There are several ways to troubleshoot problems associated with an EtherSwitch 1420 or EtherSwitch 1220 installation and performance. The LEDs on the front panel are the quickest way to evaluate the operation of the switch; statistics provided by the management console or SNMP management station can provide more details about the cause of connectivity and performance problems; the power-on self-test (POST) ensures that the switch is functioning properly at installation and when subsequently powered on.
Potential problems can be grouped into the following categories:
When the EtherSwitch 1420 or 1220 is first turned on and the switch begins its POST, the system and port LEDs are green. As each of the 13 tests is run, the port LEDs, starting with number 16, turn off. (Because there are only 13 tests, LEDs 15, 14, and 13 are unaffected.)
After the POST completes successfully, the port LEDs turn green, indicating that the switch is operational. If a test fails, the associated port LED stays off, and the system LED turns amber.
All POST failures except the real-time clock test (number 5) are fatal. If the real-time clock fails POST, the switch begins forwarding packets, but the system LED turns amber, and a POST-failure message appears on the console screen. Certain switch features, such as the bandwidth utilization meter, are lost if the real-time-clock test fails.
Your switch will not become operational if it fails POST. If the switch fails POST, contact Cisco Systems or your authorized reseller to return the switch.
Use Table 7-1 to identify your problem and resolve it. Note that those problems that refer to high-speed expansion slots and their inserted modules apply only to the
EtherSwitch 1420.
Symptom | Possible Cause | Resolution |
---|---|---|
Poor Performance or Excessive Errors | Incorrect Full-Duplex Settings for 100BaseT Connections
The full-duplex setting for modules is indicated by the full-duplex LED on the module front panel. Fixed 100BaseTX full-duplex port status is shown with the Mode button and the FDUP LED. Check the port's statistics: | |
|
Configure port for half duplex. | |
|
Configure the port for full duplex. | |
Cabling Distance Exceeded
Port statistics show excessive FCS, late-collision, or alignment errors. For 100BaseTX connections: | ||
|
Reduce the cable length to within the recommended distances. | |
|
See your 100BaseT repeater documentation for cabling guidelines. | |
For 10BaseT connections: The distance between the port and the attached device exceeds 100 meters. | Reduce the cable length to within the recommended distances. | |
Poor Performance or Excessive Errors | Bad Adapter in Attached Device
Excessive errors found in port statistics. |
Run adapter card diagnostic utility. |
No Connectivity | Incorrect or Bad Cable The following connectivity problems could generate no-link indications at either end:
|
See the "Connector Pinouts" section in Appendix A for the correct pinouts and the proper application of crossover vs. straight-through cables. |
|
Replace with a tested good one. | |
NetWare Network Numbers Misconstrued
If NetWare is used, the following message can appear on the server screen: Router configuration error detected. Node xxxxxxxx claims network zzzzzzzz should be yyyyyyyy. If you're using the IP protocol, try pinging the other end. |
All the nodes connected to ports in a single VLAN should all be assigned the same network number. | |
VLANs Misconfigured | ||
| Ensure the two nodes are connected to ports on the same VLAN. See the "VLAN Configuration" section in the "Out-of-Band Management" chapter to list ports of a VLAN. If you're using SNMP, see the "EtherSwitch 1420 and 1220 Enterprise-Specific MIB" section in the "In-Band Management" chapter for the MIB objects to use. | |
|
If there is a router, check the router configuration. Eliminate one of the two connections between the two VLANs. | |
Expansion Slot A or B LEDs Off | EtherSwitch 1420 Module Not Properly Installed | See the Troubleshooting chapter of the EtherSwitch 1420 Modules Installation Guide. |
System LED Amber; All Port LEDs Off | Corrupted Firmware | Attach a monitor to the serial port to display the diagnostic console. See the "Diagnostic Console Menu" section of this chapter for firmware upgrade instructions. |
Unable to Access Management Console |
|
Use the diagnostic console described in the "Diagnostic Console Menu" section of this chapter to reset the switch. Reset the modem parameters to their factory defaults with the diagnostic console. |
The diagnostic console is for those instances when the switch firmware has been corrupted or the present switch configuration prevents the firmware from executing properly. The Diagnostic Console Logon screen shown in Figure 7-1 is displayed when the firmware has been corrupted.
If you have defined a password for the switch, you are prompted for the password. If you have forgotten the password, you can obtain a factory-installed password by calling Cisco Systems and providing the Ethernet address displayed on the screen.
If no password has been defined, press Return to display the diagnostic console shown in Figure 7-2.
There can be times when you need the diagnostic console even though the firmware is valid. This could happen, for example, if a switch configuration prevents the firmware from executing properly and you cannot display the normal console.
Use the following procedure to override the normal firmware startup and immediately display the diagnostic console.
Step 1 Attach a monitor to the switch RS-232 port.
Step 2 Disconnect the power cord from the rear panel.
Step 3 Press the LED Mode button on the front panel and hold it in.
Step 4 While holding in the LED Mode button, reconnect the power cord.
Step 5 The Diagnostic Console Logon panel shown in Figure 7-1 appears.
Use this menu, shown in Figure 7-2, to troubleshoot firmware problems and then bring up the firmware as usual.
Operation firmware version: Status: | Validity of the current firmware. If the current image is not valid, option C on the diagnostic console is not displayed. |
Boot firmware version: | Write-protected part of the firmware that supports the diagnostic console. |
[C] Continue with standard system startup. Select this option after you have resolved the firmware problems with options [U] or [S]. It brings up the firmware as usual.
[U] Upgrade Operation Firmware. Select this option to initiate a firmware upgrade. This option works only with XMODEM and only uses the default RS-232 parameters:
Use the following procedure to upgrade the firmware with the XMODEM.
Step 1 Select option U.
Step 2 When the first XMODEM request appears, use the appropriate command to start the transfer.
Step 3 The diagnostic console is displayed when the upgrade is complete. Press C to restart the switch using the upgraded firmware.
[S] System Debug Interface. Select this option to display the System Debug Interface menu shown in Figure 7-3. You can use this menu to reset the management console RS-232 interface or the entire switch to the factory defaults.
Use this menu, shown in Figure 7-3, to reset the RS-232 interface or the entire switch to the factory defaults. You can also use the management console to perform these functions.
[G] Generic I/O. For Cisco personnel only.
[M] Memory (CPU) I/O. For Cisco personnel only.
[R] Return system to factory defaults. Use this option to return the switch to its factory settings. All static and dynamic addresses are removed, as is the IP address and all other configurations. Enter Y or N and press Return. The changes take effect the next time the switch is reset.
[R] Reset main console RS232 interface to 9600, 8, 1, N. Select this option if you have lost the management console connection because of an improper modem configuration. The next time the switch is reset, the default RS-232 configuration is used.
|