Table A-1 lists specifications for the Cisco IAD1101 integrated access device.
Description | Specifications |
---|---|
Physical Characteristics of the Chassis | Dimensions: (HxWxD) 1.75 x 17.5 x 12 in. Weight: 11 lb |
Environmental | Operating Temperature: 0 to +40oC Operating Humidity: 10 to 85% noncondensing |
Storage Environmental | Storage Temperature: -20 to +65oC Storage Humidity: 5 to 95% noncondensing |
AC input voltage range | 100 to 120 VAC (60Hz) |
AC current rating (input) | Maximum current: 1.5A |
DC input voltage ranges | -42.5 to -56 VDC, 5A fused |
DC current rating (input) | Maximum current: 1.2A |
Table A-2 lists regulatory approval requirements for the Cisco IAD1101.
Regulatory Requirement | Approval Agency |
---|---|
Safety | UL1950, CSA C22.2 |
Emission | FCC Part 15, Class B |
Telcordia Technologies (formerly Bellcore) | GR-303, GR-308, TR-57, GR-253, GR-63, SR-3580, GR-1089, GR-436, GR-1244, TR-487, ANSI T1.101 |
NEBS | NEBS compliant |
A single battery box contains four 12 VDC batteries connected in series, generating -48 VDC. The resulting current is used for backup power to the Cisco IAD1101 chassis.
Physical Characteristics | Dimensions: (HxWxD) 8.8 x 8.3 x 6.2 in. Weight: 49 lb |
Nominal Voltage | 12V |
Rated Capacity | 12 Ah |
Internal Resistance | 14 Mohm |
Maximum short-duration discharge current | 180A |
Maximum charging current | 600 mA |
Charging voltage | Standby: 13.5 to 13.8 V (-20V/oC) Cyclic: 14.4 to 15.0 V (-30V/oC) |
Battery backup time | Maximum 8 hr (24 FXS circuits at 18 CCS) |
Battery charge time | 24 hr |