cc/td/doc/product/access/acs_mod/cismc
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table of Contents

Upgrading CSC-SCI Cards from Microcode
Version 1.0, 1.1, 1.2 or 1.3 to Version 1.4 or 1.4A

Upgrade Prerequisites
Preventing Electrostatic Discharge Damage
Opening the Chassis
Upgrading the SCI Card

Upgrading CSC-SCI Cards from Microcode
Version 1.0, 1.1, 1.2 or 1.3 to Version 1.4 or 1.4A


Product Numbers: MC-SCI-V1.4= and MC-SCI-V1.4A=

This publication describes the microcode upgrade procedures for the Serial-Port Communications Interface (SCI) cards to microcode Version 1.4 or 1.4A. To perform the upgrade, you will replace up to 17 integrated circuit components. The new components are shipped with the SCI Microcode Version 1.4 and 1.4A kits. This upgrade is for SCI cards currently at Microcode Version 1.0, 1.1, 1.2 or 1.3. The SCI card should be a Rev. 2 (type 2.0).

Upgrade Prerequisites

Verify that your card type and microcode version. Use the show controller mci command.
The first line displayed contains the controller type and the microcode version. Following is sample output indicating card type 2.0 (Rev. 2) and Microcode Version 1.3:

 MCI X, controller type 2.0, microcode version 1.3



Figure 1   SCI Card Components

For the SCI microcode upgrades, the following statements apply:

Preventing Electrostatic Discharge Damage

Electrostatic discharge (ESD) is a discharge of stored static electricity that can damage equipment and impair electrical circuitry. It occurs when electronic components are improperly handled and can result in complete or intermittent failures.

Following are guidelines for preventing ESD damage:


Caution

For safety, periodically check the resistance value of the antistatic strap. The measurement should be within the range of 1 and 10 Mohms.


Opening the Chassis

You must remove the front access panel to access the cards in the card cage. You must remove the top cover to access the other chassis components. The following procedures include instructions for both. Use the procedure that applies to your chassis type.

Tools Required

The following tools are required for accessing the chassis interior:

A-Type Chassis Access Procedure

Following is the procedure for accessing the A-type chassis interior.


Warning

Before accessing the chassis interior, turn OFF power to the chassis and unplug the power cord because hazardous voltages may exist in or near the power supply. Use extreme caution when working near the power supply.



Step 1   Turn OFF power to the chassis and unplug it from AC power.

Step 2   If the chassis is rack mounted, disconnect all external cables from the chassis rear panel. Note where these cables were connected, for reinstallation.

Step 3   Remove the chassis from the rack and transfer it to a desktop or work table.

Step 4   If you will need to handle any electronic components (cards, and so forth), attach appropriate ESD protection and attach the AC power cord, but to prevent a shock hazard, make certain the chassis power is OFF.

Step 5   To access cards in the card cage, loosen the two thumbscrews and remove the front panel from the chassis. (See Figure 2.) If you wish to access cards in the card cage only, skip the next step.

Step 6   To access other system components, locate and remove the seven No. 1 Phillips screws securing the top cover. (See Figure 2.) Set the top cover and screws aside.



Figure 2   Chassis Front and Top Panels

Note      To reassemble the chassis, reverse all steps.


MGS Chassis Access Procedure

Following is the procedure for accessing the MGS chassis interior.


Warning

Before accessing the chassis interior, turn OFF power to the chassis and unplug the power cord because hazardous voltages may exist in or near the power supply. Use extreme caution when working near the power supply.



Step 1   Turn OFF power to the chassis and unplug it from AC power.

Step 2   If the chassis is rack mounted, disconnect all external cables from the chassis rear panel. Note where these cables were connected, for reinstallation.

Step 3   Remove the chassis from the rack and transfer it to a desktop or work table.

Step 4   If you need to handle any electronic components (cards, and so forth) attach appropriate ESD protection and attach the AC power cord, but to prevent a shock hazard, make certain the chassis power is OFF.

Step 5   To access the cards in the card cage, locate the three flat-blade screws that secure the card cage access panel. (See Figure 3.) These screws are located on the top of the MGS chassis access panel.

Step 6   Using the flat-blade screwdriver, turn each of these screws 1/4 to 1/2 turn counterclockwise until the screw pops up.

Step 7   Using the No. 2 Phillips screwdriver, loosen the three screws at the bottom edge of the card cage cover. (Do not remove these screws completely.) Carefully remove the card cage cover and set it aside.

Step 8   To access the other chassis components, use the No. 1 Phillips screwdriver to remove the 14 screws that secure the top cover of the MGS chassis. (See Figure 3.) Set the top cover aside.



Figure 3   Screw Locations on the MGS Chassis Exterior—Side View

Note      To reassemble the chassis, reverse all steps.


Upgrading the SCI Card

To perform this procedure, you need some or all of the following:


Caution

To prevent ESD damage, refer to the section "Preventing Electrostatic Discharge Damage."


Following is the procedure for upgrading the SCI card. Before beginning, refer to Figure 1 and locate the components you will replace. The component sockets and the part numbers of both the old and new (replacement) microcode versions are listed in Table 1.


Step 1   Turn OFF power to the system power, but to channel ESD voltages to ground, do not disconnect the power cord.

Step 2   Attach an ESD-preventive wrist strap.

Step 3   Open the chassis using one of the procedures in the section "Opening the Chassis."

Step 4   Put on the wrist strap provided with the upgrade kit, or use your own grounding strap. Attach the equipment end to an unpainted area on the chassis.

Step 5   Disconnect the internal ribbon cables that are attached to the front of the SCI card. If other cables (to other cards) are in front of the SCI card and prevent you from removing it, note the card and port locations of each before disconnecting them (to avoid misrouting cables when you reinstall the card).

Step 6   Use your thumbs to pull the ejector tabs out and away from the card edge to loosen it; then pull the card out of its slot. Place the card on an antistatic mat.

Step 7   Locate the components to be replaced. (Refer to Figure 4 and Table 1.)

Step 8   Remove each of the old components with the chip extractor. If one is not available, use a flat-blade screwdriver to gently pry each components out of its socket.

Step 9   Insert the new components into the appropriate sockets.

Step 10   Align the notch on the component with the notch on the corresponding socket.
(See Figure 4.)



Figure 4   SCI Card Components

Table 1   SCI Card Replacement Component s

Socket  Versions 1.0  Versions 1.1  Versions 1.2  Version 1.3 and 1.3A  Version 1.4  Version 1.4A 

U607

13/220A

13/220A

17-0437

17-0437-01 U607

17-0437-02 U6071

17-0437-02 U6071

U504

13/221A

13/221A

17-0438

17-0438-01 U504

17-0438-02 U504

17-0438-02 U504

U505

13/222A

13/222A

17-0439

17-0439-01 U505

17-0439-02 U505

17-0439-02 U505

U506

13/223A

13/223A

17-0440

17-0440-01 U506

17-0440-02 U506

17-0440-02 U506

U404

13/224A

13/224A

17-0441

17-0441-01 U404

17-0441-02 U404

17-0441-02 U404

U405

13/225A

13/225B or 17-0442

17-0442(B)

17-0442-02 U405

17-0442-03 U405

17-0442-03 U405

U406

13/226A

13/226B or 17-0443

17-0443(B)

17-0443-02 U406

17-0443-03 U406

17-0443-03 U406

U304

13/227A

13/227A

17-0444

17-0444-01 U304

17-0444-02 U304

17-0444-02 U304

U305

13/228A

13/228A

17-0445

17-0445-01 U305

17-0445-02 U305

17-0445-02 U305

U306

13/229A

13/229A

17-0446

17-0446-01 U306

17-0446-02 U306

17-0446-02 U306

U204

13/230A

13/230A

17-0447

17-0447-01 U204

17-0447-02 U204

17-0447-02 U204

U205

13/231A

13/231A

17-0448

17-0448-01 U205

17-0448-02 U205

17-0448-02 U205

U213

13/107A

13/107

13/107

17-0675-01 U213, 17-0675B-01 U213
or 13-107B-01 U213

17-0675-01 U2132, 17-0675B-01 U213
or 13-107B-01 U213

-

U708

R68561P

R68561P

R68561P

R68561AP-01 U708

R68561AP-01 U7083

-

U709

R68561P

R68561P

R68561P

R68561AP-01 U709

R68561AP-01 U709

-

U908

R68561P

R68561P

R68561P

R68561AP-01 U908

R68561AP-01 U908

-

U909

R68561P

R68561P

R68561P

R68561AP-01 U909

R68561AP-01 U909

-

The new component numbers contains a six-digit part number, a two-digit version identifier, and a socket location number. For example, the component number 17-0437-01 U607 contains part number 17-0437, version identifier 02 (which corresponds to Microcode Version 1.4 or 1.4A), and socket location U607.

The 17-0675 bus-timing PAL is required only if you have upgraded from a CSC/2 to a CSC/3 or CSC/4 processor, along with this MCI microcode upgrade. If your system used a CSC/3 or CSC/4 before the MCI microcode upgrade, the 17-0675 PAL component is not required.

These Rockwell components are used only for the MC-SCI-1.4 upgrade. The MC-SCI-V1.4A upgrade does not require these Rockwell components.

Step 11   Be careful not to bend or crush any of the pins when inserting the new components. If any pins become bent, use needlenose pliers to straighten the pins; then carefully reinsert the component. If a component is installed backwards when power is turned ON, the component will be damaged. Contact a customer service representative for a replacement.

Step 12   When all of the components have been replaced, reinsert the card, reconnect the internal cables, replace the access panel, and restart the system.

Step 13   Enter the EXEC command show controller mci. The first line of the display for each installed SCI card should be as follows:

MCI X, controller type 2.0, microcode version 1.4

Step 14   Using the display from the show controller mci command to verify that the microcode version is 1.4.

This completes the microcode upgrade procedure.


hometocprevnextglossaryfeedbacksearchhelp
Posted: Thu Nov 6 16:11:03 PST 2003
All contents are Copyright © 1992--2003 Cisco Systems, Inc. All rights reserved.
Important Notices and Privacy Statement.