A.1 Hardware Specifications

This section details the specifications for the following hardware components:

A.1.1 Cisco 6260 Chassis

Table A-1 lists the hardware specifications of the Cisco 6260 system.


Table A-1: Cisco 6260 Hardware Specifications
Specification Description

Dimensions

13.43 RUs—23.5 in. x 17.5 in. x 11.0 in. (59.7 cm x 44.5 cm x 28.0 cm)

Weight

Empty—Approximately 37.5 lb (17.0 kg)
Loaded—Approximately 80 lb (36.3 kg)

Network interface

ATM OC-3c (single- or multimode fiber), ATM E3, ATM E1

Note   When the DS3/2DS3 NI-2 card is installed in the Cisco 6260 chassis, it assumes E3 functionality.

ADSL interface

DMT—Up to 8.032 Mbps downstream/864 kbps upstream
G.lite—Up to 1.536 Mbps downstream/512 kbps upstream

SDSL interface

2B1Q—Up to 1168 kbps upstream and downstream

SHDSL interface

TC-PAM1

Craft interface

Console terminal connection on the NI-2 card

Management access

  • RJ-45 interface for craft alarm discovery

  • RJ-45 Ethernet

  • ATM in-band management

External alarm contacts

Single dry contact alarm input (NO)

Power requirements

  • -40.5 VDC to -75 VDC

Note   See "Preparing for Installation," for detailed power requirements.

CO operating requirements

Temperature


Altitude


Humidity

Operating shock

Nonoperating shock

41º to 104ºF (5º to 40ºC)—Operating
23º to 131ºF (-5º to 55ºC)—Short-term operating

0 to 10,000 feet (0 to 3048 meters)—Operating
0 to 30,000 feet (0 to 9144 meters)—Nonoperating

5 to 95% (noncondensing)

5 to 500 Hz, 0.5 gravity (0.1 octave per minute)

5 to 100 Hz, 1 gravity (0.1 octave per minute);
100 to 500 Hz, 1.5 gravities (0.2 octave per minute);
500 to 1000 Hz, 1.5 gravities (0.2 octave per minute)

Maximum heat dissipation for a fully loaded chassis

4097 BTUs/hour

Acoustic noise

60 dB at normal fan speed

Subtending

  • One OC-3c connection on the OC-3c/OC-3c NI-2 card

  • Two E3 connections on the E3 I/O module when used in conjunction with the DS3/2DS3 NI-2 card

  • Up to seven E1 connections on the E1 I/O module when used in conjunction with the DS3+T1/E1 IMA NI-2 card

1TC-PAM = trellis coded pulse amplitude modulation

A.1.2 Quad-Port DMT ATU-C Line Card

Table A-2 lists the specifications for the 4xDMT.


Table A-2: Quad-Port DMT ATU-C Line Card Specifications
Specification Description

Standards supported

ITU G.dmt
ITU G.lite
ANSI T1.413 Issue 2

External interfaces

4 (no connectors on card)

Data rates (per port)

Upstream: Up to 864 kbps
Downstream: Up to 8.032 Mbps

Internal hardware

  • 18 MHz AM186ESLV.2 CPU

  • AD20msp918 DMT modem chipset

  • 128 KB SRAM

  • 256 K x 16 boot flash

  • 2 KB serial EEPROM

Dimensions

Height: 6.07 in. (15.42 cm)
Depth: 8.50 in. (21.59 cm)
Width: 0.88 in. (2.24 cm)

Weight

0.875 lb (0.4 kg)

Power consumption

16.5W

Minimum software and network management requirement

Cisco IOS—Release 12.0(5)DA

CDM1—Release 3.0 (optional)

1CDM = Cisco DSL Manager

A.1.3 Quad-Port DMT over ISDN Line Card

Table A-3 lists the specifications for the 4xDMT over ISDN.


Table A-3: Quad-Port DMT Over ISDN Line Card Specifications
Specification Description

Data rates (per port)

Upstream: 32 to 864 kbps in increments of 32 kbps

Downstream: 32 to 8032 kbps in increments of 32 kbps

Symmetrical: Matches upstream and downstream rates

Internal hardware

  • 18 MHz AM186ESLV.2 CPU

  • AD20msp918 DMT modem chipset

  • 128 KB SRAM

  • 256 K x 16 boot flash

  • 2 KB serial EEPROM

Dimensions

Height: 6.07 in. (15.42 cm)

Depth: 8.50 in. (21.59 cm)

Width: 0.88 in. (2.24 cm)

Weight

0.875 lb (0.4 kg)

Power consumption

16.5W

Minimum software and network management requirement

Cisco IOS—Release 12.1(3)DA

CDM—Release 3.2 (optional)

A.1.4 Quad-Port Flexi ATU-C Line Card

Table A-4 lists the specifications for the 4xflexi.


Table A-4: Quad-Port Flexi ATU-C Line Card Specifications
Specification Description

Standards supported

ITU G.dmt (G.992.1)
ANSI T1.413

Power consumption

17.5W

Data rates (per port)

Downstream: 8.032 Mbps
Upstream: 864 kbps

External interfaces

4 (no connectors on card)

Internal hardware

AMD 186-based 3.3V 18-MHz CPU

128 KB SRAM

512 K flash

Dimensions

Height: 6.07 in. (15.42 cm)

Depth: 8.50 in. (21.59 cm)

Width: 0.88 in. (2.24 cm)

Weight

0.875 lb (0.4 kg)

Minimum software and network management requirement

Cisco IOS—Release 12.1(4)DA

CDM—Release 3.2 (optional)

A.1.5 Quad-Port STU-C Line Card

Table A-5 lists the specifications for the 4xSDSL.


Table A-5: Quad-Port STU-C Line Card Specifications
Specification Description

Standards supported

ITU G.991.1

External interfaces

4 (no connectors on card)

Data rates (per port)

Downstream: 1168 kbps
Upstream: 1168 kbps

Line encoding

2B1Q

Internal hardware

AMD 186-based 3.3V 18-MHz CPU

128 KB SRAM

512 K flash

Dimensions

Height: 6.07 in. (15.42 cm)
Depth: 8.50 in. (21.59 cm)
Width: 0.88 in. (2.24 cm)

Weight

0.875 lb (0.4 kg)

Power consumption

9W

Minimum software and network management requirement

Cisco IOS—Release 12.1(4)DA

CDM—Release 3.0 (optional)

A.1.6 Octal-Port DMT ATU-C Line Card

Table A-6 lists the specifications for the 8xDMT.


Table A-6: Octal-Port DMT ATU-C Line Card Specifications
Specification Description

Standards supported

  • ANSI T1.413-Issue 2, Category 1 only

  • ANSI T1.413-Issue 2, Annex F (Reduced NEXT)

  • Universal Test & Operations PHY for ATM, Level 2; A standard for transport of ATM cells over a 16-bit parallel data bus. Refer to the ATM Forum document af-phy-0039.000.

  • ITU G.992.1, Annex A (G.dmt)

  • ITU G.992.2. (G.lite)

  • ITU G.994.1. (G.hs)

External interfaces

8 (no connectors on card)

Data rates (per port)

Upstream: Up to 1024 kbps
Downstream: Up to 8.064 Mbps

Internal hardware

  • 40 MHz Motorola MPC850 microprocessor

  • 8 MB SDRAM

  • 1 Mb boot flash

  • 1 KB serial EEPROM

Dimensions

Height: 6.07 in. (15.42 cm)
Depth: 8.50 in. (21.59 cm)
Width: 0.88 in. (2.24 cm)

Weight

0.875 lb (0.4 kg)

Power consumption

24W

Minimum software and network management requirement

Cisco IOS—Release 12.1(6)DA

CDM—Release 3.3(2)

A.1.7 Octal-Port DMT ATU-C Over ISDN Line Card

Table A-7 lists the specifications for the 8xDMT over ISDN.


Table A-7: Octal-Port DMT ATU-C Over ISDN Line Card Specifications
Specification Description

Standards supported

  • Universal Test & Operations PHY for ATM, Level 2; a standard for transport of ATM cells over a 16-bit parallel data bus. Refer to the ATM Forum document af-phy-0039.000.

  • ITU G.992.1 (G.dmt), Annex B/ETSI

  • ITU G.994.1 (G.hs)

  • ETSI TS 101 388 V.1.1.1/(draft) TM6(98)12

  • TS102 080 v1.3.2 -Support for 2B1Q and 4B3T ISDN

External interfaces

8 (no connectors on card)

Data rates (per port)

Upstream: Up to 1024 kbps
Downstream: Up to 7.616 Mbps

Framing modes

Overhead Framing Mode 3 supported

Internal hardware

  • 40 MHz Motorola MPC850 microprocessor

  • 8 MB SDRAM

  • 8 Mb boot flash

  • 1 KB serial EEPROM

Dimensions

Height: 6.07 in. (15.42 cm)
Depth: 8.62 in. (21.89 cm)
Width: 0.88 in. (2.24 cm)

Weight

0.875 lb (0.4 kg)

Power consumption

24W

Minimum software and network management requirement

Cisco IOS—Release 12.2(5) DA

A.1.8 Octal-Port G.SHDSL SHTU-C Line Card

Table A-8 lists the specifications for the 8xG.SHDSL.


Table A-8: Octal-port G.SHDSL SHTU-C Line Card Specifications
Specification Description

Standards supported

TC-PAM without OPTIS

ETSI SDSL, TM6(00)10

Power consumption

11.3W at 136 kbps

15.0W at 1.554 Mbps

16.5W at 2.312 Mbps

Maximum data rates (per port)

2.312 Mbps

Maximum data rate (per card)

18.5 Mbps downstream

5.0 Mbps for odd ports upstream

5.0 Mbps for even ports upstream

External interfaces

8 (no connectors on card)

Internal hardware

MPC850 3.3V power 40-MHz CPU

Dimensions

Height: 6.07 in. (15.42 cm)

Depth: 8.50 in. (21.59 cm)

Width: 0.88 in. (2.24 cm)

Weight

0.70 lb (0.32 kg)

Minimum software and network management requirement

Cisco IOS 12.1.(7) DA

CDM 3.3(3) (optional)

A.1.9 DS3/2DS3 NI-2 Card

Table A-9 lists the specifications for the DS3/2DS3 NI-2 card.


Table A-9: DS3/2DS3 NI-2 Card Specifications
Specification Description

Internal hardware

150 MHz RC64475 CPU
Galileo GT64120 system controller
1 M x 32 bootflash
4 M x 32 flash
512 KB boot EEPROM

Dimensions

Height: 12.38 in. (31.45 cm)
Depth: 8.50 in. (21.59 cm)
Width: 1.80 in. (4.57 cm)

Weight

3.0 lb (1.36 kg)

Layer 2 protocol

ATM

External interfaces

Three DS3/E3 (44.736 Mbps) coaxial ports

Connector type

BNC1

Impedance

75 ohms (nominal)

Line encoding

B3ZS

Framing

C-bit parity, optionally PLCP with M23, otherwise add/drop multiplexer (ADM)

Power consumption

33.5W

Minimum software and network management requirement

Cisco IOS—Release 12.1(5)DA2

CDM—Release 3.3(1) (optional)

1The Bayonet-Neill-Concelman (BNC) connectors are located on the E3 I/O module.
2The minimum Cisco IOS software requirement for a redundant NI-2 card configuration is 12.1(7)DA.

A.1.10 DS3+T1/E1 IMA NI-2 Card

Table A-10 lists the specifications for the DS3+T1/E1 IMA NI-2 card.


Table A-10: DS3+T1/E1 IMA NI-2 Card Specifications
Specification Description

Internal hardware

150 MHz RC64475 CPU
Galileo GT64120 system controller
1Mx32 bootflash (4 MB)
4Mx32 flash (16 MB)
512 KB boot EPROM

Dimensions

Height: 12.38 in. (31.45 cm)

Depth: 8.50 in. (21.59 cm)

Width: 1.80 in. (4.57 cm)

Weight

3.0 lb (1.36 kg)

External interfaces1

Eight T1(1.544 Mbps)/E1 (2.048 Mbps) RJ-48 ports

Connector types2

E1/T1—RJ-48

Impedance

E1—120 ohms (nominal)

Line encoding

E1—AMI or HDB3

Framing

E1—PCM30 or CRC4

Transmission distance

E1—Short haul: 0 to 655 feet (0 to 199.64 meters), long haul: > 655 feet (199.64 meters)
no span power

Power consumption

32.5W

Minimum software and network management requirement

Cisco IOS—Release 12.1(7)DA

CDM—Release 3.3(3) (optional)

1All external interfaces for the DS3+T1/E1 IMA NI-2 card are located on the I/O module.
2All trunk and subtend connectors for the DS3+T1/E1 IMA NI-2 card are located on the I/O module.

A.1.11 OC-3c/OC-3c NI-2 Card

Table A-11 lists the specifications of the single-mode and multimode versions of the OC-3c/OC-3c NI-2 card.


Table A-11: OC-3c/OC-3c NI-2 Card Specifications
Specification Description

Internal hardware

150 MHz RC64475 CPU
Galileo GT64120 system controller
1 M x 32 bootflash1 (4 MB)
4 M x 32 Flash
512 KB boot EPROM

Dimensions

Height: 12.38 in. (31.45 cm)
Depth: 8.50 in. (21.59 cm)
Width: 1.80 in. (4.57 cm)

Weight

3.0 lb (1.36 kg)

Layer 2 protocol

ATM

Power consumption

33.5W

Minimum software and network management requirement

Cisco IOS—Release 12.0(5)DA2

CDM—Release 3.0 (optional)

Single Mode Card Multimode Card

External interfaces

Two OC-3c/STM-1 (155 Mbps) single-mode ports

Two OC-3c/STM-1 (155 Mbps) multimode ports

Connector type

SC-PC

SC-PC

Fiber type

Intermediate reach single mode

Multimode

Average transmitted power

-15 to -8 dBm

-20 to -14 dBm

Average received power

-8 dBm

-11 dBm

Transmission distance

Up to 20 km (12 miles)

Up to 2 km (1.2 miles)

Wavelength

1310 nm

1300 nm

1The version of the OC-3c/OC-3c NI-2 card with enhanced upstream bandwidth features (NI2-155SM-155SM2 and NI2-155MM-155MM2) has a 2M x 32 bootflash (8 MB).
2The minimum Cisco IOS software requirement for a redundant NI-2 card configuration is 12.1(7)DA.

A.1.12 I/O Module

Table A-12 lists the specifications for the E3, E1, and OC-3c I/O modules.


Table A-12: I/O Module Specifications
Specification E3 E1 OC-3c

Dimensions

Height: 2.34 in. (5.94 cm)

Depth: 1.19 in. (3.022 cm)

Width: 17.0 in. (43.18 cm)

Height: 2.34 in. (5.94 cm)

Depth: 1.18 in. (3 cm)

Width: 17.0 in. (43.18 cm)

Height: 2.34 in. (5.94 cm)

Depth: 0.785 in. (1.99 cm)

Width: 17.0 in. (43.18 cm)

Weight

1.75 lb (0.79 kg)

1.65 lb (0.75 kg)

1.2 lb (0.54 kg)

External interfaces

Three E3 (32.064 Mbps) coaxial ports

Eight E1 (2.048 Mbps) receptacle connectors

Not applicable

Connector type

E3—BNC

E1—RJ-48

Not applicable

Power consumption

Not applicable

Not applicable

Not applicable

Minimum software and network management requirement

Cisco IOS—Release 12.1(4)DA

CDM—Release 3.3 (optional)

Cisco IOS—Release 12.1(7)DA2

CDM—Release 3.3(2) (optional)

Cisco IOS—Release 12.0(5)DA

CDM—Release 3.0 (optional)

A.1.13 PEM

Table A-13 lists the specifications for the PEM.


Table A-13: PEM Specifications
Specification PEM

Dimensions

Height: 2.45 in. (6.22 cm)

Depth: 10.86 in. (27.58 cm)

Width: 7.96 in. (20.22 cm)

Weight

5.85 lb (2.65 kg)

Power consumption

50.159W

Minimum software and network management requirement

Cisco IOS—Release 12.0(5)DA

CDM—Release 3.0 (optional)

A.1.14 Fan Tray

Table A-14 lists the specifications for the fan tray.


Table A-14: Fan Tray Specifications
Specification Description

Dimensions

Height: 1.5 in. (3.81 cm)

Depth: 8.75 in. (22.23 cm)

Width: 8.5 in. (21.59 cm)

Weight

2.6 lb (1.18 kg)

Power consumption

34.5W

Minimum software and network management requirement

Cisco IOS—Release 12.1(4)DA

CDM—Release 3.2 (optional)

A.2 Software Specifications

Table A-15 lists Cisco 6260 system software specifications.


Table A-15: Software Specifications
Specification Description

Management protocols

IOS software support for SNMP to Cisco EMF1

Management applications

  • Cisco IOS

  • CDM

Management interfaces

In band—ATM VC
Out of band—10BaseT Ethernet, console, auxiliary