This chapter provides instructions for installing Cisco 15200 units, which include assembled-to-order Cisco 15252 Multichannel Units (MCUs) and individual MCU components, and assembled-to-order ONS 15201 Single-Channel Units (SCUs) and individual SCU components. This chapter also explains how to install a new channel on an MCU and how to link multiple nodes to accommodate additional traffic.


Note   The instructions in this section primarily address the installation of the ONS 15252 MCUs, ONS 15201 SCUs, and modules supplied by Cisco Systems. When installing racks, electrical wiring, raceways, and other equipment not covered in this manual, you should follow all local, state, federal, or international (if applicable) codes and regulations.

3.1  Installation Overview

You should be thoroughly familiar with the instructions in this manual before starting any work. Use the following general order of work when installing a site:


Step 1   Read and observe all safety cautions and warnings in "Safety Summary."

Step 2   When you arrive at the site, first verify the ONS 15200 equipment according to the procedures in "Pre-Installation Procedures." If there is a problem with the equipment, contact the Cisco Technical Assistance Center (TAC) at 1-877-323-7368.

Step 3   If you do not install the equipment when it arrives, store as specified in "Pre-Installation Procedures."

Step 4   Unpack equipment only after preparing the site as described in "Pre-Installation Procedures."

Step 5   When installing equipment at a site, follow the procedures in this chapter in the order presented.

Step 6   Turn up and test the ONS 15200 system as described in "Turn Up and Test."

Step 7   Make connections using the information in "Connectors and Cabling."


3.2  Installation Planning

Based on the system to be installed, determine the size, number, and location of racks, as well as the MCUs and SCUs required. The MCUs and SCUs will fit in 485 mm (19-in.) equipment racks, and can be adapted for 584 mm (23-in.) racks. The racks must be accessible from the front and rear for equipment installation.


Note   If you do not have rear access to the equipment, you must install the ground and power on the equipment before mounting the equipment in a rack.

Plan rack and unit installation based on the following considerations:

3.2.1  Required Items

To install an ONS 15200 system, customary installation and electrical tools are required. The following items are also required:

Chapter 4 lists the items required for turn up and test.

3.2.2  Installation Guidelines

When installing ONS 15200 equipment into racks, follow these guidelines:

Figure 3-1 shows the outer dimensions of the ONS 15200 system equipment.


Figure 3-1: Outer dimensions (mm and in.) of the ONS 15200 system equipment


3.2.3  Grounding Considerations

It is vital that the ONS 15252 MCU, ONS 15252 fan unit, and ONS 15201 SCU are properly grounded. The grounding points on the ONS 15200 units are located as follows:

The location of the grounding points on the MCU and SCU is shown in Figure 3-2. The location of the fan unit grounding points is shown in Figure 3-3.


Figure 3-2: Ground points on the ONS 15252 MCU and ONS 15201 SCU



Figure 3-3:
Ground points on the ONS 15252 fan unit


3.2.4  Power Considerations

The ONS 15252 MCU, ONS 15252 fan unit, and ONS 15201 SCU can be powered with a regular telecommunication power supply of -48 VDC (and 0 VDC return). AC powering can be made from the regular power grid, at both 115 VAC and 230 VAC, through the use of AC-to-DC power converters. Two independent power supplies can be attached to the ONS 15200 equipment. If two different supplies are used, they should be independently powered.


Caution   Do not use the AC cord that can be ordered for the SCU in cable management devices such as wiring ducts, plenums, or risers. For such applications, you must provide an approved AC power cord. At minimum, the AC power cord must meet all National Electrical Code (NFPA 70, National Electrical Code, 2000 Edition) standards and all local building code requirements. This applies to Central Offices and other buildings.

3.2.5  Shelf Version Considerations

Two versions of the ONS 15252 MCU mechanical shelf exist: Release 1.0 and Release 1.0.1. Cisco currently ships only the Release 1.0.1 shelf and no longer ships the Release 1.0 shelf.

The Release 1.0.1 shelf includes a baffle. The baffle is a partially-perforated, angled metal plate that is mounted below and behind the metal support beam, and is mechanically attached to the back of the shelf. It runs the width of the shelf. To view the baffle, look up through the ventilation cavities at the back of the shelf.

The ONS 15252 Release 1.0.1 includes a fan unit. Before using the Release 1.0.1 shelf, you must install the fan unit. Do not use the fan unit with a Release 1.0 shelf. See the Cisco ONS 15200 Product Description for more information about the fan unit.


Caution   You must install the fan unit in a Release 1.0.1 shelf. Cisco does not recommend or support running the Release 1.0.1 shelf without the fan unit. Equipment damage may occur.


Caution   Do not install the fan unit in a Release 1.0 shelf. Cisco does not recommend or support running the Release 1.0 shelf with a fan unit. Equipment damage may occur.

The ONS 15252 Release 1.0.1 includes an updated Network Adaptation module (NAM). The Release 1.0.1 NAM is designated with a "NEBS-3 compliant" label on the faceplate, whereas the previous version of the NAM does not have a faceplate label. The Release 1.0.1 shelf requires the Release 1.0.1 NAM. You can also use Release 1.0.1 NAMs in the Release 1.0 shelf. See the Cisco ONS 15200 Module Handbook for more information about the NAM.


Caution   Cisco does not recommend or support placing NAMs without the "NEBS-3 compliant" label into an Release 1.0.1 shelf. Equipment damage may occur.

3.3  Fiber Cleaning

You will need a Cletop cleaning kit (type A for SC and type B for MU fiber connectors) to clean the fiber connectors and adapters before installing fiber.


Caution   Clean the fibers before use to prevent equipment damage.

Procedure: Clean Fiber Connectors


Warning Invisible laser radiation may be emitted from the end of the unterminated fiber cable or connector. Do not stare into the beam or view directly with optical instruments.


Step 1   Remove the dust cap from the fiber connector.

Step 2   Insert the connector into the Cletop cleaning cassette slot, rotate one quarter turn, and gently swipe downwards.

Step 3   Insert the fiber connector into the applicable adapter.

Step 4   Place dust caps on the fiber connectors when not in use.


Procedure: Clean Fiber Adapters


Step 1   Remove the dust plug from the fiber adapter.

Step 2   Insert a cleaning stick into the adapter opening.

Step 3   To access the male connector in the adapter, loosen the two screws that attach the metal cover to the CLIP, and remove the metal cover.

Step 4   Clean the male connector in the fiber adapter.

Step 5   Place dust plugs on the fiber adapters when not in use.


3.4  ONS 15252 MCU Assembled-to-Order Installation

Use the following procedures to install an assembled-to-order (ATO) ONS 15252 MCU. Prior to installing an MCU in an equipment rack, verify that at least 13 rack units (578 mm [22.8 in.]) of space is available. The lower portion of the MCU is the passive optical shelf.

You can also install the MCU using extension brackets, included in the MCU accessory kit, to convert a 485 mm (19-inch) rack to a 584.2 mm (23-inch) rack.

The ATO MCU contains a Release 1.0.1 shelf. See the "Shelf Version Considerations" procedure.


Note   An ATO MCU comes equipped with two Termination modules (TMs). The Bridge module (BM) is delivered as a separate item.

Procedure: Mount the ONS 15252 MCU in an Equipment Rack


Note   You can install the ground and power cables before mounting the MCU. See the "Install the ONS 15252 MCU Ground Cable" procedure and the "Connect the ONS 15252 MCU A-side and B-side Power Connections to the PDP" procedure for more information.


Caution   During the ONS 15252 MCU installation, two people are required to lift and hold the unit in position.


Step 1   Align eight M6 cage nuts in the equipment rack. Figure 3-4 shows an example of an equipment rack, with the cage nuts shaded in gray.


Figure 3-4: Aligning the ONS 15252 MCU with the rack cage nuts


Step 2   Lift and align the MCU with the equipment rack and cage nuts. The mounting holes in the MCU should align with the cage nuts.

Step 3   Attach the MCU to the equipment rack with eight screws (M6 or UNC 12-24).

Step 4   Mount the cable ties (item 51-2587-01 in the accessory kit) to the racks, immediately outside the opening in the hinged lid cover. You will use the cable ties to manage the cable in the "Install the ONS 15252 MCU Fiber Cable" procedure.


Procedure: Mount the ONS 15252 MCU in an Equipment Rack Using Extension Brackets

The shelf assembly comes preset for installation in a 485 mm (19-in.) rack, but you can use extension brackets to convert it to a 584.2 mm (23-in.) rack. You will need two 13 RU extension brackets (P/N: 700-13268) for this procedure.


Caution   During the ONS 15252 MCU installation, two people are required to lift and hold the unit in position.


Step 1   Align the indented edge of one of the extension brackets with the equipment rack.

Step 2   Attach the indented edge of the extension bracket to the equipment rack with the mounting screws (UNC 12-24) provided with the panel adapter.

Step 3   Repeat Steps 1 and 2 for the second extension bracket.

Step 4   Once the extension brackets are secure, lift and align the MCU with the mounting holes.

Step 5   Attach the MCU to the extension brackets with eight screws (M6 or UNC 12-24).

Figure 3-5 shows the extension brackets attached to the equipment rack.


Figure 3-5: Attached extension brackets


Step 6   Mount the cable ties (item 51-2587-01 in the accessory kit) to the racks. You will use the cable ties to manage the cable in the "Install the ONS 15252 MCU Fiber Cable" procedure.

Procedure: Remove the ONS 15252 MCU Transport Crossbeam from the Passive Optical Shelf Door


Step 1   Open the passive optical shelf door.

Step 2   Locate the three left-side crossbeam mounting screws.

Step 3   Use a Phillips screwdriver to remove the crossbeam mounting screws from the left side. Figure 3-6 shows the location of the screws on the left side.


Figure 3-6: Removing the crossbeam screws


Step 4   Locate the three crossbeam mounting screws on the right side. Use a Phillips screwdriver to remove the crossbeam mounting screws from the right side.

Step 5   When the left- and right-side crossbeam mounting screws are removed, lift and remove the crossbeam from the passive optical shelf door.


Note   Keep the transport crossbeam and the screws stored in a safe location for possible retrieval and reinstallation in case the equipment is moved to another location.


Procedure: Install the ONS 15252 MCU Fan Unit

You must install a fan unit in the equipment rack above each ONS 15252 MCU.


Caution   You must install the fan unit in a Release 1.0.1 shelf. Cisco does not recommend or support running the Release 1.0.1 shelf without the fan unit. Equipment damage may result. For more information about shelf versions, see the "Shelf Version Considerations" procedure.


Caution   Do not install the fan unit in a Release 1.0 shelf. Cisco does not recommend or support running the Release 1.0 shelf with a fan unit. Equipment damage may result. For more information about shelf versions, see the "Shelf Version Considerations" procedure.


Step 1   Insert the fan unit in the equipment rack. See the hole pattern for the fan unit in Figure 3-4. Figure 3-7 shows the fan unit.


Figure 3-7: Fan unit


Step 2   Use four screws (M6 or UNC 12-24) to connect the fan unit to the equipment rack.

Step 3   Connect the power to the two fan unit -48 VDC power inputs located on the far right (primary) and far left (secondary) of the fan-unit back panel (Figure 3-8):


Figure 3-8:
Power and ground points on the ONS 15252 fan unit


Step 4   Install the ground cable (P/N 72-3526). A pair of grounding pins (M4 screws) is located beside each of the power connectors on the fan-unit back panel (Figure 3-8). You must connect the grounding cable to one of the pairs of screws. Choose the pair that is the most convenient connection point for your installation. You can use either a single or double lug (see Figure 3-9).


Figure 3-9: Ground cable lugs (single and double)


Step 5   Connect the fan unit to an external alarm panel (if applicable). Connect the alarm panel cable (P/N 74-2603) to the 6-pole [P/N AMP 0-176125-6] connector on the front of the fan unit.


Caution   The maximum power for a signal line is 24 V DC/300mA. Do not exceed this level when interfacing between an external alarm panel and the fan unit.

Step 6   Once you have installed the fan unit, verify the following:


Procedure: Replace the Filter in the Fan Unit

You can replace the filter in the fan unit without removing the fiber organizer. Replacing the filter does not affect traffic.


Warning Do not insert your fingers into the fan tray while the fans are running.


Note   Remove and visually inspect the fan-unit filter every six months. If necessary, replace the old filter with a new filter (P/N 700-12955).


Step 1   Turn the screws one quarter-turn counter clockwise.

Step 2   Slide the filter frame out from the fan unit, as shown in Figure 3-10.


Figure 3-10: Removing the filter frame


Step 3   Lift up one of the ends of the metal bands that secure the filter.

Step 4   Remove the old filter.

Step 5   Place the new filter in the filter frame.

Step 6   Mount the metal bands by entering the two back extensions into the back of the filter frame and the right extension into the right of the frame. Bend the remaining left metal band extension under the frame.

Step 7   Slide the filter frame back into the fan unit.

Step 8   Lock the filter frame by turning the screws one quarter-turn clockwise.


Procedure: Install the Fiber Organizer In Front of the Fan Unit

The fiber organizer uses the same four screws (M6 or UNC 12-24) that are used to secure the fan unit.


Step 1   Remove any screws that obstruct the mounting of the fiber organizer (Figure 3-4).

Step 2   Align the fiber organizer with its four mounting holes (Figure 3-4).

Step 3   Insert and tighten the four screws to connect the fiber organizer to the fan unit and equipment rack.


3.4.1  Install the ONS 15252 MCU Ground Cable

The following procedures describe how to ground an ONS 15252 MCU. The lug on the ONS 15252 MCU ground cable can be either a single or dual lug as shown in Figure 3-11. You can also ground the MCU using the ground strip (P/N 72-2755) shown in Figure 3-12.


Figure 3-11: Ground cable lugs (single and double)



Figure 3-12:
Ground strip


Procedure: Install an ONS 15252 MCU Single-Lug Ground Connection


Step 1   Remove one M6 nut and washer from one of the grounding pins located on either side of the MCU backplane.

Step 2   Route the ground cable to the grounding pin where the M6 nut and washer were removed.

Step 3   Attach the ground cable to the grounding pin using the M6 nut and washer removed in Step 1.

Step 4   Use a socket wrench to firmly tighten the M6 nut on the grounding pin. The attached ground cable should look similar to the one shown in Figure 3-13.


Figure 3-13: Attaching a single-lug ground cable


Step 5   Connect the other end of the ground cable to the ground window.

Step 6   Use a multimeter that is set to read ohms to test the ground connection. The display on the multimeter should be less than 5 ohms. If the display is more than 5 ohms, tighten or reconnect the ground connection and test it again.


Procedure: Install an ONS 15252 MCU Dual-Lug Ground Connection


Step 1   Remove the M6 nut and washer from two of the grounding pins located on either side of the MCU.

Step 2   Route the ground cable to the grounding pins where the M6 nuts and washers were removed.

Step 3   Attach the ground cable to the grounding pins using the M6 nuts and washers removed in Step 1.

Step 4   Use a socket wrench to firmly tighten the M6 nuts on the grounding pins. The attached ground cable should look like the one in Figure 3-14.


Figure 3-14: Attaching a dual-lug ground cable


Step 5   Connect the other end of the ground cable to the ground window.

Step 6   Use a multimeter that is set to read ohms to test the ground connection. The display on the multimeter should be less than 5 ohms. If the display is more than 5 ohms, tighten or reconnect the ground connection and test again.


Procedure: Install an ONS 15252 MCU Ground Strip Connection


Step 1   Remove one M6 nut and washer from one of the grounding pins located on either side of the MCU backplane.

Step 2   Route the ground strip to the grounding pin where the M6 nut and washer were removed.

Step 3   Attach the ground strip to the grounding pin with the M6 nut and washer removed in
Step 1 .

Step 4   Use a socket wrench to firmly tighten the M6 nut on the grounding pin.

Step 5   Connect the other end of the ground strip to the equipment rack.

Step 6   Use a multimeter that is set to read ohms to test the ground connection. The display on the multimeter should be less than 5 ohms. If the display is more than 5 ohms, tighten or reconnect the ground connection and test it again.


3.4.2  Install the ONS 15252 MCU Power

The following procedure explains how to install ONS 15252 power connections.

Procedure: Connect the ONS 15252 MCU A-side and B-side Power Connections to the PDP


Warning Before installing power to the ONS 15252 MCU, remove the fuses from both the A and B sides of the battery distribution bay (BDB) and power distribution panel (PDP). Failure to do so can result in injury or death. Determine the actual wire gauge based on local engineering standards and practices.


Warning To prevent equipment damage and injury, do not reverse the polarity of the PDP-to-ONS 15252 MCU power connections.


Step 1   Remove the A- and B-side fuses from the BDB and the PDP.

Step 2   Connect the MCU power cable to the B side of the PDP. Be sure the poles are correct when you connect the power cable.

Step 3   Insert the power cables into the connector and tighten the wire retaining screws.

Step 4   Align and connect the power cable to the PS-2 (Power Supply 2) connector (left side) on the MCU backplane as shown in Figure 3-15.

Step 5   Tie-wrap the power cable to the MCU as shown in Figure 3-15.


Figure 3-15: Connecting power to the ONS 15252 MCU


Step 6   Connect the MCU power cable to the A side of the PDP. Be sure the poles are correct.

Step 7   Insert the power cables into the connector and tighten the wire retaining screws.

Step 8   Align and connect the power cable with the PS-1 connector (right side) on the MCU backplane.

Step 9   Tie-wrap the power cable to the MCU.

Step 10   Reinsert the A-side and B-side BDB and PDP fuses.

Step 11   Verify that A- and B-side -48 VDC and -48 VDC return (0 VDC) of the MCU are connected to the proper poles at the power source. The -48 VDC return must be connected to ground the PDP on both the A and B sides.

Step 12   Verify that the incoming power is within the range of -42 VDC to -56 VDC before applying power.

Step 13   Install the Network Control Board (NCB) and Communication Interface module (CIM) temporarily to determine if the ONS 15252 MCU has power. The LEDs on the CIM and NCB are green when the MCU has power.


Note   To obtain an accurate LED reading, do not insert an NCB in a CLIP slot while the corresponding NAM is inserted. You must first remove the corresponding NAM if you want to insert the NCB in a CLIP slot.


3.4.3  Install the ONS 15252 MCU Fiber Cable


Caution   Always use the supplied electrostatic discharge (ESD) wristband when working with an ONS 15252 MCU.

The ONS 15252 MCU Client Layer Interface Port (CLIP) modules and the DWDM interface port use SC fiber connectors.

To install fiber-optic cables in the ONS 15252, connect a fiber cable with the corresponding connector type to the transmit and receive ports on the CLIP and the DWDM interface. On a CLIP module, the transmit and receive ports are located at the top of the CLIP. The receive port is located on the left and has an arrow pointing towards the CLIP label. The transmit port is located on the right and has an arrow pointing away from the CLIP label.

The MCU DWDM transmit and receive ports are the two bottom ports located on the A- and B-side Line modules (LMs). The receive port is labeled "IN" and the transmit port is labeled "OUT."

Cisco recommends that you label the client-side transmit and receive fiber and A-side and B-side DWDM fibers at each end of the fiber span to avoid confusion with cables that are similar in appearance.


Warning Follow all directions and warning labels when working with optical fibers. To prevent eye damage, never look directly into a fiber or connector.

Procedure: Connect the Client Layer Fiber


Step 1   Remove the dust plugs from the CLIP module client-layer connectors.

Step 2   Clean and inspect the client-layer optical-fiber jumper cable connectors.

Step 3   Connect the CLIP module input and output to the customer-specified point.

Step 4   Repeat Steps 1 -3 for each CLIP.

Step 5   Guide the fiber through the fiber guide above the MCU and then to the cable ties mounted on the sides of the rack. The cable ties hold the fiber to the side of the rack to reduce the risk of fiber pinching.


Procedure: Connect the DWDM Fiber


Step 1   Remove the dust plugs from the A-side LM DWDM optical connectors.

Step 2   Clean and inspect the A-side DWDM optical-fiber jumper cable connector.

Step 3   Connect the A-side DWDM input and output to the customer-specified demarcation point.

Step 4   Repeat on the B-side LM.

Step 5   Guide the fiber through the cable ties mounted on the rack. The cable ties hold the fiber to the side of the rack to reduce the risk of fiber pinching.


3.5  ONS 15201 SCU Assembled-to-Order Installation

This section describes how to install an assembled-to-order (ATO) ONS 15201 SCU in an equipment rack.


Note   You can install the ground and power cables before mounting the SCU. See the "Connect the ONS 15201 SCU to Ground" procedure and the "Install the ONS 15201 SCU Power" procedure for more information.


Note   Clean all optical connectors and use covers to protect them.


Caution   Static electricity can damage electro-optical equipment. While unpacking and handling electro-optical modules, wear a grounding wrist strap to discharge the static buildup. Grounding wrist straps are designed to prevent equipment damage caused by static electricity. Before making the necessary interconnections, connect the grounding wrist strap.


Caution   Do not use the AC cord that can be ordered for the SCU in cable management devices such as wiring ducts, plenums, or risers. For such applications, you must provide an approved AC power cord. At minimum, the AC power cord must meet all National Electrical Code (NFPA 70, National Electrical Code, 2000 Edition) and all local building code requirements. This applies to Central Offices and other buildings.

The ONS 15201 SCU, shown in Figure 3-16, is designed to be installed at ONS 15200 system client sites.

Procedure: Mount the ONS 15201 SCU in an Equipment Rack


Step 1   Align four M6 cage nuts in the equipment rack with the mounting holes on the front of the SCU.

Step 2   Align the SCU with the equipment rack and cage nuts.

Step 3   Insert the SCU into the equipment rack.

Step 4   Connect the SCU to the equipment rack with four M6 screws.



Figure 3-16: An ONS 15201 SCU with front covers removed


3.5.1  Connect the ONS 15201 SCU to Ground

The lug on the ONS 15201 SCU ground cable can be either a single lug or dual lug as shown in Figure 3-11. You can also ground the ONS 15201 SCU using a ground strip as shown in Figure 3-12.

Procedure: Install an ONS 15201 SCU Single-Lug Ground Connection


Step 1   Remove one M6 nut and washer from one of the grounding pins located on the SCU backplane as shown in Figure 3-17.


Figure 3-17: ONS 15201 SCU power and ground connections


Step 2   Route the ground cable to the grounding pin where the M6 nut and washer were removed.

Step 3   Attach the ground cable to the grounding pin using the M6 nut and washer removed in Step 1.

Step 4   Firmly tighten the M6 nut on the grounding pin with a socket wrench.

Step 5   Connect the other end of the ground cable to a reliable earth ground.

Step 6   Use a multimeter that is set to read ohms to test the ground connection. The display on the multimeter should be less than 5 ohms. If the display is more than 5 ohms, tighten or reconnect the ground connection and test it again.


Procedure: Install an ONS 15201 SCU Dual-Lug Ground Connection


Step 1   Remove the M6 nut and washer from two of the grounding pins located on the back of the SCU as shown in Figure 3-17.

Step 2   Route the ground cable to the grounding pins where the M6 nuts and washers were removed.

Step 3   Attach the ground cable to the grounding pins using the M6 nuts and washers removed in Step 1.

Step 4   Firmly tighten the M6 nuts on the grounding pins with a socket wrench.

Step 5   Connect the other end of the ground cable to a reliable earth ground.

Step 6   Use a multimeter that is set to read ohms to test the ground connection. The display on the multimeter should be less than 5 ohms. If the display is more than 5 ohms, tighten or reconnect the ground connection and test it again.


Procedure: Install an ONS 15201 SCU Ground Strip Connection


Step 1   Remove one M6 nut and washer from one of the grounding pins located on the SCU backplane as shown in Figure 3-17.

Step 2   Route the ground strip to the grounding pin where the M6 nut and washer were removed.

Step 3   Attach the ground strip to the grounding pin with the M6 nut and washer removed in Step 1.

Step 4   Firmly tighten the M6 nut on the grounding pin with a socket wrench.

Step 5   Connect the other end of the ground strip to a reliable earth ground.

Step 6   Use a multimeter that is set to read ohms to test the ground connection. The display on the multimeter should be less than 5 ohms. If the display is more than 5 ohms, tighten or reconnect the ground connection and test it again.


3.5.2  Install the ONS 15201 SCU Power

The following procedures describe how to connect electrical power to an ONS 15201 SCU.

Procedure: Connect the Power Using AC-to-DC Power Supplies


Step 1   Route the SCU AC-to-DC power supply cable to the PS-1 connector on the rear of the unit. Figure 3-17 shows the location of the connector.

Step 2   Align the connector on the power cable with the PS-1 power connector on the rear of the SCU. Figure 3-18 shows the power cable connector.


Figure 3-18: ONS 15201 SCU power cable connector


Step 3   Insert the power cable connector into the PS-1 connector.

Step 4   Hand-tighten the power cable connector to firmly mate it to the PS-1 connector.

Step 5   Connect the AC line cord on the AC-to-DC power supply to the AC power grid.


Procedure: Connect a Redundant Power Source to the ONS 15201 SCU


Step 1   Route the SCU redundant AC-to-DC power supply cable to the PS-2 power connector on the front of the unit. Figure 3-16 shows the SCU PS-2 connector.

Step 2   Align the connector on the power cable with the PS-2 connector on the front of the ONS 15201 SCU. Figure 3-18 shows the power cable connector.

Step 3   Insert the power cable connector into the PS-2 power supply connector.

Step 4   Hand-tighten the power cable connector to firmly mate it to the PS-2 connector.

Step 5   Connect the AC line cord on the AC-to-DC power supply to the AC power grid.


Note   You can also use PS-2 as a single power-connection point.


Procedure: Connect the ONS 15201 SCU PS-1 and PS-2 Power Connections to the PDP


Warning Before installing power to the ONS 15201 SCU, remove the fuses from both the A and B sides of the BDB and PDP. Failure to do so can cause injury or death. Determine the actual wire gauge based on local engineering standards and practices.


Warning Do not reverse the polarity of the PDP connections to the ONS 15201 SCU power connections. Failure to heed this caution can cause equipment damage and personal injury.


Step 1   Remove the A- and B-side fuses from the BDB and the PDP.

Step 2   Connect the SCU power cable to the B side of the PDP. Be sure the poles are correct.

Step 3   Align the connector on the power cable with the PS-1 connector on the SCU backplane as shown in Figure 3-17.

Step 4   Connect the power cable to the PS-1 connector on the SCU backplane.

Step 5   Make sure the power cable connector is firmly mated to the PS-1 connector.

Step 6   Connect the SCU power cable to the A side of the PDP. Be sure the poles are correct.

Step 7   Align the connector on the power cable with the PS-2 connector on the front panel of the SCU.

Step 8   Connect the power cable to the PS-2 connector on the front panel of the SCU.

Step 9   Make sure the power cable connector is firmly mated to the PS-2 connector.

Step 10   Replace the A- and B-side BDB and PDP fuses.

Step 11   Verify that the A-side -48 VDC and B-side -48 VDC return (0 VDC) of the SCU are connected to the proper poles at the power source.

Step 12   Verify that the incoming power is within the range of -42 VDC to -56 VDC before applying power.


3.5.3  Install the ONS 15201 Fiber Cable


Caution   Always use the supplied ESD wristband when working with an ONS 15201.

ONS 15201 SCU client and DWDM interface use SC fiber connectors.

To install fiber-optic cables in the SCU, connect a fiber cable with the corresponding connector type to the transmit and receive ports on the CLIP and the DWDM side or Collector Filter module (CFM). On the CLIP, the transmit and receive client ports are located on the left side. The receive port is located on the bottom and has an arrow pointing towards the CLIP label.

The DWDM transmit and receive ports are located on the right side of the SCU. The A-side transmit port is located on the top left and the A-side receive is located on the bottom left. The B-side transmit is located on the top right and the B-side receive is located on the bottom right. The ports are labeled for the A side and the B side with arrows indicating which is transmit and which is receive. See Figure 3-16 for clarification.

Cisco recommends that you label the client side transmit and receive fibers and A-side and B-side DWDM fibers at each end of the fiber span to avoid confusion with cables that are similar in appearance.


Warning Follow all directions and warning labels when working with optical fibers. To prevent eye damage, never look directly into a fiber or connector.


Procedure: Connect the Client Layer Fiber

Use the following procedure to connect the ONS 15201 CLIP to the customer-specified point.


Step 1   Remove the dust plugs from the CLIP module client-layer connectors.

Step 2   Remove the caps from the connectors.

Step 3   Clean and inspect the client-layer optical-fiber jumper cable connectors.

Step 4   Connect the CLIP module input and output to the customer-specified demarcation point.


Procedure: Connect the DWDM Fiber

Use the following procedure to connect the ONS 15201 DWDM signal to the customer-specified demarcation point.


Step 1   Remove the dust plugs from the A-side DWDM optical connectors.

Step 2   Clean and inspect the A-side DWDM optical-fiber jumper cable connector.

Step 3   Connect the A-side DWDM input and output to the customer-specified demarcation point.

Step 4   Repeat on the B-side.

3.6  ONS 15252 MCU Module Installation (Non-ATO)

Normally, the ONS 15252 MCU is configured and shipped with customer-requested modules installed (assembled to order [ATO]). The ATO MCU contains a R1.0.1 shelf. See "Shelf Version Considerations" procedure.

Use the following module installation instructions only when an MCU must be built from scratch. Figure 3-19 shows the MCU without modules installed. If the MCU was not assembled to order, see the "ONS 15252 MCU Assembled-to-Order Installation" procedure for procedures to remove the crossbeam, install the fan unit, fiber organizer, ground, power, and fibers.


Warning Before installing the ONS 15252 MCU, remove the fuses from both the A and B sides of the PDP. Failure to do so can cause injury or death.


Warning Touching electrical connectors or other exposed electrical circuitry inside the ONS 15252 MCU when it is energized can cause serious injury or death.


Caution   Static electricity can damage electro-optical equipment. While unpacking and handling electro-optical modules, wear a grounding wrist strap to discharge the static buildup. Grounding wrist straps are designed to prevent equipment damage caused by static electricity. Before making the necessary interconnections, connect the grounding wrist strap.


Note   Clean all optical connectors and keep them protected with caps prior to connection.


Figure 3-19: An ONS 15252 MCU without modules


Procedure: Install the Network Control Board Module in the ONS 15252 MCU


Step 1   Align the NCB module with the NCB module slot located on the right of the upper portion of the ONS 15252 MCU (Slot 17).

Step 2   Carefully insert the NCB module in the NCB module slot as shown in Figure 3-20. Be sure the NCB module connector and the backplane connector mate correctly.


Figure 3-20: Installing a Network Control Board in an ONS 15252 MCU


Step 3   Tighten the NCB module thumbscrews.


Procedure: Install the Communication Interface Module in the ONS 15252 MCU


Step 1   Align the CIM with the slot directly below the NCB module.

Step 2   Carefully insert the CIM into the slot and lower guide rail, making sure that no fibers are pinched in the process. Be sure the CIM connector and the backplane connector mate correctly.

Step 3   Use a slot or Phillips screwdriver to tighten the CIM retaining screws.

Figure 3-21 shows the CIM installed in the ONS 15252 MCU.



Figure 3-21: Installing a Communications Interface module in an ONS 15252 MCU


Procedure: Install the Client Layer Interface Port Module in the ONS 15252 MCU


Step 1   Align the CLIP module with a CLIP module slot in the MCU. Install CLIP modules from left to right.

Step 2   Carefully insert the CLIP module into the slot. Be sure the CLIP module connector and the backplane connector mate correctly.

Step 3   Tighten the CLIP module thumbscrews.

Step 4   Repeat Steps 1-3 for each CLIP module in the ONS 15252 MCU.

Step 5   Install a CLIP module slot cover for each empty CLIP module slot.

Figure 3-22 illustrates an ONS 15252 MCU with three CLIP modules installed.



Figure 3-22: Installing a Client Layer Interface Port module in an ONS 15252 MCU


Procedure: Install the Line Module in the ONS 15252 MCU


Step 1   To open the MCU passive optical shelf, pull up on the door latches located on the left and right sides of the door and pull gently towards you. Figure 3-23 illustrates an ONS 15252 MCU with the passive optical shelf door open.


Figure 3-23: An ONS 15252 MCU with the passive optical shelf door open


Step 2   Align the A-side LM with the far left position (if applicable) and the B-side LM with the far right position (if applicable) in the passive optical shelf. Insert them as shown in Figure 3-24.

Step 3   Make sure the crossbar at the back of the passive optical shelf and the groove in the back of the LMs fit together.

Step 4   Push the button at the bottom front of the LMs and snap the LMs into place.



Figure 3-24: Installing a Line module in an ONS 15252 MCU


Procedure: Position the Hub Filter Modules in the ONS MCU 15252 Passive Optical Shelf

This procedure explains how to insert the Hub Filter modules (HFMs). However, before actually connecting the HFMs as described in the "Interconnect the ONS 15252 MCU Passive Optical Shelf Modules" procedure, you must install the following modules:


Step 1   Align an HFM with the designated location in the ONS 15252 MCU passive optical shelf. Installation of the A-side HFM modules should be from left to right, starting with the slot adjacent to the A-side LM. Installation of the B-side HFM modules should be from right to left, starting with the slot adjacent to the B-side LM.

Step 2   Insert and slide the HFM into the passive optical shelf.

Be sure that the crossbeam in the passive optical shelf interlocks with the slot on the bottom of the HFM.

Step 3   Once the HFM is positioned in place in the passive optical shelf, push the retainer button located at bottom of the HFM front panel and snap the HFM into place.

Step 4   Repeat Steps 1-3 for each HFM located in the MCU passive optical shelf. Once the HFMs are installed in the passive optical shelf, the MCU should appear as illustrated in Figure 3-25.



Figure 3-25: Installing a Hub Filter module in an ONS 15252 MCU


Procedure: Install the Bridge Module in the ONS 15252 MCU Passive Optical Shelf

You will install one BM, or one or two TMs, but not both a BM and a TM together. See the "Install the Termination Module in the ONS 15252 MCU Passive Optical Shelf" procedure. You can also install a combination of Connection Module Xs (CMXs) and Connection Module Ys (CMYs). See the "Install a Connection Module X in Two ONS 15252 MCUs" procedure and the "Install a Connection Module Y in Two ONS 15252 MCUs" procedure. Figure 3-26 illustrates a BM installation.


Step 1   Position the BM into the passive optical shelf at the end of the A-side and B-side rows of HFMs. Place one side of the BM at the end of the A-side row of HFMs and the other side of the BM at the end of the B-side row of HFMs.

Step 2   Carefully slide each side of the BM into the passive optical shelf. Be sure the passive optical shelf crossbeam and the slot on the bottom of each side of the BM connect properly.

Step 3   Push the retainer button located on the bottom of each side of the BM front panel and individually snap each side of the BM into place.



Figure 3-26:
Installing a Bridge module in an ONS 15252 MCU


Procedure: Install the Termination Module in the ONS 15252 MCU Passive Optical Shelf

You will install a BM, or one or two TMs, but not both a BM and a TM together. See the "Install the Bridge Module in the ONS 15252 MCU Passive Optical Shelf" procedure. You can also install a combination of Connection Module Xs (CMXs) and Connection Module Ys (CMYs). See the "Install a Connection Module X in Two ONS 15252 MCUs" procedure and the "Install a Connection Module Y in Two ONS 15252 MCUs" procedure.


Step 1   Position the TM in the passive optical shelf at the end of the row of HFMs.

Step 2   Carefully slide the TM into the passive optical shelf. Be sure the groove on the back of the TM connects with the passive optical shelf crossbeam.

Step 3   Push down on the TM retainer button located on the TM front panel and snap the TM into place.

Step 4   If applicable, repeat Steps 1-3 for the other TM.


Procedure: Install a Connection Module X in Two ONS 15252 MCUs


Note   Use this procedure if you are using two or more installed assembled-to-order (ATO) MCUs.


Step 1   Disconnect the MU duplex connector from the TM you will replace.

Step 2   Put protective caps on the MU duplex connector.

Step 3   Remove a TM module from the passive optical shelf of the first MCU.

Step 4   Position one side of the CMX (Figure 3-27) in the passive optical shelf of the first MCU where the TM was removed.


Figure 3-27: Side view of a CMX module


Step 5   Carefully insert the half CMX into the passive optical shelf. Be sure the groove on the back of the module interlocks with the crossbeam located in the passive optical shelf.

Step 6   Snap the CMX into place by pushing the retainer located at the bottom of the CMX.

Step 7   Remove the dust plugs located on the CMX duplex MU-MU adapter.

Step 8   Remove the fiber caps on the MU duplex connector in the adjacent HFM.

Step 9   Clean, inspect, and insert the MU duplex connector from the adjacent HFM into the CMX.

Step 10   Fasten a fiber holder on the side of the passive optical shelf just outside the door.

Step 11   Guide the optical fiber cable from the CMX to the fiber holder and fasten the cable.

Step 12   Remove the fiber caps on the MU duplex connector in the adjacent HFM.

Step 13   Remove the MU plugs in the CMX half.

Step 14   Inspect and clean the duplex MU connector.

Step 15   Insert the connector in the CMX half.

Step 16   Remove a TM from the passive optical shelf of the second MCU.

Step 17   Place dust caps on the connectors.

Step 18   Position the second half of the CMX in the passive optical shelf of the second MCU where the TM was removed.

Step 19   Carefully insert half of the CMX into the passive optical shelf. Be sure the groove on the back of the module interlocks with the crossbeam in the passive optical shelf.

Step 20   Snap the CMX into place by pushing downwards on the CMX front panel.

Step 21   Remove the dust caps from the duplex connector of the adjacent HFM.

Step 22   Remove the dust plugs located on the CMX duplex adapter.

Step 23   Clean, inspect, and insert the MU duplex connector from the adjacent HFM into the CMX.

Step 24   Fasten a fiber holder on the side of the passive optical shelf just outside the door.

Step 25   Guide the optical fiber cable from the CMX to the fiber holder and fasten the cable.


Procedure: Install a Connection Module Y in Two ONS 15252 MCUs


Note   Use this procedure if you are using two installed assembled-to-order (ATO) MCUs.


Step 1   Disconnect the adjacent HFM from the TM that you will remove.

Step 2   Protect the optical duplex MU connector with fiber caps.

Step 3   Remove a TM from the passive optical shelf of the first ONS 15252 MCU.

Step 4   Position the CMY (Figure 3-28) in the passive optical shelf of the first MCU where you removed the TM.


Figure 3-28: Side view of a CMY module


Step 5   Carefully insert the CMY. Be sure the groove on the back of the module interlocks with the crossbeam in the passive optical shelf.

Step 6   Snap the CMY into place by pushing the retainer located at the bottom of the CMY front panel.

Step 7   Remove the dust plugs located on the CMY duplex adapter.

Step 8   Remove the fiber caps on the adjacent HFM.

Step 9   Clean, inspect, and insert the MU duplex connector from the adjacent HFM into the CMY.

Step 10   Fasten a fiber holder on the side of the passive optical shelf just outside the door.

Step 11   Guide the optical fiber cable from the CMY to the fiber holder and fasten the cable.

Step 12   Remove the dust plugs from the appropriate HFM in the second MCU.

Step 13   Remove the dust caps located on CMY optical fiber connectors.

Step 14   Clean, inspect, and insert the MU duplex connector from the CMY into the HFM in Step 12.

Step 15   Fasten a fiber holder on the side of the passive optical shelf just outside the door of the second MCU.

Step 16   Guide the optical fiber cable from the CMY to the fiber holder and fasten the cable.


Procedure: Install the Dummy Filter Module in the ONS 15252 MCU


Step 1   Position the DFM in the passive optical shelf between the last A-side optical module and the last B-side optical module.

Step 2   Slide the DFM into the passive optical shelf. Be sure the slot located on the back of the DFM aligns with the crossbeam in the rear of the ONS 15252 MCU.

Step 3   Snap the DFM into place by pressing the retainer button located at the bottom front of the DFM.

Step 4   Repeat Step 1 - 3 until the passive optical shelf is filled (Figure 3-29).



Figure 3-29: Installing a Dummy Filter module in an ONS 15252 MCU


Procedure: Interconnect the ONS 15252 MCU Passive Optical Shelf Modules

After positioning the HFMs, and installing the BMs or TMs, CMX or CMY, and DFMs, connect the passive optical shelf modules to complete the passive optical shelf installation.


Step 1   When all HFMs, the BM/TM, the CMX/CMY, and the DFMs are installed in the passive optical shelf, remove the dust plugs from the duplex MU adapter on the HFM closest to the LM (from left to right on the A side and from right to left on the B side).

Step 2   Remove the dust caps from the MU duplex connector connected to the LM.

Step 3   Clean and inspect the LM MU duplex fiber cable connector.

Step 4   Connect the LM MU duplex fiber jumper connector to the duplex MU adapter of the HFM closest to the LM.

Step 5   Remove the dust plugs from the optical-fiber jumper cable connector in the HFM.

Step 6   Remove the dust plugs from the duplex MU optical adapter in the next HFM.

Step 7   Clean and inspect the optical-fiber jumper cable connector in the first HFM.

Step 8   Connect the duplex MU optical-fiber jumper cable connector to the next module.

Step 9   Repeat Steps 3-8 until all modules have been interconnected, ending with either a BM half, a TM, a CMX half, or a CMY.

Step 10   Repeat the procedure for both the A and B sides, if applicable, and with other MCUs, if applicable (using CMX and/or CMY).

When the modules are connected, see Figure 3-30 for an example of what the passive optical shelf should look like (with a BM module installed).



Figure 3-30: The ONS 15252 MCU passive optical shelf after the modules are connected


Procedure: Install the Network Adaptation Module in the ONS 15252 MCU

Cisco builds NAM modules per customer design specifications. If you plan to install multiple NAMs, verify that the NAM splitter ratio (50/50, 90/10, 10/90, 100/0, or 0/100) matches the requirements of the associated CLIP module.


Caution   In an ONS 15200 Release 1.0.1 shelf assembly, you must install the Release 1.0.1 NAM, identified by the "NEBS-3 compliant" faceplate. Cisco does not recommend or support placing NAMs without the "NEBS-3 compliant" faceplate into an Release 1.0.1 shelf. Equipment damage may result. For more information about shelf versions, see "Shelf Version Considerations" procedure.


Note   You can install Release 1.0.1 NAMs (identified by the "NEBS-3 compliant" faceplate label) in either a Release 1.0 or Release 1.0.1 shelf. See "Shelf Version Considerations" procedure.


Step 1   Align the NAM with the NAM slot immediately below a previously installed CLIP module.

Step 2   Carefully insert the NAM into the slot. Make sure that the NAM is properly inserted in the lower guide rail located in the NAM slot, and that the NAM connector and the backplane connector mate correctly.


Caution   When you insert the NAM, ensure that the fiber cables and connector emerging from the NAM are not pinched, which could damage the fibers.

Step 3   Use a slot or Phillips screwdriver to tighten the NAM retaining screw.

Step 4   Remove the dust plugs from the CLIP module.

Step 5   Remove the dust cap from one of the three NAM MU connectors (for a protected channel) or one of the two NAM MU connectors (for an unprotected channel), as shown in Figure 3-31. Start with the fibers connected to the receivers, labeled either A or B.

Step 6   Clean and inspect the MU connector.

Step 7   For a protected channel, connect the NAM fiber labeled A and B to the corresponding MU optical adapters (also labeled A and B) on the associated CLIP module.

Step 8   Repeat Steps 6 and 7 for the other receiver.

Step 9   For an unprotected channel, connect the optical-fiber jumper cable labeled A to the A-side MU adapter on the associated CLIP module.

Step 10   Connect the transmitter optical fiber to the DWDM transmitter MU adapter on the CLIP (labeled with a down arrow). See Figure 3-32.


Note   The receive side of the duplex fiber connected to the HFM is labeled with the intended side of the passive optical shelf. The transmit side of the fiber is labeled with the transmitted power percentage.


Figure 3-31: Installing an ONS 15252 MCU Network Adaptation module (Part 1)


Step 11   One at a time, remove the dust caps on the connectors coming from the NAM.

Step 12   Remove the dust plugs on the associated HFM optical connectors.

Step 13   Clean and inspect the optical-fiber jumper cable connectors. Connect the duplex MU optical connectors from the NAM to the associated HFM.

Step 14   Repeat Steps 11-13 for protected traffic. Use the labeling on the fiber to ensure that the A side and the B side of the node are not interchanged (Figure 3-32).


Figure 3-32: Installing an ONS 15252 MCU Network Adaptation module (Part 2)


Step 15   After connecting the NAM fiber to the HFM, push the HFM slightly upward to expose the two lateral grooves on the top of the HFM.

Step 16   Insert the fiber into the lateral grooves and snap the HFM back into place (Figure 3-33).


Figure 3-33: Installing an ONS 15252 MCU Network Adaptation module (Part 3)


Step 17   For protected channels, repeat Step 15 and Step 16 for the other HFM.

Step 18   Store excess length of the fiber in the space between the NAM and the MCU passive optical shelf (shown in Figure 3-33).

Step 19   Repeat Steps 1-16 for each NAM in the MCU.


Procedure: Install the Dummy Network Adaptation Module in the ONS 15252 MCU

You must install a Dummy Network Adaptation module (DNAM) in all unused NAM slots.


Step 1   Align a DNAM with an empty NAM slot.

Step 2   Carefully insert the DNAM into the slot. Be sure the DNAM connector and the backplane connector mate correctly, and that no fibers are pinched in the process.


Caution   When you insert the DNAM, ensure that the fiber and connector emerging from the adjacent NAMs are not pinched, which could damage the fibers.

Step 3   Use a slot or Phillips screwdriver to tighten the DNAM retaining screws.

Step 4   Repeat Steps 1-3 for each DNAM you are installing in the MCU.

The ONS 15252 MCU with all modules installed and cover lid shut is shown in Figure 3-34.



Figure 3-34: An installed ONS 15252 MCU Dummy Network Adaptation module


3.7  ONS 15201 SCU Module Installation (Non-ATO)

Normally, the ONS 15201 SCU is configured and shipped with the customer-requested modules already installed. Use the following module installation instructions only when you must build the ONS 15201 SCU from scratch. The following paragraphs describe how to install the individual modules in the ONS 15201 SCU.

Before beginning this section, see the "ONS 15201 SCU Assembled-to-Order Installation" procedure to mount the equipment in a rack, and install power, ground, and fiber.

Procedure: Install the Collector Filter Module


Step 1   Remove the front covers of the ONS 15201 SCU.

Step 2   Locate the CFM cover lid (Figure 3-35).


Figure 3-35: The cover lid of the ONS 15201 SCU Collector Filter module


Step 3   Use a slot or Phillips screwdriver to loosen the retaining screws on the CFM cover lid. The positions of the retaining screws are shown in Figure 3-36.


Figure 3-36: Position of retaining screws on the Collector Filter module cover lid


Step 4   Remove the cover lid by sliding it to the right and pulling up.

Step 5   Use a slot or Phillips screwdriver to loosen the rear collector cover retaining screws of the rear connector cover. Figure 3-37 shows the position of the retaining screws.


Figure 3-37: ONS 15201 SCU rear connector cover and retaining screws


Step 6   Remove the rear connector cover by sliding it back and pulling up.

Step 7   Carefully insert the CFM into the SCU. Be careful not to damage the CFM fiber while inserting the module.

Step 8   Align the four holes in CFM case with the four CFM standoffs inside the SCU. When properly aligned, the CFM standoffs fit in the holes in the CFM case.

Step 9   Fasten the CFM to the CFM standoffs with four retaining screws.

Step 10   Remove the dust plugs located on the inside of the SCU SC-to-SC adapters.

Step 11   Perform the following for each SC connector on the CFM fiber:

Step 12   Connect the CFM fiber to the A- and B-side SC-to-SC adapters in accordance with the labels on the cables. Figure 3-38 shows a CFM for an unprotected channel; Figure 3-39 shows a CFM for a protected channel. Figure 3-40 through Figure 3-44 show the connection information for each configuration.


Figure 3-38: CFM for an unprotected channel (100/0 or 0/100)



Figure 3-39:
CFM for a protected channel (90/10, 10/90, or 50/50)



Figure 3-40:
90/10 split ratio (protected) connections



Figure 3-41:
10/90 split ratio (protected) connections



Figure 3-42:
50/50 split ratio (protected) connections for a CFM



Figure 3-43:
0/100 split ratio (unprotected) connections for a CFM



Figure 3-44:
100/0 split ratio (unprotected) connections for a CFM


Step 13   Route the CFM MU connectors to the CLIP module area (a CLIP has not yet been installed) through the opening in the front panel of the SCU (to the left of the LED-panel).

Step 14   Align the rear collector cover with its retaining screws.

Step 15   Install the rear collector cover.

Step 16   Use a slot or Phillips screwdriver to tighten the rear collector cover retaining screws.

Step 17   Align the CFM access lid with the rear collector cover retaining screws.

Step 18   Install the CFM access lid by pushing down on the lid and sliding it to the left.

Step 19   Use a slot or posidrive screwdriver to tighten the CFM access lid retaining screws.


Procedure: Install the Client Layer Interface Port Module


Step 1   Align the CLIP module with the CLIP module slot in the ONS 15201 SCU.

Step 2   Carefully insert the CLIP module in the slot. Be sure the CLIP module connector and the backplane connector mate correctly and that no fibers are pinched.

Step 3   Tighten the CLIP module thumbscrews.

Step 4   Remove the MU dust cap from one of the MU connectors on the CFM.

Step 5   One at a time, remove the dust plugs from the CLIP module optical-fiber adapter, starting with the receivers.

Step 6   Clean and inspect the connectors on the fiber.

Step 7   Connect the fiber to the CLIP module optical connectors in accordance with the labels located on the cables, starting with the receivers.

Step 8   Repeat Steps 1 - 7 for each SCU in the configuration.


3.8  ONS 15200 System Internal Bus Connection

You can extend the ONS 15200 system internal bus between system nodes by physically connecting control area network (CAN) bus cables between the nodes.

You may combine the two different network objects as long as the total CAN bus length is less than 22 meters and the following rules apply:


Note   You can obtain one-meter (3.3 ft.) and five-meter (16.4 ft.) bus cables from Cisco (P/N 72-2654 and 72-2790, respectively).

Route the bus cables from one node to another and connect them to the INT BUS ports.

A CAN bus connects CLIP modules on an ONS 15252 MCU, as well as the NCB modules (no more than two NCB modules are allowed per CAN bus). You can extend this data bus over several co-located network elements (ONS 15252 MCUs or ONS 15201 SCUs) to a larger logical unit. Normally one CAN bus connects all ONS 15200 equipment located at one site.


Figure 3-45: MCU CAN-bus access points



Figure 3-46:
SCU CAN-bus access points


When several MCUs are joined on a single CAN bus, they must have different backplane jumpers. The backplane jumpers are located between Slots 15 and 16 of the MCU backplane (Figure 3-47).

When leaving the factory, the two jumpers are set to 00. When adding MCUs to a single CAN bus, reset these jumpers to 01, 10, and 11. In an MCU with backplane jumpers set to 11, only Slots 1 through 12 will be used because the system will try to assign identical DCN addresses to all CLIPs in Slots 12 through 16. Each CLIP must have a unique DCN address.


Note   Before changing the MCU backplane jumper settings, turn the MCU power off. After you have changed the settings, turn the power back on. When the you restart the power, the system assigns each CLIP a new unique DCN address. If you can't change the MCU backplane jumper settings due to live traffic, the firmware will resolve address conflicts as they occur.


Figure 3-47: Jumpers on the MCU backplane


3.9  Additional Channel Installation

This section describes how to install an additional channel in an ONS 15200 system. To add a channel, two CLIP modules are necessary at different nodes, either an MCU or an SCU.


Caution   Installing a new channel may cause traffic interruption for some configurations. Before adding a channel, verify that protected CLIPs are not set to switch mode "forced_a" or "forced_b."

3.9.1  Channel Installation in an ONS 15252 MCU

This section describes how to set up an additional channel at an ONS 15252 MCU. Because a channel is always between different nodes, repeat the process at the other endpoint of the channel. If you instead plan to add a channel between an MCU and SCU, after completing the procedures in this section, continue with the "Channel Addition Using an ONS 15201 SCU" procedure.

Procedure: Install a Client Layer Interface Port Module at the ONS 15252 MCU


Step 1   Open the ONS 15252 MCU passive optical shelf door.

Step 2   Remove the common cover for the CLIPs.

Step 3   Remove the blank front panel from the first slot on the right side of the installed CLIP modules.

Step 4   Align the CLIP module with the CLIP module slot.

Step 5   Carefully insert the CLIP module into the slot. Be sure that the backplane connector and the CLIP module connector are correctly mated and that no optical fiber is damaged in the process.

Step 6   Tighten the CLIP module thumbscrews.


Procedure: Install an A-Side Hub Filter Module

For each fiber-protected channel to be installed in the ONS 15252 MCU, you must install two Hub Filter modules (HFMs) in the passive optical shelf—one for the A side and one for the B side. Your network planner will help you determine where the HFMs should be installed for optimal performance.


Note   If you are installing an HFM for an unprotected channel, you do not need to install an HFM on both the A and B sides.


Step 1   Unplug the connector that connects the two modules where the new HFM is to be inserted.

Step 2   Place dust caps on the appropriate fiber connectors.

Step 3   Slide the existing HFMs and DFMs to the right to make room for the new HFM. If necessary, remove a few DFMs and replace them after completing the procedure.

Step 4   Insert the new HFM between the two modules mentioned in Step 1 .

Step 5   Disconnect the duplex fiber connector from the duplex MU adapter of the new HFM.

Step 6   Clean and inspect the fiber connectors of the new HFM.

Step 7   Connect the new HFM to the adjacent HFM.

Step 8   Remove the dust caps from the fiber connectors of the HFM (installed in Step 1 ).

Step 9   Attach the duplex MU connectors to the new HFM.


Procedure: Install a B-Side Hub Filter Module


Step 1   Unplug the connector that connects the two modules where the new HFM is to be inserted.

Step 2   Place dust caps on the appropriate fiber connectors.

Step 3   Slide the existing HFMs and DFMs to the left to make room for the new HFM. If necessary, remove a few DFMs and replace them after completing the procedure.

Step 4   Insert the new HFM between the two modules mentioned in Step 1 .

Step 5   Disconnect the duplex fiber connector from the duplex MU adapter of the new HFM.

Step 6   Clean and inspect the fiber connectors of the new HFM.

Step 7   Connect the new HFM to the adjacent HFM.

Step 8   Remove the dust caps from the fiber connectors of the second HFM (installed in Step 1 ).

Step 9   Attach the duplex MU connectors to the new HFM.


Procedure: Install a Network Adaptation Module


Step 1   Remove the DNAM from the slot directly below the CLIP module installed in the "Install a Client Layer Interface Port Module at the ONS 15252 MCU" procedure.

Step 2   Slide the new NAM into the slot where the DNAM was removed.

Step 3   Use a slot or Phillips screwdriver to tighten the retaining screws.


Note   Ensure that the NAM fibers are not pinched when you insert the module.


Procedure: Connect the Network Adaptation Module to the A-side Hub Filter Module


Step 1   Remove the dust plugs from the A-side HFM installed in the "Install an A-Side Hub Filter Module" procedure.

Step 2   Clean the NAM connector labeled A-XX. The letter A on the receiver fiber indicates the A side of the MCU, and the XX on the transmit fiber indicates the split factor of the NAM.

Step 3   Connect the fiber from the NAM to the HFM.

Step 4   Insert the fibers from the NAM into the grooves along the top of the HFM. You must move the HFM upward slightly to access the grooves at the top. Arrange the fibers from the NAM in a smooth curve on top of the passive optical shelf. Keep the permanent fiber bending radius above 35 mm.

Step 5   Carefully snap the HFM back into place after you insert the fibers.


Procedure: Connect the Network Adaptation Module to the B-side Hub Filter Module


Step 1   Remove the dust plugs from the B-side HFM installed in the "Install a B-Side Hub Filter Module" procedure.

Step 2   Clean the NAM connector labeled B-XX. The letter B indicates the B side of the MCU, and the XX indicates the split factor of the NAM.

Step 3   Connect the fiber from the NAM to the HFM.

Step 4   Insert the fibers from the NAM into the grooves along the top of the HFM. Move the HFM upward slightly to access the grooves at the top. Arrange the fibers from the NAM in a smooth curve on top of the passive optical shelf.

Step 5   Snap the HFM back into place after you insert the fibers.


Procedure: Connect the Network Adaptation Module to the Client Layer Interface Port Module


Step 1   Remove the dust plugs from the fiber adapters on the bottom of the CLIP module.

Step 2   Clean and inspect the fiber from the NAM that is labeled A.

Step 3   Connect the fiber labeled A to the A-side DWDM receiver on the CLIP module.

Step 4   If the channel is protected, clean the fiber from the NAM that is labeled B.

Step 5   Connect the fiber that is labeled B to the B-side DWDM receiver on the CLIP module.

Step 6   Clean the transmit DWDM fiber.

Step 7   Connect the DWDM fiber from the NAM to the center fiber input on the CLIP module (labeled with a down arrow).


Procedure: Add a Channel at Another ONS 15252 MCU


Step 1   Complete the procedures described in the "Channel Installation in an ONS 15252 MCU" procedure for a second ONS 15252 MCU.

Step 2   Check the optical power levels.

Step 3   At each MCU, connect the client-layer fibers:

3.9.2  Channel Addition Using an ONS 15201 SCU

This section describes how to complete a channel by adding an ONS 15201 SCU to the ring.

Procedure: Add an ONS 15201 SCU to the Ring


Step 1   Set the switchmode for all CLIP modules in the ring to automatic:

Step 2   Install the new SCU (ATO) in the equipment rack.

Step 3   Inhibit the board.power alarm if you are only using one power source.

Step 4   Connect the new SCU power to power connector PS1 or PS2 (or both if redundant power supplies are used) and verify that no red LED is lit.

Step 5   To break the ring, disconnect the fiber connecting the ONS 15252 MCU to the ONS 15201 SCU A-side IN and OUT ports, or the fiber between two SCUs.

Step 6   To connect the new SCU:

Step 7   Connect the client ports of the new SCU to the appropriate client equipment.