cc/td/doc/product/access/acs_serv/5100_sbd
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table of Contents

AT Commands and S-Registers

AT Commands and S-Registers

This appendix contains the following information:

Entering AT Commands

Keep the following in mind when you issue AT commands to a modem:

   When in online mode, the only command the modem recognizes is the escape code (+++), which forces the modem back to command mode in two different ways. If DIP switch 9 is off, the modem disconnects before returning to command mode. If DIP switch 9 is on (factory setting), the modem maintains the connection and enters online-command mode, a state in which it maintains the connection and can also accept com-mands.
ATE1

AT Command Sets

This section contains the following information:

Table C-1 lists the basic modem command set.


Table C-1: Basic Modem Command Set
Command Function

&

See the ampersand command set in Table C-3.

%

See the percent command set in Table C-4

$

Help basic command summary request.

>

Repeat the last command continuously until canceled by pressing any key. If used in a dial string, automated redialing termi-nates after ten attempts.

/ (slash)

Pause for 125 milliseconds.

+++

Escape code, preceded and followed by a guard time of at least one second of no data transmission. The modem responds to +++ by returning to Command mode and doing the following (depending on the setting of DIP switch 9): hangs up and sends NO CARRIER result code (switch 9 off), or retains phone line connection and sends OK result code (switch 9 on)

A

Force answer mode when the modem has not received an incom-ing call.

A/

Re-execute the last issued command one time. A/ does not require the AT prefix or a Return.

A>

Re-execute the last issued command continuously until canceled by pressing any key. Dial strings are re-executed ten times, after which execution terminates. This command does not take the AT prefix or a Return.

AT

Attention: lets the modem know commands are being issued to it. Must precede all other commands except A/, A> and +++.

Bn

Handshake options:

B0

ITU-T V.25 answer sequence. This is the default setting. Also required to answer overseas calls at 1,200 bps and above.

B1

Bell answer tone.

B2

Force Bell 208B mode (synchronous, 4,800 bps).

Cn

Transmitter enabled/disabled.

C0

Transmitter disabled; receive-only condition.

C1

Transmitter enabled.

D

Dial the number that follows and enter Originate mode. Optional parameters:

P

Pulse dial. This is the default setting.

T

Tone dial.

,

Pause for 2 seconds.

;

Return to Command mode after dialing.

"

Dial the letters that follow.

!

Transfer call (flash switch-hook).

W

Wait for second dial tone (with X3 or higher).

@

Wait for an answer (with X3 or higher).

R

Reverse frequencies.

D$

Help dial command summary request.

DL

Dial the last-dialed number.

DL?

Display the number stored in the last-dialed number buffer.

DSn

Dial the phone number stored in NVRAM at position n (n = 0-3).

En

Command mode local echo (display) of keyboard commands ON/OFF. Default = setting of DIP switch 4.

E0

Local echo off.

E1

Local echo on.

Fn

Online local echo of transmitted data on or off. Sometimes referred to as the duplex setting.

F0

Local echo on. Sometimes called half duplex. Modem copies to the screen data it sends to the remote system.

F1

Local echo off. This is the default setting. Sometimes called full duplex. Receiving system may send a remote echo of data.

Hn

On/off hook control.

H0

Hang up (go on hook).

H1

Go off hook. Busy out phone line.

In

Inquiry.

I0

Display product code.

I1

Display results of ROM checksum.

I2

Display results of RAM test.

I3

Display call duration or real time (see Kn).

I4

Display current modem settings.

I5

Display NVRAM settings.

I6

Display link diagnostics.

I7

Display product configuration.

I8

Reserved.

I9

Display standard feature group B settings.

I10

View link security account status.

Kn

Modem clock operation: Call-duration or real-time mode.

K0

Return call duration at ATI3 and ATI6. When modem is offline, returns duration of last call. This is the default setting.

K1

Return actual time at ATI3 and ATI6. Clock is set using ATI3=HH:MM:SS K1.

On

Return online after command execution.

O0

Return online (normal).

O1

Return online and retrain. Use if there were errors in a non-ARQ data transfer.

O0

Return online (normal).

O1

Return online and retrain. Use if there were errors in a non-ARQ data transfer.

P

Pulse dial (default).

Qn

Quiet mode: result codes displayed/suppressed. Default = setting of DIP switch 3.

Q0

Result codes displayed.

Q1

Result codes suppressed (quiet).

Q2

Result codes suppressed in answer mode.

S$

Help S-register summary request.

Sr?

Query contents of register r.

Sr=n

Set S-register value: r is any S-register; n must be a decimal number between 0 and 255.

Sr.b=n

Alternative command for setting bit-mapped registers: r is the bit-mapped register; .b is the bit; n is 0 (off) or 1 (on).

T

Tone dial.

Vn

Return result codes in words or numbers (written/numeric mode). Default = setting of DIP switch 2.

V0

Numeric mode.

V1

Written mode.

Xn

Result code set options. Default = X1, extended set, codes 0-5, 10, and the remaining connect codes in Table C-2.

Z

Software reset. If DIP switch 10 is off, the modem loads the settings in NVRAM. If DIP switch 10 is on, the modem loads the &F0 template, clearing all flow control and high performance settings.

Table C-2 lists the result code options for the Xn command.


Table C-2: Result Code Options for the Xn Command
Result Codes Setting
X0 X1 X2 X3 X4 X5 X6 X7

0/OK

x

x

x

x

x

x

x

x

1/CONNECT

x

x

x

x

x

x

x

x

2/RING

x

x

x

x

x

x

x

x

3/NO CARRIER

x

x

x

x

x

x

x

x

4/ERROR

x

x

x

x

x

x

x

x

5/CONNECT 1200

x

x

x

x

x

x

x

6/NO DIAL TONE

x

x

x

x

7/BUSY

x

x

x

x

x

8/NO ANSWER

x

x

x

x

x

9/RESERVED

10/CONNECT 2400

x

x

x

x

x

x

x

11/RINGING

x

x

x

12/VOICE

x

x

13/CONNECT 9600

x

x

x

x

x

x

x

18/CONNECT 4800

x

x

x

x

x

x

x

20/CONNECT 7200

x

x

x

x

x

x

x

21/CONNECT 12000

x

x

x

x

x

x

x

25/CONNECT 14400

x

x

x

x

x

x

x

43/CONNECT 16800

x

x

x

x

x

x

x

85/CONNECT 19200

x

x

x

x

x

x

x

91/CONNECT 21600

x

x

x

x

x

x

x

99/CONNECT 24000

x

x

x

x

x

x

x

103/CONNECT 26400

x

x

x

x

x

x

x

107/CONNECT 28800

x

x

x

x

x

x

x

Functions

Adaptive dialing

x

x

x

x

x

x

Wait for second dial tone (W)

x

x

x

x

x

Wait for answer (@)

x

x

x

x

x

Fast dial

x

x

x

x

Table C-3 lists the modem ampersand commands.


Table C-3: Ampersand Command Set
Command Function

&$

Help extended command summary request.

&An

Enable/disable additional result code subsets. See the Xn command in Table C-1.

&A0

ARQ result codes disabled.

&A1

ARQ result codes enabled.

&A2

V32 modulation codes enabled.

&A3

Additional error control indicator (LAPM, MNP, or NONE) and data compression type (V42 bis or MNP Level 5). This is the default setting.

&Bn

Serial port rate.

&B0

Serial port rate switches to follow connection.

&B1

Serial port rate remains fixed at the computer setting. Allowable rates are 115.2, 57.6, 38.4, 19.2, 9.6kbps and 4,800, 2,400, 1,200, and 300 bps. This is the default setting.

&B2

In answer mode, shift to the fixed serial port rate for ARQ calls, follow the connection rate for non-ARQ calls.

&Cn

Carrier Detect (CD) signal, modem to computer. The setting of DIP switch 6 determines CD operations at power-on and reset.

&C0

CD override (CD always on).

&C1

Modem sends CD signal when it connects with another modem, drops CD on disconnect.

&Dn

Data Terminal Ready (DTR) signal, computer to modem. DIP switch 1 sets DTR operations at power-on and reset.

&D0

DTR override (DTR always on).

&D1

If issued before connecting, the modem enters online command mode during a call when DTR is toggled. &D1 functions similarly to the escape code (+++). Return online with ATO, or hang up with ATH.

&D2

Normal DTR. Terminal must send DTR for modem to accept com-mands.

&Fn

Load one of four (ROM) templates into RAM (n = 0, 1, 2, or 3). See the section "User-Programmable Defaults" later in this appendix.

&Gn

Guard tone for 2,400/1,200 bps calls from overseas.

&G0

No guard tone (U.S., Canada). This is the default setting.

&G1

550 Hz guard tone (some European countries).

&G2

1800 Hz guard tone. Requires B0 setting.

&Hn

Transmit data flow control.

&H0

Flow control disabled.

&H1

Hardware (Clear to Send) flow control. This is the default setting.

&H2

Software (XON/XOFF) flow control.

&H3

Hardware and software flow control.

&In

Received Data software flow control.

&I0

Flow control disabled. This is the default setting.

&I1

XON/XOFF to local modem and remote computer.

&I2

XON/XOFF to local modem only.

&I3

Host mode, Hewlett-Packard protocol.

&I4

Terminal mode, Hewlett-Packard protocol.

&I5

Same as &I2 in ARQ mode. In non-ARQ mode, XON/XOFF to remote modem for link flow control.

&Kn

Data compression.

&K0

Disabled.

&K1

Auto enable/disable. This is the default setting. Disabled if modem is set to &B0 and serial port rate switches to match link rate.

&K2

Enabled regardless of &Bn setting.

&K3

Selective data compression—MNP Level 5 disabled.

&Ln

Normal/leased phone line.

&L0

Normal phone line. This is the default setting.

&L1

Leased line; enables the modem to reconnect.

&Mn

Error Control (ARQ).

&M0

Normal mode, error control disabled.

&M1

Online synchronous mode without V.25 bis.

&M2

Reserved.

&M3

Reserved.

&M4

Normal/ARQ mode. This is the default setting. Normal connection if ARQ connection cannot be made.

&M5

ARQ mode. Modem hangs up if ARQ connection cannot be made.

&M6

V.25 bis mode, using a character-oriented Binary Synchronous communications protocol.

&M7

V.25 bis synchronous mode, using HDLC Protocol.

&Nn

Link rate variable or fixed. With fixed link rate, modem hangs up if called or calling modem is operating at a different rate.

&N0

Variable link operations. Negotiates highest possible link rate with remote modem. This is the default, and the recommended setting.

&N1 300 bps

&N2 1200 bps

&N3 2400 bps

&N4 ,800 bps

&N5 7200 bps

&N6 9600 bps

&N7 12 kbps

&N8 14.4-kbps

&N9 16.8-kbps

&N10 19.2-kbps

&N11 21.6-kbps

&N12 24 kbps

&N13 26.4-kbps

&N14 28.8-kbps

&Pn

Pulse dialing make/break ratio.

&P0

U.S./Canada make/break ratio. This is the default setting.

&P1

U.K. make/break ratio.

&Rn

Received data hardware (RTS) flow control.

&R0

Delay between DTE's RTS signal and the modem's CTS response; duration set by S26.

&R1

Ignore RTS.

&R2

Received data sent to computer only when RTS is high; used only if computer supports RTS. This is the default setting.

&Sn

Data Set Ready (DSR) operations.

&S0

DSR override, always on. This is the default setting.

&S1

Modem sends computer a DSR signal when it detects a modem tone on the phone line.

&S2

On loss of carrier, modem sends computer a pulsed DSR signal; Clear to Send (CTS) follows Carrier Detect (CD).

&S3

This is the same as &S2, but without CTS following CD.

&S4

DSR follows CD.

&S5

CTS follows CD, with DSR normal.

&Tn

Modem testing. The following analog tests (&T1 and &T8) are only valid for the quad analog modem and the quad analog/digital configured for analog mode.

&T0

End test.

&T1

Initiate analog loopback testing.

&T2

Reserved.

&T3

Initiate local digital loopback testing.

&T4

Grant remote digital loopback. This is the default setting.

&T5

Prohibit remote digital loopback.

&T6

Initiate remote digital loopback testing.

&T7

Initiate RDL with self-test and error correction.

&T8

Initiate analog loopback with self-test and error correction.

&T9

Generates a tone to verify the digital signal processor's ability to generate analog tones and T1 line diagnostics. Command syntax is AT&T8=Freq,Amp, where the Frequency can be from 300 to 4,000 Hz and the amplitude from -40 to 0 dBm. Press any key to cancel the tone testing.

&T10

Sets the modem to receive analog test tones. This test reports the received tones in frequency and amplitude to the DTE interface on a five-second basis (either to a connected terminal interface or through an SNMP manager). Press any key to cancel the tone testing.

&W

Write current settings to NVRAM.

&Xn

Synchronous clock source. The &X1 and &X2 commands are only valid for analog modems; they are not supported for digital T1 applications.

&X0

Modem's transmit clock. This is the default setting.

&X1

DTE's transmit clock.

&X2

Modem's receiver clock.

&Yn

Break handling. Destructive breaks clear the buffer; expedited breaks are sent immediately to the remote system. Under data compression, destructive breaks cause both modems to reset their compression tables.

&Y0

Destructive, don't send break.

&Y1

Destructive, expedited. This is the default setting.

&Y2

Nondestructive, expedited.

&Y3

Nondestructive, unexpedited; modem sends break in sequence with data received from computer.

&Zn=L

Write the last dialed number to NVRAM at position n (n = 0, 1, 2, or 3).

&Zn=s

Write the following dial string (s) to NVRAM at position n (n = 0, 1, 2, or 3).

&Zn?

Display the phone number stored in NVRAM at position n (n = 0, 1, 2, or 3).

Table C-4 lists the percent commands.


Table C-4: Percent Command Set

%$

Help percent command summary request.

%A=

Set up the host security account. The %A= command is automatically written to NVRAM and does not require an &W command.

You must specify two fields:

  • The account password.

  This identifies the host security account. It can be up to eight characters (ASCII characters 32-127) and is case sensitive.
  • Prompt for phone number (Y/N).

  Y indicates that the host modem will prompt the remote user to enter a phone number; the host modem disconnects and then dials back. N indicates that no prompt will be made.
  The fields are entered after the equal sign, separated by a comma, as in the following example for an account with the password BILL and dialback prompting enabled.

AT%A=BILL,Y<Enter>

%Bn

Configure the serial port rate during a remote access session.

%B0 110 bps

%B1 300 bps

%B2 600 bps

%B3 1200 bps

%B4 2400 bps

%B5 4800 bps

%B6 9600 bps

%B7 19200 bps

%B8 38400 bps

%B9 57600 bps

%B10 = 115200 bps

%Cn

Configuration control during remote access session.

%C0

Defer configuration. This is the default setting. Configu-ration changes are deferred until the call is ended, and take effect for subse-quent connections. This command does not have to be entered; it is the default unless one of the following %C values is entered.

%C1

Restore configuration. Use this command to cancel any configuration changes made during remote access and restore the original configuration. However, commands that have been written to NVRAM (with &W) will not be restored to their previous settings. Additionally, if immediate config-uration changes are forced (with %C2), those changes cannot be reversed with %C1.

%C2

Execute configuration. Forces configuration changes to take effect immediately, during the current connection. Do not force immediate configuration changes unless absolutely necessary, as this may result in an unreliable connection or even a loss of connection.

%CNn=s

Sets the Carrier Access Code number, where n is a position in NVRAM (from 1-3) and s is a numeric string containing from 1 to 10 digits. This code allows programming of Dialed Number Indicate Service or Automatic Number Indicate, a service offered by the telephone company.

%CIn=s

Sets the carrier access code-associated initialization string, where n is a position in NVRAM (1, 2, 3, or 4) and s is a configuration string of up to 30 characters. Do not include the AT attention prefix in the initialization string.

%CNn=s and %CIn=s allow you to configure a stored initialization string feature in the quad modems. First, define up to three full or partial telephone numbers that may be dialed to access the modem, using the AT%CNn=s command. An initialization string (without the AT command prefix) can then be associated with the carrier access code num-ber by using the AT%CIn=s command. Four initialization strings may be stored: three of them to match the carrier access code of a specified carrier access code number, and the fourth to be executed if the modem receives an unknown carrier access code (no full or partial match).

When a call comes in, the quad modem compares the number dialed against the defined carrier access code numbers. An initialization string is then used to configure the modem to answer the call.

The carrier access code numbers defined, with their associated initialization strings, can be viewed by entering the ATI9 command.

The quad modem identifies the carrier access code on incoming calls by returning special RING result codes, as follows.



  • o DNIS or ANI information received: RING (normal).

  • Only DNIS information received: RING/5 (where 5 is the DNIS number).



  • NI and DNIS information received: RING/5/5551212 (where 5 is the DNIS and 5551212 is the ANI).

  • Only ANI information received: RING//5551212 (where two slashes indicate no DNIS, and 5551212 is the ANI).

The CAC associated with the last call received is displayed on the current settings screen (obtained by issuing the command ATI4), as follows:

LAST DNIS #: nn. .nn

or

LAST ANI #: nn..nn

%Dn

Toggle between analog and digital modes (quad analog/digital modems only).

%D0

Analog mode. A digital only modem returns an error if sent this command.

%D1

Digital mode. An analog-only modem returns an error if sent this command. When set to %D1, the modem displays the message "DCE=Digital (DS0)" on the I4 command screen to indicate that the modem has been configured for digital and is linked with the T1 NAC. If no T1 link has been established, the modem displays the message "DCE=Digital (DS) ?" It may take up to 30 seconds to establish a T1 link. If this message persists, there is either no T1 module is present, or there is a hardware problem.

%E=n

Use the %E=n command to edit the link security configuration, where n = 1, 2, 3, or 4.

%E=1

Erase local access password.

%E=2

Erase autopass password.

%E=3

Erase password account.

%E=4

Erase account status information.

%Fn

Configure the data format during a remote access session.

%F0

No parity, 8 data bits.

%F1

Mark parity, 7 data bits.

%F2

Odd parity, 7 data bits.

%F3

Even parity, 7 data bits.

%L=

Set the local access password for link security.

%Pn

Assign remote access password.

%P0

Create password that allows viewing privileges only.

%P1

Create password that allows viewing and con-figuration privileges.

%Pn=s

Set the following password string (s) at position n (n = 0 or 1).

%Pn?

Display the password stored at position n (n = 0 or 1).

%S=

Access link security settings by entering the local access password.

%T

Tone recognition. Enables modem, when off hook, to detect the tone frequencies of dialing modems.

%V=

Set link security autopass password for both the host and remote modem.

User-Programmable Defaults

You can create your own default configuration and store it in NVRAM using the &W command described in the chapter "Quad Modems." As long as DIP switch 10 is off when you power on the modem, your defaults are loaded into the modem's NVRAM. You can view the NVRAM contents with the ATI5 command.

This section includes information about options you can store in NVRAM, including S-register settings. The modem has four factory setting templates (&F0-&F3). By default, the first time the modem is turned on, it loads the settings stored in NVRAM, which are the same as the settings in factory template 1 (&F1), listed in Table C-5.

The following command substitutes several user-defined defaults for factory settings. The modem also stores the rate, word length, and parity that your software is set to when it receives the AT command prefix:

ATTX6&M5&W

Table C-5 through Table C-8 list the settings of each configuration template plus the S-registers that can be stored in NVRAM.

The modem is shipped with DIP switch 10 off, so when it is powered on it loads the settings from NVRAM. Until these settings are changed, they are they same as the settings permanently stored in configuration template 1 (&F1). You can alter any of these settings, create your own power-on defaults, and then save them using the &W command.


Table C-5: Hardware Flow Control Default Template
NVRAM Options Setting Description

Handshake option

B0

ITU-T answer sequence

Error control/sync

&M4

Normal/error control

Data compression

&K1

Enabled

Transmit data flow control

&H1

Hardware flow control enabled

Rec'd data hardware flow control

&R2

Enabled

Rec'd data software flow control

&I0

Disabled

Serial port rate select

&B1

Serial port rate fixed higher than connect rate

Link rate select

&N0

Variable

Result code subset

X7

Extended. Includes all codes except

Protocol response codes

&A3

Full protocol codes

Tone or pulse dialing

P

Pulse dial

Online local echo

F1

Disabled

Remote digital loopback

&T4

Grant remote digital loopback

Normal/leased/cellular line

&L0

Normal phone line

Data set ready operations

&S0

Override enabled

Break handling

&Y1

Clear buffer, send immediately

Stored telephone number

&Z0-3=0

Blank

Pulse dial make/break ratio

&P0

U.S. and Canada

Guard tone

&G0

U.S. and Canada

Word length

8

Parity

0

None

DTE rate

19.2 kbps

-

Word length, parity, and the DTE rate are detected by the modem from the AT prefix of the &W com-mand that writes your defaults to NVRAM. Set your software to the desired word length, parity, and serial port rate defaults before sending the modem the AT . . . &W string.

The &F2 and &F3 factory setting templates (see Table C-6) are similar to the &F1 template, with the exception of the commands that are highlighted in bold.


Table C-6: &F2 Software Flow Control Default Template
NVRAM Options Setting Description

Handshake option

B0

ITU-T answer sequence

Normal/error control/sync

&M4

Normal/error control

Data compression

&K1

Enabled

Transmit data flow control

&H2

Software flow control enabled

Rec'd data hardware flow control

&R1

Disabled

Rec'd data software flow control

&I2

Enabled

Serial port rate select

&B1

Serial port rate fixed higher than connect rate

Link rate select

&N0

Variable

Result code subset

X7

Extended. Includes all codes except VOICE

Protocol response codes

&A3

Full protocol codes

Tone and pulse dialing

P

Pulse dial

Online local echo

F1

Disabled

Remote digital loopback

&T4

Grant remote digital loopback

Normal/leased/cellular line

&L0

Normal phone line

Data set ready operations

&S0

Override enabled

Break handling

&Y1

Clear buffer, send immediately

Stored telephone number

&Z0-3=0

Blank

Pulse dial make/break ratio

&P0

U.S. and Canada

Guard tone

&G0

U.S. and Canada

Word length

8

Parity

0

None

DTE rate

19.2 kbps

-

Word length, parity, and the DTE rate are detected by the modem from the AT prefix of the &W com-mand that writes your defaults to NVRAM. Set your software to the desired word length, parity, and serial port rate defaults before sending the modem the AT . . . &W string.

If DIP switch 10 is on when the modem is powered on, or you load factory template 0 (&F0), the settings in Table C-7 take effect.


Table C-7: &F3 Software Flow Control Default Template
NVRAM Options Setting Description

Handshake option

B0

ITU-T answer sequence

Normal/error control/sync

&M4

Normal/error control

Data compression

&K1

Enabled

Transmit data flow control

&H0

Disabled

Rec'd data hardware flow control

&R1

Disabled

Rec'd data software flow control

&I0

Disabled

Serial port rate select

&B0

Detect from AT command: then follow connection rate

Link rate select

&N0

Variable

Result code subset

X1

Basic

Error-control response codes

&A1

Enabled

Tone/pulse dialing

P

Pulse dial

Online local echo

F1

Disabled

Remote digital loopback

&T4

Grant remote digital loopback

Normal/leased/cellular line

&L0

Normal phone line

Data set ready operations

&S0

Override enabled

Break handling

&Y1

Clear buffer, send immediately

Stored telephone number

&Z0-3=0

Blank

Pulse dial make/break ratio

&P0

U.S. and Canada

Guard tone

&G0

U.S. and Canada

Word length

7

Parity

1

Even

DTE rate

9600 bps

-

Word length, parity, and the DTE rate are selected by the modem from the AT prefix of the &W com-mand that writes your defaults to NVRAM. Set your software to the desired word length, parity, and serial port rate defaults before sending the modem the AT . . . &W string.

S-Register NVRAM Options

Table C-8 lists the S-registers for which values can be stored in NVRAM, along with the factory settings.


Table C-8: S-Register Factory Settings
NVRAM S-Register Option Register Setting

Number of rings to answer, ASCII decimal

S0

1

Escape code character, ASCII decimal

S2

43

Carriage return character, ASCII decimal

S3

13

Line feed character, ASCII decimal

S4

10

Backspace character, ASCII decimal

S5

8

Dial wait-time, sec

S6

2

Carrier wait-time, sec

S7

60

Pause during dial/before repeat, sec

S8

2

Carrier detect time, 1/10th sec

S9

6

Carrier loss wait-time, 1/10th sec

S10

7

Tone duration, spacing, ms

S11

70

Escape code guard time, 1/50th sec

S12

50

Bit-mapped

S13

0

Bit-mapped

S25

0

Inactivity/hang up timer, min.

S19

0

Received break length, 10-ms units

S21

10

XON character, ASCII decimal

S22

17

XOFF character, ASCII decimal

S23

19

Duration of pulsed DSR, 20-ms units

S24

150

Minimum DTR recognition time, 10-ms units

S25

5

Delay between RTS, CTS response (sync oper.)

S26

1

Bit-mapped

S27

0

V.32 handshake time, 10-ms units

S28

8

V.21/V.23 fallback timer, 1/10th sec

S29

20

Unusual software compatibility

S31

0

Bit-mapped

S33

0

Bit-mapped

S34

0

Unusual software incompatibility

S37

0

Delay ARQ-call hang-up when DTR drops, sec.

S38

0

Allowable login attempts

S41

0

Remote access ASCII characters

S42

126

Remote guard time, 1/50th sec

S43

200

Re-establish leased-line connect, sec

S44

15

Bit-mapped

S47

0

Additional answer tone duration, 1/10 sec

S49

16

Billing delay period, 1/50 sec

S50

100

Bit-mapped

S51

0

Bit-mapped

S53

0

Bit-mapped

S54

0

Bit-mapped

S55

0

Bit-mapped

S56

0


hometocprevnextglossaryfeedbacksearchhelp