cc/td/doc/product/ong/15305/305docs
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table Of Contents

Dual Optical S-1.1 Module

14.1 Functional Description of Module

14.2 Power Consumption

14.3 External STM-1 S-1.1 Interface

14.4 Connector Type

14.5 Optical Budget

14.6 Compliance


Dual Optical S-1.1 Module


14.1 Functional Description of Module

The S1.1-2-LC module contains two optical STM-1 interfaces that meet the S-1.1 specification in ITU-T G.957. The physical connector is an LC connector.

14.2 Power Consumption

The power consumption of the S1.1-2-LC module is 9 W.

14.3 External STM-1 S-1.1 Interface

The two optical STM-1 interfaces use dual fiber interface, LC style connector, one fiber in each direction, 1310nm wavelength and use single mode fiber of type 10/125 um. The optical interfaces is compatible with ITU-T 957 for S-1.1.

The interface is an optical STM-1 short haul interface, according to clause 5 ITU-T G.957 The definitions of optical parameters and reference points S and R refer to ITU-T G.957. Reference point S refers to the transmit direction and R refers to the receive direction of the fiber.

14.4 Connector Type

The physical connector is a LC connector.

Figure 14-1 S1.1-2-LC Module

14.5 Optical Budget

Table 14-1 S-1.1 Interface Optical Budget

Parameter
Value

Modulation rate on optical line

155 520 kbps

Wavelength range

1261 - 1360 nm

Transmitter at reference point S
 

Source type

MLM

Spectral characteristics (max. RMS width)

7.7 nm

Mean launched power (max.)

-8 dBm

Mean launched power (min.)

-15 dBm

Min. extinction ratio

8.2 dB

Optical path between S and R
 

Attenuation range

0 - 12 dB

Max. tolerable dispersion

96 ps/nm

Min. optical return loss

NA

Max. discrete reflectance between S and R

NA

Receiver at reference point R
 

Min. sensitivity (BER < 1 in 1010)

-28 dBm

Min. overload

-8 dBm

Max. optical path penalty

1 db

Max. reflectance at R

NA


14.6 Compliance

Table 14-2 Optical S-1.1 Interface Compliance

Standard
Comment

ITU-T G.652

Type of optical fiber

ITU-T G.707

Optical line signal

ITU-T G.783

RX pull-in and hold range

ITU-T G.813

Optical output jitter

ITU-T G.825

Optical input jitter

ITU-T G.957

Optical spectrum

Optical output power

Optical eye diagram

Optical extinction ratio

ITU-T G.958

Input jitter measurement



hometocprevnextglossaryfeedbacksearchhelp

Posted: Fri Sep 14 11:03:21 PDT 2007
All contents are Copyright © 1992--2007 Cisco Systems, Inc. All rights reserved.
Important Notices and Privacy Statement.