Acceptance Test Plan

Acceptance Test Plan

This chapter contains tables and checklists sheets to use during the first turn up and test of a Cisco ONS 15200 system. When you are performing the turn up and test procedures in "Turn Up and Test," you are asked to complete the tables in this appendix to prepare for customer acceptance of the ONS 15200 system.


Table B-1: Customer Information

Customer

Site Name

Location

System Configuration


Table B-2: Team Information

Lead Engineer

Test Engineer

Test Engineer

Date

B.1  ONS 15200 Network Configuration


Table B-3: ONS 15200 Network Configuration Checklist
Related Step in Chapter 4 Description Pass Fail

13

All Client Layer Interface Port modules display correctly

B.2  ONS 15252 Multichannel Unit Turn Up and Test


Table B-4: ONS 15252 MCU Turn Up and Test Procedure Checklist
Related Step in Chapter 4 Description Pass Fail

2

Data is consistent with network planner

3

A-side Hub Filter Module (HFM) order correct

3

B-side HFM order correct

10

Alarm verification

12

A-side to B-side switch

13

A-side standby, B-side active

14

B-side to A-side switch

15

A-side active, B-side standby

17

BER test error free for 15 minutes—unprotected

18

BER test error-free for 15 minutes—A-side

19

BER test error-free for 15 minutes—B-side


Table B-5: ONS 15252 MCU CLIP Data
Slot Number CLIP Serial Number ITU Channel Number ITU Frequency (THz) Wavelength (nm) Tx Power (dB) MU Transmit Attenuator (8 or 0 dB) Splitter Ratio

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16


Note   The expected minimum and maximum transmit power is provided by your network planner. Actual transmit power must be within the range provided by your network planner.
Table B-6: A-Side ONS 15252 MCU Wavelength and Output Power Data
A-Side Slot Number Wavelength Expected (nm) Wavelength Reading from Frequency Meter (nm) Output Power Expected (dBm) Output Power Measured (dBm) Output Power Measured Within Network Planner Range
Pass or Fail

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16


Table B-7: B-Side ONS 15252 MCU Wavelength and Output Power Data
B-Side Slot Number Wavelength Expected (nm) Wavelength Reading from Frequency Meter (nm) Output Power Expected (dBm) Output Power Measured (dBm) Output Power Measured Within Network Planner Range
Pass or Fail

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16


Table B-8: ONS 15252 MCU DWDM Receive Data
Slot Number Attenuated OSA Reading A Side DWDM
A-Side
Rx
Expected
(dBm)
DWDM
A-Side
Rx
Measured
(dBm)
Pass or Fail Attenuated OSA Reading B-Side DWDM
B-Side
Rx
Expected
(dBm)
DWDM
B-Side
Rx
Measured
(dBm)

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16


Table B-9: ONS 15252 MCU Client Transmit Data
Slot Number Measured Client Transmit Power (dBm) Pass or Fail Valid Range -8 to -10 dBm

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

_(_IREFOBJ:53095_ )_
Table B-10: ONS 15252 MCU CLIP Switchmode
CLIP Serial Number Switchmode


B.3  ONS 15201 Single-Channel Unit Turn Up and Test


Table B-11: ONS 15201 Turn Up and Test Procedure Checklist
Related Step in Chapter 4 Description Pass Fail

4

Data is consistent with your network planner

10

Alarm verification

12

B side to A side switch

13

A side active, B side standby

14

A side to B side switch

15

A side standby, B side active

16

BER test error-free for 15 minutes — A-side

17

BER test error-free for 15 minutes — B-side (unprotected)

20

BER test error free for 15 minutes — unprotected

21

BER test error-free for 15 minutes — A-side

22

BER test error-free for 15 minutes — B-side


Table B-12: ONS 15201 SCU CLIP Data
CLIP Serial Number ITU Channel Number ITU Frequency (THz) Wavelength (nm) Tx Power (dBm) MU
Attenuation

Splitter
Ratio


Table B-13: ONS 15201 SCU Wavelength and Output Power Data
Output
Port
Wavelength
Expected
(nm)
Wavelength Reading from Frequency Meter (nm) Output
Power
Expected
(dBm)
Output
Power
Measured
(dBm)
Output Power Measured Within Range
Pass or Fail

A

B


Table B-14: ONS 15201 SCU DWDM Receive Data
Attenuated OSA Reading A Side DWDM
A-Side
Rx
Expected
(dBm)
DWDM
A-Side
Rx
Measured
(dBm)
Pass or Fail Attenuated OSA Reading B Side DWDM
B-Side
Rx
Expected
(dBm)
DWDM
B-Side
Rx Measured
(dBm)
Pass or Fail


Table B-15: ONS 15201 SCU Client Transmit Data
CLIP Serial Number Measured Client Transmit Power (dBm) Pass or Fail Valid Range -8 to -10 dBm


Table B-16: ONS 15201 CLIP Switchmode
CLIP Serial Number Switchmode

B.4  ONS 15200 System Span Test


Table B-17: ONS 15200 System Span Test Procedure Checklist
Related Step in Chapter 4 Description Pass Fail

12

BER test error-free for 2 hours — unprotected

13

BER test error-free for 2 hours — A-side

14

BER test error-free for 2 hours — B-side


Note   The comparison between measured and expected values is only relevant when the fiber has been characterized.
Table B-18: ONS 15200 Hub Span DWDM Transmit and Receive Measurements
ONS 15252 MCU Slot # ITU Channel OSA Measured DWDM A Side Tx OSA Measured DWDM A Side Rx OSA Measured DWDM B Side Tx OSA Measured DWDM B Side Rx


Table B-19: ONS 15200 Remote Span DWDM Transmit and Receive Measurements
Location ITU Channel OSA Measured DWDM A Side Tx OSA Measured DWDM A Side Rx OSA Measured DWDM B Side Tx OSA Measured DWDM B Side Rx


Table B-20: ONS 15252 MCU DWDM Receive Measurements
ONS 15252
MCU
Slot
Number
DWDM
A-Side
Rx
Measured
(dBm)
DWDM
A-Side
Rx
Expected
(dBm)
Rx
Measured
Within Range
Pass or Fail
DWDM
B-Side
Rx
Measured
(dBm)
DWDM
B-Side
Rx
Expected
(dBm)
Rx Measured
Within Range
Pass or Fail

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16



Note   The comparison between measured and expected values is only relevant when the fiber has been characterized. The expected received power (both a maximum and minimum value) is provided by your network planner. The value is based on customer-provided data for fiber loss.

Actual received power must fall within the range provided by your network planner.
Table B-21: ONS 15200 DWDM Receive Measurements
NE Location Remote
ITU
Number
DWDM
A-Side
Rx
Measured
(dBm)
DWDM
A-Side
Rx
Expected
(dBm)
Rx
Measured
Within Range
Pass or Fail
DWDM
B-Side
Rx
Measured
(dBm)
DWDM
B-Side
Rx
Expected
(dBm)
Rx Measured
Within Range
Pass or Fail


Table B-22: ONS 15200 CLIP Switchmode
CLIP Serial Number Switchmode



hometocprevnextglossaryfeedbacksearchhelp