cc/td/doc/product/dsl_prod/6015
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table of Contents

Technical Specifications
A.1 Hardware Specifications
A.2 Software Specifications

Technical Specifications


This appendix provides the technical specifications for the Cisco 6015 system. The appendix contains the following sections:

A.1 Hardware Specifications

This section details the specifications for the following hardware components:

A.1.1 Cisco 6015 System Specifications

Table A-1 lists the hardware specifications of the Cisco 6015 system.

Table A-1   Hardware Specifications

Specification Description

Dimensions

Cisco 6015
AC/DC converter tray1
AC/DC converter

3 RUs2—5.25 in. x 17.48 in. x 11.02 in. (13.34 cm x 44.40 cm x 27.99 cm)
1 RU—1.75 in. x 19 in. x 13 in. (4.45 cm x 48.26 cm x 33.02cm)
1 RU—1.75 in. x 5.75 in. x 13 in. (4.45 cm x 14.61 cm x 33.02 cm)

Weight

Cisco 6015

AC/DC converter

Empty—Approximately 14.5 lb (6.59 kg)
Loaded—Approximately 26.04 lb (11.84 kg)
6 lb (2.73 kg)

Network interface

DS3+T1/E1IMA

  • DS3 WAN uplink
  • T1/E1 interface configured as either WAN or subtend
  • T1/E1 interfaces can be configured in up to four IMA groups

ATM OC-3c (single- or multimode fiber)

ADSL interface

CAP—Up to 7.168 Mbps downstream/1.088 Mbps upstream per port
DMT—Up to 8.032 Mbps downstream/1024 kbps upstream per port
G.lite—Up to 1.536 Mbps downstream/512 kbps upstream per port

SHDSL interface

TC-PAM3—Up to 2.312 Mbps downstream/upstream

Craft interface

Console terminal connection on the NI-2 card

Management access

  • RJ-45 interface for craft alarm discovery
  • RJ-45 Ethernet
  • ATM in-band management

External alarm contacts

Single dry contact alarm input, Normally Open (NO)

Power requirements

  • -48/-60V DC
  • 120/240 AC, with optional AC/DC converter

Note See "Preparing for Installation," for detailed power requirements.

 

Commercial operating requirements

Temperature


Altitude

Humidity

41 to 104ºF (5 to 40ºC)—Operating
23 to 131ºF (-5 to 55ºC)—Short-term operating

-197 to 13,123 feet (-60 to 4000 meters)

5 to 90% (noncondensing)

Outside Plant operating requirements

Temperature

Altitude

Humidity

-40 to 149ºF (-40 to 65ºC)—Operating

-197 to 13,123 feet (-60 to 4000 meters)

5 to 95% (noncondensing)

Subtending

  • I/O module
  • One OC-3c connection on the OC-3c/OC-3c NI-2 card
1For additional hardware specifications for the AC/DC converter or converter tray, refer to the AC/DC converter documentation.

2RU = rack unit. An RU is equal to 1.75 inches (4.45 cm).

3TC-PAM = trellis coded pulse amplitude modulation.

A.1.2 4xflexi Specifications

Table A-2 lists the specifications for the 4xflexi.

Table A-2   4xflexi Specifications

Specification DMT Mode CAP Mode G.lite Mode

Standards supported

ITU G.dmt (G.992.1)
ANSI T1.413

RADSL1

ITU G.lite (G.992.2)

Power consumption

17.5W

13.5W

13W

Maximum data rates (per port)

Downstream

Upstream


8.032 Mbps

864 kbps


7.168 Mbps

1.088 Mbps


1.536 Mbps

512 kbps

External interfaces

4 (no connectors on card)

Internal hardware

AMD 186-based 3.3V 18-MHz CPU

128-KB SRAM

512K flash

Dimensions

Height: 6.07 in. (15.42 cm)

Depth: 8.50 in. (21.59 cm)

Width: 0.88 in. (2.24 cm)

Weight

0.875 lb (0.4 kg)

Minimum software and network management requirement

Cisco IOS—Release 12.1(4)DA

CDM2—Release 3.2 (optional)

1RADSL = rate-adaptive digital subscriber line.

2CDM = Cisco DSL Manager

A.1.3 8xDMT Specifications

Table A-3 lists the specifications for the 8xDMT.

Table A-3   8xDMT Specifications

Specification Description

Standards supported

  • ANSI T1.413-Issue 2, Category 1 only
  • ANSI T1.413-Issue 2, Annex F (Reduced NEXT)\
  • Universal Test & Operations PHY for ATM, Level 2; A standard for transport of ATM cells over a 16-bit parallel data bus. Refer to the ATM Forum document af-phy-0039.000.
  • ITU G.992.1, Annex A (G.dmt)
  • ITU G.992.2. (G.lite)
  • ITU G.994.1. (G.hs)

External interfaces

8 (no connectors on card)

Data rates (per port)

Upstream: Up to 1024 kbps
Downstream: Up to 8.064 Mbps

Internal hardware

  • 40 MHz Motorola MPC850 microprocessor
  • 8MB SDRAM
  • 1 Mb boot flash
  • 1 kb serial EEPROM

Dimensions

Height: 6.07 in. (15.42 cm)
Depth: 8.50 in. (21.59 cm)
Width: 0.88 in. (2.24 cm)

Weight

0.875 lb (0.4 kg)

Power consumption

24W

Minimum software and network management requirement

Commercial version:

  • Cisco IOS—Release 12.1(6)DA
  • CDM1—Release 3.3(2) (optional)

Outside-plant version:

  • Cisco IOS—Release 12.2(5)DA
  • CDM—Release 3.4 (optional)
1CDM = Cisco DSL Manager

A.1.4 8xDMT Over ISDN Specifications

Table A-4 lists the specifications for the 8xDMT over ISDN.

Table A-4   8xDMT Over ISDN Specifications

Specification Description

Standards supported

  • Universal Test & Operations PHY for ATM, Level 2; standard for transport of ATM cells over a 16-bit parallel data bus. Refer to ATM Forum document af-phy-0039.000.
  • ITU G.992.1 (G.dmt), Annex B/ETSI
  • ITU G.994.1 (G.hs)
  • ETSI TS 101 388 V.1.1.1/(draft) TM6(98)12
  • TS102 080 v1.3.2 -Support for 2B1Q and 4B3T ISDN

External interfaces

8 (no connectors on card)

Data rates (per port)

Upstream: Up to 1024 kbps
Downstream: Up to 7.616 Mbps

Framing mode

Overhead Framing Mode 3 supported

Internal hardware

  • 40 MHz Motorola MPC850 microprocessor
  • 64 MB SDRAM
  • 16 Mb boot Flash
  • 1 KB serial EEPROM

Dimensions

Height: 6.07 in. (15.42 cm)
Depth: 8.62 in. (21.89 cm)
Width: 0.88 in. (2.24 cm)

Weight

0.875 lb (0.4 kg)

Power consumption

24 W

Minimum software and network management requirement

Cisco IOS—Release 12.2(5) DA

CDM—Release 3.3(3-2) (optional)

A.1.5 8xG.SHDSL Specifications

Table A-5 lists the specifications for the 8xG.SHDSL.

Table A-5   8xG.SHDSL Line Card Specifications

Specification Description

Standards supported

TC-PAM without OPTIS

ITU G.991.2

ITU G.994.1

ETSI SDSL, TM6(00)10

ETSI SDSL DRAFT (TS 101 524)

Power consumption

11.3W at 136 kbps

15.0W at 1.554 Mbps

16.5W at 2.312 Mbps

Maximum data rates (per port)

2.312 Mbps

Maximum data rate (per card)
Minimum software Cisco IOS 12.1(7)DA2

18.5 Mbps downstream
5.0 Mbps for odd ports upstream
5.0 Mbps for even ports upstream

Maximum data rate (per card)
Minimum software Cisco IOS 12.2(7)

18.5 Mbps downstream
18.5 Mbps upstream

External interfaces

8 (no connectors on card)

Internal hardware

MPC850 3.3V power 40-Mhz CPU

Dimensions

Height: 6.07 in. (15.42 cm)

Depth: 8.50 in. (21.59 cm)

Width: 0.88 in. (2.24 cm)

Weight

0.70 lb (0.32 kg)

Minimum software and network management requirement

Cisco IOS 12.1(7)DA2

CDM 3.3.3 (optional)

Minimum requirements for rate adaptive DSL.

Cisco IOS 12.2(7)

CDM 3.4 (optional)

A.1.6 DS3+T1/E1 IMA and ITEMP DS3+T1/E1 IMA NI-2 Cards Specifications

Table A-6 lists the specifications for the DS3+T1/E1 IMA and the ITEMP DS3+T1/E1 IMA NI-2 cards.

Table A-6   DS3+T1/E1 IMA and ITEMP DS3+T1/E1 IMA NI-2 Card Specifications

Specification Description

Internal hardware

150 MHz RC64475 CPU

Galileo GT64120 system controller

1M x 32 bootflash

4M x 32 Flash

512 KB boot EPROM

Dimensions

Height: 12.38 in. (31.45 cm)

Depth: 8.50 in. (21.59 cm)

Width: 1.80 in. (4.57 cm)

Weight

3.0 lb (1.36 kg)

External interfaces

One DS3 (44.736 Mbps) coaxial port

Eight T1(1.544 Mbps)/E1 (2.048 Mbps) RJ-48 ports

Connector type

DS3—BNC1

E1/T1—RJ-482

Impedance

DS3—75 ohms (nominal)

T1—100 ohms (nominal)

E1—120 ohms (nominal)

Line encoding

DS3—B3ZS

T1—AMI or B8ZS

E1—AMI or HDB3

Framing

DS3—C-bit parity, optionally PLCP with M23, otherwise ADM3

T1—SF or ESF

E1—PCM30 or CRC4

Transmission distance

DS3—Short haul: <225 feet (68.58 meters), long haul: 225 to 450 feet (68.58 to 137.16 meters)

T1/E1—Short haul: 0 to 655 feet (0 to 199.64 meters), long haul: >655 feet (199.64 meters)
no span power

Power consumption

32.5W

Minimum software and network management requirement

Commercial environment:

  • Cisco IOS—Release 12.1(4)DA
  • CDM—Release 3.2 (optional)

Outside-plant environment:

  • Cisco IOS—Release 12.2(5)DA
  • CDM—Release 3.4 (optional)
1The BNC connectors are located on the I/O module.

2The E1 and T1 connectors are located on the I/O module.

3ADM = add drop multiplexor

A.1.7 OC-3c/OC-3c NI-2 Card Specifications

Table A-7 lists the specifications of the single-mode and multimode versions of the OC-3c/OC-3c NI-2 card.

Table A-7   OC-3c/OC-3c NI-2 Card Specifications

Specification Description

Internal hardware

150 MHz RC64475 CPU
Galileo GT64120 system controller
1 M x 32 bootflash1 (4 MB)
4 M x 32 Flash (16 MB)
512 KB boot EPROM

Dimensions

Height: 12.38 in. (31.45 cm)
Depth: 8.50 in. (21.59 cm)
Width: 1.80 in. (4.57 cm)

Weight

3.0 lb (1.36 kg)

Layer 2 protocol

ATM

Power consumption

33.5W

Minimum software and network management requirement

Cisco IOS—Release 12.2(5)DA

CDM—Release 3.2 (optional)

Single Mode Card Multimode Card

External interfaces

Two OC-3c/STM-1 (155 Mbps) single-mode ports

Two OC-3c/STM-1 (155 Mbps) multimode ports

Connector type

SC-PC

SC-PC

Fiber type

Intermediate reach single mode

Multimode

Average transmitted power

-15 to -8 dBm

-20 to -14 dBm

Average received power

-8 dBm

-11 dBm

Transmission distance

Up to 20 km (12 miles)

Up to 2 km (1.2 miles)

Wavelength

1310 nm

1300 nm

1The version of the OC-3c/OC-3c NI-2 card with enhanced upstream bandwidth features (NI2-155SM-155SM2 and NI2-155MM-155MM2) has a 2M x 32 bootflash (8 MB).

A.1.8 I/O Module Specifications

Table A-8 lists the specifications for the I/O module.

Table A-8   I/O Module Specifications

Specification Description

Dimensions

Height: 1.688 in. (4.29 cm)

Depth: 9.375 in. (23.813 cm)

Width: 3.375 in. (8.573 cm)

Weight

0.64 lb (0.29 kg)

External interfaces

One DS3 (44.736 Mbps) coaxial port

Eight T1 (1.544 Mbps)/E1 (2.048 Mbps) RJ-48 ports

Connector type

DS3—BNC1

E1/T1—RJ-48

Power consumption

3W

Minimum software and network management requirement

Use with a DS3+T1/E1 IMA NI-2 card in a commercial environment

Cisco IOS—Release 12.1(4)DA

CDM2—Release 3.2

Use with an ITEMP DS3+T1/E1 IMA NI-2 card in an outside-plant environment

Cisco IOS—Release 12.1(6)DA

CDM—Release 3.4

Use with an OC-3c/OC-3c NI-2 card in a commercial environment

Cisco IOS—Release 12.2(5)DA

CDM—Release 3.2

1BNC = Bayonet-Neill Concelman.

2CDM = Cisco DSL Manager

A.1.9 DSL Interface Module Specifications

Table A-9 lists the specifications for the DSL interface module.

Table A-9   DSL Interface Module Specifications

Specification Description

Dimensions

Height: 1.375 in. (3.493 cm)

Depth: 9.375 in. (23.813 cm)

Width: 3.375 in. (8.573 cm)

Weight

0.71 lb (0.32 kg)

Data connectors

Two 50-pin Champ connectors

Power consumption

Not applicable.

Minimum software and network management requirement

Cisco IOS—Release 12.1(4)DA

CDM—Release 3.2 (optional)

A.1.10 DC PEM Specifications

Table A-10 lists the specifications for the DC PEM.

Table A-10   DC PEM Specifications

Specification Description

Dimensions

Height: 1.56 in. (3.96 cm)

Depth: 9.875 in. (25.08 cm)

Width: 3.375 in. (8.573 cm)

Weight

1.08 lb (0.49 kg)

Power consumption

20W

Minimum software and network management requirement

Cisco IOS—Release 12.1(4)DA

CDM—Release 3.2 (optional)

A.1.11 Fan Module Specifications

Table A-11 lists the specifications for the fan module.

Table A-11   Fan Module Specifications

Specification Description

Dimensions

Height: 5.0 in. (12.7 cm)

Depth: 9.375 in. (23.813 cm)

Width: 1.125 in. (2.86 cm)

Weight

0.87 lb (0.40 kg)

Power consumption

9W

Minimum software and network management requirement

Cisco IOS—Release 12.1(4)DA

CDM—Release 3.2 (optional)

A.2 Software Specifications

Table A-12 lists Cisco 6015 system software specifications.

Table A-12   Software Specifications

Specification Description

Management protocols

IOS software support for SNMP to Cisco EMF1

Management applications

  • Cisco IOS
  • CDM

Management interfaces

In band—ATM VC
Out of band—10BaseT Ethernet, console, auxiliary

1EMF = Element Management Framework


hometocprevnextglossaryfeedbacksearchhelp
Posted: Wed Jan 8 12:27:48 PST 2003
All contents are Copyright © 1992--2002 Cisco Systems, Inc. All rights reserved.