|
If the Catalyst 1600 Token Ring switch does not work correctly when the installation is complete, use the procedures described in this appendix to diagnose the cause of the problem.
This chapter describes problems that may occur when you use TrueView Catalyst 1600 Manager to manage the Catalyst 1600. For information about using TrueView Catalyst 1600 Manager, refer to the TrueView Catalyst 1600 Manager User Guide.
Warning The Catalyst 1600 does not contain any user-serviceable components. Do not open the unit except when installing an option card according to proper instructions. When installing an option card, always observe the safety guidelines. |
If you cannot manage a Catalyst 1600 Token Ring switch using TrueView Catalyst 1600 Manager:
If a Token Ring switch port fails to open:
You can change the ring speed by using TrueView Catalyst 1600 Manager, or by connecting a terminal to the serial interface and using the set port ifspeed command (see the section "Read/Write Commands" in Chapter 4, "Serial Management").
You can change the port interface mode by using TrueView Catalyst 1600 Manager, or by connecting a terminal to the serial interface and using the set port ifmode command (see the section "Read/Write Commands" in Chapter 4 "Serial Management").
If there are problems forwarding source routed frames:
You can change the bridge number by using TrueView Catalyst 1600 Manager, or by connecting a terminal to the serial interface and using the show bridge characteristics command (see the section "Read-Only Commands" in Chapter 4 "Serial Management").
If two Catalyst 1600 devices are connected by their Token Ring switch ports, make sure the ring number is identical for both Token Ring ports.
You can set the ring number by using TrueView Catalyst 1600 Manager, or by connecting a terminal to the serial interface and using the set port segment command (see the section "Read/Write Commands" in Chapter 4 "Serial Management").
You can enable or disable source routing for the Catalyst 1600 and each port by using TrueView Catalyst 1600 Manager, or connecting a terminal to the serial interface and using the enable port srb command (see the section "Read/Write Commands" in Chapter 4 "Serial Management").
If there are problems forwarding source routed frames:
Before creating new virtual LANs, make sure you delete the existing virtual LANs that are causing problems forwarding source routing frames.
To check the station type for each Token Ring switch port, use TrueView Catalyst 1600 Manager.
|