cc/td/doc/product/access/acs_serv/5100_sbd
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table of Contents

Technical Specifications

Technical Specifications

This appendix contains technical specifications for the following Cisco Access Server 5100 components:


Table A-1: Chassis and Power Supply Specifications
Specification Description

Access Server 5100 chassis capacity

Up to 17 front-loaded NACs, and their associated rear-loaded NICs. Two power supplies (both are required)

Certification

Complies with FCC Part 15 Class A EMI/RFI require-ments; complies with FCC Part 68 for nationwide tele-phone systems; listed by Underwriters' Laboratories (UL), approved by the Canadian Standards Association (CSA), and is Department of Communications (DOC) certified

Power requirements

DC power supply nominal -48 VDC (-42 VDC to -60 VDC) with respect to ground

AC power supply nominal 120 V (90-132 VAC) @ 47-63 Hz, or strap-selectable nominal 240 V (180-264 VAC)
@ 47-63 Hz

Power supply output (maximum)

330 W
45A @ +5.2V
2A @ -5 V
3.5A @ +12.2V
3.5A @ -12.2V

Power supply input (maximum)

470W
1604 Btus
4A (DC)
10A (DC)

Operating environment

Temperature: 32-104oF (0-40oC)
Relative humidity: 0-95% noncondensing


Table A-2:
AS51 NAC and NIC
Specification Description

Power requirements
(maximum)

4A @ +5 VDC, 6.75W
55 mA @ -5 VDC, 275 mW
50 mA @ +12 VDC, 600 mW
50 mA @ -12 VDC, 600 mW

Operating environment

Temperature: 32-104oF (0-40o)
Relative humidity: 0-95% noncondensing

Dimensions (L x H)

NAC: 12.45 x 6.4" (31.62 x 16.26 cm)
NIC: 4.85 x 6.4" (12.32 x 16.26 cm)

Certification

Complies with FCC Part 15, UL-listed, CSA-approved


Table A-3:
Quad Modem NAC and NIC
Specification Description

Power requirements
(maximum)

1.35A @ +5 VDC, 6.75W
55 mA @ -5 VDC, 275 mW
50 mA @ +12 VDC, 600 mW
50 mA @- 12 VDC, 600 mW

Operating environment

Temperature: 32-104oF (0-40oC)
Relative humidity: 0-95% noncondensing

Dimensions (L x H)

NAC: 12.45 x 6.4" (31.62 x 16.26 cm)
NIC: 4.85 x 6.4" (12.32 x 16.26 cm)

Certification

Complies with FCC Part 15, UL-listed, CSA-approved

Receive sensitivity

-44 dBm +2 dBm

Transmit level

-9 dBm maximum

Transmitter frequency tolerance

.01%


Table A-4:
Specification Description

Power requirements

1.5A @ 5 VDC
0.1 A @ 12 VDC
5W

Dimensions (L x H)

NAC: 12.45 x 6.4" (31.62 x 16.26cm)
NIC: 4.85 x 6.4" (12.32 x 16.26 cm)

Heat

17 Btus

Operating environment

Temperature: 32-104oF (0-40oC)
Relative humidity: 0-95% noncondensing

T1 NAC and NIC

Table A-5:
Network Management NAC
Specification Description

Power requirements (maximum)

3.5A @ +5 VDC
20 mA @ -5 VDC
50 mA @ +12 VDC
50 mA @ -12 VDC

Operating environment

Temperature: 32-104oF (0-40oC)
Relative humidity: 0-95% noncondensing

Dimensions (L x H)

12.45 x 6.4" (31.62 x 16.26 cm)

Certification

Complies with FCC Part 15 Class A, FCC Part 68, UL-listed, CSA-approved, and DOC-certified


Table A-6:
Network Management Ethernet NIC
Specification Description

Power requirements

1.5A @ +5 VDC
50 mA @ +12 VDC
50 mA @ -12 VDC

Operating environment

Temperature: 32-104oF (0-40oC)
Relative humidity: 0-95% noncondensing

Dimensions (L x H)

4.85 x 6.4" (12.32 x 16.26 cm)

Certification

Complies with FCC Part 15 Class A, FCC Part 68, UL-listed, CSA-approved, and DOC-certified


hometocprevnextglossaryfeedbacksearchhelp
Posted: Tue Oct 1 04:01:35 PDT 2002
All contents are Copyright © 1992--2002 Cisco Systems, Inc. All rights reserved.
Important Notices and Privacy Statement.