|
Table Of Contents
Troubleshooting
The front-panel LEDs provide troubleshooting information about the switch. They show power-on self-test (POST) failures, port-connectivity problems, and overall switch performance. For a full description of the LEDs, see the "LEDs" section on page 2-10.
You can also get statistics from the browser interface, the command-line interface (CLI), the Cisco Intelligence Engine 2100 (IE2100) Series Configuration Registrar, or a Simple Network Management Protocol (SNMP) workstation. See the switch software configuration guide, the switch command reference, or the documentation that came with your IE2100 or SNMP application for details.
This chapter provides these topics for troubleshooting problems:
Understanding POST Results
After the power is connected, the switch automatically begins POST, a series of tests that verifies that the switch functions properly.
Note The uplink port status LEDs provide system and status information during POST. On the Catalyst 2955C-12 and 2955S-12, the uplink ports are labeled 13 and 14. On the Catalyst 2955T-12, the uplink ports are labeled 1 and 2.
Warning If you connect or disconnect the console cable with power applied to the switch or any device on the network, an electrical arc can occur. This could cause an explosion in hazardous location installations. Be sure that power is removed or the area is nonhazardous before proceeding.
To verify switch operation, perform POST on the switch in a nonhazardous location before installation. Statement 1065
When the Catalyst 2955C-12 and 2955S-12 begin POST:
•Uplink port 13 LED is amber.
•Uplink port 14 LED blinks green.
When the Catalyst 2955T-12 begins POST:
•Uplink port 1 LED is amber.
•Uplink port 2 LED blinks green.
If POST completes successfully on the Catalyst 2955C-12 and 2955S-12:
•Uplink port 13 LED turns green.
•Uplink port 14 LED goes off during the flash file system initialization.
If POST completes successfully on the Catalyst 2955T-12:
•Uplink port 1 LED turns green.
•Uplink port 2 LED goes off during the flash file system initialization.
If POST fails on the Catalyst 2955C-12 and 2955S-12:
•Uplink port 13 LED blinks amber.
•Uplink port 14 LED turns green.
If POST fails on the Catalyst 2955T-12:
•Uplink port 1 LED blinks amber.
•Uplink port 2 LED turns green.
Note The uplink port status LEDs provide system and status information during POST. On the Catalyst 2955T-12, the uplink ports are labeled 1 and 2. On the Catalyst 2955C-12 and 2955S-12, the uplink ports are labeled 13 and 14.
POST failures are usually fatal. Call Cisco Systems immediately if your switch does not pass POST. See the "Obtaining Technical Assistance" section on page xxviii.
Diagnosing Problems
Common switch problems fall into these categories:
•Poor performance
•No connectivity
•Corrupted software
Table 5-1 describes how to detect and solve these problems.
.
Table 5-1 Common Problems and Solutions
Symptom Possible Cause ResolutionPoor performance or excessive errors.
Duplex autonegotiation mismatch.
See the switch software configuration guide for information about identifying autonegotiation mismatches.
Cabling distance exceeded.
•Port statistics show excessive frame check sequence (FCS), late-collision, or alignment errors.
•See the switch software configuration guide for information about displaying port statistics.
•For 10BASE-T, 100BASE-TX, and 1000BASE-T connections:
–The distance between the port and the attached device exceeds 328 feet
(100 meters).
•Reduce cable length to within the recommended distances.
•For 100 and 1000 speed connections:
–Wrong cable type (not Cat 5) attached to device and switch
•Replace wrong cable type with Cat 5 cable.
–If the switch is attached to a repeater, the total distance between the two end stations exceeds the cabling guidelines.
•See your repeater documentation for cabling guidelines.
Bad adapter in attached device.
•Excessive errors found in port statistics.
•Run adapter card diagnostic utility.
Spanning Tree Protocol (STP) checking for possible loops.
Wait 30 seconds for port status LED to turn green.
No connectivity.
Incorrect or bad cable.
No link at both ends.
•A crossover cable was used when a straight-through was required, or vice-versa.
•For the correct pinouts and the proper application of crossover vs. straight-through cables, see the "Cable and Adapter Specifications" section on page B-5.
•The cable is wired incorrectly.
•Replace it with a tested good cable.
•STP checking for possible loops.
•Wait 30 seconds for port status LED to turn green.
Unreadable characters on the management console.
Incorrect baud rate.
Reset the terminal-emulation software to 9600 baud.
System LED (Uplink port status 13 LED) is amber, and all port LEDs are off.
Corrupted software.
Attach a monitor to the serial port to display the switch boot loader. For more information, see the switch software configuration guide.
System LED (Uplink port 13 LED) is amber.
•Fatal POST error detected.
•Contact Cisco Systems.
Posted: Mon Nov 15 05:39:24 PST 2004
All contents are Copyright © 1992--2004 Cisco Systems, Inc. All rights reserved.
Important Notices and Privacy Statement.