Installing Cisco Cable Manager

Installing Cisco Cable Manager

This chapter describes the installation procedures for Cisco Cable Manager. Cisco IP Manager is optional and can be installed along with Cisco Cable Manager to provide configuration management features.

Cisco Cable Manager installation follows an installation script that checks the available disk space and prompts you to insert the required CD-ROMs.

There are three types of Cisco Cable Manager installations:

This chapter contains the following sections:

Installing Cisco Cable Manager without Cisco IP Manager Configuration Management

This installation procedure installs the following software on the server:

Complete the following tasks to install Cisco Cable Manager without Cisco IP Manager configuration management.


Note Cisco IP Manager is required for template-based configuration of Cisco uBR7200 series universal broadband routers. The default option can be selected for most installation prompts by pressing Enter.

Step 1 Log in as root user.

Step 2 Insert the Cisco Cable Manager CD-ROM into the CD-ROM drive.

Step 3 Copy the Cisco Cable Manager installation script to a directory on the server:

cp /cdrom/cdrom0/installCableMgr [server_directory]

Step 4 Go to the specified directory and enter:

./installCableMgr

The Cisco Cable Manager installation script runs and checks the available disk space. The minimum free disk space required is:

If not enough disk space is available, cancel the installation and ensure adequate disk space is available before running the installation script.

The Cisco Cable Manager installation script also checks if the CEMF and CEMF/EM are already installed. If not already installed, the Cisco Cable Manager installation script will prompt you to select and install these components.

Step 5 When prompted, insert the Cisco Element Manager Framework (CEMF) CD-ROM into the CD-ROM drive.

The Cisco Cable Manager installation script prompts you to specify if the following components are to be installed:

Step 6 At the Package Installation page, enter SR for the CEMF server (AVM) and CEMF client packages.

The Cisco Cable Manager installation script prompts you for:

The Cisco EMF server and client software are installed.

Step 7 When prompted, insert the Cisco Event Manager (CEMF/EM) CD-ROM into the CD-ROM drive.

Step 8 At the Package Installation page, enter S for the CEMF/EM server (EVm) and EM client packages.

When prompted for the AccessVision Flex LM, select N for the license file prompt. The license file will be installed automatically with the installation script. Selecting Yes starts the Flex LM daemon.

The CEMF/EM server and client software are installed.

Step 9 At the Package Installation page, enter S for the CEMF 2.1.4 Server Package (AVmp4) and C for the CEMF 2.1.4 Client Package (AVcp4.)

The CEMF server and client patch software are installed.

Step 10 When prompted, insert the Cisco Cable Manager CD-ROM into the CD-ROM drive.

Step 11 At the Add Package page, enter S for the Cisco Cable Manager server and client packages (CableMgrm).

The Cisco Cable Manager server and client patch software are installed.

Step 12 For CiscoView installation, when prompted enter 1 to select the CiscoView (CSCOcv) process. Also, enter the appropriate Cisco uBR7200 series universal broadband router model number of the desired CiscoView packages.

The complete installation installs the following software on the server:

Cisco Cable Manager also includes CiscoView for Cisco uBR7200 series universal broadband routers and cable modems.

The following installation log files are stored in the /tmp directory and show a record of the installed components:

These installation log files can be removed whenever the system is rebooted. To avoid losing these files, copy them to another directory for permanent storage.


Note The collect_sys_info script can be run on the Cisco Cable Manager server to display server resource statistics such as disk usage, memory, swap space, and other data. This script file is stored in the /opt/CSCOcem directory. The output of this script file is stored in the /tmp/collect_sys_info.log directory.

See the "Starting Cisco Cable Manager" section for post-installation and launch instructions.

Installing Cisco Cable Manager with Cisco IP Manager Configuration Management

To install Cisco Cable Manager with Cisco IP Manager configuration management, complete the following procedures:

Installing Oracle Server

Follow the Oracle server installation instructions from the Cisco IP Manager documentation to install the Oracle 8.04 database on the Oracle server with Solaris 2.6.

Cisco recommends that a qualified Oracle database administrator be available to verify proper installation and database setup.

For more details about customizing the Oracle database and installing Oracle, see the Oracle and Cisco IP Manager documentation.

Installing Cisco IP Manager

For Cisco Cable Manager, install the Cisco IP Manager (CIPM) server and GUI components.


Note Be sure the Oracle database is up and running before you begin the installation.

After successful installation of Oracle and starting the Oracle server, complete these steps to run Cisco IP Manager:

Step 1 Log in as user IPMGR.

Step 2 In the $INSTALL_IPMGR/SRVRS directory, locate the ipmgr.chs file and enter:

source ipmgr.csh

This command sets all the environment variables required to launch Cisco IP Manager.

Step 3 Copy the Cisco uBR7200 series universal broadband router configuration template files located on the Cisco Cable Manager 1.0 CD-ROM to the Cisco IP Manager directory:

cp /cdrom/cdrom0/ipmgrTemplates/*.cfg $IPMGR_GUI_HOME/GUI/java/login/

The following templates will be copied:

Step 4 Change the permission of all templates to ReadOnly. For example:

cd $IPMGR_GUI_HOME/GUI/java/login/ chmod 644 *.cfg

Refer to the Cisco IP Manager 2.0 Installation Guide instructions for detailed installation procedures.

Cisco Cable Manager Installation

Complete the following tasks to install Cisco Cable Manager:


Note Before installing Cisco Cable Manager, ensure the Oracle server, and Cisco IP Manager server and GUI software are installed.

Step 1 Log in as root user.

Step 2 Insert the Cisco Cable Manager CD-ROM into the CD-ROM drive.

Step 3 Copy the Cisco Cable Manager installation script to a directory on the server:

cp /cdrom/cdrom0/installCableMgr [server_directory]

Step 4 Go to the specified directory and enter:

./installCableMgr

The Cisco Cable Manager installation script runs and checks the available disk space. The minimum free disk space required is:

If not enough disk space is available, cancel the installation and ensure adequate disk space is available before running the installation script.

The Cisco Cable Manager installation script also checks if the CEMF and CEMF/EM are already installed. If not already installed, the Cisco Cable Manager installation script will prompt you to select and install these components.

Step 5 When prompted, insert the Cisco Element Manager Framework (CEMF) CD-ROM into the CD-ROM drive.

The Cisco Cable Manager installation script prompts you to specify if the following components are to be installed:

Step 6 At the Package Installation page, enter SR for the CEMF server (AVM) and CEMF client packages. The Cisco Cable Manager installation script prompts you for:

The Cisco EMF server and client software are installed.

Step 7 When prompted, insert the Cisco Event Manager (CEMF/EM) CD-ROM into the CD-ROM drive.

Step 8 At the Package Installation page, enter S for the CEMF/EM server (EVm) and EM client packages.

When prompted for the AccessVision Flex LM, select N for the license file prompt. The license file will be installed automatically with the installation script. Selecting Yes starts the Flex LM daemon.

The CEMF/EM server and client software are installed.

Step 9 At the Package Installation page, enter S for the CEMF 2.1.4 Server Package (AVmp4) and C for the CEMF 2.1.4 Client Package (AVcp4.)

The CEMF server and client patch software are installed.

Step 10 When prompted, insert the Cisco Cable Manager CD-ROM into the CD-ROM drive.

Step 11 At the Add Package page, enter S for the Cisco Cable Manager server and client packages (CableMgrm). The Cisco Cable Manager server and client patch software are installed.

Step 12 For CiscoView installation, when prompted enter 1 to select the CiscoView (CSCOcv) process. Also, enter the appropriate Cisco uBR7200 series universal broadband router model number of the desired CiscoView packages.

The complete installation installs the following software on the server:

Cisco Cable Manager also includes CiscoView for Cisco uBR7200 series universal broadband routers and cable modems.

The following installation log files are stored in the /tmp directory and show a record of the installed components:

These installation log files can be removed whenever the system is rebooted. To avoid losing these files, copy them to another directory for permanent storage.


Note The collect_sys_info script can be run on the Cisco Cable Manager server to display server resource statistics such as disk usage, memory, swap space, and other data. This script file is stored in the /opt/CSCOcem directory. The output of this script file is stored in the /tmp/collect_sys_info.log directory.

See the "Starting Cisco Cable Manager" section for post installation and launch instructions.

Environment Variables

After the installation is complete:

Step 1 Execute $AV_ROOT/config/setEV to set the environment variables. This is an interactive script. It sets the following ENV variables:

      setenv ORACLE_HOME /opt/oracle/product/8.0.5 setenv ORACLE_SID SPVM setenv ORACLE_USER grao setenv ORACLE_PW grao setenv ORACLE_DEBUG 1 setenv IPMGR_HOME /opt/ipmgr setenv LD_LIBRARY_PATH /lib:/usr/lib:/usr/local/lib:/usr/openwin/lib:/usr/openwin/lib/server:/opt/AV/lib:$ORACLE_HOME/lib:/$I PMGR_HOME/GUI/OrbixMT/2.3c03-01/lib:/opt/CSCOcem/lib setenv IT_CONFIG_PATH /opt/ipmgr/GUI/pack/OrbixMT/2.3c03-01/cfg setenv HOST \Qhostname\Q

Step 2 Edit the /opt/CSCOcem/config/common.properties file to specify LDAP and system settings.

Step 3 Run /opt/CSCOcem/template/move_template.sh to move all template files from /opt/CSCOcem/template/ to /opt/ipmgr/SRVRS location.

Installing Cisco Cable Manager Client

The Cisco Cable Manager client is required to support more than five simultaneous Cisco Cable Manager user sessions. To enable additional user sessions, the Cisco EMF and Cisco Cable Manager client-only software is installed on a separate UNIX server. The Cisco Cable Manager client is then configured to connect to the Cisco Cable Manager server.


Note Cisco Cable Manager server supports up to five simultaneous users. If more than five simultaneous user sessions are required, a Cisco Cable Manager client can be added to the network to provide an additional five simultaneous user sessions. Expanding on this architecture, additional Cisco Cable Manager clients can be added.

To install the Cisco EMF and Cisco Cable Manager client software, complete the following procedures on the client device:

Step 1 Log in as root user.

Step 2 Insert the Cisco Cable Manager CD-ROM into the CD-ROM drive.

Step 3 Copy the Cisco Cable Manager installation script to a directory on the server:

cp /cdrom/cdrom0/installCableMgr [server_directory]

Step 4 Enter:

./installCableMgr

The Cisco Cable Manager installation script runs and checks the available disk space. The minimum disk space requirements are:

If not enough disk space is available, cancel the installation and ensure adequate disk space is available before running the installation script.

The Cisco Cable Manager installation script also checks if the CEMF, CEMF/EM, and Cisco Cable Manager are already installed. If not already installed, the Cisco Cable Manager installation script will prompt you to select and install these components.

Step 5 When prompted, insert the Cisco Element Manager Framework (CEMF) CD-ROM into the CD-ROM drive.

Step 6 At the Package Installation page, enter C for the CEMF 2.1.4 Patch 4 Client Package (AVcp4.).

The CEMF client patch software is installed.

Step 7 At the Package Installation page, enter CR for the Cisco EMF client-only package (CableMgrc.).

Step 8 When prompted, enter the IP address of the Cisco Cable Manager server to which this client will connect. Each client can connect to only one Cisco Cable Manager server.

Step 9 When prompted, insert the Cisco Event Manager (CEMF/EM) CD-ROM into the CD-ROM drive.

Step 10 At the Package Installation page, enter C for the Cisco EM client-only package.

Step 11 When prompted, insert the Cisco Cable Manager CD-ROM into the CD-ROM drive.

Step 12 At the Add Package page, enter C for the Cisco Cable Manager client-only package.

The complete installation installs the following software on the server:

The following installation log files are stored in the /tmp directory and show a record of the installed components:

These installation log files can be removed whenever the system is rebooted. To avoid losing these files, copy them to another directory for permanent storage.

Uninstalling Cisco Cable Manager

Cisco Cable Manager needs to be uninstalled before the software can be reinstalled or an upgrade version installed.

Uninstalling Cisco Cable Manager Server and Client

To uninstall Cisco Cable Manager server or client:

Step 1 Log in to the Cisco Cable Manager server as root user.

Step 2 Insert the Cisco Cable Manager CD-ROM into the CD-ROM drive and run the uninstallCableMgr script in /cdrom/cdrom0. This script will prompt you when removing the following server or client components:

Step 3 Check the cblMgrUnistall.log file stored in the /tmp directory for a record of the uninstalled components.

To uninstall Cisco IP Manager, refer to the Cisco IP Manager documentation.