This chapter describes the specifications for the Cisco Metro 1500 series system. This chapter includes the following sections:
Cisco Metro 1500 series system is configured with one primary chassis and up to three extension chassis.
Standard Configuration
Configuration Options
Standard Configuration
Configuration Options
Standard Configuration
Configuration Option
Standard Configuration
Configuration Option
The primary chassis and the extension chassis are built on the same chassis. Table 10-1 lists the chassis specifications for the Cisco Metro 1500 series system.
Description | Specification |
Width | 440 (482) mm |
Length | 305 mm |
Height | 222 mm |
Operation temperature | 5 to 45°C (long term conditions) |
Storage temperature | -10 to 70°C |
Transportation temperature | -10 to 70°C |
Humidity | 10 to 90% RH noncondensing |
MTBF at 25°C | 442488 hr |
FITs at 25°C | 2260 |
MTTR | 0.34 hr |
Voltage | 110-120/210-240 VAC 50/60 Hz auto switching |
Voltage range | 99-127.2/189-254.4 V AC |
Current max. | 2.5A AC |
Power consumption max. | Max. 150 VA |
Fuses | 2.5A, 250V, slow blowing, 5x20 mm (for AC version) |
Description | Specification |
Weight | Max. 25 kg |
Fans | Two redundant fans |
Power supplies | Two redundant power supplies |
The Cisco Metro 1500 series system supports nine different WCM configurations. These cards support only extended reach lasers. See Table 10-2 through Table 10-7.
Data Rate | |
Range | 10 to 200 Mbps |
Local Link Ports 1 | |
Transmitter wavelength | 1260 to 1310 nm |
Receiver wavelength | 1260 to 1570 nm |
Receiver dynamic range | -5.0 to -28.0 dBm |
Transmitter output power | -16.0 to -21.0 dBm |
Fiber type | Single mode or multimode |
Link distance | 1 km (single mode) or 0.2 km (multimode) |
Connector type | MiniSC |
Remote Link Ports 1 | |
Wavelength | 1 to 32 in the range from 1531.90 to 1600.60 nm according to ITU-T G.692 |
Transmitter Output Power (measured at WCM output) | |
Extended | +6.0 to +3.0 dBm |
Link Loss Budget | |
Extended without RSM | 5 to 22 dB |
Extended with RSM | Up to 15 dB |
Calculated Link Distance | |
Extended without RSM | Up to 80 km |
Extended with RSM | Up to 55 km |
System Performance | |
Bit error ratio | 10-12 for all applications |
Applications | |
Supported applications | FDDI, Fast Ethernet, ATM, OC-3, STM-1, ESCON, fiber channel, plus proprietary protocols within the data range |
Reliability | |
Mean time between failure (MTBF) at 25°C | 1188655 hr |
FITs at 25°C | 841 |
Mean time to repair (MTTR) | 0.12 hr |
1Local and remote optical loop only, specified for test and installation purposes only. |
Data Rate | |
Range | 100 to 1250 Mbps |
Local Link Ports 1 | |
Transmitter wavelength | 1260 to 1310 nm |
Receiver wavelength | 1260 to 1570 nm |
Receiver dynamic range | -7.0 to -21.0 dBm |
Transmitter output power | -6.0 to -12.0 dBm |
Fiber type | Single mode or multimode |
Link distance | 1 km (single mode) or 0.2 km (multimode) |
Connector type | MiniSC |
Remote Link Ports 1 | |
Wavelength | 1 to 32 in the range from 1531.90 to 1600.60 nm according to ITU-T G.692 |
Transmitter Output Power (measured at WCM output) | |
Extended | +6.0 to +3.0 dBm |
Link Loss Budget | |
Extended without RSM | 5 to 22 dB |
Extended with RSM | Up to 15 dB |
Calculated Link Distance | |
Extended without RSM | Up to 80 km |
Extended with RSM | Up to 55 km |
System Performance | |
Bit error ratio | 10-12 for all applications |
Applications | |
Supported applications | FDDI, Fast Ethernet, Gigabit Ethernet, ATM, OC-3/-12, STM-1/-4, ESCON, Fiber channel, coupling link 2, plus proprietary protocols within the data range |
Reliability | |
Mean time between failure (MTBF) at 25°C | 1188655 hr |
FITs at 25°C | 841 |
Mean time to repair (MTTR) | 0.12 hr |
1Local and remote optical loop only, specified for test and installation purposes only. 2Max. link distance 25 km; local receiver dynamic range: -3 dBm to -17 dBm. |
Data Rate | |
Clock Data Rates | 622 Mbps |
Local Link Ports 1 | |
Transmitter wavelength | 1260 to 1310 nm |
Receiver wavelength | 1260 to 1570 nm |
Receiver dynamic range | -7.0 to -21.0 dBm |
Transmitter output power | -16.0 to -21.0 dBm |
Fiber type | Single mode or multimode |
Link distance | 1 km (single mode) or 0.2 km (multimode) |
Connector type | MiniSC |
Remote Link Ports 1 | |
Wavelength | 1 to 32 in the range from 1531.90 to 1600.60 nm according to ITU-T G.692 |
Transmitter Output Power (measured at WCM output) | |
Extended | +6.0 to +3.0 dBm |
Link Loss Budget | |
Extended without RSM | 5 to 22 dB |
Extended with RSM | Up to 15 dB |
Calculated Link Distance | |
Extended without RSM | Up to 80 km |
Extended with RSM | Up to 55 km |
System Performance | |
Bit error ratio | 10-12 for all applications |
Applications | |
Supported Applications | ATM, OC-12, STM-4, plus proprietary protocols within the data range |
Reliability | |
Mean time between failure (MTBF) at 25°C | 1188655 hr |
FITs at 25°C | 841 |
Mean time to repair (MTTR) | 0.12 hr |
1Local and remote optical loop only, specified for test and installation purposes only. |
Data Rate | |
Clock data rates | 1062 Mbps |
Local Link Ports 1 | |
Transmitter wavelength | 1260 to 1360 nm |
Receiver wavelength | 1260 to 1570 nm |
Receiver dynamic range | -3 to -17.0 dBm |
Transmitter output power | -6.0 to -12.0 dBm |
Fiber type | Single mode or multimode |
Link distance | 1 km (single mode) or 0.2 km (multimode) |
Connector type | MiniSC |
Remote Link Ports 1 | |
Wavelength | 1 to 32 in the range from 1531.90 to 1600.60 nm according to ITU-T G.692 |
Transmitter Output Power (measured at WCM output) | |
Extended | +6.0 to +3.0 dBm |
Link Loss Budget | |
Extended without RSM | 5 to 22 dB |
Extended with RSM | Up to 15 dB |
Calculated Link Distance | |
Extended without RSM | 25 km |
Extended with RSM | 25 km |
System Performance | |
Bit error ratio | 10-12 for all applications |
Applications | |
Supported applications | Coupling Link |
Reliability | |
Mean time between failure (MTBF) at 25°C | 1188655 hr |
FITs at 25°C | 841 |
Mean time to repair (MTTR) | 0.12 hr |
1Local and remote optical loop only, specified for test and installation purposes only. |
Data Rate | |
Clock data rates | 1062, 1250 Mbps |
Local Link Ports 1 | |
Transmitter wavelength | 1260 to 1310 nm |
Receiver wavelength | 1260 to 1570 nm |
Receiver dynamic range | -7.0 to -21.0 dBm |
Transmitter output power | -6.0 to -12.0 dBm |
Fiber type | Single mode or multimode |
Link distance | 1 km (single mode) or 0.2 km (multimode) |
Connector type | MiniSC |
Remote Link Ports 1 | |
Wavelength | 1 to 32 in the range from 1531.90 to 1600.60 nm according to ITU-T G.692 |
Transmitter Output Power (measured at WCM output) | |
Extended | +6.0 to +3.0 dBm |
Link Loss Budget | |
Extended without RSM | 5 to 22 dB |
Extended with RSM | Up to 15 dB |
Calculated Link Distance | |
Extended without RSM | Up to 80 km |
Extended with RSM | Up to 55 km |
System Performance | |
Bit error ratio | 10-12 for all applications |
Applications | |
Supported applications | Fiber channel, OC-12, STM-4, and proprietary protocols at the data rates. |
Reliability | |
Mean time between failure (MTBF) at 25°C | 1188655 hr |
FITs at 25°C | 841 |
Mean time to repair (MTTR) | 0.12 hr |
1Local and remote optical loop only, specified for test and installation purposes only. |
Data Rate | |
Clock data rate | 2.488 Gbps |
Local Link Ports 1 | |
Transmitter wavelength | 1260 to 1360 nm |
Receiver wavelength | 1260 to 1570 nm |
Receiver dynamic range | -3.0 to -18.0 dBm |
Transmitter output power | -3.0 to -10.0 dBm |
Fiber type | Single mode |
Link distance | 2 km |
Connector type | MiniSC |
Remote Link Ports 1 | |
Wavelength | 1 to 32 in the range from 1531.90 to 1600.60 nm according to ITU-T G.692 |
Transmitter Output Power (measured at WCM output) | |
Extended | +7.0 to -4.0 dBm |
Link Loss Budget | |
Without RSM | 8 to 17 dB |
With RSM | Up to 10 dB |
Calculated Link Distance | |
Without RSM | Up to 60 km |
With RSM | Up to 40 km |
System Performance | |
Bit error ratio | 10-12 for all applications |
Applications | |
Supported applications | OC-48, STM-16, plus proprietary protocols within the data range |
Reliability | |
Mean time between failure (MTBF) at 25°C | 1188655 hr |
FITs at 25°C | 841 |
Mean time to repair (MTTR) | 0.12 hr |
1Local and remote optical loop only, specified for test and installation purposes only. |
Specification | Description |
---|---|
Data Rate | |
Rates | 1062.5 Mbps, 1250 Mbps |
Local Link Ports |
|
Transmitter wavelength | 830 to 860 nm |
Receiver wavelength | 770 to 860 nm |
Receiver dynamic range | -3.0 to -17.0 dBm |
Transmitter output power | 0.0 to -9.0 dBm |
Fiber type | Multimode |
Link distance | 0.2 km (multimode) |
Connector type | MiniSC |
Remote Link Ports of WDM Channel Module |
|
Wavelength | ITU-T1 G.692; 200-GHz channel spacing |
Transmitter output power (measured at WCM output) | 6.0 dBm to 3.0 dBm |
Remote link budget for 32 channel system |
|
Link loss budget for 32-channel system with BSM but without RSM | 7 to 22 dB |
Link loss budget for 32-channel system with BSM and with RSM | 1 to 15 dB |
Calculated link distance (with 1550-nm range) with BSM but without RSM | Up to 70 km (43.49 miles) |
Calculated link distance (with 1550-nm range) with BSM and with RSM | Up to 50 km (31.07 miles) |
Connector type | MiniSC |
System Performance |
|
Bit error rate | <=10-12 |
Applications |
|
Supported applications | Gigabit Ethernet, fiber channel |
1ITU-T=International Telecommunications Union Telecommunication Standardization Sector. |
Four MUX and DMX pairs are supported, one set for the primary chassis and one set each for extension chassis A, B, and, C.
The primary chassis MUX and DMX pair described in Table 10-9 supports up to eight WCMs with their associated wavelengths.
WCM Channel Number | Wavelength (nm) |
---|---|
1 | 1558.98 |
2 | 1557.36 |
3 | 1555.75 |
4 | 1554.13 |
5 | 1552.52 |
6 | 1550.92 |
7 | 1549.32 |
8 | 1547.72 |
Specification | |
Insertion loss | Max. 10 dB |
Channel insulation | Min. 30 dB |
The extension chassis A MUX and DMX pair described in Table 10-10 supports up to eight WCMs with their associated wavelengths.
WCM Channel Number | Wavelength (nm) |
---|---|
9 | 1542.94 |
10 | 1541.35 |
11 | 1539.77 |
12 | 1538.19 |
13 | 1536.61 |
14 | 1535.04 |
15 | 1533.47 |
16 | 1531.90 |
Specification | |
Insertion loss | Max. 10 dB |
Channel insulation | Min. 30 dB |
The extension chassis B MUX and DMX pair described in Table 10-11 supports up to eight WCMs with their associated wavelengths.
WCM Channel Number | Wavelength (nm) |
---|---|
17 | 1572.06 |
18 | 1573.71 |
19 | 1575.37 |
20 | 1577.03 |
21 | 1578.69 |
22 | 1580.35 |
23 | 1582.02 |
24 | 1583.69 |
Specification | |
Insertion loss | Max. 10 dB |
Channel insulation | Min. 30 dB |
The extension chassis C MUX and DMX pair described in Table 10-12 supports up to eight WCMs with their associated wavelengths.
WCM Channel Number | Wavelength (nm) |
---|---|
25 | 1588.73 |
26 | 1590.41 |
27 | 1592.10 |
28 | 1593.79 |
29 | 1595.49 |
30 | 1597.19 |
31 | 1598.89 |
32 | 1600.60 |
Specification | |
Insertion loss | Max. 10 dB |
Channel insulation | Min. 30 dB |
Table 10-13 describes BSM support for four groups with the following wavelength ranges.
Group | Wavelength Range (nm) |
---|---|
1 to 8 | 1547 to 1559 |
9 to 16 | 1531 to 1544 |
17 to 24 | 1571 to 1585 |
25 to 32 | 1588 to 1601 |
Specification | |
Insertion loss | Max. 2 dB |
Channel insulation | Min. 30 dB |
Table 10-14 shows the RSM specifications.
Specification | |
---|---|
Fiber route diversity | 1:1 Protection |
Switch over time | < 50 ms |
Insertion loss | Max. 2 dB |
Insulation | Min. 30 dB |
Table 10-15 describes the NEMI hardware, interface, and software specifications.
Specification | |
---|---|
Hardware | |
RAM | 16 MB |
Flash | 12 MB |
Processor | AMD 486, 133 MHz |
WatchDog | Yes |
BIOS | Year 2000 compliant |
Interfaces | |
EIA/TIA-232 | 38.4 kbps with a direct connection over Laplink cable, PPP connection over a leased line, or dial in using a modem |
Net interface | Personal Computer Interconnect network interface (PCI) 10 Mbps |
BUS 1 | Proprietary |
BUS 2 | Proprietary |
Software | |
OS | LINUX 2.0.35 |
Protocols | PPP, FTP, Telnet, SNMP |
Applications | Netconfig, SNMP config, ocmstate |
SNMP provides an upgrade path for application software. The reprogramming of the Flash disk over Ethernet or serial port service depends on a maintenance contract. Table 10-16 shows the SNMP configuration data.
Note All data marked Automatic read is automatically supplied to the NEMI. |
Feature | SNMP Management |
---|---|
WCM | |
Serial no. | Automatic read |
Channel location | Automatic read |
Clock (yes/no) | Automatic read |
Cooled laser (yes/no) | Automatic read |
Chassis | |
Power supply available (yes/no) | Automatic read |
Fan available (yes/no) | Automatic read |
Table 10-17 shows the SNMP monitoring of technical operation conditions.
Feature | SNMP Management |
---|---|
Generally | |
Power supply failure (yes/no) | Automatic read |
Fan failure (yes/no) | Automatic read |
Environmental temperature (of converter card) | Automatic read |
Laser temperature | Automatic read |
Laser current | Automatic read |
Local Receiver | |
Loss of signal | Read |
Remote Receiver | |
Loss of signal | Read |
Local Transmitter | |
Status of laser (on/off) | Read |
Remote Transmitter | |
Status of laser (on/off) | Read |
Multiclock | |
Enable (on/off) | Read/write 1 |
Read clock setting | Read |
Set clock to 125, 155, 200, 266 Mbps | Write 1 |
Clock Synchronized (yes/no) | Read specification |
1This is not recommended because SNMP does not require a password. Use Telnet when a password requirement exists. |
Table 10-18 shows the DEMI specifications.
Note All data access is performed through the NEMI. |
Interfaces | |
---|---|
BUS 1 | Proprietary |
BUS 2 | Proprietary |
Posted: Tue Jan 23 11:22:57 PST 2001
All contents are Copyright © 1992--2001 Cisco Systems, Inc. All rights reserved.
Important Notices and Privacy Statement.