This chapter describes how to use the Maintenance Manager to view and modify the configuration of the Client Layer Interface Port (CLIP) modules.

3.1 Clip Inventory

The Clip Inventory screen provides information about the selected CLIP module. The Clip Inventory screen is divided into four areas: General, Board, RX transponder, and TX transponder. There are no editable fields on the Module Inventory screen.

3.1.1 General

The General area of the Clip Inventory screen displays inventory information about the entire CLIP module (Figure 3-1). See Table 3-1for general parameters.


Table 3-1:
Clip Inventory Screen - General
Parameter Definition

Network Element Id

Displays the ID of the network element (NE).

ITU Channel

Displays the channel where the CLIP module is configured to operate. Channels are defined according to the standard ITU grid.

Full DCN Address

Defines the Data Control Network address assigned to this module.

CLIP Part No

Displays the Cisco part number for the CLIP module.

CLIP Serial No

Displays the Cisco serial number for the CLIP module.

CLEI code

Displays the CLEI code for the selected module.

NEC Part No

Displays the Network Element Controller part number.

FW Revision No

Displays the revision number of the firmware.


Figure 3-1:
Clip Inventory screen


3.1.2 Board

The Board area of the Clip Inventory screen displays inventory information about the main circuit board on the CLIP module (Figure 3-1). See Table 3-2 for Board parameters.


Table 3-2:
Clip Inventory Screen - Board
Parameter Definition

Board Part No

Displays the part number assigned to the CLIP module main circuit board.

Board Serial No

Displays the serial number of the CLIP module main circuit board.

3.1.3 Rx Transponder

The Rx Transponder area of the Clip Inventory screen displays inventory information about the Rx transponder submodule on the CLIP module (Figure 3-1). See Table 3-3 for Rx Transponder parameters.


Table 3-3:
Clip Inventory Screen - Rx Transponder
Parameter Definition

RxTP Type

Displays the type of Rx transponder installed on the selected CLIP module. The Type definition is divided into these parts.

  • Client laser nominal optical power

  • Level of signal regeneration (3R)

  • ADP

  • Protected or unprotected

RxTP Part No

Displays the Cisco part number of the Rx transponder module installed on the selected CLIP module.

RxTP Serial No

Displays the serial number of the Rx transponder module installed on the selected CLIP module.

3.1.4 Tx Transponder

The Tx Transponder area of the Clip Inventory screen displays inventory information about the Tx transponder submodule on the CLIP module (Figure 3-1). See Table 3-4 for Tx Transponder parameters.


Table 3-4:
Clip Inventory Screen - Tx Transponder
Parameter Definition

TxTP Type

Displays the type of Tx transponder installed on the selected CLIP module. The TxTP Type definition has these parts:

  • Transmitted optical power

  • Level of signal regeneration (3R)

  • Protected or unprotected

TxTP Production No

Displays the Cisco part number of the Tx transponder module installed on the selected CLIP module.

TxTP Revision No

Displays the revision of the Tx transponder module installed on the selected CLIP module.

TxTP Serial No

Displays the serial number of the Tx transponder module installed on the selected CLIP module.

3.2 Clip Summary

The Clip Summary screen displays the configuration of the selected CLIP module (Figure 3-2). The Clip Summary screen is divided into three areas. The General area displays the operating state of the CLIP module and the data rate. The DWDM Side area describes the alarm status of the DWDM side, the optical paths, the optical coupling ratio, and the switch mode.

The information available on the Summary screen varies, depending on whether the Summary screen is associated with a CLIP module configured as protected or unprotected. Figure 3-2 shows the Summary screen for a protected CLIP. The Summary screen for unprotected clip modules does not show the Switch Mode or Standby Path fields.

The following fields on the Summary screen can be edited by the operator:


Figure 3-2: Clip Summary screen


3.2.1 General

The General area of the Clip Summary screen describes general parameters that apply to the CLIP module. The values for the Data Rate field can be changed by the operator. Table 3-5 describes the parameters found in the General area of the CLIP Module Summary screen.


Table 3-5:
CLIP Module Summary Screen - General
Parameter Value

Network Element Status

  • Uninit - The Maintenance Manager did not recieve any information from the selected CLIP module.

  • Normal - The selected CLIP module has not reported any alarms.

  • Warning - The selected CLIP module has reported a condition that exceeds a high warning or lower warning threshold value.

  • Minor - The selected CLIP module generated a minor alarm based on a condition that exceeds a high alarm or lower alarm threshold value.

  • Major - The selected CLIP module generated a major alarm based on a condition that exceeds a high alarm or lower alarm threshold value.

  • Critical - The selected CLIP module generated a critical alarm based on a condition that exceeds a high alarm or lower alarm threshold value.

Data Rate

Describes the rate at which data is being transmitted in and by the ONS 15200 system. The operator can change this value. The "Changing the Data Rate" section describes the procedure for changing the data rate.

3.2.2 Changing the Data Rate

Follow these steps to change the data rate for the selected CLIP module:


Step 1   Open the Clip Summary screen and double-click the Data Rate value. The Set Value screen opens (Figure 3-3).

Step 2   Select the desired data rate from the list. Table 3-5 describes the data rate selections available.

Step 3   Click OK. The selected data rate appears on the Clip Summary screen. The change is effective immediately.

The procedure for changing the data rate is complete.


Figure 3-3: Set Value (datarate) window



Table 3-6: Data Rate Values
Parameter Value

OC-3/STM-1

The selected CLIP module will transmit at the bit rate of 155 Mbps.

OC-12/STM-4

The selected CLIP module will transmit at the bit rate of 622 Mbps.

OC-48/STM-16

The selected CLIP module will transmit at the bit rate of 2.5 Gbps.

Gigabit Ethernet

The selected CLIP module will transmit data at the rate of approximately 1.25 Gbps.

3.2.3 DWDM Side

The DWDM Side area of the Clip Summary screen describes parameters that apply to the ONS 15200 transmissions between CLIP modules. The values for the Switch Mode field can be changed by the operator. Table 3-7 describes the DWDM Side parameters.


Table 3-7:
Clip Summary Screen - DWDM SIde
Parameter Value

DWDM Status

  • Normal - The selected CLIP module has not reported any alarms.

  • Warning - The selected CLIP module has reported a condition that exceeds a high warning or lower warning threshold value.

  • Minor - The selected CLIP module generated a minor alarm based on a condition that exceeds a high alarm or lower alarm threshold value.

  • Major - The selected CLIP module generated a major alarm based on a condition that exceeds a high alarm or lower alarm threshold value.

  • Critical - The selected CLIP module generated a critical alarm based on a condition that exceeds a high alarm or lower alarm threshold value.

Switch Mode

Displays the switching scheme assigned to the selected CLIP module. The operator can change this value.

The switching scheme selected determines how the ONS 15200 system will behave if the input signal is lost on the active path. Section 3.2.4 describes the procedure for changing the switching scheme.

Active Path

Displays the primary path on which the CLIP module is receiving. In protected configurations, the active path can be either path_a or path_b.

Standby Path

(protected channel only)

Displays the secondary path on which the CLIP module is receiving. In the event of a disruption on the primary path, the system uses the signal received on the standby path. The standby path is always the opposite of the active path, if it exists.

Note When switch mode is set to either forced_a or forced_b, there is no alternative standby signal. The system is forced to use either the a or b path.

Optical Coupling Ratio

Describes how the optical power is split between the A side and the B side of the system.

In a protected system the following values are available:

  • a90b10-90% of the optical power is allocated to the A side and 10% of the optical power is allocated to the B side.

  • a50b50-50% of the optical power is allocated to the A side and 50% of the optical power is allocated to the B side.

  • a10b90-10% of the optical power is allocated to the A-side and 90% of the optical power is allocated to the B side.

In an unprotected system the following values are available:

  • a100b0-100% of the optical power is allocated to the A side and 0% of the optical power is allocated to the B side.

  • a0b100-0% of the optical power is allocated to the A side and 100% of the optical power is allocated to the B side.

3.2.4 Changing the Switch Mode


Note Switch mode is only available on protected channels.

Follow these steps to change the switch mode for the selected CLIP module:


Step 1   On the Clip Summary screen double-click the switchmode value (Figure 3-2). The Set Value window opens (Figure 3-4).


Figure 3-4: Set Value (dwdm.switchmode) window


Step 2   Select the desired switch mode from the list. Table 3-8 describes the selections available.

Step 3   Click OK. The value appears on the Clip Summary screen. The changes are effective immediately.


Table 3-8:
Switch Mode Values
Parameter Value

cond_a

Automatically selects path A as the primary path if the signal on the A side is present. If the signal is lost and power is present on the B side, the path switches. However, as soon as the A-side signal returns, the signal reverts to the A side.

cond_b

Automatically selects path B as the primary path if the signal on the B side is present. If the signal is lost and power is present on the A side, the path switches. However, as soon as the B side signal returns, the signal reverts to the B side.

forced_a

Forces traffic to the A side.

forced_b

Forces traffic to the B side.

automatic

Automatically switches traffic to the standby path when the active path input signal is lost. The switch is non-revertive.

3.2.5 Client Side

The Client Side area of the Clip Summary screen describes parameters that apply to the ONS 15200 transmissions between the selected CLIP module and the client equipment. Values in this section cannot be modified by the operator. Table 3-9 describes the Client Side parameters.


Table 3-9:
CLIP Module Summary Screen - Client Side
Measurement Definition

Client Alarm Status

  • Normal - The selected CLIP module has not reported any alarms.

  • Warning - The selected CLIP module has reported a condition that exceeds a high warning or lower warning threshold value.

  • Minor - The selected CLIP module generated a minor alarm based on a condition that exceeds a high alarm or lower alarm threshold value.

  • Major - The selected CLIP module generated a major alarm based on a condition that exceeds a high alarm or lower alarm threshold value.

  • Critical - The selected CLIP module generated a critical alarm based on a condition that exceeds a high alarm or lower alarm threshold value.

3.3 Clip Status

The Clip Status screen displays the operating status of the CLIP module (Figure 3-5). Table 3-10 describes the parameters found in this screen.


Table 3-10: CLIP Module Status Screen Values
Parameter Definition

Name

Displays the name of the measurement.

Suppress Alarm

Contains a checkbox to select or deselect the Suppress Alarm feature.

Status

Describes the status of the alarm. The following values are possible:

  • Normal - The selected CLIP module has not reported any alarms.

  • Uninit - The Maintenance Manager did not recieve any information from the selected CLIP module.

  • Lowalarm - The CLIP module recorded an event that exceeded the lower alarm threshold for the selected parameter.

  • Lowwarning - The CLIP module recorded an event that exceeded the lower warning threshold for the selected parameter.

  • Suppressed - The selected parameter will not report its status. (Also indicated by a selected Suppress Alarm checkbox.)

  • Highwarning - The CLIP module recorded an event that exceeded the high warning threshold for the selected parameter.

  • Highalarm - The CLIP module recorded an event that exceeded the high alarm threshold for the selected parameter.

Low Alarm

Displays the lower threshold value that will cause an alarm to be generated.

Low Warning

Displays the lower threshold value that will cause a warning to be generated.

Present Value

Displays the real-time value of the parameter as measured by the module.

High Warning

Displays the upper threshold value that will cause a warning to be generated.

High Alarm

Displays the upper threshold value that will cause an alarm to be generated.

Unit

Displays the unit of measure for the values of the selected parameter.

The Clip Status screen is divided into four areas: DWDM Side, Client Side, Environment, and DCN. The DWDM Side area lists the settings and current values of the signal from the DWDM side of the ONS 15200 system. Parameters listed in the Client Side area describes the quality of the signal received from the client equipment. The Environment area provides the board temperature and power of the CLIP module. The DCN area indicates any Control Area Network (CAN) or QPP alarms.

The information available on the Status screen varies, depending on whether the associated CLIP module is configured as protected or unprotected. Figure 3-5 shows the Status screen for a protected CLIP. The Status screen for unprotected CLIP modules does not show the B Rx Power field.

For each parameter, the following fields can be modified:


Figure 3-5: Clip Status screen


3.3.1 Suppressing Alarms

Follow these steps to configure alarms and warnings so they are not reported.

Caution Suppressing alarms can be service affecting.

Step 1   Select the Suppress Alarms checkbox for the alarm or warning you want to suppress. A check mark appears in the box.

Step 2   To configure the alarm to report, clear the checkbox.

The procedure to suppress alarms is complete.

3.3.2 Setting Threshold Values

Follow these steps to set the CLIP module threshold available on the Clip Status screen:


Step 1   Double-click the desired threshold value. The Set Value window appears.

Step 2   Type the desired value.

Step 3   Click OK. The new threshold value takes effect immediately.

The procedure for setting threshold values is complete.

3.3.3 DWDM Side

The DWDM Side area of the Clip Status screen describes how the CLIP module is operating in relation to the MCU and SCUs that make up the ONS 15200 network (Figure 3-5). Values for A RX Power, B RX Power, Peltier Current, Laser Temperature, and Laser Bias are listed in this section. Table 3-11 describes the optical network parameters.


Table 3-11:
Clip Status - DWDM Side
Parameter Definition

A RX Power

(protected channels only)

Displays the values associated with the strength of the signal received from the A-side MCU or SCU.

B RX Power

(protected channels only)

Displays the values associated with the strength of the signal received from the B-side MCU or SCU.

RX Power

(non-protected channels only)

Displays the values associated with the strength of the received signal.

Peltier Current

Displays the values associated with the strength of the current to the Peltier device. The Peltier device regulates the temperature of the laser and maintains the wavelength of the transmitted signal.

Laser Temperature

Displays the values associated with the temperature of the laser that transmits to the SCUs and MCU in the ONS 15200 network.

Laser Bias

Displays the laser bias current for the selected CLIP module.

Figure 3-6 shows the RX and TX power measurement points for the optical network interfaces on a CLIP module.


Figure 3-6: CLIP module RX and TX points


3.3.4 Client Side

The Client Side area of the Clip Status screen describes how the CLIP module is operating in relation to the client equipment attached to the ONS 15200 system. Values for Client RX Power and Laser Bias are listed on this screen. Table 3-12 describes the client access parameters.


Table 3-12:
Clip Status - Client Side
Parameter Definition

Client RX Power

Displays the strength of the signal received from the client equipment attached to the ONS 15200 network.

Laser Bias

Displays the laser bias current for the selected CLIP module.

3.3.5 Environment

The Environment area of the Clip Status screen provides the Board Temperature and Power parameters for the CLIP module. Table 3-13 describes the Environment parameters.


Table 3-13:
Clip Status - Environment
Parameter Definition

Board Temperature

Displays the values associated with the ambient temperature on the surface of the CLIP module.

Power

Displays the status of the input power coming into the SCU or MCU from the AC to DC converter.

3.3.6 DCN

The DCN area of the Clip Status screen provides the CAN bus and QPP signal status. Table 3-14 describes the DCN parameters.


Table 3-14:
Clip Status - DCN
Parameter Definition

CAN alarm

Displays the status of the CAN bus.

QPP A alarm
(protected only)

Displays the transmission status of the internal datacom link on the A side of the network.

QPP B alarm
(protected only)

Displays the transmission status of the internal datacom link on the B side of the network.

QPP alarm
(unprotected only)

Displays the transmission status of the internal datacom link of the network.

3.4 Path Folder Overview

The Path Folder Overview screen provides a graphical representation of the optical paths configured for the ONS 15200 network (Figure 3-7). LEDs indicate active alarms on the NE. The signal direction is indicated by the lines entering or exiting the NE. Green lines indicate inbound signals and white lines indicate outbound signals. A red line indicates inbound signals that have alarms somewhere on the path.


Figure 3-7: Path Folder Overview screen


The Path Summary screen provides an operational summary of the selected path (Figure 3-8). The Path Summary screen is divided into two sections. The upper part is similar to the Path Folder Overview screen (Figure 3-7) and the lower part shows an extract of the Clip Summary screen
(Figure 3-8).


Figure 3-8: Circuit Path Summary screen