The 2.2(1) and 2.2(2) software release supports the existing Catalyst 3000 switch family (including the Catalyst 3000, Catalyst 3100 and Catalyst 3200) and CPW1601, and introduces the following features:
For detailed information about configuring CGMP and DISL Protocols, refer to the 2.2(1) Configuration Note. For detailed information about configuring other features on a Catalyst 3000 series switch, refer to the Installation and Configuration Guide.
Caution As with other 2.0 and above releases, if you are upgrading a pre 2.0 system, you MUST upgrade the bootcode first. If you do not, the system will not boot when restarted. |
See the section "Downloading the 2.0 (or above) Image to a Pre 2.0 system" in the 2.0(1), 2.0(2), 2.0(3), 2.1(1) or 2.1(2) Release Notes for complete details.
The following are known conditions as of this version of the software release.
This limitation is described in detail in the CGMP section of the 2.2(1) Configuration Note. Multicast sources arriving at the Cat3000 via an ATM port cannot have the list of destination ports controlled by CGMP. This is a limitation of the ATM subsystem and is not planned to be fixed in any future release.
It is not possible to run CGMP and have Address Filtering in use at the same time. CGMP will override filter table entries.
SNMP Sets for the LANE server MIBs, CISCO-LECS-MIB, CISCO-LES-MIB and CISCO-BUS-MIB are not supported for the 2.2(2) release.
If spanning tree is disabled on a VLAN, from the console or SNMP, the per port address table entries are not updated. If BPDU's are received by the switch, they will be dropped, instead of being flooded.
If this is done on a network using spanning tree, this could potentially cause loops to form since the switch will continually drop BPDUs.
This problem will occur only when disabling spanning tree or when moving a port from a VLAN to another VLAN when spanning tree is disabled. If the switch is (re)booted with spanning tree configured as disabled, the proper address entry will be created on each of the ports.
Perform either of the following to correct this situation:
The following conditions have been corrected with the 2.2(1) version of the software release. In addition, all corrections applied to the 2.0(3) and 2.1(2) releases are included in this release.
CSCdj10909: NVRAM TFTP Download/Upload fails if a Catalyst 3200 is not first in the Stack
CSCdj11850: Changing ports between VLANs on a Catalyst 3000 series causes packet loss
CSCdj09537: Interoperability between Catalyst 3000 and 5000 with ISL; CAM gets confused
CSCdj12151: Broadcast Suppression Broken
CSCdj12152: ISL, Non-ISL Ports are numbered incorrectly
CSCdj12155: Trunking, Non-Trunking bounces if new VLAN is created
CSCdj15107: Connectivity over LANE stops for awhile then comes back.
Note: The fix for this anomaly is contained in v14 of the ATM firmware, not in the 2.2(2) image.
CSCdj16625: MAC filters block traffic to CPU
CSCdj02783: Stack port numbering incorrect if boxes swapped
CSCdj08257: High ping failure rate between Catalyst 3000 series and FORE ATM NIC
CSCdj15310: SSCOP problems between Catalyst 3000 series and LS1010
CSCdj14897: Catalyst 3000 (series) propagates VTP packets from STP blocked ports in VTP transparent mode
CSCdj18924: Address table - ping stopped working when trunk became static
CSCdj19374: ARP response was not sent over a trunk. STP was FWD but ASIC was BLK
CSCdj19472: Stack - box 2 does not agree with box 1's spanning tree topology
CSCdj19203: STP - Box 2 does not see box 1's ports due to ATM card init timing
CSCdi92430: RB can be confused by primary leaving/rejoining without notification
CSCdj13107: Broadcast packets should not be forwarded to CPU when IP is disabled
CSCdj17518: ISL trunking not passing Appletalk traffic
CSCdj21434: BRIDGE.MIB does not fully support Stack ports.
The following conditions have been corrected with the 2.2(2) version of the software release. In addition, all corrections applied to the 2.0(3), 2.1(2) and 2.2(1) releases are included in this release.
CSCdj14210: CDP failing to send packets on ports in other boxes in b2b stack
CSCdj21110: ifNumber reports incorrect value
CSCdj21434: BRIDGE.MIB does not fully support Stack ports
CSCdj24255: vlad: moving a port into a vlan, removes the vlan from the trunk
CSCdj24715: Cold-start traps do not work with spanning tree off
CSCdj25727: Download of ATM firmware V14 corrupts FLASH
CSCdj26552: Collision Counter Fields in 802.3 stats report incorrect info 4 100BT
CSCdj27570: Port assignment to VLAN unsuccessful
CSCdj27909: (Catalyst) 3000 fails to respond to SNMP
CSCdj28689: MIB ifIndex problems
CSCdj29292: DISL does not properly handle future DISL packet versions
CSCdj29384: LEC does not come up if VLAN present only on ATM
CSCdj29388: CPU entries not created for VLAN only on ATM trunks
CSCdj29681: Add ATM Info in ShowTech Support
CSCdj29908: dot1dTpFdbStatus object shows incorrect value
CSCdj30442: DISL sometimes thinks link is down when its not
CSCdj30498: RMON short-term history utilization is off by 6%
CSCdj30659: Cat3200 getting bogus values for Largest Number of active stations
CSCdj32455: Problems with system password length
CSCdj32957: ifDescr is missing for the default interface
CSCdj35024: console is very slow in a Stack with ATM traffic
CSCdj36000: Statistics - the largest number of stations is not reset.
CSCdj36118: ATM - Download ATM image fails when two ATM cards in a box.
CSCdj37474: Mcast/Bcast from trunk not delivered to VLAN ports
CSCdj37687: Memory corruption on telnets
For service and support for a product purchased from a reseller, contact the reseller. Resellers offer a wide variety of Cisco service and support programs, which are described in the section "Service and Support" in the information packet that shipped with your chassis.
For service and support for a product purchased directly from Cisco, use CCO.
CCO is Cisco Systems' primary, real-time support channel. SMARTnet customers and partners can self-register on CCO to obtain additional content and services.
Available 24 hours a day, 7 days a week, CCO provides a wealth of standard and value-added services to Cisco's customers and business partners. CCO services include product information, software updates, release notes, technical tips, the Bug Navigator, configuration notes, brochures, descriptions of service offerings, and download access to public and authorized files.
CCO serves a wide variety of users through two interfaces that are updated and enhanced simultaneously--a character-based version and a multimedia version that resides on the World Wide Web (WWW). The character-based CCO supports Zmodem, Kermit, Xmodem, FTP, and Internet e-mail, and is excellent for quick access to information over lower bandwidths. The WWW version of CCO provides richly formatted documents with photographs, figures, graphics, and video, as well as hyperlinks to related information.
You can access CCO in the following ways:
For a copy of CCO's Frequently Asked Questions (FAQ), contact cco-help@cisco.com. For additional information, contact cco-team@cisco.com.
Please use CCO to obtain general information about Cisco Systems, Cisco products, or upgrades. If CCO is not accessible, contact 800 553-6387, 408 526-7208, or cs-rep@cisco.com.
|