cc/td/doc/product/ong/15216/flexlayr
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table Of Contents

Introduction


Introduction


This document describes the Cisco ONS 15216 FlexLayer Asymmetric DWDM network equipment and provides a detailed overview of the new features that are either directly visible to the end user or are important to understanding the equipment operation.

All components are optically passive and require no electrical connections.

The Cisco ONS 15216 FlexLayer Asymmetric DWDM release includes the following components:

Eight channel add or drop flex module

Two channel add or drop flex module

Optical splitter or combiner flex module (2, 3, and 4 channels)

Four channel VOA flex module

FlexLayer shelf assembly.

The FlexLayer modules use Y-cable protection modules. These modules are:

Multimode Y cable protection module

Single mode Y cable protection module

The FlexLayer features include:

200km of total fiber length or 3600 ps/nm of total fiber dispersion

82 dB (20+2x22+18) maximum point to point loss with optical amplification and no regeneration

25 dB maximum point to point loss without optical amplification and no regeneration.

Unidirectional TX only

Protected pt-pt application

Protected hubbed rings, 16 Nodes, 2 с 32 Channel per Node

Unprotected pt-pt application

32 channels + 1 OSC channel

OSC support for management connectivity

Optical drop with 2 channel granularity

NEBS 3E

Compatible to operate on ITU-T G652 Single Mode Fiber (SMF28 or equivalent)