cc/td/doc/product/cddi
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table of Contents

Workgroup EISA SGI Adapter Technical Specifications

Workgroup EISA SGI Adapter Technical Specifications

Table A-1gives a detailed description of the workgroup CDDI/FDDI EISA SGI adapter specifcations.


Workgroup CDDI/FDDI EISA SGI Adapter Specifications
Single Attachment FDDI EISA SGI Adapter Single Attachment CDDI EISA SGI Adapter
Physical dimensions:
Height
Depth
Width
Weight
4.5" (11.4 cm)
10.3" (26.2 cm)
0.75" (1.9 cm)
9 oz. (255 g)
4.5" (11.4 cm)
10.3" (26.2 cm)
0.75" (1.9 cm)
9.5 oz. (270 g)
Power requirements +5V @ 2A (maximum)
+12V @ 150 mA (maximum)
+5V @ 1.8A (maximum)
+12V @ 150 mA (maximum)
Thermal dissipation 9.3 watts (maximum) 8.3 watts (maximum)
Environmental conditions:
Operating temperature
Storage temperature

Relative humidity
32 to 104ºF (0 to 40ºC)
-40 to 167ºF (-40 to 75ºC)
10 to 90% (non-condensing)
32 to 104ºF (0 to 40ºC)
-40 to 167ºF (-40 to 75ºC)
10 to 90% (non-condensing)
EMI certifications FCC Class A (47 CFR, Part 15), CE Mark, and VCCI Class 2 FCC Class A (47 CFR, Part 15), CE Mark, and VCCI Class 2
Network connector MIC RJ-45
Station-to-station cabling Up to 2 kilometers of either 62.5/125-micron or 50/125-micron multimode fiber Category 5 UTP: up to 100 meters
IBM Type 1 STP: up to 100 meters
Faceplate indicators Status, ringop Status, ringop
EISA compliance EISA specification 3.12 EISA specification 3.12

Dual Attachment FDDI EISA SGI Adapter Dual Attachment CDDI EISA SGI Adapter
Physical dimensions:
Height
Depth
Width
Weight
4.4" (11.4 cm)
13.25" (33.6 cm)
0.75" (1.9 cm)
9 oz. (255 g)
4.4" (11.4 cm)
13.25" (33.6 cm)
0.75" (1.9 cm)
9.5 oz. (270 g)
Power requirements +5V @ 2A (maximum) +5V @ 550 mA (maximum)
+12V @ 60 mA (maximum)
Thermal dissipation 9.3 watts (maximum) 8.3 watts (maximum)
Environmental conditions:
Operating temperature
Storage temperature

Relative humidity
32 to 104ºF (0 to 40ºC)
-40 to 167ºF (-40 to 75ºC)
10 to 90% (non-condensing)
32 to 104ºF (0 to 40ºC)
-40 to 167ºF (-40 to 75ºC)
10 to 90% (non-condensing)
EMI certifications FCC Class A (47 CFR, Part 15), CE Mark, and VCCI Class 2 FCC Class A (47 CFR, Part 15), CE Mark, and VCCI Class 2
Network connector MIC RJ-45
Faceplate indicators Status, ringop Status, ringop
EISA compliance EISA Specification 3.12 EISA Specification 3.12

hometocprevnextglossaryfeedbacksearchhelp
Copyright 1989-1997 © Cisco Systems Inc.