cc/td/doc/product/mels/15530
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table Of Contents

Power-On Diagnostics Commands

diag power-on

diag power-on 2gfc

diag power-on carrier-mb

diag power-on cpu

diag power-on escon-10p

diag power-on fcge-8p

diag power-on itu2

diag power-on itu2-tun

diag power-on itu3

diag power-on mdx

diag power-on oscm

diag power-on psm

diag power-on tsp1

diag power-on voa

show diag power-on


Power-On Diagnostics Commands


Power-on diagnostics test the accessibility and basic functionality of the components and isolates the faults to the component level on the Cisco ONS 15530. All power-on diagnostics tests are enabled by default and can be disabled and monitored by using the commands described in this section.

diag power-on

To enable all power-on diagnostics for the system, use the diag power-on command. To disable all power-on diagnostics for the system, use the no form of this command.

diag power-on

no diag power-on

Syntax Description

This command has no other arguments or keywords.

Defaults

Enabled

Command Modes

Global configuration

Command History

This table includes the following release-specific history entries:

EV-Release

SV-Release

S-Release

EV-Release
Modification

12.1(12c)EV

This command was introduced.

SV-Release
Modification

12.2(18)SV

This command was integrated in this release.

S-Release
Modification

12.2(22)S

This command was integrated in this release from release 12.2(22)SV.

Usage Guidelines

Use this command to enable or disable all power-on diagnostics for the system. Power-on diagnostics run when the system powers up or reloads.

Examples

The following example shows how to enable power-on diagnostics.

Switch# configure terminal
Switch(config)# diag power-on

Related Commands

Command
Description

show diag power-on

Displays the power-on diagnostic test results.


diag power-on 2gfc

To enable power-on diagnostics for the 4-port 1-Gbps/2-Gbps FC aggregation card, use the diag power-on fcge-8p command. To disable power-on diagnostics for the 4-port 1-Gbps/2-Gbps FC aggregation card, use the no form of this command.

diag power-on 2gfc {aps-msg-int-bus | component-access | coney-fabric-lb | coney-qphy-lb | coney-serdes-lb | credit-buffer-mem | jtag-access | lrc-access | qphy-fabric-lb | qphy-internal-lb | sfp-xcvr-p0-idprom | sfp-xcvr-p1-idprom | sfp-xcvr-p2-idprom | sfp-xcvr-p3-idprom | sii-memory} slot slot-number

no diag power-on 2gfc {aps-msg-int-bus | component-access | coney-fabric-lb | coney-qphy-lb | coney-serdes-lb | credit-buffer-mem | jtag-access | lrc-access | qphy-fabric-lb | qphy-internal-lb | sfp-xcvr-p0-idprom | sfp-xcvr-p1-idprom | sfp-xcvr-p2-idprom | sfp-xcvr-p3-idprom | sii-memory} slot slot-number

Syntax Description

aps-msg-int-bus

Enables APS message interface tests.

component-access

Enables component access tests.

coney-fabric-lb

Coney switch loopback test.

coney-qphy-lb

Coney Quad PHY loopback test.

coney-serdes-lb

Coney Serdes loopback test.

credit-buffer-mem

Enables buffer credit memory tests.

jtag-access

Enables IDPROM checksum tests.

lrc-access

Enables LRC access tests.

qphy-fabriclb

Enables Quad PHY switch loopback test.

qphy-internal-lb

Enables Quad PHY internal loopback tests.

sfp-xcvr-p0-idprom

Enables port 0 transceiver IDPROM checksum tests.

sfp-xcvr-p1-idprom

Enables port 1 transceiver IDPROM checksum tests.

sfp-xcvr-p2-idprom

Enables port 2 transceiver IDPROM checksum tests.

sfp-xcvr-p3-idprom

Enables port 3 transceiver IDPROM checksum tests.

sii-memory

Enables SII memory tests.

slot slot-number

Specifies the number of the slot on which to perform the tests. The range is 1 to 10.

Note Slots 5 and 6 are reserved for the CPU switch modules.


Defaults

Enabled

Command Modes

Global configuration

Command History

This table includes the following release-specific history entries:

SV-Release

SV-Release
Modification

12.2(23)SV

This command was introduced.


Usage Guidelines

Use this command to enable or disable power-on diagnostics for 4-port 1-Gbps/2-Gbps FC aggregation cards. Power-on diagnostics run when the system powers up or reloads.


Note If the IDPROM checksum jtag-access test fails or is disabled, no other power-on diagnostics are performed for that 4-port 1-Gbps/2-Gbps FC aggregation card.


Examples

The following example shows how to enable power-on diagnostics.

Switch# configure terminal
Switch(config)# diag power-on 2gfc jtag-access slot 2

Related Commands

Command
Description

show diag power-on

Displays the power-on diagnostic test results.


diag power-on carrier-mb

To enable power-on diagnostics for carrier motherboards, use the diag power-on carrier-mb command. To disable power-on diagnostics for carrier motherboards, use the no form of this command.

diag power-on carrier-mb {aps-msg-int-bus | backplane-eth-lb | jtag-access | lrc-access}
slot slot-number

no diag power-on carrier-mb {aps-msg-int-bus | backplane-eth-lb | jtag-access | lrc-access}
slot slot-number

Syntax Description

aps-msg-int-bus

Enables APS message interface tests.

backplane-eth-lb

Enables LRC backplane Ethernet loopback tests.

jtag-access

Enables IDPROM checksum tests.

lrc-access

Enables LRC access tests.

slot slot-number

Specifies the number of the slot on which to perform the tests. The range is 1 to 10.

Note Slots 5 and 6 are reserved for the CPU switch modules.


Defaults

Enabled

Command Modes

Global configuration

Command History

This table includes the following release-specific history entries:

EV-Release

SV-Release

S-Release

EV-Release
Modification

12.1(12c)EV

This command was introduced.

SV-Release
Modification

12.2(18)SV

This command was integrated in this release.

S-Release
Modification

12.2(22)S

This command was integrated in this release from release 12.2(22)SV.

Usage Guidelines

Use this command to enable or disable power-on diagnostics for carrier motherboards. Power-on diagnostics run when the system powers up or reloads.


Note If the IDPROM checksum jtag-access test fails or is disabled, no other power-on diagnostics are performed for that carrier motherboard.


Examples

The following example shows how to enable power-on diagnostics.

Switch# configure terminal
Switch(config)# diag power-on carrier-mb backplane-eth-lb slot 2

Related Commands

Command
Description

show diag power-on

Displays the power-on diagnostic test results.


diag power-on cpu

To enable power-on diagnostics for CPU switch modules, use the diag power-on cpu command. To disable power-on diagnostics for CPU switch modules, use the no form of this command.

diag power-on cpu {bcom-sw-access | bcom-sw-config | bootflash | bp-idprom-test | cpu-l1-cache | cpu-l2-cache | gt-interrupt | gt-mii0-internal-lb | gt-mii1-internal-lb | gt-mpsc-internal-lb | gt-pci0 | interrupt0 | interrupt2 | interrupt3 | interrupt7 | interrupt8 | iofpga-access | nvram | power-supply0 | power-supply1 | src-access | src-timer | sw-fabric-config | system-tod | temp-sensor} slot slot-number

no diag power-on cpu {bcom-sw-access | bcom-sw-config | bootflash | bp-idprom-test | cpu-l1-cache | cpu-l2-cache | gt-interrupt | gt-mii0-internal-lb | gt-mii1-internal-lb | gt-mpsc-internal-lb | gt-pci0 | interrupt0 | interrupt2 | interrupt3 | interrupt7 | interrupt8 | iofpga-access | nvram | power-supply0 | power-supply1 | src-access | src-timer | sw-fabric-config | system-tod | temp-sensor} slot slot-number

Syntax Description

bcom-sw-access

Enables Ethernet switch access tests.

bcom-sw-config

Enables Ethernet switch config tests.

bootflash

Enables bootflash checksum tests.

bp-idprom-test

Enables backplane IDPROM checksum tests.

cpu-l1-cache

Enables CPU L1 cache tests.

cpu-l2-cache

Enables CPU L2 cache tests.

gt-interrupt

Enables GT interrupts tests.

gt-mii0-internal-lb

Enables GT MII0 internal loopback tests.

gt-mii1-internal-lb

Enables GT MII1 internal loopback tests.

gt-mpsc-internal-lb

Enables GT MPSC internal loopback tests.

gt-pci0

Enables GT PCI0 tests.

interrupt0

Enables CPU interrupt0 tests.

interrupt2

Enables CPU interrupt2 tests.

interrupt3

Enables CPU interrupt3 tests.

interrupt7

Enables CPU interrupt7 tests.

interrupt8

Enables CPU interrupt8 tests.

iofpga-access

Enables IOFPGA access tests.

nvram

Enables NVRAM tests.

power-suppy0

Enables power supply 0 IDPROM checksum tests.

power-supply1

Enables power supply 1 IDPROM checksum tests.

src-access

Enables SRC access tests.

src-timer

Enables SRC timer tests.

sw-fabric-config

Enables switch fabric configuration tests.

system-tod

Enables system Time Of Day tests.

temp-sensor

Enables temperature Sensor tests.

slot slot-number

Specifies the number of the slot on which to perform the tests. The range is 5 to 6.


Defaults

Enabled

Command Modes

Global configuration

Command History

This table includes the following release-specific history entries:

EV-Release

SV-Release

S-Release

EV-Release
Modification

12.1(12c)EV

This command was introduced.

SV-Release
Modification

12.2(18)SV

This command was integrated in this release.

S-Release
Modification

12.2(22)S

This command was integrated in this release from release 12.2(22)SV.

Usage Guidelines

Use this command to enable or disable power-on diagnostics for CPU switch modules. Power-on diagnostics run when the system powers up or reloads.

Examples

The following example shows how to enable power-on diagnostics.

Switch# configure terminal
Switch(config)# diag power-on cpu bootflash slot 5

Related Commands

Command
Description

show diag power-on

Displays the power-on diagnostic test results.


diag power-on escon-10p

To enable power-on diagnostics for the ESCON aggregation card, use the diag power-on escon-10p command. To disable power-on diagnostics for the ESCON aggregation card, use the no form of this command.

diag power-on escon-10p {aps-msg-int-bus | backplane-eth-lb | component-access | encap-lb | fabric-lb | jtag-access | lrc-access | qphy-lb} slot slot-number

no diag power-on escon-10p {aps-msg-int-bus | backplane-eth-lb | component-access | encap-lb | fabric-lb | jtag-access | lrc-access | qphy-lb} slot slot-number

Syntax Description

aps-msg-int-bus

Enables APS message interface tests.

backplane-eth-lb

Enables LRC backplane Ethernet loopback tests.

component-access

Enables component access tests.

encap-lb

Enables encapsulation FPGA loopback tests.

fabric-lb

Enables Quad PHY-to-switch fabric-to-Quad PHY tests.

jtag-access

Enables IDPROM checksum tests.

lrc-access

Enables LRC access tests.

qphy-lb

Enables Quad PHY loopback tests.

slot slot-number

Specifies the number of the slot on which to perform the tests. The range is 1 to 10.

Note Slots 5 and 6 are reserved for the CPU switch modules.


Defaults

Enabled

Command Modes

Global configuration

Command History

This table includes the following release-specific history entries:

EV-Release

SV-Release

S-Release

EV-Release
Modification

12.1(12c)EV

This command was introduced.

SV-Release
Modification

12.2(18)SV

This command was integrated in this release.

S-Release
Modification

12.2(22)S

This command was integrated in this release from release 12.2(22)SV.

Usage Guidelines

Use this command to enable or disable power-on diagnostics for ESCON aggregation cards. Power-on diagnostics run when the system powers up or reloads.


Note If the IDPROM checksum jtag-access test fails or is disabled, no other power-on diagnostics are performed for that ESCON aggregation card.


Examples

The following example shows how to enable power-on diagnostics.

Switch# configure terminal
Switch(config)# diag power-on escon-10p fabric-lb slot 2

Related Commands

Command
Description

show diag power-on

Displays the power-on diagnostic test results.


diag power-on fcge-8p

To enable power-on diagnostics for the 8-port FC/GE aggregation card, use the diag power-on fcge-8p command. To disable power-on diagnostics for the 8-port FC/GE aggregation card, use the no form of this command.

diag power-on fcge-8p {aps-msg-int-bus | backplane-eth-lb | component-access | credit-buffer-mem | hudson-montauk-lb | hudson-qphy-lb | hudson-swfabric-lb | jtag-access | lrc-access | qphy-int-lb | sfp-xcvr-p0-idprom | sfp-xcvr-p1-idprom | sfp-xcvr-p2-idprom | sfp-xcvr-p3-idprom | sfp-xcvr-p4-idprom | sfp-xcvr-p5-idprom | sfp-xcvr-p6-idprom | sfp-xcvr-p7-idprom | sii-memory} slot slot-number

no diag power-on fcge-8p {aps-msg-int-bus | backplane-eth-lb | component-access | credit-buffer-mem | hudson-montauk-lb | hudson-qphy-lb | hudson-swfabric-lb | jtag-access | lrc-access | qphy-int-lb | sfp-xcvr-p0-idprom | sfp-xcvr-p1-idprom | sfp-xcvr-p2-idprom | sfp-xcvr-p3-idprom | sfp-xcvr-p4-idprom | sfp-xcvr-p5-idprom | sfp-xcvr-p6-idprom | sfp-xcvr-p7-idprom | sii-memory} slot slot-number

Syntax Description

aps-msg-int-bus

Enables APS message interface tests.

backplane-eth-lb

Enables LRC backplane Ethernet loopback tests.

component-access

Enables component access tests.

credit-buffer-mem

Enables buffer credit memory tests.

hudson-montauk-lb

Enables performance monitor-to-aggregator-to-performance monitor loopback tests.

hudson-qphy-lb

Enables performance monitor-to-Quad PHY-to-performance monitor loopback tests.

hudson-swfabric-lb

Enables performance monitor-to-switch fabric-to-performance monitor loopback tests.

jtag-access

Enables IDPROM checksum tests.

lrc-access

Enables LRC access tests.

qphy-int-lb

Enables Quad PHY internal loopback tests.

sfp-xcvr-p0-idprom

Enables port 1 transceiver IDPROM checksum tests.

sfp-xcvr-p1-idprom

Enables port 2 transceiver IDPROM checksum tests.

sfp-xcvr-p2-idprom

Enables port 3 transceiver IDPROM checksum tests.

sfp-xcvr-p3-idprom

Enables port 4 transceiver IDPROM checksum tests.

sfp-xcvr-p4-idprom

Enables port 5 transceiver IDPROM checksum tests.

sfp-xcvr-p5-idprom

Enables port 6 transceiver IDPROM checksum tests.

sfp-xcvr-p6-idprom

Enables port 7 transceiver IDPROM checksum tests.

sfp-xcvr-p7-idprom

Enables port 8 transceiver IDPROM checksum tests.

sii-memory

Enables SII memory tests.

slot slot-number

Specifies the number of the slot on which to perform the tests. The range is 1 to 10.

Note Slots 5 and 6 are reserved for the CPU switch modules.


Defaults

Enabled

Command Modes

Global configuration

Command History

This table includes the following release-specific history entries:

EV-Release

SV-Release

S-Release

EV-Release
Modification

12.1(12c)EV

This command was introduced.

SV-Release
Modification

12.2(18)SV

This command was integrated in this release.

S-Release
Modification

12.2(22)S

This command was integrated in this release from release 12.2(22)SV.

Usage Guidelines

Use this command to enable or disable power-on diagnostics for 8-port FC/GE aggregation cards. Power-on diagnostics run when the system powers up or reloads.


Note If the IDPROM checksum jtag-access test fails or is disabled, no other power-on diagnostics are performed for that 8-port FC/GE aggregation card.


Examples

The following example shows how to enable power-on diagnostics.

Switch# configure terminal
Switch(config)# diag power-on fcge-8p credit-buffer-mem slot 2

Related Commands

Command
Description

show diag power-on

Displays the power-on diagnostic test results.


diag power-on itu2

To enable power-on diagnostics for 10-Gbps ITU trunk cards, use the diag power-on itu2 command. To disable power-on diagnostics for 10-Gbps ITU trunk cards, use the no form of this command.

diag power-on itu2 {aps-msg-int-bus | backplane-eth-lb | component-access | jtag-access | lrc-access | om-fifo | qphy-fabric-lb | sii-memory} slot slot-number

no diag power-on itu2 {aps-msg-int-bus | backplane-eth-lb | component-access | jtag-access | lrc-access | om-fifo | qphy-fabric-lb | sii-memory} slot slot-number

Syntax Description

aps-msg-int-bus

Enables APS message interface tests.

backplane-eth-lb

Enables LRC-to-backplane-Ethernet loopback tests.

component-access

Enables component access tests.

jtag-access

Enables IDPROM checksum tests.

lrc-access

Enables LRC access tests.

om-fifo

Enables optical message first-in first-out queue tests.

qphy-fabric-lb

Enables Quad PHY-to-switch fabric-to-Quad PHY tests.

sii-memory

Enables SII memory tests.

slot slot-number

Specifies the number of the slot on which to perform the tests. The range is 1 to 10.

Note Slots 5 and 6 are reserved for the CPU switch modules.


Defaults

Enabled

Command Modes

Global configuration

Command History

This table includes the following release-specific history entries:

EV-Release

SV-Release

S-Release

EV-Release
Modification

12.1(12c)EV

This command was introduced.

SV-Release
Modification

12.2(18)SV

This command was integrated in this release.

S-Release
Modification

12.2(22)S

This command was integrated in this release from release 12.2(22)SV.

Usage Guidelines

Use this command to enable or disable power-on diagnostics for 10-Gbps ITU trunk cards. Power-on diagnostics run when the system powers up or reloads.


Note If the IDPROM checksum jtag-access test fails or is disabled, no other power-on diagnostics are performed for that 10-Gbps ITU trunk card.


Examples

The following example shows how to enable power-on diagnostics.

Switch# configure terminal
Switch(config)# diag power-on itu2 component-access slot 2

Related Commands

Command
Description

show diag power-on

Displays the power-on diagnostic test results.


diag power-on itu2-tun

To enable power-on diagnostics for 10-Gbps ITU tunable trunk cards, use the diag power-on itu2-tun command. To disable power-on diagnostics for 10-Gbps ITU tunable trunk cards, use the no form of this command.

diag power-on itu2-tun {aps-msg-int-bus | backplane-eth-lb | component-access | jtag-access | lrc-access | om-fifo | qphy-fabric-lb | sii-memory} slot slot-number

no diag power-on itu2-tun {aps-msg-int-bus | backplane-eth-lb | component-access | jtag-access | lrc-access | om-fifo | qphy-fabric-lb | sii-memory} slot slot-number

Syntax Description

aps-msg-int-bus

Enables APS message interface tests.

backplane-eth-lb

Enables LRC-to-backplane-Ethernet loopback tests.

component-access

Enables component access tests.

jtag-access

Enables IDPROM checksum tests.

lrc-access

Enables LRC access tests.

om-fifo

Enables optical message first-in first-out queue tests.

qphy-fabric-lb

Enables Quad PHY-to-switch fabric-to-Quad PHY tests.

sii-memory

Enables SII memory tests.

slot slot-number

Specifies the number of the slot on which to perform the tests. The range is 1 to 10.

Note Slots 5 and 6 are reserved for the CPU switch modules.


Defaults

Enabled

Command Modes

Global configuration

Command History

This table includes the following release-specific history entries:

SV-Release

SV-Release
Modification

12.2(26)SV

This command was integrated in this release.


Usage Guidelines

Use this command to enable or disable power-on diagnostics for 10-Gbps ITU tunable trunk cards. Power-on diagnostics run when the system powers up or reloads.


Note If the IDPROM checksum jtag-access test fails or is disabled, no other power-on diagnostics are performed for 10-Gbps ITU tunable trunk card.


Examples

The following example shows how to enable power-on diagnostics.

Switch# configure terminal
Switch(config)# diag power-on itu2-tun component-access slot 2

Related Commands

Command
Description

show diag power-on

Displays the power-on diagnostic test results.


diag power-on itu3

To enable power-on diagnostics for 2.5-Gbps ITU trunk cards, use the diag power-on itu3 command. To disable power-on diagnostics for 2.5-Gbps ITU trunk cards, use the no form of this command.

diag power-on itu3 {aps-msg-int-bus | backplane-eth-lb | component-access | cpu-serdes-lb | jtag-access | lrc-access | om-fifo | ponte-qphy-lb | ponte-serdes-lb | qphy-internal-lb | qphy-switch-lb} slot slot-number

no diag power-on itu3 {aps-msg-int-bus | backplane-eth-lb | component-access | cpu-serdes-lb | jtag-access | lrc-access | om-fifo | ponte-qphy-lb | ponte-serdes-lb | qphy-internal-lb | qphy-switch-lb} slot slot-number

Syntax Description

aps-msg-int-bus

Enables APS message interface tests.

backplane-eth-lb

Enables LRC-to-backplane-Ethernet loopback tests.

component-access

Enables component access tests.

cpu-serdes-lb

Enables the CPU serializer/deserialize loopback tests.

jtag-access

Enables IDPROM checksum tests.

lrc-access

Enables LRC access tests.

om-fifo

Enables optical management first-in first-out queue tests.

ponte-qphy-lb

Enables performance-monitor-to-Quad-PHY loopback tests.

ponte-serdes-lb

Enables performance-monitor-to-serializer/deserializer loopback tests.

qphy-internal-lb

Enables internal Quad PHY loopback tests.

qphy-switch-lb

Enables switch loopback tests.

slot slot-number

Specifies the number of the slot on which to perform the tests. The range is 1 to 10.

Note Slots 5 and 6 are reserved for the CPU switch modules.


Defaults

Enabled

Command Modes

Global configuration

Command History

This table includes the following release-specific history entries:

EV-Release

SV-Release

S-Release

EV-Release
Modification

12.1(12c)EV2

This command was introduced.

SV-Release
Modification

12.2(18)SV

This command was integrated in this release.

S-Release
Modification

12.2(22)S

This command was integrated in this release from release 12.2(22)SV.

Usage Guidelines

Use this command to enable or disable power-on diagnostics for 2.5-Gbps ITU trunk cards. Power-on diagnostics run when the system powers up or reloads.


Note If the IDPROM checksum jtag-access test fails or is disabled, no other power-on diagnostics are performed for that 2.5-Gbps ITU trunk card.


Examples

The following example shows how to enable power-on diagnostics.

Switch# configure terminal
Switch(config)# diag power-on itu3 cpu-serdes-lb slot 8

Related Commands

Command
Description

show diag power-on

Displays the power-on diagnostic test results.


diag power-on mdx

To enable power-on diagnostics for OADM modules, use the diag power-on mdx command. To disable power-on diagnostics for OADM modules, use the no form of this command.

diag power-on mdx idprom subslot slot/subcard

no diag power-on mdx idprom subslot slot/subcard

Syntax Description

idprom

Enables the IDPROM tests.

subslot slot/subcard

Specifies the slot and subcard of the OADM modules. The value for slot is 0 and the values for subcard is 0 or 1.


Defaults

Enabled

Command Modes

Global configuration

Command History

This table includes the following release-specific history entries:

EV-Release

SV-Release

S-Release

EV-Release
Modification

12.1(12c)EV

This command was introduced.

SV-Release
Modification

12.2(18)SV

This command was integrated in this release.

S-Release
Modification

12.2(22)S

This command was integrated in this release from release 12.2(22)SV.

Usage Guidelines

Use this command to enable or disable power-on diagnostics for OADM modules. Power-on diagnostics run when the system powers up or reloads.

Examples

The following example shows how to enable power-on diagnostics.

Switch# configure terminal
Switch(config)# diag power-on mdx idprom subslot 0/1

Related Commands

Command
Description

show diag power-on

Displays the power-on diagnostic test results.


diag power-on oscm

To enable power-on diagnostics for OSC modules, use the diag power-on oscm command. To disable power-on diagnostics for OSC modules, use the no form of this command.

diag power-on oscm {hudjr-access | hudjr-internal-lb | idprom | serdes-lb}
subslot slot/subcard

no diag power-on oscm {hudjr-access | hudjr-internal-lb | idprom | serdes-lb}
subslot slot/subcard

Syntax Description

hudjr-access

Enables performance monitor access tests.

hudjr-internal-lb

Enables performance monitor Internal loopback tests.

idprom

Enables IDPROM checksum tests.

serdes-lb

Enables SerDes loopback tests.

subslot slot/subcard

Specifies the number of the slot on which to perform the tests. The slot range is 1 to 10. The subcard range is 0 to 1.

Note Slots 5 and 6 are reserved for the CPU switch modules.


Defaults

Enabled

Command Modes

Global configuration

Command History

This table includes the following release-specific history entries:

EV-Release

SV-Release

S-Release

EV-Release
Modification

12.1(12c)EV

This command was introduced.

SV-Release
Modification

12.2(18)SV

This command was integrated in this release.

S-Release
Modification

12.2(22)S

This command was integrated in this release from release 12.2(22)SV.

Usage Guidelines

Use this command to enable or disable power-on diagnostics for OSC modules. Power-on diagnostics run when the system powers up or reloads.


Note If the IDPROM checksum idprom test fails or is disabled, no other power-on diagnostics are performed for that OSC module.


Examples

The following example shows how to enable power-on diagnostics.

Switch# configure terminal
Switch(config)# diag power-on oscm hudjr-access subslot 2/0

Related Commands

Command
Description

show diag power-on

Displays the power-on diagnostic test results.


diag power-on psm

To enable power-on diagnostics for PSMs (protection switch modules), use the diag power-on psm command. To disable power-on diagnostics for PSMs, use the no form of this command.

diag power-on psm {aps-test | idprom | lol-test | psm-access | temp-sensor}
subslot slot/subcard

no diag power-on psm {aps-test | idprom | lol-test | psm-access | temp-sensor}
subslot slot/subcard

Syntax Description

aps-test

Enables APS (Automatic Protection Switching) tests.

idprom

Enables IDPROM checksum tests.

lol-test

Enables Loss of Light tests.

psm-access

Enables PSM access tests.

temp-sensor

Enables temperature sensor tests.

subslot slot/subcard

Specifies the number of the slot on which to perform the tests. The slot is 0 and the subcard range is 0 to 1.


Defaults

Enabled

Command Modes

Global configuration

Command History

This table includes the following release-specific history entries:

EV-Release

SV-Release

S-Release

EV-Release
Modification

12.1(12c)EV2

This command was introduced.

SV-Release
Modification

12.2(18)SV

This command was integrated in this release.

S-Release
Modification

12.2(22)S

This command was integrated in this release from release 12.2(22)SV.

Usage Guidelines

Use this command to enable or disable power-on diagnostics for PSMs. Power-on diagnostics run when the system powers up or reloads.


Note If the IDPROM checksum idprom test fails or is disabled, no other power-on diagnostics are performed for that PSM.


Examples

The following example shows how to enable power-on diagnostics.

Switch# configure terminal
Switch(config)# diag power-on psm temp-sensor subslot 0/0

Related Commands

Command
Description

show diag power-on

Displays the power-on diagnostic test results.


diag power-on tsp1

To enable power-on diagnostics for transponder line cards, use the diag power-on tsp1 command. To disable power-on diagnostics for transponder line cards, use the no form of this command.

diag power-on tsp1 {aps-msg-int-bus | backplane-eth-lb | hudjr-access | hudjr-egress-internal-lb | hudjr-egress-serdes-lb | hudjr-ingress-internal-lb | hudjr-ingress-serdes-lb | jtag-access | lrc-access} slot slot-number

no diag power-on tsp1 {aps-msg-int-bus | backplane-eth-lb | hudjr-access | hudjr-egress-internal-lb | hudjr-egress-serdes-lb | hudjr-ingress-internal-lb | hudjr-ingress-serdes-lb | jtag-access | lrc-access} slot slot-number

Syntax Description

aps-msg-int-bus

Enables APS message interface tests.

backplane-eth-lb

Enables LRC bp ethernet loopback tests.

hudjr-access

Enables performance monitor access tests.

hudjr-egress-internal-lb

Enables performance monitor egress internal loopback tests.

hudjr-egress-serdes-lb

Enables performance monitor egress SerDes loopback tests.

hudjr-ingress-internal-lb

Enables performance monitor ingress internal loopback tests.

hudjr-ingress-serdes-lb

Enables performance monitor ingress SerDes loopback tests.

jtag-access

Enables IDPROM checksum tests.

lrc-access

Enables LRC access tests.

slot slot-number

Specifies the number of the slot on which to perform the tests. The range is 1 to 10.

Note Slots 5 and 6 are reserved for the CPU switch modules.


Defaults

Enabled

Command Modes

Global configuration

Command History

This table includes the following release-specific history entries:

EV-Release

SV-Release

S-Release

EV-Release
Modification

12.1(12c)EV

This command was introduced.

SV-Release
Modification

12.2(18)SV

This command was integrated in this release.

S-Release
Modification

12.2(22)S

This command was integrated in this release from release 12.2(22)SV.

Usage Guidelines

Use this command to enable or disable power-on diagnostics for transponder line cards. Power-on diagnostics run when the system powers up or reloads.


Note If the IDPROM checksum jtag-access test fails or is disabled, no other power-on diagnostics are performed for that transponder line card.


Examples

The following example shows how to enable power-on diagnostics.

Switch# configure terminal
Switch(config)# diag power-on tsp1 lrc-access slot 2

Related Commands

Command
Description

show diag power-on

Displays the power-on diagnostic test results.


diag power-on voa

To enable power-on diagnostics for VOA modules, use the diag power-on voa command. To disable power-on diagnostics for VOA modules, use the no form of this command.

diag power-on voa {config-interface | idprom} subslot slot/subcard

no diag power-on voa {config-interface | idprom} subslot slot/subcard

Syntax Description

config-interface

Enables configuration interface tests.

idprom

Enables IDPROM checksum tests.

subslot slot/subcard

Specifies the number of the slot on which to perform the tests. The slot range is 1 to 10 and the subcard range is 0 to 1

Note Slots 5 and 6 are reserved for the CPU switch modules.


Defaults

Enabled

Command Modes

Global configuration

Command History

This table includes the following release-specific history entries:

EV-Release

SV-Release

S-Release

EV-Release
Modification

12.1(12c)EV

This command was introduced.

SV-Release
Modification

12.2(18)SV

This command was integrated in this release.

S-Release
Modification

12.2(22)S

This command was integrated in this release from release 12.2(22)SV.

Usage Guidelines

Use this command to enable or disable power-on diagnostics for VOA modules, WB-VOA modules and PB-OE modules. Power-on diagnostics run when the system powers up or reloads.


Note If the IDPROM checksum idprom test fails or is disabled, no other power-on diagnostics are performed for that VOA module.


Examples

The following example shows how to enable power-on diagnostics.

Switch# configure terminal
Switch(config)# diag power-on voa config-interface slot 2/1

Related Commands

Command
Description

show diag power-on

Displays the power-on diagnostic test results.


show diag power-on

To display the power-on diagnostic test results, use the show diag power-on command.

show diag power-on [detail | slot slot-number]

Syntax Description

detail

Displays the results of the power-on diagnostic tests for the entire system.

slot slot-number

Displays the results of the power-on diagnostic tests for the specified slot.


Defaults

Displays summary information for all components on the shelf.

Command Modes

Global configuration

Command History

This table includes the following release-specific history entries:

EV-Release

SV-Release

S-Release

EV-Release
Modification

12.1(12c)EV

This command was introduced.

SV-Release
Modification

12.2(18)SV

This command was integrated in this release.

S-Release
Modification

12.2(22)S

This command was integrated in this release from release 12.2(22)SV.

Usage Guidelines

Use this command to display the results of the power-on diagnostics.


Note All the power-on diagnostic tests run from the primary CPU switch module. Only CPU switch module related and basic line card access tests are performed from the secondary CPU switch module. The systems displays power-on diagnostic test results for the cards that are present at the time of system bootup. Any removal or insertion of cards does not change the output of these command.


Examples

The following example shows how to display the summarized power-on diagnostic results.

Switch# show diag power-on
--------------------------------------------------------------------------------
Power-on Diagnostics: Version 1.0
System-wide result: PASSED
Ran on: Mon Mar 13 2000 At: 03:45:13 UTC CPU was: Primary
--------------------------------------------------------------------------------

Slot/Subslot Card-type Result
~~~~~~~~~~~~ ~~~~~~~~~ ~~~~~~
0/1 mdx Passed
1/* tsp1 Passed
3/* itu2 Passed
4/* tsp1 Passed
6/* cpu Passed
7/* tsp1 Passed
8/* carrier-mb Passed
8/0 oscm Passed
8/1 oscm Passed
9/* escon-10p Passed
10/* tsp1 Passed

The following example shows how to display the detailed power-on diagnostic results.

Switch# show diag power-on detail
--------------------------------------------------------------------------------
Power-on Diagnostics: Version 1.0
System-wide result: FAILED
Ran on: Mon Mar 13 2000 At: 03:45:13 UTC CPU was: Primary
--------------------------------------------------------------------------------
Subslot: 0/1 mdx Result: Passed
H/w Ver: 1.0 FPGA func ver: N/A Versions compatible: N/A

Test-name Result Cause-code
~~~~~~~~~ ~~~~~~ ~~~~~~~~~~
idprom Passed -
--------------------------------------------------------------------------------
Slot: 1/* tsp1 Result: Passed
H/w Ver: 5.10 FPGA func ver: 3.12 Versions compatible: Yes

Test-name Result Cause-code
~~~~~~~~~ ~~~~~~ ~~~~~~~~~~
jtag-access Passed -
lrc-access Passed -
backplane-eth-lb Passed -
aps-msg-int-bus Passed -
hudjr-access Passed -
hudjr-ingress-inter Passed -
hudjr-ingress-serde Passed -
hudjr-egress-intern Passed -
hudjr-egress-serdes Passed -
--------------------------------------------------------------------------------
Slot: 3/* itu2 Result: Passed
H/w Ver: 4.9 FPGA func ver: 2.31 Versions compatible: Yes

Test-name Result Cause-code
~~~~~~~~~ ~~~~~~ ~~~~~~~~~~
jtag-access Passed -
lrc-access Passed -
backplane-eth-lb Passed -
aps-msg-int-bus Passed -
component-access Passed -
sii-memory Passed -
qphy-fabric-lb Passed -
om-fifo Passed -
--------------------------------------------------------------------------------
Slot: 4/* tsp1 Result: Passed
H/w Ver: 5.8 FPGA func ver: 3.12 Versions compatible: Yes

Test-name Result Cause-code
~~~~~~~~~ ~~~~~~ ~~~~~~~~~~
jtag-access Passed -
lrc-access Passed -
backplane-eth-lb Passed -
aps-msg-int-bus Passed -
hudjr-access Passed -
hudjr-ingress-inter Passed -
hudjr-ingress-serde Passed -
hudjr-egress-intern Passed -
hudjr-egress-serdes Passed -
--------------------------------------------------------------------------------
Slot: 6/* cpu Result: FAILED
H/w Ver: 4.6 FPGA func ver: 1.43 Versions compatible: Yes

Test-name Result Cause-code
~~~~~~~~~ ~~~~~~ ~~~~~~~~~~
cpu-l1-cache Passed -
cpu-l2-cache Passed -
gt-pci0 Passed -
iofpga-access Passed -
nvram Passed -
system-tod Passed -
bootflash Passed -
src-access Passed -
src-timer Passed -
sw-fabric-config Passed -
bcom-sw-access Passed -
bcom-sw-config Passed -
gt-mii0-internal-lb Passed -
gt-mii1-internal-lb Passed -
gt-mpsc-internal-lb Passed -
bp-idprom-test FAILED 1
power-supply0 FAILED 3
power-supply1 Passed -
temp-sensor Passed -
gt-interrupt Passed -
interrupt0 Passed -
interrupt2 Passed -
interrupt3 Passed -
interrupt7 Passed -
interrupt8 Passed -
--------------------------------------------------------------------------------
Slot: 7/* tsp1 Result: Passed
H/w Ver: 5.8 FPGA func ver: 3.12 Versions compatible: Yes

Test-name Result Cause-code
~~~~~~~~~ ~~~~~~ ~~~~~~~~~~
jtag-access Passed -
lrc-access Passed -
backplane-eth-lb Passed -
aps-msg-int-bus Passed -
hudjr-access Passed -
hudjr-ingress-inter Passed -
hudjr-ingress-serde Passed -
hudjr-egress-intern Passed -
hudjr-egress-serdes Passed -
--------------------------------------------------------------------------------
Slot: 8/* carrier-mb Result: Passed
H/w Ver: 4.2 FPGA func ver: 1.37 Versions compatible: Yes

Test-name Result Cause-code
~~~~~~~~~ ~~~~~~ ~~~~~~~~~~
jtag-access Passed -
lrc-access Passed -
backplane-eth-lb Passed -
aps-msg-int-bus Passed -
--------------------------------------------------------------------------------
Subslot: 8/0 oscm Result: Passed

Test-name Result Cause-code
~~~~~~~~~ ~~~~~~ ~~~~~~~~~~
hudjr-access Passed -
idprom Passed -
hudjr-internal-lb Passed -
serdes-lb Passed -
--------------------------------------------------------------------------------
Subslot: 8/1 oscm Result: Passed

Test-name Result Cause-code
~~~~~~~~~ ~~~~~~ ~~~~~~~~~~
hudjr-access Passed -
idprom Passed -
hudjr-internal-lb Passed -
serdes-lb Passed -
--------------------------------------------------------------------------------
Slot: 9/* escon-10p Result: Passed
H/w Ver: 3.4 FPGA func ver: 2.36 Versions compatible: Yes

Test-name Result Cause-code
~~~~~~~~~ ~~~~~~ ~~~~~~~~~~
jtag-access Passed -
lrc-access Passed -
backplane-eth-lb Passed -
aps-msg-int-bus Passed -
component-access Passed -
encap-lb Passed -
qphy-lb Passed -
fabric-lb Passed -
--------------------------------------------------------------------------------
Slot: 10/* tsp1 Result: Passed
H/w Ver: 5.9 FPGA func ver: 3.12 Versions compatible: Yes

Test-name Result Cause-code
~~~~~~~~~ ~~~~~~ ~~~~~~~~~~
jtag-access Passed -
lrc-access Passed -
backplane-eth-lb Passed -
aps-msg-int-bus Passed -
hudjr-access Passed -
hudjr-ingress-inter Passed -
hudjr-ingress-serde Passed -
hudjr-egress-intern Passed -
hudjr-egress-serdes Passed -
--------------------------------------------------------------------------------

Related Commands

Command
Description

diag power-on

Enables power-on diagnostics for the entire system.

diag power-on 2gfc

Enables power-on diagnostics for 4-port 1-Gbps/2-Gbps FC aggregation cards.

diag power-on carrier-mb

Enables power-on diagnostics for carrier motherboards.

diag power-on cpu

Enables power-on diagnostics for CPU switch modules.

diag power-on escon-10p

Enables power-on diagnostics for ESCON aggregation cards.

diag power-on fcge-8p

Enables power-on diagnostics for 8-port FC/GE aggregation cards.

diag power-on itu2

Enables power-on diagnostics for 10-Gbps ITU trunk cards.

diag power-on itu3

Enables power-on diagnostics for 2.5-Gbps ITU trunk cards.

diag power-on mdx

Enables power-on diagnostics for OADM modules.

diag power-on psm

Enables power-on diagnostics for PSMs.

diag power-on oscm

Enables power-on diagnostics for OSC modules.

diag power-on tsp1

Enables power-on diagnostics for transponder line cards.

diag power-on voa

Enables power-on diagnostics for VOA modules.



hometocprevnextglossaryfeedbacksearchhelp