Table Of Contents
PB-OE and WB-VOA Module Specifications
Transponder Line Card Specifications
ESCON Aggregation Card Specifications
4-Port 1-Gbps/2-Gbps FC Aggregation Card
8-Port Multi-Service Muxponder Specifications
2.5-Gbps ITU Trunk Card Specifications
10-Gbps ITU Tunable and Non tunable Trunk Card Specifications
Specifications
This appendix describes the specifications for the chassis, line cards, and the carrier motherboard and modules used in the Cisco ONS 15530 system. This appendix includes the following sections:
• Channel to Wavelength Mapping
• PB-OE and WB-VOA Module Specifications
• Transponder Line Card Specifications
• ESCON Aggregation Card Specifications
• 4-Port 1-Gbps/2-Gbps FC Aggregation Card
• 8-Port FC/GE Aggregation Card
• 8-Port Multi-Service Muxponder Specifications
• 2.5-Gbps ITU Trunk Card Specifications
• 10-Gbps ITU Tunable and Non tunable Trunk Card Specifications
Note Cisco recommends you to use the Cisco MetroPlanner tool to design your DWDM networks. For more information about optical power budgets and network planning, refer to the Cisco ONS 15530 Planning Guide and the Cisco MetroPlanner DWDM Operations Guide.
Chassis Specifications
Table A-1 lists the specifications for the Cisco ONS 15530.
Table A-1 Cisco ONS 15530 Specifications
Description Specification EnvironmentalTemperature, ambient operating
32 to 104°F (0 to +40°C)
Humidity (RH1 ), ambient (non- condensing) operating
5 to 95%
Altitude, operating and non-operating
Minimum -197 ft (-60 m)
Maximum 6500 ft (2000 m) Cisco ONS 15530 CHAS-EDimensions (H x W x D)
14.4 x 17.3 x 10.1 in.
(365.9 x 439.4 x 256.5 mm)Weight
Empty chassis: 27.5 lbs (12.25 kg)
Fully loaded: 71 lbs (32.21 kg) Cisco ONS 15530 CHAS-NDimensions (H x W x D)
15.7 x 17.3 x 10.1 in.
(398.8 x 439.4 x 256.5 mm)Weight
Empty chassis: 27.0 lbs (12.25 kg)
Fully loaded: 71 lbs (32.21 kg) AC-Input PowerAC-input voltage
100 to 240 VAC (nominal)
85 to 264 VAC (full range)Power consumption maximum
600W
Heat dissipation
2048 BTU/hr
DC-Input PowerDC-input voltage
-48 to -60 VDC (nominal)
-40.5 to -72 VDC (full range)Power consumption maximum
600W (fully configured system)
Heat dissipation
2048 BTU/hr
1 RH = relative humidity
Channel to Wavelength Mapping
Table A-2 lists the channels, wavelengths, and frequencies for each band.
Table A-2 Channel to Wavelength Mapping
Cisco ONS 15530
Band Cisco ONS 15530
Channel ITU1 Channel ITU Wavelength2 ITU Frequency3OSC4
19
1562.23
191.9000
A
1
21
1560.61
192.100
2
22
1559.79
192.200
3
23
1558.98
192.300
4
24
1558.17
192.400
B
5
26
1556.55
192.600
6
27
1555.75
192.700
7
28
1554.94
192.800
8
29
1554.13
192.900
C
9
31
1552.52
193.100
10
32
1551.72
193.200
11
33
1550.92
193.300
12
34
1550.12
193.400
D
13
36
1548.51
193.600
14
37
1547.72
193.700
15
38
1546.92
193.800
16
39
1546.12
193.900
E
17
41
1544.53
194.100
18
42
1543.73
194.200
19
43
1542.94
194.300
20
44
1542.14
194.400
F
21
46
1540.56
194.600
22
47
1539.77
194.700
23
48
1538.98
194.800
24
49
1538.19
194.900
G
25
51
1536.61
195.100
26
52
1535.82
195.200
27
53
1535.04
195.300
28
54
1534.25
195.400
H
29
56
1532.68
195.600
30
57
1531.90
195.700
31
58
1531.12
195.800
32
59
1530.33
195.900
1 ITU = International Telecommunication Union
2 Wavelengths in vacuum in nm
3 Frequency in THz, 100 GHz grid
4 OSC = optical supervisory channel
OADM Module Specifications
Table A-3 shows the maximum optical link loss for the data channels between the 4-channel OADM modules and the line cards, and between the pass-through add and drop connectors on the OADM modules.
Note The optical specifications described in this section are only for the individual components and should not be used to characterize the entire network performance.
PSM Specifications
Table A-4 and Table A-5 lists the PSM (protection switch module) card and optical specifications for the Cisco ONS 15530.
Note The optical specifications described in this section are only for the individual components and should not be used to characterize the entire network performance.
Table A-4 PSM Card Specifications
Description SpecificationDimensions
3.7 x 9 in. (9.4 x 22.9 cm)
Weight
3.5 lbs (1.59 kg)
Connector
MU
Receive overload
17 dBm
Note The accuracy of the power detector is ±1.9 dB over the entire C band and temperature range.
OSC Module Specifications
Table A-6 lists the OSC module receiver and transmitter specifications.
Note The optical specifications described in this section are only for the individual components and should not be used to characterize the entire network performance.
Table A-6 OSC Module Specifications
Description SpecificationFiber type
SM1 9 micron
Connector
MU
Output wavelength
1562.23 ITU channel
Receiver Minimum MaximumReceive sensitivity
-19 dBm
Receive overload
-1.5 dBm
Input wavelength
1249 nm
1600 nm
Transmitter Minimum MaximumTransmitter power
5 dBm
10 dBm
Dispersion tolerance
3200 ps/nm
1 SM = single mode.
PB-OE and WB-VOA Module Specifications
Table A-7 contains specifications for the Cisco ONS 15530 single-band PB-OE module. Table A-8 contains specifications for the Cisco ONS 15530 single and dual WB-VOA modules.
Note The optical specifications described in this section are only for the individual components and should not be used to characterize the entire network performance.
Transponder Line Card Specifications
Table A-9 lists the transponder line card receiver and transmitter specifications for the client side lasers.
Note The optical specifications described in this section are only for the individual components and should not be used to characterize the entire network performance.
Table A-9 Client Side Optical Specifications
Description SpecificationFiber type
SM1 9 micron
Connector
SC
Receiver SM Minimum SM Maximum MM2 Minimum MM MaximumReceive sensitivity
-19 dBm
-25 dBm
Receive overload
-1.5 dBm
-8 dBm
Input wavelength
1249 to 1600 nm3
1249 to 1600 nm
Optical reflectance
-27 dB4
Receiver fiber pigtail
MM 50 micron
MM 62.5 micron
Transmitter SM Minimum SM Maximum MM5 Minimum MM MaximumOutput wavelength
1260 to 1360 nm
1260 to 1360 nm
Transmitter power
-5 dBm
0 dBm
-5 dBm
0 dBm
1 SM = single mode
2 MM = multimode
3 nm = nanometers
4 dB = decibels
5 MM = multimode
Table A-10 lists the transponder line card receiver and transmitter specifications for the trunk side lasers.
Note Optical loss due to splitter modules and connectors should be included in the optical budget calculation.
Table A-10 Trunk Side Optical Specifications
Description SpecificationFiber type
SM 9 micron
Connector
MU
Receiver Minimum Maximum19 dB
Receive sensitivity 2
-28 dBm
Receive overload
-8 dBm
Input wavelength
1260 nm
1580 nm
Transmitter Minimum MaximumTransmitter power
5 dBm
10 dBm
Dispersion tolerance
3200 ps/nm3
1 OSNR = optical signal-to-noise ratio.
2 Add the proper network-level penalty to the OSNR and/or receive power based on your actual network topology characteristics, such as dispersion.
3 ps/nm = picoseconds per nanometer.
ESCON Aggregation Card Specifications
Table A-11 lists SFP optics supported by the 10-port ESCON aggregation card. The optical power characteristics of the supported SFP optics are listed in the SFP Specifications section.
Note The optical specifications described in this section are only for the individual components and should not be used to characterize the entire network performance.
Table A-12 lists the maximum added end-to-end latency is from the ESCON aggregation cards aggregating and separating the client signals.
Note The ESCON latency values have been determined by simulation and are approximate.
Table A-12 Latency for ESCON Aggregation Cards
Traffic Mix on Transmitting Node Maximum Added End-to-End Latency1 No GE 1518-Byte GE Packets 4470-Byte GE Packets 10,230-Byte GE PacketsESCON only
8.5 µs
ESCON and FC/FICON on the same 10-Gbps ITU trunk card
8.5 µs
ESCON and GE only on the same 10-Gbps ITU trunk card
10 µs
12.5 µs
17 µs
1 The latency values are based on configuration of correct transmit buffer sizes as described in the Cisco ONS 15530 Configuration Guide.
4-Port 1-Gbps/2-Gbps FC Aggregation Card
The 4-port 1-Gbps/2-Gbps FC aggregation cards support the SFPs listed in Table A-13. The optical power characteristics of the supported SFPs are listed in the SFP Specifications section. Only use Cisco-certified SFPs for the 4-port 1-Gbps/2-Gbps FC aggregation cards. If the specifications of the client equipment interfaces do not fall within these ranges, attenuators or amplifiers might be required.
Note The optical specifications described in this section are only for the individual components and should not be used to characterize the entire network performance.
Table A-13 SFPs Supported by the 4-port 1-Gbps/2-Gbps FC Aggregation Card
Part Number Protocols or Clock Rate Range Supported15500-XVRA-02C1
Gigabit Ethernet1 , Fibre Channel (1 Gbps)2 , FICON (1 Gbps)
15500-XVRA-03B1
Gigabit Ethernet3 , Fibre Channel (1 Gbps)4 , FICON (1 Gbps), ISC-3 links compatibility mode
15500-XVRA-03B2
Fibre Channel (1 Gbps and 2 Gbps), FICON (1 Gbps and 2 Gbps)
15500-XVRA-11B1
Mid-band variable rate 200 Mbps to 1.25 Gbps
15500-XVRA-12B1
High-band variable rate 1.062 Gbps to 2.488 Gbps
15454-SFP-GEFC-SX
Fibre Channel (2 Gbps), Fibre Channel (1 Gbps), Gigabit Ethernet, FICON (1 Gbps and 2 Gbps)
1 1000BASE-SX
2 FC-0-100-M5-SN-S and FC-0-100-M6-SN-S standards
3 1000BASE-LX
4 FC-0-100-SM-LC-S standard
Table A-14 and Table A-15 show the latency value for the various configurations on the transmitting node.
FC and FICON traffic on interfaces with buffer credits enabled with the flow control command are not affected by latency.
8-Port FC/GE Aggregation Card
The optical power characteristics of the SFP (small form-factor pluggable) optics for the 8-port Fibre Channel/Gigabit Ethernet aggregation cards are shown in Table A-16. The optical power characteristics of the supported SFP optics are listed in the SFP Specifications section. Only use Cisco-certified SFP optics for the 8-port FC/GE aggregation cards. If the specifications of the client equipment interfaces do not fall within these ranges, attenuators or amplifiers might be required.
Note The optical specifications described in this section are only for the individual components and should not be used to characterize the entire network performance.
Table A-16 SFPs Supported by the 8-port FC/GE Aggregation Card
SFP Part Number Description15500-XVRA-02C1
Gigabit Ethernet1 , Fibre Channel (1 Gbps)2 , FICON (1 Gbps)
15500-XVRA-03B1
Gigabit Ethernet3 , Fibre Channel (1 Gbps)4 , FICON (1 Gbps), ISC-3 links compatibility mode
15500-XVRA-11B1
Mid-band variable rate 200 Mbps to 1.25 Gbps
15500-XVRA-12B1
High-band variable rate 1.062 Gbps to 2.488 Gbps
1 1000BASE-SX
2 FC-0-100-M5-SN-S and FC-0-100-M6-SN-S standards
3 1000BASE-LX
4 FC-0-100-SM-LC-S standard
Note The MTU (maximum transmission unit) for the 8-port FC/GE aggregation card is 10,232 bytes.
The 8-port FC/GE aggregation card adds latency to FC traffic. Table A-17 shows the FC latency values for different configurations of the 8-port FC/GE aggregation card.
Table A-17 FC and FICON Latency Values for 8-Port FC/GE Aggregation Cards
Traffic Mix on Transmitting Node Maximum Added End-to-End Latency1 (Time and Distance) No GE2 1518-Byte GE Packets 4470-Byte GE Packets 10,232-Byte GE PacketsFC3 /FICON4 only on the 2.5-Gbps aggregated signal carried over a 2.5-Gbps ITU5 trunk card
18.8 µs (3.8 km)
FC/FICON only on a 2.5-Gbps aggregated signal carried over a 10-Gbps ITU trunk card
19.9 µs (4.0 km)
FC/FICON only on a 2.5-Gbps aggregated signal mixed with GE on the same 10-Gbps ITU trunk card
22.2 µs (4.4 km)
24.8 µs (5.0 km)
36.3 µs (7.3 km)
FC/FICON and GE on the same 2.5-Gbps aggregated signal carried over a 2.5-Gbps ITU trunk card
27.9 µs (5.6 km)
47.1 µs (9.4 km)
83.6 µs (16.7 km)
FC/FICON and GE on the same 2.5-Gbps aggregated signal carried over a 10-Gbps ITU trunk card
39.2 µs (7.8 km)
77.1 µs (15.4 km)
151.1 µs (30.2 km)
1 The latency values are based on configuration of correct transmit buffer sizes as described in the Cisco ONS 15530 Configuration Guide.
2 GE = Gigabit Ethernet
3 FC = Fibre Channel
4 FICON = Fiber Connection
5 ITU = International Telecommunication Union
8-Port Multi-Service Muxponder Specifications
Table A-18 lists the 8-port multi-service muxponder receiver and transmitter specifications. Optical loss because of splitter modules and connectors should be included in the optical budget calculation.
Note The optical specifications described in this section are only for the individual components and should not be used to characterize the entire network performance.
Table A-18 8-Port Multi-Service Muxponder ITU Trunk Specifications
Description SpecificationFiber type
G.652 (SMF-25)
Connector
MU-PC
Receiver sensitivity Dispersion-26 dBm
20 dB
±1000 ps/nm3
-24 dBm
21 dB
1000 to 2100 ps/nm
-23 dBm
2 dB
2100 to 3200 ps/nm
Receiver Minimum MaximumOverload
-8 dBm
Wavelength
1260 nm
1580 nm
Transmitter Minimum MaximumTransmitter power
5 dBm
10 dBm
1 OSNR = optical signal-to-noise ratio.
2 Add the proper network-level penalty to the OSNR and/or receive power based on your actual network topology characteristics, such as dispersion.
3 ps/nm = picoseconds per nanometer.
The SFPs supported on the 8-port multi-service muxponder are shown in Table A-19. The optical power characteristics and other specifications of the supported SFPs are listed in the "SFP Specifications" section. Only use Cisco-certified SFPs for the 8-port multi-service muxponder.
Note The optical specifications described in this section are only for the individual components and should not be used to characterize the entire network performance.
Table A-19 SFPs Supported by the 8-Port Multi-Service Muxponder
Part Number Protocols or Clock Rate Range Supported15500-XVRA-10A2
Low band 8 Mbps to 200 Mbps
15500-XVRA-10B2
Low band 8 Mbps to 200 Mbps
15500-XVRA-11A2
Mid-band 200 Mbps to 622 Mbps
15500-XVRA-11B2
Mid-band 200 Mbps to 1.25 Gbps
15500-XVRA-12B1
High-band 1.062 Gbps to 2.488 Gbps
15500-XVRA-08D1
T11 1.544 Mbps
15500-XVRA-09D1
E1 2.044 Mbps
15500-XVRA-10E1
15500-XVRA-11D1
GE 1.25 Gbps, FE 1.25 Mbps4
ONS-SE-GEFC-SX
Fibre Channel (2.125 Gbps), Fibre Channel (1 Gbps), Gigabit Ethernet
1 DSX-1 interface
2 In a normal operating environment, the maximum digital video application connection length using a Belden 1694A cable is 200 m (218 yd). If the chassis ambient operating temperature is above 45°C (113° F) and ports 0 and 1 are used for video applications with this SFP, the maximum cable connection length supported may be less than the specified 200 m (218 yd), depending on the operating environment.
3 DVB-ASI = Digital Video Broadcast Asynchronous Serial Interface.
4 To ensure proper operation of the 15500-XVRA-11D1 SFP, the ambient operating temperature should not exceed 45°C (113°F).
Table A-20 lists the typical latencies for the 8-port multi-service muxponder.
SDI Jitter Performance
SDI video signal is compliant to the ANSI/SMPTE 259M-1997 standard. Table A-21 lists the SDI jitter performance values for the 8-port multi-service muxponder.
Table A-21 SDI Jitter Performance Values for the 8-Port Multi-Service Muxponder
Hp Filter 10 Hz 1 kHz 10 kHz 100 kHzJitter Generation (p-p)
0.5 UI1
0.06 UI
0.06 UI
0.06 UI
UI / Time
1.85 ns
220 ps
220 ps
220 ps
1 Maximum jitter generation is below SMPTE 259 M specification of 0.2 UI (0.74 ns) with the exception of low-frequency timing jitter. However, a purely digital system will operate correctly with significant amounts of low-frequency jitter as also indicated in Annex B of SMPTE 259M of the Timing Jitter Specification.
If your configuration uses an on-board system clock for trunk multiplexing, the client OC-3 wander generation may exceed the GR-253 specification of less than 60 ns MTIE (maximum time interval error) on greater than 10-second intervals and 20 ns MTIE on less than 1-second intervals. Because the MTIE can reach 100 ns across all observation intervals with this configuration, we do not recommend using the OC-3 transport for deriving the network clock. Other applications operate normally. If needed, the trunk multiplex clock can be configured to use one of the client OC-3 receive clocks. In this configuration, the OC-3 wander generation is fully compliant to GR-253 specification.
2.5-Gbps ITU Trunk Card Specifications
Table A-22 lists the 2.5-Gbps ITU trunk card receiver and transmitter specifications. Optical loss due to splitter modules and connectors should be included in the optical budget calculation.
Note The optical specifications described in this section are only for the individual components and should not be used to characterize the entire network performance.
Table A-22 2.5-Gbps ITU Trunk Card Optical Specifications
Description SpecificationFiber type
SM1 9 micron
Connector
MU
Receiver Minimum Maximum19 dB
Receive sensitivity 3
-28 dBm
Receive overload
-8 dBm
Input wavelength
1260 nm
1580 nm
Transmitter Minimum MaximumTransmitter power
5 dBm
10 dBm
Dispersion tolerance
3200 ps/nm4
1 SM = single mode.
2 OSNR = optical signal-to-noise ratio.
3 Add the proper network-level penalty to the OSNR and/or receive power based on your actual network topology characteristics, such as dispersion.
4 ps/nm = picoseconds per nanometer.
10-Gbps ITU Tunable and Non tunable Trunk Card Specifications
Table A-23 lists the specifications for tunable and non tunable 10-Gbps ITU trunk card for the client side lasers. Optical loss due to splitter modules and connectors should be included in the optical budget calculation.
Note The optical specifications described in this section are only for the individual components and should not be used to characterize the entire network performance.
Table A-23 10-Gbps ITU Tunable and Non tunable Trunk Card Specifications
Description SpecificationFiber type
ITU-T G.652
Connector
MU
Receiver Minimum Maximum26 dB
Receive sensitivity 2
-22 dBm
Receive overload
-8 dBm
Input wavelength
1430 nm
1580 nm
Transmitter Minimum MaximumOutput power
1 dBm
6 dBm
Dispersion tolerance
± 1000 ps/nm3
1 OSNR = optical signal-to-ratio.
2 Add the proper network level penalty to the OSNR and/or receive power based on your actual network topology characteristics, such as dispersion.
3 ps/nm = picosecond per nanometer.
10-Gbps Uplink Card
Table A-24 lists the specifications for the 10-Gbps uplink cards supported by the Cisco ONS 15530 in the transmit and receive directions.
Note The optical specifications described in this section are only for the individual components and should not be used to characterize the entire network performance.
Table A-24 10-Gbps Uplink Card Specifications
Description SpecificationFiber type
SM1 1310 nm
Connector
SC
Dimensions
10.4 x 1.105 x 8.797 in.
(264.2 x 28.1 x 223.4 mm)Bit rate
10 GE LAN-PHY
Receiver Minimum MaximumReceive sensitivity
-13.23 dBm
Receive overload
0.5 dBm
Stressed receive sensitivity
-10.3 dBm
Transmitter Minimum MaximumTransmit power
-5.2 dBm
0.5 dBm
Wavelength range
1260 nm
1355 nm
1 SM = single mode
SFP Specifications
Table A-25 lists the specifications for the Cisco ONS 15530 fixed rate SFP optics.
Note Only use Cisco-certified SFP optics for the 8-port FC/GE and ESCON aggregation cards.
Table A-26 lists the specifications for the Cisco ONS 15530 variable rate SFP optics.
Note Only use Cisco-certified SFP optics for the 4-port 1-Gbps/2-Gbps FC aggregation cards, 8-port FC/GE aggregation cards, 8-port multi-service muxponders, and ESCON aggregation cards.
Table A-26 Variable Rate SFP Optics Specifications
Description Specification Part number 15500-XVRA-10A1Supported protocol encapsulations
ESCON (MM)
Dimensions
0.486 x 0.522 x 2.24 in. (1.23 x 1325.9 x 5.69 cm)
Data rate
8 to 200 Mbps
Wavelength
1310 nm
Fiber type
MM 50/125 µm
MM 62.5/125 µmConnector type
LC
Receiver Minimum MaximumReceive sensitivity @10-12 BER1
-32 dBm
Receive sensitivity @10-15 BER
-29 dBm
Receive overload @10-12 BER
-14 dBm
Input wavelength
1100 nm
1600 nm
Transmitter Minimum MaximumTransmitter power
-19 dBm
-14 dBm
Output wavelength
1280 nm
1380 nm
Part number 15500-XVRA-10A2Supported protocol encapsulations
ESCON (MM)
Dimensions
0.486 x 0.522 x 2.24 in. (1.23 x 1325.9 x 5.69 cm)
Data rate
8 to 200 Mbps
Wavelength
1310 nm
Fiber type
MM 50/125 µm
MM 62.5/125 µmConnector type
LC
Receiver Minimum MaximumReceive sensitivity @10-12 BER2
-32 dBm
Receive sensitivity @10-15 BER
-29 dBm
Receive overload @10-12 BER
-14 dBm
Input wavelength
1100 nm
1600 nm
Transmitter Minimum MaximumTransmitter power
-19 dBm
-14 dBm
Output wavelength
1280 nm
1380 nm
Part number 15500-XVRA-10B1Supported protocol encapsulations
ESCON (SM)
Dimensions
0.486 x 0.522 x 2.24 in. (1.23 x 1325.9 x 5.69 cm)
Data rate range
8 Mbps to 200 Mbps
Wavelength
1310 nm
Fiber type
SM, 9/125 µm
Connector type
LC
Receiver Minimum MaximumReceive sensitivity @10-12 BER
-32 dBm
Receive overload @10-12 BER
-3 dBm
Input wavelength
1100 nm
1600 nm
Transmitter Minimum MaximumTransmitter power
-8 dBm
-4 dBm
Output wavelength
1260 nm
1360 nm
Part number 15500-XVRA-10B2Supported protocol encapsulations
ESCON (SM)
Dimensions
0.486 x 0.522 x 2.24 in. (1.23 x 1325.9 x 5.69 cm)
Data rate range
8 Mbps to 200 Mbps
Wavelength
1310 nm
Fiber type
SM, 9/125 µm
Connector type
LC
Receiver Minimum MaximumReceive sensitivity @10-12 BER
-32 dBm
Receive overload @10-12 BER
-3 dBm
Input wavelength
1100 nm
1600 nm
Transmitter Minimum MaximumTransmitter power
-8 dBm
-4 dBm
Output wavelength
1260 nm
1360 nm
Part number 15500-XVRA-11A1Supported protocol encapsulations
ESCON, OC-12/STM-4
Dimensions
0.486 x 0.522 x 2.24 in. (1.23 x 1325.9 x 5.69 cm)
Data rate range
200 Mbps to 622 Mbps
Wavelength
1310 nm
Fiber type
MM 62.5/125 µm
Connector type
LC
Receiver Minimum MaximumReceive sensitivity @10-10 BER
-26 dBm
Receive sensitivity @10-12 BER
-25 dBm
Maximum receive power @10-10 BER
-14
Input wavelength
1100 nm
1600 nm
Transmitter Minimum MaximumTransmitter power
-20 dBm
-14 dBm
Output wavelength
1270 nm
1380 nm
Part number 15500-XVRA-11A2Supported protocol encapsulations
ESCON, OC-12/STM-4
Dimensions
0.486 x 0.522 x 2.24 in. (1.23 x 1325.9 x 5.69 cm)
Data rate range
200 Mbps to 622 Mbps
Wavelength
1310 nm
Fiber type
MM 62.5/125 µm
Connector type
LC
Receiver Minimum MaximumReceive sensitivity @10-10 BER
-26 dBm
Receive sensitivity @10-12 BER
-25 dBm
Maximum receive power @10-10 BER
-14
Input wavelength
1100 nm
1600 nm
Transmitter Minimum MaximumTransmitter power
-20 dBm
-14 dBm
Output wavelength
1270 nm
1380 nm
Part number 15500-XVRA-11B1Supported protocol encapsulations
FC, FICON, GE, ISC-1
Dimensions
0.486 x 0.522 x 2.24 in. (1.23 x 1325.9 x 5.69 cm)
Data rate range
200 Mbps to 1.25 Gbps
Wavelength
1310 nm
Fiber type
SM, 9/125 µm
Connector type
LC
Receiver Minimum MaximumReceive sensitivity @10-12 BER
-19 dBm
Maximum receive power @10-12 BER
-3 dBm
Input wavelength
1100 nm
1600 nm
Transmitter Minimum MaximumTransmitter power
-11 dBm
-3 dBm
Output wavelength
1285 nm
1345 nm
Part number 15500-XVRA-11B2Supported protocol encapsulations
FC, FICON, GE, ISC-1
Dimensions
0.486 x 0.522 x 2.24 in. (1.23 x 1325.9 x 5.69 cm)
Data rate range
200 Mbps to 1.25 Gbps
Wavelength
1310 nm
Fiber type
SM, 9/125 µm
Connector type
LC
Receiver Minimum MaximumReceive sensitivity @10-12 BER
-19 dBm
Maximum receive power @10-12 BER
-3 dBm
Input wavelength
1100 nm
1600 nm
Transmitter Minimum MaximumTransmitter power
-11 dBm
-3 dBm
Output wavelength
1285 nm
1345 nm
Part number 15500-XVRA-12B1Supported protocol encapsulations
FC, FICON, GE, ISC-1, ISC-3
Dimensions
0.486 x 0.522 x 2.24 in (1.23 x 1325.9 x 5.69 cm)
Data rate range
1.062 Mbps to 2.488 Gbps
Wavelength
1310 nm
Fiber type
SM, 9/125 µm
Connector type
LC
Receiver Minimum MaximumReceive sensitivity @10-10 BER
-18 dBm
Maximum receive power @10-10 BER
-3 dBm
Input wavelength
1100 nm
1600 nm
Transmitter Minimum MaximumTransmitter power
-10 dBm
-3 dBm
Output wavelength
1266 nm
1360 nm
Part number 15454-SFP-GEFC-SXSupported protocol encapsulations
Fibre Channel (2.125 Gbps), Fibre Channel (1 Gbps), Gigabit Ethernet
Dimensions
0.486 x 0.522 x 2.24 in (1.23 x 1325.9 x 5.69 cm)
Data rate range
1.062 Gbps, 1.25 Gbps, 2.125 Gbps
Wavelength
830 to 860 nm
Fiber type
MM 50/125 µm, MM 62.5/125 µm
Connector type
Duplex LC
ReceiverReceive sensitivity @2.125 Gbps
-18 mW
Receive sensitivity @1.25 Gbps
-20 dBm
Receive sensitivity @1.06 Gbps
-20 mW
Maximum receive power
0 dBm
Receiver Minimum MaximumInput wavelength
770 nm
860 nm
Transmitter Minimum MaximumTransmitter power
-9 dBm
-3.5 dBm
Output wavelength
830 nm
860 nm
1 BER = bit error rate
2 BER = bit error rate
Table A-27 lists the specifications for the copper SFPs supported on the 8-port multi-service muxponder.
Posted: Wed Jul 5 19:20:55 PDT 2006
All contents are Copyright © 1992--2006 Cisco Systems, Inc. All rights reserved.
Important Notices and Privacy Statement.