Browse to navigate to the directory.
Step 9 Click Next.
Step 10 Review the components that will be installed. If you want to change them, click Back. If CTC is running (for example, you are reinstalling components) close CTC before going to the next step.
Step 11 Click Next. The InstallShield program begins the Netscape Communicator 4.76 Setup program.
Step 12 Complete the Netscape installation:
a. On the Netscape Communicator 4.76 Setup dialog box, click Next.
b. On the Software License Agreement dialog box, click Yes.
c. On the Setup Type dialog box, click Typical.
d. On the Netscape Desktop Preferences dialog box, check the boxes that apply, then click Next.
e. On the Program Folder, click Next.
f. On the Start Copying Files dialog box, click Install. The program begins the Netscape installation.
g. On the Question dialog box, click No.
Step 13 On the Cisco Transport Controller Installation Wizard dialog box, click Next. The Java 2 runtime environment installation begins.
Step 14 Complete the JRE installation:
a. On the Software License Agreement dialog box, click Yes.
b. On the Choose Destination Location dialog box, click Next.
c. On the Select Browser dialog box, click the Microsoft Internet Explorer and Netscape 6 checkboxes, then click Next.
The JRE is installed. When installation is complete, the Cisco Transport Controller Set Wizard dialog box is displayed.
Step 15 Click Next. The CTC online help is installed. When installed, the policy file selection is displayed.
Step 16 Choose the JRE policy file to modify:
•Choose User Policy File (default) to create a policy file that applies only to your user profile. This file will not be overwritten if you upgrade or reinstall the JRE. If you are the only computer user who will access an ONS 15454, choose this option.
•Select System Policy File to modify the system JRE policy file. This policy file applies to all computer users. If more than one individual will use this computer to access the ONS 15454, choose this option. However, if you reinstall or upgrade the JRE, the system policy file is overwritten and you will need to run the CTC Installation Setup program again to modify it.
Step 17 Click Next, then click Finish.
Note Be sure to record the names of the directories you choose for Netscape, JRE, and the online documentation.
Step 18 If your installation included the JRE (that is, you chose the Typical installation or selected JRE from the custom installation), go to "DLP-49 Set Up the Java Runtime Environment for UNIX" task.
Note The Java Runtime Environment (JRE) may require certain patches to run properly. The patch tar file can be found in the JRE/Solaris directory on the CD. Please read the JRE/Solaris/Solaris.txt file for more information. In addition to installing any needed patches, follow the procedures below to set up JRE for use with Cisco Transport Controller on your UNIX system.
DLP-49 Set Up the Java Runtime Environment for UNIX
Note In this task, [your JRE path] represents the destination directory you chose for the Java Runtime Environment during JRE installation. For example, if your JRE destination directory is /usr/bin/jre, substitute /usr/bin/jre, wherever [your JRE path] occurs. Also, in the following procedures, [your Netscape path] refers to the destination directory you chose for Netscape, and must be substituted with your actual Netscape destination directory path.
Note CTC requires that the location of xterm is also in your path. If you have, for some reason, moved xterm from its default location, /usr/openwin/bin, you must change all occurrences of /usr/openwin/bin in the procedures below to reflect the actual path where xterm exists on your system.
Step 1 Set up the environment variable:
a. If you are using the csh shell, edit the .cshrc file in your home directory by appending the file with the lines:
setenv JRE [JRE path]
setenv NETSCAPE [Netscape path]
setenv NPX_PLUGIN_PATH $JRE/j2re1_3_1_02/plugin/sparc/ns4
set path = ( /usr/openwin/bin $NETSCAPE $path )
b. If you are using the ksh or bash shell, edit the .profile file in your home directory by appending the file with the lines:
JRE=[your JRE path]
NETSCAPE=[your Netscape path]
NPX_PLUGIN_PATH=$JRE/j2re1_3_1_02/plugin/sparc/ns4
PATH=/usr/openwin/bin:$NETSCAPE:$PATH
export JRE NPX_PLUGIN_PATH PATH
Step 2 Set the JRE reference:
a. Run the Control Panel by typing:
[JRE path]/j2re1_3_0_02/bin/ControlPanel
b. Click the Advanced tab.
c. From the combo box, select [JRE path]/j2re1_3_1_02. If the JRE is not found, select other and enter the following in the Path text box:
[JRE path]/j2re1_3_1_02
d. Click Apply. Go to the "NTP-22 Set Up CTC Computer to Connect to the ONS 15454" procedure.
Note If you are running multiple shells, before your new environment variable will be set you may need to invoke the same shell for which you changed the initialization file (for example, if you added the environment variable to the .cshrc file, you must run your browser under the csh shell.
NTP-22 Set Up CTC Computer to Connect to the ONS 15454
Step 1 From Table 3-1, select the ONS 15454 connection type that you want to set up for your computer.
Note For initial shelf turn up, you must use a local craft connection to the ONS 15454.
Step 2 If you need to set up your computer for corporate LAN access, complete the "DLP-55 Set Up a Computer for a Corporate LAN Connection" task. If not, proceed to the next step.
Step 3 If you need to set up the computer for remote access, complete the "DLP-58 Provision Remote Access to the ONS 15454" task. If not, proceed to the next step.
Step 4 If you need to set up your computer for TL1 access, refer to the Cisco ONS 15454 and Cisco ONS 15327 TL1 Command Guide. If not, proceed to the next step.
Step 5 If you need to set up your computer for local craft connections, choose a task from Table 3-2.
Table 3-2 ONS 15454 Craft Connection Options
Local Craft Connection Task Description• DLP-53 Set Up a Solaris Workstation for a Craft Connection to an ONS 15454
Complete this task if:
•You will access nodes running CTC software releases before Release 3.3
•You will connect to one ONS 15454; if you will connect to multiple ONS 15454s, you may need to reconfigure your computer's IP settings each time you connect to an ONS 15454
•You need to access non-ONS 15454 applications such as ping and trace route
• DLP-51 Set Up a Windows PC for Craft Connection to an ONS 15454 Using DHCP
Complete this task if:
•The CTC computer is provisioned for DHCP
•The ONS 15454 has DHCP forwarding enabled and is connected to a DHCP server
• DLP-52 Set Up a Windows PC for Craft Connection to an ONS 15454 Using Automatic Host Detection
Complete this task if:
•You are connecting to a node that resides in a secure network employing the ONS 15454 proxy server
•All nodes that you will access are running software release Release 3.3
•You will connect to ONS 15454s at different locations and times
•You do not need to access a LAN or use non-ONS 15454 applications such as ping and gateway TL1
Step 6 After your computer is set up to connect to the ONS 15454, proceed to the "NTP-23 Log into the ONS 15454 GUI" procedure.
DLP-50 Set Up a Windows PC for Craft Connection to an ONS 15454 on the Same Subnet Using Static IP Addresses
Step 1 Verify the operating system that is installed on your computer:
a. From the Windows Start menu, choose Settings > Control Panel.
b. On the Control Panel window, double-click the System icon.
c. On the General tab of the System Settings window, verify that the Windows operating system is one of the following: Windows 95, Windows 98, Windows 2000, or Windows NT 4.0
Step 2 Complete the steps in Table 3-3 for the operating system installed on your PC.
Step 3 After you set up your PC, proceed to the "NTP-23 Log into the ONS 15454 GUI" procedure to log into the ONS 15454.
DLP-51 Set Up a Windows PC for Craft Connection to an ONS 15454 Using DHCP
Purpose
Use this task to set up your computer for craft connection to the ONS 15454 using DHCP (dynamic host configuration protocol).
Tools/Equipment
CAT-5 cable
Prerequisite Procedures
NTP-21 Set Up Computer for CTC
Required/As Needed
As needed
Onsite/Remote
Onsite
Caution You will not be able to connect to the ONS 15454 if DHCP forwarding is not enabled on the ONS 15454 or the ONS 15454 is not connected to a DHCP server. By default, DHCP forwarding is not enabled. If you are connecting to an ONS 15454 to perform initial shelf turnup, complete the "DLP-50 Set Up a Windows PC for Craft Connection to an ONS 15454 on the Same Subnet Using Static IP Addresses" task or the "DLP-52 Set Up a Windows PC for Craft Connection to an ONS 15454 Using Automatic Host Detection" task.
Step 1 Verify the operating system that is installed on your computer:
a. From the Windows Start menu, choose Settings > Control Panel.
b. On the Control Panel window, double-click the System icon.
c. On the General tab of the System Settings window, verify that the Windows operating system is one of the following: Windows 95, Windows 98, Windows 2000, or Windows NT 4.0.
Step 2 Complete the steps in Table 3-4 for the operating system installed on your PC.
Step 3 After you set up your PC, go to the "NTP-23 Log into the ONS 15454 GUI" procedure to log into the ONS 15454.
DLP-52 Set Up a Windows PC for Craft Connection to an ONS 15454 Using Automatic Host Detection
Note This procedure employs the ONS 15454 automatic host detection to allow you to directly connect to multiple ONS 15454s successively without reconfiguring your computer's IP address. However, if proxy server is not enabled on the ONS 15454, DCC-connected nodes on different subnets will not be visible. Refer to the "NTP-26 Set Up Network Information" procedure on page 4-5 and the IP Networking chapter in the Cisco ONS 15454 Reference Manual for more information about the proxy server.
Step 1 Verify the operating system that is installed on your computer:
a. From the Windows Start menu, choose Settings > Control Panel.
b. On the Control Panel window, double-click the System icon.
c. On the General tab of the System Settings window, verify that the Windows operating system is one of the following: Windows 95, Windows 98, Windows 2000, or Windows NT 4.0
Step 2 Complete the steps in Table 3-5 for the operating system installed on your PC.
Table 3-5 Set Up Windows PC for Craft ONS 15454 Connections Using Automatic Host Detection
For Windows 95/98: For Windows NT: For Windows 2000:1. From the Windows Start menu, choose Settings > Control Panel.
2. On the Control Panel dialog box, click the Network icon.
3. In the Network dialog box select TCP/IP for your PC Ethernet card, then click Properties.
4. On the TCP/IP Properties dialog box, click the DNS Configuration tab and choose Disable DNS.
5. Click the WINS Configuration tab and choose Disable WINS Resolution.
6. Click the IP Address tab.
7. In the IP Address window, click Specify an IP address.
8. In the IP Address field, enter a legitimate IP address.
9. In the Subnet Mask field, type 255.255.255.0.
10. Click OK.
11. On the TCP/IP dialog box, click the Gateway tab.
12. In the New Gateway field, type your PC IP address (the address entered in Step 6.). Click Add.
13. Verify that the IP address displays in the Installed Gateways field, then click OK.
14. When the prompt to restart your PC displays, click Yes.
1. From the Windows Start menu, choose Settings > Control Panel.
2. On the Control Panel dialog box, click the Network icon.
3. In the Network dialog box click the Protocols tab, choose TCP/IP Protocol, then click Properties.
4. Click the IP Address tab.
5. In the IP Address window, click Specify an IP address.
6. In the IP Address field, enter a legitimate IP address.
7. In the Subnet Mask field, type 255.255.255.0.
8. Click the Advanced button.
9. Under the Gateways List, click Add. The TCP/IP Gateway Address dialog box is displayed.
10. Type the IP address entered in
Step 6. in the Gateway Address field.11. Click Add.
12. Click OK.
13. Click Apply.
14. In some cases, Windows NT will prompt you to reboot your PC. If you receive this prompt, click Yes.
1. From the Windows Start menu, choose Settings > Network and Dial-up Connections > Local Area Connection.
2. On the Local Area Connection Status dialog box, click Properties.
3. On the General tab, choose Internet Protocol (TCP/IP), then click Properties.
4. Click Use the following IP address.
5. In the IP Address field, enter a legitimate IP address.
6. In the Subnet Mask field, type 255.255.255.0.
7. Type the IP address entered in
Step 5. in the Gateway Address field.8. Click OK.
9. On the Local Area Connection Status dialog box, click Close.
10. On the Local Area Connection Properties dialog box, click OK.
Step 3 After you set up your PC, you can go to the "NTP-23 Log into the ONS 15454 GUI" procedure to log into the ONS 15454.
DLP-53 Set Up a Solaris Workstation for a Craft Connection to an ONS 15454
Purpose
Use this task to set up a Solaris workstation for a craft connection to the ONS 15454.
Tools/Equipment
None
Prerequisite Procedures
Required/As Needed
As needed
Onsite/Remote
Onsite
Step 1 Log into the workstation as the root user.
Step 2 Check to see if the interface is plumbed by typing:
# ifconfig <device>
For example: # ifconfig hme1
a. If the interface is plumbed, a message similar to the following appears: hme1:flags=1000842<BROADCAST,RUNNING,MULTICAST,IPv4>mtu 1500 index 2 inet 0.0.0.0 netmask 0. Go to Step 4.
b. If the interface is not plumbed, a message similar to the following appears: ifconfig: status: SIOCGLIFFLAGS: hme1: no such interface. Plumb the interface by typing:
# if config <device> plumb
For example: ifconfig hme1 plumb
Step 3 Configure the IP address on the interface by typing:
#ifconfig <interface> <ip address> netmask <netmask> up
For example: #ifconfig hme0 10.20.30.40 netmask 255.255.255.0 up
Note Enter an IP address that is identical to the ONS 15454 IP address except for the last three digits. The last three digits must be between 1 and 254. In the Subnet Mask field, type 255.255.255.0. Skip this step if "Craft Access Only" from Provisioning > Network > General > Gateway Settings is checked.
Step 4 Test the connection:
a. Start Netscape Navigator or Internet Explorer.
b. Enter the Cisco ONS 15454 IP address in the web address (URL) field. If the connection is established, a Java Console window, CTC caching messages, and the Cisco Transport Controller Login dialog box display. If this occurs, go to Step 2 of the "DLP-60 Log into CTC" task to complete the login. If the Login dialog box does not appear, complete Steps c- d.
c. At the prompt, type:
ping [ONS 15454 IP address]
For example, you would type "ping 192.168.1.1" to connect to an ONS 15454 with default IP address 192.168.1.1. If your workstation is connected to the ONS 15454, an "[IP address] is alive" message displays.
Note Skip this step if "Craft Access Only" from Provisioning > Network > General > Gateway Settings is checked.
d. If CTC is not responding, a "Request timed out" message displays. Verify IP and submask information. Check that the cables connecting the workstation to the ONS 15454 are securely attached. Check the Link Status by typing:
#ndd -set /dev/<device> instance 0
#ndd -get /dev/<device> link_status
For example:
#ndd -set /dev/hme instance 0
#ndd -get /dev/hme link_status
The result of 1 means the link is up. The result of 0 means the link is down.
Note Check the man page for ndd. For example: #man ndd
Step 5 After you set up your workstation, proceed to the "NTP-23 Log into the ONS 15454 GUI" procedure to log into the ONS 15454.
DLP-55 Set Up a Computer for a Corporate LAN Connection
Purpose
Use this task to set up your computer to access the ONS 15454 through a corporate LAN.
Tools/Equipment
None
Prerequisite Procedures
Required/As Needed
As needed
Onsite/Remote
Onsite or remote
Step 1 If your computer is connected to the corporate LAN, go to Step 2. If you changed your computer's network settings for craft access to the ONS 15454, change the settings back to the corporate LAN access settings. This generally means:
•Set the IP Address on the TCP/IP dialog box back to "Obtain an IP address automatically" (Windows 95/98) or "Obtain an IP address from a DHCP server" (Windows NT/2000).
•If your LAN requires that DNS or WINS be enabled, change the setting on the DNS Configuration or WINS Configuration tab of the TCP/IP dialog box.
Step 2 If your computer is connected to a proxy server, disable proxy service or add the ONS 15454 nodes as exceptions. To disable proxy service, complete the task for the web browser you use:
• DLP-56 Disable Proxy Service Using Internet Explorer (Windows), or
• DLP-57 Disable Proxy Service Using Netscape (Windows and UNIX)
DLP-56 Disable Proxy Service Using Internet Explorer (Windows)
Step 1 From the Start menu, select Settings > Control Panel.
Step 2 In the Control Panel window, choose Internet Options.
Step 3 From the Internet Properties dialog box, click Connections > LAN Settings.
Step 4 On the LAN Settings dialog box, either:
•Deselect Use a proxy server to disable the service, or
•Leave Use a proxy server selected and click Advanced. On the Proxy Setting dialog box under Exceptions, enter the IP addresses of ONS 15454 nodes that you will access. Separate each address with a semicolon. You can insert an asterisk for the host number to include all the ONS 15454s on your network. Click OK to close each open dialog box.
Step 5 Proceed to the "NTP-23 Log into the ONS 15454 GUI" procedure to log into the ONS 15454.
DLP-57 Disable Proxy Service Using Netscape (Windows and UNIX)
Step 1 Open Netscape.
Step 2 From the Edit menu, choose Preferences.
Step 3 In the Preferences dialog box under Category, choose Advanced > Proxies.
Step 4 On the right side of the Preferences dialog box under Proxies, either:
•Choose Direct connection to the Internet to bypass the proxy server
or
•Choose Manual proxy configuration to add exceptions to the proxy server, then click View. On the Manual Proxy Configuration dialog box under Exceptions, enter the IP addresses of the ONS 15454 nodes that you will access. Separate each address with a comma. Click OK to close each open dialog box.
Step 5 Proceed to the "NTP-23 Log into the ONS 15454 GUI" procedure to log into the ONS 15454.
DLP-58 Provision Remote Access to the ONS 15454
.
Step 1 Connect the modem to the RJ-45 port on the TCC+ or to the LAN pins on the ONS 15454 backplane.
Step 2 Refer to the modem documentation to provision the modem for the ONS 15454:
•For CTC access, set the modem for Ethernet access.
•Assign an IP address to the modem that is on the same subnet as the ONS 15454.
•The IP address the modem assigns to the CTC computer must be on the same subnet as the modem and the ONS 15454.
Note For assistance on provisioning specific modems, contact the Cisco Technical Assistance Center, at 1-877-323-7368.
Step 3 Proceed to the "NTP-23 Log into the ONS 15454 GUI" procedure to log into the ONS 15454.
NTP-23 Log into the ONS 15454 GUI
Purpose
Use this procedure to log into the Cisco Transport Controller, the graphical user interface software used to manage the ONS 15454. This procedure includes optional node login tasks.
Tools/Equipment
None
Prerequisite Procedures
NTP-21 Set Up Computer for CTC
Required/As Needed
Required to access the Cisco Transport Controller
Onsite/Remote
Onsite or remote
.
Step 1 If the computer is not connected to the ONS 15454, complete the "DLP-59 Connect Computer to the ONS 15454" task.
Step 2 Complete the "DLP-60 Log into CTC" task for instructions.
Note For information about navigating in CTC, see Appendix A.
Step 3 As needed, complete the "DLP-61 Create Login Node Groups" task. Login node groups display nodes that are not connected to the log-in node via DCC.
Step 4 As needed, complete the "DLP-62 Add a Node to the Current Session or Login Group" task.
Step 5 Turn to the table of contents, list of procedures, or index to locate any other procedures that you need to perform for your site.
DLP-59 Connect Computer to the ONS 15454
Purpose
Use this task to connect a CTC computer to the ONS 15454.
Tools/Equipment
CAT-5 cable
Prerequisite Procedures
NTP-21 Set Up Computer for CTC
Required/As Needed
Required to access the Cisco Transport Controller
Onsite/Remote
Onsite or remote
.
Step 1 If your computer is set up for a local craft connection, connect a CAT-5 cable from the PC or Solaris workstation NIC card to one of the following:
•The RJ-45 port on the TCC+
•The RJ-45 port on a hub or switch to which the ONS 15454 is physically connected
Note For instructions on crimping your own CAT-5 cables, refer to the Cisco ONS 15454 Troubleshooting Guide.
Step 2 If your computer is set up for a corporate LAN connection, connect a CAT-5 cable from the PC or Solaris workstation NIC card to a LAN port.
Step 3 Continue to the "DLP-60 Log into CTC" task.
DLP-60 Log into CTC
Purpose
Use this task to log into the Cisco Transport Controller, the graphical user interface software used to manage the ONS 15454.
Tools/Equipment
None
Prerequisite Procedures
NTP-21 Set Up Computer for CTC
Required/As Needed
Required
Onsite/Remote
Onsite or remote
Note For information about CTC views and navigation, see Appendix A.
Step 1 From the PC connected to the ONS 15454, start Netscape or Internet Explorer.
Step 2 In the Netscape or Internet Explorer Web address (URL) field, enter the ONS 15454 IP address. For initial setup, this is the default address, 192.1.0.2. Press Enter.
Note If you are logging into ONS 15454 nodes running different releases of CTC software, log into the node running the most recent release. If you log into a node with an older release, you receive an INCOMPATIBLE-SW alarm and the IP address of the login node will display instead of the node name. To check the software version of a node, select About CTC from the CTC Help menu. To resolve an alarm, refer to the Cisco ONS 15454 Troubleshooting Guide.
A Java Console window displays the CTC file download status. The web browser displays information about your Java and system environments. If this is the first login, CTC caching messages display while CTC files are downloaded to your computer. The first time you connect to an ONS 15454, this process can take several minutes. After the download, the CTC Login dialog box displays ( Figure 3-2).
Figure 3-2 Logging into CTC
Step 3 In the Login dialog box, type a user name and password (both are case sensitive). For initial setup, type the user name "CISCO15" if it is not already displayed.
Note The CISCO15 user is provided with every ONS 15454. CISCO15 has superuser privileges, so you can create other users. CISCO15 is delivered without a password. To create one, click the Provisioning > Security tabs after you log in and change the CISCO15 password. (You cannot delete the CISCO15 user.) To set up ONS 15454 users and assign security, go to the "NTP-30 Create Users and Assign Security" procedure on page 4-27. Additional information is provided in the Cisco ONS 15454 Reference Guide.
Step 4 Each time you log into an ONS 15454, you can make selections on the following login options:
•Node Name—Displays the IP address entered in the web browser and a pull-down menu of previously-entered ONS 15454 IP addresses. You can select any ONS 15454 on the list for the login, or you can enter the IP address (or node name) of any new node where you want to log in.
•Additional Nodes—Displays a list of login node groups that were created. To create a login node group or add additional groups, see the "DLP-61 Create Login Node Groups" task.)
Note Topology hosts that were created in previous ONS 15454 releases by modifying the ctc.ini file are displayed as a "Topology Host" group under Additional Nodes.
•Exclude Dynamically Discovered Nodes—Check this box to view only the ONS 15454 (and login node group members, if any) entered in the Node Name field. Nodes linked to the Node Name ONS 15454 through the DCC are not displayed. Using this option can decrease the CTC startup time in networks with many DCC-connected nodes.
Step 5 Click Login.
If login is successful, the CTC window displays. From here, you can navigate to other CTC views to provision and manage the ONS 15454. If you need to perform the initial shelf turn up, go to Chapter 4, "Turn Up Shelf." If login problems occur, refer to the Cisco ONS 15454 Troubleshooting Guide.
DLP-61 Create Login Node Groups
Purpose
Create a login node group to display ONS 15454s that have an IP connection but not a DCC connection to the login node.
Tools/Equipment
None
Prerequisite Procedures
NTP-21 Set Up Computer for CTC
Required/As Needed
As needed
Onsite/Remote
Onsite or remote
Step 1 Log into an ONS 15454 on the network. See the "DLP-60 Log into CTC" task for instructions.
Step 2 From the Edit menu, choose Preferences.
Step 3 Click the Login Node Group tab and click Create Group.
Step 4 Enter a name for the group in the Create Login Group Name dialog box. Click OK.
Step 5 Under Members, type the IP address (or node name) of a node you want to add to the group. Click Add. Repeat this step for each node you want to add to the group.
Step 6 Click OK.
The next time you log into an ONS 15454, the login node group will be available in the Additional Nodes list of the Login dialog box. For example, in Figure 3-3, a login node group, "Test Group," is created and the IP addresses for Nodes 1, 4, and 5. During login, if you select Test Group under Additional Nodes, all nodes in the figure are displayed. You can create as many login groups as you need. The groups are stored in the CTC preferences file and are not visible to other users.
Figure 3-3 A login node group
DLP-62 Add a Node to the Current Session or Login Group
Purpose
Use this task to add a node to the current CTC session or login node group.
Tools
None
Prerequisite Procedures
None
Required/As Needed
As needed
Onsite/Remote
Onsite or remote
Step 1 Log into an ONS 15454 on the network. See the "DLP-60 Log into CTC" task for instructions.
Step 2 From the CTC File menu, click Add Node (or click the Add Node button on the toolbar).
Step 3 On the Add Node dialog box, enter the node name (or IP address).
Step 4 If you want to add the node to the current login group, click Add Node to Current Login Group. Otherwise, leave it unchecked.
Note The Add Node to Current Login Group checkbox is active only if you selected a login group when you logged into CTC.
Step 5 Click OK.
After a few seconds, the new node will be displayed on the network view map.
Posted: Fri Feb 22 17:38:17 PST 2008
All contents are Copyright © 1992--2008 Cisco Systems, Inc. All rights reserved.
Important Notices and Privacy Statement.