This appendix lists the pinouts for ports on the supervisor engine and other modules and for some of the interface cables that connect modules to the external network. All pins not specifically listed are not connected.
The following is a list of the signal summaries contained in this appendix:
The console port on the supervisor engine module is an EIA/TIA-232, data communications equipment (DCE), DB-25 receptacle. Both data set ready (DSR) and data carrier detect (DCD) are active when the system is running. The Request To Send (RTS) signal tracks the state of the Clear To Send (CTS) input. The console port does not support modem control or hardware flow control. Table C-1 lists the signals used on this port.
Pin | Signal | Direction | Description |
---|---|---|---|
1 | GND |
| Ground |
2 | RxD- | --> | Receive data - |
3 | TxD+ | <-- | Transmit Data + |
4 | CTS | <-- | Clear to send |
5 | RTS | --> | Return to send |
7 | GND |
| Ground |
8 | DTR | --> | Data terminal ready |
11 | +5V |
| + 5 Volts |
18 | GND |
| Ground |
20 | DCD | <-- | Data carrier detect |
Most Ethernet transceivers require a transceiver cable to connect an Ethernet transceiver to the supervisor engine module and Ethernet switching module Ethernet ports. Some unshielded twisted-pair (10BaseT) transceivers are compact enough to connect directly to the Ethernet module ports without impeding other connections. For descriptions of Ethernet transceivers, connectors, and cables, refer to the section "Ethernet Connection Equipment" in the chapter "Installation Overview."
Table C-2 lists the signals for the supervisor engine module 40-pin MII Fast Ethernet connector cable.
Pin | Signal | |
---|---|---|
1 | +5V | |
2 | MDIO | |
3 | MDC | |
4 | RxD<3> | |
5 | RxD<2> | |
6 | RxD<1> | |
7 | RxD<0> | |
8 | Rx_DV | |
9 | Rx_Clk | |
10 | Rx_Er | |
11 | Tx_Er | |
12 | Tx_Clk | |
13 | Tx_En | |
14 | TxD<0> | |
15 | TxD<1> | |
16 | TxD<2> | |
17 | TxD<3> | |
18 | Col | |
19 | CRS | |
20 | +5V | |
21 | +5V | |
22 | Common | |
23 | Common | |
24 | Common | |
25 | Common | |
26 | Common | |
27 | Common | |
28 | Common | |
29 | Common | |
30 | Common | |
31 | Common | |
32 | Common | |
33 | Common | |
34 | Common | |
35 | Common | |
36 | Common | |
37 | Common | |
38 | Common | |
39 | Common | |
40 | +5V |
Table C-3 lists the signals for the supervisor engine module RJ-45 Fast Ethernet 100BaseTX MDI X port.
Pin | Signal | Direction | Description |
---|---|---|---|
1 | RxD+ | <-- | Receive data + |
2 | RxD- | <-- | Receive data - |
3 | TxD+ | --> | Transmit Data + |
4 | NC |
| No connection |
5 | NC |
| No connection |
6 | TxD- | --> | Transmit Data - |
7 | NC |
| No connection |
8 | NC |
| No connection |
Table C-4 lists the signals for the Fast Ethernet switching module 100BaseTX 12 Port RJ-45 Fast Ethernet connector cable.
Table C-4 lists the RJ-45 connector port signals for the Fast Ethernet switching module 100BaseTX (12 port) and 10/100 Mbps Fast Ethernet switching module (12 port).
Signal | Pin | Direction | Description |
---|---|---|---|
RxD+ | 1 | <-- | Receive data + |
RxD- | 2 | <-- | Receive data - |
TxD+ | 3 | --> | Transmit Data + |
NC | 4 |
| No connection |
NC | 5 |
| No connection |
TxD- | 6 | --> | Transmit Data - |
NC | 7 |
| No connection |
NC | 8 |
| No connection |
|