This release note applies to software version 3.2 for Cisco 11000 Series Secure Content Accelerators. The note supplements information found in the Cisco 11000 Series Secure Content Accelerator Configuration Guide distributed with version 3.1 of the firmware.
The Cisco 11000 Series Secure Content Accelerator is compatible with all Cisco content switchesthe Cisco LocalDirector, the Catalyst Content Switching Module, and the Cisco CSS 11000 Series Content Services Switches.
The following sections are presented in this note:
The CD-ROM contains the following resources:
The table below shows the configuration manager software versions appropriate for each operating system.
Operating System | Software Version |
---|---|
Red Hat Linux | 3.2 |
Windows NT 4 | 3.2 |
Windows 2000 | 3.2 |
Solaris Sparc | 3.2 |
The FW directory contains the firmware flash image for the Cisco 11000 Series Secure Content Accelerator. Use the flash image to update a 3.x version of the firmware.
The CSS 11000 Secure Content Accelerator configuration utility, cscacfg, is only compatible with devices that have the same software version. Devices with a different firmware version must be configured using the configuration manager that matches the firmware on the device.
Release version refers to the CD software release and not to the firmware or configuration manager versions. Any reference to firmware or the configuration manager in these release notes or documentation is to CD software release version. The commands show version and show device display both the cscacfg (configuration manager) and firmware versions as well as the software release version. The end number of the text returned shows the build date and time stamp in the following format:
|Year|Month|Day|Time Stamp|
For example:
|2001|08|03|1046|
The fw directory contains the firmware image of the Cisco 11000 Series Secure Content Accelerator. This file is described in the following table.
Filename | Description |
---|---|
css-sca-2fe-k9.phz | Image of the 3.2 software release. This image is used only to reflash the device and update previous versions of the device. |
Use the following instructions to upgrade the firmware on the device and the remote configuration manager software. Please read the entire document before proceeding with the flash upgrade.
1. Copy the firmware image to an HTTP, FTP, or TFTP server on the same LAN as the Secure Content Accelerator. An FTP URL is preferable.
2. Connect to the Secure Content Accelerator via a serial management session at 9600 baud.
3. Check the existing firmware version using the show device command. The returned text should contain "MaxOS 3.1.0".
4. Enter these commands to load the firmware image, where protocol is HTTP, FTP, or TFTP; serverip is the IP address of the server; and path is the path to the firmware image file. (If using a Windows operating system, use back slashes instead of forward slashes.)
enable
copy to flash protocol://serverip/path/css-sca-2fe-k9.phz
reload
5. Wait for several minutes for the device to reload and reboot.
6. Check the firmware version by using the show device command. The returned text should contain "MaxOS 3.2.0".
7. Continue with configuration as desired.
1. Copy the firmware image to an HTTP, FTP, or TFTP server on the same LAN as the Secure Content Accelerator. An FTP URL is preferable.
2. Connect to the Secure Content Accelerator using the IP address previously assigned to it.
3. Check the existing firmware version using the show device command. The returned text should contain "MaxOS 3.1.0".
4. Enter these commands to load the firmware image, where protocol is HTTP, FTP, or TFTP; serverip is the IP address of the server; and path is the path to the firmware image file. (If using a Windows operating system, use back slashes instead of forward slashes.)
enable
copy to flash protocol://serverip/path/css-sca-2fe-k9.phz
reload
5. You will see a status message stating the connection to the device was lost. Wait for several minutes for the device to reload and reboot. The telnet connection to the device is lost.
6. Reconnect to the device using a telnet management session.
7. Check the firmware version by using the show device command. The returned text should contain "MaxOS 3.2.0".
8. Continue with configuration as desired.
Follow these instructions for downgrading using a remote CLI management session.
1. Copy the firmware image to the computer from which you configure the Secure Content Accelerator.
2. Open the existing configuration manager application (cscacfg) using the desktop shortcut or the Start button (Windows) or entering cscacfg at a Unix or Linux prompt.
3. Display all Secure Content Accelerators found by the configuration manager by entering the show device list command. If the device is not listed, use the discover command.
4. The following commands assume only one device has been discovered by the configuration manager. If more than one Secure Content Accelerator is listed, use the on form of the command to specify the desired device.
Note You can set the on-prefix to direct commands to a single device. |
attach
enable
5. If only one Secure Content Accelerator is listed, use the show device command. If more than one device is listed, use the command on devname show device, where devname is the name of the device. The returned text should contain "MaxOS 3.1.0".
6. Enter these commands to load the firmware image, where path is the path to the firmware image file. (If using a Windows operating system, use back slashes instead of forward slashes.)
copy to flash path/css-sca-2fe-k9.phz
reload
7. Quit the configuration manager. If you wish to continue with configuration via the remote configuration manager, you must remove the 3.1.0 version and install the 3.2.0 version as described in "Remote Configuration Manager Replacement" below. Make sure you upgrade all 3.1.0 devices before removing the 3.1 version of the configuration manager.
8. To continue configuring the device with the 3.2.0 remote configuration manager, open the application (cscacfg) using the desktop short cut or the Start button (Windows) or entering cscacfg at a Unix or Linux prompt.
9. Display all Secure Content Accelerators found by the configuration manager by entering the show device list command. If the device is not listed, use the discover command.
10. Attach to the device and check the firmware version using the show device command. The returned text should contain "MaxOS version 3.2.0".
11. Continue with configuration as desired.
Note Make sure you upgrade all 3.1.0 devices before removing the 3.1.0 version of the remote configuration manager. The remote configuration manager version must match that of the device. |
Use these instructions for installing the 3.2.0 remote configuration manager in Linux. Installing the 3.2.0 remote configuration manager will replace the 3.1.0 installation. If the 3.1.0 distribution CD is not in the CD drive, insert it now. Alternatively, use the appropriate path and file names if the 3.2.0 distribution directory has been downloaded onto the local file system. Enter the following commands at a Linux prompt:
mount -o map=off /mnt/cdrom
cd /mnt/cdrom/fw/Linux/i386
./install_cscacfg
Use these instructions for removing the 3.1.0 remote configuration manager and installing the 3.2.0 remote configuration manager in Solaris. If the 3.2.0 distribution CD is not in the CD drive, insert it now. Alternatively, use the appropriate path and file names if the 3.2.0 distribution directory has been downloaded onto the local file system.
1. Remove the previous installation with pkgrm.
2. Enter this command:
pkgadd -d /cdrom/cdrom0/fw/Solaris/Sparc
3. When the package is presented for installation, press Enter to install it.
4. Type q after installation to exit.
Use these instructions for removing the 3.1.0 remote configuration manager and installing the 3.2.0 remote configuration manager in Windows NT or Windows 2000.
1. Remove the 3.1.0 Configuration manager using Add/Remove Programs in the Control Panel.When the Install Shield Wizard opens, select the Remove option button and click Next. Follow the screen prompts as they are displayed.
2. If the 3.2.0 distribution CD is not in the CD drive, insert it now. Alternatively, use the appropriate icon, path, and file names if the 3.0.6 distribution directory has been downloaded onto the local file system.
3. Double-click the CD icon.
4. Double-click the MSWin icon.
5. Double-click the WinNT icon (Windows NT) or Win2K icon. (Windows 2000).
6. Double-click the setup.exe application icon.
7. Follow the displayed Install Shield instructions.
Follow these instructions for upgrading the device using a GUI management session.
1. Open a Web browser and connect to the Secure Content Accelerator.
2. Ensure that the General>Status page is displayed.
3. The Release panel should contain "3.1.0.N", where N is any number.
4. Click Tools to activate the Tools tabs.
5. Click the Firmware tab.
6. Type the path and firmware image file name or URL in the Upload Firmware text box, or click Browse and navigate to and select the firmware image file from the local file system.
7. Click Upload to load the firmware image into the GUI.
8. Click Install Image next to the file information in the Installable Firmware Images panel.
9. After the new firmware has uploaded, click the Restart tab.
10. Click Reboot to reload the device. Wait several minutes for the device to reboot.
11. Reconnect to the device using the GUI and the IP address assigned to it.
12. Click General to activate the General tabs.
13. The Release panel should contain "3.2.0".
14. Continue with configuration as desired.
The following sections contain information for using the new and updated features in the 3.2 firmware release.
The Secure URL Rewrite feature prevents URL redirects and references from breaking or circumventing SSL sessions. This example uses the CLI. The same options are available in the GUI.
Note The command line in the examples reflects using a serial management session. |
1. Open a management session with the device.
2. Enter Privileged, Configuration, and SSL Configuration modes:
SCA> enable
SCA# configure
(config[SCA])# ssl
(config-ssl[SCA])#
3. Enter Server Configuration mode for the server you wish to configure URL rewrites.
(config-ssl[SCA])# server myServer
(config-ssl-server[myServer])#
4. The urlrewrite command uses the following syntax:
urlrewrite <domainName> [sslport <portid>] [clearport <portid>] <redirectonly>
domainName | The domain or file identifier as a domain name, IP address, or path and file name. An * (asterisk) wild card character can be used to specify more than one server in a single domain, e.g., "*.company.com". |
sslport | Keyword identifying the specified port to be used for SSL traffic. |
portid | A port identification for SSL traffic. |
clearport | Keyword identifying the specific port to be used for clear text traffic. |
portid | A port identification for clear text traffic. |
redirectonly | A keyword is used to indicate that only the "Location:" field in the HTTP 30x redirect header should be rewritten. This solves a common problem with Web servers using insecure HTTP 30x redirects. |
(config-ssl-server[myServer])# urlrewrite www.mybusiness1.com sslport 443 clearport 81
http://www.mybusiness1.com:81
are rewritten to https://www.mybusiness1.com
. (config-ssl-server[myServer])# urlrewrite www.mybusiness2.com sslport 443 clearport 81 redirectonly
5. A wildcard can be used to specify multiple SSL hosts in the same domain.
(config-ssl-server[myServer])# urlrewrite *.mybusiness3.com sslport 443 clearport 81
Note Do not use *.com as a filter. The definition is too broad. |
6. To see the results of these URL rewrite rules in the server configuration, enter the following command. The results are presented below it.
(config-ssl-server[myServer])# show ssl server myServer
...
URL Rewrite:
Name Clear Port SSL Port Redirect Only
_________________________________________________________________________
www.mybusiness1.com 443 81 No
www.mybusiness2.com 443 81 Yes
*.mybusiness3.com 443 81 No
For more information about URL rewriting, contact your Cisco representative for a copy of the white paper SSL Offloaders and Contextual Consistency.
The 3.2 firmware upgrade offers additional SNTP capabilities, including allowing up to four SNTP servers.
Note To provide increased security, we recommend using an SNTP server on the internal network. Using an external SNTP server might compromise network security. |
1. Open a management session with the device.
2. Enter Privileged and Configuration modes:
SCA> enable
SCA# configure
(config[SCA])#
3. Enter the IP addresses or host names of up to four SNTP servers. (Host names are resolved to IP addresses in the device configuration.)
(config[SCA])# sntp server 10.1.24.2
(config[SCA])# sntp server 10.1.24.4
(config[SCA])# sntp server 10.2.22.2
(config[SCA])# sntp server 10.2.22.6
(config[SCA])#
4. The default polling interval is 86400 seconds (one day). To change this interval to 43200 seconds (12 hours), enter use the sntp interval command.
(config[SCA])# sntp interval 43200
(config[SCA])#
5. To view the results of these commands, you can use either the show sntp or show device command. The show sntp command and an example of returned information are below.
(config[SCA])# show sntp
SNTP server sources:
10.1.24.2 (0/6 fails/tries, stratum 2)
10.1.24.4 (0/0 fails/tries, stratum 2)
10.2.22.2 (0/0 fails/tries, stratum 2)
10.2.22.6 (0/0 fails/tries, stratum 2)
SNTP synchronization interval: 43200 (seconds)
(config[SCA])#
(config[SCA])# show device
...
SNTP sync'ing : every 43200 (s) from 10.1.24.2, 10.1.24.4, 10.2.22.2, 10.2.22.6
(0/6 fails/tries, stratum 2)
(0/0 fails/tries, stratum 2)
(0/0 fails/tries, stratum 2)
(0/0 fails/tries, stratum 2)
...
Any errors resulting from polling and synchronization are written to the syslog messages.
Time and date commands have been updated to be more consistent with other Cisco devices.
1. Open a serial or telnet management session with the device.
2. Enter Privileged and Configuration modes:
SCA> enable
SCA# configure
(config[SCA])#
3. Set the time by entering the following command. Press ENTER to accept the displayed time or type the new time and press ENTER.
(config[SCA])# clock time
Enter time [10:28:54]:
4. Set the date by entering the following command. Press ENTER to accept the displayed date or type in the new date and press ENTER.
(config[SCA])# clock date
Enter date [02-15-2002]:
Use the show date command to display the device date and time settings.
The Secure Content Accelerator can be connected to a terminal server, such as the Cisco 2511 Access Server. You will need a standard RJ45-DB9F adapter (CAB-9AS-FDTE, part number 74-0495-01).
1. Attach the RJ45-DB9F adapter to the CONSOLE port of the Secure Content Accelerator.
2. Using an octal cable with RJ45 connectors, attach the terminal server to the Secure Content Accelerator via the RJ45-DB9F adapter.
3. Using the line interface on the terminal server, use these commands:
line 1
autocommand connect
transport input all
Note If you are using firmware older than 3.0.5 on the Secure Content Accelerator, also use the command speed 115200. |
The 3.2 version can only be upgraded from 3.0 and later releases. Upgrading from other versions can fail or cause the loss of certain configuration parameters. The CD includes a 3.0.6 directory containing firmware images and remote configuration software necessary for the incremental update. Please see the section "Upgrading from Previous Releases" section.
Be aware that configurations for features not supported in 3.1 firmware cannot be used after the device has been downgraded. When the device reboots after downgrade, error messages might be displayed, reflecting unsupported portions of the configuration. These can be ignored safely.
We recommend using the serial console for downgrading the Secure Content Accelerator. Follow these instructions for downgrading using a serial management session.
1. Copy the firmware image to an HTTP, FTP, or TFTP server on the same LAN as the Secure Content Accelerator. An FTP URL is preferable.
2. Connect to the Secure Content Accelerator via a serial management session at 9,600 baud.
3. Check the existing firmware version using the show device command. The returned text should contain "MaxOS 3.2.0".
4. Enter these commands to load the firmware image, where protocol is HTTP, FTP, or TFTP; serverip is the IP address of the server; and path is the path to the firmware image file.
enable
copy to flash protocol://serverip/path/css-sca-2fe-k9.phz
reload
5. Wait for several minutes for the device to reload and reboot.
6. Reconnect to the Secure Content Accelerator.
7. Check the firmware version by using the show device command. The returned text should contain "MaxOS 3.1.0".
8. Continue with configuration as desired.
Follow these instructions for downgrading using a telnet management session.
1. Copy the firmware image to an HTTP, FTP, or TFTP server on the same LAN as the Secure Content Accelerator.
2. Connect to the Secure Content Accelerator using the IP address previously assigned to it.
3. If desired, save the running configuration for reloading following the downgrade using the copy running-configuration command. Enter the URL, including the protocol, for the configuration file when prompted. An FTP URL is preferable. An HTTP URL can only be used with a server that accept posts (PUT).
4. Check the existing firmware version using the show device command. The returned text should contain "MaxOS 3.2.0".
5. Enter these commands to load the firmware image, where prot is HTTP, FTP, or TFTP; serverip is the IP address of the server; and path is the path to the firmware image file.
enable
copy to flash prot://serverip/path/css-sca-2fe-k9.phz
reload
6. You will see a status message stating the connection to the device was lost. Wait for several minutes for the device to reload and reboot. The telnet connection to the device is lost.
7. Connect to the device using a serial or telnet management session.
8. Check the firmware version by using the show device command. The returned text should contain "MaxOS 3.1.0".
9. Continue with configuration as desired.
Follow these instructions for downgrading using a remote CLI management session.
1. Copy the firmware image to the computer from which you configure the Secure Content Accelerator.
2. Open the existing configuration manager application (cscacfg) using the desktop shortcut or the Start button (Windows) or entering cscacfg at a Unix or Linux prompt.
3. Display all Secure Content Accelerators found by the configuration manager by entering the show device list command. If the device is not listed, use the discover command.
4. The following commands assume only one device has been discovered by the configuration manager. If more than one Secure Content Accelerator is listed, use the on form of the command to specify the desired device.
Note You can set the on-prefix to direct commands to a single device. |
attach
enable
5. If only one Secure Content Accelerator is listed, use the show device command. If more than one device is listed, use the command on devname show device, where devname is the name of the device. The returned text should contain "MaxOS 3.2.0".
6. If desired, save the running configuration for reloading following the downgrade using the write file command. Enter the path and file name for the configuration file when prompted.
7. Enter these commands to load the firmware image, where path is the path to the firmware image file.
copy to flash path/css-sca-2fe-k9.phz
reload
8. Quit the configuration manager. If you wish to continue with configuration via the remote configuration manager, you must remove the 3.2 version and install the 3.1.0 version as described in "Remote Configuration Manager Replacement" below. Make sure you downgrade all 3.2.0 devices before removing the 3.2 version of the configuration manager.
9. To continue configuring the device with the 3.1.0 remote configuration manager, open the application (cscacfg) using the desktop short cut or the Start button (Windows) or entering cscacfg at a Unix or Linux prompt.
10. Display all Secure Content Accelerators found by the configuration manager by entering the show device list command. If the device is not listed, use the discover command.
11. Attach to the device and check the firmware version using the show device command. The returned text should contain "MaxOS version 3.1.0".
12. Continue with configuration as desired.
Note Make sure you downgrade all 3.1.0 devices before removing the 3.1.0 version of the remote configuration manager. |
Use these instructions for installing the 3.1.0 remote configuration manager in Linux. Installing the 3.1.0 remote configuration manager will replace the 3.2.0 installation. If the 3.2.0 distribution CD is not in the CD drive, insert it now. Alternatively, use the appropriate path and file names if the 3.1.0 distribution directory has been downloaded onto the local file system. Enter the following commands at a Linux prompt:
mount -o map=off /mnt/cdrom
cd /mnt/cdrom/310/Linux/i386
./install_cscacfg
Use these instructions for removing the 3.2.0 remote configuration manager and installing the 3.1.0 remote configuration manager in Solaris. If the 3.2.0 distribution CD is not in the CD drive, insert it now. Alternatively, use the appropriate path and file names if the 3.1.0 distribution directory has been downloaded onto the local file system.
1. Remove the previous installation with pkgrm.
2. Enter this command:
pkgadd -d /cdrom/cdrom0/310/Solaris/Sparc
3. When the package is presented for installation, press Enter to install it.
4. Type q after installation to exit.
Use these instructions for removing the 3.2.0 remote configuration manager and installing the 3.1.0 remote configuration manager in Windows NT or Windows 2000.
1. Remove the 3.2.0 Configuration manager using Add/Remove Programs in the Control Panel.When the Install Shield Wizard opens, select the Remove option button and click Next. Follow the screen prompts as they are displayed.
2. If the 3.2.0 distribution CD is not in the CD drive, insert it now. Alternatively, use the appropriate icon, path, and file names if the 3.1.0 distribution directory has been downloaded onto the local file system.
3. Double-click the CD icon.
4. Double-click the 310 icon.
5. Double-click the MSWin icon.
6. Double-click the WinNT icon (Windows NT) or Win2K icon. (Windows 2000).
7. Double-click the setup.exe application icon.
8. Follow the displayed Install Shield instructions.
Follow these instructions for downgrading using a GUI management session.
1. Open a Web browser and connect to the Secure Content Accelerator.
2. Ensure that the General>Status page is displayed.
3. The Release panel should contain "3.2.0.N", where N is any number.
4. If desired, save the running configuration for reloading following the downgrade using this procedure:
a. Click Tools to activate the Tools tabs.
b. Click the Preferences tab.
c. Right-click Download in the Running Configuration panel. Select either Save Target As... (Internet Explorer) or Save Link As... (Netscape) to save the configuration file.
5. Click Tools to activate the Tools tabs.
6. Click the Firmware tab.
7. Type the path and firmware image file name in the Upload Firmware text box, or click Browse and navigate to and select the firmware image file from the local file system.
8. Click Upload to load the firmware image into the GUI.
9. Click Install Image next to the file information in the Installable Firmware Images panel.
10. After the new firmware has uploaded, click the Restart tab.
11. Click Reboot to reload the device. Wait several minutes for the device to reboot.
12. Reconnect to the device using the GUI and the IP address assigned to it.
13. Click General to activate the General tabs.
14. The Release panel should contain "3.1.0".
15. Continue with configuration as desired.
access-list 10 permit 127.0.0.1 0.0.0.0
web-mgmt access-list 10
The factory-set default SNMP community is "public"; however, "public" is not listed in the configuration. The behavior of setting and resetting the SNMP community is demonstrated in the table below.
Command | SNMP community is set to... | SNMP community in configuration is... |
---|---|---|
snmp default community XYZ | XYZ | XYZ |
no snmp default community | XYZ | No default community listed |
snmp default community public | public | public |
The SSL device syslog implementation for firmware 3.2 and below supports only "kern" facility logging. A future release will offer "local" and custom facility support. The following are example syslogd.conf settings:
kern.debug; /var/log/ssl-debug
kern.info; /var/log/ssl-info
kern.none; /var/log/ssl-none
kern.crit; /var/log/ssl-crit
kern.warn; /var/log/ssl-warn
Or you can use the settings displayed below:
*.debug; /var/log/ssl-debug
*.info; /var/log/ssl-info
*.none; /var/log/ssl-none
*.crit; /var/log/ssl-crit
*.warn; /var/log/ssl-warn
In rare instances when using the Windows version of the configuration manager, resizing the window while doing a continuous display of statistics can cause an exception in the configuration manager.
Table 1 and Table 2 list CLI commands and options that have been added to or changed in version 3.2, respectively. Changed commands are listed in their current 3.2 format. Table 3 lists commands have been removed in this release. The command descriptions are a summary.
Mode | Command and Syntax | Description |
---|---|---|
Top Level Mode (Non-Privileged Mode) | show flows on <devname|groupname|all> show flows | Availability: Remote, Serial, Telnet Displays IP connection information for one or more devices. When using remote configuration, use the on form of the command to specify the target(s) of the command, where devname is the name of a single device, groupname is the name of a user-defined device group, and all represents all appropriate devices. Replaces the previous show flow command. |
Top Level Mode (Privileged Mode) | show diagnostic-report | Availability: Serial, Telnet Displays configuration and diagnostic information for a device. The reports shown are the following:
Individual reports can be generated using the command following each report name. |
| show sntp | Availability: Remote, Serial, Telnet Displays SNTP configuration information, including the SNTP servers configured and the polling interval. |
Configuration Mode | clock [date|time] | Availability: Serial Allows the administrator to set the date or time, respectively. After entering the command, you are prompted to enter the appropriate date or time. The device date and time can be viewed by using the show date command. |
| sntp interval [seconds] | Availability: Remote, Serial, Telnet Sets polling interval for all configured SNTP servers, where seconds is the number of seconds between polls. The default interval is 86400 seconds (one day), the minimum and maximum intervals are 60 and 2419200 (one month), respectively. The interval can be displayed using the commands show device, show snmp and write terminal. |
| sntp server [ipaddr|hostname] no sntp server [ipaddr|hostname]
| Availability: Remote, Serial, Telnet Sets or removes a specified SNTP server in the device configuration. You are prompted to enter and verify the password. Use the no form of the command to clear the SNTP server. If more than one SNTP server has been configured, you must specify the IP address or hostname of the one to delete. Up to four SNTP servers can be configured. If the first SNTP server returns an error, the next SNTP server is polled. After the fourth SNTP poll returns an error, the first server is polled again. SNTP information can be displayed using the commands show device, show snmp and write terminal. Note When a hostname is used rather than an IP address, the hostname is resolved as an IP address when written to the configuration. |
Server Configuration Mode | urlrewrite <domainName> [sslport <portid>] [clearport <portid>] <redirectonly> no urlrewrite <domainName> | Availability: Remote, Serial, Telnet Sets or remove a specified URL rewrite rule for the current secure server. The domainName is the domain or file identifier as a domain name, IP address, or path and file name. An * (asterisk) wild card character can be used to specify more than one server in a single domain, e.g., "*.company.com". The redirectonly keyword is used to indicate that only the "Location;" field in the HTTP 30x redirect header should be rewritten. This solves a common problem with Web servers using insecure HTTP 30x redirects. Up to 32 URL rewrite rules can be configured. Use the no form of the command to clear the specified rule. If more than one rule has been configured, you must specify the domain name of the rule to delete. URL rewrite information can be displayed by using the command show ssl server. |
Mode | Command and Syntax | Description |
---|---|---|
Configuration Mode | rdate-server [ipaddr|hostname] no rdate-server | Availability: Remote, Serial, Telnet Sets or removes a specified RDATE server in the device configuration. You are prompted to enter and verify the password. Use the no form of the command to clear the access- or enable-level password for the current device. Only one RDATE server can be configured. Note When a hostname is used rather than an IP address, the hostname is resolved as an IP address when written to the configuration. |
| sntp-server [ipaddr|hostname] no sntp-server [ipaddr|hostname]
| Availability: Remote, Serial, Telnet Sets or removes a specified SNTP server in the device configuration. You are prompted to enter and verify the password. Use the no form of the command to clear the access- or enable-level password for the current device. If more than one SNTP server has been configured, you must specify the IP address or hostname of the one to remove. Up to four SNTP servers can be configured. If the first SNTP server returns an error, the next SNTP server is polled. After the fourth SNTP poll returns an error, the first server is polled again. Note When a hostname is used rather than an IP address, the hostname is resolved as an IP address when written to the configuration. |
Mode | Command and Syntax | Description |
---|---|---|
Configuration Mode | show flow on <devname|groupname|all> show flow | Availability: Remote, Serial, Telnet Displays IP connection information for one or more devices. When using remote configuration, use the on form of the command to specify the target(s) of the command, where devname is the name of a single device, groupname is the name of a user-defined device group, and all represents all appropriate devices. |
| snmp trap-type enterprise ssl-cert-expire no snmp trap-type enterprise ssl-cert-expire | Availability: Remote, Serial, Telnet Specifies trapping for errors caused by expired certificates. Use the no form of the command to turn off SSL certificate expiration SNMP trapping. |
| snmp trap-type enterprise ssl-cert-invalid no snmp trap-type enterprise ssl-cert-invalid | Availability: Remote, Serial, Telnet Specifies trapping for errors caused by invalid certificates. Use the no form of the command to turn off SSL invalid certificate SNMP trapping. |
| snmp trap-type enterprise ssl-certify-failure no snmp trap-type enterprise ssl-certify-failure | Availability: Remote, Serial, Telnet Specifies trapping for errors caused by certificate authorization failures. Use the no form of the command to turn off SSL certificate authorization failure SNMP trapping. |
| snmp trap-type enterprise ssl-neg-failure no snmp trap-type enterprise ssl-neg-failure | Availability: Remote, Serial, Telnet Specifies trapping for SSL negotiation failures. Use the no form of the command to turn off SSL negotiation failure SNMP trapping. |
Server Configuration Mode | redirect | Availability: Remote, Serial, Telnet Enables server redirection. Use the no form of the command to disable server redirection. |
The following sections contain notes related to the 3.1 release.
The 3.1 version can only be upgraded from 3.0 and later releases. Upgrading from other versions can fail or cause the loss of certain configuration parameters. The CD includes a 306 directory containing firmware images and remote configuration software necessary for the incremental update. Before continuing with the upgrade, please read the notes below. To install the 3.0.6 version from a previous firmware release, see the file RelNot_306.pdf in the 306 directory of the distribution CD.
Table 4, below, presents device behaviors resulting from several upgrade scenarios as well as workarounds, if available.
Scenario | Result | Workaround |
---|---|---|
User-defined security policy "noexport56" is present. Reboot. | The user-defined security policy is over-written. | Recreate the existing user-defined security policy using a different name before updating the device. |
User-defined certificate group "defaultCA" is present. Reboot. | The user-defined certificate group is over-written. | Recreate the existing user-defined certificate group with a different name before updating the device. |
Prior to update, 251 user-defined security policies are present. | The security policy listed as index number 251 is deleted at reboot. | 1. Prior to updating, attach to the device using a CLI and use the show ssl command. 2. Look at the list in the Security Policies block. The Id 251 security policy is deleted at reboot. You can delete another security policy to preserve that one. 3. Identify the security policy used least. 4. Use the following commands to delete it. enable
configure
ssl
no secpolicy polname
Proceed with the update as instructed. |
Prior to update, 64 user-defined certificate groups are present. | The certificate group listed as index number 64 is deleted at reboot. | 1. Prior to updating, attach to the device using a CLI and use the show ssl command. 2. Look at the list in the Certificate Groups block. The Id 64 certificate group is lost when rebooting. You can delete another group to preserve that one. 3. Identify the certificate group used least. 4. Use the following commands to delete it. enable
configure
ssl
no certgroup certgpname
Proceed with the update as instructed. |
Prior to update, more than 495 user-defined certificates are present. | Certificates listed as index number 499 and above are deleted at reboot. | 1. Prior to updating, attach to the device using a CLI and use the show ssl command. 2. Look at the list in the Certificates block. Certificates listed as Id 499 and above are lost when rebooting. You can delete any less-used certificates to preserve the user-defined certificates listed as Id 499 and above. 3. Identify the certificates used least. 4. Use the following commands to delete each certificate. enable
configure
ssl
no cert certname
Proceed with the update as instructed. |
Devices flashed with version 3.1 firmware can be downgraded to version 3.0.6 firmware. The 310 directory contains an Adobe Acrobat file named DowngrdNote.pdf. This file has instructions for proceeding with the downgrade.
access-list 10 permit 127.0.0.1 0.0.0.0
web-mgmt access-list 10
Command | SNMP community is set to... | SNMP community in configuration is... |
---|---|---|
snmp default community XYZ | XYZ | XYZ |
no snmp default community | XYZ | No default community listed |
snmp default community public | public | public |
In rare instances when using the Windows version of the configuration manager, resizing the window while doing a continuous display of statistics can cause an exception in the configuration manager.
Table 5 and Table 6 list CLI commands and options that have been added or changed to software version 3.1. Changed commands are listed in their current 3.1 format. No commands have been removed in this release. The command descriptions are a summary. Please see the Cisco 11000 Series Secure Content Accelerator Configuration Guide for more information.
Mode | Command and Syntax | Description |
---|---|---|
Top Level: Non-Privileged and Privileged Modes
| monitor <command> on <devname|groupname|all> monitor <command> | Availability: Remote, Serial, Telnet Displays the results of the specified show command at one second intervals, where command is the command. When using remote configuration, use the on form of the command to specify the target(s) of the command, where devname is the name of a single device, groupname is the name of a user-defined device group, and all represents all appropriate devices. |
set monitor-interval <value> | Availability: Remote, Serial, Telnet Sets the number of seconds between monitor-prefixed command refreshes. Use the no form of the command to return the monitor interval to default value. | |
show flow on <devname|groupname|all> show flow | Availability: Remote, Serial, Telnet Displays IP connection information for one or more devices. When using remote configuration, use the on form of the command to specify the target(s) of the command, where devname is the name of a single device, groupname is the name of a user-defined device group, and all represents all appropriate devices. | |
show rdate-server on <devname|groupname|all> show rdate-server | Availability: Remote, Serial, Telnet Displays the IP address of the RDATE protocol server configuration for one or more devices. | |
show sntp-server on <devname|groupname|all> show sntp-server | Availability: Remote, Serial, Telnet Displays SNTP-server information for one or more devices. The SNTP server is used for date and time information. | |
show ssl session-stats [continuous] [interval <value>] on <devname|groupname|all> show ssl session-stats [continuous] [interval <value>] | Availability: Remote, Serial, Telnet Displays SSL session statistics summed over all secure logical servers on one or more devices. When using remote configuration, use the on form of the command to specify the target(s) of the command, where devname is the name of a single device, groupname is the name of a user-defined device group, and all represents all appropriate devices. | |
Top Level: Non-Privileged and Privileged Modes (continued) | show telnet on <devname|groupname|all> show telnet | Availability: Remote, Serial, Telnet Displays telnet management information for one or more devices. When using remote configuration, use the on form of the command to specify the target(s) of the command, where devname is the name of a single device, groupname is the name of a user-defined device group, and all represents all appropriate devices. |
show web-management on <devname|groupname|all> show web-management | Availability: Remote, Serial, Telnet Displays Web-based GUI management information for one or more devices. When using remote configuration, use the on form of the command to specify the target(s) of the command, where devname is the name of a single device, groupname is the name of a user-defined device group, and all represents all appropriate devices. | |
terminal baud <1200|2400|4800|9600|19200|38400|115200> | Availability: Serial Sets the baud for communicating with the Secure Content Accelerator. | |
Top Level: Privileged Mode | clear line <sessionId> | Availability: Serial Closes a specified management session, where sessionId is the session identifier. |
clear ssl session-stats on <devname|groupname|all> clear ssl session-stats | Availability: Remote, Serial, Telnet Resets all SSL session statistics for one or more devices. When using remote configuration, use the on form of the command to specify the target(s) of the command, where devname is the name of a single device, groupname is the name of a user-defined device group, and all represents all appropriate devices. | |
refresh | Availability: Remote, Serial, Telnet Updates device information in the configuration manager. | |
Group Configuration Mode | finished | Availability: Remote Exits Group Configuration Mode and returns to Top Level mode. |
Configuration Mode | finished | Availability: Remote, Serial, Telnet Leaves Configuration Mode and returns to Top Level mode. |
registration-code <code> | Availability: Remote, Serial, Telnet Stores the registration code of the device. | |
sntp-server <ipaddr> | Availability: Remote, Serial, Telnet Assigns an SNTP server, where ipaddr is the IP address of the server. Use the no form of the command to remove the SNTP server information. | |
Configuration Mode (continued) | telnet port <portid> | Availability: Remote, Serial, Telnet Specifies the TCP service port to use for telnet management sessions, where portid is the TCP service port to be used when managing the device via a telnet session. Use the no form of the command to return the telnet management port to the default setting. The port assignment is used at the next attach. |
web-mgmt port <portid> | Availability: Remote, Serial, Telnet Specifies the TCP service port used for management with the Web-based GUI, where portid is the TCP service port to be used when managing the device via the GUI. Use the no form of the command to return the GUI management port to the default setting. The port assignment is used at the next attach. | |
Interface Configuration Mode | finished | Availability: Remote, Serial, Telnet Leaves Interface Configuration Mode and returns to Top Level mode. |
SSL Configuration Mode | backend-server <servname> [create] | Availability: Remote, Serial, Telnet Creates and/or configures the specified backend server, where servname is the name of the server, and enters Backend Server Configuration mode for that server. The no form of the command is used to remove the specified backend server. A device can have a total of 255 servers in any combination of backend, reverse-proxy, or standard secure servers. |
finished | Availability: Remote, Serial, Telnet Leaves SSL Configuration Mode and returns to Top Level mode. | |
gencsr <key <keyname>> [newhdr] [digest md5|sha1] [output <filename|url>] | Availability: Remote, Serial, Telnet Generates a certificate signing request and/or self-signed certificate, where keyname is the name of the key to use for generation and filename and url are the location for the optional output file. | |
reverse-proxy-server <servname> [create] | Availability: Remote, Serial, Telnet Creates and/or configures the specified reverse-proxy server, where servname is the name of the server, and enters Reverse-Proxy Server Configuration mode for that server. The no form of the command is used to remove the specified reverse-proxy server. A device can have a total of 255 servers in any combination of backend, reverse-proxy, or standard secure servers. | |
Backend Server Configuration Mode | activate | Availability: Remote, Serial, Telnet Activates the current suspended backend server if enough information has been configured. |
certgroup serverauth <certgroupname> | Availability: Remote, Serial, Telnet Assigns a certificate group to be used for server certificate authentication, where certgroupname is the name of the existing certificate group. The no form of the command is used to disable server authentication using the certificate group. When using the no form of the command, you need not specify any certificate group name. Only one certificate group can be used. | |
end | Availability: Remote, Serial, Telnet Exits Backend Server Configuration mode, activates all changes, and returns to SSL Configuration mode. | |
exit | Availability: Remote, Serial, Telnet Exits Backend Server Configuration mode, activates all changes, and returns to SSL Configuration mode. | |
finished | Availability: Remote, Serial, Telnet Leaves Backend Server Configuration Mode and returns to Top Level mode. | |
help [command] | Availability: Remote, Serial, Telnet Displays help information for the specified command. If you do not specify a command, help information is displayed for all Backend Server Configuration Commands. | |
info | Availability: Remote, Serial, Telnet Displays current information about the logical secure server being edited or created. | |
ip address <ipaddr> [netmask <mask>] | Availability: Remote, Serial, Telnet Sets the specified IP address for the backend server, where ipaddr is the IP address and mask is the valid netmask. Using the no form of the command clears the IP address for the backend server. | |
localport <port|default> | Availability: Remote, Serial, Telnet Specifies the TCP service port through which non-secure connections are received, where port is the port specification. Using the keyword default sets the port specification to 80. | |
log-url <ipaddr> | Availability: Remote, Serial, Telnet Specifies a host for logging of URL requests, where ipaddr is the IP address of the log host. | |
Backend Server Configuration Mode (continued) | remoteport <port|default> | Availability: Remote, Serial, Telnet Specifies the TCP service port through which redirected secure connections are sent, where port is the port specification. Using the keyword default sets the port specification to 443. |
secpolicy <polname|all|default|strong|weak> | Availability: Remote, Serial, Telnet Creates an association between this server and the specified security policy, where polname is the name of the existing security policy. | |
serverauth enable | Availability: Remote, Serial, Telnet Enables server certificate authentication. Using the no form of the command disables server certificate authentication. | |
serverauth ignore all | none|signature-failure| expired-date|cert-not-yet-valid| invalid-ca|domain-name | Availability: Remote, Serial, Telnet Specifies the server authentication errors to ignore. Any combination of options can be used currently. Use the no form of the command to cease ignoring the specific server authentication error. | |
session-cache enable | Availability: Remote, Serial, Telnet Enables session caching. Use the no form of the command to disable session caching. | |
session-cache size <cachesize> | Availability: Remote, Serial, Telnet Specifies the size of the session cache, where cachesize is the number of sessions to be cached. The default is 1024. The acceptable range is 1 to 5096. | |
session-cache timeout <seconds> | Availability: Remote, Serial, Telnet Specifies the session cache length before being timed out, where seconds is the number of seconds before the cache times out. | |
suspend [now] | Availability: Remote, Serial, Telnet Suspends the function of the backend server. | |
transparent | Availability: Remote, Serial, Telnet Enables the backend server to function as a transparent proxy (default). When transparent proxy behavior is disabled, the device accepts connections on the IP address of the Secure Content Accelerator rather than on the server address. The no form of the command is used to disable this behavior. | |
Certificate Configuration Mode | finished | Availability: Remote, Serial, Telnet Leaves Certificate Configuration Mode and returns to Top Level mode. |
Certificate Group Configuration Mode | finished | Availability: Remote, Serial, Telnet Leaves Certificate Group Configuration Mode and returns to Top Level mode. |
Key Configuration Mode | finished | Availability: Remote, Serial, Telnet Leaves Key Configuration Mode and returns to Top Level mode. |
genrsa [bits <512|1024>] [encrypt <des|des3>] [seed <seedstring>] [output <filename|url>] | Availability: Remote, Serial, Telnet Generates an RSA key. | |
Reverse-Proxy Server Configuration Mode | activate | Availability: Remote, Serial, Telnet Activates the current suspended reverse-proxy server if enough information has been configured. |
certgroup serverauth <certgroupname> | Availability: Remote, Serial, Telnet Assigns a certificate group to be used for server certificate authentication, where certgroupname is the name of the existing certificate group. The no form of the command is used to disable server authentication using the certificate group. When using the no form of the command, you need not specify any certificate group name. Only one certificate group can be used. | |
end | Availability: Remote, Serial, Telnet Exits Reverse-Proxy Server Configuration mode, activates all changes, and returns to SSL Configuration mode. | |
exit | Availability: Remote, Serial, Telnet Exits Reverse-Proxy Server Configuration mode, activates all changes, and returns to SSL Configuration mode. | |
finished | Availability: Remote, Serial, Telnet Leaves Reverse-Proxy Server Configuration Mode and returns to Top Level mode. | |
help [command] | Availability: Remote, Serial, Telnet Displays help information for the specified command. If you do not specify a command, help information is displayed for all Reverse-Proxy Server Configuration Commands. | |
info | Availability: Remote, Serial, Telnet Displays current information about the logical secure server being edited or created. | |
ip address <ipaddr> [netmask <mask>] | Availability: Remote, Serial, Telnet Sets the specified IP address for the backend server, where ipaddr is the IP address and mask is the valid netmask. Using the no form of the command clears the IP address for the backend server. | |
Reverse-Proxy Server Configuration Mode (continued) | localport <port|default> | Availability: Remote, Serial, Telnet Specifies the TCP service port through which non-secure connections are received, where port is the port specification. Using the keyword default sets the port specification to 80. |
log-url <ipaddr> | Availability: Remote, Serial, Telnet Specifies a host for logging of URL requests, where ipaddr is the IP address of the log host. | |
remoteport <port|default> | Availability: Remote, Serial, Telnet Specifies the TCP service port through which redirected secure connections are sent, where port is the port specification. Using the keyword default sets the port specification to 443. | |
secpolicy <polname|all|default|strong|weak> | Availability: Remote, Serial, Telnet Creates an association between this server and the specified security policy, where polname is the name of the existing security policy. | |
serverauth enable | Availability: Remote, Serial, Telnet Enables server certificate authentication. Using the no form of the command disables server certificate authentication. | |
serverauth ignore all | none|signature-failure| expired-date|cert-not-yet-valid| invalid-ca|domain-name | Availability: Remote, Serial, Telnet Specifies the server authentication errors to ignore. Any combination of options can be used currently. Use the no form of the command to cease ignoring the specific server authentication error. | |
session-cache enable | Availability: Remote, Serial, Telnet Enables session caching. Use the no form of the command to disable session caching. | |
session-cache size <cachesize> | Availability: Remote, Serial, Telnet Specifies the size of the session cache, where cachesize is the number of sessions to be cached. The default is 1024. The acceptable range is 1 to 5096. | |
session-cache timeout <seconds> | Availability: Remote, Serial, Telnet Specifies the session cache length before being timed out, where seconds is the number of seconds before the cache times out. | |
suspend [now] | Availability: Remote, Serial, Telnet Suspends the function of the reverse-proxy server. | |
Security Policy Configuration Mode | finished | Availability: Remote, Serial, Telnet Leaves Security Policy Configuration Mode and returns to Top Level mode. |
Server Configuration Command Mode | activate | Availability: Remote, Serial, Telnet Activates the current logical secure server if enough information has been configured. |
certgroup clientauth <certgroupname> | Availability: Remote, Serial, Telnet Assigns a certificate group to be used as a certificate trust list for client certificate authentication. The no form of the command is used to disable client authentication using the certificate group. When using the no flag, you need not specify any certificate group name. Only one certificate chain can be used. | |
clientauth enable | Availability: Remote, Serial, Telnet Enables client certificate authentication. Use the no form of the command to disable client certificate authentication. | |
clientauth error <cert-not-provided| | Availability: Remote, Serial, Telnet Specifies the client certificate authentication errors to ignore. Any combination of options can be used currently. Use the no form of the command to cease ignoring the specific client authentication error. | |
clientauth verifydepth <depth> | Availability: Remote, Serial, Telnet Specifies the level of certificate within the certificate group to use when verifying client certificates, where depth is the number of certificates within the certificate group to use for authentication. | |
ephrsa | Availability: Remote, Serial, Telnet When an export browser version connects to a server using 1024-bit keys, this allows the RSA key exchange (the SSL handshake) to be negotiated using a dynamically created 512-bit key. Using ephemeral RSA ensures the device complies with United States commerce laws. The default is no ephemeral RSA. Use the no form of the command to disable ephemeral RSA. | |
finished | Availability: Remote, Serial, Telnet Leaves Server Configuration Mode and returns to Top Level mode. | |
Server Configuration Mode (continued) | httpheader <session|server-cert|client-cert| pre-filter|prefix <prefixString>> | Availability: Remote, Serial, Telnet Specifies the header information to pass to backend HTTP servers. Any combination of options can be used currently. Use the no form of the command to cease using the specific option. |
redirect | Availability: Remote, Serial, Telnet Enables server redirection. Use the no form of the command to disable server redirection. | |
session-cache enable | Availability: Remote, Serial, Telnet Enables session caching. Use the no form of the command to disable session caching. | |
session-cache size <cachesize> | Availability: Remote, Serial, Telnet Specifies the size of the session cache, where cachesize is the number of sessions. The default is 1024. The acceptable range is 1 to 5096. | |
session-cache timeout <seconds> | Availability: Remote, Serial, Telnet Specifies the session cache length before being timed out, where seconds is the number of seconds. | |
suspend [now] | Availability: Remote, Serial, Telnet Suspends the function of the server. |
Mode | Command and Syntax | Description |
---|---|---|
Top Level: Non-Privileged and Privileged Modes | show profile [all] | Availability: Remote Displays the monitor-interval and on-prefix settings of the if they have been changed from the default settings. |
Top Level: Privileged Mode | copy running-configuration [filename|url] on <devname> copy running-configuration [filename] | Availability: Remote, Serial, Telnet Writes the running-configuration of a device to a file. If you do not specify a file name or URL, you are prompted for it. When using remote configuration, use the on form of the command to specify the target(s) of the command, where devname is the name of a single device, groupname is the name of a user-defined device group, and all represents all appropriate devices. |
copy to flash [filename|url] on <devname> copy to flash [filename] | Availability: Remote, Serial, Telnet Uploads a Cisco Secure Content Accelerator image file to the device flash. If you do not specify a file name or URL, you are prompted for it. When using remote configuration, use the on form of the command to specify the target(s) of the command, where devname is the name of a single device, groupname is the name of a user-defined device group, and all represents all appropriate devices. | |
copy to running-configuration [filename|url] on <devname> copy to running-configuration [filename] | Availability: Remote, Serial, Telnet Uploads a saved configuration file and merges it to the running-configuration of a device. If you do not specify a file name or URL, you are prompted for it. When using remote configuration, use the on form of the command to specify the target(s) of the command, where devname is the name of a single device, groupname is the name of a user-defined device group, and all represents all appropriate devices. | |
Configuration Mode | password <access|enable> | Availability: Remote, Serial, Telnet Sets the access- or enable-level password for the current Secure Content Accelerator. You are prompted to enter and verify the password. Use the no form of the command to clear the access- or enable-level password for the current device. |
Backend Server Configuration Mode | secpolicy <polname|all|default| noexport56|strong|weak> | Availability: Remote, Serial, Telnet Creates an association between the backend server and the specified security policy. |
Reverse-Proxy Server Configuration Mode | secpolicy <polname|all|default| noexport56|strong|weak> | Availability: Remote, Serial, Telnet Creates an association between the reverse-proxy server and the specified security policy. |
Server Configuration Mode | secpolicy <polname|all|default| noexport56|strong|weak> | Availability: Remote, Serial, Telnet Creates an association between the server and the specified security policy. |
The 3.0 release of the Cisco Secure Content Accelerator firmware and software adds additional features and functionality. Changes to individual commands are noted in "Version 3.0 Command Changes".
The notes in this section apply to the Cisco CSS 11000 Secure Content Accelerator configuration manager application, version 3.0, for all operating systems.
%%timeout waiting for response to my challenge
%%Could not successfully attach to <device name>.
The notes in this section apply to the Cisco CSS 11000 Secure Content Accelerator configuration manager application, version 3.0, for RedHat Linux.
/mnt/cdrom/RedHat/RPMS/compat-libstdc++-6.2-2.9.0.9.i386.rpm
The notes in this section apply to the Cisco CSS 11000 Secure Content Accelerator configuration manager application, version 3.0, for Solaris.
a. Log in as root.
b. Enter cd /usr/lib
c. Enter ln -s libposix4.so.1 librt.so.1
In rare instances, resizing the window while doing a continuous display of statistics can cause an exception in the configuration manager.
Table 7 and Table 8 list CLI commands and options that have been added or changed to software version 3.0. Changed commands are listed in their current 3.0.5 format. Table 9 lists commands which have been removed in this release version. These descriptions are a summary. Please see the Cisco CSS 11000 Secure Content Accelerator Configuration Guide for more information.
Mode | Command and Syntax | Description |
---|---|---|
Top Level: Non-Privileged and Privileged Modes
| enable on <devname|groupname|all> enable | Availability: Remote, Serial, Telnet If an enable-level password has been defined, you must enter it when prompted. When using remote management, enters Privileged mode for a single, attached device. If more than one device is valid for this command, use the on form of the command to specify the device(s) to enable, where devname is the name of an individual device, groupname is the name of a user-defined group, and all represents all appropriate devices. Using the no form of this command leaves Privileged mode. |
group <groupname> [create] | Availability: Remote Use the create flag to create the specified group and enter Group Configuration mode for it, where groupname is the name of the device group. Use the no form of the command to remove the specified group. | |
paws | Availability: Remote, Serial, Telnet Pauses the configuration manager for a specified time or until a key is pressed. | |
set on-prefix <devname|groupname> | Availability: Remote Sets the target device(s) to address as default when using the on prefix, where devname is the name of a single device and groupname is the name of a user-defined device group. Use the no form of the command to clear the default entity. | |
show cpu [continuous] [interval <value>] on <devname|groupname|all> show cpu [continuous] [interval <value>] | Availability: Remote, Serial, Telnet Displays CPU utilization information for one or more devices. Use the continuous option to display statistics continuously, updated every second. Use the interval option to specify an interval for display updates, where value is the interval in seconds. Press any key to stop displaying statistics. When using remote configuration, use the on form of the command to specify the target(s) of the command, where devname is the name of a single device, groupname is the name of a user-defined device group, and all represents all appropriate devices. | |
show date | Availability: Serial, Telnet Displays current date and time settings on the device. | |
Top Level: Non-Privileged and Privileged Modes (continued) | show device list | Availability: Remote Displays summary information for all Secure Content Accelerators in the same broadcast domain as the configuring computer or found by the configuration manager through the discover or discover port commands. |
show dns on <devname|groupname|all> show dns | Availability: Remote, Serial, Telnet Displays DNS configuration information for one or more devices. When using remote configuration, use the on form of the command to specify the target(s) of the command, where devname is the name of a single device, groupname is the name of a user-defined device group, and all represents all appropriate devices. | |
show group [<groupname>] | Availability: Remote Displays group summary information for the specified group, where groupname is the name of the user-defined group. You must specify a group unless only one group is defined. | |
show ip domain-name on <devname|groupname|all> show ip domain-name | Availability: Remote, Serial, Telnet Displays DNS configuration information for one or more devices. When using remote configuration, use the on form of the command to specify the target(s) of the command, where devname is the name of a single device, groupname is the name of a user-defined device group, and all represents all appropriate devices. | |
show interface errors [<network | server>] [continuous] [interval <value>] on <devname|groupname|all> show interface errors [<network | server>] [continuous] [interval <value>] | Availability: Remote, Serial, Telnet Displays a listing of interface errors for one or more devices. If an interface is not specified, errors for both interfaces are displayed. If continuous is specified, error statistics are updated every second. Use the interval option to specify an interval for display updates, where value is the interval in seconds. Press any key to stop displaying errors. When using remote configuration, use the on form of the command to specify the target(s) of the command, where devname is the name of a single device, groupname is the name of a user-defined device group, and all represents all appropriate devices. | |
show ip name-server on <devname|groupname|all> show ip name-server | Availability: Remote, Serial, Telnet Displays DNS configuration information for one or more devices. When using remote configuration, use the on form of the command to specify the target(s) of the command, where devname is the name of a single device, groupname is the name of a user-defined device group, and all represents all appropriate devices. | |
show profile | Availability: Remote Displays current user preferences setting. | |
Top Level: Non-Privileged and Privileged Modes (continued) | show route on <devname|groupname|all> show route | Availability: Remote, Serial, Telnet Displays the routing table stored in one or more devices. When using remote configuration, use the on form of the command to specify the target(s) of the command, where devname is the name of a single device, groupname is the name of a user-defined device group, and all represents all appropriate devices. |
show sessions | Availability: Serial, Telnet Displays current remote, serial, and telnet management connections to the device. | |
show ssl key [<keyname>] on <devname|groupname|all> show ssl key [<keyname>] | Availability: Remote, Serial, Telnet Displays summary data for the specified public/private key pair loaded on one or more devices, where keyname is the name of the key. If you do not specify a key name, all key information is displayed. When using remote configuration, use the on form of the command to specify the target(s) of the command, where devname is the name of a single device, groupname is the name of a user-defined device group, and all represents all appropriate devices. | |
terminal length | Availability: Remote, Serial, Telnet Sets the number of lines in a terminal window. | |
terminal width <width> | Availability: Remote, Serial, Telnet Sets the width of the terminal window. | |
Top Level: Privileged Mode | clear interface statistics on <devname|groupname|all> clear interface statistics | Availability: Remote, Serial, Telnet Resets all interface statistics for one or more devices. When using remote configuration, use the on form of the command to specify the target(s) of the command, where devname is the name of a single device, groupname is the name of a user-defined device group, and all represents all appropriate devices. |
clear ip routes on <devname|groupname|all> clear ip routes | Availability: Remote, Serial, Telnet Clears the IP routing table on one or more devices. When using remote configuration, use the on form of the command to specify the target(s) of the command, where devname is the name of a single device, groupname is the name of a user-defined device group, and all represents all appropriate devices. | |
clear ip statistics on <devname|groupname|all> clear ip statistics | Availability: Remote, Serial, Telnet Resets all IP statistics on one or more devices. When using remote configuration, use the on form of the command to specify the target(s) of the command, where devname is the name of a single device, groupname is the name of a user-defined device group, and all represents all appropriate devices. | |
Top Level: Privileged Mode (continued) | copy running-configuration [<filename>] on <devname> copy running-configuration [<filename>] | Availability: Remote Writes the running-configuration of a device. If you do not specify a file name, you are prompted for it. When using remote configuration, use the on form of the command to specify the target of the command, where devname is the device name. |
copy running-configuration <url> | Availability: Serial, Telnet Writes the running-configuration of a device to a file, where url is the name of the file. | |
copy running-configuration startup-configuration | Availability: Serial, Telnet Writes the running-configuration of a device to its startup-configuration. | |
copy startup-configuration <url> | Availability: Serial, Telnet Writes the startup-configuration of a device to a file, where url is the name of the file. | |
copy startup-configuration running-configuration | Availability: Serial, Telnet Writes the startup-configuration of a device to its running-configuration. | |
copy to flash <url> | Availability: Serial, Telnet Uploads a Cisco Secure Content Accelerator image file to the device flash, where url is the name of the file. | |
copy to flash [<filename>] on <devname|groupname|all> copy to flash [<filename>] | Availability: Remote Uploads a Cisco Secure Content Accelerator image file to the device flash. If you do not specify a file name, you are prompted for it. When using remote configuration, use the on form of the command to specify the target(s) of the command, where devname is the name of a single device, groupname is the name of a user-defined device group, and all represents all appropriate devices. | |
copy to running-configuration [<filename>] on <devname> copy to running-configuration [<filename>] | Availability: Remote Uploads a saved configuration file to the device flash. If you do not specify a file name, you are prompted for it. When using remote configuration, use the on form of the command to specify the target of the command, where devname is the device name. | |
copy to running-configuration <url> | Availability: Serial, Telnet Uploads a saved configuration file and merges it to the running-configuration of a device, where url is the file name. | |
Top Level: Privileged Mode (continued) | copy to startup-configuration <url> | Availability: Serial, Telnet Uploads a saved configuration file and merges it to the startup-configuration of a device, where url is the file name. |
disable on <devname|groupname|all> disable | Availability: Remote, Serial, Telnet Exits Privileged mode for one or more devices. When using remote configuration, use the on form of the command to specify the target(s) of the command, where devname is the name of a single device, groupname is the name of a user-defined device group, and all represents all appropriate devices. | |
erase running-configuration on <devname|groupname|all> erase running-configuration | Availability: Remote, Serial, Telnet Erases the running-configuration on one or more devices. When using remote configuration, use the on form of the command to specify the target(s) of the command, where devname is the name of a single device, groupname is the name of a user-defined device group, and all represents all appropriate devices. | |
erase startup-configuration on <devname|groupname|all> erase startup-configuration | Availability: Remote, Serial, Telnet Erases the startup-configuration on one or more devices. When using remote configuration, use the on form of the command to specify the target(s) of the command, where devname is the name of a single device, groupname is the name of a user-defined device group, and all represents all appropriate devices | |
show startup-configuration | Availability: Serial, Telnet Displays the startup-configuration of a device. | |
write memory | Availability: Serial, Telnet Writes the running-configuration to flash memory on a device. | |
write network <url> | Availability: Serial, Telnet Writes the running-configuration to a file on a remote host, where url is the name of the file. | |
Group Configuration Mode | device <devname> | Availability: Remote Adds the specified device to the group list, where devname is the name of the device. |
end | Availability: Remote Leaves Group Configuration Mode. | |
exit | Availability: Remote Leaves Group Configuration Mode. | |
help [<command>] | Availability: Remote Displays information for a specific command, where command is the name of the command. If no command is specified, help information is displayed for all Group Configuration commands. | |
Group Configuration Mode (continued) | info | Availability: Remote Displays current information about the device group being created or edited. |
Configuration Mode | exit | Availability: Remote, Serial, Telnet Leaves Configuration Mode and returns to Privileged Mode. |
ip domain-name <name> | Availability: Remote, Serial, Telnet Sets the default domain name for the device, where name is the domain name. | |
ip name-server <ipaddr> | Availability: Remote, Serial, Telnet Sets the one or more name servers to use with the device, where ipaddr is the IP address of the Domain Name Server. | |
mode one-port | Availability: Serial Enables secure and non-secure traffic to pass through the single "Network" Ethernet port. Use the no form of the command to return the device to dual-port mode.
| |
mode pass-thru | Availability: Remote, Serial, Telnet Enables pass through of non-SSL traffic. Pass through is the default. Use the no form of the command to block non-SSL traffic pass through. | |
rdate-server <ipaddr> | Availability: Remote, Serial, Telnet Specifies and RDATE-protocol server to be used for date and time information on the device, where ipaddr is the IP address of the RDATE server. | |
remote-management shared-secret <passphrase> | Availability: Serial Sets the secret passphrase used for encryption, where passphrase is the passphrase. Use the no form of the command to clear the passphrase. | |
telnet access-list <id> | Availability: Remote, Serial, Telnet Assigns an existing access list to be used with telnet management requests, where id is the access list identifier. Use the no form of the command to remove the specified access list. | |
telnet enable | Availability: Remote, Serial, Telnet Allows telnet management sessions for the device. Use the no form of the command to disable telnet management access | |
timezone <zone> | Availability: Serial, Telnet Specifies the time zone of the device's location, where zone is the time zone identifier. | |
Configuration Mode (continued) | web-mgmt access-list <id> | Availability: Remote, Serial, Telnet Assigns an existing access list to be used with web browser-based management requests, where id is the access list identifier. Use the no form of the command to remove the specified access list. |
web-mgmt enable | Availability: Remote, Serial, Telnet Allows web browser-based management sessions for the device. Use the no form of the command to disable web browser-based management access. | |
SSL Configuration Mode | import pkcs12 <name> [<filename>]|<url> | Availability: Remote, Serial, Telnet Imports and processes a pkcs12-format file to create certificate and key objects, where name is the user-defined name for the certificate and key objects, filename is the path and name of the file, and url is the location of the file (serial and telnet only). |
import pkcs7 <name> <der|pem> [prefix <prefixText>] [<filename>]|<url> | Availability: Remote, Serial, Telnet Imports and processes a pkcs7-format file to create a certificate object, where name is the user-defined name of the certificate group object, prefixText is the prefix assigned to the certificate names in the chain, filename is the path and name of the file, and url is the location of the file (serial and telnet only). You must specify whether the file is encoded in DER or PEM format and identify a prefix, if any. | |
key <keyname> [create] | Availability: Remote, Serial, Telnet Creates and/or configures the specified key object, where keyname is the name of the key and enters Key Configuration mode for the specified key. The create flag is used to create a new key. The no flag is used to remove a key. You may not delete a key referenced by a server. You can have up to 255 key objects. | |
Certificate Configuration Mode | binhex [<value>] | Availability: Remote, Serial, Telnet Allows a binary hex-encoded X509 certificate to be pasted into the configuration manager. After the command is entered, you are prompted to paste the key from the cut buffer. You can use a text editor to copy the key from a file. After the key is pasted, you must press Enter twice to complete the command. |
exit | Availability: Remote, Serial, Telnet Exits Certificate Configuration mode, activates all valid changes, and returns to SSL Configuration mode. | |
Certificate Group Configuration Mode | exit | Availability: Remote, Serial, Telnet Exits Certificate Group Configuration mode, activates all changes, and returns to SSL Configuration mode. |
Key Configuration Mode | binhex [<value>] | Availability: Remote, Serial, Telnet Allows a binary hex-encoded key to be pasted into the configuration manager. After the command is entered, you are prompted to paste the key from the cut buffer. You can use a text editor to copy the key from a file. After the key is pasted, you must press Enter twice to complete the command. |
Security Policy Configuration Mode | exit | Availability: Remote, Serial, Telnet Exits Security Policy Configuration mode, activates all changes, and returns to SSL Configuration mode. |
Server Configuration Command Set | cert <certname | default | default-1024 | default 512> | Availability: Remote, Serial, Telnet Sets the specified certificate for use by the server. Only one certificate is allowed per server. If you enter this command with a different certificate, that reference replaces the earlier one. |
exit | Availability: Remote, Serial, Telnet Exits Server Configuration mode, activates all changes, and returns to SSL Configuration mode. | |
key <keyname | default | default-1024 | default 512> | Availability: Remote, Serial, Telnet Sets the specified key for use by the server. Only one key is allowed per server. If you enter this command with a different key, that reference replaces the earlier one. | |
log-url <ipaddr> | Availability: Remote, Serial, Telnet Specifies a host for logging of URL requests, where ipaddr is the IP address of the host. |
Mode | Command and Syntax | Description |
---|---|---|
Top Level: Non-Privileged and Privileged Modes | attach on <devname|groupname|all> attach | Availability: Remote Instructs the configuration manager to attach to one or more devices. Use the no form of the command to detach the configuration manager from one or more devices. If an access-level password has been defined, you must enter it when prompted before the configuration manager will attach to the device(s). If a shared secret passphrase has been assigned as part of remote management encryption, you are prompted for it. If more than one device is valid for this command, use the on form of the command to specify the device(s) to attach to or detach from (using the no form of the command), where devname is the name of an individual device, groupname is the name of a user-defined group, and all represents all appropriate devices. |
discover [port <portid>] | Availability: Remote Checks the network for new remote devices. Use the port option to specify a TCP service port to search for devices when using an alternate remote management port, where portid is the port number. | |
exit | Availability: Remote, Serial, Telnet Quits the configuration manager. When executed from the remote configuration manager, closes the configuration manager. When executed from a serial connection, does not close the connection. If an access password has been configured, you are prompted for it. When executed from telnet, closes the telnet connection. | |
quit | Availability: Remote, Serial, Telnet Quits the configuration manager. When executed from the remote configuration manager, closes the configuration manager. When executed from a serial connection, does not close the connection. If an access password has been configured, you are prompted for it. When executed from telnet, closes the telnet connection. | |
show arp | Availability: Remote, Serial, Telnet Displays the arp device cache on a single device. When using remote configuration, use the on form of the command to specify the target(s) of the command, where devname is the name of a single device, groupname is the name of a user-defined device group, and all represents all appropriate devices. | |
show device | Availability: Remote, Serial, Telnet Displays device information for one or more devices. When using remote configuration, use the on form of the command to specify the target(s) of the command, where devname is the name of a single device, groupname is the name of a user-defined device group, and all represents all appropriate devices. | |
Top Level: Non-Privileged and Privileged Modes (continued) | show interface [network | server] on <devname|groupname|all> show interface [network | server] | Availability: Remote, Serial, Telnet Displays information for the specified Ethernet interface for one or more devices. The information includes connection, duplex, speed, and autonegotiation settings. You must specify a device name unless only one Secure Content Accelerator is attached. If you do not specify network or server, information for all interfaces on the specified device is displayed. When using remote configuration, use the on form of the command to specify the target(s) of the command, where devname is the name of a single device, groupname is the name of a user-defined device group, and all represents all appropriate devices. |
show interface statistics [<network | server>] [continuous] [interval <value>] on <devname|groupname|all> show interface statistics [<network | server>] [continuous] [interval <value>] | Availability: Remote, Serial, Telnet Displays interface statistics for one or more devices. If an interface is not specified, statistics for both interfaces are displayed. If continuous is specified, statistics are updated every second. Use the interval option to specify an interval for display updates, where value is the interval in seconds. Press any key to stop displaying statistics. When using remote configuration, use the on form of the command to specify the target(s) of the command, where devname is the name of a single device, groupname is the name of a user-defined device group, and all represents all appropriate devices. | |
show ip routes on <devname|groupname|all> show ip routes | Availability: Remote, Serial, Telnet Displays the routing table for one or more devices. When using remote configuration, use the on form of the command to specify the target(s) of the command, where devname is the name of a single device, groupname is the name of a user-defined device group, and all represents all appropriate devices. | |
show ip statistics on <devname|groupname|all> show ip statistics | Availability: Remote, Serial, Telnet Displays diagnostic IP, ICMP, TCP, and UDP statistics for one or more devices. When using remote configuration, use the on form of the command to specify the target(s) of the command, where devname is the name of a single device, groupname is the name of a user-defined device group, and all represents all appropriate devices. | |
show keepalive-monitor on <devname|groupname|all> show keepalive-monitor | Availability: Remote, Serial, Telnet Displays a list of keepalive-monitor IP addresses for one or more devices. SSL errors from IP addresses specified with the keepalive-monitor command are ignored. When using remote configuration, use the on form of the command to specify the target(s) of the command, where devname is the name of a single device, groupname is the name of a user-defined device group, and all represents all appropriate devices. | |
Top Level: Non-Privileged and Privileged Modes (continued) | show memory [zones] on <devname|groupname|all> show memory [zones] | Availability: Remote, Serial, Telnet Displays memory usage on one or more devices. The zones flag is used to display information for each memory zone. When using remote configuration, use the on form of the command to specify the target(s) of the command, where devname is the name of a single device, groupname is the name of a user-defined device group, and all represents all appropriate devices. |
show messages on <devname|groupname|all> show messages | Availability: Remote, Serial, Telnet Displays the diagnostic message buffer for one or more devices. When using remote configuration, use the on form of the command to specify the target(s) of the command, where devname is the name of a single device, groupname is the name of a user-defined device group, and all represents all appropriate devices. | |
show netstat on <devname|groupname|all> show netstat | Availability: Remote, Serial, Telnet Displays the current state of the IP connection for one or more devices. When using remote configuration, use the on form of the command to specify the target(s) of the command, where devname is the name of a single device, groupname is the name of a user-defined device group, and all represents all appropriate devices. | |
show processes on <devname|groupname|all> show processes | Availability: Remote, Serial, Telnet Displays information, by thread, about processes running on one or more devices. When using remote configuration, use the on form of the command to specify the target(s) of the command, where devname is the name of a single device, groupname is the name of a user-defined device group, and all represents all appropriate devices. | |
show remote-management on <devname|groupname|all> show remote-management | Availability: Remote, Serial, Telnet Displays remote management information for one or more devices. When using remote configuration, use the on form of the command to specify the target(s) of the command, where devname is the name of a single device, groupname is the name of a user-defined device group, and all represents all appropriate devices. | |
show rip on <devname|groupname|all> show rip | Availability: Remote, Serial, Telnet Displays the RIP status of one or more devices. When using remote configuration, use the on form of the command to specify the target(s) of the command, where devname is the name of a single device, groupname is the name of a user-defined device group, and all represents all appropriate devices. | |
Top Level: Non-Privileged and Privileged Modes (continued) | show snmp on <devname|groupname|all> show snmp | Availability: Remote, Serial, Telnet Displays SNMP configuration information for one or more devices. When using remote configuration, use the on form of the command to specify the target(s) of the command, where devname is the name of a single device, groupname is the name of a user-defined device group, and all represents all appropriate devices. |
show ssl on <devname|groupname|all> show ssl | Availability: Remote, Serial, Telnet Displays SSL summary data for one or more devices. When using remote configuration, use the on form of the command to specify the target(s) of the command, where devname is the name of a single device, groupname is the name of a user-defined device group, and all represents all appropriate devices. | |
show ssl cert [<certname>] on <devname|groupname|all> show ssl cert [<certname>] | Availability: Remote, Serial, Telnet Displays summary data for the specified certificate entity loaded on one or more devices, where certname is the name of the certificate. If you do not specify a certificate entity name, all certificate entity information is displayed. When using remote configuration, use the on form of the command to specify the target(s) of the command, where devname is the name of a single device, groupname is the name of a user-defined device group, and all represents all appropriate devices. | |
show ssl certgroup [<certgroupname>] on <devname|groupname|all> show ssl certgroup [<certgroupname>] | Availability: Remote, Serial, Telnet Displays summary data for a certificate group loaded on one or more devices, where certgroupname is the name of the certificate group. If you do not specify a certificate group, all certificate group information is displayed. When using remote configuration, use the on form of the command to specify the target(s) of the command, where devname is the name of a single device, groupname is the name of a user-defined device group, and all represents all appropriate devices. | |
show ssl errors [continuous] [interval <value>] on <devname|groupname|all> show ssl errors [continuous] [interval <value>] | Availability: Remote, Serial, Telnet Displays SSL errors reported on one or more devices. Use the continuous option to update the statistics every second. Use the interval option to specify an interval for display updates, where value is the interval in seconds. Press any key to stop displaying errors. When using remote configuration, use the on form of the command to specify the target(s) of the command, where devname is the name of a single device, groupname is the name of a user-defined device group, and all represents all appropriate devices. | |
Top Level: Non-Privileged and Privileged Modes (continued) | show ssl secpolicy [<polname>] on <devname|groupname|all> show ssl secpolicy [<polname>] | Availability: Remote, Serial, Telnet Displays summary data for the specified security policy on one or more devices. When using remote configuration, use the on form of the command to specify the target(s) of the command, where devname is the name of a single device, groupname is the name of a user-defined device group, and all represents all appropriate devices. |
show ssl server [<servname>] | Availability: Remote, Serial, Telnet Displays information for the specified configured logical secure server on one or more devices, where servname is the name of the logical secure server. If you do not specify a secure server name, all secure server information is displayed. When using remote configuration, use the on form of the command to specify the target(s) of the command, where devname is the name of a single device, groupname is the name of a user-defined device group, and all represents all appropriate devices. | |
show ssl statistics [continuous] [interval <value>] on <devname|groupname|all> show ssl statistics [continuous] [interval <value>] | Availability: Remote, Serial, Telnet Displays SSL statistics summed over all secure logical servers on one or more devices. Use the continuous option to update the statistics every second. Use the interval option to specify an interval for display updates. Press any key to stop displaying information. When using remote configuration, use the on form of the command to specify the target(s) of the command, where devname is the name of a single device, groupname is the name of a user-defined device group, and all represents all appropriate devices. | |
show syslog on <devname|groupname|all> show syslog | Availability: Remote, Serial, Telnet Displays the list of hosts to which diagnostic messages from one or more devices are sent. When using remote configuration, use the on form of the command to specify the target(s) of the command, where devname is the name of a single device, groupname is the name of a user-defined device group, and all represents all appropriate devices. | |
show system-resources [continuous] [interval <value>] on <devname|groupname|all> show system-resources [continuous] [interval <value>] | Availability: Remote, Serial, Telnet Displays system memory and CPU usage for one or more devices. Use the continuous option to update the information every second. Use the interval option to specify an interval for display updates, where value is the interval in seconds. Press any key to stop displaying information. When using remote configuration, use the on form of the command to specify the target(s) of the command, where devname is the name of a single device, groupname is the name of a user-defined device group, and all represents all appropriate devices. | |
Top Level: Non-Privileged and Privileged Mode (continued) | traceroute <ipaddr|name> | Availability: Remote, Serial, Telnet Displays the router hops to the specified destination, where ipaddr is the IP address of the destination and name is the host name (serial/telnet only). |
Top Level: Privileged Mode | clear messages on <devname|groupname|all> clear messages | Availability: Remote, Serial, Telnet Empties the diagnostic message buffer on one or more devices. When using remote configuration, use the on form of the command to specify the target(s) of the command, where devname is the name of a single device, groupname is the name of a user-defined device group, and all represents all appropriate devices. |
clear ssl statistics on <devname|groupname|all> clear ssl statistics | Availability: Remote, Serial, Telnet Resets all SSL statistics for one or more devices. When using remote configuration, use the on form of the command to specify the target(s) of the command, where devname is the name of a single device, groupname is the name of a user-defined device group, and all represents all appropriate devices. | |
quick-start on <devname> quick-start | Availability: Remote, Serial, Telnet Runs the QuickStart wizard for a device. You must specify a device unless only one device is appropriate. When using remote configuration, use the on form of the command to specify the target of the command, where devname is the name of a single device. | |
reload on <devname|groupname|all> reload
| Availability: Remote, Serial, Telnet Reboots one or more devices. You must specify a device unless only one device is appropriate. When using remote configuration, use the on form of the command to specify the target(s) of the command, where devname is the name of a single device, groupname is the name of a user-defined device group, and all represents all appropriate devices. | |
show access-list [<listid>] on <devname|groupname|all> show access-list [<listid>] | Availability: Remote, Serial, Telnet Displays the specified access list for one or more devices, where listid is the access list identifier. If you do not specify an access list identifier, information for all access lists is displayed. When using remote configuration, use the on form of the command to specify the target(s) of the command, where devname is the name of a single device, groupname is the name of a user-defined device group, and all represents all appropriate devices. | |
Top Level: Privileged Mode (continued) | show running-configuration on <devname|groupname|all> show running-configuration | Availability: Remote, Serial, Telnet Displays the running-configuration on one or more devices. When using remote configuration, use the on form of the command to specify the target(s) of the command, where devname is the name of a single device, groupname is the name of a user-defined device group, and all represents all appropriate devices. |
write file [<filename>] on <devname> write file [<filename>] | Availability: Remote Writes the running-configuration of a device to a file on the file system of the configuring computer, where filename is the name and path of the file. When using remote configuration, use the on form of the command to specify the target of the command, where devname is the name of a single device. | |
write flash on <devname|groupname|all> write flash | Availability: Remote, Serial, Telnet Writes the running-configuration to flash memory on one or more devices. When using remote configuration, use the on form of the command to specify the target(s) of the command, where devname is the name of a single device, groupname is the name of a user-defined device group, and all represents all appropriate devices. | |
write messages [<filename>] on <devname> write messages [<filename>] | Availability: Remote Writes the diagnostic messages of a device to a file, where filename is the name and path of the file. If you do not supply a file name, you are prompted for it. When using remote configuration, use the on form of the command to specify the target of the command, where devname is the name of a single device. | |
write terminal on <devname|groupname|all> write terminal | Availability: Remote, Serial, Telnet Displays the running-configuration of one or more devices. When using remote configuration, use the on form of the command to specify the target(s) of the command, where devname is the name of a single device, groupname is the name of a user-defined device group, and all represents all appropriate devices. | |
Configuration Mode | password <access|enable> | Availability: Remote, Serial, Telnet Sets the access- or enable-level password for the current Secure Content Accelerator. You are prompted to enter the password. Use the no form of the command to clear the access- or enable-level password for the current device. |
Certificate Configuration Mode | der [<cert-filename>]|<url> | Availability: Remote, Serial, Telnet Loads a DER-encoded X509 certificate into the certificate entity, where cert-filename is the name of the file and url is the location of the file (serial and telnet only). If you do not enter the file name, you are prompted for it. You must enter the path if the file is not located in the current directory. |
pem [<cert-filename>]|<url> | Availability: Remote, Serial, Telnet Loads a PEM-encoded certificate into the certificate entity, where cert-filename is the name of the key file and url is the location of the file (serial and telnet only). If you do not enter the file name, you are prompted for it. You must enter the path if the file is not located in the current directory. | |
Key Configuration Mode (was Key Association Configuration Mode) | der [<key-filename>]|<url> | Availability: Remote, Serial, Telnet Loads a DER-encoded X509 private key into the key entity, where key-filename is the name of the file and url is the location of the file (serial and telnet only). If you do not enter the file name, you are prompted for it. You must enter the path if the file is not located in the current directory. |
exit | Availability: Remote, Serial, Telnet Exits Key Configuration mode, activates all changes, and returns to SSL Configuration mode. | |
net-iis [<key-filename>]|<url> | Availability: Remote, Serial, Telnet Loads a private key exported from IIS4 into the key entity, where key-filename is the name of the key file and url is the location of the file (serial and telnet only). You must enter a private key password. If you do not enter the file name, you are prompted for it. You must enter the path if the file is not located in the current directory. | |
pem [<key-filename>]|<url> | Availability: Remote, Serial, Telnet Loads a PEM-encoded X509 private key into the key object, where key-filename is the path and name of the file and url is the location of the file (serial and telnet only). If you do not enter the file names, you are prompted for them. Key names cannot contain spaces and must be compatible with the configuring computer's operating system. You must enter the path if the file is not located in the current directory. | |
Server Configuration Mode | sslport <port|default> | Availability: Remote, Serial, Telnet Specifies the TCP service port to which non-secure connections is sent, where port is the port number. Use the default argument to return to the default setting of 443. |
Mode | Command and Syntax | Description |
---|---|---|
Top Level | attach all | Instructs the configuration manager to attach all non-attached remote devices on the network. Use the no form of the command to detach the configuration manager from all remote devices on the network. |
copy file configuration [devname] | Loads a saved configuration for use as the active configuration for the device. | |
copy file flash [devname] | Updates a flash image on the specified device based upon the specified flash image file. | |
copy file flash all | Updates all flash images on all attached devices. | |
erase flash [devname] | Erases the configuration stored in the flash memory of the specified device. | |
erase flash all | Erases the configuration stored in the flash memory on all attached devices. | |
erase memory [devname] | Erases the configuration running on the specified device but does not erase the configuration stored in the flash memory. | |
reload all | Reboots all attached configuration-level devices. | |
show access-lists [devname] | Displays all defined access lists for a specified device. | |
show configuration [devname] | Displays the active configuration for the specified device. | |
show devices | Displays a list of all Secure Content Accelerator devices. | |
show routes [devname] | Displays the routing table stored in the device, where devname is the name of the device. | |
show ssl errors all [continuous] | Displays SSL errors for all attached Secure Content Accelerator devices. | |
show ssl keyassoc [keyname] | Displays summary data for the specified public/private key pair loaded on the device. | |
show ssl statistics all [continuous] | Displays SSL statistics summed over all secure logical servers on all attached Secure Content Accelerator devices. | |
su [devname] | Raises the security level on the specified attach-level device. Using the no form of the command lowers the security level on the specified config-level device. | |
su all | Raises the security level on all attach-level devices. Using the no form of the command lowers the security level on all config-level devices. | |
write flash all | Writes the active configuration to flash memory on all attached devices. | |
SSL Configuration Mode | keyassoc <keyname> [create] | Creates and/or configures the specified key association and enters Key Association Configuration mode for the specified key association. The no form of the command is used to remove a key association. |
mode one-port | Prompts the administrator to use the serial console to switch operation of the Secure Content Accelerator to use a single Ethernet port for both secure SSL traffic and non-secure clear or plain text traffic. | |
mode pass-thru | Enables pass-through of non-SSL traffic. This is the default behavior. Use the no form of the command to disable pass-through. | |
Key Association Configuration Mode | cert <der|pem> [<cert-filename>] | Loads a X509 certificate file in the specified file format. |
cert pem-paste | Allows a PEM-encoded X509 certificate to be pasted into the configuration manager. | |
key <der | netiis | pem> [<key-filename>] | Loads a key file in the specified file format. | |
key pem-paste | Allows a PEM-encoded key to be pasted into the configuration manager. | |
Server Configuration Mode | keyassoc <keyassocname> | Creates an association between this logical secure server and the specified key association. |
CCIP, the Cisco Powered Network mark, the Cisco Systems Verified logo, Cisco Unity, Fast Step, Follow Me Browsing, FormShare, Internet Quotient, iQ Breakthrough, iQ Expertise, iQ FastTrack, the iQ Logo, iQ Net Readiness Scorecard, Networking Academy, ScriptShare, SMARTnet, TransPath, and Voice LAN are trademarks of Cisco Systems, Inc.; Changing the Way We Work, Live, Play, and Learn, Discover All That's Possible, The Fastest Way to Increase Your Internet Quotient, and iQuick Study are service marks of Cisco Systems, Inc.; and Aironet, ASIST, BPX, Catalyst, CCDA, CCDP, CCIE, CCNA, CCNP, Cisco, the Cisco Certified Internetwork Expert logo, Cisco IOS, the Cisco IOS logo, Cisco Press, Cisco Systems, Cisco Systems Capital, the Cisco Systems logo, Empowering the Internet Generation, Enterprise/Solver, EtherChannel, EtherSwitch, GigaStack, IOS, IP/TV, LightStream, MGX, MICA, the Networkers logo, Network Registrar, Packet, PIX, Post-Routing, Pre-Routing, RateMUX, Registrar, SlideCast, StrataView Plus, Stratm, SwitchProbe, TeleRouter, and VCO are registered trademarks of Cisco Systems, Inc. and/or its affiliates in the U.S. and certain other countries.
All other trademarks mentioned in this document or Web site are the property of their respective owners. The use of the word partner does not imply a partnership relationship between Cisco and any other company. (0201R)
Copyright © 2002, Cisco Systems, Inc.
All rights reserved.
Posted: Mon Aug 19 22:13:39 PDT 2002
All contents are Copyright © 1992--2002 Cisco Systems, Inc. All rights reserved.
Important Notices and Privacy Statement.