This appendix contains the diagnostic error code numbers and a description of the cause.
Error No. | Error Description |
---|---|
1 | MEMDIAG data bus stuck 1 error |
2 | MEMDIAG data bus stuck 0 error |
3 | MEMDIAG data bus short error |
4 | MEMDIAG address bus stuck 1 error |
5 | MEMDIAG address bus stuck 0 error |
6 | MEMDIAG address bus short error |
7 | MEMDIAG BOOTROM descriptor checksum fail error |
8 | MEMDIAG BOOTROM image checksum fail error |
9 | MEMDIAG serial EEPROM write timeout error |
10 | MEMDIAG serial EEPROM data error |
11 | MEMDIAG serial EEPROM checksum fail error |
12 | MEMDIAG Flash descriptor checksum fail error |
13 | MEMDIAG Flash image checksum fail error |
14 | MEMDIAG DMP Flash invalid length error |
15 | MEMDIAG DMP Flash checksum fail error |
16 | MEMDIAG BOOTNVRAM checksum fail error |
17 | MEMDIAG NVRAM CRESMIB checksum fail error |
18 | MEMDIAG NVRAM SMTMIB checksum fail error |
19 | MEMDIAG NVRAM read write test fail error |
20 | MEMDIAG SRAM fast access test fail error |
21 | MEMDIAG SRAM read write test fail error |
22 | MEMDIAG DRAM fast access test fail error |
23 | MEMDIAG DRAM read write test fail error |
24 | MEMDIAG QSRAM fast access test fail error |
25 | MEMDIAG QSRAM read write test fail error |
26 | MEMDIAG FRAMEBUF fast access test fail error |
27 | MEMDIAG FRAMEBUF read write test fail error |
28 | IODIAG watchdog interrupt test fail error |
29 | IODIAG temperature high error |
30 | IODIAG fan 1 feedback fail error |
31 | IODIAG fan 2 feedback fail error |
32 | IODIAG power minus 12 fail error |
33 | IODIAG power plus 12 fail error |
34 | PHYDIAG PLC accessibility error |
35 | PHYDIAG interrupt test fail error |
36 | PHYDIAG media not present error |
37 | PHYDIAG master symbol loopback fail error |
38 | PHYDIAG halt symbol loopback fail error |
39 | PHYDIAG idle symbol loopback fail error |
40 | PHYDIAG quiet symbol loopback fail error |
41 | MACDIAG mac accessibility error |
42 | MACDIAG memory write ptr increment fail error |
43 | MACDIAG memory read ptr increment fail error |
44 | MACDIAG memory read ptr unexpected increment error |
45 | MACDIAG interrupt test fail error |
46 | MACDIAG BUFMEM read write test fail error |
47 | MACDIAG CAM not configured error |
48 | MACDIAG CAM data error |
49 | MACDIAG CAM data mismatch error |
50 | MACDIAG media not present error |
51 | MACDIAG ring not up after claim process error |
52 | MACDIAG status bit srcvfrm stuck error |
53 | MACDIAG status bit SRCOMP stuck error |
54 | MACDIAG packet transmit timeout error |
55 | MACDIAG packet receive timeout error |
56 | MACDIAG packet data error |
57 | MACDIAG PHY bypass configuration timeout error |
58 | MACDIAG PHY LMLOOP configuration timeout error |
59 | MACDIAG PHY EBLOOP configuration timeout error |
60 | MACDIAG PHY XTLOOP configuration timeout error |
61 | MACDIAG PHY PMDLOOP configuration timeout error |
62 | ETIDIAG accessibility error |
63 | ETIDIAG read RRA timeout error |
64 | ETIDIAG load CAM timeout error |
65 | ETIDIAG CAM CAP2 data error |
66 | ETIDIAG CAM CAP1 data error |
67 | ETIDIAG CAM CAP0 data error |
68 | ETIDIAG CAM enable data error |
69 | ETIDIAG transmit timeout error |
70 | ETIDIAG transmit byte count mismatch error |
71 | ETIDIAG transmit fifo underrun error |
72 | ETIDIAG transmit packet monitored bad error |
73 | ETIDIAG transmit CD heartbeat lost error |
74 | ETIDIAG transmit out of window collision error |
75 | ETIDIAG transmit excessive collisions error |
76 | ETIDIAG transmit CRS lost error |
77 | ETIDIAG transmit no CRS error |
78 | ETIDIAG transmit deferred transmission error |
79 | ETIDIAG transmit excessive deferral error |
80 | ETIDIAG transmit collisions error |
81 | ETIDIAG transmit packet not ok error |
82 | ETIDIAG receive timeout error |
83 | ETIDIAG RECEIVE FRAME ALIGNMENT ERROR |
84 | ETIDIAG RECEIVE CRC ERROR |
85 | ETIDIAG receive packet not ok error |
86 | ETIDIAG destination address mismatch error |
87 | ETIDIAG source address mismatch error |
88 | ETIDIAG invalid packetsize error |
89 | ETIDIAG packet data error |
90 | ETIDIAG QSRAM arbitration error |
91 | ETIDIAG framebuf arbitration error |
92 | ETIDIAG disable links timeout error |
93 | ETIDIAG enable links timeout error |
94 | ETIDIAG Ethernet bank a reset timeout error |
95 | ETIDIAG Ethernet bank b reset timeout error |
96 | BIGADIAG BIGA accessibility error |
97 | BIGADIAG BUFMEM read write test fail error |
98 | BIGADIAG status bit XMTD stuck error |
99 | BIGADIAG status bit RDSB stuck error |
100 | BIGADIAG status bit XMTD not set error |
101 | BIGADIAG status bit RDSB not set error |
102 | BIGADIAG packet transmit timeout error |
103 | BIGADIAG packet receive timeout error |
104 | BIGADIAG packet data error |
105 | BIGADIAG QSRAM arbitration error |
106 | BIGADIAG FRAMEBUF arbitration error |
|