Troubleshooting 10-Gbps ITU Trunk Card Problems
9.2 Initial Troubleshooting Checklist
9.3 Troubleshooting 10-Gbps ITU Trunk Card Interface Problems
9.3.1 Waveethernetphy Interface Down and Shows Loss of Lock
9.3.2 Waveethernetphy Interface Down and Shows Loss of Sync
9.3.3 CVRD Errors on the Waveethernetphy Interface
9.3.4 CRC and CDL HEC Errors on the Waveethernetphy Interface
9.3.5 Ethernetdcc Interface Down
9.4 Troubleshooting 10-Gbps ITU Trunk Card Problems Using Loopbacks
Troubleshooting 10-Gbps ITU Trunk Card Problems
This chapter describes how to troubleshoot 10-Gbps ITU trunk card problems. This chapter includes the following sections:
• Overview
• Initial Troubleshooting Checklist
• Troubleshooting 10-Gbps ITU Trunk Card Interface Problems
• Troubleshooting 10-Gbps ITU Trunk Card Problems Using Loopbacks
9.1 Overview
The 10-Gbps ITU trunk card converts up to four aggregated signals to an ITU-compliant wavelength, or channel.
Figure 9-1 shows the interfaces for the splitter 10-Gbps ITU trunk card. Figure 9-2 shows the interfaces for the nonsplitter 10-Gbps ITU trunk card.
Figure 9-1 Splitter 10-Gbps ITU Trunk Card Interfaces
Figure 9-2 Nonsplitter 10-Gbps ITU Trunk Card Interfaces
9.2 Initial Troubleshooting Checklist
Follow this initial checklist before proceeding with the troubleshooting procedures:
•Check that the receive signal power level is between -22 dBm and -6 dBm.
•Issue show interfaces commands to ensure that the waveethernetphy and wavepatch interfaces are administratively up, that there are no errors on the interfaces, and that the ITU laser is up.
•Issue a show connect command to verify the status of the cross connections to the aggregation cards.
•Check that the LEDs on the cards show the proper state.
•Issue a show facility-alarm status command to display the alarms on the interfaces.
•Issue the show hardware linecard command to verify the 10-Gbps ITU trunk card functional image.
•Check that the 10-Gbps ITU trunk cards are patched to the correct OADM ports. Issue a show patch command to verify that there are no frequency mismatches.
•Ensure that all optical connectors are clean. Refer to the Cisco ONS 15530 Cleaning Procedures for Fiber Optic Connections document.
9.3 Troubleshooting 10-Gbps ITU Trunk Card Interface Problems
This section contains troubleshooting procedures for 10-Gbps ITU trunk card interface problems.
9.3.1 Waveethernetphy Interface Down and Shows Loss of Lock
Symptom A waveethernetphy interface is down and signal quality status shows Loss of Lock.
Table 9-1 describes the potential causes of the symptom and the solutions.
9.3.2 Waveethernetphy Interface Down and Shows Loss of Sync
Symptom A waveethernetphy interface is down and signal quality status shows Loss of Sync.
Table 9-1 describes the potential causes of the symptom and the solution.
9.3.3 CVRD Errors on the Waveethernetphy Interface
Symptom The waveethernetphy interface is in a down state and in the show interfaces command output the Code violation and running disparity error count (64b66b CVRD) field are increasing and the Signal Condition field shows "Signal Fail Threshold exceeded."
Table 9-3 describes the potential causes of the symptom and the solutions.
9.3.4 CRC and CDL HEC Errors on the Waveethernetphy Interface
Symptom The waveethernetphy interface is in a down state, the CRC error count and the CDL HEC error counts in the show interfaces command output is increasing, and the Signal Condition field shows "Signal Fail Threshold exceeded" or "Signal Degrade Threshold exceeded."
Table 9-4 describes the potential causes of the symptom and the solutions.
Table 9-4 CRC and CDL HEC Errors on the Waveethernetphy Interface
Possible Problem SolutionThe data is corrupted somewhere in the data path.
1. Perform a loopback on the signal path to isolate the area where the data is corrupted. For information on performing loopbacks, see the "Troubleshooting 10-Gbps ITU Trunk Card Problems Using Loopbacks" section.
2. Issue show interfaces commands for all the interfaces in the signal path. Resolve any error conditions or configuration problems encountered.
9.3.5 Ethernetdcc Interface Down
Symptom The ethernetdcc interface is down and pings across the interface fail.
Table 9-5 describes the potential cause of the symptom and the solution.
9.4 Troubleshooting 10-Gbps ITU Trunk Card Problems Using Loopbacks
This section describes how to use software loopbacks to perform fault isolation for signals on 10-Gbps ITU trunk cards. The 10-Gbps ITU trunk card supports two types of software loopbacks:
•Facility loopbacks
•Terminal loopbacks
9.4.1 Facility Loopbacks
A facility loopback verifies the functioning of the 10-Gbps ITU trunk card from the trunk side (see Figure 9-3).
Figure 9-3 Facility Loopback Example on a 10-Gbps ITU Trunk Card
To create a facility loopback
Step 1 Issue a loopback facility command on the waveethernetphy interface.
Step 2 Check that the signal reaches the system at the far end.
Step 3 If the signal does not reach the far end, check the trunk fiber and the interfaces along the signal path. If the fiber is intact, replace the card.
9.4.2 Terminal Loopbacks
A terminal loopback verifies the functioning of the 10-Gbps ITU trunk card from the switch fabric side (see Figure 9-4).
Figure 9-4 Terminal Loopback Example on a 10-Gbps ITU Trunk Card
To create a terminal loopback:
Step 1 Issue a loopback terminal command on the waveethernetphy interface.
Step 2 Check that the traffic is reaching the client equipment.
Step 3 If the signal does not reach the client equipment, replace the card.