cc/td/doc/product/mels/15530
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table Of Contents

Specifications

Chassis Specifications

Channel to Wavelength Mapping

OADM Module Specifications

PSM Specifications

OSC Module Specifications

PB-OE and WB-VOA Module Specifications

Transponder Line Card Specifications

ESCON Aggregation Card Specifications

4-Port 1-Gbps/2-Gbps FC Aggregation Card

8-Port FC/GE Aggregation Card

8-Port Multi-Service Muxponder Specifications

SDI Jitter Performance

2.5-Gbps ITU Trunk Card Specifications

10-Gbps ITU Tunable and Non tunable Trunk Card Specifications

10-Gbps Uplink Card

SFP Specifications


Specifications


This appendix describes the specifications for the chassis, line cards, and the carrier motherboard and modules used in the Cisco ONS 15530 system. This appendix includes the following sections:

Chassis Specifications

Channel to Wavelength Mapping

OADM Module Specifications

PSM Specifications

OSC Module Specifications

PB-OE and WB-VOA Module Specifications

Transponder Line Card Specifications

ESCON Aggregation Card Specifications

4-Port 1-Gbps/2-Gbps FC Aggregation Card

8-Port FC/GE Aggregation Card

8-Port Multi-Service Muxponder Specifications

2.5-Gbps ITU Trunk Card Specifications

10-Gbps ITU Tunable and Non tunable Trunk Card Specifications

10-Gbps Uplink Card

SFP Specifications


Note Cisco recommends you to use the Cisco MetroPlanner tool to design your DWDM networks. For more information about optical power budgets and network planning, refer to the Cisco ONS 15530 Planning Guide and the Cisco MetroPlanner DWDM Operations Guide.


Chassis Specifications

Table A-1 lists the specifications for the Cisco ONS 15530.

Table A-1 Cisco ONS 15530 Specifications 

Description
Specification
Environmental

Temperature, ambient operating

32 to 104°F (0 to +40°C)

Humidity (RH1 ), ambient (non- condensing) operating

5 to 95%

Altitude, operating and non-operating

Minimum -197 ft (-60 m)
Maximum 6500 ft (2000 m)

Cisco ONS 15530 CHAS-E

Dimensions (H x W x D)

14.4 x 17.3 x 10.1 in.
(365.9 x 439.4 x 256.5 mm)

Weight

Empty chassis: 27.5 lbs (12.25 kg)
Fully loaded: 71 lbs (32.21 kg)

Cisco ONS 15530 CHAS-N

Dimensions (H x W x D)

15.7 x 17.3 x 10.1 in.
(398.8 x 439.4 x 256.5 mm)

Weight

Empty chassis: 27.0 lbs (12.25 kg)
Fully loaded: 71 lbs (32.21 kg)

AC-Input Power

AC-input voltage

100 to 240 VAC (nominal)
85 to 264 VAC (full range)

Power consumption maximum

600W

Heat dissipation

2048 BTU/hr

DC-Input Power

DC-input voltage

-48 to -60 VDC (nominal)
-40.5 to -72 VDC (full range)

Power consumption maximum

600W (fully configured system)

Heat dissipation

2048 BTU/hr

1 RH = relative humidity


Channel to Wavelength Mapping

Table A-2 lists the channels, wavelengths, and frequencies for each band.

Table A-2 Channel to Wavelength Mapping 

Cisco ONS 15530
Band
Cisco ONS 15530
Channel
ITU1 Channel
ITU Wavelength2
ITU Frequency3

OSC4

 

19

1562.23

191.9000

A

1

21

1560.61

192.100

2

22

1559.79

192.200

3

23

1558.98

192.300

4

24

1558.17

192.400

B

5

26

1556.55

192.600

6

27

1555.75

192.700

7

28

1554.94

192.800

8

29

1554.13

192.900

C

9

31

1552.52

193.100

10

32

1551.72

193.200

11

33

1550.92

193.300

12

34

1550.12

193.400

D

13

36

1548.51

193.600

14

37

1547.72

193.700

15

38

1546.92

193.800

16

39

1546.12

193.900

E

17

41

1544.53

194.100

18

42

1543.73

194.200

19

43

1542.94

194.300

20

44

1542.14

194.400

F

21

46

1540.56

194.600

22

47

1539.77

194.700

23

48

1538.98

194.800

24

49

1538.19

194.900

G

25

51

1536.61

195.100

26

52

1535.82

195.200

27

53

1535.04

195.300

28

54

1534.25

195.400

H

29

56

1532.68

195.600

30

57

1531.90

195.700

31

58

1531.12

195.800

32

59

1530.33

195.900

1 ITU = International Telecommunication Union

2 Wavelengths in vacuum in nm

3 Frequency in THz, 100 GHz grid

4 OSC = optical supervisory channel


OADM Module Specifications

Table A-3 shows the maximum optical link loss for the data channels between the 4-channel OADM modules and the line cards, and between the pass-through add and drop connectors on the OADM modules.


Note The optical specifications described in this section are only for the individual components and should not be used to characterize the entire network performance.


Table A-3 OADM Module Specifications  

Type of OADM Modules
Trunk IN to Line Card
(Data Drop)
Line Card to
Trunk OUT (Data Add)
Trunk IN to Thru OUT
(Pass-Through Drop)
Thru IN to
Trunk OUT (Pass-Through Add)

4-channel with OSC

4.1 dB

4.1 dB

1.5 dB

1.5 dB

4-channel
without OSC

4.1 dB

4.1 dB

1.0 dB

1.0 dB


PSM Specifications

Table A-4 and Table A-5 lists the PSM (protection switch module) card and optical specifications for the Cisco ONS 15530.


Note The optical specifications described in this section are only for the individual components and should not be used to characterize the entire network performance.


Table A-4 PSM Card Specifications 

Description
Specification

Dimensions

3.7 x 9 in. (9.4 x 22.9 cm)

Weight

3.5 lbs (1.59 kg)

Connector

MU

Receive overload

17 dBm


Table A-5 PSM Optical Specifications 

Port
Insertion Loss
Minimum (dB)
Maximum (dB)
Ripple (dB)

Rx_West to monitor

19

21

0.5

Rx_West to common out

 

1.7

0.4

Rx_East to monitor

19

21

0.5

Rx_East to common out

 

1.7

0.4

TX_Common to Tx_West

2.7

3.7

0.3

Tx_Common to Tx_East

2.7

3.7

0.3



Note The accuracy of the power detector is ±1.9 dB over the entire C band and temperature range.


OSC Module Specifications

Table A-6 lists the OSC module receiver and transmitter specifications.


Note The optical specifications described in this section are only for the individual components and should not be used to characterize the entire network performance.


Table A-6 OSC Module Specifications 

Description
Specification

Fiber type

SM1 9 micron

Connector

MU

Output wavelength

1562.23 ITU channel

Receiver
Minimum
Maximum

Receive sensitivity

-19 dBm

 

Receive overload

 

-1.5 dBm

Input wavelength

1249 nm

1600 nm

Transmitter
Minimum
Maximum

Transmitter power

5 dBm

10 dBm

Dispersion tolerance

 

3200 ps/nm

1 SM = single mode.


PB-OE and WB-VOA Module Specifications

Table A-7 contains specifications for the Cisco ONS 15530 single-band PB-OE module. Table A-8 contains specifications for the Cisco ONS 15530 single and dual WB-VOA modules.


Note The optical specifications described in this section are only for the individual components and should not be used to characterize the entire network performance.


Table A-7 Cisco ONS 15530 Single-Band and Dual-Band PB-OE Module Specifications 

Parameter
Specification

Maximum attenuation

30 dB

Attenuation resolution

0.1 dB

In-out isolation for drop/equalized band path

50 dB

In-out isolation for upgrade band path

50 dB

Input power range

-26 to 11 dBm


Table A-8 Cisco ONS 15530 Single and Dual WB-VOA Modules Specification 

Parameter
Specification

Operating wavelength range

1530 to 1565 nm

Maximum attenuation

30 dB

Attenuation resolution

0.1 dB

Input power range

-28 to 21 dBm


Transponder Line Card Specifications

Table A-9 lists the transponder line card receiver and transmitter specifications for the client side lasers.


Note The optical specifications described in this section are only for the individual components and should not be used to characterize the entire network performance.


Table A-9 Client Side Optical Specifications 

Description
Specification

Fiber type

SM1 9 micron

Connector

SC

Receiver
SM Minimum
SM Maximum
MM2 Minimum
MM Maximum

Receive sensitivity

-19 dBm

 

-25 dBm

 

Receive overload

 

-1.5 dBm

 

-8 dBm

Input wavelength

1249 to 1600 nm3

 

1249 to 1600 nm

 

Optical reflectance

-27 dB4

 

 

 

Receiver fiber pigtail

MM 50 micron

 

MM 62.5 micron

 
Transmitter
SM Minimum
SM Maximum
MM5 Minimum
MM Maximum

Output wavelength

1260 to 1360 nm

 

1260 to 1360 nm

 

Transmitter power

-5 dBm

0 dBm

-5 dBm

0 dBm

1 SM = single mode

2 MM = multimode

3 nm = nanometers

4 dB = decibels

5 MM = multimode


Table A-10 lists the transponder line card receiver and transmitter specifications for the trunk side lasers.


Note Optical loss due to splitter modules and connectors should be included in the optical budget calculation.


Table A-10 Trunk Side Optical Specifications 

Description
Specification

Fiber type

SM 9 micron

Connector

MU

Receiver
Minimum
Maximum

OSNR 1 , 2

19 dB

 

Receive sensitivity 2

-28 dBm

 

Receive overload

 

-8 dBm

Input wavelength

1260 nm

1580 nm

Transmitter
Minimum
Maximum

Transmitter power

5 dBm

10 dBm

Dispersion tolerance

 

3200 ps/nm3

1 OSNR = optical signal-to-noise ratio.

2 Add the proper network-level penalty to the OSNR and/or receive power based on your actual network topology characteristics, such as dispersion.

3 ps/nm = picoseconds per nanometer.


ESCON Aggregation Card Specifications

Table A-11 lists SFP optics supported by the 10-port ESCON aggregation card. The optical power characteristics of the supported SFP optics are listed in the SFP Specifications section.


Note The optical specifications described in this section are only for the individual components and should not be used to characterize the entire network performance.


Table A-11 SFPs Supported by ESCON Aggregation Cards

SFP Part Number
Description

15500-XVRA-01A2

ESCON, OC-3/ STM-1 SR

15500-XVRA-10A1

Low-band 8 Mbps to 200 Mbps

15500-XVRA-10B1

Low-band 8 Mbps to 200 Mbps

15500-XVRA-11A1

Mid-band 200 Mbps to 622 Mbps

15500-XVRA-11B1

Mid-band 200 Mbps to 1.25 Gbps

15500-XVRA-12B1

High-band 1.062 Gbps to 2.488 Gbps


Table A-12 lists the maximum added end-to-end latency is from the ESCON aggregation cards aggregating and separating the client signals.


Note The ESCON latency values have been determined by simulation and are approximate.


Table A-12 Latency for ESCON Aggregation Cards 

Traffic Mix on Transmitting Node
Maximum Added End-to-End Latency1
No GE
1518-Byte GE Packets
4470-Byte GE Packets
10,230-Byte GE Packets

ESCON only

8.5 µs

 

 

 

ESCON and FC/FICON on the same 10-Gbps ITU trunk card

8.5 µs

 

 

 

ESCON and GE only on the same 10-Gbps ITU trunk card

 

10 µs

12.5 µs

17 µs

1 The latency values are based on configuration of correct transmit buffer sizes as described in the Cisco ONS 15530 Configuration Guide.


4-Port 1-Gbps/2-Gbps FC Aggregation Card

The 4-port 1-Gbps/2-Gbps FC aggregation cards support the SFPs listed in Table A-13. The optical power characteristics of the supported SFPs are listed in the SFP Specifications section. Only use Cisco-certified SFPs for the 4-port 1-Gbps/2-Gbps FC aggregation cards. If the specifications of the client equipment interfaces do not fall within these ranges, attenuators or amplifiers might be required.


Note The optical specifications described in this section are only for the individual components and should not be used to characterize the entire network performance.


Table A-13 SFPs Supported by the 4-port 1-Gbps/2-Gbps FC Aggregation Card  

Part Number
Protocols or Clock Rate Range Supported

15500-XVRA-02C1

Gigabit Ethernet1 , Fibre Channel (1 Gbps)2 , FICON (1 Gbps)

15500-XVRA-03B1

Gigabit Ethernet3 , Fibre Channel (1 Gbps)4 , FICON (1 Gbps), ISC-3 links compatibility mode

15500-XVRA-03B2

Fibre Channel (1 Gbps and 2 Gbps), FICON (1 Gbps and 2 Gbps)

15500-XVRA-11B1

Mid-band variable rate 200 Mbps to 1.25 Gbps

15500-XVRA-12B1

High-band variable rate 1.062 Gbps to 2.488 Gbps

15454-SFP-GEFC-SX

Fibre Channel (2 Gbps), Fibre Channel (1 Gbps), Gigabit Ethernet, FICON (1 Gbps and 2 Gbps)

1 1000BASE-SX

2 FC-0-100-M5-SN-S and FC-0-100-M6-SN-S standards

3 1000BASE-LX

4 FC-0-100-SM-LC-S standard


Table A-14 and Table A-15 show the latency value for the various configurations on the transmitting node.

FC and FICON traffic on interfaces with buffer credits enabled with the flow control command are not affected by latency.

Table A-14 1-Gbps FC and FICON Latency Values for 4-Port 1-Gbps/2-Gbps Aggregation Cards 

Traffic Mix on Transmitting Node
Maximum Added End-to-End Latency
No GE
1518-Byte GE Packets
4470-Byte GE Packets
10,232-Byte GE Packets

FC/FICON only on the 2.5-Gbps aggregated signal carried over a 2.5-Gbps ITU trunk card (single port in the portgroup)

12.2 micro
seconds

 

 

 

FC/FICON only on the 2.5-Gbps aggregated signal carried over a 2.5-Gbps ITU trunk card (two ports in the portgroup)

12.7 micro
seconds

     

FC/FICON only on a 2.5-Gbps aggregated signal carried over a 10-Gbps ITU trunk card (single port in the portgroup)

11.6 micro
seconds

 

 

 

FC/FICON only on a 2.5-Gbps aggregated signal carried over a 10-Gbps ITU trunk card (two ports in the portgroup)

12.1 micro
seconds

     

FC/FICON only on a 2.5-Gbps aggregated signal mixed with GE on the same 10-Gbps ITU trunk card (single port in portgroup)

 

12.8 micro
seconds

15.2 micro
seconds

23.9 micro
seconds

FC/FICON only on a 2.5-Gbps aggregated signal mixed with GE on the same 10-Gbps ITU trunk card (two ports in portgroup)

 

13.5 micro
seconds

16.8 micro
seconds

26.2 micro
seconds


Table A-15 2-Gbps FC and FICON Latency Values for 4-Port 1-Gbps/2-Gbps Aggregation Cards 

Traffic Mix on Transmitting Node
Maximum Added End-to-End Latency
No GE
1518-Byte GE Packets
4470-Byte GE Packets
10,232-Byte GE Packets

FC/FICON only on the 2.5-Gbps aggregated signal carried over a 2.5-Gbps ITU trunk card

10.6 µs

 

 

 

FC/FICON only on a 2.5-Gbps aggregated signal carried over a 10-Gbps ITU trunk card

9.9 µs

 

 

 

FC/FICON only on a 2.5-Gbps aggregated signal mixed with GE on the same 10-Gbps ITU trunk card

 

12.1 µs

15.4 µs

25.1 µs


8-Port FC/GE Aggregation Card

The optical power characteristics of the SFP (small form-factor pluggable) optics for the 8-port Fibre Channel/Gigabit Ethernet aggregation cards are shown in Table A-16. The optical power characteristics of the supported SFP optics are listed in the SFP Specifications section. Only use Cisco-certified SFP optics for the 8-port FC/GE aggregation cards. If the specifications of the client equipment interfaces do not fall within these ranges, attenuators or amplifiers might be required.


Note The optical specifications described in this section are only for the individual components and should not be used to characterize the entire network performance.


Table A-16 SFPs Supported by the 8-port FC/GE Aggregation Card 

SFP Part Number
Description

15500-XVRA-02C1

Gigabit Ethernet1 , Fibre Channel (1 Gbps)2 , FICON (1 Gbps)

15500-XVRA-03B1

Gigabit Ethernet3 , Fibre Channel (1 Gbps)4 , FICON (1 Gbps), ISC-3 links compatibility mode

15500-XVRA-11B1

Mid-band variable rate 200 Mbps to 1.25 Gbps

15500-XVRA-12B1

High-band variable rate 1.062 Gbps to 2.488 Gbps

1 1000BASE-SX

2 FC-0-100-M5-SN-S and FC-0-100-M6-SN-S standards

3 1000BASE-LX

4 FC-0-100-SM-LC-S standard



Note The MTU (maximum transmission unit) for the 8-port FC/GE aggregation card is 10,232 bytes.


The 8-port FC/GE aggregation card adds latency to FC traffic. Table A-17 shows the FC latency values for different configurations of the 8-port FC/GE aggregation card.

Table A-17 FC and FICON Latency Values for 8-Port FC/GE Aggregation Cards 

Traffic Mix on Transmitting Node
Maximum Added End-to-End Latency1 (Time and Distance)
No GE2
1518-Byte GE Packets
4470-Byte GE Packets
10,232-Byte GE Packets

FC3 /FICON4 only on the 2.5-Gbps aggregated signal carried over a 2.5-Gbps ITU5 trunk card

18.8 µs (3.8 km)

 

 

 

FC/FICON only on a 2.5-Gbps aggregated signal carried over a 10-Gbps ITU trunk card

19.9 µs (4.0 km)

 

 

 

FC/FICON only on a 2.5-Gbps aggregated signal mixed with GE on the same 10-Gbps ITU trunk card

 

22.2 µs (4.4 km)

24.8 µs (5.0 km)

36.3 µs (7.3 km)

FC/FICON and GE on the same 2.5-Gbps aggregated signal carried over a 2.5-Gbps ITU trunk card

 

27.9 µs (5.6 km)

47.1 µs (9.4 km)

83.6 µs (16.7 km)

FC/FICON and GE on the same 2.5-Gbps aggregated signal carried over a 10-Gbps ITU trunk card

 

39.2 µs (7.8 km)

77.1 µs (15.4 km)

151.1 µs (30.2 km)

1 The latency values are based on configuration of correct transmit buffer sizes as described in the Cisco ONS 15530 Configuration Guide.

2 GE = Gigabit Ethernet

3 FC = Fibre Channel

4 FICON = Fiber Connection

5 ITU = International Telecommunication Union


8-Port Multi-Service Muxponder Specifications

Table A-18 lists the 8-port multi-service muxponder receiver and transmitter specifications. Optical loss because of splitter modules and connectors should be included in the optical budget calculation.


Note The optical specifications described in this section are only for the individual components and should not be used to characterize the entire network performance.


Table A-18 8-Port Multi-Service Muxponder ITU Trunk Specifications 

Description
Specification

Fiber type

G.652 (SMF-25)

Connector

MU-PC

Receiver sensitivity
OSNR1 , 2
Dispersion

-26 dBm

20 dB

±1000 ps/nm3

-24 dBm

21 dB

1000 to 2100 ps/nm

-23 dBm

2 dB

2100 to 3200 ps/nm

Receiver
Minimum
Maximum

Overload

 

-8 dBm

Wavelength

1260 nm

1580 nm

Transmitter
Minimum
Maximum

Transmitter power

5 dBm

10 dBm

1 OSNR = optical signal-to-noise ratio.

2 Add the proper network-level penalty to the OSNR and/or receive power based on your actual network topology characteristics, such as dispersion.

3 ps/nm = picoseconds per nanometer.


 

The SFPs supported on the 8-port multi-service muxponder are shown in Table A-19. The optical power characteristics and other specifications of the supported SFPs are listed in the "SFP Specifications" section. Only use Cisco-certified SFPs for the 8-port multi-service muxponder.


Note The optical specifications described in this section are only for the individual components and should not be used to characterize the entire network performance.


Table A-19 SFPs Supported by the 8-Port Multi-Service Muxponder 

Part Number
Protocols or Clock Rate Range Supported

15500-XVRA-10A2

Low band 8 Mbps to 200 Mbps

15500-XVRA-10B2

Low band 8 Mbps to 200 Mbps

15500-XVRA-11A2

Mid-band 200 Mbps to 622 Mbps

15500-XVRA-11B2

Mid-band 200 Mbps to 1.25 Gbps

15500-XVRA-12B1

High-band 1.062 Gbps to 2.488 Gbps

15500-XVRA-08D1

T11 1.544 Mbps

15500-XVRA-09D1

E1 2.044 Mbps

15500-XVRA-10E1

SDI and DVB-ASI video2 , 3

15500-XVRA-11D1

GE 1.25 Gbps, FE 1.25 Mbps4

ONS-SE-GEFC-SX

Fibre Channel (2.125 Gbps), Fibre Channel (1 Gbps), Gigabit Ethernet

1 DSX-1 interface

2 In a normal operating environment, the maximum digital video application connection length using a Belden 1694A cable is 200 m (218 yd). If the chassis ambient operating temperature is above 45°C (113° F) and ports 0 and 1 are used for video applications with this SFP, the maximum cable connection length supported may be less than the specified 200 m (218 yd), depending on the operating environment.

3 DVB-ASI = Digital Video Broadcast Asynchronous Serial Interface.

4 To ensure proper operation of the 15500-XVRA-11D1 SFP, the ambient operating temperature should not exceed 45°C (113°F).


Table A-20 lists the typical latencies for the 8-port multi-service muxponder.

Table A-20 Latency Values for the 8-Port Multi-Service Muxponder

Protocol
Unidirectional End-to-End Latency with 0 km Fiber
Typical
Maximum

ESCON

10 µs

13 µs

Fibre Channel

4 µs

6 µs

Gigabit Ethernet optical

6 µs

8 µs

Gigabit Ethernet copper

9 µs

11 µs

Fast Ethernet optical

14 µs

17 µs

Fast Ethernet copper

18 µs

20 µs

SDI

17 µs

20 µs

DVB-ASI

9 µs

11 µs


SDI Jitter Performance

SDI video signal is compliant to the ANSI/SMPTE 259M-1997 standard. Table A-21 lists the SDI jitter performance values for the 8-port multi-service muxponder.

Table A-21 SDI Jitter Performance Values for the 8-Port Multi-Service Muxponder 

Hp Filter
10 Hz
1 kHz
10 kHz
100 kHz

Jitter Generation (p-p)

0.5 UI1

0.06 UI

0.06 UI

0.06 UI

UI / Time

1.85 ns

220 ps

220 ps

220 ps

1 Maximum jitter generation is below SMPTE 259 M specification of 0.2 UI (0.74 ns) with the exception of low-frequency timing jitter. However, a purely digital system will operate correctly with significant amounts of low-frequency jitter as also indicated in Annex B of SMPTE 259M of the Timing Jitter Specification.


If your configuration uses an on-board system clock for trunk multiplexing, the client OC-3 wander generation may exceed the GR-253 specification of less than 60 ns MTIE (maximum time interval error) on greater than 10-second intervals and 20 ns MTIE on less than 1-second intervals. Because the MTIE can reach 100 ns across all observation intervals with this configuration, we do not recommend using the OC-3 transport for deriving the network clock. Other applications operate normally. If needed, the trunk multiplex clock can be configured to use one of the client OC-3 receive clocks. In this configuration, the OC-3 wander generation is fully compliant to GR-253 specification.

2.5-Gbps ITU Trunk Card Specifications

Table A-22 lists the 2.5-Gbps ITU trunk card receiver and transmitter specifications. Optical loss due to splitter modules and connectors should be included in the optical budget calculation.


Note The optical specifications described in this section are only for the individual components and should not be used to characterize the entire network performance.


Table A-22 2.5-Gbps ITU Trunk Card Optical Specifications 

Description
Specification

Fiber type

SM1 9 micron

Connector

MU

Receiver
Minimum
Maximum

OSNR 2 , 3

19 dB

 

Receive sensitivity 3

-28 dBm

 

Receive overload

 

-8 dBm

Input wavelength

1260 nm

1580 nm

Transmitter
Minimum
Maximum

Transmitter power

5 dBm

10 dBm

Dispersion tolerance

 

3200 ps/nm4

1 SM = single mode.

2 OSNR = optical signal-to-noise ratio.

3 Add the proper network-level penalty to the OSNR and/or receive power based on your actual network topology characteristics, such as dispersion.

4 ps/nm = picoseconds per nanometer.


 

10-Gbps ITU Tunable and Non tunable Trunk Card Specifications

Table A-23 lists the specifications for tunable and non tunable 10-Gbps ITU trunk card for the client side lasers. Optical loss due to splitter modules and connectors should be included in the optical budget calculation.


Note The optical specifications described in this section are only for the individual components and should not be used to characterize the entire network performance.


Table A-23 10-Gbps ITU Tunable and Non tunable Trunk Card Specifications  

Description
Specification

Fiber type

ITU-T G.652

Connector

MU

Receiver
Minimum
Maximum

OSNR1 , 2

26 dB

 

Receive sensitivity 2

-22 dBm

 

Receive overload

 

-8 dBm

Input wavelength

1430 nm

1580 nm

Transmitter
Minimum
Maximum

Output power

1 dBm

6 dBm

Dispersion tolerance

 

± 1000 ps/nm3

1 OSNR = optical signal-to-ratio.

2 Add the proper network level penalty to the OSNR and/or receive power based on your actual network topology characteristics, such as dispersion.

3 ps/nm = picosecond per nanometer.


10-Gbps Uplink Card

Table A-24 lists the specifications for the 10-Gbps uplink cards supported by the Cisco ONS 15530 in the transmit and receive directions.


Note The optical specifications described in this section are only for the individual components and should not be used to characterize the entire network performance.


Table A-24 10-Gbps Uplink Card Specifications  

Description
Specification

Fiber type

SM1 1310 nm

Connector

SC

Dimensions

10.4 x 1.105 x 8.797 in.
(264.2 x 28.1 x 223.4 mm)

Bit rate

10 GE LAN-PHY

Receiver
Minimum
Maximum

Receive sensitivity

-13.23 dBm

 

Receive overload

 

0.5 dBm

Stressed receive sensitivity

 

-10.3 dBm

Transmitter
Minimum
Maximum

Transmit power

-5.2 dBm

0.5 dBm

Wavelength range

1260 nm

1355 nm

1 SM = single mode


SFP Specifications

Table A-25 lists the specifications for the Cisco ONS 15530 fixed rate SFP optics.


Note Only use Cisco-certified SFP optics for the 8-port FC/GE and ESCON aggregation cards.


Table A-25 Fixed Rate SFP Optics Specifications 

Description
Specification
Part number
15500-XVRA-01A2

ESCON, OC-3/STM-1 MM

Dimensions (H x W x D)

0.486 x 0.522 x 2.24 in. (1.23 x 1325.9 x 5.69 cm)

Data rate

155 Mbps, 200 Mbps

Wavelength

1310 nm

Fiber type

MM, 50 µm, 62.5 µm

Connector type

MT-RJ

Cladding diameter

125 µm

Receiver
Minimum
Maximum

Receive sensitivity

-33 dBm

-14 dBm

Input wavelength

1280 nm

1380 nm

Transmitter
Minimum
Maximum

Transmitter power

-19.5 dBm

-15 dBm

Output wavelength

1280 nm

1380 nm

Part number
15500-XVRA-02C1

Gigabit Ethernet, Fibre Channel (1 Gbps), and FICON (1 Gbps) MM, ISC-1 (1-Gbps)

Dimensions

0.486 x 0.522 x 2.24 in (1.23 x 1325.9 x 5.69 cm)

Data rate

1.0625 Gbps, 1.25 Gbps

Wavelength

850 nm

 

Fiber type

MM, 50 micron, 62.5 micron

Connector type

LC

Cladding diameter

125 µm

 
Minimum
Maximum

Receive sensitivity

-18 dBm

 

Stressed receive sensitivity

 

-13.5 dBm

Input wavelength

770 nm

860 nm

Transmitter power

-9.5 dBm

-4 dBm

Output wavelength

830 nm

860 nm

Part number
15500-XVRA-03B1

GE, FC (1 Gbps), and FICON (1 Gbps) SM

Dimensions

0.486 x 0.522 x 2.24 in. (1.23 x 1325.9 x 5.69 cm)

Data rate

1.0625 Gbps, 1.25 Gbps

Wavelength

1310 nm

Fiber type

MM, 50 µm, 62.5 µm

Connector type

LC

Cladding diameter

125 µm

Receiver
Minimum
Maximum

Receive sensitivity

-18 dBm

 

Stressed receive sensitivity

-13.5 dBm

 

Input wavelength

770 nm

860 nm

Transmitter
Minimum
Maximum

Transmitter power

-9.5 dBm

-4 dBm

Part number
15500-XVRA-03B1

Gigabit Ethernet, Fibre Channel (1 Gbps), FICON (1 Gbps) SM

Dimensions

0.486 x 0.522 x 2.24 in.
(1.23 x 1325.9 x 5.69 cm)

Data rate

1.0625 Gbps, 1.25 Gbps

Wavelength

1310 nm

Fiber type

SM, 9/125 µm

Connector type

LC

Receiver
Minimum
Maximum

Input power

-20.5 dBm

-3 dBm

Input wavelength

1270 nm

1600 nm

Transmitter
Minimum
Maximum

Transmitter power

-9.5 dBm

-3 dBm

Output wavelength

1275 nm

1350 nm

Part number
15500-XVRA-03B2

Fibre Channel (1 Gbps and 2 Gbps) and FICON (1 Gbps and 2 Gbps) SM

Dimensions

0.486 x 0.522 x 2.24 in.
(1.23 x 1325.9 x 5.69 cm)

Data rate

1.0625 Gbps, 2.125 Gbps

Wavelength

1310 nm

Fiber type

SM, 9/125 µm

Connector type

LC

Receiver
Minimum
Maximum

Receive sensitivity

-20.5 dBm

 

Input wavelength

1270 nm

1600 nm

Transmitter
Minimum
Maximum

Transmitter power

-9.5 dBm

-3 dBm

Output wavelength

1275 nm

1350 nm


Table A-26 lists the specifications for the Cisco ONS 15530 variable rate SFP optics.


Note Only use Cisco-certified SFP optics for the 4-port 1-Gbps/2-Gbps FC aggregation cards, 8-port FC/GE aggregation cards, 8-port multi-service muxponders, and ESCON aggregation cards.


Table A-26 Variable Rate SFP Optics Specifications 

Description
Specification
Part number
15500-XVRA-10A1

Supported protocol encapsulations

ESCON (MM)

Dimensions

0.486 x 0.522 x 2.24 in. (1.23 x 1325.9 x 5.69 cm)

Data rate

8 to 200 Mbps

Wavelength

1310 nm

Fiber type

MM 50/125 µm
MM 62.5/125 µm

Connector type

LC

Receiver
Minimum
Maximum

Receive sensitivity @10-12 BER1

-32 dBm

 

Receive sensitivity @10-15 BER

-29 dBm

 

Receive overload @10-12  BER

 

-14 dBm

Input wavelength

1100 nm

1600 nm

Transmitter
Minimum
Maximum

Transmitter power

-19 dBm

-14 dBm

Output wavelength

1280 nm

1380 nm

Part number
15500-XVRA-10A2

Supported protocol encapsulations

ESCON (MM)

Dimensions

0.486 x 0.522 x 2.24 in. (1.23 x 1325.9 x 5.69 cm)

Data rate

8 to 200 Mbps

Wavelength

1310 nm

Fiber type

MM 50/125 µm
MM 62.5/125 µm

Connector type

LC

Receiver
Minimum
Maximum

Receive sensitivity @10-12 BER2

-32 dBm

 

Receive sensitivity @10-15 BER

-29 dBm

 

Receive overload @10-12  BER

 

-14 dBm

Input wavelength

1100 nm

1600 nm

Transmitter
Minimum
Maximum

Transmitter power

-19 dBm

-14 dBm

Output wavelength

1280 nm

1380 nm

Part number
15500-XVRA-10B1

Supported protocol encapsulations

ESCON (SM)

Dimensions

0.486 x 0.522 x 2.24 in. (1.23 x 1325.9 x 5.69 cm)

Data rate range

8 Mbps to 200 Mbps

Wavelength

1310 nm

Fiber type

SM, 9/125 µm

Connector type

LC

Receiver
Minimum
Maximum

Receive sensitivity @10-12 BER

-32 dBm

 

Receive overload @10-12  BER

 

-3 dBm

Input wavelength

1100 nm

1600 nm

Transmitter
Minimum
Maximum

Transmitter power

-8 dBm

-4 dBm

Output wavelength

1260 nm

1360 nm

Part number
15500-XVRA-10B2

Supported protocol encapsulations

ESCON (SM)

Dimensions

0.486 x 0.522 x 2.24 in. (1.23 x 1325.9 x 5.69 cm)

Data rate range

8 Mbps to 200 Mbps

Wavelength

1310 nm

Fiber type

SM, 9/125 µm

Connector type

LC

Receiver
Minimum
Maximum

Receive sensitivity @10-12 BER

-32 dBm

 

Receive overload @10-12  BER

 

-3 dBm

Input wavelength

1100 nm

1600 nm

Transmitter
Minimum
Maximum

Transmitter power

-8 dBm

-4 dBm

Output wavelength

1260 nm

1360 nm

Part number
15500-XVRA-11A1

Supported protocol encapsulations

ESCON, OC-12/STM-4

Dimensions

0.486 x 0.522 x 2.24 in. (1.23 x 1325.9 x 5.69 cm)

Data rate range

200 Mbps to 622 Mbps

Wavelength

1310 nm

Fiber type

MM 62.5/125 µm

Connector type

LC

Receiver
Minimum
Maximum

Receive sensitivity @10-10 BER

-26 dBm

 

Receive sensitivity @10-12 BER

-25 dBm

 

Maximum receive power @10-10  BER

 

-14

Input wavelength

1100 nm

1600 nm

Transmitter
Minimum
Maximum

Transmitter power

-20 dBm

-14 dBm

Output wavelength

1270 nm

1380 nm

Part number
15500-XVRA-11A2

Supported protocol encapsulations

ESCON, OC-12/STM-4

Dimensions

0.486 x 0.522 x 2.24 in. (1.23 x 1325.9 x 5.69 cm)

Data rate range

200 Mbps to 622 Mbps

Wavelength

1310 nm

Fiber type

MM 62.5/125 µm

Connector type

LC

Receiver
Minimum
Maximum

Receive sensitivity @10-10 BER

-26 dBm

 

Receive sensitivity @10-12 BER

-25 dBm

 

Maximum receive power @10-10  BER

 

-14

Input wavelength

1100 nm

1600 nm

Transmitter
Minimum
Maximum

Transmitter power

-20 dBm

-14 dBm

Output wavelength

1270 nm

1380 nm

Part number
15500-XVRA-11B1

Supported protocol encapsulations

FC, FICON, GE, ISC-1

Dimensions

0.486 x 0.522 x 2.24 in. (1.23 x 1325.9 x 5.69 cm)

Data rate range

200 Mbps to 1.25 Gbps

Wavelength

1310 nm

Fiber type

SM, 9/125 µm

Connector type

LC

Receiver
Minimum
Maximum

Receive sensitivity @10-12 BER

-19 dBm

 

Maximum receive power @10-12 BER

 

-3 dBm

Input wavelength

1100 nm

1600 nm

Transmitter
Minimum
Maximum

Transmitter power

-11 dBm

-3 dBm

Output wavelength

1285 nm

1345 nm

Part number
15500-XVRA-11B2

Supported protocol encapsulations

FC, FICON, GE, ISC-1

Dimensions

0.486 x 0.522 x 2.24 in. (1.23 x 1325.9 x 5.69 cm)

Data rate range

200 Mbps to 1.25 Gbps

Wavelength

1310 nm

Fiber type

SM, 9/125 µm

Connector type

LC

Receiver
Minimum
Maximum

Receive sensitivity @10-12 BER

-19 dBm

 

Maximum receive power @10-12 BER

 

-3 dBm

Input wavelength

1100 nm

1600 nm

Transmitter
Minimum
Maximum

Transmitter power

-11 dBm

-3 dBm

Output wavelength

1285 nm

1345 nm

Part number
15500-XVRA-12B1

Supported protocol encapsulations

FC, FICON, GE, ISC-1, ISC-3

Dimensions

0.486 x 0.522 x 2.24 in (1.23 x 1325.9 x 5.69 cm)

Data rate range

1.062 Mbps to 2.488 Gbps

Wavelength

1310 nm

Fiber type

SM, 9/125 µm

Connector type

LC

Receiver
Minimum
Maximum

Receive sensitivity @10-10 BER

-18 dBm

 

Maximum receive power @10-10  BER

 

-3 dBm

Input wavelength

1100 nm

1600 nm

Transmitter
Minimum
Maximum

Transmitter power

-10 dBm

-3 dBm

Output wavelength

1266 nm

1360 nm

Part number
15454-SFP-GEFC-SX

Supported protocol encapsulations

Fibre Channel (2.125 Gbps), Fibre Channel (1 Gbps), Gigabit Ethernet

Dimensions

0.486 x 0.522 x 2.24 in (1.23 x 1325.9 x 5.69 cm)

Data rate range

1.062 Gbps, 1.25 Gbps, 2.125 Gbps

Wavelength

830 to 860 nm

Fiber type

MM 50/125 µm, MM 62.5/125 µm

Connector type

Duplex LC

Receiver

Receive sensitivity @2.125 Gbps

-18 mW

Receive sensitivity @1.25 Gbps

-20 dBm

Receive sensitivity @1.06 Gbps

-20 mW

Maximum receive power

0 dBm

Receiver
Minimum
Maximum

Input wavelength

770 nm

860 nm

Transmitter
Minimum
Maximum

Transmitter power

-9 dBm

-3.5 dBm

Output wavelength

830 nm

860 nm

1 BER = bit error rate

2 BER = bit error rate


Table A-27 lists the specifications for the copper SFPs supported on the 8-port multi-service muxponder.

Table A-27 Copper SFP Specifications 

Description
Specification
Part number
15500-XVRA-08D1

T1 1.544 Mbps

Dimensions

0.486 x 0.522 x 2.24 in. (1.23 x 1325.9 x 5.69 cm)

Data rate

1.544 Mbps

Fiber type

Copper T1

Connector type

RJ-45

CAT5K cable

600 ft (182.9 m)

Part number
15500-XVRA-09D1

E1 2.044 Mbps

Dimensions

0.486 x 0.522 x 2.24 in. (1.23 x 1325.9 x 5.69 cm)

Data rate

2.044 Mbps

Fiber type

Copper E1

Connector type

RJ-45

CAT5K cable

450 ft (137 m)

Part number
15500-XVRA-10E1

SDI and DVB-ASI Video 270Mbps

Dimensions

0.486 x 0.522 x 2.24 in. (1.23 x 1325.9 x 5.69 cm)

Data rate

270Mbps

Fiber type

Copper digital video

Connector type

SMB/BNC

Balden 1694A cable

656 ft (200 m)

Part number
15500-XVRA-11D1

GE 1.25 Gbps, FE 1.25 Mbps

Dimensions

0.486 x 0.522 x 2.24 in. (1.23 x 1325.9 x 5.69 cm)

Data rate

GE 1.25 Gbps, FE 1.25 Mbps

Fiber type

Copper GE/FE

Connector type

RJ-45

CAT5K cable

Cu GE and FE is 100 m (328.08 ft)



hometocprevnextglossaryfeedbacksearchhelp

Posted: Wed Jul 5 19:20:55 PDT 2006
All contents are Copyright © 1992--2006 Cisco Systems, Inc. All rights reserved.
Important Notices and Privacy Statement.