This appendix contains the diagnostic error code numbers and a description of the cause.
| Error No. | Error Description |
|---|---|
| 1 | MEMDIAG data bus stuck 1 error |
| 2 | MEMDIAG data bus stuck 0 error |
| 3 | MEMDIAG data bus short error |
| 4 | MEMDIAG address bus stuck 1 error |
| 5 | MEMDIAG address bus stuck 0 error |
| 6 | MEMDIAG address bus short error |
| 7 | MEMDIAG BOOTROM descriptor checksum fail error |
| 8 | MEMDIAG BOOTROM image checksum fail error |
| 9 | MEMDIAG serial EEPROM write timeout error |
| 10 | MEMDIAG serial EEPROM data error |
| 11 | MEMDIAG serial EEPROM checksum fail error |
| 12 | MEMDIAG Flash descriptor checksum fail error |
| 13 | MEMDIAG Flash image checksum fail error |
| 14 | MEMDIAG DMP Flash invalid length error |
| 15 | MEMDIAG DMP Flash checksum fail error |
| 16 | MEMDIAG BOOTNVRAM checksum fail error |
| 17 | MEMDIAG NVRAM CRESMIB checksum fail error |
| 18 | MEMDIAG NVRAM SMTMIB checksum fail error |
| 19 | MEMDIAG NVRAM read write test fail error |
| 20 | MEMDIAG SRAM fast access test fail error |
| 21 | MEMDIAG SRAM read write test fail error |
| 22 | MEMDIAG DRAM fast access test fail error |
| 23 | MEMDIAG DRAM read write test fail error |
| 24 | MEMDIAG QSRAM fast access test fail error |
| 25 | MEMDIAG QSRAM read write test fail error |
| 26 | MEMDIAG FRAMEBUF fast access test fail error |
| 27 | MEMDIAG FRAMEBUF read write test fail error |
| 28 | IODIAG watchdog interrupt test fail error |
| 29 | IODIAG temperature high error |
| 30 | IODIAG fan 1 feedback fail error |
| 31 | IODIAG fan 2 feedback fail error |
| 32 | IODIAG power minus 12 fail error |
| 33 | IODIAG power plus 12 fail error |
| 34 | PHYDIAG PLC accessibility error |
| 35 | PHYDIAG interrupt test fail error |
| 36 | PHYDIAG media not present error |
| 37 | PHYDIAG master symbol loopback fail error |
| 38 | PHYDIAG halt symbol loopback fail error |
| 39 | PHYDIAG idle symbol loopback fail error |
| 40 | PHYDIAG quiet symbol loopback fail error |
| 41 | MACDIAG mac accessibility error |
| 42 | MACDIAG memory write ptr increment fail error |
| 43 | MACDIAG memory read ptr increment fail error |
| 44 | MACDIAG memory read ptr unexpected increment error |
| 45 | MACDIAG interrupt test fail error |
| 46 | MACDIAG BUFMEM read write test fail error |
| 47 | MACDIAG CAM not configured error |
| 48 | MACDIAG CAM data error |
| 49 | MACDIAG CAM data mismatch error |
| 50 | MACDIAG media not present error |
| 51 | MACDIAG ring not up after claim process error |
| 52 | MACDIAG status bit srcvfrm stuck error |
| 53 | MACDIAG status bit SRCOMP stuck error |
| 54 | MACDIAG packet transmit timeout error |
| 55 | MACDIAG packet receive timeout error |
| 56 | MACDIAG packet data error |
| 57 | MACDIAG PHY bypass configuration timeout error |
| 58 | MACDIAG PHY LMLOOP configuration timeout error |
| 59 | MACDIAG PHY EBLOOP configuration timeout error |
| 60 | MACDIAG PHY XTLOOP configuration timeout error |
| 61 | MACDIAG PHY PMDLOOP configuration timeout error |
| 62 | ETIDIAG accessibility error |
| 63 | ETIDIAG read RRA timeout error |
| 64 | ETIDIAG load CAM timeout error |
| 65 | ETIDIAG CAM CAP2 data error |
| 66 | ETIDIAG CAM CAP1 data error |
| 67 | ETIDIAG CAM CAP0 data error |
| 68 | ETIDIAG CAM enable data error |
| 69 | ETIDIAG transmit timeout error |
| 70 | ETIDIAG transmit byte count mismatch error |
| 71 | ETIDIAG transmit fifo underrun error |
| 72 | ETIDIAG transmit packet monitored bad error |
| 73 | ETIDIAG transmit CD heartbeat lost error |
| 74 | ETIDIAG transmit out of window collision error |
| 75 | ETIDIAG transmit excessive collisions error |
| 76 | ETIDIAG transmit CRS lost error |
| 77 | ETIDIAG transmit no CRS error |
| 78 | ETIDIAG transmit deferred transmission error |
| 79 | ETIDIAG transmit excessive deferral error |
| 80 | ETIDIAG transmit collisions error |
| 81 | ETIDIAG transmit packet not ok error |
| 82 | ETIDIAG receive timeout error |
| 83 | ETIDIAG RECEIVE FRAME ALIGNMENT ERROR |
| 84 | ETIDIAG RECEIVE CRC ERROR |
| 85 | ETIDIAG receive packet not ok error |
| 86 | ETIDIAG destination address mismatch error |
| 87 | ETIDIAG source address mismatch error |
| 88 | ETIDIAG invalid packetsize error |
| 89 | ETIDIAG packet data error |
| 90 | ETIDIAG QSRAM arbitration error |
| 91 | ETIDIAG framebuf arbitration error |
| 92 | ETIDIAG disable links timeout error |
| 93 | ETIDIAG enable links timeout error |
| 94 | ETIDIAG Ethernet bank a reset timeout error |
| 95 | ETIDIAG Ethernet bank b reset timeout error |
| 96 | BIGADIAG BIGA accessibility error |
| 97 | BIGADIAG BUFMEM read write test fail error |
| 98 | BIGADIAG status bit XMTD stuck error |
| 99 | BIGADIAG status bit RDSB stuck error |
| 100 | BIGADIAG status bit XMTD not set error |
| 101 | BIGADIAG status bit RDSB not set error |
| 102 | BIGADIAG packet transmit timeout error |
| 103 | BIGADIAG packet receive timeout error |
| 104 | BIGADIAG packet data error |
| 105 | BIGADIAG QSRAM arbitration error |
| 106 | BIGADIAG FRAMEBUF arbitration error |
|
|