cc/td/doc/product/lan/cat3ks
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table of Contents

Catalyst 3000 Stack
Release Note: Expansion Modules

Catalyst 3000 Stack
Release Note: Expansion Modules

Supplement to DOC-CAT3000SUG (text part number 78-2438-01)

Introduction

This Release Note, Number 78-2876-01, provides specific information regarding the release of the Catalyst 3000 Stack expansion modules.

The following sections list:

Version 1.1.1 Software Release Notes

Version 1.1.1 (or later) software supports the following expansion modules:

3-port 10BaseF and 4-port 10BaseT Expansion Module Release Notes

The following sections describe certain known anomalies that are specific to the 3-port 10BaseF and the 4-port 10BaseT expansion modules.

STP Configuration Note

Manual port cost adjustment is necessary when changing expansion modules from 100Base to 10Base modules, or from 10Base to 100Base modules (a power cycle or reset will not automatically change the port cost value):

(See the Spanning Tree section in Chapter 7, "Console Configuration" in the Catalyst 3000 Stack User Guide for configuring STP.)

Sniffer Port

CRC errors may occur on a sniffer port that was configured by a management station using SNMP, if that port is a 3-port 10BaseF or a 4-port 10BaseT expansion module port.

If CRC errors occur on a sniffer port that was configured on a 3-port 10BaseF or a 4-port 10BaseT expansion module port by a management station using SNMP, use the console to reconfigure the port.

To configure a port using a console, enter the console Configuration screen and select the SwitchProbe menu. Select "SwitchProbe Port Number" and enter the number of the port that you want to monitor.

See Chapter 10, "Monitoring Port Activity with SwitchProbe" in the Catalyst 3000 Stack User Guide for a detailed explanation of monitoring a port with SwitchProbe.





hometocprevnextglossaryfeedbacksearchhelp
Copyright 1989-1997 © Cisco Systems Inc.