Command
|
Syntax
|
Description
|
Type
|
Mode
|
atm-address
|
atm-address nsap-addr ubr+ pcr value mcr value
|
Overrides the control ATM address and allows you to specify the UBR+ parameters.
|
ATM
|
IC
|
atm bind pvc vlan
|
atm bind pvc vlan vcd vlan_num
|
Binds a PVC to a specified VLAN.
|
ATM
|
IC
|
atm clock internal1
|
atm clock internal no atm clock internal
|
Specifies the transmit clock source.
|
ATM
|
IC
|
atm ds3-scramble
|
atm ds-3 scramble no atm ds-3 scramble
|
Enables or disables scrambling on the current port.
|
ATM
|
IC
|
atm framing
|
atm framing [m23adm | cbitplcp | m23plcp] no atm framing
|
Changes the default DS3 line framing.
|
ATM
|
IC
|
atm ilmi-enable
|
atm ilmi-enable no atm ilmi-enable
|
Enables or disables the ILMI.
|
ATM
|
IC
|
atm ilmi-keepalive
|
atm ilmi-keepalive seconds no atm ilmi-keepalive seconds
|
Enables ILMI keepalives.
|
ATM
|
IC
|
atm lbo
|
atm lbo {short | long}
|
Sets the line buildout corresponding to the cable length.
|
ATM
|
IC
|
atm preferred phy
|
atm preferred phy {A | B}
|
Changes the preferred PHY.
|
ATM
|
IC
|
atm pvc
|
atm pvc vcd vpi vci [aal5snap | ilmi | qsaal] atm pvc vcd vpi vci [aal5snap | ilmi | qsaal] [peak_rate average_rate [burst_size]] [oam seconds]2 no atm pvc vcd vpi vci
|
Creates a PVC on the ATM interface.
|
ATM
|
IC
|
atmsig close
|
atmsig close atm0 vcd
|
Disconnects an SVC.
|
ATM
|
IC
|
atm sonet3
|
atm sonet {stm-1 | sts-3c} {stm-4 | sts-12c} no atm sonet
|
Sets the mode of operation and control type for cell-rate decoupling.
|
ATM
|
IC
|
atm traffic-shape rate
|
atm traffic-shape rate 1-155 no atm traffic-shape rate
|
Configures output throttling on the ATM module.
|
ATM
|
IC
|
atm uni-version
|
atm uni-version version_num no atm uni-version
|
Specifies the UNI version to be used.
|
ATM
|
GC
|
atm vc-per-vp
|
atm vc-per-vp num no atm vc-per-vp
|
Sets the maximum number of VCIs to support per VCI.
|
ATM
|
IC
|
clear mpoa client cache
|
clear mpoa client [name mpc_name] cache [ingress | egress] [ip-address ip-address]
|
Clears ingress/egress cache entries of one or all MPCs.
|
ATM
|
EXEC
|
client-atm-address name
|
client-atm-address atm-address-template name elan-name no client-atm-address atm-address-template
|
Adds a LANE address entry to the configuration server's database.
|
ATM
|
Dbase
|
debug mpoa client
|
debug mpoa client {all | data | egress | general | ingress | keep-alives | platform-specific} [name mpc_name] no debug mpoa client [name mpc_name]
|
Displays debug information for the MPC.
|
ATM
|
EXEC
|
default-name
|
default-name elan-name no default name
|
Provides a default ELAN name in the configuration server's database.
|
ATM
|
Dbase
|
disableATM
|
disable [level]
|
Exits privileged EXEC mode and returns to user EXEC mode.
|
ATM
|
EXEC
|
display-databases
|
display-databases
|
Displays all the LECS database tables.
|
ATM
|
Dbase
|
editing
|
editing no editing
|
Enables enhanced editing mode.
|
ATM
|
Line
|
enableATM
|
enable
|
Enters privileged EXEC mode.
|
ATM
|
EXEC
|
end
|
end
|
Exits configuration mode.
|
ATM
|
GC
|
exit
|
exit
|
Exits any command mode or closes an active terminal session and terminates the EXEC.
|
ATM
|
All
|
help
|
help
|
Displays the help commands.
|
ATM
|
All
|
historyATM
|
history [size number-of-lines] no history
|
Enables the command history function.
|
ATM
|
Line
|
interface
|
interface atm_num[.sub_interface_num mul] | loopback_num
|
Enters the configure interface or subinterface mode.
|
ATM
|
IC
|
lane auto-config-atm-address
|
lane [config] auto-config-atm-address no lane [config] auto-config-atm-address
|
Specifies the ATM address is computed automatically.
|
ATM
|
IC
|
lane bus-atm-address
|
lane bus-atm-address bus_name atm-addr no lane bus-atm-address bus_name atm-addr
|
Sets the ATM address for the BUS.
|
ATM
|
IC
|
lane client
|
lane client [ethernet vlan_num [elan-name]] no lane client [ethernet vlan_num [elan-name]]
|
Activates a LANE client.
|
ATM
|
IC
|
lane client-atm-address
|
lane client-atm-address atm-address-template no client-atm-address [atm-address-template]
|
Specifies an ATM address for the LANE client (overriding automatic assignment).
|
ATM
|
IC
|
lane client mpoa client name
|
lane client mpoa client name mpc-name no lane client mpoa client name mpc-name
|
Binds a LEC to the named MPC.
|
ATM
|
IC
|
lane client qos
|
lane client qos database_name
|
Applies the database to an interface
|
ATM
|
IC
|
lane config-atm-address
|
lane config-atm-address atm-address-template no lane config-atm-address [atm-address-template]
|
Specifies the ATM address of a given configuration server.
|
ATM
|
IC
|
lane config database
|
lane config database database-name no lane config database
|
Associates a named configuration database with the configuration server on the selected ATM interface.
|
ATM
|
GC
|
lane database
|
lane database database-name no lane database database-name
|
Creates a named configuration database that can be associated with a configuration server.
|
ATM
|
GC
|
lane le-arp
|
lane le-arp mac-addr atm-addr no lane le-arp mac-addr atm-addr
|
Adds a static entry to the LE ARP table.
|
ATM
|
IC
|
lane qos database
|
[no] lane qos database name
|
Creates a LANE QoS database.
|
ATM
|
GC
|
lane qos iptos trust
|
[no] lane qos iptos trust
|
Sets the LANE QoS mode.
|
ATM
|
GC
|
lane register
|
lane register vcd mac-addr atm-addr no lane register vcd [mac-addr atm-addr]
|
Registers a LANE client.
|
ATM
|
IC
|
lane server-atm-address
|
lane server-atm-address les_name atm-address-template no lane server-atm-address les_name atm-address-template
|
Configures the LES ATM address template.
|
ATM
|
IC
|
lane server-bus
|
lane server-bus {ethernet | tokenring} elan_name [elan-id id] no lane server-bus {ethernet | tokenring} elan_name [elan-id id]
|
Configures the LES and BUS for the specified ELAN on the subinterface.
|
ATM
|
IC
|
mac-address
|
mac-address ieee-address
|
Defines the MAC layer address.
|
ATM
|
IC
|
mpoa client config name
|
mpoa client config name mpc-name no mpoa client config name mpc-name
|
Defines an MPC with a specified name.
|
ATM
|
IC
|
mpoa client name
|
mpoa client name mpc-name no mpoa client name mpc-name
|
Attaches an MPC to a major ATM interface.
|
ATM
|
IC
|
mtu
|
mtu size
|
Sets the interface MTU size.
|
ATM
|
IC
|
name
|
name elan-name elan-id id {local-seg-id | new-name | preempt | restricted | server-atm-address | un-restricted} atm-addr no name elan_name atm-addr
|
Assigns a unique ELAN name to a LES.4
|
ATM
|
Dbase
|
reloadATM
|
reload
|
Reloads the operating system.
|
ATM
|
EXEC
|
shortcut-frame-count
|
shortcut-frame-count count no shortcut-frame-count
|
Specifies the maximum number of times a packet can be routed to the default router within the shortcut-frame time before an MPOA resolution request is sent.
|
ATM
|
MPC
|
shortcut-frame-time
|
shortcut-frame-time time no shortcut-frame-time
|
Sets the shortcut-setup frame time (in seconds) for the MPC.
|
ATM
|
MPC
|
show atm ilmi-status atm
|
show atm ilmi-status atm mod_num/subcard_num/port_num
|
Displays ILMI information about the ATM interface.
|
ATM
|
EXEC
|
show atm interface atm0
|
show atm interface atm0
|
Displays information about the ATM interface.
|
ATM
|
EXEC
|
show atm traffic
|
show atm traffic
|
Displays global ATM traffic information.
|
ATM
|
EXEC
|
show atm vc
|
show atm vc [vcd]
|
Displays the active ATM virtual circuits.
|
ATM
|
EXEC
|
show atm vlan
|
show atm vlan [vlan_num]
|
Displays the active VLAN-to-PVC bindings.
|
ATM
|
EXEC
|
show history
|
show history
|
Lists the command history for the current EXEC session.
|
ATM
|
EXEC
|
show lane
|
show lane [interface atm0[.subinterface] | name elan-name] [brief]
|
Displays global and per-VCC LANE information.
|
ATM
|
EXEC
|
show lane bus
|
show lane bus [interface atm0[.subinterface] | name elan-name] [brief]
|
Displays LANE information for the configured BUS.
|
ATM
|
EXEC
|
show lane client
|
show lane client [interface atm0[.subinterface] | name elan-name] [brief]
|
Displays global and per-VCC LANE information.
|
ATM
|
EXEC
|
show lane config
|
show lane config [interface atm0] [brief]
|
Displays LANE information for the LECS.
|
ATM
|
EXEC
|
show lane default-atm-addresses
|
show lane default-atm-addresses
|
Displays default ATM addresses for dual PHYs.
|
ATM
|
EXEC
|
show lane le-arp
|
show lane le-arp [interface atm0[.subinterface] | name elan-name]
|
Displays the LE ARP table.
|
ATM
|
EXEC
|
show lane qos database
|
show lane qos database name
|
Displays the contents of a specific LANE QoS database
|
ATM
|
EXEC
|
show lane server
|
show lane server [interface atm0[.subinterface] | name elan-name] [brief]
|
Displays LANE information about the configured LES.
|
ATM
|
EXEC
|
show mpoa client
|
show mpoa client [name mpc-name] [brief]
|
Displays a summary of information regarding one/all MPCs.
|
ATM
|
EXEC
|
show mpoa client cache
|
show mpoa client [name mpc-name] cache [ingress | egress] [ip-address ip-address]
|
Displays the ingress and/or egress cache entries matching the IP addresses for the MPCs.
|
ATM
|
EXEC
|
show mpoa client statistics
|
show mpoa client [name mpc-name] statistics
|
Displays all the statistics collected by an MPC.
|
ATM
|
EXEC
|
show mpoa default-atm-addresses
|
show mpoa default-atm-addresses
|
Displays the default ATM addresses for the MPC.
|
ATM
|
EXEC
|
show sscop
|
show sscop
|
Displays SSCOP details for all ATM interfaces.
|
ATM
|
EXEC
|
show versionATM
|
show version
|
Displays version information for the ATM module.
|
ATM
|
EXEC
|
shutdown
|
shutdown no shutdown
|
Shuts down or restarts a physical interface.
|
Config
|
IC
|
sscop cc-timer
|
sscop cc-timer msecs no sscop cc-timer
|
Changes (in msecs) the SSCOP connection control timer value.
|
ATM
|
IC
|
sscop keepalive-timer
|
sscop keepalive-timer msecs no sscop keepalive-timer
|
Changes the SSCOP keepalive timer period (in msecs).
|
ATM
|
IC
|
sscop max-cc
|
sscop max-cc retries no sscop max-cc
|
Changes the maximum number of retries for connection control operations.
|
ATM
|
IC
|
sscop max-stat
|
sscop max-stat entries no sscop max-stat
|
Changes the maximum number of entries in a Stat frame.
|
ATM
|
IC
|
sscop poll-timer
|
sscop poll-timer msecs no sscop poll-timer
|
Changes the maximum time (in msecs) to wait for a response before sending a POLL PDU.
|
ATM
|
IC
|
sscop receive-window
|
sscop receive-window packets no sscop receive-window
|
Changes the size of the SSCOP receiver window.
|
ATM
|
IC
|
sscop send-window
|
sscop send-window packets no sscop send-window
|
Changes the size of the SSCOP transmitter window.
|
ATM
|
IC
|
terminal
|
terminal length [screen-length] terminal no length
|
Sets the number of lines displayed on the terminal.
|
ATM
|
EXEC
|
ubr+cos
|
ubr+ cos {value | range}
|
Maps the CoS value or range of values to a UBR+ VCC.
|
ATM
|
EXEC
|
write terminal
|
write terminal
|
Displays the ATM configuration information currently in running memory.
|
ATM
|
EXEC
|