cc/td/doc/product/lan/cat3200
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table of Contents

Monitoring Port Activity with Application Software

Monitoring Port Activity with Application Software

This chapter explains how to monitor a port on the Catalyst 3200 using:

The topics discussed are:
The topics discussed are:

SNMP Set-up

Follow these steps to use in-band management:

Step 1 Attach the Catalyst 3200 to the console and start a console session as described in Chapter 6, "Connecting a Network Management Console."

Step 2 Complete the IP Configuration menu.

Step 3 Complete the SNMP Configuration menu and following sub-menus:

Community String menu.


Trap Receiver menu.


The following sections describe the SNMP set-up menus.

IP Configuration

The IP Configuration menu sets the IP address, gateway address, subnet mask, and IP state.

The IP Address and Default Gateway must be in the same subnet address class--that is, Class A, Class B, or Class C. The system prevents you from entering values from different classes. If you do inadvertently enter an incorrect value, enter 0.0.0.0 in every field, then re-enter the correct values.

Refer to Chapter 7, "Console Configuration," for a complete description on how to configure the IP Configuration menu.

SNMP Configuration

Use the SNMP Configuration Menu to configure specific attributes related to SNMP.

SNMP Configuration Screen



Send Authentication Traps

Indicates whether SNMP should issue an authentication trap to Trap Receivers whenever an unauthorized request is detected.

Default: Yes

Community String Menu

Changes the community string table. The community string is the name associated with the Catalyst 3000 and a set of SNMP Managers. Entries in the table are saved across resets and power cycles.

Trap Receiver Menu

Displays table of managers to which traps are sent. Entries in the table are saved across resets and power cycles.

Community String Menu

Use the Community String menu to configure the community string for the Catalyst 3200. The community string is the name associated with the Catalyst 3200 and a set of SNMP managers allowed to manage it with the specified privilege level.




Note Text within the community string is Upper/Lower case sensitive.

Entries are displayed in the order in which they are encountered. There is a limit of 10 community strings.

Community String Table entries are saved when you select Return to Previous Menu. Entries are preserved across resets and power cycles.

Index

Sequential number of entries in the table.

Community Name

The specified privilege level of the assigned community.

Mode

Specific access privileges of the community.

Add Entry

Adds community string.

Delete Entry

Deletes community string.

Change Entry

Modifies community string and/or access mode.

Clear Table

Deletes all community strings.

Trap Receiver Menu

Trap Receiver Tables tell the Catalyst 3200 where to send traps. The table contains the IP address associated with an SNMP manager.



The Trap Receiver Table contains a maximum of 20 entries. It is displayed again each time the table changes. Each VLAN requires a separate entry.

Trap Receiver Table entries are saved when you select Return to Previous Menu. Entries are preserved across resets and power cycles.

IP Address

The IP address associated with an SNMP manager.

Community String

The specified privilege level.

VLAN

Specifies a list of VLANs in which the trap is sent out.

More

To view next page of table.

Add Entry

Adds a new entry to the trap receiver table.

Delete Entry

Deletes an entry from the trap receiver table.

Change Entry

Modifies an entry in the trap receiver table.

Clear Table

Deletes all table entries.

Zoom

To display a Trap receiver entry in detail.

Uses of the SwitchProbe Analyzer Port (SPAN)

The SPAN port, located on the front panel of the Catalyst 3200 Supervisor Engine, connects to probe devices such as protocol analyzers, RMON probes, and other Ethernet-compliant devices. This enables you to decode packet contents for troubleshooting or to analyze network characteristics. Using the SPAN port, you can monitor any one of the 10BaseT ports on the Catalyst 3200.

The SPAN port can not monitor the high-speed expansion module ports.

The SPAN port is used for monitoring only; it cannot be used to transmit data. Therefore, monitoring the Catalyst 3200 with an RMON probe requires the use of two ports: one to listen through the SPAN port and one to communicate with the SNMP station.

To monitor several Catalyst 3200 devices using a single monitoring device, connect each SPAN port to a hub, then connect the monitoring device to the hub. Do not connect any ports other than SPAN ports. Only one SPAN port may be active at once; disable all other SPAN ports by entering 0 in the SwitchProbe Port field of the SwitchProbe Configuration menu (see the section, Selecting the Port to Analyze, later in this chapter).

When traffic at a port that is being monitored by the SwitchProbe is very heavy (above 80 to 90%), the SwitchProbe (not the port) may drop some packets.

Selecting the Port to Analyze

You can select which port you want to analyze using either the network management console connected to the EIA RS-232 console port of the Catalyst 3200, or using an SNMP network management application such as the Cisco SwitchVision application or a Telnet session.

SwitchProbe Configuration Screen

Follow these steps to select the port to analyze:

Step 1 From the Main menu, select the Configuration menu, then select the SwitchProbe (Configuration) menu. The following screen appears:



Step 2 Complete the field for the port number on the screen as follows:

Use the arrow keys to highlight the SwitchProbe Port Number field and press RETURN. At the New Value: prompt, enter the number of the port you want to monitor (be sure the Monitor Link is enabled [up] on that port) or enter zero to disable the SwitchProbe function on the port.
The type of traffic that will be monitored. If the selected port is set for Half-Duplex communication, both Receive and Transmit traffic is monitored. If the selected port is set for Full-Duplex communication, you can monitor either Receive or Transmit traffic. To toggle between Receive or Transmit, select the field and press RETURN.

Step 3 Select Return to Previous Menu to accept the new settings.

Step 4 Begin monitoring port traffic using the probe equipment.


Note If you change the duplex mode of a port that is being monitored by the SwitchProbe Port, traffic on that port will no longer be seen by the SwitchProbe Port. You must reenter this menu and reconfigure the SwitchProbe Port to that port.

Using an RMON Application

Use the RMON Configuration Menu to establish communications with an RMON application.

Starting RMON

Use the following steps to start, stop, or configure an RMON application:

Step 1 Go to the Configuration menu and select RMON Configuration.

Step 2 From the RMON Configuration menu, highlight Enable RMON and press RETURN.

Step 3 At the prompt, select Yes or No.

Step 4 To add the community string, go to the Configuration menu and select the SNMP Configuration menu.

Step 5 From the SNMP Configuration menu, select the Community Strings menu.

Step 6 At the Community Strings menu:

Step 7 Select the Trap Receivers menu at the SNMP Configuration menu.

Step 8 At the Trap Receivers menu:

RMON Groups Supported

Ethernet Statistics (see the section on RMON Ethernet Statistics Counters).

History

Events

Alarms

RMON Requirements

The following lists the RMON requirements for a single Catalyst switch and a Stack of switches.

Stand alone Switch

A single switch can run with 4MB of memory with some restrictions. Do not increase the number of history buckets beyond 50. The number of VLANS (in the VTP VLAN Configuration) should be no more than 100.

Interface numbers 1-28 in Table 9-1.

Stacked Switches

The IP Controller switch (lowest number box in the Stack) must have 8MB of memory to run RMON on the Stack. Full configuration of all features is allowed.

It is recommend that switches with only 4MB not be used is a Stack. Otherwise, many restrictions apply. If the IP Controller switch has only 4MB, RMON statistics can be gathered only on that box. The number of VLANS (in the VTP VLAN Configuration) should be no more than 64, with ports assigned to no more than 14 VLANs. Do not increase the number of history buckets beyond 50. ISL trunks should not be installed in the IP Controller box.

Interface numbers 1-252. The interface numbers assigned to ports are listed in Table 9-1. They can also be calculated according to the following formula:

interface_number = (box_number - 1) * 32 + port_number


Table  9-1: Interface Numbers For Stack Ports
Port # Box 1 Box 2 Box 3 Box 4 Box 5 Box 6 Box 7 Box 8
1 1 33 65 97 129 161 193 225
2 2 34 66 98 130 162 194 226
3 3 35 67 99 131 163 195 227
4 4 36 68 100 132 164 196 228
5 5 37 69 101 133 165 197 229
6 6 38 70 102 134 166 198 230
7 7 39 71 103 135 167 199 231
8 8 40 72 104 136 168 200 232
9 9 41 73 105 137 169 201 233
10 10 42 74 106 138 170 202 234
11 11 43 75 107 139 171 203 235
12 12 44 76 108 140 172 204 236
13 13 45 77 109 141 173 205 237
14 14 46 78 110 142 174 206 238
15 15 47 79 111 143 175 207 239
16 16 48 80 112 144 176 208 240
17 17 49 81 113 145 177 209 241
18 18 50 82 114 146 178 210 242
19 19 51 83 115 147 179 211 243
20 20 52 84 116 148 180 212 244
21 21 53 85 117 149 181 213 245
22 22 54 86 118 150 182 214 246
23 23 55 87 119 151 183 215 247
24 24 56 88 120 152 184 216 248
25 25 57 89 121 153 185 217 249
26 26 58 90 122 154 186 218 250
27 27 59 91 123 155 187 219 251
28 28 60 92 124 156 188 220 252

Notes for Using TrafficDirector

These notes also apply to other RMON managers.

1 ) When setting up an agent on a Stack port, change the timeout from the default of 5 to at least 15 seconds. Retries may be left at the default value. This will prevent TrafficDirector from thinking the agent is not responding during Stack updates or address aging.

2 ) No RMON agent settings are saved by the switch. If a switch is rebooted, agents will need to be reinstalled by TrafficDirector.

3 ) If the IP Controller box is removed from the Stack, the agents will need to be reinstalled by TrafficDirector.

4 ) If a new box that is already running is added to a working Stack, but has a different enable/disable state setting for RMON, reboot the Stack. Otherwise, change the RMON state to the one that matches the working Stack, reboot the box, then add it to the Stack.

5 ) If a box leaves and then rejoins a Stack, all agents on that box must be reinstalled by TrafficDirector.

RMON Ethernet Statistics Counters

The following sections list the Statistics anomalies and the following table, Table 9-2, contains RMON Statistics definition differences.

Port counter resets

When the packet count (etherStatsPkts) wraps around at 4,294,967,295, the agent will think that the port's statistics have been cleared and will reset all the etherStats counters. If a network segment averages 5,000 pkts/sec, this counter will wrap around every 10 days.

Differences from RMON counter definitions.

The ISL ports have hardware support for accurate RMON counters, with one exception, etherStatsOversizePkts on ISL trunk ports. However, the other port types do not have special RMON counters, so the information may not be exactly according to the RMON counter definitions. Differences in the RMON definitions are listed in Table 9-2.


Table  9-2: RMON Definition Differences
Statistic Name Definition Differences
etherStatsDropEvents Total number of packets dropped by the monitor due to lack of resources. This is not necessarily the number of packets dropped, just the number of times this condition has been detected. For all ports, packets lost between the LMA and CPU buffers will not be counted. This can only happen under a long sustained, extremely heavy load of packets directed to the CPU.
etherStatsOctets Total number of octets (including those in bad packets) received on the network. This excludes framing bits but includes Frame Check Sum (FCS) octets. ISL and 100Mb ports are exact. 10Mb ports are missing octets from packets directed to the CPU, with errors, dropped due to buffer overflows, or limited to the local segment. 10Mb ports can only count octets of packets forwarded to other ports on the switch.
etherStatsPkts Total number of packets received, including multicast, broadcast, and bad packets. ISL ports are exact. All other ports include packets from other ports to this port that may have been dropped internally, a very infrequent event.
etherStatsBroadcastPkts Total number of good packets received directed to the broadcast address. This does not include Multicast packets. ISL ports are exact. All other ports are missing broadcast packets transmitted by this port and include broadcast packets with errors.
etherStatsMulticastPkts Total number of good packets that are received directed to a multicast address (excluding broadcast addresses). ISL ports are exact. All other ports are missing multicast packets transmitted by this port and include multicast packets with errors.
etherStatsCRCAlignErrors Total number of packets received with valid size with checksum or alignment errors. All ports are exact.
etherStatsUndersizePkts Total number of packets received with fewer than 64 octets, otherwise well-formed. ISL ports are exact. All other ports include short packets with errors, which are defined as etherStatsFragments.
etherStatsOversizePkts Total number of packets longer than 1,518 octets, otherwise well formed. ISL ports are exact in non-ISL mode but are reported as 0 when port is in ISL trunk mode. All other ports include long packets with errors, which are defined as etherStatsJabbers.
etherStatsFragments Total number of packets received with fewer than 64 octets, with checksum or alignment errors. ISL ports are exact. All other ports include short packets without errors, which are defined as etherStatsUndersizePkts.
etherStatsJabbers Total number of packets received longer than 1518 with checksum or alignment errors. ISL ports include all packets larger than 1536 bytes. All other ports include long packets without errors, which are defined as etherStatsOversizePkts.
etherStatsCollisions Best estimate of the total number of collisions on this ethernet segment. ISL ports are exact. All other ports count all packets that have collided at least once on this network segment, rather than counting the separate collisions.
etherStatsPkts60Octets
etherStatsPkts65to127Octets
etherStatsPkts128to255Octets
etherStatsPkts256to511Octets
etherStatsPkts512to1023Octets
etherStatsPkts1024to1518Octets
Total number of packets (including bad packets) received in this size range. ISL ports are exact. All other ports are 0. There is no way to get the packet size distribution without the appropriate hardware counters, because most packets are switched by the hardware.