Table Of Contents
13.1 Functional Description of Module
High-Density 63xE1 Module
13.1 Functional Description of Module
The E1-63 module contains 63 E1 interfaces. The E1 traffic is mapped into VC-12 containers and multiplexed together according to the "5.1.1Multiplexing Structure and Mapping Modes" section on page 5-1.
Two high-density LFH type connectors are used to interface the 63 E1s; 32 interfaces in the bottom connector and 31 interfaces in the top connector (one pair left unconnected)
This module supports transparent data (G.703) and ISDN PRA.
Figure 13-1 High Density 63xE1 Module, E1-63
13.2 Power Consumption
The power consumption of the E1-63 module is 8 W.
13.3 Connectors
The connector is a high-density LFH connector.
13.4 Compliance
13.5 Patch Panels
Patch panels and an LFH cable are available for patching the 63 E1s interface on the High Density 63xE1 module.
13.5.1 32XE1 LFH - LFH Cable
Figure 13-2 32XE1 LFH - LFH Cable
The available patch cable length is 3 M.
13.5.2 32xE1-LFH-RJ45 panel
Figure 13-3 32xE1-LFH-RJ45 panel