This appendix lists cables that have been tested and verified for use with the Catalyst 3000. It also includes minimum pin-out information, if you use a cable that is not listed, you must verify that the cables used in your installation are wired correctly.
This appendix covers the following topics:
10Base-T ports 1 through 15 on the Catalyst 3000 are always MDI-X, and port 16 can be set to MDI-X or MDI. Cabling these ports to different types of equipment will require a straight-through or a crossover cable.
A "straight-through" cable is used when connecting two ports that are not set to the same MDI mode or not set to the same MDI-X mode. 10Base-T ports 1 through 15 on the Catalyst 3000 are always MDI-X, and port 16 can be set to MDI-X. When connecting these MDI-X ports to ports that are MDI, such as PCs or servers, use a straight-through cable. A straight-through cable has each internal twisted pair of wires connected to the same pin number at each end. The twisted-pair wires must be twisted throughout the entire length of the cable. The wiring sequence must conform to AT&T 258A (not USOC). Figure A-1 shows the wiring diagram for a straight-through cable, and Table A-1, "10Base-T Cable Pin-Out" is a listing of the signals used on each pin.
Pins 1 and 2 must be a twisted pair.
Pins 3 and 6 must be a twisted pair.
Pins 4, 5, 7, and 8 are not used in this application, although they may be wired in the cable.
The following table lists the pin numbers and their respective signal names for a 10Base-T straight-through cable.
Pin | Signal | Note |
---|---|---|
1 | TX+ |
Pins 4, 5, 7, and 8 are not used.
|
2 | TX- | |
3 | RX+ | |
6 | RX- |
For cabling between two switches, the transmit and receive pairs must be reversed. You can do this in one of two ways:
1. Use a straight cable with one switch port set to MDI and the other set to MDI-X.
2. Use a crossover cable with both switch ports set to MDI or both ports set to MDI-X.
Figure A-2 shows the wiring diagram for a crossover cable.
Pins 1 and 2 at B, must be a twisted pair wired through to pins 6 and 3, respectively, at A.
Pins 3 and 6 at A, must be a twisted pair wired through to pins 2 and 1, respectively, at B.
Pins 4, 5, 7, and 8 on cable B are not used in this application, although they may be wired in the cable.
A short crossover cable can be used to adapt a straight-through twisted-pair cable for "cascading" switches through the twisted-pair ports.
The 100Base-TX expansion module network port is always MDI-X. Cabling to different types of equipment will require a straight-through or a crossover cable.
Transceiver end 15-pin Female | Switch end 15-pin Male | Signal |
---|---|---|
2 | 2 | Control In circuit A |
3 | 3 | Data Out circuit A |
4 | 4 | Data In circuit Shield (common drain) |
5 | 5 | Data In circuit A |
6 | 6 | Voltage common |
9 | 9 | Control In circuit B |
10 | 10 | Data Out circuit B |
12 | 12 | Data In circuit B |
13 | 13 | Voltage plus (+12 @ 500ma) |
For this connection, you can use:
Some longer cables may have all 15 pins wired. See the IEEE 802.3 standards document for definitions of the pins not shown here.
Cable Function | Port Type on Terminal, PC, or Modem | Standard Cable or Cable Solution |
---|---|---|
Connecting a terminal or PC to the console port with an EIA(RS)-232-C | 25-pin female | Attach a null modem adapter (Tandy Null Modem Adapter No. 26-1496 has been tested) to the console port. Then attach a straight-through modem cable to the null modem adapter. |
9-pin male | Use a Black Box PC/AT Serial Printer Cable (EVENBPC has been tested). OR: | |
Connecting a modem to the console port | 25-pin female or male port | Straight-through EIA-232-C modem cable (standard cable) |
* For these cables, the signals DTR (pin 20) and RTS (pin 4) must be on, or high, on your terminal or in your terminal emulation program. |
The Catalyst 3000 has a DB-9 console port that automatically detects baud rate. The default is 9600 baud; other supported baud rates are 1200, 2400, 4800, and 19200.
For a terminal connection, you use a null-modem cable or a straight cable with a null modem adapter attached.
For a modem connection, you can use a standard modem (straight) cable.
The following table and two figures detail pin assignment information for the cables you can use on the console port of the Catalyst 3000.
Pin | Function |
---|---|
1 | DCD |
2 | RXD |
3 | TXD |
4 | DTR |
5 | SIG GND |
6 | DSR |
7 | RTS |
8 | CTS |
9 | RI |
The following figures, (Figure A-3 and Figure A-4) detail pin assignment information for the cables you can use on the console port of the Catalyst 3000.
Posted: Fri Mar 3 15:49:52 PST 2000
Copyright 1989 - 2000©Cisco Systems Inc.