Table of Contents
Connectors and Cabling
5.1 Electrical Connectors
5.2 Optical Fiber Jumper Cable Connectors
Connectors and Cabling
This chapter contains line assignments for electrical and optical cables. For specific optical configurations, consult your network planner.
5.1 Electrical Connectors
Caution Static electricity can damage electro-optical equipment. While unpacking and handling electro-optical modules, wear a properly grounded wrist strap to discharge the static buildup. Grounding wrist straps are designed to prevent equipment damage caused by static electricity. Before making the necessary interconnections, connect the grounding wrist strap to a tested earth ground.
5.1.1 ONS 15252 MCU Electrical Connectors
Table 5-1 shows CIM MA connections.
Table 5-1 ONS 15252 CIM Management Access Connections
Pin Number
Function
Signal
1
RxD
EIA/TIA-232 receive
2
GND
0 VDC reference for EIA/TIA-232 and CAN bus
3
CANL_RET
CAN bus return (low) from MA system
4
CANH_RET
CAN bus return (high) from MA system
5
CANH
CAN bus (high) to MA system
6
CANL
CAN bus (low) to MA system
7
TERM_INSERT
+4.5 VDC, 72 ohms (reserved, part of the CAN bus control)
8
TxD
EIA/TIA-232 transmit
Table 5-2 shows the CIM internal bus (INT BUS) connections.
Table 5-2 ONS 15252 CIM I nternal Bus Connections
Pin Number
Function
Signal
1
Floating
Reserved, part of the CAN bus termination control
2
Floating
Reserved, part of the CAN bus termination control
3
CANH
CAN bus (high)
4
CANL
CAN bus (low)
5
GND
0 VDC
6
LINE_INSERT
+4.5 VDC, 145 ohms (reserved, part of the CAN bus termination)
Table 5-3 shows ONS 15252 MCU power supply connections.
Table 5-3 ONS 15252 MCU Power Supply Connections
Connector
Pin Number
Voltage
PS-1
1
0 VDC
PS-1
2
-48 VDC
PS-2
1
0 VDC
PS-2
2
-48 VDC
5.1.2 ONS 15201 SCU Electrical Connectors
Table 5-4 shows ONS 15201 internal bus (INT BUS) connections.
Table 5-4 ONS 15201 Internal Bus Connections
Pin Number
Function
Signal
1
Floating
Reserved, part of the CAN bus termination control
2
Floating
Reserved, part of the CAN bus termination control
3
CANH
CAN bus (high)
4
CANL
CAN bus (low)
5
GND
0 VDC
6
LINE_INSERT
+4.5 VDC, 145 ohms (reserved, part of the CAN bus termination control)
Table 5-5 shows management access (MA) connections.
Table 5-5 ONS 15201 Management Access Connections
Pin Number
Function
Signal
1
NA
Not used
2
GND
0 VDC reference for CAN bus and part of CAN bus relay control
3
CANL_RET
CAN bus return (low) from MA system
4
CANH_RET
CAN bus return (high) from MA system
5
CANH
CAN bus (high) to MA system
6
CANL
CAN bus (low) to MA system
7
TERM_INSERT
+4.5 VDC, 72 ohms (reserved, part of the CAN bus control)
8
NA
Not used
Table 5-6 shows ONS 15201 SCU power supply connections.
Table 5-6 ONS 15201 SCU Power Supply Connections
Connector
Pin Number
Voltage
PS-1
1
-48 VDC
PS-1
2
0 VDC
PS-1
3
-48 VDC
PS-1
4
0 VDC
PS-2
1
-48 VDC
PS-2
2
0 VDC
PS-2
3
-48 VDC
PS-2
4
0 VDC
Table 5-7 shows ONS 15201 alarm cable connections.
Table 5-7 ONS 15201 Alarm Cable Connections
Pin Number
Function
Signal
1
NC
Normally closed
2
NO
Normally open
3
C
Common
4
C
Common
5
NO
Normally open
6
NC
Normally closed
5.2 Optical Fiber Jumper Cable Connectors
Note Inspect and clean optical connectors prior to making optical connections. Unused optical connectors
should have plugs inserted.
5.2.1 ONS 15252 MCU Optical Connectors
Optical connections in the ONS 15252 MCU are listed in Table 5-8 . For specific optical configurations, consult with your network planner.
Table 5-8 ONS 15252 MCU Optical Connections
Connector
Connection
Client IN (All CLIP modules)
Client input signal (toward the ONS 15252 MCU)
Client OUT (All CLIP modules)
Client output signal (from the ONS 15252 MCU)
NAM A-side IN
A-side DWDM input signal (toward the 15216 MUX/DEMUX or OADM)
NAM A-side out
A-side DWDM output signal (from the 15216 MUX/DEMUX or OADM
NAM B-side IN
B-side DWDM input signal (toward the 15216 MUX/DEMUX or OADM
NAM B-side out
B-side DWDM output signal (from the 15216 MUX/DEMUX or OADM
5.2.2 ONS 15201 SCU Optical Connectors
Table 5-9 lists optical connections for the ONS 15201 SCU.
Table 5-9 ONS 15201 SCU Optical Connections
Connector
Connection
Client IN
Client input signal (toward the ONS 15201 SCU)
Client OUT
Client output signal (from the ONS 15201 SCU)
A-side SCU IN
A-side DWDM add signal (toward the ONS 15201 SCU)
A-side SCU OUT
A-side DWDM drop signal (from the ONS 15201 SCU)
B-side SCU IN
B-side DWDM add signal (toward the ONS 15201 SCU)
B-side SCU OUT
B-side DWDM drop signal (from the ONS 15201 SCU)