Console Serial Port
10BASE-T and 10/100BASE-T Ethernet Management Ports
Catalyst 2948G Switch Specifications
Catalyst 2948G-GE-TX Switch Specifications
Catalyst 2980G Switch Specifications

Specifications


This appendix provides management port and technical specifications for the Catalyst 2948G, 2948G-GE-TX, and 2980G switches.

Console Serial Port

The console serial port is an RJ-45 receptacle. Data terminal ready (DTR) and data set ready (DSR) handshake signals are supported on this port. The Request To Send (RTS) signal tracks the state of the Clear To Send (CTS) input. Table A-1 lists the console port pinouts.

Table A-1   Console Port Pinouts

Pin  Signal  Direction  Description 

1

 

RTS

 

output

 

request to send

 

2

DTR

output

data terminal ready

3

TXD

output

transmit data

4

GND

 

 

5

GND

 

 

6

RXD

input

receive data

7

DSR

input

data set ready

8

CTS

input

clear to send

10BASE-T and 10/100BASE-T Ethernet Management Ports

The Ethernet management port on each switch is an RJ-45 receptacle with a Link Status LED. Table A-2 lists the port pinouts.

Table A-2   10BASE-T Port Pinouts

Pin  Signal  Direction  Description 

1

 

RXD+

 

input

 

receive data

 

2

RXD-

input

receive data

3

TXD+

output

transmit data

4

unused

 

 

5

unused

 

 

6

TXD-

output

transmit data

7

unused

 

 

8

unused

 

 

Catalyst 2948G Switch Specifications

Table A-3 lists the Catalyst 2948G specifications.

Table A-3   Catalyst 2948G Switch Specifications

Item  Specification
Environmental

 

Temperature, ambient operating

32°F (0°C) to 104°F (40°C)

Temperature, ambient nonoperating and storage

-40°F (-40°C) to 167°F (75°C)

Humidity (RH), ambient (noncondensing) operating

10% to 90%

Environmental (continued)

Humidity (RH), ambient (noncondensing)
nonoperating and storage

5% to 95%

Altitude,
operating and nonoperating

0 to 65621.7 ft (0 to 2,000 m)

Switching Components

Backplane

12 Gbps full duplex

Microprocessor

150-MHz R5000 RISC-Y2K compliant

Memory

64 MB SDRAM, 12 MB Flash (onboard), 512 KB NVRAM, 8 MB synchronous SRAM, 256 bytes serial EEPROM

Physical Characteristics

Dimensions (H x W x D)

2.625 x 17.5 x 15 in. (6.6 x 44 x 38 cm)

Weight

13 lb. (5.9 kg)

AC Power

Power supply output

120 W

System power dissipation

189 W

System heat dissipation

645 BTU/hr.

AC input current

2.5 A maximum at 100 VAC
1.3 A maximum at @ 240 VAC

AC frequency

50 to 60 Hz

KVA rating

0.20

Airflow

Front side in, back side out

Standards Compliance

 

Compliance

CE Marking

Safety

UL1 1950, CSA2-C22.2 No. 950, EN360950, IEC4 60950

EMI5

CFR6 47, part 15 Class A (FCC), ICES7 003 Class A with UTP cables, EN55022 Class A with UTP cables, CISPR228 Class A with UTP cables, AS/NZS 3548 Class A with UTP cables, and VCCI9 Class A with UTP cables

EN55024, ETS 300 386

EN55022 Class B with FTP cables, CISPR22 Class B with FTP cables, AS/NZS 3548 Class B with FTP cables, and VCCI Class B with FTP cables

UL = Underwriters Laboratory

CSA = Canadian Standards Association

EN = European Norm

IEC = International Electrotechnical Commission

EMI = electromagnetic interference

CFR = Code of Federal Regulations

ICES = International Commerce Exchange Systems

CISPR = Comite International Special des Perturbation Radioelectriques

VCCI = Voluntary Control Council for Information Technology Equipment

Catalyst 2948G-GE-TX Switch Specifications

Table A-4 lists the Catalyst 2948G-GE-TX specifications.

Table A-4   Catalyst 2948G-GE-TX Switch Specifications

Item  Specification
Environmental

 

Temperature, ambient operating

32°F (0°C) to 104°F (45°C)

Temperature, ambient nonoperating and storage

-40°F (-40°C) to 167°F (75°C)

Humidity (RH), ambient (noncondensing) operating

10% to 90%

Humidity (RH), ambient (noncondensing)
nonoperating and storage

5% to 95%

Altitude,
operating and nonoperating

0 to 65621.7 ft (0 to 2,000 m)

Physical Characteristics

Dimensions (H x W x D)

1.75 x 17.5 x 17 in.

(4.45 x 44.5 x 43.1 cm)

Weight

13 lb. (5.9 kg)

AC Power

Power supply output

110 W

System power dissipation

130 W

System heat dissipation

445 BTU/hr.

AC input current

1.5 A maximum at 100 VAC
0.8 A maximum at 240 VAC

AC frequency

50 to 60 Hz

KVA rating

0.13

Airflow

Front side in, back side out

Standards Compliance

 

Compliance

CE Marking

Safety

UL1 1950, CSA2-C22.2 No. 950, EN360950, IEC4 60950

EMI5

CFR6 47, part 15 Class A (FCC), ICES7 003 Class A with UTP cables, EN55022 Class A with UTP cables, CISPR228 Class A with UTP cables, AS/NZS 3548 Class A with UTP cables, and VCCI9 Class A with UTP cables

EN55024, ETS 300 386

UL = Underwriters Laboratory

CSA = Canadian Standards Association

EN = European Norm

IEC = International Electrotechnical Commission

EMI = electromagnetic interference

CFR = Code of Federal Regulations

ICES = International Commerce Exchange Systems

CISPR = Comite International Special des Perturbation Radioelectriques

VCCI = Voluntary Control Council for Information Technology Equipment

Catalyst 2980G Switch Specifications

Table A-5 lists the Catalyst 2980G switch specifications.

Table A-5   Catalyst 2980G Switch Specifications

Item  Specification
Environmental

 

 

Temperature, ambient operating

32°F (0°C) to 104°F (40°C)

Temperature, ambient nonoperating and storage

-4°F (-20°C) to 149°F (65°C)

Humidity (RH), ambient (noncondensing) operating

10% to 90%

Humidity (RH), ambient (noncondensing) nonoperating and storage

5% to 95%

Altitude, operating and nonoperating

6561.7 ft. (0 to 2,000 m)

Switching Components

Backplane

12 Gbps full duplex

Microprocessor

150-MHz R5000 RISC-Y2K compliant

Memory

64 MB SDRAM, 16 MB Flash (onboard), 512 KB NVRAM, 8 MB synchronous SRAM, 256 bytes serial EEPROM

Physical Characteristics

Dimensions (H x W x D)

3.38 x 17.17 x 14.3 in. (8.6 x 43.6 x 36.3 cm)

Weight

13 lb. (5.9 kg)

AC Power

Power supply output

175 W (156 W on the Catalyst 2980G-A)

System power dissipation

270 W

System heat dissipation

950 BTU/hr. (670 BTU/hr. on the Catalyst 2980G-A)

AC input current

3 A maximum at 100 VAC
1 A maximum at 240 VAC

AC frequency

50 to 60 Hz

KVA rating

0.30

Airflow

Right side in, left side out

Standards Compliance

 

 

Compliance

CE Marking

Safety

UL1 1950, CSA2-C22.2 No. 950, EN360950, IEC4 60950

EMI5

FCC6 Class A (CFR7 47, part 15), ICES8-003 Class A, EN55022 Class A, CISPR229 Class A, AS/NZS 3548 Class A, and VCCI10 Class A with FTP11 cables

EN55022 Class B, CISPR22 Class B, AS/NZS 3548 Class B, and VCCI Class B with FTP cables

UL = Underwriters Laboratories

CSA = Canadian Standards Association

EN = European Norm

IEC = International Electrotechnical Commission

EMI = electromagnetic interference

FCC = Federal Communications Commission

CFR = Code of Federal Regulations

ICES = International Commerce Exchange Systems

CISPR = Comite International Special des Perturbation Radioelectriques

10 VCCI = Voluntary Control Council for Information Technology Equipment

11 FTP = foil-twisted pair