This appendix provides cabling guidelines, cabling configuration diagrams, part numbers, and port mapping tables for the following configurations:
Cisco 6130 with a POTS splitter configuration
Cisco 6130 without a POTS splitter configuration
Cisco used a standard telco color chart when designing the cables for the Cisco 6130 with NI-2 system connections. This appendix includes a standard telco color chart.
Warning Only trained and qualified personnel should be allowed to install, replace, or service this equipment.
Note For port mapping tables to build your own Cisco 6130 cables, see
Table B-12.
Table B-1 shows an overview of the cables used for each Cisco 6130 with NI-2 system configuration.
Table B-1 Cisco 6130 with NI-2 System Configuration and Cable Overview
You need to ensure that all cables are screwed in to the backplane and that the Champ connectors are tie wrapped. (See Figure B-1.)
Figure B-1 Cabling Guidelines
Cisco 6130 with a POTS Splitter Configuration Cables
In a Cisco 6130 with a POTS splitter configuration, use only designated cables to connect the Cisco 6130, the POTS splitter, and the MDF. This section provides tables and illustrations for the following cables:
Note Some chassis connectors in the cabling diagrams are not used because they are specific to one of the
other configurations of the Cisco 6130 with NI-2 system or because they are reserved for future use.
Cisco 6130 to Cisco 6120 Cables
You can use one-to-two cables to connect one Cisco 6130 to two Cisco 6120 chassis for systems using quad-port xTU-C line cards.
Table B-2 lists the backplane connectors and the part numbers for the one-to-two cables. In this configuration, 64 POTS splitter ports are used in each Cisco 6120, for a total of 128 ports.
Table B-2 Connectors and Part Numbers for One-to-Two CablesCisco 6130 to Two Cisco 6120 Chassis Connection
Backplane Connector
Cisco Part Number
Cisco 6130
First Cisco 6120 Connector
Second Cisco 6120 Connector
Kit
Subassembly
Backplane
Cable
Backplane
Cable
J39
J3
P3A
J3
P3B
CAB-MC128-PSC80
72-1767-011
J40
J1
P1A
J1
P1B
CAB-MC128-PSC80
72-1767-01
J41
J5
P5A
J5
P5B
CAB-MC128-PSC80
72-1767-01
J42
J4
P4A
J4
P4B
CAB-MC128-PSC80
72-1768-012
J43
J2
P2A
J2
P2B
CAB-MC128-PSC80
72-1769-013
J44
J6
P6A
J6
P6B
CAB-MC128-PSC80
72-1770-014
1This cable can be used for Cisco 6130 connectors J39, J40, and J41.
2This cable is specifically for Cisco 6130 connector J42.
3This cable is specifically for Cisco 6130 connector J43.
4This cable is specifically for Cisco 6130 connector J44.
Note When you use the one-to-two cable, see
Table B-8 for port
mapping information.
Tip If you use 64 POTS splitter ports, tie wrap the second Cisco 6120 connector to the rack. When you expand your system to 128 POTS splitter ports, the second Cisco 6120 connector will attach to a second Cisco 6120.
Figure B-3 shows the cabling between one Cisco 6130 and two Cisco 6120 chassis in which the cables listed in Table B-2 are used.
Figure B-3 Cisco 6130 to Two Cisco 6120 Chassis Cabling Diagram with One-to-Two Cables
Cisco 6130 to Third-Party POTS Splitter Cables
A third-party POTS splitter is compatible with the Cisco 6130. If you use a third-party POTS splitter, you need six one-to-one cables to connect the POTS splitter to the Cisco 6130 connectors J39 through J44. This one-to-one cable is not the same as the one-to-one cables used in previous configurations.
Use the one-to-one cable when you are connecting the Cisco 6130 to the third-party POTS splitter. Table B-3 lists the cable and associated part numbers.
Table B-3 Connectors and Part Numbers for One-to-One Cables for the Third-Party POTS Splitter
Backplane Connector
Cisco Part Number
Cisco 6130
Third-Party POTS Splitter
Kit
Subassembly
J39
xDSL 9-32
CAB-6121-1
72-1766-01
J40
xDSL 1-8 65-72
CAB-6121-1
72-1766-01
J41
xDSL 73-96
CAB-6121-1
72-1766-01
J42
xDSL 33-56
CAB-6121-1
72-1766-01
J43
xDSL 57-64 121-128
CAB-6121-1
72-1766-01
J44
xDSL 97-120
CAB-6121-1
72-1766-01
Note When you use the one-to-one cable, see
Table B-9 for port
mapping information.
Note If you are installing a Cisco 6130 with a POTS splitter configuration using the third-party POTS splitter,
install the Cisco components (excluding the POTS splitter) according to
"Installing a Cisco 6130 Without a
POTS Splitter Configuration." Refer to the appropriate vendor documentation for installation
procedures for the third-party POTS splitter.
POTS Splitter to MDF Cables
You can use the following cables to connect the POTS splitter (Cisco 6120 or third-party POTS splitter) to the MDF in a Cisco 6130 with a POTS splitter configuration:
One-to-one cablesUsed to connect the POTS splitter (Cisco 6120 or third-party POTS splitter) to the MDF.
Note Refer to the appropriate vendor documentation for cabling connectors and procedures for the
third-party POTS splitter.
Two-to-two cablesUsed to clearly associate the mapping between the wire pairs and the Cisco 6130 or Cisco 6120 ports. These cables attach to the Cisco 6120 MDF connections (J11 to J14) and the Cisco 6120 POTS connections (J7 to J10).
One-to-One Cables
You can use one-to-one cables to connect the Cisco 6120 to the MDF or POTS service connectors. Table B-4 lists the backplane connectors, the available cable lengths, and the part numbers for the one-to-one cables. Each cable has the same pinouts. The only difference between the four cables is the length. Use the length that works best for your configuration.
Table B-4 Connectors, Lengths, and Part Numbers for One-to-One CablesCisco 6120 to MDF or POTS Connections
Backplane Connector
Cisco Part Number
Cisco 6120
MDF Modem
Kit
Subassembly
MDF Connectors
J11, J12, J13, J14
P1 (modems 1 to 16), P3 (modems 33 to 48), P2 (modems 17 to 32), or P4 (modems 49 to 64)
CAB-61-015 50-ft cable
72-1599-01
CAB-61-016 150-ft cable
72-1598-01
CAB-61-017 75-ft cable
72-1597-01
CAB-61-018 175-ft cable
72-1596-01
POTS Connectors
J7, J8, J9, J10
P1 (modems 1 to 16), P3 (modems 33 to 48), P2 (modems 17 to 32), or P4 (modems 49 to 64)
Figure B-6 shows the cabling between the Cisco 6120 to the MDF in which the cables listed in Table B-4 are used.
Figure B-6 Cisco 6120 to MDF Cabling Diagram with One-to-One Cables
Figure B-7 shows the cabling between the Cisco 6120 to the POTS service connections in which the cables listed in Table B-4 are used.
Figure B-7 Cisco 6120 to POTS Service Cabling Diagram with One-to-One Cables
Note Refer to the appropriate vendor documentation for cabling connectors and procedures for the third-party
POTS splitter.
Two-to-Two Cables
To associate the Cisco 6120 MDF or POTS wire pairs and the Cisco 6130 modem ports, the two-to-two cable remaps the wire pairs from the Cisco 6120 MDF or POTS connectors to the Cisco 6120 connectors. You can use the two-to-two cable to
Connect the xDSL subscriber line connections on the Cisco 6120 (J11 to J14) to the MDF
Connect the voice lines on the Cisco 6120 (J7 to J10) to the voice-switching equipment that provides local POTS service
Table B-5 lists the backplane connectors and the part numbers for the two-to-two cables connecting the Cisco 6120 to the MDF in a Cisco 6130 with a POTS splitter configuration.
Table B-5 Connectors and Part Numbers for Two-to-Two CablesCisco 6120 to MDF Connections
Backplane Connector
Cisco Part Number
Cisco 6120
MDF Modem
Kit
Subassembly
xDSL Subscriber Line Connectors
J11, J12
P1 (modems 1 to 16) or P3 (modems 33 to 48)
CAB-PSC-80-REPIN
72-1716-01 (right cable)
J13, J14
P2 (modems 17 to 32) or P4 (modems 49 to 64)
CAB-PSC-80-REPIN
72-1772-01 (left cable)
Voice Line Connectors
J7, J9
P1 (modems 1 to 16) or P3 (modems 33 to 48)
CAB-PSC-80-REPIN
72-1716-01 (right cable)
J8, J10
P2 (modems 17 to 32) or P4 (modems 49 to 64)
CAB-PSC-80-REPIN
72-1772-01 (left cable)
Note When you use the two-to-two cable, see
Table B-10 for port
mapping information.
Figure B-9 shows the cabling between the xDSL subscriber line connectors on the Cisco 6120 and the MDF in which the cables listed in Table B-5 are used.
Figure B-9 Cisco 6120 to MDF Cabling Diagram with Two-to-Two CablesxDSL Subscriber Line Connectors
Figure B-10 shows the cabling between the voice lines on the Cisco 6120 and the voice-switching equipment that provides local POTS service. The cables listed in Table B-5 are used for the connection.
Figure B-10 Cisco 6120 to MDF Cabling Diagram with Two-to-Two CablesVoice Line Connectors
Cisco 6130 Without a POTS Splitter Configuration Cables
In a Cisco 6130 without a POTS splitter configuration, use only designated cables to connect the Cisco 6130 and the MDF.
Note Some chassis connectors in the cabling diagrams are not used because they are specific to one of the
other configurations of the Cisco 6130 with NI-2 system or because they are reserved for future use.
To associate the MDF wire pairs and the Cisco 6130 modem ports, the three-to-three cable remaps the wire pairs from the Cisco 6130 connectors to the MDF connectors. Use the cable in systems with quad-port xTU-C modules installed in the chassis. Table B-6 lists the backplane connectors and the part numbers for the three-to-three cables connecting the Cisco 6130 to the MDF in a Cisco 6130 without a POTS splitter configuration.
Table B-6 Connectors and Part Numbers for Three-to-Three CablesCisco 6130 to MDF Connections
Backplane Connector
Cisco Part Number
Cisco 6130
MDF
Kit
Subassembly
J39, J40, J41
P4 (slots 1 to 6), P5 (slots 7, 8, and 21 to 24), or P6 (slots 25 to 28)
CAB-MC128-MDF
72-1765-01 (right cable)
J42, J43, J44
P1 (slots 13 to 18), P2 (slots 19, 20, and 31 to 34), or P3 (slots 35 to 38)
CAB-MC128-MDF
72-1720-01 (left cable)
Note When you use the three-to-three cable, see
Table B-11 for port
mapping information.
Figure B-12 shows the cabling between the Cisco 6130 and the MDF in which the cables listed in Table B-6 are used.
Figure B-12 Cisco 6130 to MDF Cabling Diagram with Three-to-Three Cables
Intermixing Cables
Use intermixing cables when you want to configure half of the Cisco 6130 chassis with ADSL (Cisco 6130 with a POTS splitter configuration) and the other half of the chassis with SDSL (Cisco 6130 without a POTS splitter configuration).
Use CAB-128-mix cable set when you install quad-port flexi ATU-C line cards (4xflexis) in slots 1 through 8 and slots 21 through 28 and quad-port STU-C line cards (4xSDSLs) in slots 13 through 20 and slots 31 through 38. Table B-7 lists the backplane connectors and the part numbers for the CAB-128-mix cable set.
Table B-7 Connectors and Part Numbers for CAB-128-Mix Cable Set
Backplane Connector
Cisco Part Number
Cisco 6130
Third-Party POTS Splitter
MDF
Kit
Subassembly
J39
xDSL 9-32
CAB-128-mix
72-1766-01
J40
xDSL 1-8 65-72
CAB-128-mix
72-1766-01
J41
xDSL 73-96
CAB-128-mix
72-1766-01
J42, J43, J44
P1 (slots 13 to 18), P2 (slots 19, 20, and 31 to 34), or P3 (slots 35 to 38)
CAB-128-mix
72-1720-01 (left cable)
Note See the left side of Figure B-12
for the Cisco 6130 cable connections for the J42, J43, and J44 connectors. Refer to the
appropriate vendor documentation for cabling connectors and procedures for the third-party
POTS splitter.
Port Mapping Tables
This section provides port mapping tables which show the wire pair and chassis port assignments for the following configurations and cables:
Cisco 6130 with a POTS splitter configuration
Cisco 6130 without a POTS splitter configuration
Building your own Cisco 6130 cables
Cisco 6130 with a POTS Splitter Configuration Port Mapping Tables
Table B-8 maps the Cisco 6130 ports, the Cisco 6120 ports for two Cisco 6120 chassis, and the wire pairs when using the one-to-two cables (see Table B-2) for a Cisco 6130 with a POTS splitter configuration. The corresponding cable kit number is CAB-MC128-PSC80. You can use the one-to-two cables to connect one Cisco 6130 to two Cisco 6120 chassis for systems using quad-port ATU-C line cards.
Table B-8 Port Mapping for One-to-Two Cables in a Cisco 6130 with a POTS Splitter Configuration
Cisco 6130 Slot/Line
Cisco 6120 Slot/Line
Champ Pins
Cisco 6120 MDF/ POTS Connection
Cisco 6120 Chassis 1
Cisco 6120 Chassis 2
Tip
Ring
1/1
1/1
9
34
J11/J7
1/2
1/2
10
35
1/3
1/1
9
34
1/4
1/2
10
35
2/1
1/3
11
36
2/2
1/4
12
37
2/3
1/3
11
36
2/4
1/4
12
37
3/1
2/1
5
30
3/2
2/2
6
31
3/3
2/1
5
30
3/4
2/2
6
31
4/1
2/3
7
32
4/2
2/4
8
33
4/3
2/3
7
32
4/4
2/4
8
33
5/1
3/1
1
26
5/2
3/2
2
27
5/3
3/1
1
26
5/4
3/2
2
27
6/1
3/3
3
28
6/2
3/4
4
29
6/3
3/3
3
28
6/4
3/4
4
29
7/1
4/1
18
43
7/2
4/2
19
44
7/3
4/1
18
43
7/4
4/2
19
44
8/1
4/3
20
45
8/2
4/4
21
46
8/3
4/3
20
45
8/4
4/4
21
46
13/1
19/1
18
43
J14/J8
13/2
19/2
19
44
13/3
19/1
18
43
13/4
19/2
19
44
14/1
19/3
20
45
14/2
19/4
21
46
14/3
19/3
20
45
14/4
19/4
21
46
15/1
20/1
1
26
15/2
20/2
2
27
15/3
20/1
1
26
15/4
20/2
2
27
16/1
20/3
3
28
16/2
20/4
4
29
16/3
20/3
3
28
16/4
20/4
4
29
17/1
21/1
5
30
17/2
21/2
6
31
17/3
21/1
5
30
17/4
21/2
6
31
18/1
21/3
7
32
18/2
21/4
8
33
18/3
21/3
7
32
18/4
21/4
8
33
19/1
22/1
9
34
19/2
22/2
10
35
19/3
22/1
9
34
19/4
22/2
10
35
20/1
22/3
11
36
20/2
22/4
12
37
20/3
22/3
11
36
20/4
22/4
12
37
21/1
5/1
22
47
J11/J7
21/2
5/2
23
48
21/3
5/1
22
47
21/4
5/2
23
48
22/1
5/3
24
49
22/2
5/4
25
50
22/3
5/3
24
49
22/4
5/4
25
50
23/1
6/1
6
31
J12/J9
23/2
6/2
7
32
23/3
6/1
6
31
23/4
6/2
7
32
24/1
6/3
8
33
24/2
6/4
9
34
24/3
6/3
8
33
24/4
6/4
9
34
25/1
7/1
2
27
25/2
7/2
3
28
25/3
7/1
2
27
25/4
7/2
3
28
26/1
7/3
4
29
26/2
7/4
5
30
26/3
7/3
4
29
26/4
7/4
5
30
27/1
8/1
1
26
27/2
8/2
10
35
27/3
8/1
1
26
27/4
8/2
10
35
28/1
8/3
11
36
28/2
8/4
12
37
28/3
8/3
11
36
28/4
8/4
12
37
31/1
15/1
1
26
J13/J10
31/2
15/2
10
35
31/3
15/1
1
26
31/4
15/2
10
35
32/1
15/3
11
36
32/2
15/4
12
37
32/3
15/3
11
36
32/4
15/4
12
37
33/1
16/1
2
27
33/2
16/2
3
28
33/3
16/1
2
27
33/4
16/2
3
28
34/1
16/3
4
29
34/2
16/4
5
30
34/3
16/3
4
29
34/4
16/4
5
30
35/1
17/1
6
31
35/2
17/2
7
32
35/3
17/1
6
31
35/4
17/2
7
32
36/1
17/3
8
33
36/2
17/4
9
34
36/3
17/3
8
33
36/4
17/4
9
34
37/1
18/1
22
47
J14/J8
37/2
18/2
23
48
37/3
18/1
22
47
37/4
18/2
23
48
38/1
18/3
24
49
38/2
18/4
25
50
38/3
18/3
24
49
38/4
18/4
25
50
Table B-9 maps the Cisco 6130 ports, the POTS splitter ports, and the wire pairs when using the one-to-one cables (see Table B-3) when a third-party POTS splitter is installed in your configuration. The corresponding cable kit number is CAB-6121-1.
Table B-9 Port Mapping for One-to-One Cables with a Third-Party POTS Splitter
Cisco 6130 Slot/Line
POTS Splitter Slot/Line
Champ Pins
POTS Splitter Connection
Tip
Ring
1/1
1/1
26
1
Line 1 to 24 or POTS 1 to 24
1/2
1/2
27
2
1/3
1/3
28
3
1/4
1/4
29
4
2/1
1/5
30
5
2/2
1/6
31
6
2/3
1/7
32
7
2/4
1/8
33
8
3/1
2/1
34
9
3/2
2/2
35
10
3/3
2/3
36
11
3/4
2/4
37
12
4/1
2/5
38
13
4/2
2/6
39
14
4/3
2/7
40
15
4/4
2/8
41
16
5/1
3/1
42
17
5/2
3/2
43
18
5/3
3/3
44
19
5/4
3/4
45
20
6/1
3/5
46
21
6/2
3/6
47
22
6/3
3/7
48
23
6/4
3/8
49
24
7/1
4/1
26
1
Line 25 to 48 or POTS 25 to 48
7/2
4/2
27
2
7/3
4/3
28
3
7/4
4/4
29
4
8/1
4/5
30
5
8/2
4/6
31
6
8/3
4/7
32
7
8/4
4/8
33
8
13/1
5/1
34
9
13/2
5/2
35
10
13/3
5/3
36
11
13/4
5/4
37
12
14/1
5/5
38
13
14/2
5/6
39
14
14/3
5/7
40
15
14/4
5/8
41
16
15/1
6/1
42
17
15/2
6/2
43
18
15/3
6/3
44
19
15/4
6/4
45
20
16/1
6/5
46
21
16/2
6/6
47
22
16/3
6/7
48
23
16/4
6/8
49
24
17/1
7/1
26
1
Line 49 to 72 or POTS 49 to 72
17/2
7/2
27
2
17/3
7/3
28
3
17/4
7/4
29
4
18/1
7/5
30
5
18/2
7/6
31
6
18/3
7/7
32
7
18/4
7/8
33
8
19/1
8/1
34
9
19/2
8/2
35
10
19/3
8/3
36
11
19/4
8/4
37
12
20/1
8/5
38
13
20/2
8/6
39
14
20/3
8/7
40
15
20/4
8/8
41
16
21/1
9/1
42
17
21/2
9/2
43
18
21/3
9/3
44
19
21/4
9/4
45
20
22/1
9/5
46
21
22/2
9/6
47
22
22/3
9/7
48
23
22/4
9/8
49
24
23/1
10/1
26
1
Line 73 to 96 or POTS 73 to 96
23/2
10/2
27
2
23/3
10/3
28
3
23/4
10/4
29
4
24/1
10/5
30
5
24/2
10/6
31
6
24/3
10/7
32
7
24/4
10/8
33
8
25/1
11/1
34
9
25/2
11/2
35
10
25/3
11/3
36
11
25/4
11/4
37
12
26/1
11/5
38
13
26/2
11/6
39
14
26/3
11/7
40
15
26/4
11/8
41
16
27/1
12/1
42
17
27/2
12/2
43
18
27/3
12/3
44
19
27/4
12/4
45
20
28/1
12/5
46
21
28/2
12/6
47
22
28/3
12/7
48
23
28/4
12/8
49
24
31/1
13/1
26
1
Line 97 to 120 or POTS 97 to 120
31/2
13/2
27
2
31/3
13/3
28
3
31/4
13/4
29
4
32/1
13/5
30
5
32/2
13/6
31
6
32/3
13/7
32
7
32/4
13/8
33
8
33/1
14/1
34
9
33/2
14/2
35
10
33/3
14/3
36
11
33/4
14/4
37
12
34/1
14/5
38
13
34/2
14/6
39
14
34/3
14/7
40
15
34/4
14/8
41
16
35/1
15/1
42
17
35/2
15/2
43
18
35/3
15/3
44
19
35/4
15/4
45
20
36/1
15/5
46
21
36/2
15/6
47
22
36/3
15/7
48
23
36/4
15/8
49
24
37/1
16/1
26
1
Line 121 to 128 or POTS 121 to 128
37/2
16/2
27
2
37/3
16/3
28
3
37/4
16/4
29
4
38/1
16/5
30
5
38/2
16/6
31
6
38/3
16/7
32
7
38/4
16/8
33
8
Table B-10 maps the Cisco 6130 ports, the Cisco 6120 ports, and the wire pairs when using the two-to-two cables (see Table B-5) for a Cisco 6130 with a POTS splitter configuration. The corresponding cable kit number is CAB-PSC-80-REPIN.
You can use the two-to-two cables to clearly associate the mapping between the wire pairs and the Cisco 6130 and Cisco 6120 ports. These cables attach to the Cisco 6120 MDF connections (J11 to J14) and the Cisco 6120 POTS connections (J7 to J10) for systems using dual-port xTU-C line cards.
Table B-10 Port Mapping for Two-to-Two Cables in a Cisco 6130 with a POTS Splitter Configuration
Cisco 6130 Slot/Line
Cisco 6120 Slot/Line
Champ Pins
Cable Connector
Tip
Ring
1/1
1/1
1
26
P1
1/2
1/2
2
27
2/1
1/3
3
28
2/2
1/4
4
29
3/1
2/1
5
30
3/2
2/2
6
31
4/1
2/3
7
32
4/2
2/4
8
33
5/1
3/1
9
34
5/2
3/2
10
35
6/1
3/3
11
36
6/2
3/4
12
37
7/1
4/1
13
38
7/2
4/2
14
39
8/1
4/3
15
40
8/2
4/4
16
41
13/1
19/1
1
26
P2
13/2
19/2
2
27
14/1
19/3
3
28
14/2
19/4
4
29
15/1
20/1
5
30
15/2
20/2
6
31
16/1
20/3
7
32
16/2
20/4
8
33
17/1
21/1
9
34
17/2
21/2
10
35
18/1
21/3
11
36
18/2
21/4
12
37
19/1
22/1
13
38
19/2
22/2
14
39
20/1
22/3
15
40
20/2
22/4
16
41
21/1
5/1
1
26
P3
21/2
5/2
2
27
22/1
5/3
3
28
22/2
5/4
4
29
23/1
6/1
5
30
23/2
6/2
6
31
24/1
6/3
7
32
24/2
6/4
8
33
25/1
7/1
9
34
25/2
7/2
10
35
26/1
7/3
11
36
26/2
7/4
12
37
27/1
8/1
13
38
27/2
8/2
14
39
28/1
8/3
15
40
28/2
8/4
16
41
31/1
15/1
1
26
P4
31/2
15/2
2
27
32/1
15/3
3
28
32/2
15/4
4
29
33/1
16/1
5
30
33/2
16/2
6
31
34/1
16/3
7
32
34/2
16/4
8
33
35/1
17/1
9
34
35/2
17/2
10
35
36/1
17/3
11
36
36/2
17/4
12
37
37/1
18/1
13
38
37/2
18/2
14
39
38/1
18/3
15
40
38/2
18/4
16
41
Cisco 6130 Without a POTS Splitter Configuration Port Mapping Tables
Table B-11 maps the Cisco 6130 ports and the wire pairs when using the three-to-three cables (see Table B-6) for a Cisco 6130 without a POTS splitter configuration. The corresponding cable kit number is CAB-MC128-MDF. You can use the three-to-three cables to connect the Cisco 6130 to the MDF for systems using dual-port DMT-2 ATU-C or quad-port xTU-C line cards.
Table B-11 Port Mapping for Three-to-Three Cables in a Cisco 6130 Without a POTS Splitter Configuration
Cisco 6130 Slot/Line
Champ Pins
Cable Connector/ Cable Part Number
Tip
Ring
1/1
1
26
Connector P4/ Cable 72-1765-01
1/2
2
27
1/3
3
28
1/4
4
29
2/1
5
30
2/2
6
31
2/3
7
32
2/4
8
33
3/1
9
34
3/2
10
35
3/3
11
36
3/4
12
37
4/1
13
38
4/2
14
39
4/3
15
40
4/4
16
41
5/1
17
42
5/2
18
43
5/3
19
44
5/4
20
45
6/1
21
46
6/2
22
47
6/3
23
48
6/4
24
49
7/1
1
26
Connector P5/ Cable 72-1765-01
7/2
2
27
7/3
3
28
7/4
4
29
8/1
5
30
8/2
6
31
8/3
7
32
8/4
8
33
13/1
1
26
Connector P1/ Cable 72-1720-01
13/2
2
27
13/3
3
28
13/4
4
29
14/1
5
30
14/2
6
31
14/3
7
32
14/4
8
33
15/1
9
34
15/2
10
35
15/3
11
36
15/4
12
37
16/1
13
38
16/2
14
39
16/3
15
40
16/4
16
41
17/1
17
42
17/2
18
43
17/3
19
44
17/4
20
45
18/1
21
46
18/2
22
47
18/3
23
48
18/4
24
49
19/1
1
26
Connector P2/ Cable 72-1720-01
19/2
2
27
19/3
3
28
19/4
4
29
20/1
5
30
20/2
6
31
20/3
7
32
20/4
8
33
21/1
9
34
Connector P5/ Cable 72-1765-01
21/2
10
35
21/3
11
36
21/4
12
37
22/1
13
38
22/2
14
39
22/3
15
40
22/4
16
41
23/1
17
42
23/2
18
43
23/3
19
44
23/4
20
45
24/1
21
46
24/2
22
47
24/3
23
48
24/4
24
49
25/1
1
26
Connector P6/ Cable 72-1765-01
25/2
2
27
25/3
3
28
25/4
4
29
26/1
5
30
26/2
6
31
26/3
7
32
26/4
8
33
27/1
9
34
27/2
10
35
27/3
11
36
27/4
12
37
28/1
13
38
28/2
14
39
28/3
15
40
28/4
16
41
31/1
9
34
Connector P2/ Cable 72-1720-01
31/2
10
35
31/3
11
36
31/4
12
37
32/1
13
38
32/2
14
39
32/3
15
40
32/4
16
41
33/1
17
42
33/2
18
43
33/3
19
44
33/4
20
45
34/1
21
46
34/2
22
47
34/3
23
48
34/4
24
49
35/1
1
26
Connector P3/ Cable 72-1720-01
35/2
2
27
35/3
3
28
35/4
4
29
36/1
5
30
36/2
6
31
36/3
7
32
36/4
8
33
37/1
9
34
37/2
10
35
37/3
11
36
37/4
12
37
38/1
13
38
38/2
14
39
38/3
15
40
38/4
16
41
Port Mapping Table for Building Cisco 6130 Cables
Table B-12 provides the Champ pins and Cisco 6130 port mapping information needed to build your own chassis cables.
Table B-12 Port Mapping for Building Cisco 6130 Cables
Connector
Champ Pins
Cisco 6130 Slot/Line
Tip
Ring
J39
xDSL
Slots 3 through 8
(pins 25 and 50 are not used)
1
2
6/1
3
4
6/2
5
6
6/3
7
8
6/4
9
10
7/1
11
12
7/2
13
14
7/3
15
16
7/4
17
18
8/1
19
20
8/2
21
22
8/3
23
24
8/4
26
27
5/1
28
29
5/2
30
31
5/3
32
33
5/4
34
35
4/1
36
37
4/2
38
39
4/3
40
41
4/4
42
43
3/1
44
45
3/2
46
47
3/3
48
49
3/4
J40
xDSL
Slots 1, 2, 21, and 22
(pins 9 through 25 are not used)
1
2
22/1
3
4
22/2
5
6
22/3
7
8
22/4
26
27
21/1
28
29
21/2
30
31
21/3
32
33
21/4
34
35
2/1
36
37
2/2
38
39
2/3
40
41
2/4
42
43
1/1
44
45
1/2
46
47
1/3
48
49
1/4
J41
xDSL
Slots 23 through 23
(pins 25 and 50 are not used)
1
2
26/1
3
4
26/2
5
6
26/3
7
8
26/4
9
10
27/1
11
12
27/2
13
14
27/3
15
16
27/4
17
18
28/1
19
20
28/2
21
22
28/3
23
24
28/4
26
27
25/1
28
29
25/2
30
31
25/3
32
33
25/4
34
35
24/1
36
37
24/2
38
39
24/3
40
41
24/4
42
43
23/1
44
45
23/2
46
47
23/3
48
49
23/4
J42
xDSL
Slots 13 through 18
(pins 25 and 50 are not used)
1
2
17/1
3
4
17/2
5
6
17/3
7
8
17/4
9
10
18/1
11
12
18/2
13
14
18/3
15
16
18/4
17
18
13/1
19
20
13/2
21
22
13/3
23
24
13/4
26
27
16/1
28
29
16/2
30
31
16/3
32
33
16/4
34
35
15/1
36
37
15/2
38
39
15/3
40
41
15/4
42
43
14/1
44
45
14/2
46
47
14/3
48
49
14/4
J43
xDSL
Slots 19, 20, 37, and 38
(pins 9 through 25 and 50 are not used)
1
2
20/1
3
4
20/2
5
6
20/3
7
8
20/4
26
27
19/1
28
29
19/2
30
31
19/3
32
33
19/4
34
35
38/1
36
37
38/2
38
39
38/3
40
41
38/4
42
43
37/1
44
45
37/2
46
47
37/3
48
49
37/4
J44
xDSL
Slots 31 through 36
(pins 25 and 50 are not used)
1
2
35/1
3
4
35/2
5
6
35/3
7
8
35/4
9
10
36/1
11
12
36/2
13
14
36/3
15
16
36/4
17
18
31/1
19
20
31/2
21
22
31/3
23
24
31/4
26
27
34/1
28
29
34/2
30
31
34/3
32
33
34/4
34
35
33/1
36
37
33/2
38
39
33/3
40
41
33/4
42
43
32/1
44
45
32/2
46
47
32/3
48
49
32/4
Standard Telco Color Chart
In designing the cables for the Cisco 6130 with NI-2 system connections, Cisco used a standard telco color chart. Table B-13 lists the colors used for the Cisco 6130 with NI-2 system cables.