cc/td/doc/product/lan/cat3560/12220se1
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table Of Contents

Technical Specifications


Technical Specifications


This appendix lists the switch technical specifications in Table A-1 to Table A-8.

Table A-1 Technical Specifications for the Catalyst 3560-24PS Switch

Environmental Ranges

Operating temperature

32 to 113°F (0 to 45°C)

Storage temperature

-13 to 158°F (-25 to 70°C)

Relative humidity

10 to 85% (noncondensing)

Operating altitude

Up to 10,000 ft (3049 m)

Storage altitude

Up to 15,000 ft (4573 m)

Power Requirements

AC input voltage

100 to 240 VAC (autoranging)
5.5 A to 2.8 A, 50 to 60 Hz

DC input voltage for RPS 675

+ 12 V@7.5 A and - 48 V@7.8 A

Power consumption

485 W

Power dissipation

115 W, 393 BTUs per hour

Power rating

0.485 kVA

Power over Ethernet

15.4 W per port maximum, 370 W switch maximum

Physical Dimensions

Weight

11.3 lb (5.14 kg)

Dimensions (H x D x W)

1.73 x 11.81 x 17.5 in. (4.39 x 30 x 44.45 cm)


Table A-2 Specifications for the Catalyst 3560-48PS Switch 

Environmental Ranges

Operating temperature

32 to 113°F (0 to 45°C)

Storage temperature

-13 to 158°F (-25 to 70°C)

Relative humidity

10 to 85% (noncondensing)

Operating altitude

Up to 10,000 ft (3049 m)

Storage altitude

Up to 15,000 ft (4573 m)

Power Requirements

AC input voltage

100 to 240 VAC (autoranging)
5.5 to 2.8 A, 50 to 60 Hz

DC input voltages for RPS 675

+ 12 V@7.5 A and - 48 V@7.8 A

Power consumption

530 W

Power dissipation

160 W, 546 BTUs per hour

Power rating

0.53 kVA

Power over Ethernet

Range from 4 to 15.4 W per port, up to 370 W switch maximum

Physical Dimensions

Weight

13.2 lb (6 kg)

Dimensions (H x D x W)

1.73 x 14.85 x 17.5 in. (4.39 x 37.72 x 44.45 cm)


Table A-3 Specifications for the Catalyst 3560-24TS-S Switch 

Environmental Ranges

Operating temperature

32 to 113°F (0 to 45°C)

Storage temperature

-13 to 158°F (-25 to 70°C)

Relative humidity

10 to 85% (noncondensing)

Operating altitude

Up to 10,000 ft (3049 m)

Storage altitude

Up to 15,000 ft (4573 m)

Power Requirements

AC input voltage

100 to 240 VAC (autoranging) 450 to 190 mA, 50 to 60 Hz

DC input voltages for RPS 675

+ 12 V@ 5 A

Power consumption

45 W

Power dissipation

45 W, 154 BTUs per hour

Power rating

0.075 kV

Physical Dimensions

Weight

8.5 lb (3.9 kg)

Dimensions (H x D x W)

1.73 x 11.81 x 17.5 in. (4.39 x 30 x 44.45 cm)


Table A-4 Specifications for the Catalyst 3560-48TS-S Switch 

Environmental Ranges

Operating temperature

32 to 113°F (0 to 45°C)

Storage temperature

-13 to 158°F (-25 to 70°C)

Relative humidity

10 to 85% (noncondensing)

Operating altitude

Up to 10,000 ft (3049 m)

Storage altitude

Up to 15,000 ft (4573 m)

Power Requirements

AC input voltage

100 to 240 VAC (autoranging)
650 to 270 mA, 50 to 60 Hz

DC input voltages for RPS 675

+ 12 V@ 5 A

Power consumption

65 W

Power dissipation

65 W, 222 BTUs per hour

Power rating

0.110 kVA

Physical Dimensions

Weight

9.1 lb (4.1 kg)

Dimensions (H x D x W)

1.73 x 11.81 x 17.5 in. (4.39 x 30 x 44.45 cm)


Table A-5 Specifications for the Catalyst 3560G-24TS Switch 

Environmental Ranges

Operating temperature

32 to 113°F (0 to 45°C)

Storage temperature

-13 to 158°F (-25 to 70°C)

Relative humidity

10 to 85% (noncondensing)

Operating altitude

Up to 10,000 ft (3049 m)

Storage altitude

Up to 15,000 ft (4573 m)

Power Requirements

AC input voltage

100 to 240 VAC (autoranging)
1.5 to 3 A, 50 to 60 Hz

DC input voltages for RPS 675

+ 12 V@10.5 A

Power consumption

100 W

Power dissipation

100 W, 314 BTUs per hour

Power rating

0.10 kVA

Physical Dimensions

Weight

12 lb (5.44 kg)

Dimensions (H x D x W)

1.73 x 14.9 x 17.5 in. (4.39 x 37.8 x 44.45 cm)


Table A-6 Specifications for the Catalyst 3560G-24PS Switch 

Environmental Ranges

Operating temperature

32 to 113°F (0 to 45°C)

Storage temperature

-13 to 158°F (-25 to 70°C)

Relative humidity

10 to 85% (noncondensing)

Operating altitude

Up to 10,000 ft (3049 m)

Storage altitude

Up to 15,000 ft (4573 m)

Power Requirements

AC input voltage

100 to 240 VAC (autoranging)
4 to 8 A, 50 to 60 Hz

DC input voltages for RPS 675

+ 12 V@14 A and - 48 V@7.8 A

Power consumption

520 W

Power dissipation

170 W, 534 BTUs per hour

Power rating

0.52 kVA

Power over Ethernet

Range from 4 to 15.4 W per port, up to 370 W switch maximum

Physical Dimensions

Weight

13.5 lb (6.1 kg)

Dimensions (H x D x W)

1.73 x 14.9 x 17.5 in. (4.39 x 37.8 x 44.45 cm)


Table A-7 Specifications for the Catalyst 3560G-48TS Switch 

Environmental Ranges

Operating temperature

32 to 113°F (0 to 45°C)

Storage temperature

-13 to 158°F (-25 to 70°C)

Relative humidity

10 to 85% (noncondensing)

Operating altitude

Up to 10,000 ft (3049 m)

Storage altitude

Up to 15,000 ft (4573 m)

Power Requirements

AC input voltage

100 to 240 VAC (autoranging)
3 to 1.5 A, 50 to 60 Hz

DC input voltages for RPS 675

+ 12 V@17.5 A

Power consumption

160 W

Power dissipation

160 W, 500 BTUs per hour

Power rating

0.16 kVA

Physical Dimensions

Weight

14 lb (6.4 kg)

Dimensions (H x D x W)

1.73 x 16.1 x 17.5 in. (4.39 x 40.9 x 44.45 cm)


Table A-8 Specifications for the Catalyst 3560G-48PS Switch 

Environmental Ranges

Operating temperature

32 to 113°F (0 to 45°C)

Storage temperature

-13 to 158°F (-25 to 70°C)

Relative humidity

10 to 85% (noncondensing)

Operating altitude

Up to 10,000 ft (3049 m)

Storage altitude

Up to 15,000 ft (4573 m)

Power Requirements

AC input voltage

100 to 240 VAC (autoranging)
4 to 8 A, 50 to 60 Hz

DC input voltages for RPS 675

+ 12 V@14 A and - 48 V@7.8 A

Power consumption

560 W

Power dissipation

220 W, 690 BTUs per hour

Power rating

0.56 kVA

Power over Ethernet

Range from 4 to 15.4 W per port, up to 370 W switch maximum

Physical Dimensions

Weight

15.5 lb (7.03 kg)

Dimensions (H x D x W)

1.73 x 16.1 x 17.5 in. (4.39 x 40.9 x 44.45 cm)



hometocprevnextglossaryfeedbacksearchhelp

Posted: Fri Apr 8 22:27:10 PDT 2005
All contents are Copyright © 1992--2005 Cisco Systems, Inc. All rights reserved.
Important Notices and Privacy Statement.