This appendix provides the technical specifications for the Cisco 6260 system. The appendix contains the following sections:
This section details the specifications for the following hardware components:
Table A-1 lists the hardware specifications of the Cisco 6260 system.
Specification | Description | ||
---|---|---|---|
Dimensions |
| 13.43 RUs—23.5 in. x 17.5 in. x 11.0 in. (59.7 cm x 44.5 cm x 28.0 cm) | |
Weight |
| Empty—Approximately 37.5 lb (17.0 kg) | |
Network interface | ATM OC-3c (single- or multimode fiber), ATM E3, ATM E1 Note When the DS3/2DS3 NI-2 card is installed in the Cisco 6260 chassis, it assumes E3 functionality. | ||
ADSL interface | DMT—Up to 8.032 Mbps downstream/864 kbps upstream | ||
SDSL interface | 2B1Q—Up to 1168 kbps upstream and downstream | ||
SHDSL interface | TC-PAM1 | ||
Craft interface | Console terminal connection on the NI-2 card | ||
Management access |
| ||
External alarm contacts | Single dry contact alarm input (NO) | ||
Power requirements |
Note See "Preparing for Installation," for detailed power requirements. | ||
CO operating requirements | Temperature | 41º to 104ºF (5º to 40ºC)—Operating | |
Maximum heat dissipation for a fully loaded chassis | 4097 BTUs/hour | ||
Acoustic noise | 60 dB at normal fan speed | ||
Subtending |
|
1TC-PAM = trellis coded pulse amplitude modulation |
Table A-2 lists the specifications for the 4xDMT.
Specification | Description |
---|---|
Standards supported | ITU G.dmt |
External interfaces | 4 (no connectors on card) |
Data rates (per port) | Upstream: Up to 864 kbps |
Internal hardware
|
|
Dimensions | Height: 6.07 in. (15.42 cm) |
Weight | 0.875 lb (0.4 kg) |
Power consumption | 16.5W |
Minimum software and network management requirement | Cisco IOS—Release 12.0(5)DA CDM1—Release 3.0 (optional) |
1CDM = Cisco DSL Manager |
Table A-3 lists the specifications for the 4xDMT over ISDN.
Specification | Description |
---|---|
Data rates (per port) | Upstream: 32 to 864 kbps in increments of 32 kbps Downstream: 32 to 8032 kbps in increments of 32 kbps Symmetrical: Matches upstream and downstream rates |
Internal hardware |
|
Dimensions | Height: 6.07 in. (15.42 cm) Depth: 8.50 in. (21.59 cm) Width: 0.88 in. (2.24 cm) |
Weight | 0.875 lb (0.4 kg) |
Power consumption | 16.5W |
Minimum software and network management requirement | Cisco IOS—Release 12.1(3)DA CDM—Release 3.2 (optional) |
Table A-4 lists the specifications for the 4xflexi.
Specification | Description |
---|---|
Standards supported | ITU G.dmt (G.992.1) |
Power consumption | 17.5W |
Data rates (per port) | Downstream: 8.032 Mbps |
External interfaces | 4 (no connectors on card) |
Internal hardware | AMD 186-based 3.3V 18-MHz CPU 128 KB SRAM 512 K flash |
Dimensions | Height: 6.07 in. (15.42 cm) Depth: 8.50 in. (21.59 cm) Width: 0.88 in. (2.24 cm) |
Weight | 0.875 lb (0.4 kg) |
Minimum software and network management requirement | Cisco IOS—Release 12.1(4)DA CDM—Release 3.2 (optional) |
Table A-5 lists the specifications for the 4xSDSL.
Specification | Description |
Standards supported | ITU G.991.1 |
External interfaces | 4 (no connectors on card) |
Data rates (per port) | Downstream: 1168 kbps |
Line encoding | 2B1Q |
Internal hardware | AMD 186-based 3.3V 18-MHz CPU 128 KB SRAM 512 K flash |
Dimensions | Height: 6.07 in. (15.42 cm) |
Weight | 0.875 lb (0.4 kg) |
Power consumption | 9W |
Minimum software and network management requirement | Cisco IOS—Release 12.1(4)DA CDM—Release 3.0 (optional) |
Table A-6 lists the specifications for the 8xDMT.
Specification | Description |
---|---|
Standards supported |
|
External interfaces | 8 (no connectors on card) |
Data rates (per port) | Upstream: Up to 1024 kbps |
Internal hardware |
|
Dimensions | Height: 6.07 in. (15.42 cm) |
Weight | 0.875 lb (0.4 kg) |
Power consumption | 24W |
Minimum software and network management requirement | Cisco IOS—Release 12.1(6)DA CDM—Release 3.3(2) |
Table A-7 lists the specifications for the 8xDMT over ISDN.
Specification | Description |
---|---|
Standards supported |
|
External interfaces | 8 (no connectors on card) |
Data rates (per port) | Upstream: Up to 1024 kbps |
Framing modes | Overhead Framing Mode 3 supported |
Internal hardware |
|
Dimensions | Height: 6.07 in. (15.42 cm) |
Weight | 0.875 lb (0.4 kg) |
Power consumption | 24W |
Minimum software and network management requirement | Cisco IOS—Release 12.2(5) DA |
Table A-8 lists the specifications for the 8xG.SHDSL.
Specification | Description |
---|---|
Standards supported | TC-PAM without OPTIS ETSI SDSL, TM6(00)10 |
Power consumption | 11.3W at 136 kbps 15.0W at 1.554 Mbps 16.5W at 2.312 Mbps |
Maximum data rates (per port) | 2.312 Mbps |
Maximum data rate (per card) | 18.5 Mbps downstream 5.0 Mbps for odd ports upstream 5.0 Mbps for even ports upstream |
External interfaces | 8 (no connectors on card) |
Internal hardware | MPC850 3.3V power 40-MHz CPU |
Dimensions | Height: 6.07 in. (15.42 cm) Depth: 8.50 in. (21.59 cm) Width: 0.88 in. (2.24 cm) |
Weight | 0.70 lb (0.32 kg) |
Minimum software and network management requirement | Cisco IOS 12.1.(7) DA CDM 3.3(3) (optional) |
Table A-9 lists the specifications for the DS3/2DS3 NI-2 card.
Specification | Description |
---|---|
Internal hardware | 150 MHz RC64475 CPU |
Dimensions | Height: 12.38 in. (31.45 cm) |
Weight | 3.0 lb (1.36 kg) |
Layer 2 protocol | ATM |
External interfaces | Three DS3/E3 (44.736 Mbps) coaxial ports |
Connector type | BNC1 |
Impedance | 75 ohms (nominal) |
Line encoding | B3ZS |
Framing | C-bit parity, optionally PLCP with M23, otherwise add/drop multiplexer (ADM) |
Power consumption | 33.5W |
Minimum software and network management requirement | Cisco IOS—Release 12.1(5)DA2 CDM—Release 3.3(1) (optional) |
1The Bayonet-Neill-Concelman (BNC) connectors are located on the E3 I/O module. 2The minimum Cisco IOS software requirement for a redundant NI-2 card configuration is 12.1(7)DA. |
Table A-10 lists the specifications for the DS3+T1/E1 IMA NI-2 card.
Specification | Description |
---|---|
Internal hardware | 150 MHz RC64475 CPU |
Dimensions | Height: 12.38 in. (31.45 cm) Depth: 8.50 in. (21.59 cm) Width: 1.80 in. (4.57 cm) |
Weight | 3.0 lb (1.36 kg) |
External interfaces1 | Eight T1(1.544 Mbps)/E1 (2.048 Mbps) RJ-48 ports |
Connector types2 | E1/T1—RJ-48 |
Impedance | E1—120 ohms (nominal) |
Line encoding | E1—AMI or HDB3 |
Framing | E1—PCM30 or CRC4 |
Transmission distance | E1—Short haul: 0 to 655 feet (0 to 199.64 meters), long haul: > 655 feet (199.64 meters) |
Power consumption | 32.5W |
Minimum software and network management requirement | Cisco IOS—Release 12.1(7)DA CDM—Release 3.3(3) (optional) |
1All external interfaces for the DS3+T1/E1 IMA NI-2 card are located on the I/O module. 2All trunk and subtend connectors for the DS3+T1/E1 IMA NI-2 card are located on the I/O module. |
Table A-11 lists the specifications of the single-mode and multimode versions of the OC-3c/OC-3c NI-2 card.
Specification | Description | |
Internal hardware | 150 MHz RC64475 CPU | |
Dimensions | Height: 12.38 in. (31.45 cm) | |
Weight | 3.0 lb (1.36 kg) | |
Layer 2 protocol | ATM | |
Power consumption | 33.5W | |
Minimum software and network management requirement | Cisco IOS—Release 12.0(5)DA2 CDM—Release 3.0 (optional) | |
Single Mode Card | Multimode Card | |
External interfaces | Two OC-3c/STM-1 (155 Mbps) single-mode ports | Two OC-3c/STM-1 (155 Mbps) multimode ports |
Connector type | SC-PC | SC-PC |
Fiber type | Intermediate reach single mode | Multimode |
Average transmitted power | -15 to -8 dBm | -20 to -14 dBm |
Average received power | -8 dBm | -11 dBm |
Transmission distance | Up to 20 km (12 miles) | Up to 2 km (1.2 miles) |
Wavelength | 1310 nm | 1300 nm |
Table A-12 lists the specifications for the E3, E1, and OC-3c I/O modules.
Specification | E3 | E1 | OC-3c |
Dimensions | Height: 2.34 in. (5.94 cm) Depth: 1.19 in. (3.022 cm) Width: 17.0 in. (43.18 cm) | Height: 2.34 in. (5.94 cm) Depth: 1.18 in. (3 cm) Width: 17.0 in. (43.18 cm) | Height: 2.34 in. (5.94 cm) Depth: 0.785 in. (1.99 cm) Width: 17.0 in. (43.18 cm) |
Weight | 1.75 lb (0.79 kg) | 1.65 lb (0.75 kg) | 1.2 lb (0.54 kg) |
External interfaces | Three E3 (32.064 Mbps) coaxial ports | Eight E1 (2.048 Mbps) receptacle connectors | Not applicable |
Connector type | E3—BNC | E1—RJ-48 | Not applicable |
Power consumption | Not applicable | Not applicable | Not applicable |
Minimum software and network management requirement | Cisco IOS—Release 12.1(4)DA CDM—Release 3.3 (optional) | Cisco IOS—Release 12.1(7)DA2 CDM—Release 3.3(2) (optional) | Cisco IOS—Release 12.0(5)DA CDM—Release 3.0 (optional) |
Table A-13 lists the specifications for the PEM.
Specification | PEM |
Dimensions | Height: 2.45 in. (6.22 cm) Depth: 10.86 in. (27.58 cm) Width: 7.96 in. (20.22 cm) |
Weight | 5.85 lb (2.65 kg) |
Power consumption | 50.159W |
Minimum software and network management requirement | Cisco IOS—Release 12.0(5)DA CDM—Release 3.0 (optional) |
Table A-14 lists the specifications for the fan tray.
Specification | Description |
Dimensions | Height: 1.5 in. (3.81 cm) Depth: 8.75 in. (22.23 cm) Width: 8.5 in. (21.59 cm) |
Weight | 2.6 lb (1.18 kg) |
Power consumption | 34.5W |
Minimum software and network management requirement | Cisco IOS—Release 12.1(4)DA CDM—Release 3.2 (optional) |
Table A-15 lists Cisco 6260 system software specifications.
Specification | Description |
---|---|
Management protocols | IOS software support for SNMP to Cisco EMF1 |
Management applications |
|
Management interfaces | In band—ATM VC |
1EMF = Element Management Framework |