cc/td/doc/product/cable/svc_ctrl/scmgtsu
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table Of Contents

List of Error Codes

List of Error Codes


List of Error Codes


This module provides a list of error codes that are used in the Java API.

List of Error Codes 

List of Error Codes

Error codes are used for interpreting the actual error for which an RpcErrorException was returned. Use the getErrorCode method to extract the error code.

The error code enumeration is given in the com.pcube.management.api.SMApiConstants interface. The following table gives a list of the error codes and their descriptions.

Table A-1 List of Error Codes

Error Code

Description

ERROR_CODE_BAD_SUBSCRIBER_MAPPING

A mapping was formatted badly or assigned to the subscriber illegally.

ERROR_CODE_DOMAIN_NOT_FOUND

The domain provided to the operation does not exist in the SM domain repository.

ERROR_CODE_ILLEGAL_ARGUMENT

One of the arguments provided to the method is illegal.

ERROR_CODE_ILLEGAL_SUBSCRIBER_NAME

The subscriber name provided has more than 40 characters or has illegal characters.

ERROR_CODE_NOT_A_SUSBCRIBER_DOMAIN

The domain provided to the operation exists in the SM domain repository but is not a subscriber domain.

ERROR_CODE_NUMBER_FORMAT

A VLAN mapping string provided to the API does not represent a decimal number.

ERROR_CODE_SUBSCRIBER_DOES_NOT_EXIST

The subscriber on which the operation is performed does not exist in the SM database.

ERROR_CODE_SUBSCRIBER_DOMAIN_ASSOCIATION

The subscriber exists in the SM database but is associated with a domain other than the one specified by the operation.

ERROR_CODE_SUBSCRIBER_MAPPING_CONGESTION

The mappings provided for the subscriber by the operation already belong to another subscriber.

ERROR_CODE_SUSBSCRIBER_ALREADY_EXISTS

The subscriber on which the operation was performed already exists in the SM database.

ERROR_CODE_DATABASE_EXCEPTION

Internal SM error - database error occurred during the operation.

ERROR_CODE_ARRAY_ACCESS

Internal SM error.

ERROR_CODE_ATTRIBUTE_NOT_FOUND

Internal SM error.

ERROR_CODE_CLASS_CAST

Internal SM error.

ERROR_CODE_CLASS_NOT_FOUND

Internal SM error.

ERROR_CODE_CLIENT_INTERNAL_ERROR

Internal error.

ERROR_CODE_CLIENT_OUT_OF_THREADS

Internal error.

ERROR_CODE_ILLEGAL_STATE

Internal SM error.

ERROR_CODE_OBJECT_NOT_FOUND

Internal SM error.

ERROR_CODE_OPERATION_NOT_FOUND

Internal SM error.

ERROR_CODE_OUT_OF_MEMORY

Internal SM error.

ERROR_CODE_RUNTIME

Internal SM error.

ERROR_CODE_NULL_POINTER

Internal SM error.

ERROR_CODE_SE_ERROR

Internal SM error. The SM could not perform the operation on the SCE device.

ERROR_CODE_UNKNOWN

Internal SM or API error.



hometocprevnextglossaryfeedbacksearchhelp

Posted: Thu May 31 04:20:01 PDT 2007
All contents are Copyright © 1992--2007 Cisco Systems, Inc. All rights reserved.
Important Notices and Privacy Statement.