This appendix provides the specifications for the Cisco Metro 1500 series system. This appendix includes the following sections:
The Cisco Metro 1500 series system is configured with one primary chassis and up to three extension chassis. (See Table A-1.)
Note Table A-1 lists the typical configuration for four chassis. The Cisco Metro 1500 Series can contain up to eight chassis. |
.
Configuration Features | Primary Chassis | Extension Chassis | ||
---|---|---|---|---|
A | B | C | ||
Standard | ||||
Chassis | X | X | X | X |
Up to 8 WCMs | X | X | X | X |
Up to 4 TDM4Es | X | X | X | X |
MUX for channels 1 to 8 | X |
|
|
|
MUX for channels 9 to 16 |
| X |
|
|
MUX for channels 17 to 24 |
|
| X |
|
MUX for channels 25 to 32 |
|
|
| X |
DMX for channels 1 to 8 of 32 | X |
|
|
|
DMX for channels 9 to 16 |
| X |
|
|
DMX for channels 17 to 24 |
|
| X |
|
DMX for channels 25 to 32 |
|
|
| X |
BSM |
| X |
|
|
DEMI |
| X |
| X |
NEMI | X |
| X |
|
Optional
| ||||
RSM | X |
|
|
|
The primary chassis and the extension chassis are built on the same chassis. Table A-2 lists the chassis specifications for the Cisco Metro 1500 series system.
Description | Specification |
---|---|
Environmental |
|
Temperature, ambient operating1 | 41 to 113°F (5 to 45°C) (long-term conditions) 23 to 122°F (-5 to 50°C) (short-term conditions) |
Temperature, ambient nonoperating and storage | 14 to 158°F (-10 to 70°C) |
Transportation temperature | 14 to 158°F (-10 to 70°C) |
Humidity (RH2), ambient (noncondensing) operating | 10 to 90 percent RH noncondensing |
Physical Characteristics |
|
Dimensions (HxWxD) | 19 x 12 x 8 3/4 in (482 x 305 x 222 mm) |
Weight | 33 lb (15 kg) maximum per base unit |
Optical ports | MiniSC (MU type) |
Power |
|
AC-input voltage DC-input voltage | 110 to 120 VAC 210 to 240 VAC |
Typical voltage range | 99 to 127.2 VAC 189 to 254.4 VAC -40 to -80 VDC |
Current maximum | 2.5A maximum |
Power consumption maximum | 150 VAC maximum |
Reliability |
|
MTBF3 at 77°F (25°C) | 442,488 hr |
FITs4 at 77°F (25°C) | 2260 |
MTTR5 | 0.34 hr |
Fuses, Fans and Power Supplies |
|
Fuses | 2.5A, 250V, slow blowing, 5x20 mm (for AC version) or 6.3A, 250V, slow blowing, 5x20 mm (for DC version) |
Fans | Two redundant fans |
Power supplies | Two redundant power supplies |
The Cisco Metro 1500 series system supports nine different wavelength channel module (WCM) configurations. These WCMs support only extended reach lasers. Table A-3 through Table A-10 list specifications for the following WCM configurations:
Note All power measurements have to be done in-line because of automatic laser shutdown (ALS). |
Description | Specification |
---|---|
Data Rate | |
Range | 10 to 200 Mbps |
Local Link Ports 1 | |
Transmitter wavelength | 1260 to 1310 nm |
Receiver wavelength | 1260 to 1570 nm |
Receiver dynamic range | -5.0 to -28.0 dBm |
Transmitter output power | -16.0 to -21.0 dBm |
Fiber type | Single mode or multimode |
Link distance | Single mode: 0.62 mi (1 km) Multimode: 0.12 mi (0.2 km) |
Connector type | MiniSC |
Remote Link Ports 1 | |
Wavelength | 1 to 32 channels, ranging from 1531.90 to 1558.98 nm, according to ITU-T2 G.692 200 GHz channel spacing |
Receiver dynamic range | -5.0 to -28 dBm |
Transmitter Output Power (measured at WCM output) | |
Extended | 6.0 to 3.0 dBm |
Link Loss Budget3 | |
Extended without RSM | 7 to 22 dB |
Extended with RSM | Up to 15 dB |
Calculated Link Distance | |
Extended without RSM | Up to 49.7 mi (80 km) |
Extended with RSM | Up to 34.2 mi (55 km) |
Calculated Link Distance | |
Extended without RSM | Up to 49.7 mi (80 km) |
Extended with RSM | Up to 34.2 mi (55 km) |
System Performance | |
Bit error ratio | 10-12 for all applications |
Applications | |
Supported applications | ATM, ESCON, Fast Ethernet, FDDI, Fibre Channel, OC-3, STM-1, plus proprietary protocols within the data range |
Reliability | |
MTBF5 at 77°F (25°C) | 1188655 hr |
FITs6 at 77°F (25°C) | 841 |
MTTR7 | 0.12 hr |
Description | Specification |
---|---|
Data Rate | |
Range | 100 to 1250 Mbps |
Local Link Ports 1 | |
Transmitter wavelength | 1260 to 1360 nm |
Receiver wavelength | 1260 to 1570 nm |
Receiver dynamic range | -7.0 to -21.0 dBm |
Transmitter output power | Standard: -6.0 to -12.0 dBm 622 ATM multimode with clock: -16.0 to -19.0 dBm |
Fiber type | Single mode or multimode |
Link distance | Single mode: 0.62 mi (1 km) Multimode: 0.12 mi (0.2 km) |
Connector type | MiniSC |
Remote Link Ports 1 | |
Wavelength | 1 to 32 channels, ranging from 1531.90 to 1558.98 nm according to ITU-T2 G.692 |
Receiver dynamic range | -7 to -30 dBm |
Transmitter Output Power (measured at WCM output) | |
Extended | 6.0 to 3.0 dBm |
Link Loss Budget3 | |
Extended without RSM | 5 to 22 dB |
Extended with RSM | Up to 15 dB |
Calculated Link Distance | |
Extended without RSM | Up to 49.7 mi (80 km) |
Extended with RSM | Up to 34.2 mi (55 km) |
System Performance | |
Bit error ratio | 10-12 for all applications 10-15 for ESCON4 |
Applications | |
Supported applications | ATM, ESCON, Fast Ethernet, Fibre Channel, FDDI, Gigabit Ethernet, OC-3/-12, STM-1/4, coupling link5, plus proprietary protocols within the data range |
Reliability | |
MTBF6 at 77°F (25°C) | 1188655 hr |
FITs7 at 77°F (25°C) | 841 |
Description | Specification |
---|---|
Clock data rates | 622 Mbps |
Local Link Ports 1 | |
Transmitter wavelength | 1260 to 1310 nm |
Receiver wavelength | 1260 to 1570 nm |
Receiver dynamic range | -7.0 to -21.0 dBm |
Transmitter output power | -16.0 to -21.0 dBm |
Fiber type | Single mode or multimode |
Link distance | Single mode: 0.62 mi (1 km) Multimode: 0.12 mi (0.2 km) |
Connector type | MiniSC |
Remote Link Ports 1 | |
Wavelength | 1 to 32 channels, ranging from 1531.90 to 1600.60 nm according to ITU-T2 G.692 |
Transmitter Output Power (measured at WCM output) | |
Extended | 6.0 to 3.0 dBm |
Link Loss Budget3 | |
Extended without RSM | 5 to 22 dB |
Extended with RSM | Up to 15 dB |
Calculated Link Distance | |
Extended without RSM | Up to 49.7 mi (80 km) |
Extended with RSM | Up to 34.2 mi (55 km) |
System Performance | |
Bit error ratio | 10-12 for all applications 10-15 for ESCON4 |
Applications | |
Supported applications | ATM, OC-12, STM-4, plus proprietary protocols within the data range |
Reliability | |
MTBF5 at 77°F (25°C) | 1188655 hr |
FITs6 at 77°F (25°C) | 841 |
MTTR7 | 0.12 hr |
Description | Specification |
---|---|
Data Rate | |
Clock data rate | 1062 Mbps |
Local Link Ports 1 | |
Transmitter wavelength | 1260 to 1360 nm |
Receiver wavelength | 1260 to 1570 nm |
Receiver dynamic range | -3 to -17.0 dBm |
Transmitter output power | -6.0 to -12.0 dBm |
Fiber type | Single mode or multimode |
Link distance | Single mode: 0.62 mi (1 km) Multimode: 0.12 mi (0.2 km) |
Connector type | MiniSC |
Remote Link Ports 1 | |
Wavelength | 1 to 32 channels, ranging from 1531.90 to 1600.60 nm according to ITU-T2 G.692 |
Transmitter Output Power (measured at WCM output) | |
Extended | 6.0 to 3.0 dBm |
Link Loss Budget3 | |
Extended without RSM | 5 to 22 dB |
Extended with RSM | Up to 15 dB |
Calculated Link Distance | |
Extended without RSM | 15.54 mi (25 km) |
Extended with RSM | 15.54 mi (25 km) |
System Performance | |
Bit error ratio | 10-12 for all applications |
Applications | |
Supported applications | Coupling link |
Reliability | |
MTBF4 at 77°F (25°C) | 1188655 hr |
FITs5 at 77°F (25°C) | 841 |
MTTR6 | 0.12 hr |
Description | Specification |
---|---|
Data Rate | |
Clock data rates | 1062 Mbps, 1250 Mbps |
Local Link Ports 1 | |
Transmitter wavelength | 1260 to 1310 nm |
Receiver wavelength | 1260 to 1570 nm |
Receiver dynamic range | -7.0 to -21.0 dBm |
Transmitter output power | -6.0 to -12.0 dBm |
Fiber type | Single mode or multimode |
Link distance | Single mode: 0.62 mi (1 km) Multimode: 0.12 mi (0.2 km) |
Connector type | MiniSC |
Remote Link Ports 1 | |
Wavelength | 1 to 32 channels, ranging from 1531.90 to 1600.60 nm according to ITU-T2 G.692 |
Transmitter Output Power (measured at WCM output) | |
Extended | 6.0 to 3.0 dBm |
Link Loss Budget3 | |
Extended without RSM | 5 to 22 dB |
Extended with RSM | Up to 15 dB |
Calculated Link Distance | |
Extended without RSM | Up to 49.7 mi (80 km) |
Extended with RSM | Up to 34.2 mi (55 km) |
System Performance | |
Bit error ratio | 10-12 for all applications |
Applications | |
Supported applications | Fibre Channel, OC-12, STM-4, and proprietary protocols at the data rates |
Reliability | |
MTBF4 at 77°F (25°C) | 1188655 hr |
FITs5 at 77°F (25°C) | 841 |
MTTR6 | 0.12 hr |
Description | Specification |
---|---|
Data Rate | |
Clock data rate | 2.488 Gbps |
Local Link Ports 1 | |
Transmitter wavelength | 1260 to 1360 nm |
Receiver wavelength | 1260 to 1570 nm |
Receiver dynamic range | -3.0 to -18.0 dBm |
Transmitter output power | -3.0 to -10.0 dBm |
Fiber type | Single mode |
Link distance | Single mode: 1.24 mi (2 km) |
Connector type | MiniSC |
Remote Link Ports 1 | |
Wavelength | 1 to 32 channels, ranging from 1531.90 to 1600.60 nm according to ITU-T2 G.692 |
Transmitter Output Power (measured at WCM output) | |
Extended | 7.0 to 4.0 dBm |
Link Loss Budget3 | |
Extended without RSM | 8 to 17 dB |
Extended with RSM | Up to 10 dB |
Calculated Link Distance | |
Extended without RSM | Up to 37.28 mi (60 km) |
Extended with RSM | Up to 24.86 mi (40 km) |
System Performance | |
Bit error ratio | 10-12 for all applications |
Applications | |
Supported applications | OC-48, STM-16, plus proprietary protocols within the data range |
Reliability | |
MTBF4 at 77°F (25°C) | 1188655 hr |
FITs5 at 77°F (25°C) | 841 |
MTTR6 | 0.12 hr |
Description | Specification |
---|---|
Data Rate | |
Clock data rates | 1062.5 Mbps, 1250 Mbps |
Local Link Ports |
|
Transmitter wavelength | 830 to 860 nm |
Receiver wavelength | 770 to 860 nm |
Receiver dynamic range | -3.0 to -17.0 dBm |
Transmitter output power | 0.0 to -9.0 dBm |
Fiber type | Multimode |
Link distance | Multimode: 0.12 mi (0.2 km) |
Connector type | MiniSC |
Remote Link Ports of WDM Channel Module |
|
Wavelength | ITU-T1 G.692; 200-GHz channel spacing |
Transmitter output power (measured at WCM output) | 6.0 dBm to 3.0 dBm |
Remote Link Budget for 32-Channel System |
|
Link loss budget for 32-channel system with BSM but without RSM | 7 to 22 dB |
Link loss budget for 32-channel system with BSM and with RSM | 1 to 15 dB |
Calculated link distance (with 1550-nm range) with BSM but without RSM | Up to 43.49 mi (70 km) |
Calculated link distance (with 1550-nm range) with BSM and with RSM | Up to 31.07 mi (50 km) |
Connector type | MiniSC |
System Performance |
|
Bit error rate | £10-12 |
Applications |
|
Supported applications |
1ITU-T=International Telecommunications Union Telecommunication Standardization Sector |
Description | Specification |
---|---|
Environmental | |
Temperature | 41 to 113°F (5 to 45°C) |
Humidity (RH1), ambient (noncondensing) operating | 10 to 90 percent |
Physical Characteristics | |
Dimensions (H x W x D) | 233 mm x 8TE2 x 160 mm |
Connector type | MiniSC |
Power | |
Voltage | 5V |
Power consumption | 150W |
Local Link Ports | |
Clock data rate | 4 x 200 Mbps (4 ESCON3 channels) |
Transmitter wavelength range | 1260 to 1360 nm |
Receiver wavelength range | 1280 to 1570 nm |
Receiver dynamic range | -5.0 to -28.0 dBm |
Transmitter output power range standard | -16.0 to -21.0 dBm |
Fiber type | Multimode |
Link distance | 0.62.5 mi (1 km) |
Remote Link Ports | |
Clock data rate | 1250 Mbps |
Wavelength | ITU-T4 G.692; 200-GHz spacing |
Remote Fiber | |
Fiber type | Single mode |
Cladding diameter | 125 ± 1.0 micron |
Cutoff wavelength | <1260 nm |
Receiver dynamic range | -7.0 to -30.0 dBm |
Transmitter output power range standard | 6.0 to 3.0 dBm |
Remote Link Budget for 32 Channel System |
|
Link loss rate with BSM but without switch | 7 to 22 dB |
Link loss rate with BSM and with switch | 1 to 15 dB |
Calculated link distance without switch | Up to 43.49 mi (70 km) |
Calculated link distance with switch | Up to 31.07 mi (50 km) |
Insertion loss for BSM module as a pair | 4.3 dB |
Remote Link Budget for 8-Channel System Without BSM5 | |
Link loss range without switch | 11 to 26 dB |
Link loss range with switch | 5 to 19 dB |
Calculated link distance without switch | Up to 52.81 mi (85 km) |
Calculated link distance with switch | Up to 37.28 mi (60 km) |
Remote Link Budget with Converter Kit (patch cord with 1-dB fiber-optic isolator6) | |
Link loss range without switch | 12 to 30 dB |
Calculated link distance without switch | Up to 62.14 mi (100 km) |
Clock Options | |
Fixed clock | 200 Mbps |
System Performance | |
Bit error rate | £10-15 for ESCON |
Network Element Management Interface | |
SNMP interface | RS-232: connector SUB-D9 10BASE-T: connector RJ-45 |
Applications | |
Electrical multiplexing from one to four optical ESCON channels to one optical high-speed channel (Gigabit Ethernet) and electrical demultiplexing | |
Data direction | Bidirectional, two fibers |
Supported applications | ESCON |
System Configuration | |
Maximum (managed, protected) | 32 x TDM channel module 4 x ESCON |
| 4 x multiplexer module |
| 1 x remote switch module |
| 1 x band splitter module |
| 4 x NEMI |
| 4 x DEMI |
| 8 x Frame AC or DC version |
Minimum (unmanaged, unprotected) | 1 x TDM channel module 4 x ESCON |
| 1 x converter card option |
| 1 x frame AC or DC version |
| Mixed configurations of TDM channel modules and WDM channel modules within one frame or between frames are allowed in Release 2.0 |
Table A-11 lists the specifications of the optical isolator.
Description | Specification |
---|---|
Wavelength band | 1520 to 1620 nm |
Typical peak isolation | 53 dB minimum |
Minimum isolation | 32 dB minimum |
Typical insertion loss | 0.7 dB |
Maximum insertion loss | 1.2 dB maximum |
Return loss | 58 dB minimum |
PDL1 | 0.15 dB maximum |
PMD2 | 0.07 ps3 maximum |
Maximum optical power | 300 mW |
Maximum tensile load | 5 N4 |
Operating temperature | -20 to + 60°C |
Storage temperature | -40 to + 85°C |
Fiber length | 1 m |
Four MUX and DMX pairs are supported, one set for the primary chassis and one set each for extension chassis A, B, and C.
The primary chassis MUX and DMX pair described in Table A-12 supports up to eight WCMs with their associated wavelengths.
Description | Specification |
---|---|
Insertion loss | 10 dB maximum |
Channel insulation | 30 dB minimum |
WCM Channel Number | Wavelength (nm) |
1 | 1558.98 |
2 | 1557.36 |
3 | 1555.75 |
4 | 1554.13 |
5 | 1552.52 |
6 | 1550.92 |
7 | 1549.32 |
8 | 1547.72 |
The extension chassis A MUX and DMX pair described in Table A-13 supports up to eight WCMs with their associated wavelengths.
Description | Specification |
---|---|
Insertion loss | 10 dB maximum |
Channel insulation | 30 dB minimum |
WCM Channel Number | Wavelength (nm) |
9 | 1542.94 |
10 | 1541.35 |
11 | 1539.77 |
12 | 1538.19 |
13 | 1536.61 |
14 | 1535.04 |
15 | 1533.47 |
16 | 1531.90 |
The extension chassis B MUX and DMX pair described in Table A-14 supports up to eight WCMs with their associated wavelengths.
Description | Specification |
---|---|
Insertion loss | 10 dB maximum |
Channel insulation | 30 dB minimum |
WCM Channel Number | Wavelength (nm) |
17 | 1572.06 |
18 | 1573.71 |
19 | 1575.37 |
20 | 1577.03 |
21 | 1578.69 |
22 | 1580.35 |
23 | 1582.02 |
24 | 1583.69 |
The extension chassis C MUX and DMX pair described in Table A-15 supports up to eight WCMs with their associated wavelengths.
Description | Specification |
---|---|
Insertion loss | 10 dB maximum |
Channel insulation | 30 dB minimum |
WCM Channel Number | Wavelength (nm) |
25 | 1588.73 |
26 | 1590.41 |
27 | 1592.10 |
28 | 1593.79 |
29 | 1595.49 |
30 | 1597.19 |
31 | 1598.89 |
32 |
Table A-16 describes BSM support for four groups with the following wavelength ranges.
Description | Specification |
---|---|
Group | Wavelength Range (nm) |
Insertion loss | 2 dB maximum |
Channel insulation | 30 dB maximum |
1 to 8 | 1547 to 1559 |
9 to 16 | 1531 to 1544 |
17 to 24 | 1571 to 1585 |
25 to 32 | 1588 to 1601 |
Table A-17 lists the RSM specifications.
Description | Specification |
---|---|
Fiber route diversity | 1:1 Protection |
Switch over time | <50 ms |
Insertion loss | 2 dB maximum |
Insulation | 30 dB minimum |
Table A-18 describes the hardware, interface, and software specifications for the NEMI.
Description | Specification |
---|---|
Hardware | |
RAM | 16 MB |
Flash | 24 MB |
Processor | AMD 486, 133 MHz |
WatchDog | Yes |
BIOS | Year 2000 compliant |
Interfaces | |
EIA/TIA-232 | 38.4 Kbps with a direct connection over LapLink cable, PPP connection over a leased line, or dial in using a modem |
Network interface | Personal Computer Interconnect (PCI) 10 Mbps |
BUS 1 | Proprietary |
BUS 2 | Proprietary |
Software | |
OS | LINUX 2.0.35 |
Protocols | PPP, FTP, Telnet, SNMP |
Applications | Netconfig, SNMP config, ocmstate |
SNMP provides an upgrade path for application software. The reprogramming of the Flash disk over Ethernet or serial port service depends on a maintenance contract. Table A-19 shows the SNMP configuration data.
Note All data marked Automatic read is automatically supplied to the NEMI. |
Feature | SNMP Management |
---|---|
WCM | |
Serial no. | Automatic read |
Channel location | Automatic read |
Clock (yes/no) | Automatic read |
Cooled laser (yes/no) | Automatic read |
Chassis | |
Power supply available (yes/no) | Automatic read |
Fan available (yes/no) | Automatic read |
Table A-20 shows the SNMP monitoring of technical operating conditions.
Feature | SNMP Management |
---|---|
Generally | |
Power supply failure (yes/no) | Automatic read |
Fan failure (yes/no) | Automatic read |
Environmental temperature (of converter card) | Automatic read |
Laser temperature | Automatic read |
Laser current | Automatic read |
Local Receiver | |
Loss of signal | Read |
Remote Receiver | |
Loss of signal | Read |
Local Transmitter | |
Status of laser (on/off) | Read |
Remote Transmitter | |
Status of laser (on/off) | Read |
Multiclock | |
Enable (on/off) | Read/write 1 |
Read clock setting | Read |
Set clock to 125, 155, 200, 266 Mbps | Write 1 |
Clock Synchronized (yes/no) |
1We do not recommend this option because SNMP does not require a password. Use Telnet when a password requirement exists. |
Table A-21 shows the specifications for the DEMI.
Note All data access is performed through the NEMI. |
Description | Specification |
---|---|
Interfaces | |
BUS 1 | Proprietary |
BUS 2 | Proprietary |
Posted: Thu Aug 9 15:48:05 PDT 2001
All contents are Copyright © 1992--2001 Cisco Systems, Inc. All rights reserved.
Important Notices and Privacy Statement.