DS3 Subtending I/O Card FRU Installation and Replacement Notes

DS3 Subtending I/O Card FRU Installation and Replacement Notes

Product Number: 6100-ST-IO-3-DS3=

This document provides information about installing and replacing the Cisco 6100 Series system DS3 subtending I/O card. The DS3 subtending I/O card is a field-replaceable unit (FRU) and is installed on a multiplexer chassis (MC) backplane in a subtended network configuration.


Note Older versions of the system I/O card, the DS3 subtending I/O card, or the DS3 subtend host module (STM) cannot be mixed with the newer versions. The system I/O card (version 6100-SYS-IO-3=), the DS3 subtending I/O card (version 6100-ST-IO-3-DS3=) and the DS3 STM (version 6100-ST-3-DS3=) are compatible with each other. If you mix older versions with newer versions, the hardware components will not work properly.

If you need to replace all three hardware components at the same time, follow the removal and replacement procedures provided in the DS3 Retrofit Kit Release Notes located on the World Wide Web at http://www.cisco.com/univercd/cc/td/doc/product/dsl_prod/c6100/index.htm.

1. Contents

This document includes the following sections:

2. Subtended Network Configuration Overview

A subtended network configuration

The term subtending refers to the host MC, and subtended refers to the downstream MC in a subtended network.

Figure 1 shows a subtending tree. The subtending host MC at the top of the subtending tree connects directly to the ATM switch. You can have two subtended node MCs connected to the first subtending host MC located at the top of the subtending tree. One or both of these subtended node MCs can also become a subtending host MC and therefore have one or two subtended node MCs connected to them.


Figure 1: Subtended Cisco 6100 Series System Network


You can subtend an MC to three tiers, with up to six MCs, all connecting through one subtending host MC to the ATM backbone (see Figure 1).

In Figure 2, the DS3 subtend host module (STM) is installed in slot 9 of the subtending host MC. A network interface (NI) module is located in slot 10. If you have

Figure 2 shows a subtending host MC and a subtended node MC with corresponding slot number assignments.


Figure 2: Subtending Host and Subtended Node MC Slot Assignments


All MCs have a system I/O card installed on the MC backplane. In addition to the system I/O card, a DS3 subtending I/O card is installed on the subtending host MC backplane.

3. DS3 Subtending I/O Card Overview

The DS3 subtending I/O card has two sets of DS3 75-ohm coaxial DS3 Bayonet-Neill-Concelman (BNC) connectors. Each set consists of a transmit and a receive connector. There are four jumpers that are already installed on the DS3 subtending I/O card. Use the jumpers to connect the DS3 BNC shield to the chassis ground. Figure 3 shows the DS3 BNC connectors and DS3 jumpers on the DS3 subtending I/O card.


Figure 3: DS3 Subtending I/O Card Connections


In a subtended network configuration, the DS3 subtending I/O card is attached to MC connector J48, a 96-pin DIN connector. Figure 4 shows the location of the DS3 subtending I/O card in relation to the system I/O card on the MC backplane.


Figure 4: System I/O Card and DS3 Subtending I/O Card Locations


You can install a DS3 subtending I/O card on

4. DS3 Subtending I/O Card Cabling

Coaxial connections for cabling are located on the system I/O card and the DS3 subtending I/O card. The transmit and receive DS3 BNC connectors on the DS3 subtending I/O card are connected to the transmit and receive DS3 BNC connectors on the system I/O card (see Figure 5). Refer to the Cisco 6100 Series User Guide for cabling the system I/O card in a version of the Cisco 6100 Series system that is earlier than Release 2.4.0.


Figure 5: Cabling for Subtended Network Configuration



Note The system I/O card and DS3 subtending I/O card coaxial cables are not provided by Cisco Systems, Inc.

5. Installation Prerequisites

This section describes hardware requirements and lists the parts and tools used to install the DS3 subtending I/O card.

5.1 Hardware Requirements

The DS3 subtending I/O card is not a stand-alone product. In order for a DS3 subtending I/O card to work properly on a subtending host MC, you must install both a system I/O card and DS3 STM.


Note The system I/O card is installed on all MC backplanes.

5.2 Part and Tool Requirements

To install or replace the DS3 subtending I/O card, you need the following parts and tools:

6. General Safety Precautions and Installation Guidelines

This section covers the following topics:

6.1 General Safety Precautions

Before working on the equipment, be aware of standard safety practices and the hazards involved in working with electrical circuitry to prevent accidents. Adhere to the following cautions and warnings for safe and hazard-free installation.


Note To see translations of the warnings that appear in this publication, refer to the Regulatory Compliance and Safety Information for the Cisco 6100 Series System document.
Caution Proper ESD protection is required whenever you handle Cisco DSLAM equipment. Installation and maintenance personnel should be properly grounded using ground straps to eliminate the risk of ESD damage to the equipment. Modules are subject to ESD damage whenever they are removed from the chassis.
Caution Be careful when you remove the standoff screws and reinsert the screws into the screw holes on the backplane so that the backplane circuitry does not become damaged.
Caution If the modules are installed when you apply power to the system, you could damage the modules and the chassis.
Caution If fuses are already installed in the fuse and alarm panel, remove them. You can replace the fuses after the DS3 subtending I/O card is installed. Do not power up the system while you install and connect the DS3 subtending I/O card.
Warning There is the danger of explosion if the battery is replaced incorrectly. Replace the battery only with the same or equivalent type recommended by the manufacturer. Dispose of used batteries according to the manufacturer's instructions.
Warning Use copper conductors only.
Warning The DS3 ports are not intended to be connected to cables that run outside the building where it is installed. For any connections outside the building, the DS3 ports must be connected to a network termination unit (NTU). NTU devices should comply with appropriate national safety standards such as UL 1950, CSA 950, EN 60950, IEC 950, and AS 3260.
Warning Do not reach into a vacant slot or chassis while you install or remove a module or a fan. Exposed circuitry could constitute an energy hazard.
Warning Ethernet cables must be shielded when used in a central office environment.
Warning An exposed wire lead from a DC-input power source can conduct harmful levels of electricity. Be sure that no exposed portion of the DC-input power source wire extends from the terminal block plug.
Warning Incorrect connection of this or connected equipment to a general purpose outlet could result in a hazardous situation.
Warning Read the installation instructions before you connect the system to its power source.
Warning Only trained and qualified personnel should be allowed to install, replace, or service
this equipment.
Warning Do not work on the system or connect or disconnect cables during periods of lightning activity.
Warning This unit has more than one power supply connection; all connections must be removed completely to completely remove power from the unit.
Warning To reduce the risk of fire, use only No. 26 AWG or larger telecommunication line cord.
Warning To prevent the system from overheating, do not operate it in an area that exceeds the maximum recommended ambient temperature of 104°F (40°C).
Warning Secure all power cabling when installing this unit to avoid disturbing field-wiring connections.
Warning The power supply circuitry for the equipment can constitute an energy hazard. Before you install or replace the equipment, remove all jewelry (including rings, necklaces, and watches). Metal objects can come into contact with exposed power supply wiring or circuitry inside the DSLAM equipment. This could cause the metal objects to heat up and cause serious burns or weld the metal object to the equipment.
Warning Ultimate disposal of this product should be handled according to all national laws and regulations.
Warning This unit is intended for installation in restricted access areas. A restricted access area is where access can only be gained by service personnel through the use of a special tool, lock and key, or other means of security, and is controlled by the authority responsible for the location
Warning Connect the unit only to DC power source that complies with the Safety Extra-Low Voltage (SELV) requirements in IEC 60950 based safety standards.
Warning This product requires short-circuit (overcurrent) protection, to be provided as part of the building installation. Install only in accordance with national and local wiring regulations.
Warning Care must be given to connecting units to the supply circuit so that wiring is not overloaded.
Warning During this procedure, wear grounding wrist straps to avoid ESD damage to the card. Do not directly touch the backplane with your hand or any metal tool, or you could shock yourself.

6.2 Installation and Replacement Suggestions

The following are recommended installation and replacement practices:

Any card that is only partially connected to the backplane can disrupt system operation.

7. Installing the DS3 Subtending I/O Card

Use the procedures in this section to install and cable the DS3 subtending I/O card.

Caution Proper ESD protection is required whenever you handle Cisco DSLAM equipment. Installation and maintenance personnel should be properly grounded, using ground straps, to eliminate the risk of ESD damage to the equipment. Modules are subject to ESD damage whenever they are removed from the chassis.

Use the following steps to install the DS3 subtending I/O card:

Step 1   Remove the optional rear door, if your system has one.

Step 2   Open the MC front door.

Step 3   Pull all of the modules away from the MC backplane connection.

Step 4   Pull all of the modules away from the line concentration chassis (LCC) backplane connection.

Step 5   Pull all of the modules away from the POTS splitter chassis (PSC) backplane connection:

Step 6   Remove the fuses from the fuse and alarm panel. By removing the fuses, the system is not powered while you install and connect the DS3 subtending I/O card.

Step 7   Locate the two backplane screws that are above and below the MC connector J48 on a subtending host MC backplane. Use a Phillips-head screwdriver to remove the two backplane screws. Keep these backplane screws for use when you install the plastic ESD shield.

Figure 6 shows Step 7 through Step 10.


Figure 6: DS3 Subtending I/O Card Installation


Step 8   Use a one-quarter inch socket driver or wrench to screw two standoff screws into the locations formerly occupied by the two screws you removed in Step 6. Tighten the standoff screws using the one-quarter inch socket driver or wrench.

Caution Be careful when you remove the standoff screws and reinsert the screws into the screw holes on the backplane so that the backplane circuitry does not become damaged.

Step 9   Position and align the holes on the DS3 subtending I/O card over the two standoff screws and gently press the DS3 subtending I/O card into the MC connector J48 on the subtending host MC backplane.

Step 10   Use a one-quarter inch socket driver or wrench to screw two additional standoff screws into the screw holes in the DS3 subtending I/O card and into the original standoff screws added in Step 8. Tighten the standoff screws using the one-quarter inch socket driver or wrench.

Step 11   Attach one end of a coaxial cable (type 734A, type 735A, or equivalent) to the transmit DS3 BNC connector (TX1) for the DS3 subtending I/O card on the subtending host MC backplane. Figure 7 shows cabling for a subtended network configuration.


Figure 7: Cabling for Subtended Network Configuration


Step 12   Add ferrites to the coaxial cables that you use to cable the DS3 subtending I/O card to the system I/O card to reduce the radiation/EMI susceptibility to high frequency noise between 30 and 200 MHz. Use either the ferrites shipped with the DS3 NI module or ferrites that yield an impedance greater than 200 ohms +/- 20 percent at 100 MHz.

If you are using


Figure 8: Thick Coaxial Cable Through Ferrite



Figure 9: Thin Coaxial Cable Through Ferrite


Step 13   Attach a ferrite as close as possible to the remaining end of the cable (see Figure 8 or Figure 9 for ferrite installation). Tie wrap the cable directly behind the ferrite.

Step 14   Attach the end of the cable used in Step 13 to the receive DS3 BNC connector (RX) for the system I/O card on the subtended node MC backplane.

Step 15   Attach one end of a cable to the receive DS3 BNC connector (RX1) for the DS3 subtending I/O card on the subtending host MC backplane.

Step 16   Attach the ferrite as close as possible to the receive DS3 BNC connector (RX1) on the DS3 subtending I/O card (see Figure 8 or Figure 9 for ferrite installation). Tie wrap the cable directly behind the ferrite.

Step 17   Attach a ferrite as close as possible to the remaining end of the cable (see Figure 8 or Figure 9 for ferrite installation). Tie wrap the cable directly behind the ferrite.

Step 18   Attach the end of the cable used in Step 17 to the transmit DS3 BNC connector (TX) for the system I/O card on the subtended node MC backplane.

Step 19   Tie wrap the transmit and receive cables coming from the DS3 subtending I/O card where the cables meet after coming from the ferrites and every 1 foot thereafter for a total of 15 feet, as shown in Figure 10.


Figure 10: Ferrite Close to DS3 BNC Connectors on DS3 Subtending I/O Card


Step 20   Tie wrap the transmit and receive cables coming from the system I/O card where the cables meet after coming from the ferrites and every 1 foot thereafter for a total of 15 feet, as shown in Figure 11.


Figure 11: Ferrites Close to DS3 BNC Connectors on System I/O Card


Step 21   Install the plastic ESD shield over the DS3 subtending I/O card using the following steps:


Figure 12: Plastic ESD Shield Installation


Caution If the modules are installed when you apply power to the system, you could damage the modules and the chassis.

Step 22   Reinsert the fuses in the fuse and alarm panel. When you reinsert the fuses, the system powers on.

Step 23   Reseat all of the modules in the MC, LCC, and PSC. It is important that you accomplish each step completely before moving on to the next step.

Step 24   Verify that the MC front door is attached to the MC and closed to achieve NEBS compliance. For more information on NEBS requirements, refer to the Regulatory Compliance and Safety Information for the Cisco 6100 Series System document.

Step 25   Close the optional rear door using the following steps:

8. Removing and Replacing the DS3 Subtending I/O Card

The following sections describe how to remove and replace or install a DS3 subtending I/O card.

8.1 Removing a DS3 Subtending I/O Card

Caution Proper ESD protection is required whenever you handle Cisco DSLAM equipment. Installation and maintenance personnel should be properly grounded using ground straps to eliminate the risk of ESD damage to the equipment. Modules are subject to ESD damage whenever they are removed from the chassis.

Use the following steps to remove a DS3 subtending I/O card from the MC backplane:


Step 1   Remove the optional rear door, if your system has one.

Step 2   Open the MC front door.

Step 3   Pull all of the modules away from the MC backplane connection.

Step 4   Pull all of the modules away from the LCC backplane connection.

Step 5   Pull all of the modules away from the PSC backplane connection.

Step 6   Remove the fuses from the fuse and alarm panel. By removing the fuses, the system is not powered while you install and connect the DS3 subtending I/O card.

Step 7   Remove the coaxial cables from the four DS3 BNC connectors (TX1, RX1, TX2, and RX2) on the DS3 subtending I/O card.

Step 8   Use a Phillips-head screwdriver to remove the two backplane screws that hold the plastic ESD shield over the DS3 subtending I/O card. Keep these backplane screws and the plastic ESD shield for use when you replace the DS3 subtending I/O card.

Step 9   Use a one-quarter inch socket driver or wrench to remove the two additional standoff screws that are attached to the DS3 subtending I/O card.

Step 10   Lift and disconnect the DS3 subtending I/O card from connector J48, a 96-pin DIN connector on the subtending host MC backplane. Figure 13 shows the DS3 subtending I/O card removal.


Figure 13: DS3 Subtending I/O Card Removal


8.2 Replacing a DS3 Subtending I/O Card

Caution Proper ESD protection is required whenever you handle Cisco DSLAM equipment. Installation and maintenance personnel should be properly grounded using ground straps to eliminate the risk of ESD damage to the equipment. Modules are subject to ESD damage whenever they are removed from the chassis.

Use the following steps to replace a DS3 subtending I/O card on a subtending host MC backplane:


Note Before you replace a DS3 subtending I/O card, please complete all of the steps in the "Removing a DS3 Subtending I/O Card" section.

Step 1   Locate the two standoff screws that are above and below the MC connector J48. Tighten the standoff screws using a one-quarter inch socket driver or wrench.

Step 2   Position and align the holes on the DS3 subtending I/O card over the two standoff screws and gently press the DS3 subtending I/O card into the MC connector J48 on the subtending host MC backplane.

Figure 14 shows the DS3 subtending I/O card replacement procedures.


Figure 14: DS3 Subtending I/O Card Replacement


Step 3   Use a one-quarter inch socket driver or wrench to screw two additional standoff screws into the screw holes in the DS3 subtending I/O card and into the original standoff screws on the MC backplane. Tighten the standoff screws using a one-quarter inch socket driver or wrench.

Step 4   Locate the cable coming from the transmit DS3 BNC connector (TX) for the system I/O card on the subtended node MC.

Step 5   Attach the cable from Step 4 to the receive DS3 BNC connector (RX1) for the DS3 subtending I/O card on the subtending host MC.

Step 6   Locate the cable coming from the receive DS3 BNC connector (RX) for the system I/O card on the subtended node MC.

Step 7   Attach the cable from Step 6 to the transmit DS3 BNC connector (TX1) for the DS3 subtending I/O card on the subtending host MC.

Figure 15 shows cabling from a DS3 subtending I/O card to a system I/O card.


Figure 15: Cabling for a DS3 Subtending I/O Card and a System I/O Card


Step 8   Install the plastic ESD shield over the DS3 subtending I/O card using the following steps:


Figure 16: Plastic ESD Shield Installation


Caution If the modules are installed when you apply power to the system, you could damage the modules and the chassis.

Step 9   Reinsert the fuses in the fuse and alarm panel. When you reinsert the fuses, the system powers on.

Step 10   Reseat all of the modules in the MC, LCC, and PSC. It is important that you accomplish each step completely before moving on to the next step.

Step 11   Verify that the MC front door is attached to the MC and closed to achieve NEBS compliance. For more information on NEBS requirements, refer to the Regulatory Compliance and Safety Information for the Cisco 6100 Series System document.

Step 12   Close the optional rear door using the following steps:

9. Standards and Certifications

Table 1 lists the DS3 subtending I/O card standards and certifications.


Table 1: Standards and Certifications
Category Description

NEBS Level 3

Bellcore GR-63-CORE, GR-1089-CORE

EMI

FCC Part 15, Class A

Safety

UL 1950, 3rd Edition

10. Related Documentation

The following sections list the CO and customer premises equipment (CPE) publications that relate to the Cisco DSL product family.

10.1 CO Publications

A complete list of all released Cisco 6100 Series system with NI-1 related documentation is available on the World Wide Web at http://www.cisco.com/univercd/cc/td/doc/product/dsl_prod/c6100/index.htm.

The following ViewRunner management software is used to provision and manage the Cisco 6100 Series system with NI-1. A complete list of all released ViewRunner documentation is available on the Word Wide Web.

10.2 CPE Publications

The Cisco CPE, also known as the Cisco 600 Series, is part of the Cisco end-to-end DSL product family. CPE comprises modems and routers at the customer site primarily used by home office and corporate LAN personnel. Most CPE uses the Cisco Broadband Operating System (CBOS) as its operating system. CBOS provides a comprehensive command set and web interface that allow you to configure your Cisco CPE modem or router.

A complete list of all released Cisco 600 Series documentation is available on the World Wide Web at http://www.cisco.com/univercd/cc/td/doc/product/dsl_prod/c600s/index.htm.

11. Cisco Connection Online

Cisco Connection Online (CCO) is Cisco Systems' primary, real-time support channel. Maintenance customers and partners can self-register on CCO to obtain additional information and services.

Available 24 hours a day, 7 days a week, CCO provides a wealth of standard and value-added services to Cisco's customers and business partners. CCO services include product information, product documentation, software updates, release notes, technical tips, the Bug Navigator, configuration notes, brochures, descriptions of service offerings, and download access to public and authorized files.

CCO serves a wide variety of users through two interfaces that are updated and enhanced simultaneously: a character-based version and a multimedia version that resides on the World Wide Web (WWW). The character-based CCO supports Zmodem, Kermit, Xmodem, FTP, and Internet e-mail, and it is excellent for quick access to information over lower bandwidths. The WWW version of CCO provides richly formatted documents with photographs, figures, graphics, and video, as well as hyperlinks to related information.

You can access CCO in the following ways:

For a copy of CCO's Frequently Asked Questions (FAQ), contact cco-help@cisco.com. For additional information, contact cco-team@cisco.com.


Note If you are a network administrator and need personal technical assistance with a Cisco product that is under warranty or covered by a maintenance contract, contact Cisco's Technical Assistance Center (TAC) at 800 553-2447, 408 526-7209, or tac@cisco.com. To obtain general information about Cisco Systems, Cisco products, or upgrades, contact 800 553-6387, 408 526-7208, or cs-rep@cisco.com.

12. Documentation CD-ROM

Cisco documentation and additional literature are available in a CD-ROM package, which ships with your product. The Documentation CD-ROM, a member of the Cisco Connection Family, is updated monthly. Therefore, it might be more current than printed documentation. To order additional copies of the Documentation CD-ROM, contact your local sales representative or call customer service. The CD-ROM package is available as a single package or as an annual subscription. You can also access Cisco documentation on the World Wide Web at http://www.cisco.com, http://www-china.cisco.com, or http://www-europe.cisco.com.

If you are reading Cisco product documentation on the World Wide Web, you can submit comments electronically. Click Feedback in the toolbar and select Documentation. After you complete the form, click Submit to send it to Cisco. We appreciate your comments.